Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 28(1): 143-150, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28695359

RESUMO

OBJECTIVE: To assess the performance of hybrid (HIR) and model-based iterative reconstruction (MIR) in patients with urolithiasis at reduced-dose computed tomography (CT). METHODS: Twenty patients scheduled for unenhanced abdominal CT for follow-up of urolithiasis were prospectively included. Routine dose acquisition was followed by three low-dose acquisitions at 40%, 60% and 80% reduced doses. All images were reconstructed with filtered back projection (FBP), HIR and MIR. Urolithiasis detection rates, gall bladder, appendix and rectosigmoid evaluation and overall subjective image quality were evaluated by two observers. RESULTS: 74 stones were present in 17 patients. Half the stones were not detected on FBP at the lowest dose level, but this improved with MIR to a sensitivity of 100%. HIR resulted in a slight decrease in sensitivity at the lowest dose to 72%, but outperformed FBP. Evaluation of other structures with HIR at 40% and with MIR at 60% dose reductions was comparable to FBP at routine dose, but 80% dose reduction resulted in non-evaluable images. CONCLUSIONS: CT radiation dose for urolithiasis detection can be safely reduced by 40 (HIR)-60 (MIR) % without affecting assessment of urolithiasis, possible extra-urinary tract pathology or overall image quality. KEY POINTS: • Iterative reconstruction can be used to substantially lower the radiation dose. • This allows for radiation reduction without affecting sensitivity of stone detection. • Possible extra-urinary tract pathology evaluation is feasible at 40-60% reduced dose.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Urolitíase/diagnóstico por imagem , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Sistema Urinário/diagnóstico por imagem
2.
Eur Radiol ; 27(9): 3677-3686, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28124106

RESUMO

OBJECTIVES: The aim of this study was to evaluate the feasibility and accuracy of dual-layer spectral detector CT (SDCT) for the quantification of clinically encountered gadolinium concentrations. METHODS: The cardiac chamber of an anthropomorphic thoracic phantom was equipped with 14 tubular inserts containing different gadolinium concentrations, ranging from 0 to 26.3 mg/mL (0.0, 0.1, 0.2, 0.4, 0.5, 1.0, 2.0, 3.0, 4.0, 5.1, 10.6, 15.7, 20.7 and 26.3 mg/mL). Images were acquired using a novel 64-detector row SDCT system at 120 and 140 kVp. Acquisitions were repeated five times to assess reproducibility. Regions of interest (ROIs) were drawn on three slices per insert. A spectral plot was extracted for every ROI and mean attenuation profiles were fitted to known attenuation profiles of water and pure gadolinium using in-house-developed software to calculate gadolinium concentrations. RESULTS: At both 120 and 140 kVp, excellent correlations between scan repetitions and true and measured gadolinium concentrations were found (R > 0.99, P < 0.001; ICCs > 0.99, CI 0.99-1.00). Relative mean measurement errors stayed below 10% down to 2.0 mg/mL true gadolinium concentration at 120 kVp and below 5% down to 1.0 mg/mL true gadolinium concentration at 140 kVp. CONCLUSION: SDCT allows for accurate quantification of gadolinium at both 120 and 140 kVp. Lowest measurement errors were found for 140 kVp acquisitions. KEY POINTS: • Gadolinium quantification may be useful in patients with contraindication to iodine. • Dual-layer spectral detector CT allows for overall accurate quantification of gadolinium. • Interscan variability of gadolinium quantification using SDCT material decomposition is excellent.


Assuntos
Gadolínio/análise , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Estudos de Viabilidade , Coração , Reprodutibilidade dos Testes
3.
Eur Radiol ; 27(10): 4351-4359, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28374079

RESUMO

OBJECTIVES: To investigate the accuracy of bone mineral density (BMD) quantification using dual-layer spectral detector CT (SDCT) at various scan protocols. METHODS: Two validated anthropomorphic phantoms containing inserts of 50-200 mg/cm3 calcium hydroxyapatite (HA) were scanned using a 64-slice SDCT scanner at various acquisition protocols (120 and 140 kVp, and 50, 100 and 200 mAs). Regions of interest (ROIs) were placed in each insert and mean attenuation profiles at monochromatic energy levels (90-200 keV) were constructed. These profiles were fitted to attenuation profiles of pure HA and water to calculate HA concentrations. For comparison, one phantom was scanned using dual energy X-ray absorptiometry (DXA). RESULTS: At both 120 and 140 kVp, excellent correlations (R = 0.97, P < 0.001) were found between true and measured HA concentrations. Mean error for all measurements at 120 kVp was -5.6 ± 5.7 mg/cm3 (-3.6 ± 3.2%) and at 140 kVp -2.4 ± 3.7 mg/cm3 (-0.8 ± 2.8%). Mean measurement errors were smaller than 6% for all acquisition protocols. Strong linear correlations (R2 ≥ 0.970, P < 0.001) with DXA were found. CONCLUSIONS: SDCT allows for accurate BMD quantification and potentially opens up the possibility for osteoporosis evaluation and opportunistic screening in patients undergoing SDCT for other clinical indications. However, patient studies are needed to extend and translate our findings. KEY POINTS: • Dual-layer spectral detector CT allows for accurate bone mineral density quantification. • BMD measurements on SDCT are strongly linearly correlated to DXA. • SDCT, acquired for several indications, may allow for evaluation of osteoporosis. • This potentially opens up the possibility for opportunistic osteoporosis screening.


Assuntos
Densidade Óssea , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Absorciometria de Fóton , Humanos , Osteoporose/diagnóstico por imagem
4.
J Comput Assist Tomogr ; 41(1): 148-155, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27560017

RESUMO

OBJECTIVE: This study aimed to determine the lowest radiation dose and iterative reconstruction level(s) at which computed tomography (CT)-based quantification of aortic valve calcification (AVC) and thoracic aortic calcification (TAC) is still feasible. METHODS: Twenty-eight patients underwent a cardiac CT and 20 patients a chest CT at 4 different dose levels (routine dose and approximately 40%, 60%, and 80% reduced dose). Data were reconstructed with filtered back projection, 3 iDose levels, and 3 iterative model-based reconstruction levels. Two observers scored subjective image quality. The AVC and TAC were quantified using mass and compared to the reference scan (routine dose reconstructed with filtered back projection). RESULTS: In cardiac CT at 0.35 mSv (60% reduced), all scans reconstructed with iDose (all levels) were diagnostic, calcification detection errors occurred in only 1 patient, and there were no significant differences in mass scores compared to the reference scan. Similar results were found for chest CT at 0.48 mSv (75% reduced) with iDose levels 4 and 6 and iterative model reconstruction levels 1 and 2. CONCLUSIONS: Iterative reconstruction enables AVC and TAC quantification on CT at submillisievert dose.


Assuntos
Aorta Torácica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Exposição à Radiação/prevenção & controle , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/métodos , Calcificação Vascular/diagnóstico por imagem , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Exposição à Radiação/análise , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
J Comput Assist Tomogr ; 40(4): 578-83, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27096400

RESUMO

OBJECTIVE: The aim of the study was to determine the effects of dose reduction and iterative reconstruction (IR) on pulmonary nodule volumetry. METHODS: In this prospective study, 25 patients scheduled for follow-up of pulmonary nodules were included. Computed tomography acquisitions were acquired at 4 dose levels with a median of 2.1, 1.2, 0.8, and 0.6 mSv. Data were reconstructed with filtered back projection (FBP), hybrid IR, and model-based IR. Volumetry was performed using semiautomatic software. RESULTS: At the highest dose level, more than 91% (34/37) of the nodules could be segmented, and at the lowest dose level, this was more than 83%. Thirty-three nodules were included for further analysis. Filtered back projection and hybrid IR did not lead to significant differences, whereas model-based IR resulted in lower volume measurements with a maximum difference of -11% compared with FBP at routine dose. CONCLUSIONS: Pulmonary nodule volumetry can be accurately performed at a submillisievert dose with both FBP and hybrid IR.


Assuntos
Imageamento Tridimensional/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Modelos Estatísticos , Doses de Radiação , Proteção Radiológica/métodos , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Carga Tumoral
6.
AJR Am J Roentgenol ; 204(3): 645-53, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25714298

RESUMO

OBJECTIVE. Radiation exposure from CT examinations should be reduced to a minimum in children. Iterative reconstruction (IR) is a method to reduce image noise that can be used to improve CT image quality, thereby allowing radiation dose reduction. This article reviews the use of hybrid and model-based IRs in pediatric CT and discusses the possibilities, advantages, and disadvantages of IR in pediatric CT and the importance of radiation dose reduction for CT of children. CONCLUSION. IR is a promising and potentially highly valuable technique that can be used to substantially reduce the amount of radiation in pediatric imaging. Future research should determine the maximum achievable radiation dose reduction in pediatric CT that is possible without a loss of diagnostic image quality.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Modelos Teóricos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Criança , Humanos
7.
Radiology ; 273(3): 695-702, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25153157

RESUMO

PURPOSE: To determine the intervendor variability of Agatston scoring determined with state-of-the-art computed tomographic (CT) systems from the four major vendors in an ex vivo setup and to simulate the subsequent effects on cardiovascular risk reclassification in a large population-based cohort. MATERIALS AND METHODS: Research ethics board approval was not necessary because cadaveric hearts from individuals who donated their bodies to science were used. Agatston scores obtained with CT scanners from four different vendors were compared. Fifteen ex vivo human hearts were placed in a phantom resembling an average human adult. Hearts were scanned at equal radiation dose settings for the systems of all four vendors. Agatston scores were quantified semiautomatically with software used clinically. The ex vivo Agatston scores were used to simulate the effects of different CT scanners on reclassification of 432 individuals aged 55 years or older from a population-based study who were at intermediate cardiovascular risk based on Framingham risk scores. The Friedman test was used to evaluate overall differences, and post hoc analyses were performed by using the Wilcoxon signed-rank test with Bonferroni correction. RESULTS: Agatston scores differed substantially when CT scanners from different vendors were used, with median Agatston scores ranging from 332 (interquartile range, 114-1135) to 469 (interquartile range, 183-1381; P < .05). Simulation showed that these differences resulted in a change in cardiovascular risk classification in 0.5%-6.5% of individuals at intermediate risk when a CT scanner from a different vendor was used. CONCLUSION: Among individuals at intermediate cardiovascular risk, state-of the-art CT scanners made by different vendors produced substantially different Agatston scores, which can result in reclassification of patients to the high- or low-risk categories in up to 6.5% of cases.


Assuntos
Calcinose/classificação , Calcinose/diagnóstico por imagem , Doença das Coronárias/classificação , Doença das Coronárias/diagnóstico por imagem , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/instrumentação , Cadáver , Humanos , Imagens de Fantasmas , Medição de Risco , Fatores de Risco
8.
Eur Radiol ; 24(9): 2201-12, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24889996

RESUMO

OBJECTIVES: To analyse the effects of radiation dose reduction and iterative reconstruction (IR) algorithms on coronary calcium scoring (CCS). METHODS: Fifteen ex vivo human hearts were examined in an anthropomorphic chest phantom using computed tomography (CT) systems from four vendors and examined at four dose levels using unenhanced prospectively ECG-triggered protocols. Tube voltage was 120 kV and tube current differed between protocols. CT data were reconstructed with filtered back projection (FBP) and reduced dose CT data with IR. CCS was quantified with Agatston scores, calcification mass and calcification volume. Differences were analysed with the Friedman test. RESULTS: Fourteen hearts showed coronary calcifications. Dose reduction with FBP did not significantly change Agatston scores, calcification volumes and calcification masses (P > 0.05). Maximum differences in Agatston scores were 76, 26, 51 and 161 units, in calcification volume 97, 27, 42 and 162 mm(3), and in calcification mass 23, 23, 20 and 48 mg, respectively. IR resulted in a trend towards lower Agatston scores and calcification volumes with significant differences for one vendor (P < 0.05). Median relative differences between reference FBP and reduced dose IR for Agatston scores remained within 2.0-4.6%, 1.0-5.3%, 1.2-7.7% and 2.6-4.5%, for calcification volumes within 2.4-3.9%, 1.0-5.6%, 1.1-6.4% and 3.7-4.7%, for calcification masses within 1.9-4.1%, 0.9-7.8%, 2.9-4.7% and 2.5-3.9%, respectively. IR resulted in increased, decreased or similar calcification masses. CONCLUSIONS: CCS derived from standard FBP acquisitions was not affected by radiation dose reductions up to 80%. IR resulted in a trend towards lower Agatston scores and calcification volumes. KEY POINTS: In this ex vivo study, radiation dose could be reduced by 80% for coronary calcium scoring. Iterative reconstruction resulted in a trend towards lower Agatston scores and calcification volumes. Caution should be taken for coronary calcium scoring with iterative reconstruction.


Assuntos
Algoritmos , Calcinose/diagnóstico por imagem , Cálcio/análise , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/química , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Cadáver , Calcinose/metabolismo , Doença da Artéria Coronariana/metabolismo , Humanos , Imagens de Fantasmas , Doses de Radiação , Reprodutibilidade dos Testes
9.
J Comput Assist Tomogr ; 38(6): 815-23, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24983438

RESUMO

OBJECTIVE: We evaluated the effects of hybrid and model-based iterative reconstruction (IR) algorithms from different vendors at multiple radiation dose levels on image quality of chest phantom scans. METHODS: A chest phantom was scanned on state-of-the-art computed tomography scanners from 4 vendors at 4 dose levels (4.1 mGy, 3.0 mGy, 1.9 mGy, and 0.8 mGy). All data were reconstructed with filtered back projection (FBP) and reduced-dose data also with IR (iDose4, Adaptive Iterative Dose Reduction 3D, Adaptive Statistical Iterative Reconstruction, Sinogram-Affirmed Iterative Reconstruction, prototype Iterative Model Reconstruction, and Veo). Computed tomography numbers and noise were measured in the spine and lungs. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were calculated and differences were analyzed with the Friedman test. RESULTS: For all vendors, radiation dose reduction with FBP resulted in significantly increased noise levels (≤148%) as well as decreased SNR (≤57%) and CNR (≤58%) (P < 0.001). Conversely, IR resulted in decreased noise levels (≤48%) as well as increased SNR (≤94%) and CNR (≤94%). The SNRs and CNRs of the model-based algorithms at 80% reduced dose were similar to reference-dose FBP. CONCLUSIONS: Hybrid IR algorithms have the potential to reduce radiation dose with 27% to 54% and model-based IR algorithms with up to 80%.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/normas , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador/instrumentação , Doses de Radiação , Tomografia Computadorizada por Raios X/instrumentação
10.
Eur Radiol ; 23(4): 968-74, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23064676

RESUMO

OBJECTIVES: To compare native aortic (AV) and mitral valve (MV) image quality on limited-dose retrospectively ECG-gated CTA of the thoracoabdominal aorta reconstructed with iterative reconstruction (IR) and filtered back projection (FBP). METHODS: Fifty patients underwent routine care retrospectively ECG-gated thoracoabdominal limited-dose 256-slice CTA. At 30 % (systole) and 75 % (diastole) of the R-R interval AV and MV were reconstructed using FBP and IR. Objective image quality [density and noise (SD of density measurement)] was measured. Two independent observers scored subjective valve image quality using four-point Likert scales. RESULTS: IR significantly decreased image noise, but did not alter the aorta and interventricular septum density. Interobserver variability was moderate to good. Valve image quality was scored at least moderate in most cases. IR scored one or two Likert scale points higher than FBP in 10 (first observer) and 27 (second observer) scores. Conversely, IR scored one Likert scale point lower than FBP in 1 (first observer) and 4 (second observer) scores. CONCLUSIONS: Limited-dose retrospectively ECG-gated thoracoabdominal CTA enables moderate to excellent evaluation of AV and MV in most patients, in addition to the primary diagnostic question. Image quality is further improved by IR.


Assuntos
Valva Aórtica/diagnóstico por imagem , Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia Coronária/métodos , Valva Mitral/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Masculino , Radiografia Abdominal/métodos , Radiografia Torácica/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
11.
Eur Radiol ; 23(6): 1623-31, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23314600

RESUMO

OBJECTIVES: To explain the technical principles of and differences between commercially available iterative reconstruction (IR) algorithms for computed tomography (CT) in non-mathematical terms for radiologists and clinicians. METHODS: Technical details of the different proprietary IR techniques were distilled from available scientific articles and manufacturers' white papers and were verified by the manufacturers. Clinical results were obtained from a literature search spanning January 2006 to January 2012, including only original research papers concerning IR for CT. RESULTS: IR for CT iteratively reduces noise and artefacts in either image space or raw data, or both. Reported dose reductions ranged from 23 % to 76 % compared to locally used default filtered back-projection (FBP) settings, with similar noise, artefacts, subjective, and objective image quality. CONCLUSION: IR has the potential to allow reducing the radiation dose while preserving image quality. Disadvantages of IR include blotchy image appearance and longer computational time. Future studies need to address differences between IR algorithms for clinical low-dose CT. KEY POINTS: • Iterative reconstruction technology for CT is presented in non-mathematical terms. • IR reduces noise and artefacts compared to filtered back-projection. • IR can improve image quality in routine-dose CT and lower the radiation dose. • IR's disadvantages include longer computation and blotchy appearance of some images.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Artefatos , Humanos , Imageamento Tridimensional , Imagens de Fantasmas , Doses de Radiação , Radiologia/métodos , Reprodutibilidade dos Testes
12.
Eur Radiol ; 23(6): 1632-42, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23322411

RESUMO

OBJECTIVES: To present the results of a systematic literature search aimed at determining to what extent the radiation dose can be reduced with iterative reconstruction (IR) for cardiopulmonary and body imaging with computed tomography (CT) in the clinical setting and what the effects on image quality are with IR versus filtered back-projection (FBP) and to provide recommendations for future research on IR. METHODS: We searched Medline and Embase from January 2006 to January 2012 and included original research papers concerning IR for CT. RESULTS: The systematic search yielded 380 articles. Forty-nine relevant studies were included. These studies concerned: the chest(n = 26), abdomen(n = 16), both chest and abdomen(n = 1), head(n = 4), spine(n = 1), and no specific area (n = 1). IR reduced noise and artefacts, and it improved subjective and objective image quality compared to FBP at the same dose. Conversely, low-dose IR and normal-dose FBP showed similar noise, artefacts, and subjective and objective image quality. Reported dose reductions ranged from 23 to 76 % compared to locally used default FBP settings. However, IR has not yet been investigated for ultra-low-dose acquisitions with clinical diagnosis and accuracy as endpoints. CONCLUSION: Benefits of IR include improved subjective and objective image quality as well as radiation dose reduction while preserving image quality. Future studies need to address the value of IR in ultra-low-dose CT with clinically relevant endpoints. KEY POINTS: • Iterative reconstruction improves image quality of CT images at equal acquisition parameters. • IR preserves image quality compared to normal-dose filtered back-projection. • The reduced radiation dose made possible by IR is advantageous for patients. • IR has not yet been investigated with clinical diagnosis and accuracy as endpoints.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Artefatos , Meios de Contraste/farmacologia , Humanos , Reprodutibilidade dos Testes , Espalhamento de Radiação
13.
Eur J Radiol ; 146: 110080, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34875474

RESUMO

PURPOSE: Computed tomography (CT) might be a good diagnostic test to accurately quantify calcium in vascular beds but there are multiple factors influencing the quantification. The aim of this study was to investigate the influence of different computed tomography protocol settings in the quantification of calcium in the lower extremities using modified Agatston and volume scores. METHODS: Fresh-frozen human legs were scanned at different tube current protocols and reconstructed at different slice thickness. Two different iterative reconstruction protocols for conventional CT images were compared. Calcium was manually scored using modified Agatston and volume scores. Outcomes were statistically analyzed using Wilcoxon signed-rank tests and mean absolute and relative differences were plotted in Bland-Altman plots. RESULTS: Of the 20 legs, 16 had CT detectable calcifications. Differences between thick and thin slice reconstruction protocols were 129 Agatston units and 125% for Agatston and 78.4 mm3 and 57.8% for volume (all p ≤ 0.001). No significant differences were found between low and high tube current protocols. Differences between iDose4 and IMR reconstruction protocols for modified Agatston were 34.2 Agatston units and 17.7% and the volume score 33.5 mm3 and 21.2% (all p ≤ 0.001). CONCLUSIONS: Slice thickness reconstruction and reconstruction method protocols influenced the modified Agatston and volume scores in leg arteries, but tube current and different observers did not have an effect. This data emphasizes the need for standardized quantification of leg artery calcifications. Possible implications are in the development of a more universal quantification method, independent of the type of scan and vasculature.


Assuntos
Cálcio , Doença da Artéria Coronariana , Algoritmos , Cadáver , Cálcio/análise , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Perna (Membro)/diagnóstico por imagem , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X
14.
Med Phys ; 45(7): 3031-3042, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29749624

RESUMO

PURPOSE: Spectral CT using a dual layer detector offers the possibility of retrospectively introducing spectral information to conventional CT images. In theory, the dual-layer technology should not come with a dose or image quality penalty for conventional images. In this study, we evaluate the influence of a dual-layer detector (IQon Spectral CT, Philips Healthcare) on the image quality of conventional CT images, by comparing these images with those of a conventional but otherwise technically comparable single-layer CT scanner (Brilliance iCT, Philips Healthcare), by means of phantom experiments. METHODS: For both CT scanners, conventional CT images were acquired using four adult scanning protocols: (a) body helical, (b) body axial, (c) head helical, and (d) head axial. A CATPHAN 600 phantom was scanned to conduct an assessment of image quality metrics at equivalent (CTDI) dose levels. Noise was characterized by means of noise power spectra (NPS) and standard deviation (SD) of a uniform region, and spatial resolution was evaluated with modulation transfer functions (MTF) of a tungsten wire. In addition, contrast-to-noise ratio (CNR), image uniformity, CT number linearity, slice thickness, slice spacing, and spatial linearity were measured and evaluated. Additional measurements of CNR, resolution and noise were performed in two larger phantoms. RESULTS: The resolution levels at 50%, 10%, and 5% MTF of the iCT and IQon showed small, but significant differences up to 0.25 lp/cm for body scans, and up to 0.2 lp/cm for head scans in favor of the IQon. The iCT and IQon showed perfect CT linearity for body scans, but for head scans both scanners showed an underestimation of the CT numbers of materials with a high opacity. Slice thickness was slightly overestimated for both scanners. Slice spacing was comparable and reconstructed correctly. In addition, spatial linearity was excellent for both scanners, with a maximum error of 0.11 mm. CNR was higher on the IQon compared to the iCT for both normal and larger phantoms with differences up to 0.51. Spatial resolution did not change with phantom size, but noise levels increased significantly. For head scans, IQon had a noise level that was significantly lower than the iCT, on the other hand IQon showed noise levels significantly higher than the iCT for body scans. Still, these differences were well within the specified range of performance of iCT scanners. CONCLUSIONS: At equivalent dose levels, this study showed similar quality of conventional images acquired on iCT and IQon for medium-sized phantoms and slightly degraded image quality for (very) large phantoms at lower tube voltages on the IQon. Accordingly, it may be concluded that the introduction of a dual-layer detector neither compromises image quality of conventional images nor increases radiation dose for normal-sized patients, and slightly degrades dose efficiency for large patients at 120 kVp and lower tube voltages.


Assuntos
Imagens de Fantasmas , Tomografia Computadorizada por Raios X/instrumentação , Processamento de Imagem Assistida por Computador , Controle de Qualidade , Doses de Radiação , Razão Sinal-Ruído
15.
Int J Cardiovasc Imaging ; 34(8): 1265-1275, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29516228

RESUMO

We investigated the feasibility and extent to which iodine concentration can be reduced in computed tomography angiography imaging of the aorta and coronary arteries using low tube voltage and virtual monochromatic imaging of 3 major dual-energy CT (DECT) vendors. A circulation phantom was imaged with dual source CT (DSCT), gemstone spectral imaging (GSI) and dual-layer spectral detector CT (SDCT). For each scanner, a reference scan was acquired at 120 kVp using routine iodine concentration (300 mg I/ml). Subsequently, scans were acquired at lowest possible tube potential (70, 80, 80 kVp, respectively), and DECT-mode (80/150Sn, 80/140 and 120 kVp, respectively) in arterial phase after administration of iodine (300, 240, 180, 120, 60, 30 mg I/ml). Objective image quality was evaluated using attenuation, CNR and dose corrected CNR (DCCNR) measured in the aorta and left main coronary artery. Average DCCNR at reference was 227.0, 39.7 and 60.2 for DSCT, GSI and SDCT. Maximum iodine concentration reduction without loss of DCCNR was feasible down to 180 mg I/ml (40% reduced) for DSCT (DCCNR 467.1) and GSI (DCCNR 46.1) using conventional CT low kVp, and 120 mg I/ml (60% reduced) for SDCT (DCCNR 171.5) using DECT mode. Low kVp scanning and DECT allows for 40-60% iodine reduction without loss in image quality compared to reference. Optimal scan protocol and to which extent varies per vendor. Further patient studies are needed to extend and translate our findings to clinical practice.


Assuntos
Aorta/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Vasos Coronários/diagnóstico por imagem , Iohexol/análogos & derivados , Imagens de Fantasmas , Angiografia por Tomografia Computadorizada/normas , Estudos de Viabilidade , Humanos , Processamento de Imagem Assistida por Computador , Iohexol/administração & dosagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas
16.
Eur Radiol Exp ; 2(1): 30, 2018 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-30402740

RESUMO

BACKGROUND: Computed tomography (CT) emphysema quantification is affected by both radiation dose (i.e. image noise) and reconstruction technique. At reduced dose, filtered back projection (FBP) results in an overestimation of the amount of emphysema due to higher noise levels, while the use of iterative reconstruction (IR) can result in an underestimation due to reduced noise. The objective of this study was to determine the influence of dose reduction and hybrid IR (HIR) or model-based IR (MIR) on CT emphysema quantification. METHODS: Twenty-two patients underwent inspiratory chest CT scan at routine radiation dose and at 45%, 60% and 75% reduced radiation dose. Acquisitions were reconstructed with FBP, HIR and MIR. Emphysema was quantified using the 15th percentile of the attenuation curve and the percentage of voxels below -950 HU. To determine whether the use of a different percentile or HU threshold is more accurate at reduced dose levels and with IR, additional measurements were performed using different percentiles and HU thresholds to determine the optimal combination. RESULTS: Dose reduction resulted in a significant overestimation of emphysema, while HIR and MIR resulted in an underestimation. Lower HU thresholds with FBP at reduced dose and higher HU thresholds with HIR and MIR resulted in emphysema percentages comparable to the reference. The 15th percentile quantification method showed similar results as the HU threshold method. CONCLUSIONS: This within-patients study showed that CT emphysema quantification is significantly affected by dose reduction and IR. This can potentially be solved by adapting commonly used thresholds.

17.
PLoS One ; 12(4): e0175714, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28410386

RESUMO

BACKGROUND: To study dose reduction using iterative reconstruction (IR) for pediatric great vessel stent computed tomography (CT). METHODS: Five different great vessel stents were separately placed in a gel-containing plastic holder within an anthropomorphic chest phantom. The stent lumen was filled with diluted contrast gel. CT acquisitions were performed at routine dose, 52% and 81% reduced dose and reconstructed with filtered back projection (FBP) and IR. Objective image quality in terms of noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) as well as subjective image quality were evaluated. RESULTS: Noise, SNR and CNR were improved with IR at routine and 52% reduced dose, compared to FBP at routine dose. The lowest dose level resulted in decreased objective image quality with both FBP and IR. Subjective image quality was excellent at all dose levels. CONCLUSION: IR resulted in improved objective image quality at routine dose and 52% reduced dose, while objective image quality deteriorated at 81% reduced dose. Subjective image quality was not affected by dose reduction.


Assuntos
Stents , Tomografia Computadorizada por Raios X , Algoritmos , Criança , Humanos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Razão Sinal-Ruído
18.
IEEE Trans Med Imaging ; 25(4): 451-63, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16608060

RESUMO

Computed tomography (CT) has become the new reference standard for quantification of emphysema. The most popular measure of emphysema derived from CT is the pixel index (PI), which expresses the fraction of the lung volume with abnormally low intensity values. As PI is calculated from a single, fixed threshold on intensity, this measure is strongly influenced by noise. This effect shows up clearly when comparing the PI score of a high-dose scan to the PI score of a low-dose (i.e., noisy) scan of the same subject. In this paper, the noise variance (NOVA) filter is presented: a general framework for (iterative) nonlinear filtering, which uses an estimate of the spatially dependent noise variance in an image. The NOVA filter iteratively estimates the local image noise and filters the image. For the specific purpose of emphysema quantification of low-dose CT images, a dedicated, noniterative NOVA filter is constructed by using prior knowledge of the data to obtain a good estimate of the spatially dependent noise in an image. The performance of the NOVA filter is assessed by comparing characteristics of pairs of high-dose and low-dose scans. The compared characteristics are the PI scores for different thresholds and the size distributions of emphysema bullae. After filtering, the PI scores of high-dose and low-dose images agree to within 2%-3% points. The reproducibility of the high-dose bullae size distribution is also strongly improved. NOVA filtering of a CT image of typically 400 x 512 x 512 voxels takes only a couple of minutes which makes it suitable for routine use in clinical practice.


Assuntos
Algoritmos , Enfisema Pulmonar/classificação , Enfisema Pulmonar/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Processamento de Sinais Assistido por Computador , Tomografia Computadorizada por Raios X/métodos , Artefatos , Inteligência Artificial , Humanos , Armazenamento e Recuperação da Informação/métodos , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Processos Estocásticos
19.
Med Image Anal ; 10(2): 247-58, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16293441

RESUMO

A computer algorithm for nodule detection in chest radiographs is presented. The algorithm consists of four main steps: (i) image preprocessing; (ii) nodule candidate detection; (iii) feature extraction; (iv) candidate classification. Two optional extensions to this scheme are tested: candidate selection and candidate segmentation. The output of step (ii) is a list of circles, which can be transformed into more detailed contours by the extra candidate segmentation step. In addition, the candidate selection step (which is a classification step using a small number of features) can be used to reduce the list of nodule candidates before step (iii). The algorithm uses multi-scale techniques in several stages of the scheme: Candidates are found by looking for local intensity maxima in Gaussian scale space; nodule boundaries are detected by tracing edge points found at large scales down to pixel scale; some of the features used for classification are taken from a multi-scale Gaussian filterbank. Experiments with this scheme (with and without the segmentation and selection steps) are carried out on a previously characterized, publicly available database, that contains a large number of very subtle nodules. For this database, counting as detections only those nodules that were indicated with a confidence level of 50% or more, radiologists previously detected 70% of the nodules. For our algorithm, it turns out that the selection step does have an added value for the system, while segmentation does not lead to a clear improvement. With the scheme with the best performance, accepting on average two false positives per image results in the identification of 51% of all nodules. For four false positives, this increases to 67%. This is close to the previously reported 70% detection rate of the radiologists.


Assuntos
Inteligência Artificial , Bases de Dados Factuais , Reconhecimento Automatizado de Padrão/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Algoritmos , Análise por Conglomerados , Humanos , Imageamento Tridimensional/métodos , Neoplasias Pulmonares/classificação , Neoplasias Pulmonares/diagnóstico por imagem , Sistemas Computadorizados de Registros Médicos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Nódulo Pulmonar Solitário/classificação
20.
J Cardiovasc Comput Tomogr ; 10(1): 69-75, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26342405

RESUMO

OBJECTIVE: To assess the maximally achievable computed tomography (CT) dose reduction for coronary artery calcium (CAC) scoring with iterative reconstruction (IR) by using phantom-experiments and a systematical within-patient study. METHODS: Our local institutional review-board approved this study and informed consent was obtained from all participants. A phantom and patient study were conducted with 30 patients (23 men, median age 55.0 (52.0-56.0) years) who underwent 256-slice electrocardiogram-triggered CAC-scoring at four dose levels (routine, 60%, 40%, and 20%-dose) in a single session. Tube-voltage was 120 kVp, tube-current was lowered to achieve stated dose levels. Data were reconstructed with filtered back-projection (FBP) and three IR levels. Agatston, volume and mass scores were determined with validated software and compared using Wilcoxon signed ranks-tests. Subsequently, patient reclassification was analyzed. RESULTS: The phantom study showed that Agatston scores remained nearly stable with FBP between routine-dose and 40%-dose and increased substantially at lower dose. Twenty-three patients (77%) had coronary calcifications. For Agatston scoring, one 40%-dose and six 20%-dose FBP reconstructions were not interpretable due to noise. In contrast, with IR all reconstructions were interpretable. Median Agatston scores increased with FBP from 26.1 (5.2-192.2) at routine-dose to 60.5 (11.6-251.7) at 20% dose. However, IR lowered Agatston scores to 22.9 (5.9-195.5) at 20%-dose and strong IR (level 7) with Agatston reclassifications in 15%. CONCLUSION: IR allows for CAC-scoring radiation dose reductions of up to 80% resulting in effective doses between 0.15 and 0.18 mSv. At these dose-levels, reclassification-rates remain within 15% if the highest IR-level is applied.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Exposição à Radiação/prevenção & controle , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Calcificação Vascular/diagnóstico por imagem , Algoritmos , Relação Dose-Resposta à Radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Exposição à Radiação/análise , Proteção Radiológica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa