Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Nat Methods ; 21(5): 809-813, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38605111

RESUMO

Neuroscience is advancing standardization and tool development to support rigor and transparency. Consequently, data pipeline complexity has increased, hindering FAIR (findable, accessible, interoperable and reusable) access. brainlife.io was developed to democratize neuroimaging research. The platform provides data standardization, management, visualization and processing and automatically tracks the provenance history of thousands of data objects. Here, brainlife.io is described and evaluated for validity, reliability, reproducibility, replicability and scientific utility using four data modalities and 3,200 participants.


Assuntos
Computação em Nuvem , Neurociências , Neurociências/métodos , Humanos , Neuroimagem/métodos , Reprodutibilidade dos Testes , Software , Encéfalo/fisiologia , Encéfalo/diagnóstico por imagem
2.
Mol Psychiatry ; 28(10): 4342-4352, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37495890

RESUMO

22q11.2 deletion syndrome, or 22q11.2DS, is a genetic syndrome associated with high rates of schizophrenia and autism spectrum disorders, in addition to widespread structural and functional abnormalities throughout the brain. Experimental animal models have identified neuronal connectivity deficits, e.g., decreased axonal length and complexity of axonal branching, as a primary mechanism underlying atypical brain development in 22q11.2DS. However, it is still unclear whether deficits in axonal morphology can also be observed in people with 22q11.2DS. Here, we provide an unparalleled in vivo characterization of white matter microstructure in participants with 22q11.2DS (12-15 years) and those undergoing typical development (8-18 years) using a customized magnetic resonance imaging scanner which is sensitive to axonal morphology. A rich array of diffusion MRI metrics are extracted to present microstructural profiles of typical and atypical white matter development, and provide new evidence of connectivity differences in individuals with 22q11.2DS. A recent, large-scale consortium study of 22q11.2DS identified higher diffusion anisotropy and reduced overall diffusion mobility of water as hallmark microstructural alterations of white matter in individuals across a wide age range (6-52 years). We observed similar findings across the white matter tracts included in this study, in addition to identifying deficits in axonal morphology. This, in combination with reduced tract volume measurements, supports the hypothesis that abnormal microstructural connectivity in 22q11.2DS may be mediated by densely packed axons with disproportionately small diameters. Our findings provide insight into the in vivo white matter phenotype of 22q11.2DS, and promote the continued investigation of shared features in neurodevelopmental and psychiatric disorders.


Assuntos
Síndrome de DiGeorge , Esquizofrenia , Substância Branca , Humanos , Criança , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Síndrome de DiGeorge/genética , Imagem de Tensor de Difusão/métodos , Encéfalo
3.
Radiology ; 307(3): e221473, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36916889

RESUMO

Background Exhaustion of cerebrovascular reactivity (CVR) portends increased stroke risk. Acetazolamide-augmented blood oxygenation level-dependent (BOLD) MRI has been used to estimate CVR, but low signal-to-noise conditions relegate its use to terminal CVR (CVRend) measurements that neglect dynamic features of CVR. Purpose To demonstrate comprehensive characterization of acetazolamide-augmented BOLD MRI response in chronic steno-occlusive disease using a computational framework to precondition signal time courses for dynamic whole-brain CVR analysis. Materials and Methods This study focused on retrospective analysis of consecutive patients with unilateral chronic steno-occlusive disease who underwent acetazolamide-augmented BOLD imaging for recurrent minor stroke or transient ischemic attack at an academic medical center between May 2017 and October 2020. A custom principal component analysis-based denoising pipeline was used to correct spatially varying non-signal-bearing contributions obtained by a local principal component analysis of the MRI time series. Standard voxelwise CVRend maps representing terminal responses were produced and compared with maximal CVR (CVRmax) as isolated from binned (per-repetition time) denoised BOLD time course. A linear mixed-effects model was used to compare CVRmax and CVRend in healthy and diseased hemispheres. Results A total of 23 patients (median age, 51 years; IQR, 42-61, 13 men) who underwent 32 BOLD examinations were included. Processed MRI data showed twofold improvement in signal-to-noise ratio, allowing improved isolation of dynamic characteristics in signal time course for sliding window CVRmax analysis to the level of each BOLD repetition time (approximately 2 seconds). Mean CVRmax was significantly higher than mean CVRend in diseased (5.2% vs 3.8%, P < .01) and healthy (5.5% vs 4.0%, P < .01) hemispheres. Several distinct time-signal signatures were observed, including nonresponsive; delayed/blunted; brisk; and occasionally nonmonotonic time courses with paradoxical features in normal and abnormal tissues (ie, steal and reverse-steal patterns). Conclusion A principal component analysis-based computational framework for analysis of acetazolamide-augmented BOLD imaging can be used to measure unsustained CVRmax through twofold improvements in signal-to-noise ratio. © RSNA, 2023 Supplemental material is available for this article.


Assuntos
Acetazolamida , Transtornos Cerebrovasculares , Masculino , Humanos , Pessoa de Meia-Idade , Análise de Componente Principal , Estudos Retrospectivos , Circulação Cerebrovascular/fisiologia , Encéfalo , Imageamento por Ressonância Magnética/métodos
4.
J Magn Reson Imaging ; 58(5): 1462-1469, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-36995159

RESUMO

BACKGROUND: Crossed cerebellar diaschisis (CCD) refers to depressions in perfusion and metabolism within the cerebellar hemisphere contralateral to supratentorial disease. Prior investigation into CCD in cerebrovascular reactivity (CVR) has been limited to terminal CVR estimations (CVRend ). We recently have demonstrated the presence of unsustained CVR maxima (CVRmax ) using dynamic CVR analysis, offering a fully dynamic characterization of CVR to hemodynamic stimuli. PURPOSE: To investigate CCD in CVRmax from dynamic blood oxygen level-dependent (BOLD) MRI, by comparison with conventional CVRend estimation. STUDY TYPE: Retrospective. POPULATION: A total of 23 patients (median age: 51 years, 10 females) with unilateral chronic steno-occlusive cerebrovascular disease, without prior knowledge of CCD status. FIELD STRENGTH/SEQUENCE: A 3-T, T1-weighted magnetization-prepared rapid gradient-echo (MPRAGE) and acetazolamide-augmented BOLD imaging performed with a gradient-echo echo-planar imaging (EPI) sequence. ASSESSMENT: A custom denoising pipeline was used to generate BOLD-CVR time signals. CVRend was established using the last minute of the BOLD response relative to the first-minute baseline. Following classification of healthy versus diseased cerebral hemispheres, CVRmax and CVRend were calculated for bilateral cerebral and cerebellar hemispheres. Three independent observers evaluated all data for the presence of CCD. STATISTICAL TESTS: Pearson correlations for comparing CVR across hemispheres, two-proportion Z-tests for comparing CCD prevalence, and Wilcoxon signed-rank tests for comparing median CVR. The level of statistical significance was set at P ≤ 0.05. RESULTS: CCD-related changes were observed on both CVRend and CVRmax maps, with all CCD+ cases identifiable by inspection of either map. Diseased cerebral and contralateral cerebellar hemispheric CVR correlations in CCD+ patients were stronger when using CVRend (r = 0.728) as compared to CVRmax (r = 0.676). CVR correlations between healthy cerebral hemispheres and contralateral cerebellar hemispheres were stronger for CVRmax (r = 0.739) than for CVRend (r = 0.705). DATA CONCLUSION: CCD-related alterations could be observed in CVR examinations. Conventional CVRend may underestimate CVR and could exaggerate CCD. EVIDENCE LEVEL: 4. TECHNICAL EFFICACY: Stage 3.


Assuntos
Transtornos Cerebrovasculares , Diásquise , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Circulação Cerebrovascular , Hemodinâmica , Imageamento por Ressonância Magnética/métodos
5.
J Magn Reson Imaging ; 58(1): 210-220, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36399101

RESUMO

BACKGROUND: Renal diffusion-weighted imaging (DWI) involves microstructure and microcirculation, quantified with diffusion tensor imaging (DTI), intravoxel incoherent motion (IVIM), and hybrid models. A better understanding of their contrast may increase specificity. PURPOSE: To measure modulation of DWI with cardiac phase and flow-compensated (FC) diffusion gradient waveforms. STUDY TYPE: Prospective. POPULATION: Six healthy volunteers (ages: 22-48 years, five females), water phantom. FIELD STRENGTH/SEQUENCE: 3-T, prototype DWI sequence with 2D echo-planar imaging, and bipolar (BP) or FC gradients. 2D Half-Fourier Single-shot Turbo-spin-Echo (HASTE). Multiple-phase 2D spoiled gradient-echo phase contrast (PC) MRI. ASSESSMENT: BP and FC water signal decays were qualitatively compared. Renal arteries and velocities were visualized on PC-MRI. Systolic (peak velocity), diastolic (end stable velocity), and pre-systolic (before peak velocity) phases were identified. Following mutual information-based retrospective self-registration of DWI within each kidney, and Marchenko-Pastur Principal Component Analysis (MPPCA) denoising, combined IVIM-DTI analysis estimated mean diffusivity (MD), fractional anisotropy (FA), and eigenvalues (λi) from tissue diffusivity (Dt ), perfusion fraction (fp ), and pseudodiffusivity (Dp , Dp,axial , Dp,radial ), for each tissue (cortex/medulla, segmented on b0/FA respectively), phase, and waveform (BP, FC). Monte Carlo water diffusion simulations aided data interpretation. STATISTICAL TESTS: Mixed model regression probed differences between tissue types and pulse sequences. Univariate general linear model analysis probed variations among cardiac phases. Spearman correlations were measured between diffusion metrics and renal artery velocities. Statistical significance level was set at P < 0.05. RESULTS: Water BP and FC signal decays showed no differences. Significant pulse sequence dependence occurred for λ1 , λ3 , FA, Dp , fp , Dp,axial , Dp,radial in cortex and medulla, and medullary λ2 . Significant cortex/medulla differences occurred with BP for all metrics except MD (systole [P = 0.224]; diastole [P = 0.556]). Significant phase dependence occurred for Dp , Dp,axial , Dp,radial for BP and medullary λ1 , λ2 , λ3 , MD for FC. FA correlated significantly with velocity. Monte Carlo simulations indicated medullary measurements were consistent with a 34 µm tubule diameter. DATA CONCLUSION: Cardiac gating and flow compensation modulate of measurements of renal diffusion. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Imagem de Tensor de Difusão , Rim , Feminino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Imagem de Tensor de Difusão/métodos , Anisotropia , Estudos Prospectivos , Estudos Retrospectivos , Rim/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Movimento (Física) , Água
6.
Neuroimage ; 249: 118830, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-34965454

RESUMO

Diffusion MRI (dMRI) provides invaluable information for the study of tissue microstructure and brain connectivity, but suffers from a range of imaging artifacts that greatly challenge the analysis of results and their interpretability if not appropriately accounted for. This review will cover dMRI artifacts and preprocessing steps, some of which have not typically been considered in existing pipelines or reviews, or have only gained attention in recent years: brain/skull extraction, B-matrix incompatibilities w.r.t the imaging data, signal drift, Gibbs ringing, noise distribution bias, denoising, between- and within-volumes motion, eddy currents, outliers, susceptibility distortions, EPI Nyquist ghosts, gradient deviations, B1 bias fields, and spatial normalization. The focus will be on "what's new" since the notable advances prior to and brought by the Human Connectome Project (HCP), as presented in the predecessing issue on "Mapping the Connectome" in 2013. In addition to the development of novel strategies for dMRI preprocessing, exciting progress has been made in the availability of open source tools and reproducible pipelines, databases and simulation tools for the evaluation of preprocessing steps, and automated quality control frameworks, amongst others. Finally, this review will consider practical considerations and our view on "what's next" in dMRI preprocessing.


Assuntos
Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Processamento de Imagem Assistida por Computador , Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/normas , Imagem de Difusão por Ressonância Magnética/tendências , Humanos , Processamento de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/normas , Processamento de Imagem Assistida por Computador/tendências
7.
Neuroimage ; 256: 119219, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35447354

RESUMO

The free water elimination (FWE) model and its kurtosis variant (DKI-FWE) can separate tissue and free water signal contributions, thus providing tissue-specific diffusional information. However, a downside of these models is that the associated parameter estimation problem is ill-conditioned, necessitating the use of advanced estimation techniques that can potentially bias the parameter estimates. In this work, we propose the T2-DKI-FWE model that exploits the T2 relaxation properties of both compartments, thereby better conditioning the parameter estimation problem and providing, at the same time, an additional potential biomarker (the T2 of tissue). In our approach, the T2 of tissue is estimated as an unknown parameter, whereas the T2 of free water is assumed known a priori and fixed to a literature value (1573 ms). First, the error propagation of an erroneous assumption on the T2 of free water is studied. Next, the improved conditioning of T2-DKI-FWE compared to DKI-FWE is illustrated using the Cramér-Rao lower bound matrix. Finally, the performance of the T2-DKI-FWE model is compared to that of the DKI-FWE and T2-DKI models on both simulated and real datasets. The error due to a biased approximation of the T2 of free water was found to be relatively small in various diffusion metrics and for a broad range of erroneous assumptions on its underlying ground truth value. Compared to DKI-FWE, using the T2-DKI-FWE model is beneficial for the identifiability of the model parameters. Our results suggest that the T2-DKI-FWE model can achieve precise and accurate diffusion parameter estimates, through effective reduction of free water partial volume effects and by using a standard nonlinear least squares approach. In conclusion, incorporating T2 relaxation properties into the DKI-FWE model improves the conditioning of the model fitting, while only requiring an acquisition scheme with at least two different echo times.


Assuntos
Imagem de Tensor de Difusão , Água , Benchmarking , Encéfalo/metabolismo , Difusão , Imagem de Difusão por Ressonância Magnética , Imagem de Tensor de Difusão/métodos , Humanos , Água/metabolismo
8.
Neuroimage ; 257: 119290, 2022 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-35545197

RESUMO

Estimating intra- and extra-axonal microstructure parameters, such as volume fractions and diffusivities, has been one of the major efforts in brain microstructure imaging with MRI. The Standard Model (SM) of diffusion in white matter has unified various modeling approaches based on impermeable narrow cylinders embedded in locally anisotropic extra-axonal space. However, estimating the SM parameters from a set of conventional diffusion MRI (dMRI) measurements is ill-conditioned. Multidimensional dMRI helps resolve the estimation degeneracies, but there remains a need for clinically feasible acquisitions that yield robust parameter maps. Here we find optimal multidimensional protocols by minimizing the mean-squared error of machine learning-based SM parameter estimates for two 3T scanners with corresponding gradient strengths of 40and80mT/m. We assess intra-scanner and inter-scanner repeatability for 15-minute optimal protocols by scanning 20 healthy volunteers twice on both scanners. The coefficients of variation all SM parameters except free water fraction are ≲10% voxelwise and 1-4% for their region-averaged values. As the achieved SM reproducibility outcomes are similar to those of conventional diffusion tensor imaging, our results enable robust in vivo mapping of white matter microstructure in neuroscience research and in the clinic.


Assuntos
Substância Branca , Encéfalo/diagnóstico por imagem , Difusão , Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Tensor de Difusão/métodos , Humanos , Reprodutibilidade dos Testes , Substância Branca/diagnóstico por imagem
10.
Hum Brain Mapp ; 42(7): 2201-2213, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33576105

RESUMO

The noninvasive quantification of axonal morphology is an exciting avenue for gaining understanding of the function and structure of the central nervous system. Accurate non-invasive mapping of micron-sized axon radii using commonly applied neuroimaging techniques, that is, diffusion-weighted MRI, has been bolstered by recent hardware developments, specifically MR gradient design. Here the whole brain characterization of the effective MR axon radius is presented and the inter- and intra-scanner test-retest repeatability and reproducibility are evaluated to promote the further development of the effective MR axon radius as a neuroimaging biomarker. A coefficient-of-variability of approximately 10% in the voxelwise estimation of the effective MR radius is observed in the test-retest analysis, but it is shown that the performance can be improved fourfold using a customized along-tract analysis.


Assuntos
Axônios , Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/normas , Neuroimagem/normas , Substância Branca/diagnóstico por imagem , Adulto , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Neuroimagem/métodos , Reprodutibilidade dos Testes
11.
Radiology ; 298(2): 365-373, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33289611

RESUMO

Background Functional MRI improves preoperative planning in patients with brain tumors, but task-correlated signal intensity changes are only 2%-3% above baseline. This makes accurate functional mapping challenging. Marchenko-Pastur principal component analysis (MP-PCA) provides a novel strategy to separate functional MRI signal from noise without requiring user input or prior data representation. Purpose To determine whether MP-PCA denoising improves activation magnitude for task-based functional MRI language mapping in patients with brain tumors. Materials and Methods In this Health Insurance Portability and Accountability Act-compliant study, MP-PCA performance was first evaluated by using simulated functional MRI data with a known ground truth. Right-handed, left-language-dominant patients with brain tumors who successfully performed verb generation, sentence completion, and finger tapping functional MRI tasks were retrospectively identified between January 2017 and August 2018. On the group level, for each task, histograms of z scores for original and MP-PCA denoised data were extracted from relevant regions and contralateral homologs were seeded by a neuroradiologist blinded to functional MRI findings. Z scores were compared with paired two-sided t tests, and distributions were compared with effect size measurements and the Kolmogorov-Smirnov test. The number of voxels with a z score greater than 3 was used to measure task sensitivity relative to task duration. Results Twenty-three patients (mean age ± standard deviation, 43 years ± 18; 13 women) were evaluated. MP-PCA denoising led to a higher median z score of task-based functional MRI voxel activation in left hemisphere cortical regions for verb generation (from 3.8 ± 1.0 to 4.5 ± 1.4; P < .001), sentence completion (from 3.7 ± 1.0 to 4.3 ± 1.4; P < .001), and finger tapping (from 6.9 ± 2.4 to 7.9 ± 2.9; P < .001). Median z scores did not improve in contralateral homolog regions for verb generation (from -2.7 ± 0.54 to -2.5 ± 0.40; P = .90), sentence completion (from -2.3 ± 0.21 to -2.4 ± 0.37; P = .39), or finger tapping (from -2.3 ± 1.20 to -2.7 ± 1.40; P = .07). Individual functional MRI task durations could be truncated by at least 40% after MP-PCA without degradation of clinically relevant correlations between functional cortex and functional MRI tasks. Conclusion Denoising with Marchenko-Pastur principal component analysis led to higher task correlations in relevant cortical regions during functional MRI language mapping in patients with brain tumors. © RSNA, 2020 Online supplemental material is available for this article.


Assuntos
Mapeamento Encefálico/métodos , Neoplasias Encefálicas/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Encéfalo/diagnóstico por imagem , Criança , Feminino , Humanos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Análise de Componente Principal , Estudos Retrospectivos , Adulto Jovem
12.
Magn Reson Med ; 86(3): 1600-1613, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33829542

RESUMO

PURPOSE: The general utility of diffusion kurtosis imaging (DKI) is challenged by its poor robustness to imaging artifacts and thermal noise that often lead to implausible kurtosis values. THEORY AND METHODS: A robust scalar kurtosis index can be estimated from powder-averaged diffusion-weighted data. We introduce a novel DKI estimator that uses this scalar kurtosis index as a proxy for the mean kurtosis to regularize the fit. RESULTS: The regularized DKI estimator improves the robustness and reproducibility of the kurtosis metrics and results in parameter maps with enhanced quality and contrast. CONCLUSION: Our novel DKI estimator promotes the wider use of DKI in clinical research and potentially diagnostics by improving the reproducibility and precision of DKI fitting and, as such, enabling enhanced visual, quantitative, and statistical analyses of DKI parameters.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem de Tensor de Difusão , Benchmarking , Difusão , Reprodutibilidade dos Testes
13.
Neuroimage ; 208: 116460, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31843710

RESUMO

Probing microstructure with diffusion magnetic resonance imaging (dMRI) on a scale orders of magnitude below the imaging resolution relies on biophysical modelling of the signal response in the tissue. The vast majority of these biophysical models of diffusion in white matter assume that the measured dMRI signal is the sum of the signals emanating from each of the constituent compartments, each of which exhibits a distinct behaviour in the b-value and/or orientation domain. Many of these models further assume that the dMRI behaviour of the oriented compartments (e.g. the intra-axonal space) is identical between distinct fibre populations, at least at the level of a single voxel. This implicitly assumes that any potential biological differences between fibre populations are negligible, at least as far as is measurable using dMRI. Here, we validate this assumption by means of a voxel-wise, model-free signal decomposition that, under the assumption above and in the absence of noise, is shown to be rank-1. We evaluate the effect size of signal components beyond this rank-1 representation and use permutation testing to assess their significance. We conclude that in the healthy adult brain, the dMRI signal is adequately represented by a rank-1 model, implying that biologically more realistic, but mathematically more complex fascicle-specific microstructure models do not capture statistically significant or anatomically meaningful structure, even in extended high-b diffusion MRI scans.


Assuntos
Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Modelos Teóricos , Neuroimagem/métodos , Adulto , Humanos
14.
Neuroimage ; 217: 116884, 2020 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-32360689

RESUMO

Multi-parametric quantitative MRI (qMRI) of the spinal cord is a promising non-invasive tool to probe early microstructural damage in neurological disorders. It is usually performed in vivo by combining acquisitions with multiple signal readouts, which exhibit different thermal noise levels, geometrical distortions and susceptibility to physiological noise. This ultimately hinders joint multi-contrast modelling and makes the geometric correspondence of parametric maps challenging. We propose an approach to overcome these limitations, by implementing state-of-the-art microstructural MRI of the spinal cord with a unified signal readout in vivo (i.e. with matched spatial encoding parameters across a range of imaging contrasts). We base our acquisition on single-shot echo planar imaging with reduced field-of-view, and obtain data from two different vendors (vendor 1: Philips Achieva; vendor 2: Siemens Prisma). Importantly, the unified acquisition allows us to compare signal and noise across contrasts, thus enabling overall quality enhancement via multi-contrast image denoising methods. As a proof-of-concept, here we provide a demonstration with one such method, known as Marchenko-Pastur (MP) Principal Component Analysis (PCA) denoising. MP-PCA is a singular value (SV) decomposition truncation approach that relies on redundant acquisitions, i.e. such that the number of measurements is large compared to the number of components that are maintained in the truncated SV decomposition. Here we used in vivo and synthetic data to test whether a unified readout enables more efficient MP-PCA denoising of less redundant acquisitions, since these can be denoised jointly with more redundant ones. We demonstrate that a unified readout provides robust multi-parametric maps, including diffusion and kurtosis tensors from diffusion MRI, myelin metrics from two-pool magnetisation transfer, and T1 and T2 from relaxometry. Moreover, we show that MP-PCA improves the quality of our multi-contrast acquisitions, since it reduces the coefficient of variation (i.e. variability) by up to 17% for mean kurtosis, 8% for bound pool fraction (myelin-sensitive), and 13% for T1, while enabling more efficient denoising of modalities limited in redundancy (e.g. relaxometry). In conclusion, multi-parametric spinal cord qMRI with unified readout is feasible and provides robust microstructural metrics with matched resolution and distortions, whose quality benefits from multi-contrast denoising methods such as MP-PCA.


Assuntos
Imagem Ecoplanar/métodos , Medula Espinal/diagnóstico por imagem , Algoritmos , Simulação por Computador , Imagem de Tensor de Difusão , Imagem Ecoplanar/instrumentação , Humanos , Aumento da Imagem , Interpretação de Imagem Assistida por Computador , Bainha de Mielina/patologia , Análise de Componente Principal , Razão Sinal-Ruído
15.
Neuroimage ; 221: 117128, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32673745

RESUMO

Cross-scanner and cross-protocol variability of diffusion magnetic resonance imaging (dMRI) data are known to be major obstacles in multi-site clinical studies since they limit the ability to aggregate dMRI data and derived measures. Computational algorithms that harmonize the data and minimize such variability are critical to reliably combine datasets acquired from different scanners and/or protocols, thus improving the statistical power and sensitivity of multi-site studies. Different computational approaches have been proposed to harmonize diffusion MRI data or remove scanner-specific differences. To date, these methods have mostly been developed for or evaluated on single b-value diffusion MRI data. In this work, we present the evaluation results of 19 algorithms that are developed to harmonize the cross-scanner and cross-protocol variability of multi-shell diffusion MRI using a benchmark database. The proposed algorithms rely on various signal representation approaches and computational tools, such as rotational invariant spherical harmonics, deep neural networks and hybrid biophysical and statistical approaches. The benchmark database consists of data acquired from the same subjects on two scanners with different maximum gradient strength (80 and 300 â€‹mT/m) and with two protocols. We evaluated the performance of these algorithms for mapping multi-shell diffusion MRI data across scanners and across protocols using several state-of-the-art imaging measures. The results show that data harmonization algorithms can reduce the cross-scanner and cross-protocol variabilities to a similar level as scan-rescan variability using the same scanner and protocol. In particular, the LinearRISH algorithm based on adaptive linear mapping of rotational invariant spherical harmonics features yields the lowest variability for our data in predicting the fractional anisotropy (FA), mean diffusivity (MD), mean kurtosis (MK) and the rotationally invariant spherical harmonic (RISH) features. But other algorithms, such as DIAMOND, SHResNet, DIQT, CMResNet show further improvement in harmonizing the return-to-origin probability (RTOP). The performance of different approaches provides useful guidelines on data harmonization in future multi-site studies.


Assuntos
Algoritmos , Encéfalo/diagnóstico por imagem , Aprendizado Profundo , Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Neuroimagem/métodos , Adulto , Imagem de Difusão por Ressonância Magnética/instrumentação , Imagem de Difusão por Ressonância Magnética/normas , Humanos , Processamento de Imagem Assistida por Computador/normas , Neuroimagem/instrumentação , Neuroimagem/normas , Análise de Regressão
16.
Neuroradiology ; 62(7): 791-802, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32367349

RESUMO

PURPOSE: We aim to illustrate the diagnostic performance of diffusional kurtosis imaging (DKI) in the diagnosis of gliomas. METHODS: A review protocol was developed according to the (PRISMA-P) checklist, registered in the international prospective register of systematic reviews (PROSPERO) and published. A literature search in 4 databases was performed using the keywords 'glioma' and 'diffusional kurtosis'. After applying a robust inclusion/exclusion criteria, included articles were independently evaluated according to the QUADAS-2 tool and data extraction was done. Reported sensitivities and specificities were used to construct 2 × 2 tables and paired forest plots using the Review Manager (RevMan®) software. A random-effect model was pursued using the hierarchical summary receiver operator characteristics. RESULTS: A total of 216 hits were retrieved. Considering duplicates and inclusion criteria, 23 articles were eligible for full-text reading. Ultimately, 19 studies were eligible for final inclusion. The quality assessment revealed 9 studies with low risk of bias in the 4 domains. Using a bivariate random-effect model for data synthesis, summary ROC curve showed a pooled area under the curve (AUC) of 0.92 and estimated sensitivity of 0.87 (95% CI 0.78-0.92) in high-/low-grade gliomas' differentiation. A mean difference in mean kurtosis (MK) value between HGG and LGG of 0.22 (95% CI 0.25-0.19) was illustrated (p value = 0.0014) with moderate heterogeneity (I2 = 73.8%). CONCLUSION: DKI shows good diagnostic accuracy in the differentiation of high- and low-grade gliomas further supporting its potential role in clinical practice. Further exploration of DKI in differentiating IDH status and in characterising non-glioma CNS tumours is however needed.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Imagem de Tensor de Difusão/métodos , Glioma/diagnóstico por imagem , Glioma/patologia , Diagnóstico Diferencial , Humanos , Interpretação de Imagem Assistida por Computador , Gradação de Tumores
17.
Neuroimage ; 185: 379-387, 2019 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-30292815

RESUMO

Development of therapies for neurological disorders depends on our ability to non-invasively diagnose and monitor the progression of underlying pathologies at the cellular level. Physics and physiology limit the resolution of human MRI to be orders of magnitude coarser than cell dimensions. Here we identify and quantify the MRI signal coming from within micrometer-thin axons in human white matter tracts in vivo, by utilizing the sensitivity of diffusion MRI to Brownian motion of water molecules restricted by cell walls. We study a specific power-law scaling of the diffusion MRI signal with the diffusion weighting, predicted for water confined to narrow axons, and quantify axonal water fraction and orientation dispersion.


Assuntos
Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Neuroimagem/métodos , Substância Branca/diagnóstico por imagem , Difusão , Humanos , Água
18.
Neuroimage ; 195: 285-299, 2019 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-30716459

RESUMO

Diffusion MRI is being used increasingly in studies of the brain and other parts of the body for its ability to provide quantitative measures that are sensitive to changes in tissue microstructure. However, inter-scanner and inter-protocol differences are known to induce significant measurement variability, which in turn jeopardises the ability to obtain 'truly quantitative measures' and challenges the reliable combination of different datasets. Combining datasets from different scanners and/or acquired at different time points could dramatically increase the statistical power of clinical studies, and facilitate multi-centre research. Even though careful harmonisation of acquisition parameters can reduce variability, inter-protocol differences become almost inevitable with improvements in hardware and sequence design over time, even within a site. In this work, we present a benchmark diffusion MRI database of the same subjects acquired on three distinct scanners with different maximum gradient strength (40, 80, and 300 mT/m), and with 'standard' and 'state-of-the-art' protocols, where the latter have higher spatial and angular resolution. The dataset serves as a useful testbed for method development in cross-scanner/cross-protocol diffusion MRI harmonisation and quality enhancement. Using the database, we compare the performance of five different methods for estimating mappings between the scanners and protocols. The results show that cross-scanner harmonisation of single-shell diffusion data sets can reduce the variability between scanners, and highlight the promises and shortcomings of today's data harmonisation techniques.


Assuntos
Algoritmos , Benchmarking/métodos , Mapeamento Encefálico/métodos , Imagem de Difusão por Ressonância Magnética/normas , Processamento de Imagem Assistida por Computador/métodos , Adulto , Benchmarking/normas , Mapeamento Encefálico/normas , Bases de Dados como Assunto , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Processamento de Imagem Assistida por Computador/normas , Masculino , Adulto Jovem
19.
Proc Natl Acad Sci U S A ; 113(47): 13504-13509, 2016 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-27834215

RESUMO

Schizophrenia, a devastating psychiatric illness with onset in the late teens to early 20s, is thought to involve disrupted brain connectivity. Functional and structural disconnections of cortical networks may underlie various cognitive deficits, including a substantial reduction in the speed of information processing in schizophrenia patients compared with controls. Myelinated white matter supports the speed of electrical signal transmission in the brain. To examine possible neuroanatomical sources of cognitive deficits, we used a comprehensive diffusion-weighted imaging (DWI) protocol and characterized the white matter diffusion signals using diffusion kurtosis imaging (DKI) and permeability-diffusivity imaging (PDI) in patients (n = 74), their nonill siblings (n = 41), and healthy controls (n = 113). Diffusion parameters that showed significant patient-control differences also explained the patient-control differences in processing speed. This association was also found for the nonill siblings of the patients. The association was specific to processing-speed abnormality but not specific to working memory abnormality or psychiatric symptoms. Our findings show that advanced diffusion MRI in white matter may capture microstructural connectivity patterns and mechanisms that govern the association between a core neurocognitive measure-processing speed-and neurobiological deficits in schizophrenia that are detectable with in vivo brain scans. These non-Gaussian diffusion white matter metrics are promising surrogate imaging markers for modeling cognitive deficits and perhaps, guiding treatment development in schizophrenia.


Assuntos
Imagem de Tensor de Difusão , Processos Mentais/fisiologia , Esquizofrenia/fisiopatologia , Adolescente , Adulto , Anisotropia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Substância Branca/fisiopatologia , Adulto Jovem
20.
Neuroimage ; 182: 360-369, 2018 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-28935239

RESUMO

Biophysical modeling of macroscopic diffusion-weighted MRI signal in terms of microscopic cellular parameters holds the promise of quantifying the integrity of white matter. Unfortunately, even fairly simple multi-compartment models of proton diffusion in the white matter do not provide a unique, biophysically plausible solution. Here we report a nontrivial diffusion MRI signal dependence on echo time (TE) in human white matter in vivo. We demonstrate that such TE dependence originates from compartment-specific T2 values and that it is a promising "orthogonal measure" able to break the degeneracy in parameter estimation, and to yield important relaxation metrics robustly. We thereby enable the precise estimation of the intra- and extra-axonal water T2 relaxation times, which is precluded by a limited signal-to-noise ratio when using multi-echo relaxometry alone.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Modelos Teóricos , Neuroimagem/métodos , Substância Branca/anatomia & histologia , Substância Branca/diagnóstico por imagem , Adulto , Simulação por Computador , Humanos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa