Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
AIDS Res Ther ; 21(1): 13, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38439093

RESUMO

BACKGROUND: Cardiovascular disease (CVD) remains a leading cause of death in people living with HIV. Myocardial fibrosis is well-described in HIV infection acquired in adulthood. We evaluate the burden of fibrosis by cardiac magnetic resonance in people with perinatal HIV infection. METHODS: Individuals with perinatally acquired HIV (pnHIV) diagnosed before 10 years-old and on antiretroviral treatment for ≥ 6 months were matched with uninfected controls. Patients with significant cardiometabolic co-morbidities and pregnancy were excluded. Diffuse fibrosis was assessed by cardiac magnetic resonance (CMR) with native T1 mapping for calculation of extracellular volume fraction (ECV). Viability was assessed with late gadolinium enhancement. The normality of fibrosis was assessed using the Komogrov-Smirnov test. Fibrosis between the groups was analyzed using a Mann-Whitney U test, as the data was not normally distributed. Statistical significance was defined as a p-valve < 0.05. RESULTS: Fourteen adults with pnHIV group and 26 controls (71% female and 86% Black race) were assessed. The average (± standard deviation) age in the study group was 29 (± 4.3) years-old. All pnHIV had been on ART for decades. Demographic data, CMR functional/volumetric data, and pre-contrast T1 mapping values were similar between groups. Diastolic function was normal in 50% of pnHIV patients and indeterminate in most of the remainder (42%). There was no statistically significant difference in ECV between groups; p = 0.24. CONCLUSION: Perinatally-acquired HIV was not associated with diffuse myocardial fibrosis. Larger prospective studies with serial examinations are needed to determine whether pnHIV patients develop abnormal structure or function more often than unaffected controls.


Assuntos
Infecções por HIV , Adulto , Gravidez , Humanos , Feminino , Adulto Jovem , Criança , Masculino , Infecções por HIV/complicações , Infecções por HIV/tratamento farmacológico , Meios de Contraste , Estudos Prospectivos , Gadolínio , Fibrose
2.
Radiology ; 305(2): 329-338, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35880980

RESUMO

Background The relationship between papillary muscle infarction (papMI) and the culprit coronary lesion has not been fully investigated. Delayed enhancement cardiac MRI may detect papMI, yet its accuracy is unknown. Flow-independent dark-blood delayed enhancement (FIDDLE) cardiac MRI has been shown to improve the detection of myocardial infarction adjacent to blood pool. Purpose To assess the diagnostic performance of delayed enhancement and FIDDLE cardiac MRI for the detection of papMI, and to investigate the prevalence of papMI and its relationship to the location of the culprit coronary lesion. Materials and Methods A prospective canine study was used to determine the accuracy of conventional delayed enhancement imaging and FIDDLE imaging for detection of papMI, with pathology-based findings as the reference standard. Participants with first-time myocardial infarction with a clear culprit lesion at coronary angiography were prospectively enrolled at a single hospital from 2015 to 2018 and compared against control participants with low Framingham risk scores. In canines, diagnostic accuracy was calculated for delayed enhancement and FIDDLE imaging. Results In canines (n = 27), FIDDLE imaging was more sensitive (100% [23 of 23] vs 57% [13 of 23], P < .001) and accurate (100% [54 of 54] vs 80% [43 of 54], P = .01) than delayed enhancement imaging for detection of papMI. In 43 participants with myocardial infarction (mean age, 56 years ± 16 [SD]; 28 men), the infarct-related artery was the left anterior descending coronary artery (LAD), left circumflex coronary artery (LCX), and right coronary artery in 47% (20 of 43), 26% (11 of 43), and 28% (12 of 43), respectively. The prevalence of anterior papMI was lower than posterior papMI (37% [16 of 43 participants] vs 44% [19 of 43 participants]) despite more LAD culprit lesions. Culprits leading to papMI were restricted to a smaller "at-risk" portion of the coronary tree for anterior papMI (subtended first diagonal branch of the LAD or first marginal branch of the LCX) compared with posterior (subtended posterior descending artery or third obtuse marginal branch of the LCX). Culprits within these at-risk portions were predictive of papMI at a similar rate (anterior, 83% [15 of 18 participants] vs posterior, 86% [18 of 21 participants]). Conclusion Flow-independent dark-blood delayed enhancement cardiac MRI, unlike conventional delayed enhancement cardiac MRI, was highly accurate in the detection of papillary muscle infarction (papMI). Anterior papMI was less prevalent than posterior papMI, most likely due to culprit lesions being restricted to a smaller portion of the coronary tree rather than because of redundant, dual vascular supply. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Kawel-Boehm and Bremerich in this issue.


Assuntos
Infarto do Miocárdio , Músculos Papilares , Masculino , Humanos , Cães , Animais , Pessoa de Meia-Idade , Músculos Papilares/diagnóstico por imagem , Músculos Papilares/patologia , Estudos Prospectivos , Infarto do Miocárdio/diagnóstico por imagem , Vasos Coronários/patologia , Angiografia Coronária/efeitos adversos , Infarto , Imageamento por Ressonância Magnética/efeitos adversos
3.
NMR Biomed ; 35(10): e4777, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35633068

RESUMO

Myocardial lipomatous metaplasia, which can serve as substrate for ventricular arrhythmias, is usually composed of regions in which there is an admixture of fat and nonfat tissue. Although dedicated sequences for the detection of fat are available, it would be time-consuming and burdensome to routinely use these techniques to image the entire heart of all patients as part of a typical cardiac MRI exam. Conventional steady-state free-precession (SSFP) cine imaging is insensitive to detecting myocardial regions with partial fatty infiltration. We developed an optimization process for SSFP imaging to set fat signal consistently "out-of-phase" with water throughout the heart, so that intramyocardial regions with partial volume fat would be detected as paradoxically dark regions. The optimized SSFP sequence was evaluated using a fat phantom, through simulations, and in 50 consecutive patients undergoing clinical cardiac MRI. Findings were validated using standard Dixon gradient-recalled-echo (GRE) imaging as the reference. Phantom studies of test tubes with diverse fat concentrations demonstrated good agreement between measured signal intensity and simulated values calculated using Bloch equations. In patients, a line of signal cancellation at the interface between myocardium and epicardial fat was noted in all cases, confirming that SSFP images were consistently out-of-phase throughout the entire heart. Intramyocardial dark regions identified on out-of-phase SSFP images were entirely dark throughout in 33 patients (66%) and displayed an India-ink pattern in 17 (34%). In all cases, dark intramyocardial regions were also seen in the same locations on out-of-phase GRE and were absent on in-phase GRE, confirming that these regions represent areas with partial fat. In conclusion, if appropriately optimized, SSFP cine imaging allows for consistent detection of myocardial fatty metaplasia in patients undergoing routine clinical cardiac MRI without the need for additional image acquisitions using dedicated fat-specific sequences.


Assuntos
Imageamento por Ressonância Magnética , Miocárdio , Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Metaplasia , Imagens de Fantasmas
4.
J Cardiovasc Magn Reson ; 24(1): 68, 2022 12 05.
Artigo em Inglês | MEDLINE | ID: mdl-36464719

RESUMO

The Society for Cardiovascular Magnetic Resonance (SCMR) recommendations for training and competency of cardiovascular magnetic resonance (CMR) technologists document will define the knowledge, experiences and skills required for a technologist to be competent in CMR imaging. By providing a framework for CMR training and competency the overarching goal is to promote the performance of high-quality CMR and to foster the increased adoption of CMR into clinical care.


Assuntos
Sistema Cardiovascular , Imageamento por Ressonância Magnética , Humanos , Valor Preditivo dos Testes , Espectroscopia de Ressonância Magnética
5.
J Cardiovasc Magn Reson ; 24(1): 42, 2022 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-35787291

RESUMO

The Society for Cardiovascular Magnetic Resonance (SCMR) is an international society focused on the research, education, and clinical application of cardiovascular magnetic resonance (CMR). "Cases of SCMR" is a case series hosted on the SCMR website ( https://www.scmr.org ) that demonstrates the utility and importance of CMR in the clinical diagnosis and management of cardiovascular disease. The COVID-19 Case Collection highlights the impact of coronavirus disease 2019 (COVID-19) on the heart as demonstrated on CMR. Each case in series consists of the clinical presentation and the role of CMR in diagnosis and guiding clinical management. The cases are all instructive and helpful in the approach to patient management. We present a digital archive of the 2021 Cases of SCMR and the 2020 and 2021 COVID-19 Case Collection series of nine cases as a means of further enhancing the education of those interested in CMR and as a means of more readily identifying these cases using a PubMed or similar literature search engine.


Assuntos
COVID-19 , Sistema Cardiovascular , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes
6.
NMR Biomed ; 34(10): e4580, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34251717

RESUMO

Despite clinical use of late gadolinium enhancement (LGE) for two decades, an efficient, robust fat suppression (FS) technique still does not exist for this CMR mainstay. In ischemic and non-ischemic heart disease, differentiating fibrotic tissue from infiltrating and adjacent fat is crucial. Multiple groups have independently developed an FS technique for LGE, double spectral attenuated inversion recovery (DSPAIR), but no comprehensive evaluation was performed. This study aims to fill this gap. DSPAIR uses two SPAIR pulses and one non-selective IR pulse to enable FS LGE, including compatibility with phase sensitive inversion recovery (PSIR). We implemented a magnitude (MAGN) and a PSIR variant and compared them with LGE without FS (CONTROL) and with spectral presaturation with inversion recovery (SPIR) in simulations, phantoms, and patients. Fat magnetization by SPIR, MAGN DSPAIR, and PSIR DSPAIR was simulated as a function of pulse B1 , readout (RO) pulse number, and fat TI . A phantom with fat, fibrosis, and myocardium compartments was imaged using all FS methods and modifying pulse B1 , RO pulse number, and heart rate. Signal was measured in SNR units. Fat, myocardium, and fibrosis SNR and fibrosis-to-fat CNR were obtained. Patient images were acquired with all FS techniques. Fat, myocardium, and fibrosis SNR, fibrosis-to-fat CNR, and image and FS quality were assessed. In the phantom, both DSPAIR variants provided superior FS compared with SPIR, independent of heart rate and RO pulse number. MAGN DSPAIR reduced fat signal by 99% compared with CONTROL, PSIR DSPAIR by 116%, and SPIR by 67% (25 RO pulses). In patients, both DSPAIR variants substantially reduced fat signal (MAGN DSPAIR by 87.1% ± 10.0%, PSIR DSPAIR by 130.5% ± 36.3%), but SPIR did not (35.8% ± 25.5%). FS quality was good to excellent for MAGN and PSIR DSPAIR, and moderate to poor for SPIR. DSPAIR provided highly effective FS across a wide range of parameters. PSIR DSPAIR performed best.


Assuntos
Gadolínio/química , Lipídeos/química , Imageamento por Ressonância Magnética , Displasia Arritmogênica Ventricular Direita/diagnóstico por imagem , Simulação por Computador , Humanos , Pessoa de Meia-Idade , Imagens de Fantasmas , Razão Sinal-Ruído
7.
Eur Radiol ; 31(7): 5087-5095, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33409772

RESUMO

OBJECTIVE: Cardiac motion and aortic pulsatility can affect the image quality of 3D contrast-enhanced MR angiography (CE-MRA). The addition of ECG gating improves image quality; however, no studies have directly linked image quality improvements to clinically used measures. In this study, we directly compared diameter measurements in the same patient from ECG-gated to non-gated CE-MRA to evaluate the impact of ECG gating upon measurement reproducibility. METHODS: Fifty-three patients, referred for thoracic aortic angiography, were enrolled and underwent both non-gated and ECG-gated CE-MRA. Two readers independently measured vessel diameter, image quality, and vessel sharpness at the sinus of Valsalva (SOV), sinotubular junction (STJX), ascending aorta (AAO), distal aortic arch (DLSA), and descending aorta (DAO). Measurement reliability and reproducibility were compared between methods. RESULTS: Image quality with ECG gating was rated significantly higher at the SOV (3.2 ± 0.9 vs 1.2 ± 1.0, p < 0.0001), STJX (3.4 ± 0.7 vs 1.8 ± 1.0, p < 0.0001), AAO (3.5 ± 0.6 vs 1.7 ± 1.1 p < 0.0001), DLSA (4.0 ± 0.1 vs 3.6 ± 0.7, p = 0.006), and DAO (4.0 ± 0.1 vs 3.4 ± 0.9 p < 0.0001) than for non-gated studies. Bland-Altman analyses demonstrated that inter- and intra-observer variability was significantly smaller for ECG-gated MRA at the SOV and AAO. For the non-gated images at the SOV, the 95% limits of agreement for both inter- and intra-observer variability exceeded the growth-rate cutoff for surgical repair (0.5 cm). At the DAO, variability was similar between the two techniques. CONCLUSION: ECG-gated CE-MRA resulted in improved reproducibility in aortic root and ascending aortic measurements. These data suggest that ECG-gated CE-MRA should be used for the serial assessment of the ascending thoracic aorta. KEY POINTS: • ECG-gated CE-MRA improves the reproducibility and repeatability of measurements of the ascending aorta. • With non-gated CE-MRA, pulsatile motion in the proximal aorta results in significant variability in measurement reproducibility.


Assuntos
Aorta Torácica , Angiografia por Ressonância Magnética , Aorta/diagnóstico por imagem , Meios de Contraste , Eletrocardiografia , Humanos , Reprodutibilidade dos Testes
8.
NMR Biomed ; 33(11): e4396, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32875674

RESUMO

Recently developed dark-blood techniques such as Flow-Independent Dark-blood DeLayed Enhancement (FIDDLE) allow simultaneous visualization of tissue contrast-enhancement and blood-pool suppression. Critical to FIDDLE is the magnetization preparation, which accentuates differences between myocardium and blood-pool. Here, we compared magnetization transfer (MT)-preparation and T2-preparation for use with FIDDLE. Variants of FIDDLE were developed with MT- or T2-preparation modules and tested in 35 patients (11 at 1.5 T, 24 at 3 T). Images were acquired with each FIDDLE variant in an interleaved fashion 10 minutes after gadolinium administration with otherwise identical acquisition parameters. Images were visually and quantitatively assessed for artifacts and differences in right ventricle to left ventricle (RV-to-LV) blood-pool suppression. Bright artifacts, reflecting incomplete blood-pool suppression, were frequently observed in the left atrium with T2-preparation FIDDLE at 1.5 and 3 T (82% and up to 100% of patients, respectively). MT-preparation FIDDLE resulted in fewer patients with artifacts (0% at 1.5 T, 22% at 3 T; P < .01). Left atrial blood-pool signal was significantly more homogeneous with MT-preparation than with T2-preparation at 1.5 and 3 T (P < .001 for all comparisons). Visibly different RV-to-LV blood-pool suppression was observed with T2-preparation in 36% of patients at 1.5 T and up to 94% at 3 T. In these patients, RV blood-pool signal was elevated, reducing the conspicuity of the myocardial-RV blood-pool border. Conversely, there were no visible differences in RV-to-LV blood-pool suppression with MT-preparation. Quantitative assessment of differences in blood-pool suppression and blood-pool artifacts was consistent with visual analyses. We conclude that for dark blood-blood delayed-enhancement imaging of the heart, MT-preparation results in fewer bright blood-pool artifacts and more uniform blood-pool suppression than T2-preparation.


Assuntos
Sangue/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adulto , Artefatos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído
10.
Magn Reson Med ; 78(4): 1442-1451, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-27868238

RESUMO

PURPOSE: We demonstrate an improved segmented inversion-recovery sequence that suppresses ghost artifacts arising from tissues with long T1 ( > 1.5 s). THEORY AND METHODS: Long T1 species such as pericardial fluid can create bright ghost artifacts in segmented, inversion-recovery MRI because of oscillations in longitudinal magnetization between segments. A single dummy acquisition at the beginning of the sequence can reduce oscillations; however, its effectiveness in suppressing long T1 artifacts is unknown. In this study, we systematically evaluated several test sequences, including a prototype (saturation post-pulse readout to eliminate spurious signal: SPPRESS) in simulations, phantoms, and patients. RESULTS: SPPRESS reduced artifact signal 90% ± 25% and 74% ± 28% compared with Control and Single-Dummy methods in phantoms. SPPRESS performed well at 1.5 Tesla (T) and 3T, with steady-state free precession (SSFP) and fast low-angle shot (FLASH) readout, with conventional and phase-sensitive reconstruction, and over a range of physiologic heart rates. A review of 100 consecutive clinical cardiac MRI scans revealed large fluid collections (eg, regions with long T1 ) in 14% of patients. In a prospectively enrolled cohort of 16 patients with visible long T1 fluids, SPPRESS appreciably reduced artifacts in all cases compared with Control and Single-Dummy methods. CONCLUSION: We developed and validated a new robust method, SPPRESS, for reducing artifacts due to long T1 species across a wide range of imaging and physiologic conditions. Magn Reson Med 78:1442-1451, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Artefatos , Meios de Contraste , Gadolínio , Coração/diagnóstico por imagem , Humanos , Imagens de Fantasmas
11.
Circ Res ; 117(3): 254-65, 2015 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-25972514

RESUMO

RATIONALE: After acute myocardial infarction (MI), delineating the area-at-risk (AAR) is crucial for measuring how much, if any, ischemic myocardium has been salvaged. T2-weighted MRI is promoted as an excellent method to delineate the AAR. However, the evidence supporting the validity of this method to measure the AAR is indirect, and it has never been validated with direct anatomic measurements. OBJECTIVE: To determine whether T2-weighted MRI delineates the AAR. METHODS AND RESULTS: Twenty-one canines and 24 patients with acute MI were studied. We compared bright-blood and black-blood T2-weighted MRI with images of the AAR and MI by histopathology in canines and with MI by in vivo delayed-enhancement MRI in canines and patients. Abnormal regions on MRI and pathology were compared by (a) quantitative measurement of the transmural-extent of the abnormality and (b) picture matching of contours. We found no relationship between the transmural-extent of T2-hyperintense regions and that of the AAR (bright-blood-T2: r=0.06, P=0.69; black-blood-T2: r=0.01, P=0.97). Instead, there was a strong correlation with that of infarction (bright-blood-T2: r=0.94, P<0.0001; black-blood-T2: r=0.95, P<0.0001). Additionally, contour analysis demonstrated a fingerprint match of T2-hyperintense regions with the intricate contour of infarcted regions by delayed-enhancement MRI. Similarly, in patients there was a close correspondence between contours of T2-hyperintense and infarcted regions, and the transmural-extent of these regions were highly correlated (bright-blood-T2: r=0.82, P<0.0001; black-blood-T2: r=0.83, P<0.0001). CONCLUSION: T2-weighted MRI does not depict the AAR. Accordingly, T2-weighted MRI should not be used to measure myocardial salvage, either to inform patient management decisions or to evaluate novel therapies for acute MI.


Assuntos
Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/patologia , Miocárdio/patologia , Adulto , Idoso , Animais , Circulação Coronária , Diagnóstico Diferencial , Cães , Edema/patologia , Determinação de Ponto Final , Feminino , Corantes Fluorescentes , Coração/fisiopatologia , Humanos , Masculino , Microesferas , Pessoa de Meia-Idade , Infarto do Miocárdio/sangue , Infarto do Miocárdio/induzido quimicamente , Infarto do Miocárdio/fisiopatologia , Tamanho do Órgão , Compostos Organometálicos , Estudos Prospectivos , Risco , Troponina T/sangue
12.
Magn Reson Med ; 70(5): 1360-8, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23213005

RESUMO

A versatile method for generating T2 -weighting is a T2 -preparation module, which has been used successfully for cardiac imaging at 1.5T. Although it has been applied at 3T, higher fields (B0 ≥ 3T) can degrade B0 and B1 homogeneity and result in nonuniform magnetization preparation. For cardiac imaging, blood flow and cardiac motion may further impair magnetization preparation. In this study, a novel T2 -preparation module containing multiple adiabatic B1 -insensitive refocusing pulses is introduced and compared with three previously described modules [(a) composite MLEV4, (b) modified BIR-4 (mBIR-4), and (c) Silver-Hoult-pair]. In the static phantom, the proposed module provided similar or better B0 and B1 insensitivity than the other modules. In human subjects (n = 21), quantitative measurement of image signal coefficient of variation, reflecting overall image inhomogeneity, was lower for the proposed module (0.10) than for MLEV4 (0.15, P < 0.0001), mBIR-4 (0.27, P < 0.0001), and Silver-Hoult-pair (0.14, P = 0.001) modules. Similarly, qualitative analysis revealed that the proposed module had the best image quality scores and ranking (both, P < 0.0001). In conclusion, we present a new T2 -preparation module, which is shown to be robust for cardiac imaging at 3T in comparison with existing methods.


Assuntos
Algoritmos , Artefatos , Vasos Coronários/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Velocidade do Fluxo Sanguíneo , Vasos Coronários/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento/fisiologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Res Sq ; 2023 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-37841862

RESUMO

Background: Cardiovascular disease (CVD) remains a leading cause of death in people living with HIV. Myocardial fibrosis is well-described in HIV infection acquired in adulthood. We evaluate the burden of fibrosis by cardiac magnetic resonance in people with perinatal HIV infection. Methods: Individuals with perinatally acquired HIV (pnHIV) diagnosed before 10 years-old and on antiretroviral treatment for ≥ 6 months were matched with uninfected controls. Patients with significant cardiometabolic co-morbidities and pregnancy were excluded. Diffuse fibrosis was assessed by cardiac magnetic resonance (CMR). with native T1 mapping for calculation of extracellular volume fraction (ECV). Viability was assessed with late gadolinium enhancement. The normality of fibrosis was assessed using the Komogrov-Smirnov test. Fibrosis between the groups was analyzed using a Mann-Whitney U test, as the data was not normally distributed. Statistical significance was defined as a p-valve < 0.05. Results: Fourteen adults with pnHIV group and 26 controls (71% female and 86% Black race) were assessed. The average (± standard deviation) age in the study group was 29 (± 4.3) years-old. All pnHIV had been on ART for decades. Demographic data, CMR functional/volumetric data, and pre-contrast T1 mapping values were similar between groups. Diastolic function was normal in 50% of pnHIV patients and indeterminate in most of the remainder (42%). There was no statistically significant difference in ECV between groups; p = 0.24. Conclusion: Perinatally-acquired HIV was not associated with diffuse myocardial fibrosis. Early exposure to ART may be cardioprotective against development of myocardial fibrosis in patients with perinatal HIV.

14.
JACC Cardiovasc Imaging ; 15(12): 2069-2079, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36481075

RESUMO

BACKGROUND: Myocardial fibrosis is a fundamental process in cardiac injury. Cardiac magnetic resonance native T1 mapping has been proposed for diagnosing myocardial fibrosis without the need for gadolinium contrast. However, recent studies suggest that T1 measurements can be erroneous in the presence of intramyocardial fat. OBJECTIVES: The purpose of this study was to investigate whether the presence of fatty metaplasia affects the accuracy of native T1 maps for the diagnosis of myocardial replacement fibrosis in patients with chronic myocardial infarction (MI). METHODS: Consecutive patients (n = 312) with documented chronic MI (>6 months old) and controls without MI (n = 50) were prospectively enrolled. Presence and size of regions with elevated native T1 and infarction were quantitatively determined (mean + 5SD) on modified look-locker inversion-recovery and delayed-enhancement images, respectively, at 3.0-T. The presence of fatty metaplasia was determined using an out-of-phase steady-state free-precession cine technique and further verified with standard fat-water Dixon methods. RESULTS: Native T1 mapping detected chronic MI with markedly higher sensitivity in patients with fatty metaplasia than those without fatty metaplasia (85.6% vs 13.3%) with similar specificity (100% vs 98.9%). In patients with fatty metaplasia, the size of regions with elevated T1 significantly underestimated infarct size and there was a better correlation with fatty metaplasia size than infarct size (r = 0.76 vs r = 0.49). In patients without fatty metaplasia, most of the modest elevation in T1 appeared to be secondary to subchronic infarcts that were 6 to 12 months old; the T1 of infarcts >12 months old was not different from noninfarcted myocardium. CONCLUSIONS: Native T1 mapping is poor at detecting replacement fibrosis but may indirectly detect chronic MI if there is associated fatty metaplasia. Native T1 mapping for the diagnosis and characterization of myocardial fibrosis is unreliable.


Assuntos
Infarto do Miocárdio , Humanos , Lactente , Valor Preditivo dos Testes , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico por imagem , Fibrose
15.
JAMA Cardiol ; 6(10): 1196-1201, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34185046

RESUMO

Importance: Vaccine-associated myocarditis is an unusual entity that has been described for the smallpox vaccine, but only anecdotal case reports have been described for other vaccines. Whether COVID-19 vaccination may be linked to the occurrence of myocarditis is unknown. Objective: To describe a group of 7 patients with acute myocarditis over 3 months, 4 of whom had recent messenger RNA (mRNA) COVID-19 vaccination. Design, Setting, and Participants: All patients referred for cardiovascular magnetic resonance imaging at Duke University Medical Center were asked to participate in a prospective outcomes registry. Two searches of the registry database were performed: first, to identify patients with acute myocarditis for the 3-month period between February 1 and April 30 for 2017 through 2021, and second, to identify all patients with possible vaccine-associated myocarditis for the past 20 years. Once patients with possible vaccine-associated myocarditis were identified, data available in the registry were supplemented by additional data collection from the electronic health record and a telephone interview. Exposures: mRNA COVID-19 vaccine. Main Outcomes and Measures: Occurrence of acute myocarditis by cardiovascular magnetic resonance imaging. Results: In the 3-month period between February 1 and April 30, 2021, 7 patients with acute myocarditis were identified, of which 4 occurred within 5 days of COVID-19 vaccination. Three were younger male individuals (age, 23-36 years) and 1 was a 70-year-old female individual. All 4 had received the second dose of an mRNA vaccine (2 received mRNA-1273 [Moderna], and 2 received BNT162b2 [Pfizer]). All presented with severe chest pain, had biomarker evidence of myocardial injury, and were hospitalized. Coincident testing for COVID-19 and respiratory viruses provided no alternative explanation. Cardiac magnetic resonance imaging findings were typical for myocarditis, including regional dysfunction, late gadolinium enhancement, and elevated native T1 and T2. Conclusions and Relevance: In this study, magnetic resonance imaging findings were found to be consistent with acute myocarditis in 7 patients; 4 of whom had preceding COVID-19 vaccination. Further investigation is needed to determine associations of COVID-19 vaccination and myocarditis.


Assuntos
Vacinas contra COVID-19/efeitos adversos , COVID-19/prevenção & controle , Miocardite/etiologia , Vacinação/estatística & dados numéricos , Vacina de mRNA-1273 contra 2019-nCoV , Doença Aguda , Adulto , Idoso , Vacina BNT162 , COVID-19/diagnóstico , COVID-19/epidemiologia , COVID-19/virologia , Vacinas contra COVID-19/administração & dosagem , Técnicas de Imagem Cardíaca/métodos , Dor no Peito/diagnóstico , Dor no Peito/etiologia , Feminino , Gadolínio/administração & dosagem , Gadolínio/metabolismo , Hospitalização , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Miocardite/diagnóstico , Miocardite/epidemiologia , Avaliação de Resultados em Cuidados de Saúde , Estudos Prospectivos , Sistema de Registros , SARS-CoV-2/genética , Vacinação/métodos , Vacinação/tendências
16.
Int J Cardiol ; 330: 251-258, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33535074

RESUMO

BACKGROUND: Quantitative cardiovascular magnetic resonance T1-mapping is increasingly used for myocardial tissue characterization. However, the lack of standardization limits direct comparability between centers and wider roll-out for clinical use or trials. PURPOSE: To develop a quality assurance (QA) program assuring standardized T1 measurements for clinical use. METHODS: MR phantoms manufactured in 2013 were distributed, including ShMOLLI T1-mapping and reference T1 and T2 protocols. We first studied the T1 and T2 dependency on temperature and phantom aging using phantom datasets from a single site over 4 years. Based on this, we developed a multiparametric QA model, which was then applied to 78 scans from 28 other multi-national sites. RESULTS: T1 temperature sensitivity followed a second-order polynomial to baseline T1 values (R2 > 0.996). Some phantoms showed aging effects, where T1 drifted up to 49% over 40 months. The correlation model based on reference T1 and T2, developed on 1004 dedicated phantom scans, predicted ShMOLLI-T1 with high consistency (coefficient of variation 1.54%), and was robust to temperature variations and phantom aging. Using the 95% confidence interval of the correlation model residuals as the tolerance range, we analyzed 390 ShMOLLI T1-maps and confirmed accurate sequence deployment in 90%(70/78) of QA scans across 28 multiple centers, and categorized the rest with specific remedial actions. CONCLUSIONS: The proposed phantom QA for T1-mapping can assure correct method implementation and protocol adherence, and is robust to temperature variation and phantom aging. This QA program circumvents the need of frequent phantom replacements, and can be readily deployed in multicenter trials.


Assuntos
Cardiomiopatia Hipertrófica , Imageamento por Ressonância Magnética , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Sistema de Registros , Reprodutibilidade dos Testes
17.
Int J Hyperthermia ; 26(7): 725-34, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20849265

RESUMO

PURPOSE: A review of MRI temperature imaging methods based on intermolecular multiple quantum coherences (iMQCs) is presented. Temperature imaging based on iMQCs can provide absolute temperature maps that circumvent the artefacts that other proton frequency shift techniques suffer from such as distortions to the detected temperature due to susceptibility changes and magnetic field inhomogeneities. Thermometry based on iMQCs is promising in high-fat tissues such as the breast, since it relies on the fat signal as an internal reference. This review covers the theoretical background of iMQCs, and the necessary adaptations for temperature imaging using iMQCs. MATERIALS AND METHODS: Data is presented from several papers on iMQC temperature imaging. These studies were done at 7T in both phantoms and in vivo. Results from phantoms of cream (homogeneous mixture of water and fat) are presented as well as in vivo temperature maps in obese mice. RESULTS: Thermometry based on iMQCs offers the potential to provide temperature maps which are free of artefacts due to susceptibility and magnetic field inhomogeneities, and detect temperature on an absolute scale. CONCLUSIONS: The data presented in the papers reviewed highlights the promise of iMQC-based temperature imaging in fatty tissues such as the breast. The change in susceptibility of fat with temperature makes standard proton frequency shift methods (even with fat suppression) challenging and iMQC-based imaging offers an alternative approach.


Assuntos
Imageamento por Ressonância Magnética/métodos , Teoria Quântica , Temperatura
18.
Magn Reson Med ; 61(4): 937-43, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19215050

RESUMO

Intermolecular double quantum coherences (iDQCs), signals that result from simultaneous transitions of two or more separated spins, are known to produce images that are highly sensitive to subvoxel structure, particularly local anisotropy. Here we demonstrate how iDQCs signal can be used to efficiently detect the anisotropy created in breast tumor tissues and prostate tumor tissues by targeted (LHRH-conjugated) superparamagnetic nanoparticles (SPIONs), thereby distinguishing the necrotic area from the surrounding tumor tissue.


Assuntos
Algoritmos , Neoplasias da Mama/diagnóstico , Compostos Férricos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico , Animais , Anisotropia , Linhagem Celular Tumoral , Meios de Contraste , Feminino , Aumento da Imagem/métodos , Magnetismo , Masculino , Camundongos , Camundongos Nus , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
J Chem Phys ; 131(20): 204510, 2009 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-19947697

RESUMO

A recent quantum computing paper (G. S. Uhrig, Phys. Rev. Lett. 98, 100504 (2007)) analytically derived optimal pulse spacings for a multiple spin echo sequence designed to remove decoherence in a two-level system coupled to a bath. The spacings in what has been called a "Uhrig dynamic decoupling (UDD) sequence" differ dramatically from the conventional, equal pulse spacing of a Carr-Purcell-Meiboom-Gill (CPMG) multiple spin echo sequence. The UDD sequence was derived for a model that is unrelated to magnetic resonance, but was recently shown theoretically to be more general. Here we show that the UDD sequence has theoretical advantages for magnetic resonance imaging of structured materials such as tissue, where diffusion in compartmentalized and microstructured environments leads to fluctuating fields on a range of different time scales. We also show experimentally, both in excised tissue and in a live mouse tumor model, that optimal UDD sequences produce different T(2)-weighted contrast than do CPMG sequences with the same number of pulses and total delay, with substantial enhancements in most regions. This permits improved characterization of low-frequency spectral density functions in a wide range of applications.


Assuntos
Meios de Contraste , Reforma dos Serviços de Saúde/ética , Reforma dos Serviços de Saúde/métodos , Imageamento por Ressonância Magnética/tendências , Espectroscopia de Ressonância Magnética/métodos , Animais , Meios de Contraste/química , Reforma dos Serviços de Saúde/organização & administração , Camundongos
20.
JAMA Cardiol ; 4(3): 256-264, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30735566

RESUMO

Importance: Stress cardiac magnetic resonance imaging (CMR) is not widely used in current clinical practice, and its ability to predict patient mortality is unknown. Objective: To determine whether stress CMR is associated with patient mortality. Design, Setting, and Participants: Real-world evidence from consecutive clinically ordered CMR examinations. Multicenter study of patients undergoing clinical evaluation of myocardial ischemia. Patients with known or suspected coronary artery disease (CAD) underwent clinical vasodilator stress CMR at 7 different hospitals. An automated process collected data from the finalized clinical reports, deidentified and aggregated the data, and assessed mortality using the US Social Security Death Index. Main Outcomes and Measures: All-cause patient mortality. Results: Of the 9151 patients, the median (interquartile range) patient age was 63 (51-70) years, 55% were men, and the median (interquartile range) body mass index was 29 (25-33) (calculated as weight in kilograms divided by height in meters squared). The multicenter automated process yielded 9151 consecutive patients undergoing stress CMR, with 48 615 patient-years of follow-up. Of these patients, 4408 had a normal stress CMR examination, 4743 had an abnormal examination, and 1517 died during a median follow-up time of 5.0 years. Using multivariable analysis, addition of stress CMR improved prediction of mortality in 2 different risk models (model 1 hazard ratio [HR], 1.83; 95% CI, 1.63-2.06; P < .001; model 2: HR, 1.80; 95% CI, 1.60-2.03; P < .001) and also improved risk reclassification (net improvement: 11.4%; 95% CI, 7.3-13.6; P < .001). After adjustment for patient age, sex, and cardiac risk factors, Kaplan-Meier survival analysis showed a strong association between an abnormal stress CMR and mortality in all patients (HR, 1.883; 95% CI, 1.680-2.112; P < .001), patients with (HR, 1.955; 95% CI, 1.712-2.233; P < .001) and without (HR, 1.578; 95% CI, 1.235-2.2018; P < .001) a history of CAD, and patients with normal (HR, 1.385; 95% CI, 1.194-1.606; P < .001) and abnormal left ventricular ejection fraction (HR, 1.836; 95% CI, 1.299-2.594; P < .001). Conclusions and Relevance: Clinical vasodilator stress CMR is associated with patient mortality in a large, diverse population of patients with known or suspected CAD as well as in multiple subpopulations defined by history of CAD and left ventricular ejection fraction. These findings provide a foundational motivation to study the comparative effectiveness of stress CMR against other modalities.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Teste de Esforço/métodos , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico por imagem , Vasodilatadores/administração & dosagem , Idoso , Índice de Massa Corporal , Doença da Artéria Coronariana/tratamento farmacológico , Doença da Artéria Coronariana/fisiopatologia , Teste de Esforço/mortalidade , Feminino , Seguimentos , Coração/fisiopatologia , Humanos , Imageamento por Ressonância Magnética/mortalidade , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Valor Preditivo dos Testes , Fatores de Risco , Volume Sistólico/fisiologia , Análise de Sobrevida , Função Ventricular Esquerda/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA