Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 142
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 34(7): 4261-4272, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38114847

RESUMO

OBJECTIVES: To compare cardiac computed tomography (CCT) and cardiac magnetic resonance (CMR) for the quantitative assessment of the left ventricular (LV) trabeculated layer in patients with suspected noncompaction cardiomyopathy (NCCM). MATERIALS AND METHODS: Subjects with LV excessive trabeculation who underwent both CMR and CCT imaging as part of the prospective international multicenter NONCOMPACT clinical study were included. For each subject, short-axis CCT and CMR slices were matched. Four quantitative metrics were estimated: 1D noncompacted-to-compacted ratio (NCC), trabecular-to-myocardial area ratio (TMA), trabecular-to-endocardial cavity area ratio (TCA), and trabecular-to-myocardial volume ratio (TMV). In 20 subjects, end-diastolic and mid-diastolic CCT images were compared for the quantification of the trabeculated layer. Relationships between the metrics were investigated using linear regression models and Bland-Altman analyses. RESULTS: Forty-eight subjects (49.9 ± 12.8 years; 28 female) were included in this study. NCC was moderately correlated (r = 0.62), TMA and TMV were strongly correlated (r = 0.78 and 0.78), and TCA had excellent correlation (r = 0.92) between CMR and CCT, with an underestimation bias from CCT of 0.3 units, and 5.1, 4.8, and 5.4 percent-points for the 4 metrics, respectively. TMA, TCA, and TMV had excellent correlations (r = 0.93, 0.96, 0.94) and low biases (- 3.8, 0.8, - 3.8 percent-points) between the end-diastolic and mid-diastolic CCT images. CONCLUSIONS: TMA, TCA, and TMV metrics of the LV trabeculated layer in patients with suspected NCCM demonstrated high concordance between CCT and CMR images. TMA and TCA were highly reproducible and demonstrated minimal differences between mid-diastolic and end-diastolic CCT images. CLINICAL RELEVANCE STATEMENT: The results indicate similarity of CCT to CMR for quantifying the LV trabeculated layer, and the small differences in quantification between end-diastole and mid-diastole demonstrate the potential for quantifying the LV trabeculated layer from clinically performed coronary CT angiograms. KEY POINTS: • Data on cardiac CT for quantifying the left ventricular trabeculated layer are limited. • Cardiac CT yielded highly reproducible metrics of the left ventricular trabeculated layer that correlated well with metrics defined by cardiac MR. • Cardiac CT appears to be equivalent to cardiac MR for the quantification of the left ventricular trabeculated layer.


Assuntos
Ventrículos do Coração , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Ventrículos do Coração/diagnóstico por imagem , Cardiomiopatias/diagnóstico por imagem , Adulto
2.
J Cardiovasc Magn Reson ; 26(1): 100995, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38219955

RESUMO

Cardiovascular magnetic resonance (CMR) is a proven imaging modality for informing diagnosis and prognosis, guiding therapeutic decisions, and risk stratifying surgical intervention. Patients with a cardiac implantable electronic device (CIED) would be expected to derive particular benefit from CMR given high prevalence of cardiomyopathy and arrhythmia. While several guidelines have been published over the last 16 years, it is important to recognize that both the CIED and CMR technologies, as well as our knowledge in MR safety, have evolved rapidly during that period. Given increasing utilization of CIED over the past decades, there is an unmet need to establish a consensus statement that integrates latest evidence concerning MR safety and CIED and CMR technologies. While experienced centers currently perform CMR in CIED patients, broad availability of CMR in this population is lacking, partially due to limited availability of resources for programming devices and appropriate monitoring, but also related to knowledge gaps regarding the risk-benefit ratio of CMR in this growing population. To address the knowledge gaps, this SCMR Expert Consensus Statement integrates consensus guidelines, primary data, and opinions from experts across disparate fields towards the shared goal of informing evidenced-based decision-making regarding the risk-benefit ratio of CMR for patients with CIEDs.


Assuntos
Consenso , Desfibriladores Implantáveis , Imageamento por Ressonância Magnética , Marca-Passo Artificial , Valor Preditivo dos Testes , Humanos , Fatores de Risco , Medição de Risco , Imageamento por Ressonância Magnética/normas , Imageamento por Ressonância Magnética/efeitos adversos , Tomada de Decisão Clínica , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/fisiopatologia , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Cardiopatias/diagnóstico por imagem , Cardiopatias/terapia
3.
J Appl Clin Med Phys ; 25(7): e14383, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38801204

RESUMO

OBJECTIVE: To assess the impact of scatter radiation on quantitative performance of first and second-generation dual-layer spectral computed tomography (DLCT) systems. METHOD: A phantom with two iodine inserts (1 and 2 mg/mL) configured to intentionally introduce high scattering conditions was scanned with a first- and second-generation DLCT. Collimation widths (maximum of 4 cm for first generation and 8 cm for second generation) and radiation dose levels were varied. To evaluate the performance of both systems, the mean CT numbers of virtual monoenergetic images (MonoEs) at different energies were calculated and compared to expected values. MonoEs at 50  versus 150 keV were plotted to assess material characterization of both DLCTs. Additionally, iodine concentrations were determined, plotted, and compared against expected values. For each experimental scenario, absolute errors were reported. RESULTS: An experimental setup, including a phantom design, was successfully implemented to simulate high scatter radiation imaging conditions. Both CT scanners illustrated high spectral accuracy for small collimation widths (1 and 2 cm). With increased collimation (4 cm), the second-generation DLCT outperformed the earlier DLCT system. Further, the spectral performance of the second-generation DLCT at an 8 cm collimation width was comparable to a 4 cm collimation on the first-generation DLCT. A comparison of the absolute errors between both systems at lower energy MonoEs illustrates that, for the same acquisition parameters, the second-generation DLCT generated results with decreased errors. Similarly, the maximum error in iodine quantification was less with second-generation DLCT (0.45  and 0.33 mg/mL for the first and second-generation DLCT, respectively). CONCLUSION: The implementation of a two-dimensional anti-scatter grid in the second-generation DLCT improves the spectral quantification performance. In the clinical routine, this improvement may enable additional clinical benefits, for example, in lung imaging.


Assuntos
Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Espalhamento de Radiação , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
4.
J Appl Clin Med Phys ; 25(4): e14300, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38386967

RESUMO

PURPOSE: The aim of this study was to characterize a second-generation wide-detector dual-layer spectral computed tomography (CT) system for material quantification accuracy, acquisition parameter and patient size dependencies, and tissue characterization capabilities. METHODS: A phantom with multiple tissue-mimicking and material-specific inserts was scanned with a dual-layer spectral detector CT using different tube voltages, collimation widths, radiation dose levels, and size configurations. Accuracy of iodine density maps and virtual monoenergetic images (MonoE) were investigated. Additionally, differences between conventional and MonoE 70 keV images were calculated to evaluate acquisition parameter and patient size dependencies. To demonstrate material quantification and differentiation, liver-mimicking inserts with adipose and iron were analyzed with a two-base decomposition utilizing MonoE 50 and 150 keV, and root mean square error (RMSE) for adipose and iron content was reported. RESULTS: Measured inserts exhibited quantitative accuracy across a wide range of MonoE levels. MonoE 70 keV images demonstrated reduced dependence compared to conventional images for phantom size (1 vs. 27 HU) and acquisition parameters, particularly tube voltage (4 vs. 37 HU). Iodine density quantification was successful with errors ranging from -0.58 to 0.44 mg/mL. Similarly, inserts with different amounts of adipose and iron were differentiated, and the small deviation in values within inserts corresponded to a RMSE of 3.49 ± 1.76% and 1.67 ± 0.84 mg/mL for adipose and iron content, respectively. CONCLUSION: The second-generation dual-layer CT enables acquisition of quantitatively accurate spectral data without compromises from differences in patient size and acquisition parameters.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Humanos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Obesidade , Ferro
5.
Eur Heart J ; 43(26): 2469-2478, 2022 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-34435642

RESUMO

AIMS: Many cardiac pacemakers and defibrillators are not approved by regulators for magnetic resonance imaging (MRI). Even following generator exchange to an approved magnetic resonance (MR)-conditional model, many systems remain classified 'non-MR conditional' due to the leads. This classification makes patient access to MRI challenging, but there is no evidence of increased clinical risk. We compared the effect of MRI on non-MR conditional and MR-conditional pacemaker and defibrillator leads. METHODS AND RESULTS: Patients undergoing clinical 1.5T MRI with pacemakers and defibrillators in three centres over 5 years were included. Magnetic resonance imaging protocols were similar for MR-conditional and non-MR conditional systems. Devices were interrogated pre- and immediately post-scan, and at follow-up, and adverse clinical events recorded. Lead parameter changes peri-scan were stratified by MR-conditional labelling. A total of 1148 MRI examinations were performed in 970 patients (54% non-MR conditional systems, 39% defibrillators, 15% pacing-dependent) with 2268 leads. There were no lead-related adverse clinical events, and no clinically significant immediate or late lead parameter changes following MRI in either MR-conditional or non-MR conditional leads. Small reductions in atrial and right ventricular sensed amplitudes and impedances were similar between groups, with no difference in the proportion of leads with parameter changes greater than pre-defined thresholds (7.1%, 95% confidence interval: 6.1-8.3). CONCLUSIONS: There was no increased risk of MRI in patients with non-MR conditional pacemaker or defibrillator leads when following recommended protocols. Standardizing MR conditions for all leads would significantly improve access to MRI by enabling patients to be scanned in non-specialist centres, with no discernible incremental risk.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Eletrônica , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Espectroscopia de Ressonância Magnética
6.
Eur Heart J ; 43(26): 2496-2507, 2022 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-35139531

RESUMO

AIMS: To evaluate the impact of a simplified, rapid cardiovascular magnetic resonance (CMR) protocol embedded in care and supported by a partner education programme on the management of cardiomyopathy (CMP) in low- and middle-income countries (LMICs). METHODS AND RESULTS: Rapid CMR focused particularly on CMP was implemented in 11 centres, 7 cities, 5 countries, and 3 continents linked to training courses for local professionals. Patients were followed up for 24 months to assess impact. The rate of subsequent adoption was tracked. Five CMR conferences were delivered (920 attendees-potential referrers, radiographers, reporting cardiologists, or radiologists) and five new centres starting CMR. Six hundred and one patients were scanned. Cardiovascular magnetic resonance indications were 24% non-contrast T2* scans [myocardial iron overload (MIO)] and 72% suspected/known cardiomyopathies (including ischaemic and viability). Ninety-eighty per cent of studies were of diagnostic quality. The average scan time was 22 ± 6 min (contrast) and 12 ± 4 min (non-contrast), a potential cost/throughput reduction of between 30 and 60%. Cardiovascular magnetic resonance findings impacted management in 62%, including a new diagnosis in 22% and MIO detected in 30% of non-contrast scans. Nine centres continued using rapid CMR 2 years later (typically 1-2 days per week, 30 min slots). CONCLUSIONS: Rapid CMR of diagnostic quality can be delivered using available technology in LMICs. When embedded in care and a training programme, costs are lower, care is improved, and services can be sustained over time.


Assuntos
Cardiomiopatias , Sobrecarga de Ferro , Cardiomiopatias/diagnóstico por imagem , Monofosfato de Citidina , Países em Desenvolvimento , Humanos , Imageamento por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética
7.
Magn Reson Med ; 87(1): 323-336, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34355815

RESUMO

PURPOSE: Magnetic susceptibility (Δχ) alterations have shown association with myocardial infarction (MI) iron deposition, yet there remains limited understanding of the relationship between relaxation rates and susceptibility or the effect of magnetic field strength. Hence, Δχ and R2∗ in MI were compared at 3T and 7T. METHODS: Subacute MI was induced by coronary artery ligation in male Yorkshire swine. 3D multiecho gradient echo imaging was performed at 1-week postinfarction at 3T and 7T. Quantitative susceptibility mapping images were reconstructed using a morphology-enabled dipole inversion. R2∗ maps and quantitative susceptibility mapping were generated to assess the relationship between R2∗ , Δχ, and field strength. Infarct histopathology was investigated. RESULTS: Magnetic susceptibility was not significantly different across field strengths (7T: 126.8 ± 41.7 ppb; 3T: 110.2 ± 21.0 ppb, P = NS), unlike R2∗ (7T: 247.0 ± 14.8 Hz; 3T: 106.1 ± 6.5 Hz, P < .001). Additionally, infarct Δχ and R2∗ were significantly higher than remote myocardium. Magnetic susceptibility at 7T versus 3T had a significant association (ß = 1.02, R2 = 0.82, P < .001), as did R2∗ (ß = 2.35, R2 = 0.98, P < .001). Infarct pathophysiology and iron deposition were detected through histology and compared with imaging findings. CONCLUSION: R2∗ showed dependence and Δχ showed independence of field strength. Histology validated the presence of iron and supported imaging findings.


Assuntos
Imageamento por Ressonância Magnética , Traumatismo por Reperfusão Miocárdica , Animais , Ferro , Fenômenos Magnéticos , Magnetismo , Masculino , Traumatismo por Reperfusão Miocárdica/diagnóstico por imagem , Suínos
8.
Eur Radiol ; 32(12): 8579-8587, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35708838

RESUMO

OBJECTIVE: Evaluation of image characteristics at ultra-low radiation dose levels of a first-generation dual-source photon-counting computed tomography (PCCT) compared to a dual-source dual-energy CT (DECT) scanner. METHODS: A multi-energy CT phantom was imaged with and without an extension ring on both scanners over a range of radiation dose levels (CTDIvol 0.4-15.0 mGy). Scans were performed in different modes of acquisition for PCCT with 120 kVp and DECT with 70/Sn150 kVp and 100/Sn150 kVp. Various tissue inserts were used to characterize the precision and repeatability of Hounsfield units (HUs) on virtual mono-energetic images between 40 and 190 keV. Image noise was additionally investigated at an ultra-low radiation dose to illustrate PCCT's ability to remove electronic background noise. RESULTS: Our results demonstrate the high precision of HU measurements for a wide range of inserts and radiation exposure levels with PCCT. We report high performance for both scanners across a wide range of radiation exposure levels, with PCCT outperforming at low exposures compared to DECT. PCCT scans at the lowest radiation exposures illustrate significant reduction in electronic background noise, with a mean percent reduction of 74% (p value ~ 10-8) compared to DECT 70/Sn150 kVp and 60% (p value ~ 10-6) compared to DECT 100/Sn150 kVp. CONCLUSIONS: This paper reports the first experiences with a clinical dual-source PCCT. PCCT provides reliable HUs without disruption from electronic background noise for a wide range of dose values. Diagnostic benefits are not only for quantification at an ultra-low dose but also for imaging of obese patients. KEY POINTS: PCCT scanners provide precise and reliable Hounsfield units at ultra-low dose levels. The influence of electronic background noise can be removed at ultra-low-dose acquisitions with PCCT. Both spectral platforms have high performance along a wide range of radiation exposure levels, with PCCT outperforming at low radiation exposures.


Assuntos
Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Doses de Radiação , Imagens de Fantasmas
9.
AJR Am J Roentgenol ; 218(5): 831-832, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34910536

RESUMO

Although professional societies now support MRI in patients with nonconditional (legacy) cardiac implanted electronic devices (CIEDs), concern remains regarding potential cumulative effects of serial examinations. We evaluated 481 patients with CIEDs who underwent 599 1.5-T MRI examinations (44.6% cardiac examinations), including 68 patients who underwent multiple examinations (maximum, seven examinations). No major events occurred. The minor adverse event rate was 5.7%. Multiple statistical evaluations showed no increase in adverse event rate with increasing number of previous examinations.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Eletrônica , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Exame Físico
10.
Am J Kidney Dis ; 77(4): 517-528, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32861792

RESUMO

Gadolinium-based contrast agents (GBCAs) improve the diagnostic capabilities of magnetic resonance imaging. Although initially believed to be without major adverse effects, GBCA use in patients with severe chronic kidney disease (CKD) was demonstrated to cause nephrogenic systemic fibrosis (NSF). Restrictive policies of GBCA use in CKD and selective use of GBCAs that bind free gadolinium more strongly have resulted in the virtual elimination of NSF cases. Contemporary studies of the use of GBCAs with high binding affinity for free gadolinium in severe CKD demonstrate an absence of NSF. Despite these observations and the limitations of contemporary studies, physicians remain concerned about GBCA use in severe CKD. Concerns of GBCA use in severe CKD are magnified by recent observations demonstrating gadolinium deposition in brain and a possible systemic syndrome attributed to GBCAs. Radiologic advances have resulted in several new imaging modalities that can be used in the severe CKD population and that do not require GBCA administration. In this article, we critically review GBCA use in patients with severe CKD and provide recommendations regarding GBCA use in this population.


Assuntos
Meios de Contraste/efeitos adversos , Gadolínio/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Insuficiência Renal Crônica/diagnóstico por imagem , Encéfalo/efeitos dos fármacos , Encéfalo/metabolismo , Ensaios Clínicos como Assunto/métodos , Meios de Contraste/metabolismo , Gadolínio/metabolismo , Taxa de Filtração Glomerular/efeitos dos fármacos , Taxa de Filtração Glomerular/fisiologia , Humanos , Imageamento por Ressonância Magnética/normas , Dermopatia Fibrosante Nefrogênica/diagnóstico por imagem , Dermopatia Fibrosante Nefrogênica/metabolismo , Insuficiência Renal Crônica/metabolismo , Fatores de Risco
11.
J Cardiovasc Magn Reson ; 23(1): 120, 2021 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-34689798

RESUMO

BACKGROUND: Hypertrophic cardiomyopathy (HCM) is characterized by increased left ventricular wall thickness, cardiomyocyte hypertrophy, and fibrosis. Adverse cardiac risk characterization has been performed using late gadolinium enhancement (LGE), native T1, and extracellular volume (ECV). Relaxation time constants are affected by background field inhomogeneity. T1ρ utilizes a spin-lock pulse to decrease the effect of unwanted relaxation. The objective of this study was to study T1ρ as compared to T1, ECV, and LGE in HCM patients. METHODS: HCM patients were recruited as part of the Novel Markers of Prognosis in Hypertrophic Cardiomyopathy study, and healthy controls were matched for comparison. In addition to cardiac functional imaging, subjects underwent T1 and T1ρ cardiovascular magnetic resonance imaging at short-axis positions at 1.5T. Subjects received gadolinium and underwent LGE imaging 15-20 min after injection covering the entire heart. Corresponding basal and mid short axis LGE slices were selected for comparison with T1 and T1ρ. Full-width half-maximum thresholding was used to determine the percent enhancement area in each LGE-positive slice by LGE, T1, and T1ρ. Two clinicians independently reviewed LGE images for presence or absence of enhancement. If in agreement, the image was labeled positive (LGE + +) or negative (LGE --); otherwise, the image was labeled equivocal (LGE + -). RESULTS: In 40 HCM patients and 10 controls, T1 percent enhancement area (Spearman's rho = 0.61, p < 1e-5) and T1ρ percent enhancement area (Spearman's rho = 0.48, p < 0.001e-3) correlated with LGE percent enhancement area. T1 and T1ρ percent enhancement areas were also correlated (Spearman's rho = 0.28, p = 0.047). For both T1 and T1ρ, HCM patients demonstrated significantly longer relaxation times compared to controls in each LGE category (p < 0.001 for all). HCM patients also showed significantly higher ECV compared to controls in each LGE category (p < 0.01 for all), and LGE -- slices had lower ECV than LGE + + (p = 0.01). CONCLUSIONS: Hyperenhancement areas as measured by T1ρ and LGE are moderately correlated. T1, T1ρ, and ECV were elevated in HCM patients compared to controls, irrespective of the presence of LGE. These findings warrant additional studies to investigate the prognostic utility of T1ρ imaging in the evaluation of HCM patients.


Assuntos
Cardiomiopatia Hipertrófica , Meios de Contraste , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/patologia , Fibrose , Gadolínio , Humanos , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Miocárdio/patologia , Valor Preditivo dos Testes
12.
Am J Kidney Dis ; 75(1): 105-113, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31473019

RESUMO

Contrast-induced nephropathy (CIN) has long been observed in both experimental and clinical studies. However, recent observational studies have questioned the prevalence and severity of CIN following intravenous contrast exposure. Initial studies of acute kidney injury following intravenous contrast were limited by the absence of control groups or contained control groups that did not adjust for additional acute kidney injury risk factors, including prevalent chronic kidney disease, as well as accepted prophylactic strategies. More contemporary use of propensity score-adjusted models have attempted to minimize the risk for selection bias, although bias cannot be completely eliminated without a prospective randomized trial. Based on existing data, we recommend the following CIN risk classification: patients with estimated glomerular filtration rates (eGFRs) ≥ 45mL/min/1.73m2 are at negligible risk for CIN, while patients with eGFRs<30mL/min/1.73m2 are at high risk for CIN. Patients with eGFRs between 30 and 44mL/min/1.73m2 are at an intermediate risk for CIN unless diabetes mellitus is present, which would further increase the risk. In all patients at any increased risk for CIN, the risk for CIN needs to be balanced by the risk of not performing an intravenous contrast-enhanced study.


Assuntos
Injúria Renal Aguda/induzido quimicamente , Meios de Contraste/administração & dosagem , Injúria Renal Aguda/epidemiologia , Administração Intravenosa/estatística & dados numéricos , Meios de Contraste/efeitos adversos , Hidratação , Humanos , Injeções Intra-Arteriais/estatística & dados numéricos , Mortalidade , Diálise Renal , Insuficiência Renal Crônica/epidemiologia , Tomografia Computadorizada por Raios X
13.
J Magn Reson Imaging ; 51(3): 657-674, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31566852

RESUMO

The use of magnetic resonance imaging (MRI) is increasing globally, and MRI safety issues regarding medical devices, which are constantly being developed or upgraded, represent an ongoing challenge for MRI personnel. To assist the MRI community, a panel of 10 radiologists with expertise in MRI safety from nine high-volume academic centers formed, with the objective of providing clarity on some of the MRI safety issues for the 10 most frequently questioned devices. Ten device categories were identified. The panel reviewed the literature, including key MRI safety issues regarding screening and adverse event reports, in addition to the manufacturer's Instructions For Use. Using a Delphi-inspired method, 36 practical recommendations were generated with 100% consensus that can aid the clinical MRI community. Level of Evidence: 5 Technical Efficacy Stage: 5 J. Magn. Reson. Imaging 2020;51:657-674.


Assuntos
Imageamento por Ressonância Magnética , Consenso , Imageamento por Ressonância Magnética/efeitos adversos
15.
J Cardiovasc Magn Reson ; 21(1): 5, 2019 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-30626437

RESUMO

BACKGROUND: Endogenous contrast T1ρ cardiovascular magnetic resonance (CMR) can detect scar or infiltrative fibrosis in patients with ischemic or non-ischemic cardiomyopathy. Existing 2D T1ρ techniques have limited spatial coverage or require multiple breath-holds. The purpose of this project was to develop an accelerated, free-breathing 3D T1ρ mapping sequence with whole left ventricle coverage using a multicoil, compressed sensing (CS) reconstruction technique for rapid reconstruction of undersampled k-space data. METHODS: We developed a cardiac- and respiratory-gated, free-breathing 3D T1ρ sequence and acquired data using a variable-density k-space sampling pattern (A = 3). The effect of the transient magnetization trajectory, incomplete recovery of magnetization between T1ρ-preparations (heart rate dependence), and k-space sampling pattern on T1ρ relaxation time error and edge blurring was analyzed using Bloch simulations for normal and chronically infarcted myocardium. Sequence accuracy and repeatability was evaluated using MnCl2 phantoms with different T1ρ relaxation times and compared to 2D measurements. We further assessed accuracy and repeatability in healthy subjects and compared these results to 2D breath-held measurements. RESULTS: The error in T1ρ due to incomplete recovery of magnetization between T1ρ-preparations was T1ρhealthy = 6.1% and T1ρinfarct = 10.8% at 60 bpm and T1ρhealthy = 13.2% and T1ρinfarct = 19.6% at 90 bpm. At a heart rate of 60 bpm, error from the combined effects of readout-dependent magnetization transients, k-space undersampling and reordering was T1ρhealthy = 12.6% and T1ρinfarct = 5.8%. CS reconstructions had improved edge sharpness (blur metric = 0.15) compared to inverse Fourier transform reconstructions (blur metric = 0.48). There was strong agreement between the mean T1ρ estimated from the 2D and accelerated 3D data (R2 = 0.99; P < 0.05) acquired on the MnCl2 phantoms. The mean R1ρ estimated from the accelerated 3D sequence was highly correlated with MnCl2 concentration (R2 = 0.99; P < 0.05). 3D T1ρ acquisitions were successful in all human subjects. There was no significant bias between undersampled 3D T1ρ and breath-held 2D T1ρ (mean bias = 0.87) and the measurements had good repeatability (COV2D = 6.4% and COV3D = 7.1%). CONCLUSIONS: This is the first report of an accelerated, free-breathing 3D T1ρ mapping of the left ventricle. This technique may improve non-contrast myocardial tissue characterization in patients with heart disease in a scan time appropriate for patients.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Análise de Fourier , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico por imagem , Técnicas de Imagem de Sincronização Respiratória , Técnicas de Imagem de Sincronização Cardíaca/instrumentação , Estudos de Casos e Controles , Eletrocardiografia , Estudos de Viabilidade , Frequência Cardíaca , Humanos , Imageamento por Ressonância Magnética/instrumentação , Modelos Cardiovasculares , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Miocárdio/patologia , Imagens de Fantasmas , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Respiração , Técnicas de Imagem de Sincronização Respiratória/instrumentação
16.
J Biomech Eng ; 141(3)2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30516240

RESUMO

The efficacy of reduced order modeling for transstenotic pressure drop in the coronary arteries is presented. Coronary artery disease is a leading cause of death worldwide and the computation of pressure drop in the coronary arteries has become a standard for evaluating the functional significance of a coronary stenosis. Comprehensive models typically employ three-dimensional (3D) computational fluid dynamics (CFD) to simulate coronary blood flow in order to compute transstenotic pressure drop at the arterial stenosis. In this study, we evaluate the capability of different hydrodynamic models to compute transstenotic pressure drop. Models range from algebraic formulae to one-dimensional (1D), two-dimensional (2D), and 3D time-dependent CFD simulations. Although several algebraic pressure-drop formulae have been proposed in the literature, these models were found to exhibit wide variation in predictions. Nonetheless, we demonstrate an algebraic formula that provides consistent predictions with 3D CFD results for various changes in stenosis severity, morphology, location, and flow rate. The accounting of viscous dissipation and flow separation were found to be significant contributions to accurate reduce order modeling of transstenotic coronary hemodynamics.

17.
Catheter Cardiovasc Interv ; 92(3): 601-606, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-28417602

RESUMO

Left ventricular outflow tract (LVOT) obstruction is a recognized complication of transcatheter mitral valve-in-valve replacement in previous surgical prostheses. We describe a patient who was high risk for repeat open surgery in whom the LVOT was compromised by a surgical strut and the potential for LVOT obstruction. A novel approach to avoiding this complication was utilized. A perfusion balloon was inflated in the outflow tract to provide an opposing force during mitral valve deployment resulting in less flaring of the strut into the outflow tract thereby improving the neo-LVOT area. No outflow tract obstruction occurred. The advantages of this approach as well as other alternative solutions to this problem are discussed. © 2017 Wiley Periodicals, Inc.


Assuntos
Valvuloplastia com Balão/métodos , Bioprótese , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Estenose da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Obstrução do Fluxo Ventricular Externo/prevenção & controle , Idoso de 80 Anos ou mais , Valvuloplastia com Balão/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Angiografia por Tomografia Computadorizada , Ecocardiografia Doppler , Ecocardiografia Tridimensional , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/fisiopatologia , Desenho de Prótese , Recuperação de Função Fisiológica , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/fisiopatologia
18.
Eur Radiol ; 28(2): 851-860, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28875364

RESUMO

OBJECTIVES: To determine resource utilisation according to age and gender-specific subgroups in two large randomized diagnostic trials. METHODS: We pooled patient-specific data from ACRIN-PA 4005 and ROMICAT II that enrolled subjects with acute chest pain at 14 US sites. Subjects were randomized between a standard work-up and a pathway utilizing cardiac computed tomography angiography (CCTA) and followed for the occurrence of acute coronary syndrome (ACS) and resource utilisation during index hospitalisation and 1-month follow-up. Study endpoints included diagnostic accuracy of CCTA for the detection of ACS as well as resource utilisation. RESULTS: Among 1240 patients who underwent CCTA, negative predictive value of CCTA to rule out ACS remained very high (≥99.4%). The proportion of patients undergoing additional diagnostic testing and cost increased with age for both sexes (p < 0.001), and was higher in men as compared to women older than 60 years (43.1% vs. 23.4% and $4559 ± 3382 vs. $3179 ± 2562, p < 0.01; respectively). Cost to rule out ACS was higher in men (p < 0.001) and significantly higher for patients older than 60 years ($2860-5935 in men, p < 0.001). CONCLUSIONS: CCTA strategy in patients with acute chest pain results in varying resource utilisation according to age and gender-specific subgroups, mandating improved selection for advanced imaging. KEY POINTS: • In this analysis, CAD and ACS increased with age and male gender. • CCTA in patients with acute chest pain results in varying resource utilisation. • Significant increase of diagnostic testing and cost with age for both sexes. • Cost to rule out ACS is higher in men and patients >60 years. • Improved selection of subjects for cardiac CTA result in more resource-driven implementation.


Assuntos
Síndrome Coronariana Aguda/diagnóstico por imagem , Dor no Peito/etiologia , Angiografia por Tomografia Computadorizada/economia , Angiografia por Tomografia Computadorizada/estatística & dados numéricos , Angiografia Coronária/economia , Angiografia Coronária/estatística & dados numéricos , Fatores Etários , Feminino , Custos de Cuidados de Saúde , Hospitalização/economia , Humanos , Masculino , Pessoa de Meia-Idade , Fatores Sexuais
19.
Curr Cardiol Rep ; 20(4): 24, 2018 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-29520449

RESUMO

PURPOSE OF REVIEW: To compare outcomes between registries and randomized controlled trials of coronary computed tomographic angiography (CCTA)-based versus standard of care approaches to the initial evaluation of patients with acute chest pain. RECENT FINDINGS: Randomized trials have demonstrated CCTA to be a safe and efficient tool for triage of low- to intermediate-risk patients presenting to the emergency department with chest pain. Recent studies demonstrate heterogeneous result using different standard of care approaches for evaluation of hard endpoints in comparison with standard evaluation. Also, there has been continued concern for increase in subsequent testing after coronary CTA. Although CCTA improves detection of coronary artery disease, it is uncertain if it will bring improvement of long-term health outcomes at this point of time. Careful analysis of the previous results and further investigation will be required to validate evaluation of hard endpoints.


Assuntos
Dor no Peito/diagnóstico por imagem , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Serviço Hospitalar de Emergência/normas , Tomografia Computadorizada por Raios X , Dor no Peito/etiologia , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Sistema de Registros , Triagem/métodos
20.
Magn Reson Med ; 78(2): 678-688, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-27579717

RESUMO

PURPOSE: Develop self-gated MRI for distinct heartbeat morphologies in subjects with arrhythmias. METHODS: Golden angle radial data was obtained in seven sinus and eight arrhythmias subjects. An image-based cardiac navigator was derived from single-shot images, distinct beat types were identified, and images were reconstructed for repeated morphologies. Image sharpness, contrast, and volume variation were quantified and compared with self-gated MRI. Images were scored for image quality and artifacts. Hemodynamic parameters were computed for each distinct beat morphology in bigeminy and trigeminy subjects and for sinus beats in patients with infrequent premature ventricular contractions. RESULTS: Images of distinct beat types were reconstructed except for two patients with infrequent premature ventricular contractions. Image contrast and sharpness were similar to sinus self-gated images (contrast = 0.45 ± 0.13 and 0.43 ± 0.15; sharpness = 0.21 ± 0.11 and 0.20 ± 0.05). Visual scoring was highest in self-gated images (4.1 ± 0.3) compared with real-time (3.9 ± 0.4) and ECG-gated cine (3.4 ± 1.5). ECG-gated cine had less artifacts than self-gating (2.3 ± 0.7 and 2.1 ± 0.2), but was affected by misgating in two subjects. Among arrhythmia subjects, post-extrasystole/sinus (58.1 ± 8.6 mL) and interrupted sinus (61.4 ± 5.9 mL) stroke volume was higher than extrasystole (32.0 ± 16.5 mL; P < 0.02). CONCLUSION: Self-gated imaging can reconstruct images during ectopy and allowed for quantification of hemodynamic function of different beat morphologies. Magn Reson Med 78:678-688, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Arritmias Cardíacas/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Adulto , Idoso , Algoritmos , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA