RESUMO
BACKGROUND: Intracranial pressure (ICP) monitoring in children currently requires invasive techniques. Subharmonic aided pressure estimation (SHAPE) uses contrast-enhanced ultrasound (CEUS) to measure intravascular and interstitial pressure, but utility in ICP measurements has yet to be explored. OBJECTIVE: The objective of this study was to investigate SHAPE as a novel tool for noninvasive ICP measurements in fetal lambs. MATERIALS AND METHODS: Eighteen fetal lambs at 107-139 days gestational age (term = 145 days) underwent subdural ICP catheter placement. The brain was imaged in the coronal plane in CEUS mode optimized for SHAPE, while infusing an US contrast agent into the fetal circulation. After SHAPE calibration, saline was infused via the subdural catheter to increase ICP. Five-second SHAPE cine clips were obtained at various ICPs. Subharmonic intensity values of the whole brain and thalami were correlated with ICP values using mixed effects linear regression analyses and the strength of the relationship was evaluated by Spearman's rank-order correlation. RESULTS: Forty-nine experiments produced 723 datapoints, including SHAPE intensity values and mean ICP measurements. There was a statistically significant inverse relationship between SHAPE intensity values and ICP measurements in the whole brain and thalami (median rho value - 0.58 and - 0.56, respectively). CONCLUSION: SHAPE intensity values of the brain demonstrate an inverse and statistically significant correlation with in vivo ICP measurements in an animal model.
Assuntos
Meios de Contraste , Pressão Intracraniana , Animais , Ovinos , Humanos , Ultrassonografia/métodos , Encéfalo/diagnóstico por imagemRESUMO
OBJECTIVE: Breast cancer is the most frequent type of cancer among women. This multi-center study assessed the ability of 3D contrast-enhanced ultrasound to characterize suspicious breast lesions using clinical assessments and quantitative parameters. METHODS: Women with suspicious breast lesions scheduled for biopsy were enrolled in this prospective, study. Following 2D grayscale ultrasound and power Doppler imaging (PDI), a contrast agent (Definity; Lantheus) was administrated. Contrast-enhanced 3D harmonic imaging (HI; transmitting/receiving at 5.0/10.0 MHz), as well as 3D subharmonic imaging (SHI; transmitting/receiving at 5.8/2.9 MHz), were performed using a modified Logiq 9 scanner (GE Healthcare). Five radiologists independently scored the imaging modes (including standard-of-care imaging) using a 7-point BIRADS scale as well as lesion vascularity and diagnostic confidence. Parametric volumes were constructed from time-intensity curves for vascular heterogeneity, perfusion, and area under the curve. Diagnostic accuracy was determined relative to pathology using receiver operating characteristic (ROC) and reverse, step-wise logistical regression analyses. The κ-statistic was calculated for inter-reader agreement. RESULTS: Data were successfully acquired in 219 cases and biopsies indicated 164 (75%) benign and 55 (25%) malignant lesions. SHI depicted more anastomoses and vascularity than HI (P < .021), but there were no differences by pathology (P > .27). Ultrasound achieved accuracies of 82 to 85%, which was significantly better than standard-of-care imaging (72%; P < .03). SHI increased diagnostic confidence by 3 to 6% (P < .05), but inter-reader agreements were medium to low (κ < 0.52). The best regression model achieved 97% accuracy by combining clinical reads and parametric SHI. CONCLUSIONS: Combining quantitative 3D SHI parameters and clinical assessments improves the characterization of suspicious breast lesions.
Assuntos
Neoplasias da Mama , Meios de Contraste , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Imageamento Tridimensional/métodos , Estudos Prospectivos , Ultrassonografia/métodos , Ultrassonografia Doppler/métodosRESUMO
OBJECTIVES: Hepatic venous pressure gradient (HVPG) is considered the standard in quantifying portal hypertension, but can be unreliable in dialysis patients. A noninvasive ultrasound technique, subharmonic-aided pressure estimation (SHAPE), may be a valuable surrogate of these pressure estimates. This study compared SHAPE and HVPG with pathology findings for fibrosis in dialysis patients. METHODS: This was a subgroup study from an IRB-approved trial that included 20 patients on dialysis undergoing SHAPE examinations of portal and hepatic veins using a modified Logiq 9 scanner (GE, Waukesha, WI), during infusion of Sonazoid (GE Healthcare, Oslo, Norway). SHAPE was compared to HVPG and pathology findings using the Ludwig-Batts scoring system for fibrosis. Logistic regression, ROC analysis, and t-tests were used to compare HVPG and SHAPE with pathological findings of fibrosis. RESULTS: Of 20 cases, 5 had HVPG values corresponding to subclinical and clinical portal hypertension (≥6 and ≥10 mmHg, respectively) while 15 had normal HVPG values (≤5 mmHg). SHAPE and HVPG correlated moderately (r = 0.45; P = .047). SHAPE showed a trend toward correlating with fibrosis (r = 0.42; P = .068), while HVPG did not (r = 0.18; P = .45). SHAPE could differentiate between mild (stage 0-1) and moderate to severe (stage 2-4) fibrosis (-10.4 ± 4.9 dB versus -5.4 ± 3.2 dB; P = .035), HVPG could not (3.0 ± 0.6 mmHg versus 4.8 ± 0.7 mmHg; P = .30). ROC curves showed a diagnostic accuracy for SHAPE of 80%, while HVPG reached 76%. CONCLUSION: Liver fibrosis staging in dialysis patients evaluated for portal hypertension appears to be more accurately predicted by SHAPE than by HVPG; albeit in a small sample size.
Assuntos
Hipertensão Portal , Insuficiência Renal Crônica , Humanos , Hipertensão Portal/complicações , Hipertensão Portal/diagnóstico por imagem , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico por imagem , Pressão na Veia Porta , Diálise Renal , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico por imagem , Insuficiência Renal Crônica/terapiaRESUMO
BACKGROUND: Portal hypertension is the underlying cause of most complications associated with cirrhosis, with the hepatic venous pressure gradient (HVPG) used for diagnosis and disease progression. Subharmonic imaging (SHI) is a contrast-specific imaging technique receiving at half the transmit frequency resulting in better tissue suppression. AIMS: To determine whether the presence of optimized SHI signals inside the hepatic vein can be used as a screening test for portal hypertension. METHODS: This prospective trial had 131 patients undergoing SHI examination of portal and hepatic veins using a modified Logiq 9 scanner (GE, Waukesha, WI). Images acquired after infusion of the ultrasound contrast agent Sonazoid (GE Healthcare, Oslo, Norway) were assessed for the presence of optimized SHI signals in the hepatic vein and compared to the HVPG values obtained as standard of care. RESULTS: Of 131 cases, 64 had increased HVPG values corresponding to subclinical (n = 31) and clinical (n = 33) portal hypertension (> 5 and > 10 mmHg, respectively), and 67 had normal HVPG values (< 5 mmHg). Two readers performed independent, binary qualitative assessments of the acquired digital clips. Reader one (experienced radiologist) achieved for the subclinical subgroup sensitivity of 98%, specificity of 88%, and ROC area of 0.93 and for the clinical subgroup sensitivity of 100% and specificity of 61%, with an ROC area of 0.74. Reader two (less experienced radiologist) achieved for the subclinical subgroup sensitivity of 77%, specificity of 76%, and ROC area of 0.76 and for the clinical subgroup sensitivity of 88% and specificity of 63%, with an ROC area of 0.70. Readers agreement was of 83% with kappa value of 0.66. CONCLUSION: The presence of optimized SHI signals inside the hepatic vein can be a qualitative screening test for portal hypertension, which could reduce the need for invasive diagnostic procedures.
Assuntos
Veias Hepáticas/diagnóstico por imagem , Hipertensão Portal/diagnóstico por imagem , Ultrassonografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Compostos Férricos , Humanos , Ferro , Masculino , Pessoa de Meia-Idade , Óxidos , Estudos Prospectivos , Adulto JovemRESUMO
The ability to provide prompt, real-time, easily accessible and radiation-free diagnostic assessments makes ultrasound (US) one of the most versatile imaging modalities. The introduction and development of stable microbubble-based ultrasound contrast agents (UCAs) in the early 1990s improved visualization of complex vascular structures, overcoming some of the limitations of B-mode and Doppler imaging. UCAs have been used extensively in the adult population to visualize vasculature and to evaluate perfusion and blood flow dynamics in organs and lesions. Since the first observations that air bubbles within a liquid can generate a strong echogenic effect, to the early makeshift approaches with agitated saline, and later to the development of industrially produced and federally approved UCAs, these agents have evolved to become both clinically and commercially viable. Perhaps the most exciting potential of UCAs is being uncovered by current research that explores the use of these agents for molecular imaging and therapeutic applications. As contrast-enhanced ultrasound (CEUS) becomes more widely available, it is important for pediatric radiologists to understand the physics of the interaction between the US signal and the microbubbles in order to properly utilize them for the highest level of diagnostic imaging and interventions. In this article we introduce the composition of UCAs and the physics of their behavior in US, and we offer a brief history of their development over the last decades.
Assuntos
Meios de Contraste , Microbolhas , Adulto , Criança , Humanos , Radiologistas , UltrassonografiaRESUMO
OBJECTIVES: This pilot study evaluated whether contrast-enhanced subharmonic imaging (SHI) could be used to characterize adnexal masses before surgical intervention. METHODS: Ten women (with 12 lesions) scheduled for surgery of an ovarian mass underwent an SHI examination of their adnexal region using a modified LOGIQ E9 scanner (GE Healthcare, Waukesha, WI) with an endocavitary transducer, in which digital clips were acquired by pulse destruction-replenishment SHI across the lesions. Time-intensity curves were created offline to quantitatively evaluate SHI parameters (fractional tumor perfusion, peak contrast intensity, time to peak contrast enhancement, and area under the time-intensity curve), which were compared to pathologic characterizations of the lesions. RESULTS: Of the 12 masses, 8 were benign, and 4 were malignant. A qualitative analysis of the SHI images by an experienced radiologist resulted in diagnostic accuracy of 70%, compared to 56% without contrast, whereas an inexperienced radiologist improved from 50% to 58% accuracy, demonstrating the benefit of SHI. A quantitative analysis of SHI parameters produced diagnostic accuracy as high as 81%. Peak contrast intensity was significantly greater in malignant than benign masses (mean ± SD, 0.109 ± 0.088 versus 0.046 ± 0.030 arbitrary units; P = .046). Malignant masses also showed significantly greater perfusion than benign masses (24.79% ± 25.34% versus 7.62% ± 6.50%; P = .045). When the radiologist reads were combined with the most predictive quantitative SHI parameter (percent perfusion), diagnostic accuracy improved to 84% for the experienced radiologist and 96% for the novice radiologist. CONCLUSIONS: Results indicate that SHI for presurgical characterization of adnexal masses may improve the determination of malignancy and diagnostic accuracy, albeit based on a small sample size.
Assuntos
Doenças dos Anexos/diagnóstico por imagem , Meios de Contraste , Aumento da Imagem/métodos , Neoplasias Ovarianas/diagnóstico por imagem , Ultrassonografia/métodos , Anexos Uterinos/diagnóstico por imagem , Adulto , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos TestesRESUMO
OBJECTIVES: To investigate 3-dimensional subharmonic aided pressure estimation (SHAPE) for measuring intraplaque pressure and the pressure gradient across the plaque cap as novel biomarkers for potentially predicting plaque vulnerability. METHODS: Twenty-seven rabbits received a high-cholesterol diet for 2 weeks before a balloon catheter injury to denude the endothelium of the aorta, followed by 8 to 10 weeks of the high-cholesterol diet to create arteriosclerotic plaques. SHAPE imagings of the resulting plaques were performed 12, 16, and 20 weeks after injury using a LOGIQ 9 scanner with a 4D10L probe (GE Healthcare, Milwaukee, WI) before and during an infusion of Definity (Lantheus Medical Imaging, North Billerica, MA) and Sonazoid (GE Healthcare, Oslo, Norway). The ratios of the maximum subharmonic magnitudes at baseline and during the infusion were correlated with the intraplaque pressure and pressure gradient across the plaque cap obtained from direct measurements. RESULTS: Ten rabbits died prematurely after the balloon injury procedure or due to toxicity from the high-cholesterol diet, whereas 2 rabbits were excluded for other conditions. Five rabbits were scanned in the 12-, 16-, and 20-week groups, respectively. Even after 20 weeks, the plaques that developed were very small (mean ± SD, 0.9 ± 0.4 × 0.14 ± 0.05 cm). Definity performed better than Sonazoid in this application but still only achieved a moderate correlation with pressure across the plaque cap (Definity, r = -0.40; Sonazoid, r = 0.22) and intraplaque pressure (Definity, r = -0.19; Sonazoid, r = -0.11). CONCLUSIONS: Initial findings from plaque pressure estimation using 3-dimensional SHAPE technique showed only moderate correlations with reference standards, but that may be have been due to weaknesses in the animal model studied.
Assuntos
Pressão Sanguínea , Imageamento Tridimensional , Placa Aterosclerótica/diagnóstico por imagem , Ultrassonografia/métodos , Animais , Meios de Contraste/administração & dosagem , Compostos Férricos/administração & dosagem , Fluorocarbonos/administração & dosagem , Aumento da Imagem/métodos , Ferro/administração & dosagem , Óxidos/administração & dosagem , CoelhosRESUMO
Subharmonic-aided pressure estimation (SHAPE) estimates hydrostatic pressure using the inverse relationship with subharmonic amplitude variations of ultrasound contrast agents (UCAs). We studied the impact of varying incident acoustic outputs (IAO), UCA concentration, and hematocrit on SHAPE. A Logiq 9 scanner with a 4C curvilinear probe (GE, Milwaukee, Wisconsin) was used with Sonazoid (GE Healthcare, Oslo, Norway) transmitting at 2.5 MHz and receiving at 1.25 MHz. An improved IAO selection algorithm provided improved correlations ( r from -0.85 to -0.95 vs. -0.39 to -0.98). There was no significant change in SHAPE gradient as the pressure increased from 10 to 40 mmHg and hematocrit concentration was tripled from 1.8 to 4.5 mL/L (Δ0.00-0.01 dB, p = 0.18), and as UCA concentration was increased from 0.2 to 1.2 mL/L (Δ0.02-0.05 dB, p = 0.75). The results for the correlation between the SHAPE gradient and hematocrit values for patients ( N = 100) in an ongoing clinical trial were also calculated showing a poor correlation value of 0.14. Overall, the SHAPE gradient is independent of hematocrit and UCA concentration. An improved algorithm for IAO selection will make SHAPE more accurate.
Assuntos
Meios de Contraste , Aumento da Imagem/métodos , Ultrassonografia/métodos , Algoritmos , Humanos , Técnicas In Vitro , Reprodutibilidade dos Testes , Estudos RetrospectivosRESUMO
OBJECTIVES: To use subharmonic imaging (SHI) to depict the vascularity of pancreatic masses compared to contrast-enhanced endoscopic ultrasound (EUS) and pathologic results. METHODS: Sixteen patients scheduled for biopsy of a pancreatic mass were enrolled in an Institutional Review Board-approved study. Pulse-inversion SHI (transmitting/receiving at 2.5/1.25 MHz) was performed on a LOGIQ 9 system (GE Healthcare, Milwaukee, WI) with a 4C transducer, whereas contrast harmonic EUS (transmitting/receiving at 4.7/9.4 MHz) was performed with a radial endoscope (GF-UTC180; Olympus Corporation, Tokyo, Japan) connected to a ProSound SSD α-10 scanner (Hitachi Aloka, Tokyo, Japan). Two injections of the contrast agent Definity (Lantheus Medical Imaging, North Billerica, MA) were administrated (0.3-0.4 and 0.6-0.8 mL for EUS and SHI, respectively). Contrast-to-tissue ratios (CTRs) in the mass and an adjacent vessel were calculated. Four physicians independently scored the images (benign to malignant) for diagnostic accuracy and inter-reader agreement. RESULTS: One patient dropped out before imaging, leaving 11 adenocarcinomas, 1 gastrointestinal stromal tumor with pancreatic infiltration, and 3 benign masses. Marked subharmonic signals were obtained in all patients, with intratumoral blood flow clearly visualized with SHI. Significantly greater CTRs were obtained in the masses with SHI than with EUS (mean ± SD, 1.71 ± 1.63 versus 0.63 ± 0.89; P = .016). There were no differences in the CTR in the surrounding vessels or when grouped by pathologic results (P > .60). The accuracies for contrast EUS and SHI were low (<53%), albeit with a greater κ value for SHI (0.34) than for EUS (0.13). CONCLUSIONS: Diagnostic accuracy of contrast EUS and transabdominal SHI for assessment of pancreatic masses was quite low in this pilot study. However, SHI had improved tumoral CTRs relative to contrast EUS.
Assuntos
Meios de Contraste , Endossonografia/métodos , Aumento da Imagem/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pâncreas/diagnóstico por imagem , Projetos Piloto , Reprodutibilidade dos TestesRESUMO
OBJECTIVES: Subharmonic imaging (SHI) is a technique that uses the nonlinear oscillations of microbubbles when exposed to ultrasound at high pressures transmitting at the fundamental frequency ie, fo and receiving at half the transmit frequency (ie, fo /2). Subharmonic aided pressure estimation (SHAPE) is based on the inverse relationship between the subharmonic amplitude of the microbubbles and the ambient pressure change. METHODS: Eight waveforms with different envelopes were optimized with respect to acoustic power at which the SHAPE study is most sensitive. The study was run with four input transmit cycles, first in vitro and then in vivo in three canines to select the waveform that achieved the best sensitivity for detecting changes in portal pressures using SHAPE. A Logiq 9 scanner with a 4C curvi-linear array was used to acquire 2.5 MHz radio-frequency data. Scanning was performed in dual imaging mode with B-mode imaging at 4 MHz and a SHI contrast mode transmitting at 2.5 MHz and receiving at 1.25 MHz. Sonazoid, which is a lipid stabilized gas filled bubble of perfluorobutane, was used as the contrast agent in this study. RESULTS: A linear decrease in subharmonic amplitude with increased pressure was observed for all waveforms (r from -0.77 to -0.93; P < .001) in vitro. There was a significantly higher correlation of the SHAPE gradient with changing pressures for the broadband pulses as compared to the narrowband pulses in both in vitro and in vivo results. The highest correlation was achieved with a Gaussian windowed binomial filtered square wave with an r-value of -0.95. One of the three canines was eliminated for technical reasons, while the other two produced very similar results to those obtained in vitro (r from -0.72 to -0.98; P <.01). The most consistent in vivo results were achieved with the Gaussian windowed binomial filtered square wave (r = -0.95 and -0.96). CONCLUSIONS: Using this waveform is an improvement to the existing SHAPE technique (where a square wave was used) and should make SHAPE more sensitive for noninvasively determining portal hypertension.
Assuntos
Pressão na Veia Porta/fisiologia , Veia Porta/diagnóstico por imagem , Veia Porta/fisiologia , Ultrassonografia/métodos , Animais , Meios de Contraste , Cães , Compostos Férricos , Aumento da Imagem/métodos , Ferro , Microbolhas , Óxidos , Imagens de Fantasmas , Reprodutibilidade dos TestesRESUMO
OBJECTIVE: Breast cancer is the most frequent type of cancer among women (25% of all cancers). The angiogenic process that fuels the growth of tumors is a potential early indicator for differentiating between malignant and benign tumors. Recently, the use of microbubble-based contrast agents combined with ultrasound has allowed the development of contrast agent-specific imaging modes that provide visualization of tumor neovascularity. CONCLUSION: Contrast-enhanced Doppler, harmonic, and subharmonic imaging are some of the imaging modes that have been investigated for visualizing and quantifying the vascularity in breast tumors.
Assuntos
Neoplasias da Mama/diagnóstico por imagem , Ultrassonografia Mamária/métodos , Neoplasias da Mama/patologia , Meios de Contraste , Feminino , Humanos , MicrobolhasRESUMO
OBJECTIVES: Different methods for obtaining tumor neovascularity parameters based on immunohistochemical markers were compared to contrast-enhanced subharmonic imaging (SHI). METHODS: Eighty-five athymic nude female rats were implanted with 5 × 10(6) breast cancer cells (MDA-MB-231) in the mammary fat pad. The contrast agent Definity (Lantheus Medical Imaging, North Billerica, MA) was injected, and SHI was performed using a modified Sonix RP scanner (Analogic Ultrasound, Richmond, British Columbia, Canada) with a L9-4 linear array (transmitting/receiving frequencies, 8/4 MHz). Afterward, specimens were stained for endothelial cells (CD31), vascular endothelial growth factor (VEGF), and cyclooxygenase 2 (COX-2). Tumor neovascularity was assessed in 4 different ways using a histomorphometry system (×100 magnification: (1) over the entire tumor; (2) in small sub-regions of interest (ROIs); (3) in the tumor periphery and centrally; and (4) in 3 regions of maximum marker expression (so-called hot spots). Results from specimens and from SHI were compared by linear regression. RESULTS: Fifty-four rats (64%) showed tumor growth, and 38 were successfully imaged. Subharmonic imaging depicted the tortuous morphologic characteristics of tumor neovessels and delineated small areas of necrosis. The immunohistochemical markers did not correlate with SHI measures over the entire tumor area or over small sub-ROIs (P > .18). However, when the specimens were subdivided into central and peripheral regions, COX-2 and VEGF correlated with SHI in the periphery (r = -0.42; P = .005; and r = -0.32; P = .049, respectively). CONCLUSIONS: When comparing quantitative contrast measures of tumor neovascularity to immunohistochemical markers of angiogenesis in xenograft models, ROIs corresponding to the biologically active region should be used to account for tumor heterogeneity.
Assuntos
Neoplasias da Mama/irrigação sanguínea , Meios de Contraste , Aumento da Imagem/métodos , Neovascularização Patológica/diagnóstico por imagem , Neovascularização Patológica/metabolismo , Ultrassonografia , Animais , Biomarcadores/metabolismo , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/metabolismo , Ciclo-Oxigenase 2/metabolismo , Modelos Animais de Doenças , Células Endoteliais/patologia , Feminino , Camundongos Nus , Ratos , Fator A de Crescimento do Endotélio Vascular/metabolismoRESUMO
OBJECTIVE: This study aimed to investigate the impact of microbubble degradation and flow velocity on Sub-Harmonic Aided Pressure Estimation (SHAPE), and to explore the correlation between subharmonic amplitude and pressure as a single factor. METHODS: We develop an open-loop vascular phantom platform system and utilize a commercial ultrasound machine and microbubbles for subharmonic imaging. Subharmonic amplitude was measured continuously at constant pressure and flow velocity to assess the impact of microbubble degradation. Flow velocity was varied within a range of 4-14 cm/s at constant pressure to investigate its relationship to subharmonic amplitude. Furthermore, pressure was varied within a range of 10-110 mm Hg at constant flow velocity to assess its isolated effect on subharmonic amplitude. RESULTS: Under constant pressure and flow velocity, subharmonic amplitude exhibited a continuous decrease at an average rate of 0.221 dB/min, signifying ongoing microbubble degradation during the experimental procedures. Subharmonic amplitude demonstrated a positive correlation with flow velocity, with a variation ratio of 0.423 dB/(cm/s). Under controlled conditions of microbubble degradation and flow velocity, a strong negative linear correlation was observed between pressure and subharmonic amplitude across different Mechanical Index (MI) settings (all R2 > 0.90). The sensitivity of SHAPE was determined to be 0.025 dB/mmHg at an MI of 0.04. CONCLUSION: The assessment of SHAPE sensitivity is affected by microbubble degradation and flow velocity. Excluding the aforementioned influencing factors, a strong linear negative correlation between pressure and subharmonic amplitude was still evident, albeit with a sensitivity coefficient lower than previously reported values.
Assuntos
Microbolhas , Imagens de Fantasmas , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão , Ultrassonografia/métodos , Meios de ContrasteRESUMO
RATIONALE AND OBJECTIVE: Subharmonic aided pressure estimation (SHAPE) is based on the inverse relationship between the subharmonic amplitude of ultrasound contrast microbubbles and ambient pressure. The aim of this study was to verify if SHAPE can accurately monitor disease progression in patients identified with portal hypertension. MATERIALS & METHODS: A modified Logiq 9 scanner with a 4C curvi-linear probe (GE, Waukesha, WI) was used to acquire SHAPE data (transmitting and receiving at 2.5 and 1.25 MHz, respectively) using Sonazoid (GE Healthcare, Oslo, Norway; FDA IND 124,465). Twenty-one (median age 59 years; 12 Males) of the 178 patients enrolled in this institutional review board approved study (14F.113) were identified as having clinically significant portal hypertension based on their hepatic venous pressure gradient results ≥ 10 mmHg. Repeat SHAPE examinations were done every 6.2 months. Liver function tests and clinical indicators were used to establish treatment response. RESULTS: Of the 21 portal hypertensive subjects, 11 had successful follow up scans with an average follow up time of 6.2 months. There was a significantly larger SHAPE signal reduction in the group who were classified as treatment responders (nâ¯=â¯10; -4.01±3.61 dB) compared to the single nonresponder (2.33 dB; p < 0.001). Results for responders matched the corresponding clinical outcomes of improved model for end stage liver disease (MELD) scores, improvement in underlying cause of portal hypertension, improved liver function tests and reduced ascites. CONCLUSION: SHAPE can potentially monitor disease progression in portal hypertensive patients and hence, may help clinicians in patient management. A larger study would further validate this claim.
Assuntos
Doença Hepática Terminal , Hipertensão Portal , Humanos , Hipertensão Portal/complicações , Hipertensão Portal/diagnóstico por imagem , Cirrose Hepática , Masculino , Microbolhas , Pessoa de Meia-Idade , Índice de Gravidade de Doença , UltrassonografiaRESUMO
The aim of this work was to establish the optimum acoustic characterisation approach and insonation transmit beam parameters for subharmonic signal generation with 'native' and 'altered' populations of a commonly-used microbubble contrast agent. Dynamic contrast-enhanced (DCE) ultrasound is a non-invasive method of imaging the microvasculature, typically implemented using harmonic imaging. Subharmonic imaging, in which echoes at half the fundamental frequency are detected, detects signals which are generated by the ultrasound contrast agents (UCAs) but not by tissue. However, optimal transmission parameters and furthermore, the optimum acoustic characterisation method have not been established. The subharmonic response of 'native' and 'altered' UCA, altered through decantation, was investigated at transmit centre frequencies 1.8-5 MHz and pulse lengths 1-8 cycles. The 'altered' UCA had reduced polydispersity (1-4 µm: 82% bubble volume), compared to 'native' (4-10 µm: 57% bubble volume). A custom-built narrow-band acoustic characterisation system was found to be more appropriate for acoustic characterisation compared to the commonly used broadband pulse-echo approach. Both UCA generated the highest subharmonic signal at pulse length of 3-cycles. The maximum 'native' subharmonic signal was generated at a transmit centre frequency of 1.9 MHz, corresponding to a subharmonic at 0.95 MHz. This optimal frequency increased in the 'altered' population to 2.3-2.5 MHz, bringing the subharmonic above 1 MHz and hence into a range amenable to clinical abdominal imaging transducers. The use of subharmonic signal detection coupled with a modified UCA size distribution has potential to significantly improve the quantification sensitivity and accuracy of DCE ultrasound imaging.
Assuntos
Meios de Contraste/química , Microbolhas , Fosfolipídeos/química , Hexafluoreto de Enxofre/química , Ultrassonografia/instrumentação , Humanos , Aumento da Imagem , Tamanho da Partícula , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador , Transdutores , Ondas UltrassônicasRESUMO
RATIONALE AND OBJECTIVES: Breast cancer is the leading type of cancer among women. Visualization and characterization of breast lesions based on vascularity kinetics was evaluated using three-dimensional (3D) contrast-enhanced ultrasound imaging in a clinical study. MATERIALS AND METHODS: Breast lesions (nâ¯=â¯219) were imaged using power Doppler imaging (PDI), 3D contrast-enhanced harmonic imaging (HI), and 3D contrast-enhanced subharmonic imaging (SHI) with a modified Logiq 9 ultrasound scanner using a 4D10L transducer. Quantitative metrics of vascularity derived from 3D parametric volumes (based on contrast perfusion; PER and area under the curve; AUC) were generated by off-line processing of contrast wash-in and wash-out. Diagnostic accuracy of these quantitative vascular parameters was assessed with biopsy results as the reference standard. RESULTS: Vascularity was observed with PDI in 93 lesions (69 benign and 24 malignant), 3D HI in 8 lesions (5 benign and 3 malignant), and 3D SHI in 83 lesions (58 benign and 25 malignant). Diagnostic accuracy for vascular heterogeneity, PER, and AUC ranged from 0.52 to 0.75, while the best logistical regression model (vascular heterogeneity ratio, central PER, and central AUC) reached 0.90. CONCLUSION: 3D SHI successfully detects contrast agent flow in breast lesions and characterization of these lesions based on quantitative measures of vascular heterogeneity and 3D parametric volumes is promising.
Assuntos
Neoplasias da Mama , Meios de Contraste , Neoplasias da Mama/diagnóstico por imagem , Diagnóstico Diferencial , Feminino , Humanos , Imageamento Tridimensional , Ultrassonografia , Ultrassonografia DopplerRESUMO
Therapeutic microbubbles could make an important contribution to the diagnosis and treatment of cancer. Acoustic characterisation was performed on microfluidic generated microbubble populations that either were bare or had liposomes attached. Through the use of broadband attenuation techniques (3-8 MHz), the shell stiffness was measured to be 0.72 ± 0.01 and 0.78 ± 0.05 N/m and shell friction was 0.37 ± 0.05 and 0.74 ± 0.05 × 10-6 kg/s for bare and liposome-loaded microbubbles, respectively. Acoustic scatter revealed that liposome-loaded microbubbles had a lower subharmonic threshold, occurring from a peak negative pressure of 50 kPa, compared with 200 kPa for equivalent bare microbubbles. It was found that liposome loading had a negligible effect on the destruction threshold for this microbubble type, because at a mechanical index >0.4 (570 kPa), 80% of both populations were destroyed.
Assuntos
Meios de Contraste , Lipossomos , Microbolhas , Ondas UltrassônicasRESUMO
Contrast-enhanced intra-vascular ultrasound (CE-IVUS) imaging could provide clinicians a valuable tool to assess cardiovascular risk and guide the choice of therapeutic strategies. In this technical note, we evaluated the feasibility of combining subharmonic and ultraharmonic imaging to improve the performance of CE-IVUS. Vessel phantoms perfused with phospholipid-shelled ultrasound contrast agents were visualized using subharmonic, ultraharmonic and combined CE-IVUS modes with commercial peripheral and coronary imaging catheters. Flow channels as small as 0.8 mm and 0.5 mm were imaged at 12-MHz and 30-MHz transmit frequencies, respectively. Subharmonic and ultraharmonic imaging modes achieved a contrast-to-tissue ratio (CTR) up to 18.1 ± 1.8 dB and 19.6 ± 1.9 dB at 12-MHz, and 8.8 ± 1.8 and 12.5 ± 1.1 dB at 30-MHz transmit frequencies, respectively. Combining these modes improved the CTR to 32.5 ± 3.0 dB and 25.0 ± 1.6 dB at 12-MHz and 30-MHz transmit frequencies. These results underscore the potential of combined-mode CE-IVUS imaging. Furthermore, the demonstration of this approach with commercial catheters may serve as a first step toward the clinical translation of CE-IVUS.
Assuntos
Meios de Contraste , Vasos Coronários/diagnóstico por imagem , Aumento da Imagem/métodos , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador , Ultrassonografia de Intervenção/métodos , Acústica , Estudos de Viabilidade , FosfolipídeosRESUMO
This project compared quantifiable measures of tumor vascularity obtained from contrast-enhanced high frequency (HF) and low frequency (LF) subharmonic ultrasound imaging (SHI) to 3 immunohistochemical markers of angiogenesis in a murine breast cancer model (since angiogenesis is an important marker of malignancy and the target of many novel cancer treatments). Nineteen athymic, nude, female rats were implanted with 5×10(6) breast cancer cells (MDA-MB-231) in the mammary fat pad. The contrast agent Definity (Lantheus Medical Imaging, N Billerica, MA) was injected in a tail vein (dose: 180µl/kg) and LF pulse-inversion SHI was performed with a modified Sonix RP scanner (Analogic Ultrasound, Richmond, BC, Canada) using a L9-4 linear array (transmitting/receiving at 8/4MHz in SHI mode) followed by HF imaging with a Vevo 2100 scanner (Visualsonics, Toronto, ON, Canada) using a MS250 linear array transmitting and receiving at 24MHz. The radiofrequency data was filtered using a 4th order IIR Butterworth bandpass filter (11-13MHz) to isolate the subharmonic signal. After the experiments, specimens were stained for endothelial cells (CD31), vascular endothelial growth factor (VEGF) and cyclooxygenase-2 (COX-2). Fractional tumor vascularity was calculated as contrast-enhanced pixels over all tumor pixels for SHI, while the relative area stained over total tumor area was calculated from specimens. Results were compared using linear regression analysis. Out of 19 rats, 16 showed tumor growth (84%) and 11 of them were successfully imaged. HF SHI demonstrated better resolution, but weaker signals than LF SHI (0.06±0.017 vs. 0.39±0.059; p<0.001). The strongest overall correlation in this breast cancer model was between HF SHI and VEGF (r=-0.38; p=0.03). In conclusion, quantifiable measures of tumor neovascularity derived from contrast-enhanced HF SHI appear to be a better method than LF SHI for monitoring angiogenesis in a murine xenograft model of breast cancer (corresponding in particular to the expression of VEGF); albeit based on a limited sample size.