1.
Cell ; 169(6): 1029-1041.e16, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28575667

RESUMO

We report a noninvasive strategy for electrically stimulating neurons at depth. By delivering to the brain multiple electric fields at frequencies too high to recruit neural firing, but which differ by a frequency within the dynamic range of neural firing, we can electrically stimulate neurons throughout a region where interference between the multiple fields results in a prominent electric field envelope modulated at the difference frequency. We validated this temporal interference (TI) concept via modeling and physics experiments, and verified that neurons in the living mouse brain could follow the electric field envelope. We demonstrate the utility of TI stimulation by stimulating neurons in the hippocampus of living mice without recruiting neurons of the overlying cortex. Finally, we show that by altering the currents delivered to a set of immobile electrodes, we can steerably evoke different motor patterns in living mice.


Assuntos
Estimulação Encefálica Profunda/métodos , Estimulação Transcraniana por Corrente Contínua/métodos , Animais , Estimulação Encefálica Profunda/efeitos adversos , Estimulação Encefálica Profunda/instrumentação , Eletrodos , Hipocampo/fisiologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Neurônios/fisiologia , Estimulação Transcraniana por Corrente Contínua/efeitos adversos , Estimulação Transcraniana por Corrente Contínua/instrumentação
2.
Nature ; 563(7729): 65-71, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30382197

RESUMO

Spinal cord injury leads to severe locomotor deficits or even complete leg paralysis. Here we introduce targeted spinal cord stimulation neurotechnologies that enabled voluntary control of walking in individuals who had sustained a spinal cord injury more than four years ago and presented with permanent motor deficits or complete paralysis despite extensive rehabilitation. Using an implanted pulse generator with real-time triggering capabilities, we delivered trains of spatially selective stimulation to the lumbosacral spinal cord with timing that coincided with the intended movement. Within one week, this spatiotemporal stimulation had re-established adaptive control of paralysed muscles during overground walking. Locomotor performance improved during rehabilitation. After a few months, participants regained voluntary control over previously paralysed muscles without stimulation and could walk or cycle in ecological settings during spatiotemporal stimulation. These results establish a technological framework for improving neurological recovery and supporting the activities of daily living after spinal cord injury.


Assuntos
Tecnologia Biomédica , Terapia por Estimulação Elétrica , Paralisia/reabilitação , Traumatismos da Medula Espinal/reabilitação , Caminhada/fisiologia , Atividades Cotidianas , Simulação por Computador , Eletromiografia , Espaço Epidural , Humanos , Perna (Membro)/inervação , Perna (Membro)/fisiologia , Perna (Membro)/fisiopatologia , Locomoção/fisiologia , Masculino , Neurônios Motores/fisiologia , Músculo Esquelético/inervação , Músculo Esquelético/fisiologia , Músculo Esquelético/fisiopatologia , Paralisia/fisiopatologia , Paralisia/cirurgia , Medula Espinal/citologia , Medula Espinal/fisiologia , Medula Espinal/fisiopatologia , Traumatismos da Medula Espinal/fisiopatologia , Traumatismos da Medula Espinal/cirurgia
3.
PLoS Comput Biol ; 17(10): e1009460, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34710086

RESUMO

Fifth generation networks (5G) will be associated with a partial shift to higher carrier frequencies, including wavelengths comparable in size to insects. This may lead to higher absorption of radio frequency (RF) electromagnetic fields (EMF) by insects and could cause dielectric heating. The yellow fever mosquito (Aedes aegypti), a vector for diseases such as yellow and dengue fever, favors warm climates. Being exposed to higher frequency RF EMFs causing possible dielectric heating, could have an influence on behavior, physiology and morphology, and could be a possible factor for introduction of the species in regions where the yellow fever mosquito normally does not appear. In this study, the influence of far field RF exposure on A. aegypti was examined between 2 and 240 GHz. Using Finite Difference Time Domain (FDTD) simulations, the distribution of the electric field in and around the insect and the absorbed RF power were found for six different mosquito models (three male, three female). The 3D models were created from micro-CT scans of real mosquitoes. The dielectric properties used in the simulation were measured from a mixture of homogenized A. aegypti. For a given incident RF power, the absorption increases with increasing frequency between 2 and 90 GHz with a maximum between 90 and 240 GHz. The absorption was maximal in the region where the wavelength matches the size of the mosquito. For a same incident field strength, the power absorption by the mosquito is 16 times higher at 60 GHz than at 6 GHz. The higher absorption of RF power by future technologies can result in dielectric heating and potentially influence the biology of this mosquito.


Assuntos
Aedes , Mosquitos Vetores , Ondas de Rádio , Aedes/fisiologia , Aedes/efeitos da radiação , Animais , Feminino , Temperatura Alta , Masculino , Mosquitos Vetores/fisiologia , Mosquitos Vetores/efeitos da radiação , Febre Amarela/transmissão
4.
Int J Hyperthermia ; 39(1): 758-771, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35654473

RESUMO

PURPOSE: Healthy tissue hotspots are a main limiting factor in administering deep hyperthermia cancer therapy. We propose an optimization scheme that uses time-multiplexed steering (TMPS) among minimally correlated (nearly) Pareto-optimal solutions to suppress hotspots without reducing tumor heating. Furthermore, tumor heating homogeneity is maximized, thus reducing toxicity and avoiding underexposed tumor regions, which in turn may reduce recurrence. MATERIALS AND METHODS: The novel optimization scheme combines random generation of steering parameters with local optimization to efficiently identify the set of (Pareto-) optimal solutions of conflicting optimization goals. To achieve simultaneous suppression of hotspots, multiple steering parameter configurations with minimally correlated hotspots are selected near the Pareto front and combined in TMPS. The performance of the novel scheme was compared with that of a multi-goal Genetic Algorithm for a range of simulated treatment configurations involving a modular applicator heating a generic tumor situated in the bladder, cervix, or pelvic bone. SAR cumulative histograms in tumor and healthy tissue, as well as hotspot volumes are used as metrics. RESULTS: Compared to the non-TMPS optimization, the proposed scheme was able to reduce the peak temperature in healthy tissue by 0.2 °C-1.0 °C (a thermal dose reduction by at least 26%) and, importantly, the hotspot volume above 42 °C in healthy tissue by 41%-86%. At the same time, tumor heating homogeneity was maintained or improved. CONCLUSIONS: The extremely rapid optimization (5 s for TMPS part, on a standard PC) permits closed-loop treatment reoptimization during treatment administration, and empowers physicians with a selection of optimal treatment scenarios reflecting different weighting of conflicting treatment goals.


Assuntos
Objetivos , Hipertermia Induzida , Feminino , Calefação , Humanos , Hipertermia
5.
Bioelectromagnetics ; 43(7): 404-412, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36335604

RESUMO

This study investigates the absorption of the induced E-field in homogeneous biological tissue exposed to highly localized field sources in proximity of the body, such as the charged tips of antennas, where E-field coupling dominates. These conditions are relevant for compliance testing of modern mobile phones where exposure is evaluated at small separation between radiators and the body. We derive an approximation that characterizes the decay of the induced E-field in the tissue as a function of distance. The absorption is quantified in terms of the local specific absorption rate (SAR) at the tissue surface as a function of the charge at the antenna tip. The approximation is based on the analytical evaluation of the E-fields of a charged disk under quasi-static conditions. We validate this approximation using full-wave simulations of dipoles. We demonstrate that the coupling mechanism of the E-field is dominated by the perpendicular field component and that wave propagation need not be considered for the characterization of the exposure. The surface SAR decreases approximately with the fourth power of the distance and with the square of the ratio of the permittivities of the tissue and free-space. The approximation predicts the induced maximum E-field with an accuracy of better than 1.5 dB. © 2022 Bioelectromagnetics Society.


Assuntos
Telefone Celular , Campos Eletromagnéticos , Ondas de Rádio
6.
Magn Reson Med ; 86(4): 2156-2164, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34080721

RESUMO

PURPOSE: The risks of RF-induced heating of active implantable medical device (AIMD) leads during MR examinations must be well understood and realistically assessed. In this study, we evaluate the potential additional risks of broken and abandoned (cut) leads. METHODS: First, we defined a generic AIMD with a metallic implantable pulse generator (IPG) and a 100-cm long lead containing 1 or 2 wires. Next, we numerically estimated the deposited in vitro lead-tip power for an intact lead, as well as with wire breaks placed at 10 cm intervals. We studied the effect of the break size (wire gap width), as well as the presence of an intact wire parallel to the broken wire, and experimentally validated the numeric results for the configurations with maximum deposited in vitro lead-tip power. Finally, we performed a Tier 3 assessment of the deposited in vivo lead-tip power for the intact and broken lead in 4 high resolution virtual population anatomic models for over 54,000 MR examination scenarios. RESULTS: The enhancement of the deposited lead-tip power for the broken leads, compared to the intact lead, reached 30-fold in isoelectric exposure, and 16-fold in realistic clinical exposures. The presence of a nearby intact wire, or even a nearby broken wire, reduced this enhancement factor to <7-fold over the intact lead. CONCLUSION: Broken and abandoned leads can pose increased risk of RF-induced lead-tip heating to patients undergoing MR examinations. The potential enhancement of deposited in vivo lead-tip power depends on location and type of the wire break, lead design, and clinical routing of the lead, and should be carefully considered when performing risk assessment for MR examinations and MR conditional labeling.


Assuntos
Calefação , Imageamento por Ressonância Magnética , Temperatura Alta , Humanos , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Próteses e Implantes/efeitos adversos , Ondas de Rádio/efeitos adversos
7.
Bioelectromagnetics ; 42(6): 484-490, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34130354

RESUMO

The introduction of new dosimetric quantities, in particular, epithelial or absorbed power density for frequencies above 6 GHz, in exposure guidelines and safety standards requires the development of new experimental assessment procedures for compliance testing. In this study, we propose to approximate the peak spatial-average absorbed power density (psSab ) using the same measured data and algorithms that are used for determining the peak spatial-average specific absorption rate psSAR, which is currently limited to frequencies up to 10 GHz. The uncertainty component for the transformation of psSAR to psSab was evaluated as less than 0.55 dB (13.5%) for any source as close as 0.02 λ from the tissue simulating media. The approach is easy to implement and allows determining compliance with the basic restrictions of the latest safety guidelines. In the next project, we will expand dosimetric probes, phantoms, and procedures for frequencies above 10 GHz. © 2021 Bioelectromagnetics Society.


Assuntos
Campos Eletromagnéticos , Radiometria , Algoritmos , Imagens de Fantasmas
8.
Bioelectromagnetics ; 42(7): 562-574, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34289515

RESUMO

Several recent theoretical dosimetric studies above 6 GHz apply generic layered skin models. For this frequency range, new experimental phantoms for over-the-air performance of wireless devices were proposed that simulate the impedance matching effects of the stratum corneum layer (SCL) with a low-loss coating layer. The aim of this study was to verify the skin models by comparing their reflection coefficients S11 with measurements of 37 human volunteers (21 males, 16 females, 5-80 years) at 21 body locations (10 at palm, 11 at arm/face) with different SCL thicknesses, using waveguides covering frequencies from 40 to 110 GHz. Such measurements were also carried out with the phantom material. The statistical analysis showed strong evidence that S11 depends on the SCL thickness and no evidence that S11 depends on sex. The measured S11 values for thin and thick skin can be represented by SCL layers of 15 and 140 µm, respectively. These values correspond well to the assumptions of previous studies. (The cohort did not include volunteers doing heavy manual work.) The phantom material mimics the matching effect of the SCL with deviations from the waveguide measurements of less than 0.85 dB (22%), which confirms the suitability of layered phantoms to represent the electromagnetic reflection/absorption of human skin. © 2021 Bioelectromagnetics Society.


Assuntos
Fenômenos Eletromagnéticos , Pele , Feminino , Humanos , Masculino , Modelos Teóricos , Imagens de Fantasmas , Radiometria
9.
Bioelectromagnetics ; 41(2): 164-168, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31885092

RESUMO

Both the current and newly proposed safety guidelines for local human exposure to millimeter-wave frequencies aim at restricting the maximum local temperature increase in the skin to prevent tissue damage. In this study, we show that the application of the current and proposed limits for pulsed fields can lead to a temperature increase of 10°C for short pulses and frequencies between 6 and 30 GHz. We also show that the proposed averaging area of 4 cm2 , that is greatly reduced compared with the current limits, does not prevent high-temperature increases in the case of narrow beams. A realistic Gaussian beam profile with a 1 mm radius can result in a temperature increase about 10 times higher than the 0.4°C increase the same averaged power density would produce for a plane wave. In the case of pulsed narrow beams, the values for the time and spatial-averaged power density allowed by the proposed new guidelines could result in extreme temperature increases. Bioelectromagnetics. 2020;41:164-168. © 2019 Bioelectromagnetics Society.


Assuntos
Campos Eletromagnéticos , Exposição à Radiação/análise , Temperatura Corporal , Campos Eletromagnéticos/efeitos adversos , Humanos , Perfusão , Temperatura , Fatores de Tempo
10.
Bioelectromagnetics ; 41(5): 348-359, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32410291

RESUMO

The most recent safety guidelines define basic restrictions for electromagnetic field exposure at frequencies more than 6 GHz in terms of spatial- and time-averaged transmitted power density inside the body. To enable easy-to-perform evaluations in situ, the reference levels for the incident power density were derived. In this study, we examined whether compliance with the reference levels always ensures compliance with basic restrictions. This was evaluated at several distances from different antennas (dipole, loop, slot, patch, and helix). Three power density definitions based on integration of the perpendicular real part of the Poynting vector, the real part of its three vector components, and its modulus were compared for averaging areas of λ2 /16, 4 cm2 (below 30 GHz) and 1 cm2 (30 GHz). In the reactive near-field (d < λ/(2π)), the transmitted power density can be underestimated if an antenna operates at the free space exposure limit. This underestimation may exceed 6 dB (4.0 times) and depends on the field source due to different coupling mechanisms. It is frequency-dependent for fixed-size averaging areas (4 and 1 cm2 ). At larger distances, transmission can be larger than the theoretical plane-wave transmission coefficient due to backscattering between the body and field source. Using the modulus of the incident Poynting vector yields the smallest underestimation. © 2020 Bioelectromagnetics Society.


Assuntos
Campos Eletromagnéticos , Fenômenos Físicos , Análise Espaço-Temporal
11.
Bioelectromagnetics ; 40(6): 422-433, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31325162

RESUMO

Standard risk evaluations posed by medical implants during magnetic resonance imaging (MRI) includes (i) the assessment of the total local electromagnetic (EM) power (P) absorbed in the vicinity of the electrodes and (ii) the translation of P into a local in vivo tissue temperature increase ∆T (P2∆T) in animal experiments or simulations. We investigated the implant/tissue modeling requirements and associated uncertainties by applying full-wave EM and linear bioheat solvers to different implant models, incident field conditions, electrode configurations, and tissue models. Results show that the magnitude of the power is predominately determined by the lead, while the power distribution, and the P2∆T conversion, is determined by the electrode and surrounding tissues. P2∆T is strongly dependent on the size of the electrode, tissue type in contact with the electrode, and tissue inhomogeneity (factor of >2 each) but less on the modeling of the lead (<±10%) and incident field distribution along the lead (<±20%). This was confirmed by means of full-wave simulations performed with detailed high-resolution anatomical phantoms exposed to two commonly used MRI clinical scenarios (64 and 128 MHz), resulting in differences of less than 6%. For the determination of P2∆T, only the electrode and surrounding tissues must be modeled in great detail, whereas the lead can be modeled as a computationally efficient simplified structure exposed to a uniform field. The separate assessments of lead and electrode reduce the overall computational effort by several orders of magnitude. The errors introduced by this simplification can be considered by uncertainty terms. Bioelectromagnetics. 2019;40:422-433. © 2019 Bioelectromagnetics Society.


Assuntos
Eletrodos Implantados , Hipertermia Induzida/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Próteses e Implantes , Simulação por Computador , Temperatura Alta , Modelos Biológicos , Ondas de Rádio
12.
Bioelectromagnetics ; 40(7): 458-471, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31396987

RESUMO

The Virtual Population (ViP) phantoms have been used in many dosimetry studies, yet, to date, anatomical phantom uncertainty in radiofrequency (RF) research has largely been neglected. The objective of this study is to gain insight, for the first time, regarding the uncertainty in RF-induced fields during magnetic resonance imaging associated with tissue assignment and segmentation quality and consistency in anatomical phantoms by evaluating the differences between two generations of ViP phantoms, ViP1.x and ViP3.0. The RF-induced 10g-average electric (E-) fields, tangential E-fields distribution along active implantable medical devices (AIMD) routings, and estimated AIMD heating were compared for five phantoms that are part of both ViP1.x and ViP3.0. The results demonstrated that differences exceeded 3 dB (-29%, +41%) for local quantities and 1 dB (±12% for field, ±25% for power) for integrated and volume-averaged quantities (e.g., estimated AIMD-heating and 10 g-average E-fields), while the variation across different ViP phantoms of the same generation can exceed 10 dB (-68% and +217% for field, -90% and +900% for power). In conclusion, the anatomical phantom uncertainty associated with tissue assignment and segmentation quality/consistency is larger than previously assumed, i.e., 0.6 dB or ±15% (k = 1) for AIMD heating. Further, multiple phantoms based on different volunteers covering the target population are required for quantitative analysis of dosimetric endpoints, e.g., AIMD heating, which depend on patient anatomy. Phantoms with the highest fidelity in tissue assignment and segmentation should be used, as these ensure the lowest uncertainty and possible underestimation of exposure. To verify that the uncertainty decreases monotonically with improved phantom quality, the evaluation of differences between phantom generations should be repeated for any improvement in segmentation. Bioelectromagnetics. 2019;40:458-471. © 2019 Bioelectromagnetics Society.


Assuntos
Simulação por Computador , Metais/metabolismo , Modelos Anatômicos , Próteses e Implantes/efeitos adversos , Radiação Eletromagnética , Desenho de Equipamento , Segurança de Equipamentos , Humanos
13.
Bioelectromagnetics ; 40(5): 343-353, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31157932

RESUMO

Exposure to extremely low-frequency magnetic fields (ELF-MFs) has been classified by the International Agency for Research on Cancer (IARC) as "possibly carcinogenic to humans," based on limited scientific evidence concerning childhood leukemia. This assessment emphasized the lack of appropriate animal models recapitulating the natural history of this disease. Childhood B-cell acute lymphoblastic leukemia (B-ALL) is the result of complex interactions between genetic susceptibility and exposure to exogenous agents. The most common chromosomal alteration is the ETV6-RUNX1 fusion gene, which confers a low risk of developing the malignancy by originating a preleukemic clone requiring secondary hits for full-blown disease to appear. To develop potential prophylactic interventions, we need to identify the environmental triggers of the second hit. Recently, we generated a B-ALL mouse model of the human ETV6-RUNX1+ preleukemic state. Here, we present the results from the ARIMMORA pilot study, obtained by exposing 34 Sca1-ETV6-RUNX1 mice (vs. 27 unexposed) to a 50 Hz magnetic field of 1.5 mT with both fundamental and harmonic content, with an on/off cycle of 10 min/5 min, for 20 h/day, from conception until 3 months of age. Mice were monitored until 2 years of age and peripheral blood was periodically analyzed by flow cytometry. One of the exposed mice developed B-ALL while none of the non-exposed did. Although the results are statistically non-significant due to the limited number of mice used in this pilot experiment, overall, the results show that the newly developed Sca1-ETV6-RUNX1 mouse can be successfully used for ELF-MF exposure studies about the etiology of childhood B-ALL. Bioelectromagnetics. 2019;40:343-353. © 2019 Bioelectromagnetics Society.


Assuntos
Subunidade alfa 2 de Fator de Ligação ao Core/genética , Modelos Animais de Doenças , Campos Eletromagnéticos/efeitos adversos , Leucemia Experimental , Leucemia-Linfoma Linfoblástico de Células Precursoras , Proteínas Proto-Oncogênicas c-ets/genética , Ondas de Rádio/efeitos adversos , Proteínas Repressoras/genética , Animais , Subunidade alfa 2 de Fator de Ligação ao Core/metabolismo , Feminino , Humanos , Leucemia Experimental/genética , Leucemia Experimental/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Projetos Piloto , Leucemia-Linfoma Linfoblástico de Células Precursoras/etiologia , Leucemia-Linfoma Linfoblástico de Células Precursoras/genética , Leucemia-Linfoma Linfoblástico de Células Precursoras/metabolismo , Proteínas Proto-Oncogênicas c-ets/metabolismo , Proteínas Repressoras/metabolismo , Variante 6 da Proteína do Fator de Translocação ETS
14.
Bioelectromagnetics ; 39(8): 617-630, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30383885

RESUMO

The objective of this paper is to determine a maximum averaging area for power density (PD) that limits the maximum temperature increase to a given threshold for frequencies above 6 GHz. This maximum area should be conservative for any transmitter at any distance >2 mm from the primary transmitting antennas or secondary field-generating sources. To derive a generically valid maximum averaging area, an analytical approximation for the peak temperature increase caused by localized exposure was derived. The results for a threshold value of 1 K temperature rise were validated against simulations of a series of sources composed of electrical and magnetic elements (dipoles, slots, patches, and arrays) that represented the spectrum of relevant transmitters. The validation was successful for frequencies in which the power deposition occurred superficially (i.e., >10 GHz). In conclusion, the averaging area for a PD limit of 10 W/m2 that conservatively limits the temperature increase in the skin to less than 1 K at any distance >2 mm from the transmitters is frequency dependent, increases with distance, and ranges from 3 cm2 at <10 GHz to 1.9 cm2 at 100 GHz. In the far-field, the area depends additionally on distance and the antenna array aperture. The correlation was found to be worse at lower frequencies (<10 GHz) and very close to the source, the systematic evaluation of which is part of another study to investigate the effect of different coupling mechanisms in the reactive near-field on the ratio of temperature increase to incident power density. The presented model can be directly applied to any other PD and temperature thresholds. Bioelectromagnetics. 39:617-630, 2018. © 2018 Wiley Periodicals, Inc.


Assuntos
Campos Eletromagnéticos , Modelos Teóricos , Exposição à Radiação/análise , Humanos , Pele/efeitos da radiação , Temperatura
15.
Bioelectromagnetics ; 39(3): 190-199, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29537695

RESUMO

Radiofrequency radiation (RFR) causes heating, which can lead to detrimental biological effects. To characterize the effects of RFR exposure on body temperature in relation to animal size and pregnancy, a series of short-term toxicity studies was conducted in a unique RFR exposure system. Young and old B6C3F1 mice and young, old, and pregnant Harlan Sprague-Dawley rats were exposed to Global System for Mobile Communication (GSM) or Code Division Multiple Access (CDMA) RFR (rats = 900 MHz, mice = 1,900 MHz) at specific absorption rates (SARs) up to 12 W/kg for approximately 9 h a day for 5 days. In general, fewer and less severe increases in body temperature were observed in young than in older rats. SAR-dependent increases in subcutaneous body temperatures were observed at exposures ≥6 W/kg in both modulations. Exposures of ≥10 W/kg GSM or CDMA RFR induced excessive increases in body temperature, leading to mortality. There was also a significant increase in the number of resorptions in pregnant rats at 12 W/kg GSM RFR. In mice, only sporadic increases in body temperature were observed regardless of sex or age when exposed to GSM or CDMA RFR up to 12 W/kg. These results identified SARs at which measurable RFR-mediated thermal effects occur, and were used in the selection of exposures for subsequent toxicology and carcinogenicity studies. Bioelectromagnetics. 39:190-199, 2018. © 2018 The Authors. Bioelectromagnetics Published by Wiley Periodicals, Inc.


Assuntos
Temperatura Corporal/efeitos da radiação , Telefone Celular , Exposição à Radiação/efeitos adversos , Ondas de Rádio/efeitos adversos , Envelhecimento/fisiologia , Animais , Feminino , Camundongos , Projetos Piloto , Gravidez , Ratos , Ratos Sprague-Dawley
16.
Cell Physiol Biochem ; 43(4): 1533-1546, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29035881

RESUMO

BACKGROUND/AIMS: Results from recent studies suggest that extremely low frequency magnetic fields (ELF-MF) interfere with intracellular signaling pathways related to proliferative control. The mitogen-activated protein kinases (MAPKs), central signaling components that regulate essentially all stimulated cellular processes, include the extracellular signal-regulated kinases 1/2 (ERK1/2) that are extremely sensitive to extracellular cues. Anti-phospho-ERK antibodies serve as a readout for ERK1/2 activation and are able to detect minute changes in ERK stimulation. The objective of this study was to explore whether activation of ERK1/2 and other signaling cascades can be used as a readout for responses of a variety of cell types, both transformed and non-transformed, to ELF-MF. METHODS: We applied ELF-MF at various field strengths and time periods to eight different cell types with an exposure system housed in a tissue culture incubator and followed the phosphorylation of MAPKs and Akt by western blotting. RESULTS: We found that the phosphorylation of ERK1/2 is increased in response to ELF-MF. However, the phosphorylation of ERK1/2 is likely too low to induce ELF-MF-dependent proliferation or oncogenic transformation. The p38 MAPK was very slightly phosphorylated, but JNK or Akt were not. The effect on ERK1/2 was detected for exposures to ELF-MF strengths as low as 0.15 µT and was maximal at ∼10 µT. We also show that ERK1/2 phosphorylation is blocked by the flavoprotein inhibitor diphenyleneiodonium, indicating that the response to ELF-MF may be exerted via NADP oxidase similar to the phosphorylation of ERK1/2 in response to microwave radiation. CONCLUSIONS: Our results further indicate that cells are responsive to ELF-MF at field strengths much lower than previously suspected and that the effect may be mediated by NADP oxidase. However, the small increase in ERK1/2 phosphorylation is probably insufficient to affect proliferation and oncogenic transformation. Therefore, the results cannot be regarded as proof of the involvement of ELF-MF in cancer in general or childhood leukemia in particular.


Assuntos
Campos Eletromagnéticos , Ativação Enzimática , Sistema de Sinalização das MAP Quinases , Animais , Linhagem Celular , Linhagem Celular Tumoral , Campos Eletromagnéticos/efeitos adversos , Humanos , Proteína Quinase 1 Ativada por Mitógeno/metabolismo , Proteína Quinase 3 Ativada por Mitógeno/metabolismo , NADPH Oxidases/metabolismo , Neoplasias/etiologia , Neoplasias/metabolismo , Fosforilação
17.
Magn Reson Med ; 77(5): 2048-2056, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27174499

RESUMO

PURPOSE: MRI is increasingly used to scan pregnant patients. We investigated the effect of 3 Tesla (T) two-port radiofrequency (RF) shimming in anatomical pregnant women models. THEORY AND METHODS: RF shimming improves B1+ uniformity, but may at the same time significantly alter the induced current distribution and result in large changes in both the level and location of the absorbed RF energy. In this study, we evaluated the electrothermal exposure of pregnant women in the third, seventh, and ninth month of gestation at various imaging landmarks in RF body coils, including modes with RF shimming. RESULTS: Although RF shimmed configurations may lower the local RF exposure for the mother, they can increase the thermal load on the fetus. In worst-case configurations, whole-body exposure and local peak temperatures-up to 40.8°C-are equal in fetus and mother. CONCLUSIONS: Two-port RF shimming can significantly increase the fetal exposure in pregnant women, requiring further research to derive a very robust safety management. For the time being, restriction to the CP mode, which reduces fetal SAR exposure compared with linear-horizontal polarization modes, may be advisable. Results from this study do not support scanning pregnant patients above the normal operating mode. Magn Reson Med 77:2048-2056, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Complicações na Gravidez/prevenção & controle , Lesões por Radiação/prevenção & controle , Proteção Radiológica/métodos , Ondas de Rádio , Algoritmos , Simulação por Computador , Feminino , Temperatura Alta , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Recém-Nascido , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Gravidez , Software
18.
IEEE Trans Electromagn Compat ; 59(4): 1041-1052, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29217848

RESUMO

In this paper we present the novel design features, their technical implementation, and an evaluation of the radio Frequency (RF) exposure systems developed for the National Toxicology Program (NTP) of the National Institute of Environmental Health Sciences (NIEHS) studies on the potential toxicity and carcinogenicity of 2nd and 3rd generation mobile-phone signals. The system requirements for this 2-year NTP cancer bioassay study were the tightly-controlled lifetime exposure of rodents (1568 rats and 1512 mice) to three power levels plus sham simulating typical daily, and higher, exposures of users of GSM and CDMA (IS95) signals. Reverberation chambers and animal housing were designed to allow extended exposure time per day for free-roaming individually-housed animals. The performance of the chamber was characterized in terms of homogeneity, stirred to unstirred energy, efficiency. The achieved homogeneity was 0.59 dB and 0.48 dB at 900 and 1900 MHz respectively. The temporal variation in the electric field strength was optimized to give similar characteristics to that of the power control of a phone in a real network using the two stirrers. Experimental dosimetry was performed to validate the SAR sensitivity and determine the SAR uniformity throughout the exposure volume; SAR uniformities of 0.46 dB and 0.40 dB, respectively, for rats and mice were achieved.

19.
IEEE Trans Electromagn Compat ; 59(6): 1798-1808, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29217849

RESUMO

In this paper, we present the detailed life-time dosimetry analysis for rodents exposed in the reverberation exposure system designed for the two-year cancer bioassay study conducted by the National Toxicology Program of the National Institute of Environmental Health Sciences. The study required the well-controlled and characterized exposure of individually housed, unrestrained mice at 1900 MHz and rats at 900 MHz, frequencies chosen to give best uniformity exposure of organs and tissues. The wbSAR, the peak spatial SAR and the organ specific SAR as well as the uncertainty and variation due to the exposure environment, differences in the growth rates, and animal posture were assessed. Compared to the wbSAR, the average exposure of the high-water-content tissues (blood, heart, lung) were higher by ~4 dB, while the low-loss tissues (bone and fat) were less by ~9 dB. The maximum uncertainty over the exposure period for the SAR was estimated to be <49% (k=2) for the rodents whereas the relative uncertainty between the group was <14% (k=1). The instantaneous variation (averaged over 1 min) was <13% (k=1), which is small compared to other long term exposure research projects. These detailed dosimetric results empowers comparison with other studies and provides a reference for studies of long-term biological effects of exposure of rodents to RF energy.

20.
Magn Reson Med ; 76(3): 986-97, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-26400841

RESUMO

PURPOSE: To assess the effect of radiofrequency (RF) shimming of a 3 Tesla (T) two-port body coil on B1 + uniformity, the local specific absorption rate (SAR), and the local temperature increase as a function of the thermoregulatory response. METHODS: RF shimming alters induced current distribution, which may result in large changes in the level and location of absorbed RF energy. We investigated this effect with six anatomical human models from the Virtual Population in 10 imaging landmarks and four RF coils. Three thermoregulation models were applied to estimate potential local temperature increases, including a newly proposed model for impaired thermoregulation. RESULTS: Two-port RF shimming, compared to circular polarization mode, can increase the B1 + uniformity on average by +32%. Worst-case SAR excitations increase the local RF power deposition on average by +39%. In the first level controlled operating mode, induced peak temperatures reach 42.5°C and 45.6°C in patients with normal and impaired thermoregulation, respectively. CONCLUSION: Image quality with 3T body coils can be significantly increased by RF shimming. Exposure in realistic scan scenarios within guideline limits can be considered safe for a broad patient population with normal thermoregulation. Patients with impaired thermoregulation should not be scanned outside of the normal operating mode. Magn Reson Med 76:986-997, 2016. © 2015 Wiley Periodicals, Inc.


Assuntos
Absorção de Radiação/fisiologia , Tamanho Corporal/fisiologia , Regulação da Temperatura Corporal/fisiologia , Imageamento por Ressonância Magnética/métodos , Modelos Biológicos , Exposição à Radiação/análise , Temperatura Corporal/fisiologia , Temperatura Corporal/efeitos da radiação , Simulação por Computador , Humanos , Exposição à Radiação/prevenção & controle , Ondas de Rádio
SELEÇÃO DE REFERÊNCIAS