Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Eur Spine J ; 2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38733400

RESUMO

PURPOSE: To analyze the effect of endplate weakness prior to PLIF or TLIF cage implantation and compare it to the opposite intact endplate of the same vertebral body. In addition, the influence of bone quality on endplate resistance was investigated. METHODS: Twenty-two human lumbar vertebrae were tested in a ramp-to-failure test. One endplate of each vertebral body was tested intact and the other after weakening with a rasp (over an area of 200 mm2). Either a TLIF or PLIF cage was then placed and the compression load was applied across the cage until failure of the endplate. Failure was defined as the first local maximum of the force measurement. Bone quality was assessed by determining the Hounsfield units (HU) on CT images. RESULTS: With an intact endplate and a TLIF cage, the median force to failure was 1276.3N (693.1-1980.6N). Endplate weakening reduced axial endplate resistance to failure by 15% (0-23%). With an intact endplate and a PLIF cage, the median force to failure was 1057.2N (701.2-1735.5N). Endplate weakening reduced axial endplate resistance to failure by 36.6% (7-47.9%). Bone quality correlated linearly with the force at which endplate failure occurred. Intact and weakened endplates showed a strong positive correlation: intact-TLIF: r = 0.964, slope of the regression line (slope) = 11.8, p < 0.001; intact-PLIF: r = 0.909, slope = 11.2, p = 5.5E-05; weakened-TLIF: r = 0.973, slope = 12.5, p < 0.001; weakened-PLIF: r = 0.836, slope = 6, p = 0.003. CONCLUSION: Weakening of the endplate during cage bed preparation significantly reduces the resistance of the endplate to subsidence to failure: endplate load capacity is reduced by 15% with TLIF and 37% with PLIF. Bone quality correlates with the force at which endplate failure occurs.

2.
J Orthop Res ; 42(7): 1566-1576, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38376065

RESUMO

Early aseptic loosening is caused by deficient osteointegration of the femoral stem due to increased micromotions and represents a common mode of failure in uncemented total hip arthroplasty (THA). This study hypothesized that a higher femoral offset, a smaller stem size and obesity increase femoral micromotion, potentially resulting in early aseptic loosening. A finite element analysis was conducted based on computed tomography segmented model of four patients who received a THA with a triple-tapered straight stem (Size 1, 3, 6). The influence of femoral stem offset (short neck, standard, lateral), head length (S to XXL), femoral anteversion and obesity during daily activities of fast walking and stair climbing was analyzed. The micromotions for the femoral stem zones were compared to a threshold representing a value above which only partial osseointegration is expected. The minimum femoral offset configuration compared to the maximum offset configuration (short neck stem, S head vs. lateral stem, XXL head) leads to a relative mean micromotion increase of 24% for the upper stem zone. Increasing the body weight (body mass index 30-35 kg/m2) increases the micromotion by 20% for all stem zones. The obese population recorded threshold-exceeding micromotions for stem sizes 1 and 3 for all offset configurations during stair climbing. Higher femoral offset, a smaller stem size, and higher loading due to obesity lead to an increase in micromotion between the prosthesis and proximal femur and represent a risk configuration for impaired osseointegration of a triple-tapered straight stem, especially when these three factors are present simultaneously.


Assuntos
Artroplastia de Quadril , Análise de Elementos Finitos , Osseointegração , Humanos , Prótese de Quadril , Idoso , Feminino , Pessoa de Meia-Idade , Masculino , Falha de Prótese
3.
Spine J ; 24(4): 730-735, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37871659

RESUMO

BACKGROUD CONTEXT: Pedicle screws are commonly used for posterior fixation of the lumbar spine. Inaccuracy of screw placement can lead to disastrous complications. PURPOSE: As fluoroscopic assisted pedicle screw instrumentation is the most frequently used technique, the aim of this study was to assess the specificity, sensitivity and accuracy of intraoperative fluoroscopy to detect mediolateral screw malpositioning. We also analyzed whether the addition of an oblique view could improve these parameters. STUDY DESIGN: On 12 human cadavers, 138 pedicle screws were placed intentionally either with 0 to 2 mm (75 screws), with 2 to 4 mm (six medial and 12 lateral screws) and with >4 mm (22 medial and 23 lateral screws) breach of the pedicle from Th12 to L5. METHODS: Three experienced spine surgeons evaluated the screw positioning in fluoroscopic AP views and 4 weeks later in AP views and additional oblique views. The surgeons' interpretation was compared with the effective screw position on postoperative CT scans. RESULTS: Pedicle breaches greater than 2 mm were detected in 68% with AP views and in 67% with additional oblique views (p=.742). The specificity of AP views was 0.86 and 0.93 with additional oblique views (p=<.01). The accuracy was 0.78 with AP views and 0.81 with AP + oblique views (p=.114). There was a substantial inter-reader agreement (Fleiss's kappa: 0.632). CONCLUSIONS: Fluoroscopic screening of pedicle screw misplacement has a limited sensitivity. Adding an oblique view improves specificity but not sensitivity and accuracy in detecting screw malpositions. CLINICAL SIGNIFICANCE: When in doubt of a screw malpositioning, other modalities than a fluoroscopic assisted pedicle screw instrumentation such as intraoperative CT imaging or an intraoperative exploration of the screw trajectory must be evaluated.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Humanos , Parafusos Pediculares/efeitos adversos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Tomografia Computadorizada por Raios X/métodos , Fluoroscopia/métodos , Complicações Pós-Operatórias/etiologia , Fusão Vertebral/métodos
4.
Artigo em Inglês | MEDLINE | ID: mdl-37942817

RESUMO

STUDY DESIGN: Biomechanical cadaveric study. OBJECTIVE: The goal of this study was to analyze the effects of an endoscopic transpedicular approach with different drill diameters (6 and 8 mm) to compare them with the intact native side. In addition, the influence of bone quality on the resistance of the pedicle was investigated. SUMMARY OF BACKGROUND DATA: Clinical studies have repeatedly highlighted the benefits of endoscopic transpedicular decompression for down-migrated lumbar disc herniations. However, the biomechanical effects on pedicle stability have not been studied up to now. METHODS: Twenty-four vertebras originating from four fresh-frozen cadavers were tested under uniaxial compression load in a ramp-to-failure test: (1) the tunneled pedicle on one side, and (2) the native pedicle on the other side. Twelve lumbar vertebrae were assigned to a drill diameter of 6 mm and the other 12 to a diameter of 8 mm. RESULTS: The median ratio of sustained force for the operated side compared to the intact contralateral side is equal to 74% (63-88) for both drill diameters combined. An 8 mm transpedicular approach recorded an axial resistance of 77% (60-88) compared to the intact contralateral side ( P =0.002). A 6 mm approach resulted in an axial resistance of 72% (66-84) compared to the intact opposite side ( P =0.01). No significant difference between the two different drill diameters was recorded ( P =1). For all 3 subgroups (intact, 8 mm, 6 mm) the HU-values and the absolute resistance force showed significant correlations (intact: ρ=0.859; P <0.001; 8 mm: ρ=0.902; P <0.001; 6 mm: ρ=0.835; P <0.001). CONCLUSION: Transpedicular approach significantly reduces the axial resistance force of the pedicle, which may lead to pedicle fracture. Bone quality correlated positively with the absolute resistance force of the pedicle, whereas the influence of the drill hole diameter plays only a limited role.

5.
JBJS Case Connect ; 13(4)2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37917724

RESUMO

CASE: Three patients with low-grade spondylolisthesis were treated with vertebropexy, a new surgical technique that replaces rigid fusion with ligamentous stabilization. Clinical outcomes, functional radiographs, and magnetic resonance imaging were used to document the early clinical results of this biomechanically established and promising new surgical method. CONCLUSION: Vertebropexy may be a valuable alternative to rigid fusion in the treatment of low-grade degenerative spondylolisthesis.


Assuntos
Fusão Vertebral , Espondilolistese , Humanos , Espondilolistese/diagnóstico por imagem , Espondilolistese/cirurgia , Espondilolistese/etiologia , Fusão Vertebral/efeitos adversos , Vértebras Lombares/cirurgia , Radiografia , Descompressão Cirúrgica/métodos
6.
Spine J ; 2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37924848

RESUMO

BACKGROUND CONTEXT: Posterior and transforaminal lumbar interbody fusion (PLIF, TLIF) are well-established procedures for spinal fusion. However, little is known about load sharing between cage, dorsal construct, and biological tissue within the instrumented lumbar spine. PURPOSE: The aim of this study was to quantify the forces acting on cages under axial compression force with and without posterior instrumentation. STUDY DESIGN: Biomechanical cadaveric study. METHODS: Ten lumbar spinal segments were tested under uniaxial compression using load cell instrumented intervertebral cages. The force was increased in 100N increments to 1000N or a force greater than 500N on one load cell. Each specimen was tested after unilateral PLIF (uPLIF), bilateral PLIF (bPLIF) and TLIF each with/without posterior instrumentation. Dorsal instrumentation was performed with 55N of compression per side. RESULTS: Cage insertion resulted in median cage preloads of 16N, 29N and 35N for uPLIF, bPLIF, and TLIF. The addition of compressed dorsal instrumentation increased the median preload to 224N, 328N, and 317N, respectively. With posterior instrumentation, the percentage of the external load acting on the intervertebral cage was less than 25% at 100N (uPLIF: 14.2%; bPLIF: 16%; TLIF: 11%), less than 45% at 500N (uPLIF: 31.8%; bPLIF: 41.1%; TLIF: 37.9%) and less than 50% at 1000N (uPLIF: 40.3%; bPLIF: 49.7%; TLIF: 43.4%). Without posterior instrumentation, the percentage of external load on the cages was significantly higher with values above 50% at 100N (uPLIF: 55.6%; bPLIF: 75.5%; TLIF: 66.8%), 500N (uPLIF: 71.7%; bPLIF: 79.2%; TLIF: 65.4%), and 1000N external load (uPLIF: 73%; bPLIF: 80.5%; TLIF: 66.1%). For absolute loads, preloads and external loads must be added together. CONCLUSIONS: Without posterior instrumentation, the intervertebral cages absorb more than 50% of the axial load and the load distribution is largely independent of the loading amplitude. With posterior instrumentation, the external load acting on the cages is significantly lower and the load distribution becomes load amplitude dependent, with a higher proportion of the load transferred by the cages at high loads. The bPLIF cages tend to absorb more force than the other two cage configurations. CLINICAL SIGNIFICANCE: Cage instrumentation allows some of the compression force to be transmitted through the cage to the screws below, better distributing and reducing the overall force on the pedicle screws at the end of the construct and on the rods.

7.
Front Bioeng Biotechnol ; 11: 1270522, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37954015

RESUMO

Background: Spinal fusion is the most common surgical treatment for the management of degenerative spinal disease. However, complications such as screw loosening lead to painful pseudoarthrosis, and are a common reason for revision. Optimization of screw trajectories to increase implant resistance to mechanical loading is essential. A recent optimization method has shown potential for determining optimal screw position and size based on areas of high bone elastic modulus (E-modulus). Aim: The aim of this biomechanical study was to verify the optimization algorithm for pedicle screw placement in a cadaveric study and to quantify the effect of optimization. The pull-out strength of pedicle screws with an optimized trajectory was compared to that of a traditional trajectory. Methods: Twenty-five lumbar vertebrae were instrumented with pedicle screws (on one side, the pedicle screws were inserted in the traditional way, on the other side, the screws were inserted using an optimized trajectory). Results: An improvement in pull-out strength and pull-out strain energy of the optimized screw trajectory compared to the traditional screw trajectory was only observed for E-modulus values greater than 3500 MPa cm3. For values of 3500 MPa cm3 or less, optimization showed no clear benefit. The median screw length of the optimized pedicle screws was significantly smaller than the median screw length of the traditionally inserted pedicle screws, p < 0.001. Discussion: Optimization of the pedicle screw trajectory is feasible, but seems to apply only to vertebrae with very high E-modulus values. This is likely because screw trajectory optimization resulted in a reduction in screw length and therefore a reduction in the implant-bone interface. Future efforts to predict the optimal pedicle screw trajectory should include screw length as a critical component of potential stability.

8.
Spine J ; 23(11): 1730-1737, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37451550

RESUMO

BACKGROUND CONTEXT: Posterior decompression with spinal instrumentation and fusion is associated with well-known complications. Alternatives that include decompression and restoration of native stability of the motion segment without fusion continue to be explored, however, an ideal solution has yet to be identified. PURPOSE: The aim of this study was to test two different synthetic lumbar vertebral stabilization techniques that can be used after unilateral total facetectomy. STUDY DESIGN: Biomechanical cadaveric study. METHODS: Twelve spinal segments were biomechanically tested after unilateral total facetectomy and stabilized with a FiberTape cerclage. The cerclage was pulled through the superior and inferior spinous process (interspinous technique) or through the spinous process and around both laminae (spinolaminar technique). The specimens were tested after (1) unilateral total facetectomy, (2) interspinous vertebropexy and (3) spinolaminar vertebropexy. The segments were loaded in flexion-extension (FE), lateral shear (LS), lateral bending (LB), anterior shear (AS) and axial rotation (AR). RESULTS: Unilateral facetectomy increased native ROM in FE by 10.6% (7.6%-12.6%), in LS by 25.8% (18.7%-28.4%), in LB 7.5% (4.6%-12.7%), in AS 39.4% (22.6%-49.2%), and in AR by 27.2% (15.8%-38.6%). Interspinous vertebropexy significantly reduced ROM after unilateral facetectomy: in FE by 73% (p=.001), in LS by 23% (p=.001), in LB by 13% (p=.003), in AS by 16% (p=.007), and in AR by 20% (p=.001). In FE and LS the ROM was lower than in the baseline/native condition. In AS and AR, the baseline ROM was not reached by 17% and 1%, respectively. Spinolaminar vertebropexy significantly reduced ROM after unilateral facetectomy: in FE by 74% (p=.001), in LS by 24% (p=.001), in LB by 13% (p=.003), in AS by 28% (p=.004), and in AR by 15 % (p=.001). Baseline ROM was not reached by 9% in AR. CONCLUSION: Interspinous vertebropexy seems to sufficiently counteract destabilization after unilateral total facetectomy, and limits range of motion in flexion and extension while avoiding full segmental immobilization. Spinolaminar vertebropexy additionally restores native anteroposterior stability, allowing satisfactory control of shear forces after facetectomy. CLINICAL SIGNIFICANCE: Lumbar vertebropexy seems promising to counteract the destabilizating effect of facetectomy by targeted stabilization.

9.
Eur Spine J ; 32(9): 3183-3191, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37284900

RESUMO

PURPOSE: To develop and test synthetic vertebral stabilization techniques ("vertebropexy") that can be used after decompression surgery and furthermore to compare them with a standard dorsal fusion procedure. METHODS: Twelve spinal segments (Th12/L1: 4, L2/3: 4, L4/5: 4) were tested in a stepwise surgical decompression and stabilization study. Stabilization was achieved with a FiberTape cerclage, which was pulled through the spinous process (interspinous technique) or through one spinous process and around both laminae (spinolaminar technique). The specimens were tested (1) in the native state, after (2) unilateral laminotomy, (3) interspinous vertebropexy and (4) spinolaminar vertebropexy. The segments were loaded in flexion-extension (FE), lateral shear (LS), lateral bending (LB), anterior shear (AS) and axial rotation (AR). RESULTS: Interspinous fixation significantly reduced ROM in FE by 66% (p = 0.003), in LB by 7% (p = 0.006) and in AR by 9% (p = 0.02). Shear movements (LS and AS) were also reduced, although not significantly: in LS reduction by 24% (p = 0.07), in AS reduction by 3% (p = 0.21). Spinolaminar fixation significantly reduced ROM in FE by 68% (p = 0.003), in LS by 28% (p = 0.01), in LB by 10% (p = 0.003) and AR by 8% (p = 0.003). AS was also reduced, although not significantly: reduction by 18% (p = 0.06). Overall, the techniques were largely comparable. The spinolaminar technique differed from interspinous fixation only in that it had a greater effect on shear motion. CONCLUSION: Synthetic vertebropexy is able to reduce lumbar segmental motion, especially in flexion-extension. The spinolaminar technique affects shear forces to a greater extent than the interspinous technique.


Assuntos
Vértebras Lombares , Fusão Vertebral , Humanos , Amplitude de Movimento Articular , Fenômenos Biomecânicos , Vértebras Lombares/cirurgia , Laminectomia , Fusão Vertebral/métodos , Cadáver
10.
Eur Spine J ; 32(6): 1876-1886, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37093262

RESUMO

PURPOSE: The aim of this study was to elucidate segmental range of motion (ROM) before and after common decompression and fusion procedures on the lumbar spine. METHODS: ROM of fourteen fresh-frozen human cadaver lumbar segments (L1/2: 4, L3/4: 5, L5/S1: 5) was evaluated in six loading directions: flexion/extension (FE), lateral bending (LB), lateral shear (LS), anterior shear (AS), axial rotation (AR), and axial compression/distraction (AC). ROM was tested with and without posterior instrumentation under the following conditions: 1) native 2) after unilateral laminotomy, 3) after midline decompression, and 4) after nucleotomy. RESULTS: Median native ROM was FE 6.8°, LB 5.6°, and AR 1.7°, AS 1.8 mm, LS 1.4 mm, AC 0.3 mm. Unilateral laminotomy significantly increased ROM by 6% (FE), 3% (LB), 12% (AR), 11% (AS), and 8% (LS). Midline decompression significantly increased these numbers to 15%, 5%, 21%, 20%, and 19%, respectively. Nucleotomy further increased ROM in all directions, most substantially in AC of 153%. Pedicle screw fixation led to ROM decreases of 82% in FE, 72% in LB, 42% in AR, 31% in AS, and 17% in LS. In instrumented segments, decompression only irrelevantly affected ROM. CONCLUSIONS: The amount of posterior decompression significantly impacts ROM of the lumbar spine. The here performed biomechanical study allows creation of a simplified rule of thumb: Increases in segmental ROM of approximately 10%, 20%, and 50% can be expected after unilateral laminotomy, midline decompression, and nucleotomy, respectively. Instrumentation decreases ROM by approximately 80% in bending moments and accompanied decompression procedures only minorly destabilize the instrumentation construct.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Humanos , Laminectomia , Fenômenos Biomecânicos , Fusão Vertebral/métodos , Vértebras Lombares/cirurgia , Amplitude de Movimento Articular , Cadáver , Descompressão
11.
Eur Spine J ; 32(4): 1401-1410, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36877366

RESUMO

PURPOSE: To compare the residual range of motion (ROM) of cortical screw (CS) versus pedicle screw (PS) instrumented lumbar segments and the additional effect of transforaminal interbody fusion (TLIF) and cross-link (CL) augmentation. METHODS: ROM of thirty-five human cadaver lumbar segments in flexion/extension (FE), lateral bending (LB), lateral shear (LS), anterior shear (AS), axial rotation (AR), and axial compression (AC) was recorded. After instrumenting the segments with PS (n = 17) and CS (n = 18), ROM in relation to the uninstrumented segments was evaluated without and with CL augmentation before and after decompression and TLIF. RESULTS: CS and PS instrumentations both significantly reduced ROM in all loading directions, except AC. In undecompressed segments, a significantly lower relative (and absolute) reduction of motion in LB was found with CS 61% (absolute 3.3°) as compared to PS 71% (4.0°; p = 0.048). FE, AR, AS, LS, and AC values were similar between CS and PS instrumented segments without interbody fusion. After decompression and TLIF insertion, no difference between CS and PS was found in LB and neither in any other loading direction. CL augmentation did not diminish differences in LB between CS and PS in the undecompressed state but led to an additional small AR reduction of 11% (0.15°) in CS and 7% (0.05°) in PS instrumentation. CONCLUSION: Similar residual motion is found with CS and PS instrumentation, except of slightly, but significantly inferior reduction of ROM in LB with CS. Differences between CS and PS in diminish with TLIF but not with CL augmentation.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Humanos , Vértebras Lombares/cirurgia , Fenômenos Biomecânicos , Amplitude de Movimento Articular , Cadáver , Descompressão
12.
Eur Spine J ; 32(5): 1695-1703, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36930387

RESUMO

PURPOSE: To develop ligamentous vertebral stabilization techniques ("vertebropexy") that can be used after microsurgical decompression (intact posterior structures) and midline decompression (removed posterior structures) and to elaborate their biomechanical characteristics. METHODS: Fifteen spinal segments were biomechanically tested in a stepwise surgical decompression and ligamentous stabilization study. Stabilization was achieved with a gracilis or semitendinosus tendon allograft, which was attached to the spinous process (interspinous vertebropexy) or the laminae (interlaminar vertebropexy) in form of a loop. The specimens were tested (1) in the native state, after (2) microsurgical decompression, (3) interspinous vertebropexy, (4) midline decompression, and (5) interlaminar vertebropexy. In the intact state and after every surgical step, the segments were loaded in flexion-extension (FE), lateral shear (LS), lateral bending (LB), anterior shear (AS) and axial rotation (AR). RESULTS: Interspinous vertebropexy significantly reduced the range of motion (ROM) in all loading scenarios compared to microsurgical decompression: in FE by 70% (p < 0.001), in LS by 22% (p < 0.001), in LB by 8% (p < 0.001) in AS by 12% (p < 0.01) and in AR by 9% (p < 0.001). Interlaminar vertebropexy decreased ROM compared to midline decompression by 70% (p < 0.001) in FE, 18% (p < 0.001) in LS, 11% (p < 0.01) in LB, 7% (p < 0.01) in AS, and 4% (p < 0.01) in AR. Vertebral segment ROM was significantly smaller with the interspinous vertebropexy compared to the interlaminar vertebropexy for all loading scenarios except FE. Both techniques were able to reduce vertebral body segment ROM in FE, LS and LB beyond the native state. CONCLUSION: Vertebropexy is a new concept of semi-rigid spinal stabilization based on ligamentous reinforcement of the spinal segment. It is able to reduce motion, especially in flexion-extension. Studies are needed to evaluate its clinical application.


Assuntos
Fusão Vertebral , Humanos , Fusão Vertebral/métodos , Vértebras Lombares/cirurgia , Fenômenos Biomecânicos , Descompressão Cirúrgica/métodos , Rotação , Amplitude de Movimento Articular , Cadáver
13.
Spine J ; 23(7): 1088-1095, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36805375

RESUMO

BACKGROUND CONTEXT: Transforaminal endoscopic decompression is an emerging minimally invasive surgical technique in spine surgery. The biomechanical effects and limitations of resections associated with this technique are scarce. PURPOSE: The objective of this study was to analyze the effects of three different extents of reduction at the craniomedial pedicle (10%, 25%, and 50%) and to compare them with the intact native side. In addition, the influence of bone quality on the resistance of the pedicle after reduction was investigated. STUDY DESIGN: Biomechanical cadaveric study. METHODS: Thirty lumbar vertebrae originating from six fresh frozen cadavers were tested under uniaxial compression load in a ramp-to-failure test: (1) the reduced pedicle on one side, and (2) the native pedicle on the other side. Of the 30 lumbar vertebrae, ten were assigned to each reduction group (10%, 25%, and 50%). RESULTS: On the intact side, the median axial compression force to failure was 593 N (442.4-785.8). A reduction of the pedicle by 10% of the cross-sectional area resulted in a decrease of the axial load resistance by 4% to 66% compared to the intact opposite side (p=.046). The median compression force to failure was 381.89 N (range: 336-662.1). A reduction by 25% resulted in a decrease of 7% to 71% (p=.001). The median compression force to failure was 333 N (265.1-397.3). A reduction by 50% resulted in a decrease of 39% to 90% (p<.001). The median compression force to failure was 200.9 N (192.3-283.9). At 10% pedicle reduction, the Hounsfield units (HU) value and the absolute force required to generate a pedicle fracture showed significant correlations (ρ=.872; p=.001). At 25%, a positive correlation between the two variables could still be identified (ρ=.603; p=.065). At 50%, no correlation was found (ρ=-.122; p=.738). CONCLUSION: Resection of the inner, upper part of the pedicle significantly reduces the axial resistance force of the pedicle until a fracture occurs. CLINICAL SIGNIFICANCE: The extent of pedicle reduction itself plays only a limited role: once the cortical bone in the pedicle region is compromised, significant loss of resistance to loading must be anticipated.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Humanos , Vértebras Lombares/cirurgia , Parafusos Ósseos , Descompressão Cirúrgica , Fusão Vertebral/métodos , Fenômenos Biomecânicos , Cadáver
14.
Eur Spine J ; 32(4): 1411-1420, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36820922

RESUMO

PURPOSE: To elucidate residual motion of cortical screw (CS) and pedicle screw (PS) constructs with unilateral posterior lumbar interbody fusion (ul-PLIF), bilateral PLIF (bl-PLIF), facet-sparing transforaminal lumbar interbody fusion (fs-TLIF), and facet-resecting TLIF (fr-TLIF). METHODS: A total of 35 human cadaver lumbar segments were instrumented with PS (n = 18) and CS (n = 17). Range of motion (ROM) and relative ROM changes were recorded in flexion/extension (FE), lateral bending (LB), axial rotation (AR), lateral shear (LS), anterior shear (AS), and axial compression (AC) in five instrumentational states: without interbody fusion (wo-IF), ul-PLIF, bl-PLIF, fs-TLIF, and fr-TLIF. RESULTS: Whereas FE, LB, AR, and AC noticeably differed between the instrumentational states, AS and LS were less prominently affected. Compared to wo-IF, ul-PLIF caused a significant increase in ROM with PS (FE + 42%, LB + 24%, AR + 34%, and AC + 77%), however, such changes were non-significant with CS. ROM was similar between wo-IF and all other interbody fusion techniques. Insertion of a second PLIF (bl-PLIF) significantly decreased ROM with CS (FE -17%, LB -26%, AR -20%, AC -51%) and PS (FE - 23%, LB - 14%, AR - 20%, AC - 45%,). Facet removal in TLIF significantly increased ROM with CS (FE + 6%, LB + 9%, AR + 17%, AC of + 23%) and PS (FE + 7%, AR + 12%, AC + 13%). CONCLUSION: bl-PLIF and TLIF show similarly low residual motion in both PS and CS constructs, but ul-PLIF results in increased motion. The fs-TLIF technique is able to further decrease motion compared to fr-TLIF in both the CS and PS constructs.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Humanos , Vértebras Lombares/cirurgia , Fusão Vertebral/métodos , Fenômenos Biomecânicos , Fixadores Internos , Amplitude de Movimento Articular
15.
Front Bioeng Biotechnol ; 10: 1034441, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36582835

RESUMO

Intervertebral discs are microstructurally complex spinal tissues that add greatly to the flexibility and mechanical strength of the human spine. Attempting to provide an adjustable basis for capturing a wide range of mechanical characteristics and to better address known challenges of numerical modeling of the disc, we present a robust finite-element-based model formulation for spinal segments in a hyperelastic framework using tetrahedral elements. We evaluate the model stability and accuracy using numerical simulations, with particular attention to the degenerated intervertebral discs and their likely skewed and narrowed geometry. To this end, 1) annulus fibrosus is modeled as a fiber-reinforced Mooney-Rivlin type solid for numerical analysis. 2) An adaptive state-variable dependent explicit time step is proposed and utilized here as a computationally efficient alternative to theoretical estimates. 3) Tetrahedral-element-based FE models for spinal segments under various loading conditions are evaluated for their use in robust numerical simulations. For flexion, extension, lateral bending, and axial rotation load cases, numerical simulations reveal that a suitable framework based on tetrahedral elements can provide greater stability and flexibility concerning geometrical meshing over commonly employed hexahedral-element-based ones for representation and study of spinal segments in various stages of degeneration.

16.
Spine (Phila Pa 1976) ; 47(24): 1753-1760, 2022 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-36083835

RESUMO

STUDY DESIGN: Biomechanical cadaveric study. OBJECTIVE: The aim of this study was to compare the effect of transforaminal endoscopic approaches with open decompression procedures. SUMMARY OF BACKGROUND DATA: Clinical studies have repeatedly highlighted the benefits of endoscopic decompression, however, the biomechanical effects of endoscopic approaches (with and without injury to the disk) have not been studied up to now. MATERIALS AND METHODS: Twelve spinal segments originating from four fresh-frozen cadavers were biomechanically tested in a load-controlled endoscopic transforaminal approach study. Segmental range of motion (ROM) after endoscopic approach was compared with segmental ROM after (1) microsurgical decompression with unilateral laminotomy and (2) midline decompression with bilateral laminotomy. In the intact state and after decompression, the segments were loaded in flexion-extension (FE), lateral shear (LS), lateral bending (LB), anterior shear (AS), and axial rotation (AR). RESULTS: Vertebral segment ROM was comparable between the two endoscopic transforaminal approaches. However, there was a-statistically nonsignificant-trend for a larger ROM after accessing via the inside-out technique: FE: +3% versus +7%, P =0.484; LS: +1% versus +12%, P =0.18; LB: +0.6% versus +9%, P =0.18; AS: +2% versus +11%, P =0.31; AR: -4% versus +5%, P =0.18. No significant difference in vertebral segment ROM was seen between the transforaminal endoscopic approaches and open unilateral decompression. Vertebral segment ROM was significantly smaller with the transforaminal endoscopic approaches compared with midline decompression for almost all loading scenarios: FE: +4% versus +17%, P =0.005; AS: +6% versus 21%, P =0.007; AR: 0% versus +24%, P =0.002. CONCLUSION: The transforaminal endoscopic intracanal technique preserves the native ROM of lumbar vertebral segments and shows a trend toward relative biomechanical superiority over the inside-out technique and open decompression procedures.


Assuntos
Vértebras Lombares , Fusão Vertebral , Humanos , Fenômenos Biomecânicos , Vértebras Lombares/cirurgia , Fusão Vertebral/métodos , Descompressão Cirúrgica/métodos , Amplitude de Movimento Articular , Cadáver
17.
Sci Rep ; 12(1): 7621, 2022 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-35538122

RESUMO

Posterior screw-rod constructs can be used to stabilize spinal segments; however, the stiffness is not absolute, and some motion can persist. While the effect of crosslink-augmentation has been evaluated in multiple studies, the fundamental explanation of their effectiveness has not been investigated. The aim of this study was to quantify the parameters "screw rotation" and "parallelogram deformation" in posterior instrumentations with and without crosslinks to analyze and explain their fundamental effect. Biomechanical testing of 15 posteriorly instrumented human spinal segments (Th10/11-L4/L5) was conducted in axial rotation, lateral bending, and flexion-extension with ± 7.5 Nm. Screw rotation and parallelogram deformation were compared for both configurations. Parallelogram deformation occurred predominantly during axial rotation (2.6°) and was reduced by 60% (-1.45°, p = 0.02) by the addition of a crosslink. Simultaneously, screw rotation (0.56°) was reduced by 48% (-0.27°, p = 0.02) in this loading condition. During lateral bending, 0.38° of parallelogram deformation and 1.44° of screw rotation was measured and no significant reduction was achieved by crosslink-augmentation (8%, -0.03°, -p = 0.3 and -13%, -0.19°, p = 0.7 respectively). During flexion-extension, parallelogram deformation was 0.4° and screw rotation was 0.39° and crosslink-augmentation had no significant effect on these values (-0.12°, -30%, p = 0.5 and -0°, -0%, p = 0.8 respectively). In axial rotation, crosslink-augmentation can reduce parallelogram deformation and with that, screw rotation. In lateral bending and flexion-extension parallelogram deformation is minimal and crosslink-augmentation has no significant effect. Since the relatively large screw rotation in lateral bending is not caused by parallelogram deformation, crosslink-augmentation is no adequate countermeasure. The fundamental understanding of the biomechanical effect of crosslink-augmentation helps better understand its potential and limitations in increasing construct stiffness.


Assuntos
Parafusos Ósseos , Fusão Vertebral , Fenômenos Biomecânicos , Cadáver , Fixação Interna de Fraturas , Humanos , Vértebras Lombares/cirurgia , Procedimentos Neurocirúrgicos , Amplitude de Movimento Articular , Rotação
18.
Eur Spine J ; 31(10): 2639-2649, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35461383

RESUMO

PURPOSE: Pedicle screw loosening is a frequent complication in lumbar spine fixation, most commonly among patients with poor bone quality. Determining patients at high risk for insufficient implant stability would allow clinicians to adapt the treatment accordingly. The aim of this study was to develop a computational model for quantitative and reliable assessment of the risk of screw loosening. METHODS: A cohort of patient vertebrae with diagnosed screw loosening was juxtaposed to a control group with stable fusion. Imaging data from the two cohorts were used to generate patient-specific biomechanical models of lumbar instrumented vertebral bodies. Single-level finite element models loading the screw in axial or caudo-cranial direction were generated. Further, multi-level models incorporating individualized joint loading were created. RESULTS: The simulation results indicate that there is no association between screw pull-out strength and the manifestation of implant loosening (p = 0.8). For patient models incorporating multiple instrumented vertebrae, CT-values and stress in the bone were significantly different between loose screws and non-loose screws (p = 0.017 and p = 0.029, for CT-values and stress, respectively). However, very high distinction (p = 0.001) and predictability (R2Pseudo = 0.358, AUC = 0.85) were achieved when considering the relationship between local bone strength and the predicted stress (loading factor). Screws surrounded by bone with a loading factor higher than 25% were likely to be loose, while the chances of screw loosening were close to 0 with a loading factor below 15%. CONCLUSION: The use of a biomechanics-based score for risk assessment of implant fixation failure might represent a paradigm shift in addressing screw loosening after spondylodesis surgery.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Fenômenos Biomecânicos , Simulação por Computador , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Parafusos Pediculares/efeitos adversos , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos
19.
Comput Methods Biomech Biomed Engin ; 25(4): 464-474, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34369827

RESUMO

Pedicle screw instrumentation is performed in the surgical treatment of a wide variety of spinal pathologies. A common postoperative complication associated with this procedure is screw loosening. It has been shown that patient-specific screw fixation can be automated to match standard clinical practice and that failure can be estimated preoperatively using computed tomography images. Hence, we set out to optimize three-dimensional preoperative planning to achieve more mechanically robust screw purchase allowing deviation from intuitive, standard screw parameters. Toward this purpose, we employed a genetic algorithm optimization to find optimal screw sizes and trajectories by maximizing the CT derived bone mechanical properties. The method was tested on cadaveric lumbar vertebrae (L1 to L5) of four human spines (2 female/2 male; age range 60-78 years). The main boundary conditions were the predefined, level-dependent areas of possible screw entry points, as well as the automatically located pedicle structures. Finite element analysis was used to compare the genetic algorithm output to standard clinical planning of screw positioning in terms of the simulated pull-out strength. The genetic algorithm optimization successfully found screw sizes and trajectories that maximize the sum of the Young's modulus within the screw's volume for all 40 pedicle screws included in this study. Overall, there was a 26% increase in simulated pull-out strength for optimized compared to traditional screw trajectories and sizes. Our results indicate that optimizing pedicle screw instrumentation in lumbar vertebrae based on bone quality measures improves screw purchase as compared to traditional instrumentation.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Idoso , Fenômenos Biomecânicos , Densidade Óssea , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Fusão Vertebral/métodos , Tomografia Computadorizada por Raios X
20.
Front Bioeng Biotechnol ; 9: 721042, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34532314

RESUMO

Musculoskeletal modeling is a well-established method in spine biomechanics and generally employed for investigations concerning both the healthy and the pathological spine. It commonly involves inverse kinematics and optimization of muscle activity and provides detailed insight into joint loading. The aim of the present work was to develop and validate a procedure for the automatized generation of semi-subject-specific multi-rigid body models with an articulated lumbar spine. Individualization of the models was achieved with a novel approach incorporating information from annotated EOS images. The size and alignment of bony structures, as well as specific body weight distribution along the spine segments, were accurately reproduced in the 3D models. To ensure the pipeline's robustness, models based on 145 EOS images of subjects with various weight distributions and spinopelvic parameters were generated. For validation, we performed kinematics-dependent and segment-dependent comparisons of the average joint loads obtained for our cohort with the outcome of various published in vivo and in situ studies. Overall, our results agreed well with literature data. The here described method is a promising tool for studying a variety of clinical questions, ranging from the evaluation of the effects of alignment variation on joint loading to the assessment of possible pathomechanisms involved in adjacent segment disease.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA