Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 324
Filtrar
Mais filtros

País/Região como assunto
Intervalo de ano de publicação
1.
Eur J Neurosci ; 60(3): 4148-4168, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39001625

RESUMO

The conventional medical paradigm often focuses on deficits and impairments, failing to capture the rich tapestry of experiences and abilities inherent in neurodiversity conditions. In this article, we introduce the 3E-Cognition perspective, offering a paradigm shift by emphasizing the dynamic interplay between the brain, body, and environment in shaping cognitive processes. The perspective fosters a more inclusive and supportive understanding of neurodiversity, with potential applications across various domains such as education, workplace, and healthcare. We begin by introducing the 3E-Cognition principles: embodied, environmentally scaffolded, and enactive. Then, we explore how the 3E-Cognition perspective can be applied to create inclusive environments and experiences for neurodiverse individuals. We provide examples in the realms of education, workplace, and healthcare. In all of these domains, spaces, methodologies, epistemologies, and roles that cater to diverse needs and strengths can be designed using the 3E principles. Finally, we discuss the challenges and benefits of implementing the 3E-Cognition perspective. We focus on the need for technological advancements and research in complex real-world scenarios; we suggest mobile brain/body imaging is a possible solution. We furthermore highlight the importance of recognizing and valuing the diverse manners of experiencing and interacting with the world, the promotion of diverse well-being, and the facilitation of innovation and creativity. Thus, we conclude that the 3E-Cognition perspective offers a groundbreaking approach to understanding and supporting neurodiversity: by embracing the inherent interconnectedness of the brain, body, and environment, we can create a more inclusive and supportive world.


Assuntos
Cognição , Neurociências , Humanos , Encéfalo/fisiologia , Cognição/fisiologia , Meio Ambiente , Neurociências/métodos
2.
Magn Reson Med ; 2024 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-39301784

RESUMO

PURPOSE: Transmit arrays for body imaging have characteristics of both volume and local transmit coils. This study evaluates two specific absorption rate (SAR) aspects, local and whole-body SAR, of arrays for body imaging at 7 T and also for a 3 T birdcage. METHODS: Simulations were performed for six antenna arrays at 7 T and one 3 T birdcage. Local SAR matrices and the whole-body SAR matrix were computed and evaluated with random shims. A set of reduced local SAR matrices was determined by removing all matrices dominated by the whole-body SAR matrix. RESULTS: The results indicate that all RF transmit coils for body imaging in this study are constrained by the local SAR limit. The ratio between local and whole-body SAR is nevertheless smaller for arrays with large FOV, as these arrays also expose a larger part of the human body. By using the whole-body SAR matrix, the number of local SAR matrices can be reduced (e.g., 33.3% matrices remained for an 8-channel local array and 89.7% for a 30-channel remote array; 12.1% for the 3 T birdcage). CONCLUSION: For transmit antenna arrays used for body imaging at 7 T as well as for the 3 T birdcage, all evaluated cases show that the local SAR limit was reached before reaching the whole-body SAR limit. Nevertheless, the whole-body SAR matrix can be used to reduce the number of local SAR matrices, which is important to reduce memory and computing time for a virtual observation points (VOP) compression. This step can be included as a pre-compression prior to a VOP compression.

3.
Magn Reson Med ; 92(6): 2343-2357, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-39051729

RESUMO

PURPOSE: Diffusion-weighted imaging (DWI) suffers from geometric distortion and chemical shift artifacts due to the commonly used Echo Planar Imaging (EPI) trajectory. Even with fat suppression in DWI, severe B0 and B1 variations can result in residual fat, which becomes both a source of image artifacts and a confounding factor in diffusion-weighted contrast in distinguishing benign and malignant tissues. This work presents a method for acquiring distortion-free diffusion-weighted images using spatiotemporal acquisition and joint reconstruction. Water-fat separation is performed by chemical-shift encoding. METHODS: Spatiotemporal acquisition is employed to obtain distortion-free images at a series of echo times. Chemical-shift encoding is used for water-fat separation. Reconstruction and separation are performed jointly in the spat-spectral domain. To address the shot-to-shot motion-induced phase in DWI, an Fast Spin Echo (FSE)-based phase navigator is incorporated into the sequence to obtain distortion-free phase information. The proposed method was validated in phantoms and in vivo for the brain, head and neck, and breast. RESULTS: The proposed method enables the acquisition of distortion-free diffusion-weighted images in the presence of B0 field inhomogenieties commonly observed in the body. Water and fat components are separated with no obvious spectral leakage artifacts. The estimated Apparent Diffusion Coefficient (ADC) is comparable to that of multishot DW-EPI. CONCLUSION: Distortion-free, water-fat separated diffusion-weighted images in body can be obtained through the utilization of spatiotemporal acquisition and joint reconstruction methods.


Assuntos
Tecido Adiposo , Algoritmos , Artefatos , Encéfalo , Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Tecido Adiposo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imagem Ecoplanar/métodos , Feminino , Encéfalo/diagnóstico por imagem , Água/química , Mama/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Cabeça/diagnóstico por imagem
4.
Magn Reson Med ; 91(2): 513-529, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37705412

RESUMO

PURPOSE: To increase the RF coil performance and RF management for body imaging at 10.5 T by validating and evaluating a high-density 16-channel transceiver array, implementing virtual observation points (VOPs), and demonstrating specific absorption rate (SAR) constrained imaging in vivo. METHODS: The inaccuracy of the electromagnetic model of the array was quantified based on B1 + and SAR data. Inter-subject variability was estimated using a new approach based on the relative SAR deviation of different RF shims between human body models. The pTx performance of the 16-channel array was assessed in simulation by comparison to a previously demonstrated 10-channel array. In vivo imaging of the prostate was performed demonstrating SAR-constrained static RF shimming and acquisition modes optimized for refocused echoes (AMORE). RESULTS: The model inaccuracy of 29% and the inter-subject variability of 85% resulted in a total safety factor of 1.91 for pelvis studies. For renal and cardiac imaging, inter-subject variabilities of 121% and 141% lead to total safety factors of 2.25 and 2.45, respectively. The shorter wavelength at 10.5 T supported the increased element density of the 16-channel array which in turn outperformed the 10-channel version for all investigated metrics. Peak 10 g local SAR reduction of more than 25% without a loss of image quality was achieved in vivo, allowing a theoretical improvement in measurement efficiency of up to 66%. CONCLUSIONS: By validating and characterizing a 16-channel dipole transceiver array, this work demonstrates, for the first time, a VOP-enabled RF coil for human torso imaging enabling increased pTx performance at 10.5 T.


Assuntos
Imageamento por Ressonância Magnética , Próstata , Masculino , Humanos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Desenho de Equipamento , Simulação por Computador , Ondas de Rádio
5.
Eur Radiol ; 34(10): 6688-6700, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38637427

RESUMO

OBJECTIVE: To assess the clinical impact of regular whole-body magnetic resonance imaging (WBMRI) surveillance in myxoid liposarcoma patients. METHODS: This was a retrospective cohort study of myxoid liposarcoma patients who underwent at least one WBMRI at our institution between October 2006 and December 2020. The effect of WBMRI on clinical management, namely treatment modification or additional diagnostic investigations was studied. A standardised WBMRI surveillance protocol was instituted in 2015. We compared patient outcomes for the metastatic patients who had and had not received regular WBMRI surveillance and performed survival analysis for both subgroups. RESULTS: Of the 56 patients (60.7% male, median age: 48.1 years) who underwent 345 WBMRI, 17 (30.3%) had metastases, and 168 WBMRI were performed in this group. The median imaging follow-up for the entire cohort was 35 months; the metastatic group had a median follow-up of 42 months. WBMRI changed the clinical management in 13 (76.5%) metastatic patients, with 33 instances of treatment modification. Thirty-five lesions were labelled 'indeterminate,' 16 (45.7%) had additional investigations/interventions, and 4 (11.4%) were confirmed to be metastatic. Twenty-one metastatic lesions were missed initially on WBMRI and confirmed on subsequent WBMRI, of which 5 (23.8%) were clinically significant. The 5-year survival since the detection of metastasis was better in the regular surveillance subgroup (85.7% vs. 45%), but this was not statistically significant (p = 0.068). Five patients (8.9%) developed their first metastasis more than 5 years after diagnosing the primary lesion. CONCLUSION: Regular WBMRI surveillance of myxoid liposarcoma patients considerably impacts clinical management by frequently influencing treatment decisions. CLINICAL RELEVANCE STATEMENT: WBMRI has been recently recommended as an imaging option for the staging and surveillance of myxoid liposarcoma patients. Our study highlights the impact of regular WBMRI surveillance on the clinical management of these patients and how it affects their survival.


Assuntos
Lipossarcoma Mixoide , Imageamento por Ressonância Magnética , Estadiamento de Neoplasias , Imagem Corporal Total , Humanos , Lipossarcoma Mixoide/diagnóstico por imagem , Lipossarcoma Mixoide/patologia , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Imagem Corporal Total/métodos , Adulto , Idoso
6.
Eur Radiol ; 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-38995385

RESUMO

OBJECTIVES: To determine the feasibility and diagnostic accuracy of fast whole-body magnetic resonance imaging (WB-MRI) compared to whole-body computed tomography (WB-CT) in detecting injuries of slightly to moderately injured trauma patients. MATERIALS AND METHODS: In a prospective single-center approach, trauma patients from convenience sampling with an expected Abbreviated Injury Scale (AIS) score ≤ 3 at admission, received an indicated contrast-enhanced WB-CT (reference standard) and a plain WB-MRI (index test) voluntarily up to five days after trauma. Two radiologists, blinded to the WB-CT findings, evaluated the absence or presence of injuries with WB-MRI in four body regions: head, torso, axial skeleton, and upper extremity. Diagnostic accuracy was determined using sensitivity, specificity, positive predictive value, and negative predictive value by body region. RESULTS: Between June 2019 and July 2021, 40 patients were assessed for eligibility of whom 35 (median age (interquartile range): 50 (32.5) years; 26 men) received WB-MRI. Of 140 body regions (35 patients × 4 regions), 31 true positive, 6 false positive, 94 true negative, and 9 false negative findings were documented with WB-MRI. Thus, plain WB-MRI achieved a total sensitivity of 77.5% (95%-confidence interval (CI): (61.6-89.2%)), specificity of 94% (95%-CI: (87.4-97.8%)), and diagnostic accuracy of 89.3% (95%-CI: (82.9-93.9%)). Across the four regions sensitivity and specificity varied: head (66.7%/93.1%), torso (62.5%/96.3%), axial skeleton (91.3%/75%), upper extremity (33.3%/100%). Both radiologists showed substantial agreement on the WB-MRI reading (Cohen's Kappa: 0.66, 95%-CI: (0.51-0.81)). CONCLUSION: Regarding injury detection, WB-MRI is feasible in slightly to moderately injured trauma patients, especially in the axial skeleton. CLINICAL RELEVANCE STATEMENT: Besides offering a radiation-free approach, whole-body MRI detects injuries almost identically to whole-body CT in slightly to moderately injured trauma patients, who comprise a relevant share of all trauma patients. KEY POINTS: Whole-body MRI could offer radiation-free injury detection in slightly to moderately injured trauma patients. Whole-body MRI detected injuries almost identically compared to whole-body CT in this population. Whole-body MRI could be a radiation-free approach for slightly to moderately injured young trauma patients.

7.
Eur Radiol ; 2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39075300

RESUMO

OBJECTIVES: Li-Fraumeni syndrome (LFS) is a cancer syndrome associated with early-onset neoplasias. The use of whole-body magnetic resonance imaging (WBMRI) is recommended for regular cancer screening, however, evidence supporting the benefits in asymptomatic LFS patients is limited. This study aims to assess the clinical utility of WBMRI in germline TP53 mutation carriers at baseline and follow-up. MATERIALS AND METHODS: We systematically searched PubMed, Cochrane, and Embase databases for studies evaluating WBMRI as an early detection method for tumor screening in patients with LFS. We pooled the prevalence of the included variables along with their corresponding 95% confidence intervals (CIs). Statistical analyses were performed using R software, version 4.3.1. RESULTS: From 1687 results, 11 comprising 703 patients (359 females (51%); with a median age of 32 years (IQR 1-74)) were included. An estimated detection rate of 31% (95% CI: 0.28, 0.34) for any suspicious lesions was found in asymptomatic TP53 carriers who underwent baseline WBMRI. A total of 277 lesions requiring clinical follow-up were identified in 215 patients. Cancer was confirmed in 46 lesions across 39 individuals. The estimated cancer diagnosis rate among suspicious lesions was 18% (95% CI: 0.13, 0.25). WBMRI detected 41 of the 46 cancers at an early-disease stage, with an overall detection rate of 6% (95% CI: 0.05, 0.08). The incidence rate was 2% per patient round of WBMRI (95% CI: 0.01, 0.04), including baseline and follow-up. CONCLUSION: This meta-analysis provides evidence that surveillance with WBMRI is effective in detecting cancers in asymptomatic patients with LFS. CLINICAL RELEVANCE STATEMENT: Our study demonstrates that whole-body MRI is an effective tool for early cancer detection in asymptomatic Li-Fraumeni Syndrome patients, highlighting its importance in surveillance protocols to improve diagnosis and treatment outcomes. KEY POINTS: Current evidence for whole-body MRI screening of asymptomatic Li-Fraumeni Syndrome (LFS) patients remains scarce. Whole-body MRI identified 41 out of 46 cancers at an early stage, achieving an overall detection rate of 6%. Whole-body MRI surveillance is a valuable method for detecting cancers in asymptomatic LFS patients.

8.
Skeletal Radiol ; 53(9): 1815-1831, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39007948

RESUMO

Metastatic disease and myeloma present unique diagnostic challenges due to their multifocal nature. Accurate detection and staging are critical for determining appropriate treatment. Bone scintigraphy, skeletal radiographs and CT have long been the mainstay for the assessment of these diseases, but have limitations, including reduced sensitivity and radiation exposure. Whole-body MRI has emerged as a highly sensitive and radiation-free alternative imaging modality. Initially developed for skeletal screening, it has extended tumor screening to all organs, providing morphological and physiological information on tumor tissue. Along with PET/CT, whole-body MRI is now accepted for staging and response assessment in many malignancies. It is the first choice in an ever increasing number of cancers (such as myeloma, lobular breast cancer, advanced prostate cancer, myxoid liposarcoma, bone sarcoma, …). It has also been validated as the method of choice for cancer screening in patients with a predisposition to cancer and for staging cancers observed during pregnancy. The current and future challenges for WB-MRI are its availability facing this number of indications, and its acceptance by patients, radiologists and health authorities. Guidelines have been developed to optimize image acquisition and reading, assessment of lesion response to treatment, and to adapt examination designs to specific cancers. The implementation of 3D acquisition, Dixon method, and deep learning-based image optimization further improve the diagnostic performance of the technique and reduce examination durations. Whole-body MRI screening is feasible in less than 30 min. This article reviews validated indications, recent developments, growing acceptance, and future perspectives of whole-body MRI.


Assuntos
Imageamento por Ressonância Magnética , Mieloma Múltiplo , Imagem Corporal Total , Humanos , Imagem Corporal Total/métodos , Imageamento por Ressonância Magnética/métodos , Mieloma Múltiplo/diagnóstico por imagem , Estadiamento de Neoplasias , Metástase Neoplásica/diagnóstico por imagem , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Previsões
9.
Radiol Med ; 129(9): 1352-1368, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38990426

RESUMO

Acknowledging the increasing use of whole-body magnetic resonance imaging (WB-MRI) in the oncological setting, we conducted a narrative review focusing on practical aspects of the examination and providing a synthesis of various acquisition protocols described in the literature. Firstly, we addressed the topic of patient preparation, emphasizing methods to enhance examination acceptance. This included strategies for reducing anxiety and patient distress, improving staff-patient interactions, and increasing overall patient comfort. Secondly, we analysed WB-MRI acquisition protocols recommended in existing imaging guidelines, such as MET-RADS-P, MY-RADS, and ONCO-RADS, and provided an overview of acquisition protocols reported in the literature regarding other expanding applications of WB-MRI in oncology, in patients with breast cancer, ovarian cancer, melanoma, colorectal and lung cancer, lymphoma, and cancers of unknown primary. Finally, we suggested possible acquisition parameters for whole-body images across MR systems from three different vendors.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias , Guias de Prática Clínica como Assunto , Imagem Corporal Total , Humanos , Imagem Corporal Total/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias/diagnóstico por imagem
10.
J Radiol Prot ; 44(3)2024 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-39121874

RESUMO

In computed tomography (CT), organ dose modulation (ODM) reduces radiation exposure from the anterior side to reduce radiation dose received by the radiosensitive organs located anteriorly. We investigated the effects of ODM applied to a part of the scan range on radiation dose in body CT. The thorax and thoraco-abdominopelvic region of an anthropomorphic whole-body phantom were imaged with and without ODM. ODM was applied to various regions, and the tube current modulation curves were compared. Additionally, the dose indices were compared with and without ODM in thoracic and thoraco-abdominopelvic CTs in 800 patients. ODM was applied to the thyroid in male patients and to the thyroid and breast in female patients. In phantom imaging of the thorax, the application of ODM below the scan range decreased the tube current, and that to the breast showed a further decrease. Decreased tube current was also observed in phantom imaging of the thoraco-abdominopelvic regions with ODM below the scan range, and the application of ODM to the whole scan range, thyroid, breast, and both thyroid and breast further reduced the tube current in the region to which ODM was applied. In patient imaging, the dose indices were significantly lower with ODM than without ODM, regardless of the scan range or sex. The absolute reduction in dose-length product was larger for thoraco-abdominopelvic CT (male, 43.2 mGy cm; female, 59.7 mGy cm) than for thoracic CT (male, 30.8 mGy cm; female, 37.6 mGy cm) in both sexes, indicating dose reduction in the abdominopelvic region to which ODM was not applied. In conclusion, The application of ODM in body CT reduces radiation dose not only in the region to which ODM is applied but also outside the region. In radiation dose management, it should be considered that even ODM applied to a limited region affects the dose indices.


Assuntos
Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Adulto , Proteção Radiológica , Glândula Tireoide/efeitos da radiação , Glândula Tireoide/diagnóstico por imagem , Pessoa de Meia-Idade , Mama/diagnóstico por imagem , Mama/efeitos da radiação , Idoso , Imagem Corporal Total
11.
NMR Biomed ; 36(6): e4906, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36640112

RESUMO

Chemical exchange saturation transfer (CEST) MRI has gained recognition as a valuable addition to the molecular imaging and quantitative biomarker arsenal, especially for characterization of brain tumors. There is also increasing interest in the use of CEST-MRI for applications beyond the brain. However, its translation to body oncology applications lags behind those in neuro-oncology. The slower migration of CEST-MRI to non-neurologic applications reflects the technical challenges inherent to imaging of the torso. In this review, we discuss the application of CEST-MRI to oncologic conditions of the breast and torso (i.e., body imaging), emphasizing the challenges and potential solutions to address them. While data are still limited, reported studies suggest that CEST signal is associated with important histology markers such as tumor grade, receptor status, and proliferation index, some of which are often associated with prognosis and response to therapy. However, further technical development is still needed to make CEST a reliable clinical application for body imaging and establish its role as a predictive and prognostic biomarker.


Assuntos
Neoplasias Encefálicas , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Neoplasias Encefálicas/patologia , Encéfalo/patologia , Prognóstico , Imagem Molecular
12.
Eur J Nucl Med Mol Imaging ; 50(5): 1318-1328, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36529840

RESUMO

PURPOSE: Image quality control is a prerequisite for applying PET/CT. This study aimed to develop an artificial intelligence-driven real-time and accurate whole-body [18F]FDG PET/CT image quality assessment system. METHODS: This study included 173 patients (age, 59 ± 12 years; 66.3% males) with whole-body [18F]FDG PET/CT imaging. Images of ten patients were used as an educational set. Images of the rest 163 patients were reconstructed to 952 images by simulating several scanning times and randomly split into training (60%, 98 patients, 578 images), validation (20%, 33 patients, 192 images), and test (20%, 32 patients,182 images) sets. Two experienced physicians (R1 and R2) independently assessed the image quality of thorax, abdomen, and pelvis region twice (R1a and b; R2a and b), 1 month apart, using a 5-point Likert scale. Objective image quality metrics were extracted from the mediastinal blood pool, three liver levels, and the bilateral gluteus maximus. The developed convolutional neural networks for image quality assessment (IQA-CNNs) generated the subjective quality scores and objective image metrics. The IQA-CNNs and physicians' performances were compared for localization accuracy, score agreement, and process time. RESULTS: The physicians demonstrated good inter- and intra-rater subjective assessment agreement, with kappa coefficients (R1a vs. R2a, R1a vs. R1b, R2a vs. R2b, and R1a vs. R2b) of 0.78, 0.77, 0.76, and 0.80. The IQA-CNNs and R1 or R2 agreed in the subjective assessments, with kappa coefficients of 0.79 and 0.78. IQA-CNNs and R1 or R2 also agreed in their objective image quality assessment (ICC > 0.60). The IQA-CNNs evaluation speed was 200 times faster than the manual assessment. CONCLUSION: An automated system for rapid assessment of [18F]FDG PET/CT image quality was developed, showing comparable performance to senior physicians. The system generates a comprehensive and detailed image quality assessment report, including subjective visual scores and objective image metrics for various anatomical regions.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Inteligência Artificial , Redes Neurais de Computação , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos
13.
J Magn Reson Imaging ; 57(6): 1621-1640, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36748806

RESUMO

Magnetic materials in tissue, such as iron, calcium, or collagen, can be studied using quantitative susceptibility mapping (QSM). To date, QSM has been overwhelmingly applied in the brain, but is increasingly utilized outside the brain. QSM relies on the effect of tissue magnetic susceptibility sources on the MR signal phase obtained with gradient echo sequence. However, in the body, the chemical shift of fat present within the region of interest contributes to the MR signal phase as well. Therefore, correcting for the chemical shift effect by means of water-fat separation is essential for body QSM. By employing techniques to compensate for cardiac and respiratory motion artifacts, body QSM has been applied to study liver iron and fibrosis, heart chamber blood and placenta oxygenation, myocardial hemorrhage, atherosclerotic plaque, cartilage, bone, prostate, breast calcification, and kidney stone.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética , Masculino , Humanos , Imageamento por Ressonância Magnética/métodos , Fígado , Ferro , Abdome , Encéfalo , Mapeamento Encefálico
14.
J Magn Reson Imaging ; 2023 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-37675995

RESUMO

BACKGROUND: Accurate identification of high-risk multiple myeloma (HRMM) is important for prognostication. The degree of diffuse infiltration patterns on magnetic resonance imaging (MRI) is associated with patient prognosis in multiple myeloma. However, objective indexes to determine the degree of diffuse infiltration patterns are unavailable. PURPOSE: To investigate whether qualitative and quantitative evaluations of diffuse infiltration patterns on MRI could identify HRMM. STUDY TYPE: Retrospective. SUBJECTS: Totally, 180 patients (79 HRMM and 101 standard-risk MM) were assessed. The presence of del(17p), t(4;14), t(14;16), t(14;20), gain 1q, and/or p53 mutations was considered to indicate HRMM. FIELD STRENGTH/SEQUENCE: 3.0 T/diffusion-weighted whole-body imaging with background body signal suppression (DWIBS), modified Dixon chemical-shift imaging Quant (mDIXON Quant), and short TI inversion recovery (STIR). ASSESSMENT: Qualitative analysis involved assessing the degree of diffuse marrow infiltration (mild, moderate, or severe), and quantitative analysis involved evaluating apparent diffusion coefficient (ADC), fat fraction (FF), and T2* values. Clinical data such as sex, age, hemoglobin, serum albumin, serum calcium, serum creatinine, serum lactate dehydrogenase, ß2-microglobulin, and bone marrow plasma cells (BMPCs) were also included. STATISTICAL TESTS: Univariate and multivariate analyses, receiver operating characteristic (ROC) curve. P < 0.05 was considered statistically significant. RESULTS: The high-risk group had significantly higher ADC and T2* and lower FF compared with the standard-risk group. Multivariate analysis indicated BMPCs as a significant independent risk factor for HRMM (odds ratio (OR) = 1.019, 95% CI 1.004-1.033), while FF was a significant independent protective factor associated with HRMM (OR = 0.972, 95% CI 0.946-0.999). The combination of BMPCs and FF achieved the highest areas under the curve (AUC) of 0.732, with sensitivity and specificity of 70.9% and 68.3%, respectively. DATA CONCLUSION: Compared with qualitative analysis, FF value was independently associated with HRMM. The quantitative features of diffuse marrow infiltration on MRI scans are more effective in detecting HRMM. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 2.

15.
Eur Radiol ; 33(3): 1719-1728, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36269371

RESUMO

OBJECTIVES: The study aimed to assess the efficiency of whole-body high-resolution compressed sensing-sensitivity encoding isotropic T1-Weighted Dixon (CSI-T1W-Dixon) scans in evaluating bone metastasis. METHODS: Forty-five high-risk prostate cancer patients with bone metastases were enrolled prospectively and underwent whole-body MRI sequences, which included the following: pre- and post-contrast CSI-T1W-Dixon and conventional multi-planar T1-Weighted Dixon (CMP-T1W-Dixon) (coronal, sagittal, and axial scans), short tau inversion recovery (STIR), and DWI. Comparison between the CMP-T1W-Dixon and CSI-T1W-Dixon images was done for the subjective image quality, the quantitative contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR). Furthermore, the diagnostic performance based on per-lesion and per-patient basis utilizing non-contrast T1-weighted (T1)/T1+ contrasted T1-weighted (T1C)/T1 + T1C + STIR + DWI sequences was compared between the CSI-T1W-Dixon and CMP-T1W-Dixon methods using reference standards (combining biopsy data and 6-month imaging follow-up). RESULT: The CSI-T1W-Dixon images produced fewer image artifacts in the axial and coronal planes compared to the CMP-T1W-Dixon images. Also, the CSI-T1W-Dixon images provided better a CNR in fat-only images of all three planes and water-only images of the axial plane (p < 0.05). The CSI-T1W-Dixon showed a higher sensitivity than the CMP-T1W-Dixon techniques in analyzing T1-only images on a per-lesion basis (82.7% vs. 53.8% for sensitivity, p = 0.03). On a per-patient basis, no difference was found in the diagnostic capacity between the CSI-T1W-Dixon and CMP-T1W-Dixon sequences either alone or in combinations (p = 0.57-1). CONCLUSION: High-resolution CSI-T1W-Dixon with higher image quality and diagnostic capacity can replace the CMP-T1W-Dixon method in evaluating bone metastasis in clinical practice. KEY POINTS: • Compressed sensing isotropic acquisition for 3D T1-weighted Dixon images can improve the image quality with fewer artifacts compared to the anisotropic multiplanar acquisition. • Compressed sensing isotropic acquisition can save 67% of scanning time compared to anisotropic multiplanar acquisition. • Compressed sensing isotropic 3D T1-weighted Dixon images can offer better diagnostic performance with higher sensitivity compared to anisotropic multiplanar images.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias da Próstata , Masculino , Humanos , Estudos de Viabilidade , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Imageamento Tridimensional/métodos , Razão Sinal-Ruído
16.
Eur Radiol ; 33(2): 863-871, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36169688

RESUMO

OBJECTIVE: To establish optimised diffusion weightings ('b-values') for acquisition of whole-body diffusion-weighted MRI (WB-DWI) for estimation of the apparent diffusion coefficient (ADC) in patients with metastatic melanoma (MM). Existing recommendations for WB-DWI have not been optimised for the tumour properties in MM; therefore, evaluation of acquisition parameters is essential before embarking on larger studies. METHODS: Retrospective clinical data and phantom experiments were used. Clinical data comprised 125 lesions from 14 examinations in 11 patients with multifocal MM, imaged before and/or after treatment with immunotherapy at a single institution. ADC estimates from these data were applied to a model to estimate the optimum b-value. A large non-diffusing phantom was used to assess eddy current-induced geometric distortion. RESULTS: Considering all tumour sites from pre- and post-treatment examinations together, metastases exhibited a large range of mean ADC values, [0.67-1.49] × 10-3 mm2/s, and the optimum high b-value (bhigh) for ADC estimation was 1100 (10th-90th percentile: 740-1790) s/mm2. At higher b-values, geometric distortion increased, and longer echo times were required, leading to reduced signal. CONCLUSIONS: Theoretical optimisation gave an optimum bhigh of 1100 (10th-90th percentile: 740-1790) s/mm2 for ADC estimation in MM, with the large range of optimum b-values reflecting the wide range of ADC values in these tumours. Geometric distortion and minimum echo time increase at higher b-values and are not included in the theoretical optimisation; bhigh in the range 750-1100 s/mm2 should be adopted to maintain acceptable image quality but performance should be evaluated for a specific scanner. KEY POINTS: • Theoretical optimisation gave an optimum high b-value of 1100 (10th-90th percentile: 740-1790) s/mm2 for ADC estimation in metastatic melanoma. • Considering geometric distortion and minimum echo time (TE), a b-value in the range 750-1100 s/mm2 is recommended. • Sites should evaluate the performance of specific scanners to assess the effect of geometric distortion and minimum TE.


Assuntos
Melanoma , Segunda Neoplasia Primária , Humanos , Estudos Retrospectivos , Imagem de Difusão por Ressonância Magnética/métodos , Melanoma/diagnóstico por imagem , Imagens de Fantasmas , Reprodutibilidade dos Testes
17.
Eur Radiol ; 33(1): 244-257, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35925384

RESUMO

OBJECTIVES: To compare the diagnostic accuracy of a single T2 Dixon sequence to the combination T1+STIR as anatomical sequences used for detecting tumoral bone marrow lesions in whole-body MRI (WB-MRI) examinations. METHODS: Between January 2019 and January 2020, seventy-two consecutive patients (55 men, 17 women, median age = 66 years) with solid (prostate, breast, neuroendocrine) cancers at high risk of metastasis or proven multiple myeloma (MM) prospectively underwent a WB-MRI examination including coronal T1, STIR, T2 Dixon and axial diffusion-weighted imaging sequences. Two radiologists independently assessed the combination of T1+STIR sequences and the fat+water reconstructions from the T2 Dixon sequence. The reference standard was established by consensus reading of WB-MRI and concurrent imaging available at baseline and at 6 months. Repeatability and reproducibility of MRI scores (presence and semi-quantitative count of lesions), image quality (SNR: signal-to-noise, CNR: contrast-to-noise, CRR: contrast-to-reference ratios), and diagnostic characteristics (Se: sensitivity, Sp: specificity, Acc: accuracy) were assessed per-skeletal region and per-patient. RESULTS: Repeatability and reproducibility were at least good regardless of the score, region, and protocol (0.67 ≤ AC1 ≤ 0.98). CRR was higher on T2 Dixon fat compared to T1 (p < 0.0001) and on T2 Dixon water compared to STIR (p = 0.0128). In the per-patient analysis, Acc of the T2 Dixon fat+water was higher than that of T1+STIR for the senior reader (Acc = +0.027 [+0.025; +0.029], p < 0.0001) and lower for the junior reader (Acc = -0.029 [-0.031; -0.027], p < 0.0001). CONCLUSIONS: A single T2 Dixon sequence with fat+water reconstructions offers similar reproducibility and diagnostic accuracy as the recommended combination of T1+STIR sequences and can be used for skeletal screening in oncology, allowing significant time-saving. KEY POINTS: • Replacement of the standard anatomic T1 + STIR WB-MRI protocol by a single T2 Dixon sequence drastically shortens the examination time without loss of diagnostic accuracy. • A protocol based on fat + water reconstructions from a single T2 Dixon sequence offers similar inter-reader agreement and a higher contrast-to-reference ratio for detecting lesions compared to the standard T1 + STIR protocol. • Differences in the accuracy between the two protocols are marginal (+ 3% in favor of the T2 Dixon with the senior reader; -3% against the T2 Dixon with the junior reader).


Assuntos
Mieloma Múltiplo , Masculino , Humanos , Feminino , Idoso , Mieloma Múltiplo/diagnóstico por imagem , Reprodutibilidade dos Testes , Imagem Corporal Total/métodos , Imageamento por Ressonância Magnética/métodos , Água
18.
Eur Radiol ; 33(7): 5045-5053, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36700955

RESUMO

OBJECTIVES: To compare short time inversion recovery (STIR) and T2 Dixon in the detection and grading of high signal intensity areas in bone marrow on whole-body MRI in healthy children. METHODS: Prospective study, including whole-body 1.5-T MRIs from 77 healthy children. Two experienced radiologists in consensus identified and graded areas of high bone marrow signal on STIR and T2-weighted (T2W) turbo spin echo (TSE) Dixon images (presence, extension) in two different sessions at an interval of at least 3 weeks. In a third session, a third observer joined the two readers for an additional consensus reading with all sequences available (substitute gold standard). RESULTS: Four hundred ninety of 545 (89.9%) high signal areas were visible on both sequences, while 27 (5.0%) were visible on STIR only and 28 (5.1%) on T2W Dixon only. Twenty-four of 27 (89%) lesions seen on STIR only, and 25/28 (89%) seen on T2W Dixon only, were graded as mildly increased signal intensity. The proportion of true positive high signal lesions was higher for the T2W Dixon images as compared to STIR (74.2% vs. 68.2%) (p = 0.029), while the proportion of false negatives was lower (25.9% vs. 31.7% (p = 0.035) for T2W Dixon and STIR, respectively). There was a moderate agreement between the T2W Dixon and STIR-based extension scores on a 0-4 scale, with a kappa of 0.45 (95% CI = 0.34-0.56). CONCLUSIONS: Most high signal bone marrow changes identified on a 1.5-T whole-body MRI were seen on both STIR and water-only T2W Dixon, underscoring the importance of using identical protocols when following bone-marrow signal changes over time. KEY POINTS: • Whole-body MRI is increasingly being used to diagnose and monitor diseases in children, such as chronic non-bacterial osteomyelitis, malignant/metastatic disease, and histiocytosis. • Standardized and validated imaging protocols, as well as reference standards by age for the growing skeleton are lacking. • Prospective single-center study showed that 90% of high signal bone marrow areas identified on a 1.5-T whole-body MRI in healthy children is seen on both STIR and water-only T2W Dixon, while 5% is seen on STIR only and 5% on T2W Dixon only.


Assuntos
Medula Óssea , Imageamento por Ressonância Magnética , Humanos , Criança , Medula Óssea/diagnóstico por imagem , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Imagem Corporal Total , Espectroscopia de Ressonância Magnética
19.
Pediatr Radiol ; 53(7): 1485-1496, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36920515

RESUMO

BACKGROUND: Whole-body magnetic resonance imaging (WB-MRI) is an increasingly used guideline-based imaging modality for oncological and non-oncological pathologies during childhood and adolescence. While diffusion-weighted imaging (DWI), a part of WB-MRI, enhances image interpretation and improves sensitivity, it also requires the longest acquisition time during a typical WB-MRI scan protocol. Interleaved short tau inversion recovery (STIR) DWI with simultaneous multi-slice (SMS) acquisition is an effective way to speed up examinations. OBJECTIVE: In this study of children and adolescents, we compared the acquisition time, image quality, signal-to-noise ratio (SNR) and apparent diffusion coefficient (ADC) values of an interleaved STIR SMS-DWI sequence with a standard non-accelerated DWI sequence for WB-MRI. MATERIALS AND METHODS: Twenty children and adolescents (mean age: 13.9 years) who received two WB-MRI scans at a maximum interval of 18 months, consisting of either standard DWI or SMS-DWI MRI, respectively, were included. For quantitative evaluation, the signal-to-noise ratio (SNR) was determined for b800 images and ADC maps of seven anatomical regions. Image quality evaluation was independently performed by two experienced paediatric radiologists using a 5-point Likert scale. The measurement time per slice stack, pause between measurements including shim and total measurement time of DWI for standard DWI and SMS-DWI were extracted directly from the scan data. RESULTS: When including the shim duration, the acquisition time for SMS-DWI was 43% faster than for standard DWI. Qualitatively, the scores of SMS-DWI were higher in six locations in the b800 images and four locations in the ADC maps. There was substantial agreement between both readers, with a Cohen's kappa of 0.75. Quantitatively, the SNR in the b800 images and the ADC maps did not differ significantly from one another. CONCLUSION: Whole body-MRI with SMS-DWI provided equivalent image quality and reduced the acquisition time almost by half compared to the standard WB-DWI protocol.


Assuntos
Imageamento por Ressonância Magnética , Imagem Corporal Total , Humanos , Adolescente , Criança , Estudos Prospectivos , Imagem Corporal Total/métodos , Reprodutibilidade dos Testes , Imagem de Difusão por Ressonância Magnética/métodos
20.
Arch Orthop Trauma Surg ; 143(11): 6875-6881, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37340223

RESUMO

INTRODUCTION: Preoperative planning of total hip arthroplasty (THA) using two-dimensional low-dose (2DLD) full-body imaging has gained popularity in recent years. The low-dose imaging system is said to produce a calibrated image with constant 1:1 magnification. However, the planning software used in conjunction with those images may introduce variations in the degree of magnification in 2DLD imaging, and this has not yet been investigated. The purpose of the present study was to quantify any variation in 2DLD image to assess the need for image calibration when using conventional planning software. METHODS: Postoperative 2DLD images from 137 patients were retrospectively evaluated. Only patients who underwent THA for primary osteoarthritis were included in the study cohort. The femoral head diameter was measured by two independent observers using both Orthoview™ and TraumaCad™ planning software programs. Actual sizes of the femoral head implants were extracted from surgical reports to calculate image magnification. Magnification measurement reliability was calculated with the intra-class correlation coefficient (ICC) index. RESULTS: Image magnification varied among cases (mean 133%, range 129-135%). There was no statistical difference in mean image magnification among the various implant sizes (p = 0.8). Mean observer and inter-observer reliability was rated excellent. CONCLUSION: THA planning with 2DLD imaging is subject to variation in magnification as analyzed with conventional planning software in this series. This finding is of paramount importance for surgeons using 2DLD imaging in preparation for THA since errors in magnification could affect the accuracy of preoperative planning and ultimately the clinical outcome.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Calibragem , Cuidados Pré-Operatórios/métodos , Articulação do Quadril/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA