Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Expert Rev Mol Diagn ; 20(12): 1253-1258, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32893699

RESUMO

OBJECTIVES: Accurate assays for hepatitis C virus (HCV) quantitation and genotyping are important for the management of HCV infection. In this study, we evaluated the performance of cobas HCV and cobas HCV GT assays (Roche) for HCV quantitation and genotyping on the cobas 4800 System. METHODS: We compared the performance of the cobas HCV assays with another commercial system (Abbott m2000) using a panel of well-characterized patient samples and proficiency testing samples. RESULTS: The limit-of-detection of the cobas HCV assay in our center was higher (15 IU/mL) than the manufacturer claim (9.2 IU/mL). The assay showed high analytical specificity, accuracy, precision, and linearity. Performance was congruent with the RealTime HCV assay (Abbott). For genotyping, the cobas HCV GT assay only showed moderate agreement with the RealTime HCV Genotype II assay (kappa = 0.550). The cobas assay outperformed the RealTime assay for typing HCV genotypes 1b and 6 (p = 0.033). CONCLUSION: Our results confirm that the cobas 4800 System is a reliable platform for HCV quantitation and genotyping. The cobas HCV GT assay is a good choice for genotype 1b/6 endemic areas in east Asia, clearly outperforming the RealTime HCV Genotype II assay.


Assuntos
Genótipo , Técnicas de Genotipagem , Hepacivirus/genética , Hepatite C/diagnóstico , Hepatite C/virologia , Técnicas de Genotipagem/métodos , Técnicas de Genotipagem/normas , Humanos , RNA Viral , Kit de Reagentes para Diagnóstico , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Carga Viral
2.
Biomed Res Int ; 2019: 5715180, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31687393

RESUMO

Several commercial PCR kits are available for detection of herpes simplex virus (HSV) and varicella zoster virus (VZV), but the test performance of one CE-marked in vitro diagnostic kit-RealStar® alpha Herpesvirus PCR Kit-has not been well studied. This study evaluated the performance of RealStar® alpha Herpesvirus PCR Kit 1.0 on the LightCycler® 480 Instrument II for detection and differentiation of HSV-1, HSV-2, and VZV in human clinical specimens. We evaluated the analytical sensitivity of the RealStar® and in-house multiplex real-time PCR assays using serial dilutions of nucleic acids extracted from clinical specimens. The analytical sensitivity of the RealStar® assay was 10, 32, and 100 copies/reaction for HSV-1, HSV-2, and VZV, respectively, which was slightly higher than that of the in-house multiplex real-time PCR assay. Reproducibility of the cycle threshold (Cp) values for each viral target was satisfactory with the intra- and interassay coefficient of variation values below 5% for both assays. One-hundred and fifty-three clinical specimens and 15 proficiency testing samples were used to evaluate the diagnostic performance of RealStar® alpha Herpesvirus PCR Kit against the in-house multiplex real-time PCR assay. The RealStar® assay showed 100% sensitivity and specificity when compared to the in-house assay. Cp values of the RealStar® and in-house assays showed excellent correlation. RealStar® alpha Herpesvirus PCR is a sensitive, specific, and reliable assay for the detection of HSV-1, HSV-2, and VZV, with less extensive verification requirements compared to a laboratory developed assay.


Assuntos
Herpesvirus Humano 1/genética , Herpesvirus Humano 2/genética , Herpesvirus Humano 3/genética , Reação em Cadeia da Polimerase Multiplex/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos , DNA Viral/genética , Herpes Simples/virologia , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Virol J ; 15(1): 149, 2018 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-30261891

RESUMO

BACKGROUND: Human adenoviruses are common causes of community-acquired respiratory tract and enteric infections. Severe disseminated infections with high mortality rates may be seen in immunocompromised individuals. An accurate and cost-effective quantitative assay is essential not only for laboratory diagnosis of adenoviral infections, but also for monitoring of response to antiviral treatment. The diagnostic performance of an in-house quantitative polymerase chain reaction assay was compared to a commercial system. METHODS: The analytical sensitivity, specificity, linearity, precision and accuracy of an in-house adenovirus quantitative polymerase chain reaction assay were evaluated against the RealStar® Adenovirus PCR Kit (Altona Diagnostics GmbH, Hamburg, Germany), using 122 clinical specimens and 18 proficiency testing samples. RESULTS: Linear regression analysis of the quantitative results by the in-house assay showed the dynamic range from 2.60 to 9 log10 (plasma) and 2.94 to 9 log10 (viral transport medium) copies/mL, with the coefficient of determination (R2) of 0.996 and 0.998, respectively. A dilution series demonstrated the limits of detection and lower limits of quantification for plasma were 2.06 log10 and 2.60 log10 copies/mL and those for viral transport medium were 2.31 log10 and 2.94 log10 copies/mL respectively. The precision of the in-house assay was highly reproducible among runs with coefficients of variance ranging from 0.07 to 3.21% for plasma and 0.17% to 2.11% for viral transport medium. A comparison of 52 matched samples showed an excellent correlation between the quantitative viral loads measured by the in-house assay and the RealStar® Adenovirus PCR Kit (R2 = 0.984), with an average bias of - 0.16 log10 copies/mL. CONCLUSIONS: The in-house adenovirus assay is a sensitive and reliable assay with lower cost for the detection and quantification of adenoviral DNA when compared to the RealStar® Adenovirus PCR Kit.


Assuntos
Infecções por Adenoviridae/virologia , Adenovírus Humanos/isolamento & purificação , Técnicas de Diagnóstico Molecular/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Carga Viral/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
J Virol Methods ; 246: 112-116, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28476346

RESUMO

BACKGROUND: HHV-6 reactivation in immunocompromised patients is common and may be associated with serious morbidity and mortality; therefore, early detection and initiation of therapy might be of benefit. Real-time PCR assays allow for early identification of HHV-6 reactivation to assist in providing a timely response. Thus, we compared the performance of an in-house developed HHV-6 quantitative PCR assay with a commercially available kit, the RealStar® HHV-6 PCR Kit. METHOD: The analytical sensitivity, analytical specificity, linearity, precision and accuracy of the in-house developed HHV-6 qPCR assay were evaluated. The diagnostic performance of the in-house HHV-6 qPCR assay was compared with the RealStar® HHV-6 PCR Kit, using 72 clinical specimens and 17 proficiency testing samples. RESULTS: Linear regression analysis of the quantitative results showed a dynamic range from 2 to 10 log10 copies/ml and a coefficient of determination (R2) of 0.999 for the in-house assay. A dilution series demonstrated a limit of detection and a limit of quantification of 1.7 log10 and 2 log10 copies/ml, respectively. The precision of the assay was highly reproducible among runs with coefficients of variance (CV) ranging from 0.27% to 4.37%. A comparison of 27 matched samples showed an excellent correlation between the quantitative viral loads measured by the in-house HHV-6 qPCR assay and the RealStar® HHV-6 PCR Kit (R2=0.926; P<0.0001), with an average bias of -0.24 log10 copies/ml. CONCLUSIONS: The in-house developed HHV-6 qPCR method is a sensitive and reliable assay with lower cost for the detection and quantification of HHV-6 DNA when compared to the RealStar® HHV-6 PCR Kit.


Assuntos
Herpesvirus Humano 6/genética , Herpesvirus Humano 6/isolamento & purificação , Técnicas de Diagnóstico Molecular/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Infecções por Roseolovirus/virologia , Biópsia , DNA Viral , Humanos , Fígado/patologia , Fígado/virologia , Kit de Reagentes para Diagnóstico , Infecções por Roseolovirus/diagnóstico , Sensibilidade e Especificidade , Carga Viral/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA