Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Circulation ; 2024 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-39051104

RESUMO

BACKGROUND: Whether vigorous exercise increases risk of ventricular arrhythmias for individuals diagnosed and treated for congenital long-QT syndrome (LQTS) remains unknown. METHODS: The National Institutes of Health-funded LIVE-LQTS study (Lifestyle and Exercise in Genetic Cardiovascular Conditions) prospectively enrolled individuals 8 to 60 years of age with phenotypic or genotypic LQTS from 37 sites in 5 countries from May 2015 to February 2019. Participants (or parents) answered physical activity and clinical events surveys every 6 months for 3 years with follow-up completed in February 2022. Vigorous exercise was defined as ≥6 metabolic equivalents for >60 hours per year. A blinded Clinical Events Committee adjudicated the composite end point of sudden death, sudden cardiac arrest, ventricular arrhythmia treated by an implantable cardioverter defibrillator, and likely arrhythmic syncope. A National Death Index search ascertained vital status for those with incomplete follow-up. A noninferiority hypothesis (boundary of 1.5) between vigorous exercisers and others was tested with multivariable Cox regression analysis. RESULTS: Among the 1413 participants (13% <18 years of age, 35% 18-25 years of age, 67% female, 25% with implantable cardioverter defibrillators, 90% genotype positive, and 49% with LQT1), 91% were treated with beta-blockers, left cardiac sympathetic denervation, or implantable cardioverter defibrillator; 52% participated in vigorous exercise (55% competitively). Thirty-seven individuals experienced the composite end point (including one sudden cardiac arrest and one sudden death in the nonvigorous group, one sudden cardiac arrest in the vigorous group) with overall event rates at 3 years of 2.6% in the vigorous and 2.7% in the nonvigorous exercise groups. The unadjusted hazard ratio for experience of events for the vigorous group compared with the nonvigorous group was 0.97 (90% CI, 0.57-1.67), with an adjusted hazard ratio of 1.17 (90% CI, 0.67-2.04). The upper 95% one-sided confidence level extended beyond the 1.5 boundary. Neither vigorous or nonvigorous exercise was found to be superior in any group or subgroup. CONCLUSIONS: Among individuals diagnosed with phenotypic or genotypic LQTS who were risk assessed and treated in experienced centers, LQTS-associated cardiac event rates were low and similar between those exercising vigorously and those not exercising vigorously. Consistent with the low event rate, CIs are wide, and noninferiority was not demonstrated. These data further inform shared decision-making discussions between patient and physician about exercise and competitive sports participation. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02549664.

2.
N Engl J Med ; 370(18): 1694-701, 2014 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-24678999

RESUMO

BACKGROUND: The Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy (MADIT-CRT) showed that early intervention with cardiac-resynchronization therapy with a defibrillator (CRT-D) in patients with an electrocardiographic pattern showing left bundle-branch block was associated with a significant reduction in heart-failure events over a median follow-up of 2.4 years, as compared with defibrillator therapy alone. METHODS: We evaluated the effect of CRT-D on long-term survival in the MADIT-CRT population. Post-trial follow-up over a median period of 5.6 years was assessed among all 1691 surviving patients (phase 1) and subsequently among 854 patients who were enrolled in post-trial registries (phase 2). All reported analyses were performed on an intention-to-treat basis. RESULTS: At 7 years of follow-up after initial enrollment, the cumulative rate of death from any cause among patients with left bundle-branch block was 18% among patients randomly assigned to CRT-D, as compared with 29% among those randomly assigned to defibrillator therapy alone (adjusted hazard ratio in the CRT-D group, 0.59; 95% confidence interval [CI], 0.43 to 0.80; P<0.001). The long-term survival benefit of CRT-D in patients with left bundle-branch block did not differ significantly according to sex, cause of cardiomyopathy, or QRS duration. In contrast, CRT-D was not associated with any clinical benefit and possibly with harm in patients without left bundle-branch block (adjusted hazard ratio for death from any cause, 1.57; 95% CI, 1.03 to 2.39; P=0.04; P<0.001 for interaction of treatment with QRS morphologic findings). CONCLUSIONS: Our findings indicate that in patients with mild heart-failure symptoms, left ventricular dysfunction, and left bundle-branch block, early intervention with CRT-D was associated with a significant long-term survival benefit. (Funded by Boston Scientific; ClinicalTrials.gov numbers, NCT00180271, NCT01294449, and NCT02060110.).


Assuntos
Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Idoso , Bloqueio de Ramo/complicações , Terapia Combinada , Desfibriladores Implantáveis , Feminino , Seguimentos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/prevenção & controle , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Índice de Gravidade de Doença , Volume Sistólico , Disfunção Ventricular Esquerda/complicações
3.
N Engl J Med ; 367(24): 2275-83, 2012 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-23131066

RESUMO

BACKGROUND: The implantable cardioverter-defibrillator (ICD) is highly effective in reducing mortality among patients at risk for fatal arrhythmias, but inappropriate ICD activations are frequent, with potential adverse effects. METHODS: We randomly assigned 1500 patients with a primary-prevention indication to receive an ICD with one of three programming configurations. The primary objective was to determine whether programmed high-rate therapy (with a 2.5-second delay before the initiation of therapy at a heart rate of ≥200 beats per minute) or delayed therapy (with a 60-second delay at 170 to 199 beats per minute, a 12-second delay at 200 to 249 beats per minute, and a 2.5-second delay at ≥250 beats per minute) was associated with a decrease in the number of patients with a first occurrence of inappropriate antitachycardia pacing or shocks, as compared with conventional programming (with a 2.5-second delay at 170 to 199 beats per minute and a 1.0-second delay at ≥200 beats per minute). RESULTS: During an average follow-up of 1.4 years, high-rate therapy and delayed ICD therapy, as compared with conventional device programming, were associated with reductions in a first occurrence of inappropriate therapy (hazard ratio with high-rate therapy vs. conventional therapy, 0.21; 95% confidence interval [CI], 0.13 to 0.34; P<0.001; hazard ratio with delayed therapy vs. conventional therapy, 0.24; 95% CI, 0.15 to 0.40; P<0.001) and reductions in all-cause mortality (hazard ratio with high-rate therapy vs. conventional therapy, 0.45; 95% CI, 0.24 to 0.85; P=0.01; hazard ratio with delayed therapy vs. conventional therapy, 0.56; 95% CI, 0.30 to 1.02; P=0.06). There were no significant differences in procedure-related adverse events among the three treatment groups. CONCLUSIONS: Programming of ICD therapies for tachyarrhythmias of 200 beats per minute or higher or with a prolonged delay in therapy at 170 beats per minute or higher, as compared with conventional programming, was associated with reductions in inappropriate therapy and all-cause mortality during long-term follow-up. (Funded by Boston Scientific; MADIT-RIT ClinicalTrials.gov number, NCT00947310.).


Assuntos
Desfibriladores Implantáveis , Taquicardia/terapia , Idoso , Desfibriladores Implantáveis/efeitos adversos , Desenho de Equipamento , Falha de Equipamento , Feminino , Seguimentos , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Taquicardia/diagnóstico , Taquicardia/mortalidade , Fatores de Tempo
4.
Europace ; 16(7): 1007-14, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24446509

RESUMO

AIMS: The step-wise approach to catheter ablation for persistent atrial fibrillation (AF) requires considerable substrate modification targeting at complex fractionated atrial electrograms (CFAEs) in addition to pulmonary vein (PV) isolation. An alternative strategy that minimizes the amount of ablation would be desirable. The aim of this study was to investigate whether the use of pre-procedural amiodarone affects: (i) the amount of ablation required to achieve procedural success, and (ii) long-term outcomes. METHODS AND RESULTS: We studied 121 consecutive patients with persistent AF who underwent catheter ablation. The patients were divided into two groups: Group 1, amiodarone (n = 31); Group 2, other antiarrhythmic drugs or rate control (n = 90). All the patients underwent a step-wise ablation procedure beginning with PV isolation, then proceeding with ablation of the CFAEs and linear lesions until sinus rhythm was achieved. Mean left atrial cycle length of AF (AFCL) was recorded at each step. The number of CFAE ablation sites was recorded. The number of CFAE sites in Group 1 was significantly less than that in Group 2 (P = 0.0121). The AFCLs after each step in Group 1 were significantly longer than those in Group 2. The procedure time and the radiofrequency time of CFAE ablation in Group 1 were significantly shorter than that in Group 2 (P = 0.0276 and P = 0.0458, respectively). There was no significant difference between the two groups in early and long-term outcomes. CONCLUSION: Use of pre-procedural amiodarone prolongs AFCL during catheter ablation and reduces the number of CFAE sites requiring ablation to achieve procedural success while maintaining equivalent long-term results.


Assuntos
Amiodarona/uso terapêutico , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/terapia , Ablação por Cateter , Duração da Cirurgia , Veias Pulmonares/efeitos dos fármacos , Idoso , Amiodarona/efeitos adversos , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Terapia Combinada , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
6.
N Engl J Med ; 361(14): 1329-38, 2009 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-19723701

RESUMO

BACKGROUND: This trial was designed to determine whether cardiac-resynchronization therapy (CRT) with biventricular pacing would reduce the risk of death or heart-failure events in patients with mild cardiac symptoms, a reduced ejection fraction, and a wide QRS complex. METHODS: During a 4.5-year period, we enrolled and followed 1820 patients with ischemic or nonischemic cardiomyopathy, an ejection fraction of 30% or less, a QRS duration of 130 msec or more, and New York Heart Association class I or II symptoms. Patients were randomly assigned in a 3:2 ratio to receive CRT plus an implantable cardioverter-defibrillator (ICD) (1089 patients) or an ICD alone (731 patients). The primary end point was death from any cause or a nonfatal heart-failure event (whichever came first). Heart-failure events were diagnosed by physicians who were aware of the treatment assignments, but they were adjudicated by a committee that was unaware of assignments. RESULTS: During an average follow-up of 2.4 years, the primary end point occurred in 187 of 1089 patients in the CRT-ICD group (17.2%) and 185 of 731 patients in the ICD-only group (25.3%) (hazard ratio in the CRT-ICD group, 0.66; 95% confidence interval [CI], 0.52 to 0.84; P=0.001). The benefit did not differ significantly between patients with ischemic cardiomyopathy and those with nonischemic cardiomyopathy. The superiority of CRT was driven by a 41% reduction in the risk of heart-failure events, a finding that was evident primarily in a prespecified subgroup of patients with a QRS duration of 150 msec or more. CRT was associated with a significant reduction in left ventricular volumes and improvement in the ejection fraction. There was no significant difference between the two groups in the overall risk of death, with a 3% annual mortality rate in each treatment group. Serious adverse events were infrequent in the two groups. CONCLUSIONS: CRT combined with ICD decreased the risk of heart-failure events in relatively asymptomatic patients with a low ejection fraction and wide QRS complex. (ClinicalTrials.gov number, NCT00180271.)


Assuntos
Estimulação Cardíaca Artificial , Cardioversão Elétrica , Insuficiência Cardíaca/terapia , Idoso , Desfibriladores Implantáveis , Intervalo Livre de Doença , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Volume Sistólico
7.
J Cardiovasc Electrophysiol ; 22(7): 822-4, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21159011

RESUMO

INTRODUCTION: With the increasing number of patients undergoing repeat catheter ablation procedures for atrial fibrillation, it is not uncommon to encounter a fibrotic interatrial septum that resists the conventional manual advancement of the transseptal sheath. Forceful advancement of the transseptal apparatus can reduce fine control and potentially lead to a higher rate of perforation. CASE: We report a case where adjunctive balloon atrial septostomy was used to facilitate transseptal access in a patient with fibrotic interatrial septum. Using a small-caliber angioplasty balloon and under direct fluoroscopic and transesophageal echocardiogram visualization, balloon septostomy was performed with hand inflation until a "waist" was seen. This technique provides a safe way to control the size of the transseptal access created, and allows the passage of a relatively soft-tipped transseptal sheath across a resistive septum. To our knowledge this is the first published use of balloon atrial septostomy during transseptal puncture for left atrium access in a catheter ablation procedure. CONCLUSION: Balloon atrial septostomy should be considered as an alternative technique for safe transseptal cannulation in select patients in the electrophysiology laboratory or other interventional procedures requiring left atrial access or delivery of large-caliber catheters or sheaths.


Assuntos
Angioplastia Coronária com Balão/estatística & dados numéricos , Fibrilação Atrial/terapia , Septo Interatrial , Ablação por Cateter , Fibrilação Atrial/fisiopatologia , Septo Interatrial/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade
8.
J Cardiovasc Electrophysiol ; 22(8): 892-7, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21831163

RESUMO

BACKGROUND: Elderly patients comprise a large portion of patients with heart failure (HF). Limited data exist on the effectiveness of cardiac resynchronization therapy with defibrillator (CRT-D) in patients with mild HF symptoms in this population. METHODS AND RESULTS: The benefit of CRT-D compared with ICD-only therapy in reducing HF or death was assessed by age categories (prespecified as <60 [n = 548], 60-74 [n = 941], and ≥75 [n = 331] years) among 1,820 patients in MADIT-CRT. In patients with ICD-only, there was a graded age-related increase in the Kaplan-Meier cumulative probability of HF or death at 3-year follow-up (19%, 33%, and 36%, in patients aged <60, 60-74, and ≥75 years, respectively, P = 0.003). Multivariate analysis demonstrated that CRT-D therapy was associated with a significant reduction in the risks of HF or death in patients aged 60-74, and ≥75 years (HR = 0.57, P = <0.001 and HR = 0.59, P = 0.017, respectively), and no significant benefit in patients aged <60 years (HR = 0.81, P = 0.3; P-value for all treatment-by-age interactions >0.10). There was no significant difference in the rate of device-related adverse events within 90 days following CRT-D implantation among age-subgroups (16.7%, 15.7%, and 11.7%, in patients <60, 60-74, and ≥75 years, respectively, P = 0.42). CONCLUSION: CRT-D was associated with a significant clinical benefit in older patients (≥60 years) during an average 2.4-year follow-up. These effects were preserved for the elderly patients ≥75 years of age but attenuated in patients <60 years. Elderly patients had no increase in device-related adverse events compared with younger patients.


Assuntos
Terapia de Ressincronização Cardíaca/tendências , Cardiomiopatias/prevenção & controle , Cardiomiopatias/fisiopatologia , Prevenção Secundária , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Cardiomiopatias/terapia , Cardioversão Elétrica/tendências , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
9.
Pacing Clin Electrophysiol ; 34(1): 15-22, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21029137

RESUMO

BACKGROUND: The relationship between the applied techniques and clinical outcomes after radiofrequency (RF) ablation of atrial fibrillation (AF) remains unclear. We compared the results of ablation by RF delivered via a point-by-point versus catheter dragging technique for the treatment of AF. METHODS: This study included 66 patients with drug-refractory AF who underwent circumferential pulmonary vein (PV) ablation. A point-by-point technique was used in 35 (53%) patients (Group I), and catheter dragging technique in the remaining 31 (47%) patients (Group II). If AF persisted or remained inducible after the PV isolation, additional ablation of complex fractionated atrial electrograms and linear ablation were performed. RESULTS: Significantly, fewer RF applications were delivered in Group II than in Group I. The total RF energy duration delivered was comparable between the two groups (P = 0.55). However, the total energy of RF deliveries was significantly greater in Group II than in Group I (P = 0.02). Despite a longer fluoroscopic exposure time (P = 0.01), the total procedural duration was significantly shorter in Group II than in Group I (P = 0.005). Within 3 months after a single ablation procedure, 24 patients (69%) in Group I versus 13 patients (42%) in Group II had ≥1 recurrence(s) of atrial tachyarrhythmias (P = 0.03). A multivariate analysis showed that a point-by-point ablation was the only independent predictor of early atrial tachyarrhythmia recurrences. CONCLUSIONS: The catheter dragging technique for ablation of AF was associated with a lower early recurrence rate of atrial tachyarrhythmias than the point-by-point technique.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Adulto Jovem
10.
J Am Heart Assoc ; 10(17): e021002, 2021 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-34398691

RESUMO

Background Recently there has been increased interest in a possible association between mast cell activation (MCA) disorder and postural orthostatic tachycardia syndrome (POTS). This study examined the frequency with which symptoms and laboratory findings suggesting MCA disorder occurred in patients diagnosed with POTS. Methods and Results Data were obtained from patients in whom symptoms and orthostatic testing were consistent with a POTS diagnosis. Individuals with <4 months symptom duration, evident ongoing inflammatory disease, suspected volume depletion, or declined consent were excluded. All patients had typical POTS symptoms; some, however, had additional nonorthostatic complaints not usually associated with POTS. The latter patients underwent additional testing for known MCA biochemical mediators including prostaglandins, histamine, methylhistamine, and plasma tryptase. The study comprised 69 patients who met POTS diagnostic criteria. In 44 patients (44/69, 64%) additional nonorthostatic symptoms included migraine, allergic complaints, skin rash, or gastrointestinal symptoms. Of these 44 patients, 29 (66%) exhibited at least 1 laboratory abnormality suggesting MCA disorder, and 11/29 patients had 2 or more such abnormalities. Elevated prostaglandins (n=16) or plasma histamine markers (n=23) were the most frequent findings. Thus, 42% (29/69) of patients initially diagnosed with POTS exhibited both additional symptoms and at least 1 elevated biochemical marker suggesting MCA disorder. Conclusions Laboratory findings suggesting MCA disorder were relatively common in patients diagnosed with POTS and who present with additional nonorthostatic gastrointestinal, cutaneous, and allergic symptoms. While solitary abnormal laboratory findings are not definitive, they favor MCA disorder being considered in such cases.


Assuntos
Transtornos da Ativação de Mastócitos , Síndrome da Taquicardia Postural Ortostática , Gastroenteropatias , Histamina/sangue , Humanos , Transtornos da Ativação de Mastócitos/epidemiologia , Síndrome da Taquicardia Postural Ortostática/epidemiologia , Prostaglandinas/sangue
11.
Eur J Cardiovasc Prev Rehabil ; 17(5): 607-12, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20461006

RESUMO

This article is a report of an international symposium, endorsed by the Section on Sports Cardiology of the European Association for Cardiovascular Prevention and Rehabilitation, the Italian Society of Sports Cardiology, and the Italian Federation of Sports Medicine, which was held within the 11th International Workshop on Cardiac Arrhythmias (Venice Arrhythmias 2009, Venice, Italy, October 2009). The following main topics were discussed during the symposium: the role of novel diagnostic examinations to assess the risk of sudden death in athletes, controversies on arrhythmic risk evaluation in athletes, controversies on the relationship between sports and arrhythmias, and controversies on antiarrhythmic treatment in athletes.


Assuntos
Arritmias Cardíacas/etiologia , Morte Súbita Cardíaca/etiologia , Esportes , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Humanos , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco
14.
Circ Arrhythm Electrophysiol ; 11(11): e006305, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30520349

RESUMO

BACKGROUND: Despite safety concerns, many young patients with implantable cardioverter-defibrillators (ICDs) participate in sports. We undertook a prospective, multinational registry to determine the incidence of serious adverse events because of sports participation. The primary end points were death or resuscitated arrest during sports or injury during sports because of arrhythmia or shock. Secondary end points included system malfunction and incidence of ventricular arrhythmias requiring multiple shocks for termination. METHODS: Athletes with ICDs aged ≤21 years were included in this post hoc subanalysis of the ICD Sports Registry. Data on sports and clinical outcomes were obtained by phone interview and medical records review. ICD shocks and clinical details of lead malfunction were classified by 2 electrophysiologists. RESULTS: A total of 129 young athletes participating in competitive (n=117) or dangerous (n=12) sports were enrolled. The mean age was 16 years (range, 10-21; 40% female; 92% white). The most common diagnoses were long QT syndrome (n=49), hypertrophic cardiomyopathy (n=30), and congenital heart disease (n=16). The most common sports were basketball and soccer, including 79 varsity/junior varsity high school and college athletes. During a median follow-up of 42 months, 35 athletes (27%) received 38 shocks. There were no occurrences of death, arrest, or injury related to arrhythmia, during sports. There was 1 ventricular tachycardia/ventricular fibrillation storm during competition. Freedom from lead malfunction was 92.3% at 5 years and 79.6% at 10 years. CONCLUSIONS: Although shocks related to competition/practice are not uncommon, there were no serious adverse sequelae. Lead malfunction rates were similar to previously reported in unselected pediatric ICD populations. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT00637754.


Assuntos
Atletas , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Cardiopatias/fisiopatologia , Cardiopatias/terapia , Segurança do Paciente , Esportes , Adolescente , Criança , Falha de Equipamento , Feminino , Humanos , Masculino , Estudos Prospectivos , Sistema de Registros , Prevenção Secundária , Adulto Jovem
15.
Circulation ; 113(24): 2810-7, 2006 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-16769917

RESUMO

BACKGROUND: Implantable cardioverter-defibrillator (ICD) therapy may be associated with an increased risk for heart failure (HF). The present study evaluated the frequency, causes, and consequences of HF after ICD implantation. METHODS AND RESULTS: We performed a retrospective analysis of the clinical factors and outcomes associated with postenrollment HF events in 1218 patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial II. The adjusted hazard ratios (HRs) of ICD:conventional therapy for first and recurrent HF events were 1.39 (P=0.02) and 1.58 (P<0.001), respectively. The risk was increased among patients who received single-chamber or dual-chamber ICDs. Development of HF was associated with an increased mortality risk (HR, 3.80; P<0.001). Among patients who received a single-chamber ICD, there was a similar survival benefit before and after the development of HF (HR, 0.59 and 0.61, respectively; P=0.92 for difference), whereas among patients with dual-chamber devices, there was a significant reduction in survival benefit after HF (HR, 0.26 and 0.83, respectively; P=0.01 for difference). Within the defibrillator arm of the trial, patients who received life-prolonging therapy from the ICD had an increased risk for first and recurrent HF events (HR, 1.90; P=0.01 and 1.74; P<0.001, respectively). CONCLUSIONS: Patients with chronic ischemic heart disease who are treated with either single-chamber or dual-chamber ICDs have improved survival but an increased risk of HF. The present data suggest that ICD therapy transforms sudden death risk to a subsequent HF risk. These findings should direct more attention to the prevention of HF in patients who receive an ICD.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Insuficiência Cardíaca/etiologia , Antagonistas Adrenérgicos beta/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Causas de Morte , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/classificação , Desenho de Equipamento , Feminino , Insuficiência Cardíaca/epidemiologia , Humanos , Tábuas de Vida , Masculino , Pessoa de Meia-Idade , Mortalidade , Infarto do Miocárdio/terapia , Modelos de Riscos Proporcionais , Recidiva , Estudos Retrospectivos , Risco , Análise de Sobrevida
18.
N Engl J Med ; 346(12): 877-83, 2002 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-11907286

RESUMO

BACKGROUND: Patients with reduced left ventricular function after myocardial infarction are at risk for life-threatening ventricular arrhythmias. This randomized trial was designed to evaluate the effect of an implantable defibrillator on survival in such patients. METHODS: Over the course of four years, we enrolled 1232 patients with a prior myocardial infarction and a left ventricular ejection fraction of 0.30 or less. Patients were randomly assigned in a 3:2 ratio to receive an implantable defibrillator (742 patients) or conventional medical therapy (490 patients). Invasive electrophysiological testing for risk stratification was not required. Death from any cause was the end point. RESULTS: The clinical characteristics at base line and the prevalence of medication use at the time of the last follow-up visit were similar in the two treatment groups. During an average follow-up of 20 months, the mortality rates were 19.8 percent in the conventional-therapy group and 14.2 percent in the defibrillator group. The hazard ratio for the risk of death from any cause in the defibrillator group as compared with the conventional-therapy group was 0.69 (95 percent confidence interval, 0.51 to 0.93; P=0.016). The effect of defibrillator therapy on survival was similar in subgroup analyses stratified according to age, sex, ejection fraction, New York Heart Association class, and the QRS interval. CONCLUSIONS: In patients with a prior myocardial infarction and advanced left ventricular dysfunction, prophylactic implantation of a defibrillator improves survival and should be considered as a recommended therapy.


Assuntos
Arritmias Cardíacas/prevenção & controle , Desfibriladores Implantáveis , Infarto do Miocárdio/terapia , Disfunção Ventricular Esquerda/terapia , Antagonistas Adrenérgicos beta/uso terapêutico , Idoso , Amiodarona/uso terapêutico , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Antiarrítmicos/uso terapêutico , Arritmias Cardíacas/etiologia , Terapia Combinada , Desfibriladores Implantáveis/efeitos adversos , Feminino , Humanos , Hipolipemiantes/uso terapêutico , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/fisiopatologia , Modelos de Riscos Proporcionais , Volume Sistólico , Análise de Sobrevida , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/mortalidade
20.
J Cardiovasc Electrophysiol ; 18(1): 41-6, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17229299

RESUMO

INTRODUCTION: Fibrillatory rates can reliably be obtained from surface ECGs during atrial fibrillation (AF) and correspond with right atrial (RA) and coronary sinus (CS) rates, while both the relation with pulmonary venous (PV) rates and determinants of fibrillatory waveform are unknown. Class III antiarrhythmic drugs prolong atrial refractoriness and decrease its dispersion, effects that may be reflected in ECG parameters. Consequently, this study sought (1) to investigate the relation between ECG fibrillatory rate and waveform characteristics with intraatrial/PV fibrillatory activity and (2) to noninvasively monitor class III antiarrhythmic drug effects in patients with AF. METHODS AND RESULTS: Thirty-six patients with drug-refractory AF who underwent catheter-based pulmonary vein isolation and had AF at the beginning of the procedure were studied. A positive correlation between V1 rates obtained by time-frequency analysis and RA (R = 0.97, P < 0.001), CS (R = .71, P < 0.001), and PV rates (R = 0.65, P = 0.001) was found. Exponential decay defined as decay of the curve that connects power maxima of dominant and harmonic frequency components correlated with RA rate dispersion (R = 0.53, P = 0.004). In amiodarone-treated patients (n = 7), V1 rate (286 +/- 64 vs. 371 +/- 40 fpm, P < 0.001) and exponential decay (1.06 +/- 0.29 vs. 1.38 +/- 0.38, P = 0.034) were lower than in patients without amiodarone (n = 29). In 19 additional patients with persistent AF, oral dofetilide treatment decreased mean fibrillatory rate from 377 +/- 57 to 294 +/- 50 fpm (P < 0.001) and exponential decay from 1.24 +/- 0.43 to 0.85 +/- 0.22 (P = 0.002). CONCLUSIONS: Fibrillatory waves of surface ECG lead V1 closely reflect right atrial, and, to a lesser degree, left atrial activity. Time-frequency analysis allows noninvasive monitoring of antiarrhythmic drug effects on fibrillatory rate and waveform.


Assuntos
Fibrilação Atrial/fisiopatologia , Eletrocardiografia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/terapia , Cateterismo Cardíaco , Ablação por Cateter , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA