Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Med ; 13(11)2024 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-38892822

RESUMO

Objective: To examine the surgical, audiological and patient-reported outcomes of the Osia 2 implant. Methods: Data from 14 consecutive subjects undergoing implantation between April 2022 and November 2023 were reviewed. Ten subjects had conductive hearing loss, three had mixed hearing loss and one had single-sided deafness (SSD). Warble tone thresholds, Pure Tone Average (PTA4) and Speech Discrimination Score (SDS) in quiet and in noise were determined unaided and aided. The subjective outcome was determined from two standardized questionnaires: (1) International Outcome Inventory for Hearing Aids (IOI-HA) and (2) Speech, Spatial and Qualities of Hearing Scale 12 (SSQ12b). Results: Unexpected postoperative pain was found in four cases. The warble tone thresholds exhibited a consistent reduction across all frequencies, contributing to a mean decrease of 27 dB in the aided PTA4. SDS demonstrated notable improvements, with a 57.3% increase at 50 dB and a 55.6% increase at 65 dB. In noise, SDS exhibited a 43.9% improvement. The mean IOI-HA Score was 3.8, and the mean overall score for SSQ12b was 6.6, with consistent findings across the subgroups. Conclusions: The Osia device emerges as a promising recommendation for individuals with conductive or mixed hearing loss, possibly also for those with SSD. Its safety and efficacy profile aligns with the broader category of active transcutaneous devices, demonstrating a reduced risk of wound infection compared to percutaneous alternatives. Both audiological assessments and subjective evaluations revealed positive outcomes.

2.
Hear Res ; 446: 109005, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38598943

RESUMO

Auditory nerve (AN) fibers that innervate inner hair cells in the cochlea degenerate with advancing age. It has been proposed that age-related reductions in brainstem frequency-following responses (FFR) to the carrier of low-frequency, high-intensity pure tones may partially reflect this neural loss in the cochlea (Märcher-Rørsted et al., 2022). If the loss of AN fibers is the primary factor contributing to age-related changes in the brainstem FFR, then the FFR could serve as an indicator of cochlear neural degeneration. In this study, we employed electrocochleography (ECochG) to investigate the effects of age on frequency-following neurophonic potentials, i.e., neural responses phase-locked to the carrier frequency of the tone stimulus. We compared these findings to the brainstem-generated FFRs obtained simultaneously using the same stimulation. We conducted recordings in young and older individuals with normal hearing. Responses to pure tones (250 ms, 516 and 1086 Hz, 85 dB SPL) and clicks were recorded using both ECochG at the tympanic membrane and traditional scalp electroencephalographic (EEG) recordings of the FFR. Distortion product otoacoustic emissions (DPOAE) were also collected. In the ECochG recordings, sustained AN neurophonic (ANN) responses to tonal stimulation, as well as the click-evoked compound action potential (CAP) of the AN, were significantly reduced in the older listeners compared to young controls, despite normal audiometric thresholds. In the EEG recordings, brainstem FFRs to the same tone stimulation were also diminished in the older participants. Unlike the reduced AN CAP response, the transient-evoked wave-V remained unaffected. These findings could indicate that a decreased number of AN fibers contributes to the response in the older participants. The results suggest that the scalp-recorded FFR, as opposed to the clinical standard wave-V of the auditory brainstem response, may serve as a more reliable indicator of age-related cochlear neural degeneration.


Assuntos
Estimulação Acústica , Envelhecimento , Audiometria de Resposta Evocada , Cóclea , Nervo Coclear , Potenciais Evocados Auditivos do Tronco Encefálico , Degeneração Neural , Humanos , Feminino , Cóclea/fisiopatologia , Cóclea/inervação , Adulto , Idoso , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Fatores Etários , Nervo Coclear/fisiopatologia , Envelhecimento/fisiologia , Eletroencefalografia , Audiometria de Tons Puros , Limiar Auditivo , Presbiacusia/fisiopatologia , Presbiacusia/diagnóstico , Valor Preditivo dos Testes , Fatores de Tempo
3.
Otol Neurotol ; 45(2): 128-135, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38206060

RESUMO

BACKGROUND AND OBJECTIVE: Intralabyrinthine schwannomas (ILSs) may have detrimental effects on ipsilateral hearing, commonly leading to single-sided deafness (SSD). Cochlear implantation in patients with ILSs is an option to partly restore ipsilateral hearing; however, the available literature fails to account for the binaural hearing benefits of a cochlear implant (CI) for ILSs. METHODS: We prospectively evaluated SSD patients with sporadic ILS undergoing cochlear implantation with simultaneous tumor resection (n = 10) or with tumor observation (n = 1). Patients completed the Speech, Spatial and Qualities Questionnaire (SSQ12) and the Nijmegen Cochlear Implant Questionnaire (NCIQ) pre- and postoperatively, as well as the Bern Benefit in Single-Sided Deafness (BBSSD) questionnaire postoperatively. Patients were also tested postoperatively with and without their CI to measure the effect on localization ability and binaural summation, squelch, and head shadow. RESULTS: Evaluation was completed for nine and six patients (subjective and objective data, respectively). The CI significantly improved the speech reception threshold (SRT) in the head shadow condition where the target signal was presented to the CI side and the noise to the front (SCIN0). On the other hand, the SRTs in the colocated condition (S0N0) and the condition where the target signal was presented to the front and the noise to the CI side (S0NCI) were unaffected by the CI. The mean localization error decreased significantly from 102° to 61° (p = 0.0031) with the addition of a CI. The scores from SSQ12 demonstrated nonsignificant changes. For NCIQ, the self-esteem and the social interaction domains increased significantly but insignificantly for the remaining domains. The BBSSD responses ranged from +0.5 to +3.5 points. CONCLUSION: After implantation, patients achieved significantly better scores across some of the patient-reported and objective parameters. In addition to reporting on a number of ILS cases where implantation was performed, the study is the first of its kind to document patient-reported and objective binaural hearing improvement after cochlear implantation in patients with ILS and, thereby, lends support to the active management of ILS.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Neurilemoma , Humanos , Audição
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA