Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Lancet ; 403(10436): 1543-1553, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38604209

RESUMO

BACKGROUND: The coronary sinus reducer (CSR) is proposed to reduce angina in patients with stable coronary artery disease by improving myocardial perfusion. We aimed to measure its efficacy, compared with placebo, on myocardial ischaemia reduction and symptom improvement. METHODS: ORBITA-COSMIC was a double-blind, randomised, placebo-controlled trial conducted at six UK hospitals. Patients aged 18 years or older with angina, stable coronary artery disease, ischaemia, and no further options for treatment were eligible. All patients completed a quantitative adenosine-stress perfusion cardiac magnetic resonance scan, symptom and quality-of-life questionnaires, and a treadmill exercise test before entering a 2-week symptom assessment phase, in which patients reported their angina symptoms using a smartphone application (ORBITA-app). Patients were randomly assigned (1:1) to receive either CSR or placebo. Both participants and investigators were masked to study assignment. After the CSR implantation or placebo procedure, patients entered a 6-month blinded follow-up phase in which they reported their daily symptoms in the ORBITA-app. At 6 months, all assessments were repeated. The primary outcome was myocardial blood flow in segments designated ischaemic at enrolment during the adenosine-stress perfusion cardiac magnetic resonance scan. The primary symptom outcome was the number of daily angina episodes. Analysis was done by intention-to-treat and followed Bayesian methodology. The study is registered with ClinicalTrials.gov, NCT04892537, and completed. FINDINGS: Between May 26, 2021, and June 28, 2023, 61 patients were enrolled, of whom 51 (44 [86%] male; seven [14%] female) were randomly assigned to either the CSR group (n=25) or the placebo group (n=26). Of these, 50 patients were included in the intention-to-treat analysis (24 in the CSR group and 26 in the placebo group). 454 (57%) of 800 imaged cardiac segments were ischaemic at enrolment, with a median stress myocardial blood flow of 1·08 mL/min per g (IQR 0·77-1·41). Myocardial blood flow in ischaemic segments did not improve with CSR compared with placebo (difference 0·06 mL/min per g [95% CrI -0·09 to 0·20]; Pr(Benefit)=78·8%). The number of daily angina episodes was reduced with CSR compared with placebo (OR 1·40 [95% CrI 1·08 to 1·83]; Pr(Benefit)=99·4%). There were two CSR embolisation events in the CSR group, and no acute coronary syndrome events or deaths in either group. INTERPRETATION: ORBITA-COSMIC found no evidence that the CSR improved transmural myocardial perfusion, but the CSR did improve angina compared with placebo. These findings provide evidence for the use of CSR as a further antianginal option for patients with stable coronary artery disease. FUNDING: Medical Research Council, Imperial College Healthcare Charity, National Institute for Health and Care Research Imperial Biomedical Research Centre, St Mary's Coronary Flow Trust, British Heart Foundation.


Assuntos
Angina Estável , Doença da Artéria Coronariana , Seio Coronário , Intervenção Coronária Percutânea , Humanos , Masculino , Feminino , Doença da Artéria Coronariana/terapia , Angina Estável/tratamento farmacológico , Seio Coronário/diagnóstico por imagem , Teorema de Bayes , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Método Duplo-Cego , Isquemia , Adenosina
2.
Alzheimers Dement ; 20(6): 4290-4314, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38696263

RESUMO

Two of every three persons living with dementia reside in low- and middle-income countries (LMICs). The projected increase in global dementia rates is expected to affect LMICs disproportionately. However, the majority of global dementia care costs occur in high-income countries (HICs), with dementia research predominantly focusing on HICs. This imbalance necessitates LMIC-focused research to ensure that characterization of dementia accurately reflects the involvement and specificities of diverse populations. Development of effective preventive, diagnostic, and therapeutic approaches for dementia in LMICs requires targeted, personalized, and harmonized efforts. Our article represents timely discussions at the 2022 Symposium on Dementia and Brain Aging in LMICs that identified the foremost opportunities to advance dementia research, differential diagnosis, use of neuropsychometric tools, awareness, and treatment options. We highlight key topics discussed at the meeting and provide future recommendations to foster a more equitable landscape for dementia prevention, diagnosis, care, policy, and management in LMICs. HIGHLIGHTS: Two-thirds of persons with dementia live in LMICs, yet research and costs are skewed toward HICs. LMICs expect dementia prevalence to more than double, accompanied by socioeconomic disparities. The 2022 Symposium on Dementia in LMICs addressed advances in research, diagnosis, prevention, and policy. The Nairobi Declaration urges global action to enhance dementia outcomes in LMICs.


Assuntos
Envelhecimento , Demência , Países em Desenvolvimento , Humanos , Demência/diagnóstico , Demência/terapia , Demência/epidemiologia , Encéfalo , Congressos como Assunto , Pesquisa Biomédica
3.
Am Heart J ; 249: 45-56, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35305955

RESUMO

BACKGROUND: Diabetes mellitus (DM) is an important predictor of neointimal hyperplasia (NIH) and adverse clinical outcomes after percutaneous coronary intervention (PCI). LABR-312, a novel intravenous formulation of liposomal alendronate, has been shown in animal models to decrease NIH at vascular injury sites and around stent struts. The aim of the Biorest Liposomal Alendronate Administration for Diabetic Patients Undergoing Drug-Eluting Stent Percutaneous Coronary Intervention trial was to assess the safety, effectiveness, and dose response of LABR-312 administered intravenously at the time of PCI withDES in reducing NIH as measured by optical coherence tomography postprocedure in patients with DM. METHODS: Patients with DM were randomized to a bolus infusion of LABR-312 vs placebo at the time of PCI. Dose escalation of LABR-312 in the study arm was given: 0.01 mg, 0.03 mg, and 0.08 mg. The primary endpoint was the in-stent %NIH volume at 9 months as measured by optical coherence tomography. RESULTS: From September 2016 to December 2017, 271 patients with DM undergoing PCI were enrolled; 136 patients were randomized to LABR-312 infusion and 135 patients were randomized to placebo. At 9-month follow-up, no difference was seen in the primary endpoint of %NIH between LABR-312 and placebo (13.3% ± 9.2 vs 14.6% ± 8.5, P = .35). No differences were present with the varying LABR-312 doses. Clinical outcomes at 9 months were similar between groups. CONCLUSIONS: Among patients with DM undergoing PCI with drug-eluting stents, a bolus of LABR-312 injected systematically at the time of intervention did not result in a lower rate in-stent %NIH volume at 9-month follow-up.


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea , Alendronato , Angiografia Coronária/métodos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Humanos , Neointima/etiologia , Intervenção Coronária Percutânea/métodos , Tomografia de Coerência Óptica , Resultado do Tratamento
4.
NMR Biomed ; 35(7): e4692, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35040195

RESUMO

Cardiac motion results in image artefacts and quantification errors in many cardiovascular magnetic resonance (CMR) techniques, including microstructural assessment using diffusion tensor cardiovascular magnetic resonance (DT-CMR). Here, we develop a CMR-compatible isolated perfused porcine heart model that allows comparison of data obtained in beating and arrested states. Ten porcine hearts (8/10 for protocol optimisation) were harvested using a donor heart retrieval protocol and transported to the remote CMR facility. Langendorff perfusion in a 3D-printed chamber and perfusion circuit re-established contraction. Hearts were imaged using cine, parametric mapping and STEAM DT-CMR at cardiac phases with the minimum and maximum wall thickness. High potassium and lithium perfusates were then used to arrest the heart in a slack and contracted state, respectively. Imaging was repeated in both arrested states. After imaging, tissue was removed for subsequent histology in a location matched to the DT-CMR data using fiducial markers. Regular sustained contraction was successfully established in six out of 10 hearts, including the final five hearts. Imaging was performed in four hearts and one underwent the full protocol, including colocalised histology. The image quality was good and there was good agreement between DT-CMR data in equivalent beating and arrested states. Despite the use of autologous blood and dextran within the perfusate, T2 mapping results, DT-CMR measures and an increase in mass were consistent with development of myocardial oedema, resulting in failure to achieve a true diastolic-like state. A contiguous stack of 313 5-µm histological sections at and a 100-µm thick section showing cell morphology on 3D fluorescent confocal microscopy colocalised to DT-CMR data were obtained. A CMR-compatible isolated perfused beating heart setup for large animal hearts allows direct comparisons of beating and arrested heart data with subsequent colocalised histology, without the need for onsite preclinical facilities.


Assuntos
Transplante de Coração , Animais , Coração/diagnóstico por imagem , Humanos , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Miocárdio/patologia , Suínos , Doadores de Tecidos
5.
J Magn Reson Imaging ; 56(6): 1691-1704, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35460138

RESUMO

BACKGROUND: In vivo cardiac diffusion tensor imaging (cDTI) characterizes myocardial microstructure. Despite its potential clinical impact, considerable technical challenges exist due to the inherent low signal-to-noise ratio. PURPOSE: To reduce scan time toward one breath-hold by reconstructing diffusion tensors for in vivo cDTI with a fitting-free deep learning approach. STUDY TYPE: Retrospective. POPULATION: A total of 197 healthy controls, 547 cardiac patients. FIELD STRENGTH/SEQUENCE: A 3 T, diffusion-weighted stimulated echo acquisition mode single-shot echo-planar imaging sequence. ASSESSMENT: A U-Net was trained to reconstruct the diffusion tensor elements of the reference results from reduced datasets that could be acquired in 5, 3 or 1 breath-hold(s) (BH) per slice. Fractional anisotropy (FA), mean diffusivity (MD), helix angle (HA), and sheetlet angle (E2A) were calculated and compared to the same measures when using a conventional linear-least-square (LLS) tensor fit with the same reduced datasets. A conventional LLS tensor fit with all available data (12 ± 2.0 [mean ± sd] breath-holds) was used as the reference baseline. STATISTICAL TESTS: Wilcoxon signed rank/rank sum and Kruskal-Wallis tests. Statistical significance threshold was set at P = 0.05. Intersubject measures are quoted as median [interquartile range]. RESULTS: For global mean or median results, both the LLS and U-Net methods with reduced datasets present a bias for some of the results. For both LLS and U-Net, there is a small but significant difference from the reference results except for LLS: MD 5BH (P = 0.38) and MD 3BH (P = 0.09). When considering direct pixel-wise errors the U-Net model outperformed significantly the LLS tensor fit for reduced datasets that can be acquired in three or just one breath-hold for all parameters. DATA CONCLUSION: Diffusion tensor prediction with a trained U-Net is a promising approach to minimize the number of breath-holds needed in clinical cDTI studies. EVIDENCE LEVEL: 4 TECHNICAL EFFICACY: Stage 1.


Assuntos
Imagem de Tensor de Difusão , Coração , Humanos , Imagem de Tensor de Difusão/métodos , Estudos Retrospectivos , Coração/diagnóstico por imagem , Suspensão da Respiração , Anisotropia
6.
Eur Heart J ; 41(31): 2997-3004, 2020 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-32402086

RESUMO

Despite advanced understanding of the biology of atherosclerosis, coronary heart disease remains the leading cause of death worldwide. Progress has been challenging as half of the individuals who suffer sudden cardiac death do not experience premonitory symptoms. Furthermore, it is well-recognized that also a plaque that does not cause a haemodynamically significant stenosis can trigger a sudden cardiac event, yet the majority of ruptured or eroded plaques remain clinically silent. In the past 30 years since the term 'vulnerable plaque' was introduced, there have been major advances in the understanding of plaque pathogenesis and pathophysiology, shifting from pursuing features of 'vulnerability' of a specific lesion to the more comprehensive goal of identifying patient 'cardiovascular vulnerability'. It has been also recognized that aside a thin-capped, lipid-rich plaque associated with plaque rupture, acute coronary syndromes (ACS) are also caused by plaque erosion underlying between 25% and 60% of ACS nowadays, by calcified nodule or by functional coronary alterations. While there have been advances in preventive strategies and in pharmacotherapy, with improved agents to reduce cholesterol, thrombosis, and inflammation, events continue to occur in patients receiving optimal medical treatment. Although at present the positive predictive value of imaging precursors of the culprit plaques remains too low for clinical relevance, improving coronary plaque imaging may be instrumental in guiding pharmacotherapy intensity and could facilitate optimal allocation of novel, more aggressive, and costly treatment strategies. Recent technical and diagnostic advances justify continuation of interdisciplinary research efforts to improve cardiovascular prognosis by both systemic and 'local' diagnostics and therapies. The present state-of-the-art document aims to present and critically appraise the latest evidence, developments, and future perspectives in detection, prevention, and treatment of 'high-risk' plaques occurring in 'vulnerable' patients.


Assuntos
Síndrome Coronariana Aguda , Aterosclerose , Doença da Artéria Coronariana , Doença das Coronárias , Placa Aterosclerótica , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Humanos , Placa Aterosclerótica/diagnóstico por imagem
7.
Cardiology ; 145(3): 126-129, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32007999

RESUMO

A 38-year-old female with anomalous left coronary artery from the pulmonary artery presented with refractory angina (Canadian Cardiovascular Society [CCS] class 4). Having failed two previous internal mammary artery grafts to the left anterior descending artery and with no percutaneous revascularization options, she underwent coronary sinus reducer implantation, which improved her symptoms (CCS 0), quality of life, and corresponded to an improvement in ischemia on myocardial perfusion scanning. This case report describes an unusual case of refractory angina in the context of congenital heart disease, illustrates the benefit of this novel hourglass-shaped stent in improving ischemia, quality of life, depression and anxiety, and highlights the importance of managing these patients in multidisciplinary teams.


Assuntos
Angina Pectoris/cirurgia , Artéria Coronária Esquerda Anormal/cirurgia , Seio Coronário/cirurgia , Procedimentos Cirúrgicos Vasculares/instrumentação , Adulto , Angina Pectoris/diagnóstico por imagem , Angina Pectoris/fisiopatologia , Artéria Coronária Esquerda Anormal/diagnóstico por imagem , Artéria Coronária Esquerda Anormal/fisiopatologia , Angiografia Coronária , Seio Coronário/diagnóstico por imagem , Seio Coronário/fisiopatologia , Feminino , Humanos , Qualidade de Vida , Stents , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/efeitos adversos
9.
N Engl J Med ; 372(6): 519-27, 2015 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-25651246

RESUMO

BACKGROUND: Many patients with coronary artery disease who are not candidates for revascularization have refractory angina despite standard medical therapy. The balloon-expandable, stainless steel, hourglass-shaped, coronary-sinus reducing device creates a focal narrowing and increases pressure in the coronary sinus, thus redistributing blood into ischemic myocardium. METHODS: We randomly assigned 104 patients with Canadian Cardiovascular Society (CCS) class III or IV angina (on a scale from I to IV, with higher classes indicating greater limitations on physical activity owing to angina) and myocardial ischemia, who were not candidates for revascularization, to implantation of the device (treatment group) or to a sham procedure (control group). The primary end point was the proportion of patients with an improvement of at least two CCS angina classes at 6 months. RESULTS: A total of 35% of the patients in the treatment group (18 of 52 patients), as compared with 15% of those in the control group (8 of 52), had an improvement of at least two CCS angina classes at 6 months (P=0.02). The device was also associated with improvement of at least one CCS angina class in 71% of the patients in the treatment group (37 of 52 patients), as compared with 42% of those in the control group (22 of 52) (P=0.003). Quality of life as assessed with the use of the Seattle Angina Questionnaire was significantly improved in the treatment group, as compared with the control group (improvement on a 100-point scale, 17.6 vs. 7.6 points; P=0.03). There were no significant between-group differences in improvement in exercise time or in the mean change in the wall-motion index as assessed by means of dobutamine echocardiography. At 6 months, 1 patient in the treatment group had had a myocardial infarction; in the control group, 1 patient had died and 3 had had a myocardial infarction. CONCLUSIONS: In this small clinical trial, implantation of the coronary-sinus reducing device was associated with significant improvement in symptoms and quality of life in patients with refractory angina who were not candidates for revascularization. (Funded by Neovasc; COSIRA ClinicalTrials.gov number, NCT01205893.).


Assuntos
Angina Pectoris/terapia , Cateteres Cardíacos , Seio Coronário , Revascularização Miocárdica/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Angina Pectoris/classificação , Cateterismo Cardíaco , Angiografia Coronária , Seio Coronário/diagnóstico por imagem , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Gravidade do Paciente , Qualidade de Vida , Telas Cirúrgicas
10.
Magn Reson Med ; 79(4): 2205-2215, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28734017

RESUMO

PURPOSE: To evaluate the importance of strain-correcting stimulated echo acquisition mode echo-planar imaging cardiac diffusion tensor imaging. METHODS: Healthy pigs (n = 11) were successfully scanned with a 3D cine displacement-encoded imaging with stimulated echoes and a monopolar-stimulated echo-planar imaging diffusion tensor imaging sequence at 3 T during diastasis, peak systole, and strain sweet spots in a midventricular short-axis slice. The same diffusion tensor imaging sequence was repeated ex vivo after arresting the hearts in either a relaxed (KCl-induced) or contracted (BaCl2 -induced) state. The displacement-encoded imaging with stimulated echoes data were used to strain-correct the in vivo cardiac diffusion tensor imaging in diastole and systole. The orientation of the primary (helix angles) and secondary (E2A) diffusion eigenvectors was compared with and without strain correction and to the strain-free ex vivo data. RESULTS: Strain correction reduces systolic E2A significantly when compared without strain correction and ex vivo (median absolute E2A = 34.3° versus E2A = 57.1° (P = 0.01), E2A = 60.5° (P = 0.006), respectively). The systolic distribution of E2A without strain correction is closer to the contracted ex vivo distribution than with strain correction, root mean square deviation of 0.027 versus 0.038. CONCLUSIONS: The current strain-correction model amplifies the contribution of microscopic strain to diffusion resulting in an overcorrection of E2A. Results show that a new model that considers cellular rearrangement is required. Magn Reson Med 79:2205-2215, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Imagem de Tensor de Difusão , Coração/diagnóstico por imagem , Algoritmos , Animais , Simulação por Computador , Diástole , Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética , Respiração , Respiração Artificial , Software , Estresse Mecânico , Suínos , Sístole
12.
13.
Circulation ; 132(11): 1003-12, 2015 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-26179404

RESUMO

BACKGROUND: Although disturbed flow is thought to play a central role in the development of advanced coronary atherosclerotic plaques, no causal relationship has been established. We evaluated whether inducing disturbed flow would cause the development of advanced coronary plaques, including thin cap fibroatheroma. METHODS AND RESULTS: D374Y-PCSK9 hypercholesterolemic minipigs (n=5) were instrumented with an intracoronary shear-modifying stent (SMS). Frequency-domain optical coherence tomography was obtained at baseline, immediately poststent, 19 weeks, and 34 weeks, and used to compute shear stress metrics of disturbed flow. At 34 weeks, plaque type was assessed within serially collected histological sections and coregistered to the distribution of each shear metric. The SMS caused a flow-limiting stenosis, and blood flow exiting the SMS caused regions of increased shear stress on the outer curvature and large regions of low and multidirectional shear stress on the inner curvature of the vessel. As a result, plaque burden was ≈3-fold higher downstream of the SMS than both upstream of the SMS and in the control artery (P<0.001). Advanced plaques were also primarily observed downstream of the SMS, in locations initially exposed to both low (P<0.002) and multidirectional (P<0.002) shear stress. Thin cap fibroatheroma regions demonstrated significantly lower shear stress that persisted over the duration of the study in comparison with other plaque types (P<0.005). CONCLUSIONS: These data support a causal role for lowered and multidirectional shear stress in the initiation of advanced coronary atherosclerotic plaques. Persistently lowered shear stress appears to be the principal flow disturbance needed for the formation of thin cap fibroatheroma.


Assuntos
Aterosclerose/etiologia , Aterosclerose/fisiopatologia , Vasos Coronários/fisiopatologia , Hipercolesterolemia/complicações , Placa Aterosclerótica/etiologia , Placa Aterosclerótica/fisiopatologia , Fluxo Sanguíneo Regional/fisiologia , Animais , Animais Geneticamente Modificados , Angiografia Coronária , Circulação Coronária/fisiologia , Modelos Animais de Doenças , Hemodinâmica/fisiologia , Hipercolesterolemia/genética , Hipercolesterolemia/fisiopatologia , Pró-Proteína Convertases/genética , Resistência ao Cisalhamento/fisiologia , Stents , Estresse Mecânico , Suínos , Porco Miniatura , Fatores de Tempo , Tomografia de Coerência Óptica
14.
J Cardiovasc Magn Reson ; 18(1): 93, 2016 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-27964736

RESUMO

BACKGROUND: Wave intensity analysis (WIA) of the coronary arteries allows description of the predominant mechanisms influencing coronary flow over the cardiac cycle. The data are traditionally derived from pressure and velocity changes measured invasively in the coronary artery. Cardiovascular magnetic resonance (CMR) allows measurement of coronary velocities using phase velocity mapping and derivation of central aortic pressure from aortic distension. We assessed the feasibility of WIA of the coronary arteries using CMR and compared this to invasive data. METHODS: CMR scans were undertaken in a serial cohort of patients who had undergone invasive WIA. Velocity maps were acquired in the proximal left anterior descending and proximal right coronary artery using a retrospectively-gated breath-hold spiral phase velocity mapping sequence with high temporal resolution (19 ms). A breath-hold segmented gradient echo sequence was used to acquire through-plane cross sectional area changes in the proximal ascending aorta which were used as a surrogate of an aortic pressure waveform after calibration with brachial blood pressure measured with a sphygmomanometer. CMR-derived aortic pressures and CMR-measured velocities were used to derive wave intensity. The CMR-derived wave intensities were compared to invasive data in 12 coronary arteries (8 left, 4 right). Waves were presented as absolute values and as a % of total wave intensity. Intra-study reproducibility of invasive and non-invasive WIA was assessed using Bland-Altman analysis and the intraclass correlation coefficient (ICC). RESULTS: The combination of the CMR-derived pressure and velocity data produced the expected pattern of forward and backward compression and expansion waves. The intra-study reproducibility of the CMR derived wave intensities as a % of the total wave intensity (mean ± standard deviation of differences) was 0.0 ± 6.8%, ICC = 0.91. Intra-study reproducibility for the corresponding invasive data was 0.0 ± 4.4%, ICC = 0.96. The invasive and CMR studies showed reasonable correlation (r = 0.73) with a mean difference of 0.0 ± 11.5%. CONCLUSION: This proof of concept study demonstrated that CMR may be used to perform coronary WIA non-invasively with reasonable reproducibility compared to invasive WIA. The technique potentially allows WIA to be performed in a wider range of patients and pathologies than those who can be studied invasively.


Assuntos
Circulação Coronária , Vasos Coronários/diagnóstico por imagem , Cardiopatias/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Adulto , Aorta/diagnóstico por imagem , Aorta/fisiopatologia , Pressão Arterial , Velocidade do Fluxo Sanguíneo , Suspensão da Respiração , Calibragem , Vasos Coronários/fisiopatologia , Inglaterra , Estudos de Viabilidade , Feminino , Cardiopatias/fisiopatologia , Humanos , Imagem Cinética por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
15.
Cardiovasc Drugs Ther ; 30(4): 407-417, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27475447

RESUMO

Stable angina pectoris affects 2-4 % of the population in Western countries and entails an annual risk of death and nonfatal myocardial infarction of 1-2 % and 3 %, respectively. Heart rate (HR) is linearly related to myocardial oxygen consumption and coronary blood flow, both at rest and during stress. HR reduction is a key target for the prevention of ischemia/angina and is an important mechanism of action of drugs which are recommended as first line therapy for the treatment of angina in clinical guidelines. However, many patients are often unable to tolerate the doses of beta blocker or non-dihydropyridine calcium antagonists required to achieve the desired symptom control. The selective pacemaker current inhibitor ivabradine was developed as a drug for the management of patients with angina pectoris, through its ability to reduce HR specifically. The available data suggest that ivabradine is a well-tolerated and effective anti-anginal agent and it is recommended as a second-line agent for relief of angina in guidelines. However, recent clinical trials of ivabradine have failed to show prognostic benefit and have raised potential concerns about safety. This article will review the available evidence base for the current role of ivabradine in the management of patients with symptomatic angina pectoris in the context of stable coronary artery disease.


Assuntos
Angina Pectoris/tratamento farmacológico , Benzazepinas/uso terapêutico , Fármacos Cardiovasculares/uso terapêutico , Angina Pectoris/fisiopatologia , Benzazepinas/efeitos adversos , Benzazepinas/farmacocinética , Benzazepinas/farmacologia , Fármacos Cardiovasculares/efeitos adversos , Fármacos Cardiovasculares/farmacocinética , Fármacos Cardiovasculares/farmacologia , Interações Medicamentosas , Quimioterapia Combinada , Frequência Cardíaca/efeitos dos fármacos , Humanos , Ivabradina
16.
Arterioscler Thromb Vasc Biol ; 34(10): 2224-31, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25060797

RESUMO

In this review, we summarized the effect of mechanical factors (shear and wall stress) on thin-cap fibroatheroma formation and rupture. To make this review understandable for a biology-oriented audience, we start with detailed definitions of relevant mechanical metrics. We then describe how biomechanics has supported histopathologic efforts to understand the basis of plaque rupture. In addition to plaque rupture, biomechanics also contributes toward the progression of thin-cap fibroatheroma through a multitude of reported mechanobiological mechanisms. We thus propose a new mechanism whereby both shear stress and wall stress interact to create thin-cap fibroatheromas. Specifically, when regions of certain blood flow and wall mechanical stimuli coincide, they synergistically create inflammation within the cellular environment that can lead to thin-cap fibroatheroma rupture. A consequence of this postulate is that local shear stress is not sufficient to cause rupture, but it must coincide with regions of local tissue stiffening and stress concentrations that can occur during plaque progression. Because such changes to the wall mechanics occur over a micrometer scale, high spatial resolution imaging techniques will be necessary to evaluate this hypothesis and ultimately predict plaque rupture in a clinical environment.


Assuntos
Artérias/patologia , Aterosclerose/patologia , Mecanotransdução Celular , Placa Aterosclerótica , Animais , Artérias/metabolismo , Artérias/fisiopatologia , Aterosclerose/complicações , Aterosclerose/metabolismo , Aterosclerose/fisiopatologia , Fenômenos Biomecânicos , Progressão da Doença , Fibrose , Humanos , Fluxo Sanguíneo Regional , Fatores de Risco , Ruptura Espontânea , Estresse Mecânico
17.
J Cardiovasc Magn Reson ; 17: 85, 2015 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-26428627

RESUMO

BACKGROUND: Temporal patterns of coronary blood flow velocity can provide important information on disease state and are currently assessed invasively using a Doppler guidewire. A non-invasive alternative would be beneficial as it would allow study of a wider patient population and serial scanning. METHODS: A retrospectively-gated breath-hold spiral phase velocity mapping sequence (TR 19 ms) was developed at 3 Tesla. Velocity maps were acquired in 8 proximal right and 15 proximal left coronary arteries of 18 subjects who had previously had a Doppler guidewire study at the time of coronary angiography. Cardiovascular magnetic resonance (CMR) velocity-time curves were processed semi-automatically and compared with corresponding invasive Doppler data. RESULTS: When corrected for differences in heart rate between the two studies, CMR mean velocity through the cardiac cycle, peak systolic velocity (PSV) and peak diastolic velocity (PDV) were approximately 40 % of the peak Doppler values with a moderate - good linear relationship between the two techniques (R(2): 0.57, 0.64 and 0.79 respectively). CMR values of PDV/PSV showed a strong linear relationship with Doppler values with a slope close to unity (0.89 and 0.90 for right and left arteries respectively). In individual vessels, plots of CMR velocities at all cardiac phases against corresponding Doppler velocities showed a consistent linear relationship between the two with high R(2) values (mean +/-SD: 0.79 +/-.13). CONCLUSIONS: High temporal resolution breath-hold spiral phase velocity mapping underestimates absolute values of coronary flow velocity but allows accurate assessment of the temporal patterns of blood flow.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Circulação Coronária , Vasos Coronários/fisiopatologia , Ecocardiografia Doppler/métodos , Imageamento por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Adulto , Idoso , Automação , Velocidade do Fluxo Sanguíneo , Suspensão da Respiração , Cateteres Cardíacos , Técnicas de Imagem de Sincronização Cardíaca , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Ecocardiografia Doppler/instrumentação , Eletrocardiografia , Feminino , Frequência Cardíaca , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/instrumentação , Valor Preditivo dos Testes , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Fatores de Tempo
18.
Cytotherapy ; 16(12): 1720-32, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25239491

RESUMO

BACKGROUND AIMS: CD133+ cells confer angiogenic potential and may be beneficial for the treatment of critical limb ischemia (CLI). However, patient selection, blinding methods and end points for clinical trials are challenging. We hypothesized that bilateral intramuscular administration of cytokine-mobilized CD133+ cells in ambulatory patients with refractory CLI would be feasible and safe. METHODS: In this double-blind, randomized sham-controlled trial, subjects received subcutaneous injections of granulocyte colony-stimulating factor (10 µg/kg per day) for 5 days, followed by leukapheresis, and intramuscular administration of 50-400 million sorted CD133+ cells delivered into both legs. Control subjects received normal saline injections, sham leukapheresis and intramuscular injection of placebo buffered solution. Subjects were followed for 1 year. An aliquot of CD133+ cells was collected from each subject to test for genes associated with cell senescence. RESULTS: Seventy subjects were screened, of whom 10 were eligible. Subject enrollment was suspended because of a high rate of mobilization failure in subjects randomly assigned to treatment. Of 10 subjects enrolled (7 randomly assigned to treatment, 3 randomly assigned to control), there were no differences in serious adverse events at 12 months, and blinding was preserved. There were non-significant trends toward improved amputation-free survival, 6-minute walk distance, walking impairment questionnaire and quality of life in subjects randomly assigned to treatment. Successful CD133+ mobilizers expressed fewer senescence-associated genes compared with poor mobilizers. CONCLUSIONS: Bilateral administration of autologous CD133+ cells in ambulatory CLI subjects was safe, and blinding was preserved. However, poor mobilization efficiency combined with high CD133+ senescence suggests futility in this approach.


Assuntos
Antígenos CD , Extremidades/irrigação sanguínea , Glicoproteínas , Isquemia/terapia , Peptídeos , Doença Arterial Periférica/terapia , Transplante de Células-Tronco , Células-Tronco , Antígeno AC133 , Idoso , Autoenxertos , Método Duplo-Cego , Extremidades/patologia , Feminino , Seguimentos , Humanos , Isquemia/patologia , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/patologia , Recuperação de Função Fisiológica
19.
J Cardiovasc Magn Reson ; 16: 87, 2014 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-25388867

RESUMO

BACKGROUND: Cardiac diffusion tensor imaging (cDTI) measures the magnitudes and directions of intramyocardial water diffusion. Assuming the cross-myocyte components to be constrained by the laminar microstructures of myocardium, we hypothesized that cDTI at two cardiac phases might identify any abnormalities of laminar orientation and mobility in hypertrophic cardiomyopathy (HCM). METHODS: We performed cDTI in vivo at 3 Tesla at end-systole and late diastole in 11 healthy controls and 11 patients with HCM, as well as late gadolinium enhancement (LGE) for detection of regional fibrosis. RESULTS: Voxel-wise analysis of diffusion tensors relative to left ventricular coordinates showed expected transmural changes of myocardial helix-angle, with no significant differences between phases or between HCM and control groups. In controls, the angle of the second eigenvector of diffusion (E2A) relative to the local wall tangent plane was larger in systole than diastole, in accord with previously reported changes of laminar orientation. HCM hearts showed higher than normal global E2A in systole (63.9° vs 56.4° controls, p=0.026) and markedly raised E2A in diastole (46.8° vs 24.0° controls, p<0.001). In hypertrophic regions, E2A retained a high, systole-like angulation even in diastole, independent of LGE, while regions of normal wall thickness did not (LGE present 57.8°, p=0.0028, LGE absent 54.8°, p=0.0022 vs normal thickness 38.1°). CONCLUSIONS: In healthy controls, the angles of cross-myocyte components of diffusion were consistent with previously reported transmural orientations of laminar microstructures and their changes with contraction. In HCM, especially in hypertrophic regions, they were consistent with hypercontraction in systole and failure of relaxation in diastole. Further investigation of this finding is required as previously postulated effects of strain might be a confounding factor.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico , Imagem de Difusão por Ressonância Magnética , Imagem de Tensor de Difusão , Imagem Cinética por Ressonância Magnética , Contração Miocárdica , Miocárdio/patologia , Função Ventricular Esquerda , Idoso , Cardiomiopatia Hipertrófica/patologia , Cardiomiopatia Hipertrófica/fisiopatologia , Estudos de Casos e Controles , Feminino , Fibrose , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
20.
Eur Heart J Case Rep ; 8(5): ytae228, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38745729

RESUMO

Background: Granulomatosis with Polyangiitis (GPA) is a rare multi-system autoimmune disorder that may present with cardiac manifestations that are often under-recognized. In this report, we discuss a usual case of a patient who presented as a cardiac emergency with recurrent ST elevation and discuss the approach and management. Case summary: A 44-year-old man presented with two episodes of chest pain associated with ST-segment elevation on 12-lead ECG. Under investigation over the past several weeks for fatigue, nasal congestion, and red eyes, his first presentation was associated with widespread ST-segment elevation and an echogenic myocardium suggestive of myocarditis that was confirmed on cardiac MRI. A week later, the development of chest pain, antero-lateral ST elevation, and regional wall motion abnormalities suggested an acute coronary syndrome and he proceeded to primary percutaneous intervention that treated a lesion in the distal left anterior descending artery secondary to coronary arteritis. Diagnosed with GPA, he was started on immunosuppression and has had a resolution of his cardiac involvement at follow-up. Discussion: This case report describes an unusual case of myocarditis and coronary arteritis presenting acutely in the same patient and emphasizes the importance of considering systemic autoimmune conditions when encountering primarily cardiac presentations. Early recognition and diagnosis of cardiac involvement will improve the long-term outcomes in these patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA