1.
Transfusion ; 58(5): 1100-1107, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29574766

RESUMO

BACKGROUND: Di(2-ethylhexyl)phthalate (DEHP) makes polyvinyl chloride flexible for use in blood bags and stabilizes the red blood cell (RBC) membrane preventing excessive hemolysis. DEHP migrates into the blood product and rodent studies have suggested that DEHP exposure may be associated with adverse health effects albeit at high dosages. Although structurally and functionally similar to DEHP, di(2-ethylhexyl)terephthalate (DEHT; or Eastman 168 SG [Eastman Chemical Company]) is metabolically distinct with a comprehensive and benign toxicology profile. This study evaluated RBC stability in DEHT-plasticized bags with AS-1 and PAGGSM compared to conventional DEHP-plasticized bags with AS-1. STUDY DESIGN AND METHODS: Thirty-six whole blood units were collected into CPD solution, leukoreduced, centrifuged, and divided into RBCs and plasma. To limit donor-related variability, three ABO-identical RBCs were mixed together and then divided equally and stored among the three different plasticizer and additive solution combinations. RBCs from 12 trios were analyzed for a standard panel of in vitro variables on Day 0 and after storage. RESULTS: No individual bag on Day 42 exceeded the US 1.0% hemolysis criteria. While hemolysis during storage was higher in the DEHT bags, the PAGGSM RBCs were close to the control RBCs (0.38% vs. 0.32%, respectively). ATP retention was higher than 70% and potassium levels were similar regardless of plasticizer. Additional RBC variables exhibited some significant differences but were not viewed as clinically important. CONCLUSION: DEHT/PAGGSM provides similar hemolysis protection to that of DEHP/AS-1. Although hemolysis values with DEHT and AS-1 are higher than that of DEHP, DEHT is a potential DEHP alternative.


Assuntos
Preservação de Sangue/métodos , Eritrócitos/citologia , Plastificantes/química , Embalagem de Produtos/métodos , Soluções/química , Adenina , Glucose , Guanosina , Hemólise/efeitos dos fármacos , Humanos , Manitol , Ácidos Ftálicos , Cloreto de Polivinila , Cloreto de Sódio
2.
Cytometry B Clin Cytom ; 94(5): 651-657, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29476701

RESUMO

The BD FACSVia™ system is a novel flow cytometer with improved workflow efficiencies. To evaluate the HLA-B27 application developed on the BD FACSVia system utilizing the BD™ HLA-B27 kit, we conducted a concordance study at three centers to compare with the BD FACSCalibur™ system. Prepared donor samples (n = 594) were analyzed on both the BD FACSVia and BD FACSCalibur for the HLA-B27 assay. Adjudication of HLA-B27 discordant results was performed using the reverse sequence-specific oligonucleotide (rSSO) DNA typing method (LABType® SSO, One Lambda). On the BD FACSVia system 80 B27 positive, 499 B27 negative and 15 "Inconclusive" samples were observed. The corresponding BD FACSCalibur results were 73 B27 positive, 502 B27 negative and 19 "gray zone" samples. The overall concordance of HLA-B27 determination was 98% between the two systems with seven more positives identified on BD FACSVia as compared to BD FACSCalibur. The equivocal zone between positive and negative on BD FACSVia (named "Inconclusive") and on BD FACSCalibur (named "gray zone") is due to antibody cross reactivity of HLA-B27 clone GS145.2. One negative sample verified with the rSSO DNA method was reported as HLA-B27 positive by the BD FACSVia system leading to a false positive result. Our study demonstrated concordance results between the BD FACSVia system and BD FACSCalibur. Intersite reproducibility of BD HLA-B27 assay remained within the limits of acceptability. © 2018 The Authors. Cytometry Part B: Clinical Cytometry published by Wiley Periodicals, Inc. on behalf of International Clinical Cytometry Society.


Assuntos
Citometria de Fluxo/normas , Antígeno HLA-B27/sangue , Kit de Reagentes para Diagnóstico/normas , Reações Falso-Positivas , Humanos , Sensibilidade e Especificidade
3.
Cytometry A ; 93(4): 420-426, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29345745

RESUMO

The BD FACSVia™ System features novel designs in hardware, software, and instrument QC. We compared the performance of the BD FACSVia System using the BD Leucocount™ kit with the BD FACSCalibur™ flow cytometer. Leucoreduced platelet (PLT, n = 252) and red blood cell (RBC, n = 278) specimens were enrolled at four sites. Each specimen was stained in four tubes using the BD Leucocount kit reagents and acquired on the two systems. BD Leucocount Control cells (high and low) were used to evaluate the inter-site reproducibility on the BD FACSVia System at three sites over 20 days. Deming regression and Bland-Altman analysis were performed to determine the WBC absolute counts on the BD FACSVia System vs. the BD FACSCalibur system. Assay accuracy for the range of 0-350 WBCs/µl was adequate. For samples with <25 WBCs/µl, the bias with 95% limits of agreement was 0.136 (-1.897 to 2.169) WBC/µl for PLTs (n = 184) and 0.170 (-2.025 to 2.365) WBC/µl for RBCs (n = 193). For inter-site reproducibility, the CV% was 6.46% (upper 95% CI 7.16%) for the PLT high control and 9.49% (10.52%) for the PLT low control. The CV% was 7.51% (8.32%) for the RBC high control and 10.76% (11.92%) for the RBC low control. The BD FACSVia System reported equivalent results of WBC absolute counts for leucoreduced PLT and RBC samples compared to the BD FACSCalibur system. The inter-laboratory reproducibility of the BD FACSVia System met study specifications. © 2018 The Authors. Cytometry Part A Published by Wiley Periodicals, Inc. on behalf of ISAC.


Assuntos
Eritrócitos/citologia , Citometria de Fluxo/métodos , Leucócitos/citologia , Plaquetas/citologia , Humanos , Contagem de Leucócitos/métodos , Contagem de Plaquetas/métodos , Reprodutibilidade dos Testes