Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
BMC Ophthalmol ; 23(1): 446, 2023 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-37932670

RESUMO

INTRODUCTION: Blepharophimosis, ptosis, and epicanthus inversus syndrome (BPES) is a rare genetic disease with diverse ocular malformations. This study aimed to investigate the disease-causing gene in members of a BPES pedigree presenting with the rare features of anisometropia, unilateral pathologic myopia (PM), and congenital cataracts. METHODS: The related BPES patients underwent a comprehensive ocular examination. Next, whole-exome sequencing (WES) was performed to screen for the disease-causing genetic variants. A step-wise variant filtering was performed to select candidate variants combined with the annotation of the variant's pathogenicity, which was assessed using several bioinformatic approaches. Co-segregation analysis and Sanger sequencing were then conducted to validate the candidate variant. RESULTS: The variant c.672_701dup in FOXL2 was identified to be the disease-causing variant in this rare BPES family. Combined with clinical manifestations, the two affected individuals were diagnosed with type II BPES. CONCLUSION: This study uncovered the variant c.672_701dup in FOXL2 as a disease causal variant in a rare-presenting BPES family with anisometropia, unilateral pathogenic myopia, and/or congenital cataracts, thus expanding the phenotypic spectrum of FOXL2.


Assuntos
Anisometropia , Blefarofimose , Catarata , Miopia , Humanos , Mutação , Sequenciamento do Exoma , Linhagem , Síndrome , Proteína Forkhead Box L2/genética
2.
Ophthalmology ; 129(9): 1014-1021, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35537532

RESUMO

PURPOSE: To explore whether there is a causal relationship between coffee consumption and primary open-angle glaucoma (POAG). DESIGN: Two-sample Mendelian randomization (MR). PARTICIPANTS: The single-nucleotide polymorphisms (SNPs) associated with coffee consumption (including phenotypes 1 and 2) were selected from a genome-wide association study (GWAS) involving 121 824 individuals of European descent. Coffee intake from the MRC-IEU UK Biobank was also used to identify instruments for coffee intake. Summary-level data for POAG were obtained from the largest publicly available meta-analyses involving 16 677 POAG cases and 199 580 controls of European descent. METHODS: The inverse variance-weighted (IVW) method was the main MR analysis, whereas weighted-median, weighted mode-based estimate (MBE), MR Pleiotropy RESidual Sum and Outlier (PRESSO) test, and MR-Egger regression were used for sensitivity analysis. MAIN OUTCOME MEASURES: Diagnosis of POAG. RESULTS: Three sets of instrumental variables were used to evaluate the causal association between coffee consumption and POAG risk. Results showed that genetically predicted higher coffee consumption phenotype 1 (cups/day) was significantly associated with higher risk of POAG (odds ratio [OR], 1.241; 95% confidence interval [CI], 1.041-1.480; P = 0.016). Genetically predicted higher coffee consumption phenotype 2 (high vs. no/low) was also significantly associated with higher risk of POAG (OR, 1.155; 95% CI, 1.038-1.284; P = 0.008, using the IVW method). Moreover, genetically predicted higher coffee intake from the MRC-IEU UK Biobank OpenGWAS was significantly associated with a higher risk of POAG (OR, 1.727; 95% CI, 1.230-2.425; P = 0.002, using the IVW method). Sensitivity analyses confirmed that the findings were robust to possible pleiotropy. CONCLUSIONS: These findings provide the genetic evidence that higher coffee consumption is associated with a higher risk of POAG. Given that coffee is widely consumed, our findings provide new insights into potential strategies to prevent and manage POAG.


Assuntos
Glaucoma de Ângulo Aberto , Análise da Randomização Mendeliana , Café/efeitos adversos , Estudo de Associação Genômica Ampla , Glaucoma de Ângulo Aberto/epidemiologia , Glaucoma de Ângulo Aberto/genética , Humanos , Polimorfismo de Nucleotídeo Único
3.
Exp Eye Res ; 215: 108920, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35007519

RESUMO

Prostaglandin F2α analogues (PGF2α), one of the most commonly prescribed classes of hypotensive agents, could decrease collagen fibril density and remodel the extracellular matrix in cornea. We hypothesized that PGF2α's would induce corneal softening, reduce the accuracy of intraocular pressure (IOP) measurement and lead to uncertainty in the effectiveness of the therapy. We determined the stress-strain behavior of rabbit cornea after PGF2α usage and evaluated the effect of biomechanical changes associated with PGF2α treatment on IOP measurements by Goldmann Applanation Tonometry (GAT). The tangent modulus decreased after PGF2α treatment, while the stromal interfibrillar spacing increased. PGF2α was shown to also affect the lateral eye with lower effect, which did not undergo direct eyedrop treatment. Significant decreases in the numerical predictions of GAT-IOP were predicted in all treated groups relative to control groups. Different PGF2α's (travoprost, latanoprost and bimatoprost) were associated with different extents of reduction in tissue stiffness and changes in corneal microstructure. PGF2α-induced changes in corneal mechanical properties could reduce the accuracy of IOP measurement and may cause an overestimation of the effect of PGF2α in lowering IOP, possibly leading to uncertainties in glaucoma management.


Assuntos
Dinoprosta , Prostaglandinas F Sintéticas , Amidas/farmacologia , Animais , Anti-Hipertensivos/farmacologia , Anti-Hipertensivos/uso terapêutico , Bimatoprost/farmacologia , Cloprostenol/farmacologia , Córnea , Dinoprosta/farmacologia , Pressão Intraocular , Latanoprosta/farmacologia , Prostaglandinas F Sintéticas/farmacologia , Coelhos , Tonometria Ocular , Travoprost/farmacologia
4.
Graefes Arch Clin Exp Ophthalmol ; 260(9): 2905-2911, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35488908

RESUMO

PURPOSE: To assess the acquisition rate and agreement of axial length (AL) measurements with the OA-2000, Anterion, and IOLMaster 500 in cataractous patients. METHODS: In total, 298 eyes of 191 cataractous patients were enrolled and scanned with the three devices in random order. The success rate of AL measurements per device was calculated and a chi-square test was utilized to identify the differences in acquisition rate between the three devices. Logistic regression analysis was applied to evaluate the association of different cataract types and severity with the AL measurement acquisition rate. Bland-Altman plots were mapped to appraise the agreement of AL values. RESULTS: AL measurements were successfully achieved in 288 eyes (96.64%) with the OA-2000, in 282 eyes (94.30%) with the Anteiron, and in 246 eyes (82.55%) with the IOLMaster 500. Significant differences in the acquisition rate were found between either of the SS-OCT devices and IOLMaster 500 by chi-square analysis (P < 0.001). No significant difference was noted between OA-2000 and Anterion. Increasing severity of posterior subcapsular cataract was associated with a higher failure rate with the IOLMaster 500. Bland-Altman analysis identified good agreement between the three biometers with narrow 95% limits of agreement. CONCLUSIONS: The OA-2000 and Anterion showed similarly higher acquisition rate of AL measurements than IOLMaster 500 in cataractous patients. Good agreement for AL values was found between the three biometers in cataractous patients.


Assuntos
Comprimento Axial do Olho , Catarata , Câmara Anterior , Biometria , Humanos , Interferometria , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica
5.
Graefes Arch Clin Exp Ophthalmol ; 260(7): 2271-2281, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35171331

RESUMO

PURPOSE: To investigate the repeatability of Anterion and compare the agreement of ocular biometric measurements and predicted intraocular lens (IOL) powers with other three optical biometers. METHODS: Flat keratometry (Kf), steep keratometry (Ks), J0 and 45 vectors, central cornea thickness (CCT), anterior chamber depth (ACD), and axial length (AL) from the Anterion, IOLMaster 700, Lenstar LS 900, and OA-2000 were recorded. The IOL powers were calculated with the Hoffer Q, Holladay 1, SRK/T, and Haigis formulas. The repeatability was evaluated using the within-subject standard deviation (Sw), repeatability coefficient (RC), coefficient of variation (COV), and intraclass correlation coefficient (ICC). Inter-device agreement between the four biometers was assessed with the 95% limits of agreement. RESULTS: In total, 101 right eyes of 101 participants were enrolled. The Anterion showed good repeatability for all the included biometric parameters with all the CoV ≤ 0.30% and ICC ≥ 0.930 except for J45 with moderate repeatability (ICC was 0.849). Good agreement was found among the four devices for Kf, Ks, J0, J45, ACD, and AL. Generally, wide 95% LoA was found for the predicted IOL powers with the four IOL calculation formulas between the four devices. CONCLUSIONS: The Anterion showed good repeatability of biometric measurements for most parameters. Good agreement among the four optical biometers was achieved for all the parameters except for CCT and the predicted IOL power. The AL values exhibited the best repeatability with Anterion and the best agreement among the biometers in our study.


Assuntos
Comprimento Axial do Olho , Lentes Intraoculares , Câmara Anterior/anatomia & histologia , Câmara Anterior/diagnóstico por imagem , Comprimento Axial do Olho/anatomia & histologia , Biometria , Córnea/diagnóstico por imagem , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica
6.
BMC Ophthalmol ; 22(1): 70, 2022 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-35148715

RESUMO

BACKGROUND: Congenital cataract-microcornea syndrome (CCMC) is characterized by the association of congenital cataract and microcornea without any other systemic anomaly or dysmorphism. Although several causative genes have been reported in patients with CCMC, the genetic etiology of CCMC is yet to be clearly understood. PURPOSE: To unravel the genetic cause of autosomal dominant family with CCMC. METHODS: All patients and available family members underwent a comprehensive ophthalmologic clinical examination in the hospital by expert ophthalmologists and carried out to clinically diagnosis. All the patients were screened by whole-exome sequencing and then validated using co-segregation by Sanger sequencing. RESULTS: Four CCMC patients from a Chinese family and five unaffected family members were enrolled in this study. Using whole-exome sequencing, a missense mutation c.295G > T (p.A99S, NM_003106.4) in the SOX2 gene was identified and validated by segregation analysis. In addition, this missense mutation was predicted to be damaging by multiple predictive tools. Variant p.Ala99Ser was located in a conservation high mobility group (HMG)-box domain in SOX2 protein, with a potential pathogenic impact of p.Ala99Ser on protein level. CONCLUSIONS: A novel missense mutation (c.295G > T, p.Ala99Ser) in the SOX2 gene was found in this Han Chinese family with congenital cataract and microcornea. Our study determined that mutations in SOX2 were associated with CCMC, warranting further investigations on the pathogenesis of this disorder. This result expands the mutation spectrum of SOX2 and provides useful information to study the molecular pathogenesis of CCMC.


Assuntos
Catarata , Catarata/genética , Doenças da Córnea , Análise Mutacional de DNA , Humanos , Mutação , Mutação de Sentido Incorreto , Linhagem , Fenótipo , Fatores de Transcrição SOXB1/genética
7.
BMC Ophthalmol ; 20(1): 279, 2020 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-32652982

RESUMO

BACKGROUND: To investigate the biomechanical properties of the cornea in myopic eyes using corneal visualization Scheimpflug technology (Corvis ST). The relationships between the biomechanical properties of the cornea and the degree of myopia were also investigated. METHODS: 265 eyes of 265 subjects were included. Based on spherical equivalent (SE) in diopters (D), participants were divided into four groups: low myopia/control (SE: - 0.50 to - 3.00D), moderate myopia (SE: - 3.00 to - 6.00D), high myopia (SE: - 6.00 to - 10.00D) and severe myopia (SE greater than - 10.00D). Axial length (AL), anterior segment parameters, and corneal biomechanical properties were obtained with the Lenstar LS900, Pentacam HR and Corvis ST, respectively. RESULTS: Mean (±SD) SE was - 7.29 ± 4.31D (range: - 0.63 to - 25.75D). Mean AL was 26.31 ± 1.82 mm (range: 21.87 to 31.94 mm). Significant differences were detected within the four groups in terms of six corneal biomechanical parameters: deformation amplitude (DA), time from start until second applanation (A2-time), length of flattened cornea at the second applanation (A2-length), corneal velocity during the first and second applanation (A2-velocity), time from start to highest concavity (HC-time), and central curvature at highest concavity (HC radius). AL was positively associated with DA whereas negatively associated with A1-velocity and A2-length. SE was positively associated with A2-time, HC-time and A2-velocity, whereas negatively associated with DA. IOP was positively associated with four corneal biomechanical parameters and negatively associated with three parameters. CONCLUSIONS: Eyes with severe myopia showed greater DA, lesser A2 time, HC time, and faster A2-velocity compared to low to high myopia. This suggests the cornea becomes weaker and more deformable with elongation of axial length with corresponding increases in myopia. DA, A2-time and A2-velocity could be useful corneal biomechanical indicators in patients with myopia.


Assuntos
Miopia , Tonometria Ocular , Fenômenos Biomecânicos , Córnea/diagnóstico por imagem , Humanos , Pressão Intraocular
8.
Exp Eye Res ; 161: 82-88, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28603017

RESUMO

To investigate the effects of diabetes on the biomechanical behavior of cornea in alloxan-induced diabetic rabbits. Diabetes mellitus (DM) was induced in 20 rabbits using alloxan, while another 20 age- and weight-matched non-diabetic rabbits served as controls. Eyes were enucleated after 8 weeks of inducing diabetes and the whole cornea was removed with a 3 mm wide scleral ring and tested under inflation conditions with an internal pressure range of 2.0-30.0 mmHg to determine their stress-strain behavior using an inverse analysis process. The blood glucose level (BG), advanced glycosylation end products (AGEs), central corneal thickness (CCT) and intraocular pressure (IOP) increased significantly in the DM group. There were statistically significant correlations between BG and AGEs (r = 0.768, p = 0.00), and between AGEs and CCT variation upon induction of DM (r = 0.594, p = 0.00). The tangent modulus (Et) of the cornea at four stress levels (1-4 kPa, equivalent to approximately IOP of 7.5, 15, 22.5 and 30 mmHg, respectively) was significantly higher in diabetic rabbits than in the control group (p < 0.05). Further, Et at stress of 2 kPa (which corresponded to the average IOP for the control group) was significantly correlated with BG (r = 0.378, p < 0.05), AGEs (r = 0.496, p < 0.05) and CCT variation upon induction of DM (r = 0.439, p < 0.05). IOP, as measured by contact tonometry, was also significantly correlated with both CCT (r = 0.315, p < 0.05) and Et at 2 kPa (r = 0.329, p < 0.05), and even after correcting for the effects of CCT and Et, IOP still significantly increased with both AGEs (r = 0.772, p = 0.00) and BG (r = 0.762, p = 0.00). The cornea of diabetic rabbits showed a significant increase in mechanical stiffness as evidenced by increases in corneal thickness and tangent modulus. The Et increase may be explained by a non-enzymatic cross-linking of collagen fibrils mediated by AGEs due to the high blood glucose levels in diabetes. The study also found significant IOP increases with higher blood glucose level even after controlling the effects of both corneal thickness and tangent modulus.


Assuntos
Córnea/fisiologia , Doenças da Córnea/fisiopatologia , Diabetes Mellitus Experimental/fisiopatologia , Elasticidade/fisiologia , Aloxano , Animais , Fenômenos Biomecânicos , Glicemia/metabolismo , Paquimetria Corneana , Produtos Finais de Glicação Avançada/metabolismo , Pressão Intraocular , Masculino , Coelhos , Tonometria Ocular
9.
Eye Contact Lens ; 43(2): 123-129, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26974533

RESUMO

OBJECTIVES: To evaluate the anterior segment biometry of the Tetraflex accommodating intraocular lens (AIOL) and the contribution of forward movement to the amplitude of accommodation (AMP). METHODS: Patients who underwent phacoemulsification with implantation of Tetraflex AIOLs and control nonaccommodating intraocular lenses were imaged by custom-built, long scan depth spectral-domain optical coherence tomography at relaxed and maximal accommodative states. Anterior segment biometry was performed and correlated with the clinical manifestation including AMP. RESULTS: Patients in the Tetraflex group showed better distance-corrected near visual acuity (logMAR 0.43±0.10 vs. logMAR 0.51±0.10, P<0.05) and greater AMP (1.99±0.58 diopters [D] vs. 1.59±0.45 D, P<0.05) compared with the control group. The measurement of the postoperative anterior chamber depth (ACD) during accommodation showed a forward movement of the AIOLs in 16 eyes (69.6%). Compared with the control group, a greater proportion of cases in the Tetraflex group experienced forward movement (χ test, P<0.001). The AMP in the AIOL group negatively correlated with changes in postoperative ACD during accommodation (r=-0.47, P<0.05), whereas AMP in the control group negatively correlated with postoperative pupil diameter (r=-0.57, P<0.05). CONCLUSIONS: The Tetraflex AIOLs seemed to have a tendency for forward movement; however, the slight forward axial shifts of the Tetraflex AIOL during natural accommodation may not produce a clinically relevant change in optical power.


Assuntos
Acomodação Ocular/fisiologia , Segmento Anterior do Olho/fisiologia , Biometria/métodos , Implante de Lente Intraocular , Lentes Intraoculares , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Lentes Intraoculares/normas , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Estudos Retrospectivos , Tomografia de Coerência Óptica , Acuidade Visual
10.
Ophthalmology ; 123(4): 697-708, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26826749

RESUMO

PURPOSE: To determine the effectiveness of different interventions to slow down the progression of myopia in children. METHODS: We searched MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, World Health Organization International Clinical Trials Registry Platform, and ClinicalTrials.gov from inception to August 2014. We selected randomized controlled trials (RCTs) involving interventions for controlling the progression of myopia in children with a treatment duration of at least 1 year for analysis. MAIN OUTCOME MEASURES: The primary outcomes were mean annual change in refraction (diopters/year) and mean annual change in axial length (millimeters/year). RESULTS: Thirty RCTs (involving 5422 eyes) were identified. Network meta-analysis showed that in comparison with placebo or single vision spectacle lenses, high-dose atropine (refraction change: 0.68 [0.52-0.84]; axial length change: -0.21 [-0.28 to -0.16]), moderate-dose atropine (refraction change: 0.53 [0.28-0.77]; axial length change: -0.21 [-0.32 to -0.12]), and low-dose atropine (refraction change: 0.53 [0.21-0.85]; axial length change: -0.15 [-0.25 to -0.05]) markedly slowed myopia progression. Pirenzepine (refraction change: 0.29 [0.05-0.52]; axial length change: -0.09 [-0.17 to -0.01]), orthokeratology (axial length change: -0.15 [-0.22 to -0.08]), and peripheral defocus modifying contact lenses (axial length change: -0.11 [-0.20 to -0.03]) showed moderate effects. Progressive addition spectacle lenses (refraction change: 0.14 [0.02-0.26]; axial length change: -0.04 [-0.09 to -0.01]) showed slight effects. CONCLUSIONS: This network analysis indicates that a range of interventions can significantly reduce myopia progression when compared with single vision spectacle lenses or placebo. In terms of refraction, atropine, pirenzepine, and progressive addition spectacle lenses were effective. In terms of axial length, atropine, orthokeratology, peripheral defocus modifying contact lenses, pirenzepine, and progressive addition spectacle lenses were effective. The most effective interventions were pharmacologic, that is, muscarinic antagonists such as atropine and pirenzepine. Certain specially designed contact lenses, including orthokeratology and peripheral defocus modifying contact lenses, had moderate effects, whereas specially designed spectacle lenses showed minimal effect.


Assuntos
Atropina/administração & dosagem , Óculos , Midriáticos/administração & dosagem , Miopia/prevenção & controle , Comprimento Axial do Olho/fisiologia , Bases de Dados Factuais , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Refração Ocular/fisiologia , Resultado do Tratamento
11.
Zhonghua Yan Ke Za Zhi ; 52(1): 47-50, 2016 Jan.
Artigo em Zh | MEDLINE | ID: mdl-26899221

RESUMO

OBJECTIVE: To objectively assess and compare comprehensive optical quality among adults at different ages. METHODS: In this cross-sectional study, there were 432 subjects (432 eyes) aged from 20 to 70 years with best corrected visual acuity (BCVA) better than 4.9. If both eyes of a subject had equal BCVA, one eye was selected randomly. Otherwise, the eye with better BCVA was chosen. The patients were divided into 5 groups at an age interval of 10 years. The optical quality analysis system Ⅱ (OQASⅡ) was used to measure the following optical quality parameters: the modulation transfer function cutoff frequency (MTFcutoff), the Strehl ratio, three OQAS values (OV100%, OV20%, and OV9%), and the objective scatter index (OSI). Each optical quality parameter was compared among different groups by One-way ANOVA. RESULTS: In the groups of 20-29 years, 30-39 years, 40-49 years, 50-59 years, and 60-69 years, the MTFcutoff was (43.91±7.43), (40.93±9.92), (37.16±9.04), (36.69±7.87), and (28.52±8.31) cpd, respectively; the Strehl ratio was 0.26±0.06, 0.24±0.06, 0.20±0.05, 0.20±0.04, and 0.16±0.04, respectively; the OV100% was 1.47±0.24, 1.36±0.33, 1.24±0.30, 1.22±0.26, and 0.96±0.28, respectively; the OV20% was 1.51±0.33, 1.40±0.38, 1.22±0.36, 1.20±0.28, and 0.91±0.32, respectively; the OV9% was 1.14±0.26, 1.41±0.40, 1.20± 0.37, 1.18±0.28, and 0.89±0.28, respectively; the OSI was 0.42±0.24, 0.53±0.32, 0.54±0.34, 0.54±0.26, and 1.06±0.56, respectively. There were significant differences in the mean values of MTFcutoff, Strehl ratio, OV100%, and OV20% among groups (P<0.05), except for the groups of 40-49 years and 50-59 years (P>0.05). The OV9% was significantly different among groups (P<0.05), except for the groups of 20-29 years, 40-49 years, and 50-59 years (P>0.19). The OSI was also significantly different among groups (P<0.05), except for the groups of 30-39 years, 40-49 years, and 50-59 years (P>0.70). CONCLUSION: The comprehensive optical quality in the young healthy population is better than the old, except for a plateau in the middle-aged population.


Assuntos
Fatores Etários , Visão Ocular/fisiologia , Acuidade Visual/fisiologia , Adulto , Idoso , Estudos Transversais , Humanos , Pessoa de Meia-Idade , Adulto Jovem
12.
Exp Eye Res ; 137: 11-7, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26026878

RESUMO

The relationship of corneal biomechanical metrics provided by the Ocular Response Analyzer (ORA) and Corvis ST (CVS) with physical intraocular pressure (IOPp) and central corneal thickness (CCT) was evaluated. Thirty fresh enucleated eyes of 30 rabbits were used in ex vivo whole globe inflation experiments. IOPp was measured with a pressure transducer and increased from 7.5 to 37.5 mmHg in steps of 7.5 mmHg while biomechanical data was acquired using the ORA and CVS. At least 3 examinations were performed at each pressure level, where CCT and twelve biomechanical metrics were recorded and analyzed as a function of IOPp. The biomechanical metrics included corneal hysteresis (CH) and corneal resistance factor (CRF), obtained by the ORA. They also included the applanation times (A1T, A2T), lengths (A1L, A2L) and velocities (A1V, A2V), in addition to the highest concavity time (HCT), peak distance (PD), radius (HR) and deformation amplitude (DA), obtained by the CVS. The variation of CCT and the twelve biomechanical metrics for the 30 rabbit eyes tested across the 5 pressure stages considered (inter-pressure differences) were statistically significant (P = 0.00). IOPp was highly to moderately correlated with most biomechanical metrics, especially CRF, A1T, A1V, A2V, PD and DA, while the relationships with CH, A2T, A1L and HCT were poor. IOP has important influences on most corneal biomechanical metrics provided by CVS and ORA. Two biomechanical metrics A1V and HR were influenced by CCT after correcting for the effect of IOP in most pressure stages, while the correlation with others were weak. Comparisons of research groups based on ORA and CVS with different IOPs and CCTs may lead to possible misinterpretations if both or one of which are not considered in the analysis.


Assuntos
Córnea/fisiopatologia , Glaucoma de Ângulo Aberto/fisiopatologia , Pressão Intraocular/fisiologia , Animais , Fenômenos Biomecânicos , Córnea/patologia , Modelos Animais de Doenças , Glaucoma de Ângulo Aberto/diagnóstico , Coelhos , Tonometria Ocular
13.
Lasers Surg Med ; 47(9): 698-703, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26311629

RESUMO

BACKGROUND AND OBJECTIVE: Femtosecond laser-assisted cataract surgery (FLACS) is rapidly gaining popularity due to the improved consistency and predictability for capsulorhexis. This study aimed to investigate the preliminary clinical outcomes of FLACS with a noncontact femtosecond laser system. PATIENTS AND METHODS: This prospective study enrolled 25 eyes in the trial group underwent FLACS (LLS-fs 3D, LENSAR, USA), and 29 eyes in the control group underwent conventional cataract surgery (Stellaris, Bausch & Lomb, USA). The phacoemulsification time, energy, and complications during operation were recorded. Postoperative refraction at 1 day, 1 week, 1 and 3 months, the capsulorhexis size and corneal endothelial density at 1 and 3 months were also measured. RESULTS: Compared to the control group, reduction in phacoemulsification time was 51.5% (P = 0.02), and in overall energy, 65.1% (P = 0.02) in the trial group. In the trial group and the control group, total time of cataract procedure was 10.04 ± 1.37 minutes, 10.52 ± 1.92 minutes, respectively (P = 0.31); the absolute difference between attempted and achieved capsulorhexis diameter at 1 month was 192.9 ± 212.0 µm, 626.9 ± 656.6 µm, respectively (P = 0.04), and at 3 months, 256.6 ± 181.9 µm, 572.1 ± 337.0 µm, respectively (P= 0.03); the absolute difference between attempted and achieved spherical equivalent at 3 months was 0.16 ± 0.16 D, 0.74 ± 0.65 D, respectively (P < 0.01); mean corneal endothelial cell loss at 1 month was 15.6% and 14.2%, respectively (P = 0.77), and at 3 months, 2.9%, 4.2%, respectively (P = 0.50). CONCLUSIONS: With the noncontact femtosecond laser system, FLACS can significantly improve the accuracy and repeatability of capsulorhexis, reduce the phacoemulsification time and overall energy, and enhance the predictability and stability of postoperative refraction.


Assuntos
Extração de Catarata/instrumentação , Catarata/patologia , Terapia a Laser/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Endotélio Corneano/patologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Acuidade Visual
14.
Zhonghua Yan Ke Za Zhi ; 51(3): 206-9, 2015 Mar.
Artigo em Zh | MEDLINE | ID: mdl-26268644

RESUMO

OBJECTIVE: To study the effects of posterior chamber phakic intraocular lens (IOL) on axial length (AL) measurements and whether a correction factor for later IOL power calculation before cataract surgery is necessary. METHODS: Twenty-two high myopic patients (39 eyes) with mean spherical equivalent -19.00 +/- 4.03 D received phakic refractive lens (PRL) implantation, and 24 patients (40 eyes) with mean spherical equivalent (-13.10 +/- 2.53) D received implantable Collamer lens (ICL) implantation. Pre-and postoperative AL measurements with the IOLMaster were compared. Results The pre-and postoperative ALs were (30.87 +/- 2.18) mm and (30.94 +/- 2.16) mm, respectively (t = -2.635, P = 0.012) in the PRL group, and (28.35 +/- 1.20) mm and (28.45 +/- 1.22) mm, respectively ( t = -3.97, P < 0.001) in the ICL group. Linear regression analysis showed: in the PRL group, preoperative AL = 1.01 x postoperative AL-0.24 (R2 = 0.99, P < 0.001), or postoperative AL--preoperative AL = 0.24-0.0055 x postoperative AL; in the ICL group, preoperative AL = 0.96 x postoperative AL +1.17 (R2 = 0.99, P < 0.001), or postoperative AL--preoperative AL = 0.0154 x postoperative AL -0.3763. The mean differences between pre-and postoperative ALs in the PRL and, ICL groups were 0.075 mm and 0.054 mm, respectively. CONCLUSIONS: Based on the SRK formula, a < 0.1 mm AL difference would result in a <0.25 D change in the calculated IOL power, possibly a < 0.20 D change in manifest refraction. Furthermore, for PRL, the longer the AL, the smaller the difference between pre-and postoperative ALs. These differences are so small that it is unnecessary to correct IOL power calculation.


Assuntos
Extração de Catarata , Olho/anatomia & histologia , Implante de Lente Intraocular , Miopia/terapia , Lentes Intraoculares Fácicas , Humanos , Lentes Intraoculares , Modelos Lineares , Assistência Perioperatória , Período Pós-Operatório , Testes Visuais , Acuidade Visual
15.
Int J Ophthalmol ; 17(3): 466-472, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38721508

RESUMO

AIM: To investigate the molecular diagnosis of a three-generation Chinese family affected with aniridia, and further to identify clinically a PAX6 missense mutation in members with atypical aniridia. METHODS: Eleven family members with and without atypical aniridia were recruited. All family members underwent comprehensive ophthalmic examinations. A combination of whole exome sequencing (WES) and direct Sanger sequencing were performed to uncover the causative mutation. RESULTS: Among the 11 family members, 8 were clinically diagnosed with congenital aniridia (atypical aniridia phenotype). A rare heterozygous mutation c.622C>T (p.Arg208Trp) in exon 8 of PAX6 was identified in all affected family members but not in the unaffected members or in healthy control subjects. CONCLUSION: A rare missense mutation in the PAX6 gene is found in members of a three-generation Chinese family with congenital atypical aniridia. This result contributes to an increase in the phenotypic spectrum caused by PAX6 missense heterozygous variants and provides useful information for the clinical diagnosis of atypical aniridia, which may also contribute to genetic counselling and family planning.

16.
J Refract Surg ; 40(7): e438-e444, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39007810

RESUMO

PURPOSE: To assess the influence of ocular biometric parameters on intraocular lens (IOL) tilt and decentration after cataract surgery. METHODS: Patients scheduled for cataract surgery were screened for inclusion in this prospective cohort study. Tilt and decentration of the crystalline lens and IOL were measured using the CASIA2 (Tomey). Anterior chamber depth (ACD), lens thickness (LT), and axial length (AL) were preoperatively measured by the IOLMaster 700 (Carl Zeiss Meditec AG). Multivariate regression analysis was performed to assess the influence of ocular biometric parameters on IOL tilt and decentration after cataract surgery. RESULTS: In total, 191 eyes of 120 patients were included. Age was positively correlated with IOL tilt, whereas ACD and AL were negatively correlated with IOL tilt. A strong positive correlation was found between preoperative crystalline lenses and postoperative IOLs in tilt magnitude (r = 0.769, P < .001) and tilt direction (r = 0.688, P < .001). A positive correlation was found between preoperative and postoperative lens decentration magnitude and decentration direction. Greater postoperative IOL tilt and decentration were significantly associated with greater preoperative crystalline lens tilt (P < .001) and decentration (P = .027). CONCLUSIONS: IOL tilt was greater in older patients. Shorter AL and shallower ACD contributed to greater IOL tilt. The tilt and decentration of the IOL will be greater in patients with greater tilt and decentration of the crystalline lens. [J Refract Surg. 2024;40(7):e438-e444.].


Assuntos
Comprimento Axial do Olho , Biometria , Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Humanos , Estudos Prospectivos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Comprimento Axial do Olho/patologia , Idoso de 80 Anos ou mais , Câmara Anterior/patologia , Migração do Implante de Lente Intraocular/fisiopatologia , Cristalino , Acuidade Visual/fisiologia , Adulto , Pseudofacia/fisiopatologia
17.
Am J Ophthalmol ; 265: 200-212, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38719132

RESUMO

PURPOSE: To investigate the repeatability and agreement of corneal astigmatism measurements in eyes with irregular corneal astigmatism component (ICAC) using four devices: IOLMaster 700 biometer, Lenstar 900 biometer, iTrace, and Pentacam. DESIGN: Prospective cross-sectional reliability analysis. METHODS: Sixty-four eyes (52 patients) with ICAC were examined three times using the four devices. The eye with ICAC in this study is defined as the cornea has a certain degree of irregular astigmatism (asymmetric and/or skewed bowtie pattern of corneal topography according to corneal topography classification), accompanied with total corneal higher-order aberrations in the 4 mm zone of 0.3 µm or greater. Corneal astigmatism was evaluated using three categories: anterior corneal astigmatism (ACA), posterior corneal astigmatism, and total corneal astigmatism (TCA). The repeatability was determined using the ∆Ast (arithmetic mean of vector differences among three repeated corneal astigmatism measurements). Bland-Altman plots and astigmatism vector analyses were employed to assess agreement. RESULTS: The IOLMaster 700 (∆Ast = 0.27 ± 0.20 D) showcased higher repeatability in ACA measurements compared to iTrace (∆Ast = 0.37 ± 0.38 D, P = .040) and Pentacam (∆Ast = 0.50 ± 0.22 D, P < .001), and paralleled the performance of Lenstar 900 (∆Ast = 0.31 ± 0.26 D, P = .338). The Pentacam (∆Ast = 0.09 ± 0.07 D, P < .001) demonstrated superior repeatability in posterior corneal astigmatism, whereas the IOLMaster 700 (∆Ast = 0.33 ± 0.23 D, P < .001) excelled in TCA. The IOLMaster 700 exhibited good agreement with either Lenstar 900 or iTrace, characterized by narrow 95% limits of agreement and clinically acceptable vector differences. Conversely, vector differences between Pentacam and the other three devices in ACA and TCA measurements were clinically significant, exceeding 0.50 D (all P < .05). CONCLUSIONS: In terms of repeatability of corneal astigmatism measurements in eyes with ICAC, the IOLMaster 700 and Lenstar 900 outperformed iTrace and Pentacam. While the IOLMaster 700 can be used interchangeably with either Lenstar 900 or iTrace, the Pentacam is not interchangeable with the other three devices.

18.
J Refract Surg ; 39(1): 48-55, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36630430

RESUMO

PURPOSE: To investigate refractive prediction accuracy with the OA-2000 (Tomey), Anterion (Heidelberg Engineering), and IOLMaster 500 (Carl Zeiss Meditec AG) in patients with cataract. METHODS: Patients with cataract referred for phacoemulsification were enrolled and scanned with the OA-2000, Anterion, and IOLMaster 500 in random order. The success rate of axial length (AL) measurements per device was calculated and a chi-square test was used to identify the differences in acquisition rate between the three devices. The Bland-Altman method was used to appraise the agreement of biometric parameters between the three devices. Four different formulas (Barrett Universal II [BUII], Haigis, Holladay 1, and SRK/T) were included in the study. The parameters of refractive prediction accuracy comprised predictive error (PE), absolute PE (AE), and percentages of eyes with a PE within ±0.50, ±0.75, and ±1.00 diopters (D). RESULTS: The acquisition rates of AL measurements with the OA-2000 and Anterion were 97.35% and 94.70%, respectively (chi-square = 3.82, P > .05). A significantly lower acquisition rate of 84.82% was obtained with the IOLMaster 500 compared with the other two devices (P < .05). Bland-Altman analysis identified good agreement between the three biometers with narrow 95% limits of agreement for flat and steep keratometry (K1 and K2), anterior chamber depth (ACD), and AL. For PE, only the differences between the Anterion and IOLMaster 500 with the Barrett UII and Haigis formulas were statistically significant (P < .05). The three devices revealed no statistically significant differences in MAE, MedAE, and the proportion of eyes with a PE within ±0.50, ±0.75, and ±1.00 D (P > .05). CONCLUSIONS: The OA-2000 and Anterion showed a similarly higher acquisition rate of AL measurements than the IOLMaster 500 in patients with cataract. Good agreement for K1, K2, ACD, and AL was found between the three biometers. Regarding refractive prediction accuracy, the Anterion did not significantly outperform both the OA-2000 and IOLMaster 500. [J Refract Surg. 2023;39(1):48-55.].


Assuntos
Extração de Catarata , Catarata , Lentes Intraoculares , Dispositivos Ópticos , Facoemulsificação , Humanos , Refração Ocular , Catarata/diagnóstico , Facoemulsificação/métodos , Biometria/métodos , Óptica e Fotônica , Comprimento Axial do Olho , Estudos Retrospectivos
19.
Eye Vis (Lond) ; 10(1): 16, 2023 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-37005660

RESUMO

BACKGROUND: To assess the effect of tear film instability in dry eye disease (DED) by measuring visual performance and tear film optical quality in a simultaneous real-time analysis system. METHODS: Thirty-seven DED participants and 20 normal controls were recruited. A simultaneous real-time analysis system was developed by adding a functional visual acuity (FVA) channel to a double-pass system. Repeated measurements of FVA and objective scatter index (OSI) were performed simultaneously with this system under blink suppression condition for 20 s. Patient-reported symptoms was evaluated using the Ocular Surface Disease Index (OSDI) questionnaire. Mean FVA, mean OSI, and visual acuity break-up time were defined. The OSI maintenance ratio was calculated as an evaluation index to assess the difference between dynamic OSI changes and baseline OSI. The visual maintenance ratio was also calculated in the same way. RESULTS: Moderate correlations were noted between mean OSI and FVA-related parameters (mean FVA, visual maintenance ratio, visual acuity break-up time: 0.53, - 0.56, - 0.53, respectively, P < 0.01 for all). Moderate to high correlations were noted between OSI maintenance ratio and FVA-related parameters (mean FVA, visual maintenance ratio, visual acuity break-up time: - 0.62, 0.71, 0.64, respectively, all P < 0.01). The metrics derived from the simultaneous real-time analysis system were moderately correlated with the patient-reported symptoms and the visual acuity break-up time possessed the highest correlation coefficients with OSDI total, ocular symptoms, and vision-related function (- 0.64, - 0.63, - 0.62, respectively, P < 0.01). The OSI-maintenance ratio alone appeared to exhibit the best performance of the metrics for the detection of DED with sensitivity of 95.0% and specificity of 83.8% and the combinations of FVA parameters and OSI parameters were valid and can further improve the discriminating abilities. CONCLUSIONS: OSI-related metrics were found to be potential indicators for assessing and diagnosing DED which correlated with both subjective visual performance and patient-reported symptoms; the FVA-related metrics were quantifiable indicators for evaluating visual acuity decline in DED. TRIAL REGISTRATION NUMBER: Chinese Clinical Trial Registry, ChiCTR2100051650. Registered 29 September 2021, https://www.chictr.org.cn/showproj.aspx?proj=134612.

20.
Transl Vis Sci Technol ; 12(12): 6, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-38054930

RESUMO

Purpose: To investigate the feasibility and efficacy of a continuous functional contrast visual acuity (CFCVA) system in the assessment of visual function in dry eye disease (DED). Methods: Twenty patients with DED and 15 normal controls were recruited. Subjective symptoms were evaluated using the Ocular Surface Disease Index (OSDI) questionnaire, and tear film stability was assessed by a noninvasive corneal topographer. Under natural blinking conditions, the custom-built CFCVA system was used to take serial visual acuity measurements at 100%, 25%, 10%, and 5% contrast for 60 seconds. A 5-minute measurement at a 100% contrast level was defined as the stress test (ST). Mean CFCVA was defined, and visual maintenance ratio (VMR) was the ratio of mean CFCVA divided by baseline visual acuity. Results: In both groups, VMR decreased and mean CFCVA (logarithm of the minimum angle of resolution) increased with decreasing optotype contrast (from 100% to 5%). In ST, the ST VMR at the fourth and fifth minutes (VMR54 and VMR55) showed the strongest correlations with OSDI total, ocular symptoms, and vision-related function (-0.646 and -0.598, -0.688 and -0.693, and -0.599 and -0.555, respectively, P < 0.05). VMR54 and VMR55 also demonstrated the best discriminating ability for detecting DED, with areas under the curve of 0.903 and 0.867, respectively. Conclusions: Extending the continuous measuring time was more effective for detecting vision-related functional abnormalities in patients with DED than simply decreasing the optotype contrast level. Translational Relevance: The proposed CFCVA system and associated parameters offer a potential method for quantifying and interpreting the visual symptoms of DED in clinical care.


Assuntos
Síndromes do Olho Seco , Humanos , Acuidade Visual , Síndromes do Olho Seco/diagnóstico , Olho
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa