Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 86
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Rapid Commun Mass Spectrom ; 38(4): e9687, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38212650

RESUMO

RATIONALE: The sampling throughput of immediate drop-on-demand technology (I.DOT) coupled with an open port sampling interface (OPSI) is limited by software communication. To enable much-needed high-throughput mass spectrometry (MS) analysis capabilities, a novel software was developed that allows for flexible sample selection from a 96-well plate and for maximized analysis throughput using I.DOT/OPSI-MS coupling. METHODS: Wells of a 96-well I.DOT plate were filled with propranolol solution and were used to test maximum sampling throughput strategies to minimize analysis time. Demonstration of chemical reaction monitoring was done using acid-catalyzed ring closure of 2,3-diaminonaphthalene (DAN) with nitrite to form 2,3-naphthotriazole (NAT). Analytes were detected in positive electrospray ionization mode using selected reaction monitoring. RESULTS: A maximum throughput of 1.54 s/sample (7.41 min/96-well plate with three technical replicates) was achieved, and it was limited by the peak width of the MS signal resulting in an occasional slight overlap between the peaks. Relative standard deviation was 10 ± 1% with all tested sampling strategies. Chemical reaction monitoring of DAN to NAT using nitrite was successfully accomplished with 2 s/sample throughout showing almost complete transformation in 10 min with no signal overlap. CONCLUSIONS: This work illustrates the development of a noncontact, automated I.DOT/OPSI-MS system with improved throughput achieved through an optimized software interface. Its achievable analysis time and precision make it a viable approach for drug discovery and in situ reaction monitoring studies.

2.
Anal Chem ; 95(44): 16418-16425, 2023 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-37888790

RESUMO

Here, we present a rapid droplet sampling interface (RDSI) electrospray ionization mass spectrometry (ESI-MS) system as a high-throughput, low-volume, noncontact, and minimal-carryover approach for characterization of liquids. Liquid characterization was achieved by combining droplet ejection with an open-face microflow capillary with a 2.5 µL/min continuous flow of carrier solvent. Through this implementation, single 0.3 nL droplets containing the analyte effectively mix with 4-8 nL of carrier solvent and create a combined electrospray plume. The carrier solvent continuously cleaned the system, eliminating carryover. A sampling rate of 5 Hz was achieved for droplets containing 1 µM propranolol or 5 µM leu-enkephalin with each droplet fully baseline-resolved (138 ± 32 ms baseline-to-baseline). Using a SCIEX API4000 mass spectrometer, a lower limit of quantification (LLOQ) of propranolol was 15 nM, corresponding to 1.16 fg of propranolol in the droplet, and was linear across 3 orders of magnitude. Quantitation could be achieved by adding an isotopically labeled internal standard, as done in conventional ESI. Signal transients were faster than the acquisition speed of the mass spectrometer, resulting in artificially high reproducibility of 15-30% RSD droplet-to-droplet. Analyte-solvent mixing ratios could be controlled by adjusting droplet positioning along the open-face capillary with an optimal position about 0.4 mm from the tip end. The range of analyte coverage was exemplified by measures of peptides and drugs in methanol, water, and buffer solutions. In a comparison to the Open Port Sampling Interface (OPSI) implemented on the same system, the RDSI had 78× greater sensitivity, 6× greater throughput and used significantly less carrier solvent.


Assuntos
Propranolol , Espectrometria de Massas por Ionização por Electrospray , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray/métodos , Peptídeos/análise , Solventes
3.
Anal Chem ; 95(39): 14521-14525, 2023 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-37738474

RESUMO

The rhizosphere is the narrow region of soil surrounding the roots of plants that is influenced by root exudates, root secretions, and associated microbial communities. This region is crucial to plant growth and development and plays a critical role in nutrient uptake, disease resistance, and soil transformation. Understanding the function of exogenous compounds in the rhizosphere starts with determining the spatiotemporal distribution of these molecular components. Using liquid microjunction surface-sampling probe mass spectrometry (LMJ-SSP-MS) and microfluidic devices with attached microporous membranes enables in situ, nondisruptive, and nondestructive spatiotemporal measurement of exogenous compounds from plant roots. However, long imaging times (>2 h) can negatively affect plant heath and limit temporal studies. Here, we present a novel strategy to optimize the number and location of sampling sites on these microporous membrane-covered microfluidic devices. This novel, "structure-driven" sampling workflow takes into consideration the channel structure of the microfluidic device to maximize sampling from the channels and minimize acquisition time (∼4× less time in some cases while providing similar chemical image accuracy), thus reducing stress on plants during in situ LMJ-SSP-MS analysis.


Assuntos
Microbiota , Solo , Espectrometria de Massas , Solo/química , Rizosfera , Raízes de Plantas/química , Microbiologia do Solo
4.
Inorg Chem ; 62(50): 20834-20843, 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-37811965

RESUMO

Targeted α therapy (TAT) of soft-tissue cancers using the α particle-emitting radionuclide 223Ra holds great potential because of its favorable nuclear properties, adequate availability, and established clinical use for treating metastatic prostate cancer of the bone. Despite these advantages, the use of 223Ra has been largely overshadowed by other α emitters due to its challenging chelation chemistry. A key criterion that needs to be met for a radionuclide to be used in TAT is its stable attachment to a targeting vector via a bifunctional chelator. The low charge density of Ra2+ arising from its large ionic radius weakens its electrostatic binding interactions with chelators, leading to insufficient complex stability in vivo. In this study, we synthesized and evaluated macropa-XL as a novel chelator for 223Ra. It bears a large 21-crown-7 macrocyclic core and two picolinate pendent groups, which we hypothesized would effectively saturate the large coordination sphere of the Ra2+ ion. The structural chemistry of macropa-XL was first established with the nonradioactive Ba2+ ion using X-ray diffraction and X-ray absorption spectroscopy, which revealed the formation of an 11-coordinate complex in a rare anti pendent-arm configuration. Subsequently, the stability constant of the [Ra(macropa-XL)] complex was determined via competitive cation exchange with 223Ra and 224Ra radiotracers and compared with that of macropa, the current state-of-the-art chelator for Ra2+. A moderate log KML value of 8.12 was measured for [Ra(macropa-XL)], which is approximately 1.5 log K units lower than the stability constant of [Ra(macropa)]. This relative decrease in Ra2+ complex stability for macropa-XL versus macropa was further probed using density functional theory calculations. Additionally, macropa-XL was radiolabeled with 223Ra, and the kinetic stability of the resulting complex was evaluated in human serum. Although macropa-XL could effectively bind 223Ra under mild conditions, the complex appeared to be unstable to transchelation. Collectively, this study sheds additional light on the chelation chemistry of the exotic Ra2+ ion and contributes to the small, but growing, number of chelator development efforts for 223Ra-based TAT.


Assuntos
Medicina Nuclear , Rádio (Elemento) , Humanos , Quelantes/química , Rádio (Elemento)/química , Radioisótopos/química , Cátions/química
5.
Inorg Chem ; 61(32): 12847-12855, 2022 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-35914099

RESUMO

Radioisotopes of metallic elements, or radiometals, are widely employed in both therapeutic and diagnostic nuclear medicine. For this application, chelators that efficiently bind the radiometal of interest and form a stable metal-ligand complex with it are required. Toward the development of new chelators for nuclear medicine, we recently reported a novel class of 18-membered macrocyclic chelators that is characterized by their ability to form stable complexes with both large and small rare-earth metals (Ln3+), a property referred to as dual size selectivity. A specific chelator in this class called py-macrodipa, which contains one pyridyl group within its macrocyclic core, was established as a promising candidate for 135La3+, 213Bi3+, and 44Sc3+ chelation. Building upon this prior work, here we report the synthesis and characterization of a new chelator called py2-macrodipa with two pyridyl units fused into the macrocyclic backbone. Its coordination chemistry with the Ln3+ series was investigated by NMR spectroscopy, X-ray crystallography, density functional theory (DFT) calculations, analytical titrations, and transchelation assays. These studies reveal that py2-macrodipa retains the expected dual size selectivity and possesses an enhanced thermodynamic affinity for all Ln3+ compared to py-macrodipa. By contrast, the kinetic stability of Ln3+ complexes with py2-macrodipa is only improved for the light, large Ln3+ ions. Based upon these observations, we further assessed the suitability of py2-macrodipa for use with 225Ac3+, a large radiometal with valuable properties for targeted α therapy. Radiolabeling and stability studies revealed py2-macrodipa to efficiently incorporate 225Ac3+ and to form a complex that is inert in human serum over 3 weeks. Although py2-macrodipa does not surpass the state-of-the-art chelator macropa for 225Ac3+ chelation, it does provide another effective 225Ac3+ chelator. These studies shed light on the fundamental coordination chemistry of the Ln3+ series and may inspire future chelator design efforts.


Assuntos
Complexos de Coordenação , Elementos da Série dos Lantanídeos , Metais Terras Raras , Quelantes/química , Complexos de Coordenação/química , Humanos , Elementos da Série dos Lantanídeos/química , Ligantes , Radioisótopos/química
6.
J Chem Inf Model ; 62(1): 116-128, 2022 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-34793155

RESUMO

Despite the recent availability of vaccines against the acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the search for inhibitory therapeutic agents has assumed importance especially in the context of emerging new viral variants. In this paper, we describe the discovery of a novel noncovalent small-molecule inhibitor, MCULE-5948770040, that binds to and inhibits the SARS-Cov-2 main protease (Mpro) by employing a scalable high-throughput virtual screening (HTVS) framework and a targeted compound library of over 6.5 million molecules that could be readily ordered and purchased. Our HTVS framework leverages the U.S. supercomputing infrastructure achieving nearly 91% resource utilization and nearly 126 million docking calculations per hour. Downstream biochemical assays validate this Mpro inhibitor with an inhibition constant (Ki) of 2.9 µM (95% CI 2.2, 4.0). Furthermore, using room-temperature X-ray crystallography, we show that MCULE-5948770040 binds to a cleft in the primary binding site of Mpro forming stable hydrogen bond and hydrophobic interactions. We then used multiple µs-time scale molecular dynamics (MD) simulations and machine learning (ML) techniques to elucidate how the bound ligand alters the conformational states accessed by Mpro, involving motions both proximal and distal to the binding site. Together, our results demonstrate how MCULE-5948770040 inhibits Mpro and offers a springboard for further therapeutic design.


Assuntos
COVID-19 , Inibidores de Proteases , Antivirais , Proteases 3C de Coronavírus , Humanos , Simulação de Acoplamento Molecular , Simulação de Dinâmica Molecular , Ácido Orótico/análogos & derivados , Piperazinas , SARS-CoV-2
7.
Rapid Commun Mass Spectrom ; 35(23): e9202, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34545636

RESUMO

RATIONALE: Spatially resolved and accurate quantitation of drug-related compounds in tissue is a much-needed capability in drug discovery research. Here, application of an integrated laser ablation-dropletProbe-mass spectrometry surface sampling system (LADP-MS) is reported, which achieved absolute quantitation of propranolol measured from <500 × 500 µm thin tissue samples. METHODS: Mouse liver and kidney thin tissue sections were coated with parylene C and analyzed for propranolol by a laser ablation/liquid extraction workflow. Non-coated adjacent sections were microdissected for validation and processed using standard bulk tissue extraction protocols. High-performance liquid chromatography with positive ion mode electrospray ionization tandem mass spectrometry was applied to detect the drug and its metabolites. RESULTS: Absolute propranolol concentration in ~500 × 500 µm tissue regions measured by the two methods agreed within ±8% and had a relative standard deviation within ±17%. Quantitation down to ~400 × 400 µm tissue regions was shown, and this resolution was also used for automated mapping of propranolol and phase II hydroxypropranolol glucuronide metabolites in kidney tissue. CONCLUSIONS: This study exemplifies the capabilities of integrated laser ablation-dropletProbe-mass spectrometry (LADP-MS) for high resolution absolute drug quantitation analysis of thin tissue sections. This capability will be valuable for applications needing to quantitatively understand the spatial distribution of small molecules in tissue.


Assuntos
Imagem Molecular/métodos , Preparações Farmacêuticas , Espectrometria de Massas por Ionização por Electrospray/métodos , Animais , Cromatografia Líquida de Alta Pressão/métodos , Desenho de Equipamento , Rim/química , Rim/diagnóstico por imagem , Lasers , Fígado/química , Fígado/diagnóstico por imagem , Masculino , Camundongos , Preparações Farmacêuticas/análise , Preparações Farmacêuticas/metabolismo , Propranolol/análise , Propranolol/farmacocinética , Distribuição Tecidual
8.
Rapid Commun Mass Spectrom ; 35(5): e9010, 2021 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-33232548

RESUMO

RATIONALE: The ability to quantify drugs and metabolites in tissue with sub-mm resolution is a challenging but much needed capability in pharmaceutical research. To fill this void, a novel surface sampling approach combining laser ablation with the commercial dropletProbe automated liquid surface sampling system (LA-dropletProbe) was developed and is presented here. METHODS: Parylene C-coated 200 × 200 µm tissue regions of mouse brain and kidney thin tissue sections were analyzed for propranolol by laser ablation of tissue directly into a preformed liquid junction. Propranolol was detected by high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) in positive electrospray ionization mode. Quantitation was achieved via application of a stable-isotope-labeled internal standard and an external calibration curve. RESULTS: The absolute concentrations of propranolol determined from 200 × 200 µm tissue regions were compared with the propranolol concentrations obtained from 2.3-mm-diameter tissue punches of adjacent, non-coated sections using standard bulk tissue extraction protocols followed by regular HPLC/MS/MS analysis. The average concentration of propranolol in both organs determined by the two employed methods agreed to within ±12%. Furthermore, the relative abundances of phase II hydroxypropranolol glucuronide metabolites were recorded and found to be consistent with previous results. CONCLUSIONS: This work illustrates that depositing a thin layer of parylene C onto thin tissue prior to analysis, which seals the surface and prevents direct liquid extraction of the drug from the tissue, coupled to the novel LA-dropletProbe surface sampling system is a viable approach for sub-mm resolution quantitative drug distribution analysis.


Assuntos
Química Encefálica , Cromatografia Líquida de Alta Pressão/métodos , Terapia a Laser/métodos , Fígado/química , Propranolol/farmacocinética , Espectrometria de Massas em Tandem/métodos , Animais , Encéfalo/metabolismo , Rim/química , Rim/metabolismo , Fígado/metabolismo , Masculino , Camundongos
9.
Anal Bioanal Chem ; 413(10): 2619-2636, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33140126

RESUMO

Mass spectrometry (MS) has become the de facto tool for routine quantitative analysis of biomolecules. MS is increasingly being used to reveal the spatial distribution of proteins, metabolites, and pharmaceuticals in tissue and interest in this area has led to a number of novel spatially resolved MS technologies. Most spatially resolved MS measurements are qualitative in nature due to a myriad of potential biases, such as sample heterogeneity, sampling artifacts, and ionization effects. As applications of spatially resolved MS in the pharmacological and clinical fields increase, demand has become high for quantitative MS imaging and profiling data. As a result, several varied technologies now exist that provide differing levels of spatial and quantitative information. This review provides an overview of MS profiling and imaging technologies that have demonstrated quantitative analysis from tissue. Focus is given on the fundamental processes affecting quantitative analysis in an array of MS imaging and profiling technologies and methods to address these biases.Graphical abstract.


Assuntos
Técnicas Histológicas/métodos , Espectrometria de Massas/métodos , Animais , Desenho de Equipamento , Técnicas Histológicas/instrumentação , Humanos , Espectrometria de Massas/instrumentação , Imagem Molecular/instrumentação , Imagem Molecular/métodos , Análise Serial de Tecidos/instrumentação , Análise Serial de Tecidos/métodos
10.
Anal Bioanal Chem ; 413(28): 6917-6927, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34595558

RESUMO

Quantitative measure of a drug and its associated metabolite(s) with single-cell resolution is often limited by sampling throughput or other compromises that limit broad use. Here, we demonstrate the use of single-cell printing-liquid vortex capture-mass spectrometry (SCP-LVC-MS) to quantitatively measure the intracellular concentrations of amiodarone (AMIO) and its metabolite, N-desethylamiodarone (NDEA), from thousands of single cells across several AMIO incubation concentrations ranging from 0 to 10 µM. Concentrations obtained by SCP-LVC-MS were validated through comparison with average assays and traditional measurement of cells in bulk. Average of SCP-LVC-MS measurements and aggregate vial collection assay the concentrations differed by < 5%. Both AMIO and NDEA had clear log-normal distributions with similar standard deviation of concentrations in the cell population. The mean of both AMIO and NDEA intracellular concentrations were positively correlated with AMIO incubation concentration, increasing from 0.026 to 0.520 and 0.0055 to 0.048 mM for AMIO and NDEA, respectively. The standard deviation of AMIO and NDEA log-normal distribution fits were relatively similar in value across incubation concentrations, 0.15-0.19 log10 (mM), and exhibited a linear trend with respect to each other. The single cell-resolved conversion ratio of AMIO to NDEA increased with decreasing incubation concentration, 7 ± 2%, 18 ± 3%, and 20 ± 7% for 10.0, 1.0, and 0.1 µM AMIO incubation concentrations, respectively. Association with simultaneously measured lipids had several ions with statistically significant difference in intensity but no clear correlations with AMIO intracellular content was observed.


Assuntos
Amiodarona/análogos & derivados , Amiodarona/análise , Espectrometria de Massas/métodos , Análise de Célula Única/métodos , Vasodilatadores/análise , Células Hep G2 , Humanos , Reprodutibilidade dos Testes
11.
Nat Prod Rep ; 36(7): 944-959, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-31112181

RESUMO

Covering: up to 2019The chemistry of nature can be beautiful, inspiring, beneficial and poisonous, depending on perspective. Since the isolation of the first secondary metabolites roughly two centuries ago, much of the chemical research on natural products has been both reductionist and static. Typically, compounds were isolated and characterized from the extract of an entire organism from a single time point. While there could be subtexts to that approach, the general premise has been to determine the chemistry with very little in the way of tools to differentiate spatial and/or temporal changes in secondary metabolite profiles. However, the past decade has seen exponential advances in our ability to observe, measure, and visualize the chemistry of nature in situ. Many of those techniques have been reviewed in this journal, and most are tapping into the power of mass spectrometry to analyze a plethora of sample types. In nearly all of the other techniques used to study chemistry in situ, the element of chromatography has been eliminated, instead using various ionization sources to coax ions of the secondary metabolites directly into the mass spectrometer as a mixture. Much of that science has been driven by the great advances in ambient ionization techniques used with a suite of mass spectrometry platforms, including the alphabet soup from DESI to LAESI to MALDI. This review discusses the one in situ analysis technique that incorporates chromatography, being the droplet-liquid microjunction-surface sampling probe, which is more easily termed "droplet probe". In addition to comparing and contrasting the droplet probe with other techniques, we provide perspective on why scientists, particularly those steeped in natural products chemistry training, may want to include chromatography in in situ analyses. Moreover, we provide justification for droplet sampling, especially for samples with delicate and/or non-uniform topographies. Furthermore, while the droplet probe has been used the most in the analysis of fungal cultures, we digest a variety of other applications, ranging from cyanobacteria, to plant parts, and even delicate documents, such as herbarium specimens.


Assuntos
Produtos Biológicos/química , Cromatografia/métodos , Técnicas Analíticas Microfluídicas , Produtos Biológicos/isolamento & purificação , Técnicas de Cocultura , Cianobactérias/química , Fungos/química , Espectrometria de Massas/métodos , Técnicas Analíticas Microfluídicas/métodos , Plantas/química
12.
Anal Chem ; 91(9): 6118-6126, 2019 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-30955322

RESUMO

We report a method that enables untargeted, high throughput, and quantitative mass spectrometric analysis of single cells from cell suspension without needing additional sample preparation procedures (e.g., molecular tagging) through the combination of single-cell printer technology and liquid vortex capture-mass spectrometry (SCP-LVC-MS). The operating principle behind the SCP-LVC-MS technology is single cell isolation via small droplet piezoelectric ejection followed by capture of the droplet into an LVC-MS sampling probe. Once exposed to an appropriate solvent, the cell is lysed, extracted, and analyzed by MS. The SCP-LVC-MS approach was validated by measuring the lipid composition of microalgae, Chlamydomonas reinhardtii (ChRe) and Euglena gracilis (EuGr), and HeLa cells in their native growth media. Numerous diacylglyceryltrimethylhomo-Ser (DGTS), phosphatidylcholine (PC), monogalactosyldiacylglycerol (MGDG), and digalactosyldiacylglycerol (DGDG) lipids were observed in single cells. Continuous solvent flow ensures that cells are analyzed rapidly, and no signal carryover between cells is observed. ChRe and EuGr microalgae mixed together in the same solution were differentiated cell-by-cell in real-time based on differences between levels of diacylglyceryltrimethylhomo-Ser (DGTS) and phosphatidylcholine (PC) lipids measured in each cell. Several DGTS lipids present in ChRe were quantified with single-cell resolution by normalizing to a DGTS(32:0) internal standard added to the LVC probe solvent during analysis. Quantitative peak areas were validated by comparing to bulk lipid extracts. Lastly, peak area distributions comprised of hundreds of cells were compared for ChRe after 5 days of nitrogen-limited and normal growth conditions, which show clear differences and the ability to resolve cellular population differences with single-cell resolution.


Assuntos
Microdissecção e Captura a Laser , Lipídeos/análise , Análise de Célula Única , Chlamydomonas reinhardtii/química , Chlamydomonas reinhardtii/citologia , Chlamydomonas reinhardtii/crescimento & desenvolvimento , Euglena gracilis/química , Euglena gracilis/citologia , Euglena gracilis/crescimento & desenvolvimento , Células HeLa , Humanos , Espectrometria de Massas , Tamanho da Partícula , Propriedades de Superfície
13.
Rapid Commun Mass Spectrom ; 32(5): 414-422, 2018 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-29297944

RESUMO

RATIONALE: Laser microdissection-liquid vortex capture/electrospray ionization mass spectrometry (LMD-LVC/ESI-MS) has potential for on-line classification of tissue but an investigation into what analytical conditions provide best spectral differentiation has not been conducted. The effects of solvent, ionization polarity, and spectral acquisition parameters on differentiation of mouse brain tissue regions are described. METHODS: Individual 40 × 40 µm microdissections from cortex, white, grey, granular, and nucleus regions of mouse brain tissue were analyzed using different capture/ESI solvents, in positive and negative ion mode ESI, using time-of-flight (TOF)-MS and sequential window acquisitions of all theoretical spectra (SWATH)-MS (a permutation of tandem-MS), and combinations thereof. Principal component analysis-linear discriminant analysis (PCA-LDA), applied to each mass spectral dataset, was used to determine the accuracy of differentiation of mouse brain tissue regions. RESULTS: Mass spectral differences associated with capture/ESI solvent composition manifested as altered relative distributions of ions rather than the presence or absence of unique ions. In negative ion mode ESI, 80/20 (v/v) methanol/water yielded spectra with low signal/noise ratios relative to other solvents. PCA-LDA models acquired using 90/10 (v/v) methanol/chloroform differentiated tissue regions with 100% accuracy while data collected using methanol misclassified some samples. The combination of SWATH-MS and TOF-MS data improved differentiation accuracy. CONCLUSIONS: Combined TOF-MS and SWATH-MS data differentiated white, grey, granular, and nucleus mouse tissue regions with greater accuracy than when solely using TOF-MS data. Using 90/10 (v/v) methanol/chloroform, tissue regions were perfectly differentiated. These results will guide future studies looking to utilize the potential of LMD-LVC/ESI-MS for tissue and disease differentiation.

14.
Anal Chem ; 89(5): 3036-3042, 2017 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-28218833

RESUMO

The use of atomic force microscopy controlled nanothermal analysis probes for reproducible spatially resolved thermally assisted sampling of micrometer-sized areas (ca. 11 × 17 µm wide × 2.4 µm deep) from relatively low number-average molecular weight (Mn < 3000) polydisperse thin films of poly(2-vinylpyridine) (P2VP) is presented. Following sampling, the nanothermal analysis probes were moved up from the surface and the probe temperature ramped to liberate the sampled materials into the gas phase for atmospheric pressure chemical ionization and mass spectrometric analysis. The procedure and mechanism for material pickup, the sampling reproducibility and sampling size are discussed, and the oligomer distribution information available from slow temperature ramps versus ballistic temperature jumps is presented. For the Mn = 970 P2VP, the Mn and polydispersity index determined from the mass spectrometric data were in line with both the label values from the sample supplier and the value calculated from the simple infusion of a solution of polymer into the commercial atmospheric pressure chemical ionization source on this mass spectrometer. With a P2VP sample of higher Mn (Mn = 2070 and 2970), intact oligomers were still observed (as high as m/z 2793 corresponding to the 26-mer), but a significant abundance of thermolysis products were also observed. In addition, the capability for confident identification of the individual oligomers by slowly ramping the probe temperature and collecting data-dependent tandem mass spectra was also demonstrated. The material type limits to the current sampling and analysis approach as well as possible improvements in nanothermal analysis probe design to enable smaller area sampling and to enable controlled temperature ramps beyond the present upper limit of about 415 °C are also discussed.

15.
Anal Chem ; 89(22): 12578-12586, 2017 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-29112402

RESUMO

The aim of this work was to demonstrate and to evaluate the analytical performance of a combined falling drop/open port sampling interface (OPSI) system as a simple noncontact, no-carryover, automated system for flow injection analysis with mass spectrometry. The falling sample drops were introduced into the OPSI using a widely available autosampler platform utilizing low cost disposable pipet tips and conventional disposable microtiter well plates. The volume of the drops that fell onto the OPSI was in the 7-15 µL range with an injected sample volume of several hundred nanoliters. Sample drop height, positioning of the internal capillary on the sampling end of the probe, and carrier solvent flow rate were optimized for maximum signal. Sample throughput, signal reproducibility, matrix effects, and quantitative analysis capability of the system were established using the drug molecule propranolol and its isotope labeled internal standard in water, unprocessed river water and two commercially available buffer matrices. A sample-to-sample throughput of ∼45 s with a ∼4.5 s base-to-base flow injection peak profile was obtained in these experiments. In addition, quantitation with minimally processed rat plasma samples was demonstrated with three different statin drugs (atorvastatin, rosuvastatin, and fluvastatin). Direct characterization capability of unprocessed samples was demonstrated by the analysis of neat vegetable oils. Employing the autosampler system for spatially resolved liquid extraction surface sampling exemplified by the analysis of propranolol and its hydroxypropranolol glucuronide phase II metabolites from a rat thin tissue section was also illustrated.

16.
Rapid Commun Mass Spectrom ; 31(3): 281-291, 2017 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-27862458

RESUMO

RATIONALE: An "Open Access"-like mass spectrometric platform to fully utilize the simplicity of the manual open port sampling interface for rapid characterization of unprocessed samples by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The in-house developed integrated software with a simple, small and relatively low-cost mass spectrometry system introduced here fills this void. METHODS: Software was developed to operate the mass spectrometer, to collect and process mass spectrometric data files, to build a database and to classify samples using such a database. These tasks were accomplished via the vendor-provided software libraries. Sample classification based on spectral comparison utilized the spectral contrast angle method. RESULTS: Using the developed software platform near real-time sample classification is exemplified using a series of commercially available blue ink rollerball pens and vegetable oils. In the case of the inks, full scan positive and negative ion ESI mass spectra were both used for database generation and sample classification. For the vegetable oils, full scan positive ion mode APCI mass spectra were recorded. The overall accuracy of the employed spectral contrast angle statistical model was 95.3% and 98% in case of the inks and oils, respectively, using leave-one-out cross-validation. CONCLUSIONS: This work illustrates that an open port sampling interface/mass spectrometer combination, with appropriate instrument control and data processing software, is a viable direct liquid extraction sampling and analysis system suitable for the non-expert user and near real-time sample classification via database matching. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA.

17.
Rapid Commun Mass Spectrom ; 31(14): 1204-1210, 2017 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-28493365

RESUMO

RATIONALE: As the spatial resolution of mass spectrometry imaging technologies has begun to reach into the nanometer regime, finding readily available or easily made resolution reference materials has become particularly challenging for molecular imaging purposes. This paper describes the fabrication, characterization and use of vertical line array polymeric spatial resolution test patterns for nano-thermal analysis/atomic force microscopy/mass spectrometry chemical imaging. METHODS: Test patterns of varied line width (0.7 or 1.0 µm) and spacing (0.7 or 1.0 µm) were created in an ~1-µm-thick poly(methyl methacrylate) thin film using electron beam lithography. The patterns were characterized by scanning electron microscopy, energy-dispersive X-ray spectroscopy, atomic force microscopy topography and nano-thermal analysis/mass spectrometry imaging. RESULTS: The efficacy of these polymeric test patterns for the advancement of chemical imaging techniques was illustrated by their use to judge the spatial resolution improvement achieved by heating the ionization interface of the current instrument platform. The spatial resolution of the mass spectral chemical images was estimated to be 1.4 µm, based on the ability to statistically distinguish 0.7-µm-wide lines separated by 0.7-µm-wide spacings in those images when the interface cross was heated to 200°C. CONCLUSIONS: This work illustrates that e-beam lithography is a viable method to create spatial resolution test patterns in a thin film of high molecular weight polymer to allow unbiased judgment of intra-laboratory advancement and/or inter-laboratory comparison of instrument advances in nano-thermal analysis/atomic force microscopy/mass spectrometry chemical imaging. Published in 2017. This article is a U.S. Government work and is in the public domain in the USA.

19.
Anal Chem ; 88(5): 2864-70, 2016 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-26890087

RESUMO

In this paper, the use of a hybrid atomic force microscopy/infrared spectroscopy/mass spectrometry imaging platform was demonstrated for the acquisition and correlation of nanoscale sample surface topography and chemical images based on infrared spectroscopy and mass spectrometry. The infrared chemical imaging component of the system utilized photothermal expansion of the sample at the tip of the atomic force microscopy probe recorded at infrared wave numbers specific to the different surface constituents. The mass spectrometry-based chemical imaging component of the system utilized nanothermal analysis probes for thermolytic surface sampling followed by atmospheric pressure chemical ionization of the gas phase species produced with subsequent mass analysis. The basic instrumental setup, operation, and image correlation procedures are discussed, and the multimodal imaging capability and utility are demonstrated using a phase separated poly(2-vinylpyridine)/poly(methyl methacrylate) polymer thin film. The topography and both the infrared and mass spectral chemical images showed that the valley regions of the thin film surface were comprised primarily of poly(2-vinylpyridine) and hill or plateau regions were primarily poly(methyl methacrylate). The spatial resolution of the mass spectral chemical images was estimated to be 1.6 µm based on the ability to distinguish surface features in those images that were also observed in the topography and infrared images of the same surface.

20.
Anal Chem ; 88(11): 6026-34, 2016 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-27214103

RESUMO

Spatial resolved quantitation of chemical species in thin tissue sections by mass spectrometric methods has been constrained by the need for matrix-matched standards or other arduous calibration protocols and procedures to mitigate matrix effects (e.g., spatially varying ionization suppression). Reported here is the use of laser "cut and drop" sampling with a laser microdissection-liquid vortex capture electrospray ionization tandem mass spectrometry (LMD-LVC/ESI-MS/MS) system for online and absolute quantitation of propranolol in mouse brain, kidney, and liver thin tissue sections of mice administered with the drug at a 7.5 mg/kg dose, intravenously. In this procedure either 20 µm × 20 µm or 40 µm × 40 µm tissue microdissections were cut and dropped into the flowing solvent of the capture probe. During transport to the ESI source drug related material was completely extracted from the tissue into the solvent, which contained a known concentration of propranolol-d7 as an internal standard. This allowed absolute quantitation to be achieved with an external calibration curve generated from standards containing the same fixed concentration of propranolol-d7 and varied concentrations of propranolol. Average propranolol concentrations determined with the laser "cut and drop" sampling method closely agreed with concentration values obtained from 2.3 mm diameter tissue punches from serial sections that were extracted and quantified by HPLC/ESI-MS/MS measurements. In addition, the relative abundance of hydroxypropranolol glucuronide metabolites were recorded and found to be consistent with previous findings.


Assuntos
Química Encefálica , Internet , Rim/química , Microdissecção e Captura a Laser , Fígado/química , Propranolol/análise , Animais , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas , Camundongos , Estrutura Molecular
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa