Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
J Biomech ; 169: 112133, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38744146

RESUMO

Abnormal loading is thought to play a key role in the disease progression of cartilage, but our understanding of how cartilage compositional measurements respond to acute compressive loading in-vivo is limited. Ten healthy subjects were scanned at two timepoints (7 ± 3 days apart) with a 3 T magnetic resonance imaging (MRI) scanner. Scanning sessions included T1ρ and T2* acquisitions of each knee in two conditions: unloaded (traditional MRI setup) and loaded in compression at 40 % bodyweight as applied by an MRI-compatible loading device. T1ρ and T2* parameters were quantified for contacting cartilage (tibial and femoral) and non-contacting cartilage (posterior femoral condyle) regions. Significant effects of load were found in contacting regions for both T1ρ and T2*. The effect of load (loaded minus unloaded) in femoral contacting regions ranged from 4.1 to 6.9 ms for T1ρ, and 3.5 to 13.7 ms for T2*, whereas tibial contacting regions ranged from -5.6 to -1.7 ms for T1ρ, and -2.1 to 0.7 ms for T2*. Notably, the responses to load in the femoral and tibial cartilage revealed opposite effects. No significant differences were found in response to load between the two visits. This is the first study that analyzed the effects of acute loading on T1ρ and T2* measurements in human femoral and tibial cartilage separately. The results suggest the effect of acute compressive loading on T1ρ and T2* was: 1) opposite in the femoral and tibial cartilage; 2) larger in contacting regions than in non-contacting regions of the femoral cartilage; and 3) not different visit-to-visit.


Assuntos
Cartilagem Articular , Fêmur , Imageamento por Ressonância Magnética , Tíbia , Suporte de Carga , Humanos , Cartilagem Articular/fisiologia , Cartilagem Articular/diagnóstico por imagem , Fêmur/diagnóstico por imagem , Fêmur/fisiologia , Masculino , Adulto , Feminino , Imageamento por Ressonância Magnética/métodos , Tíbia/diagnóstico por imagem , Tíbia/fisiologia , Suporte de Carga/fisiologia , Articulação do Joelho/fisiologia , Articulação do Joelho/diagnóstico por imagem , Força Compressiva/fisiologia
2.
Med Sci Sports Exerc ; 55(10): 1913-1922, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37259254

RESUMO

INTRODUCTION: Athletes use their skeletal muscles to demonstrate performance. Muscle force generating capacity is correlated with volume, meaning that variations in sizes of different muscles may be indicative of how athletes meet different demands in their sports. Medical imaging enables in vivo quantification of muscle volumes; however, muscle volume distribution has not been compared across athletes of different sports. PURPOSE: The goal of this work was to define "muscular phenotypes" in athletes of different sports and compare these using hierarchical clustering. METHODS: Muscle volumes normalized by body mass of athletes (football, baseball, basketball, or track) were compared with control participants to quantify size differences using z -scores. z -Scores of 35 muscles described the pattern of volume deviation within each athlete's lower limb, characterizing their muscular phenotype. Data-driven high-dimensional clustering analysis was used to group athletes presenting similar phenotypes. Efficacy of clustering to identify similar phenotypes was demonstrated by grouping athletes' contralateral limbs before other athletes' limbs. RESULTS: Analyses revealed that athletes did not tend to cluster with others competing in the same sport. Basketball players with similar phenotypes grouped by clustering also demonstrated similarities in performance. Clustering also identified muscles with similar volume variation patterns across athletes, and principal component analysis revealed specific muscles that accounted for most of the variance (gluteus maximus, sartorius, semitendinosus, vastus medialis, vastus lateralis, and rectus femoris). CONCLUSIONS: Athletes exhibit heterogeneous lower limb muscle volumes that can be characterized and compared as individual muscular phenotypes. Clustering revealed that athletes with the most similar phenotypes do not always play the same sport such that patterns of muscular heterogeneity across a group of athletes reflect factors beyond their specific sports.


Assuntos
Basquetebol , Extremidade Inferior , Humanos , Extremidade Inferior/fisiologia , Músculo Quadríceps/fisiologia , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Atletas , Basquetebol/fisiologia
3.
Med Eng Phys ; 114: 103968, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-37030894

RESUMO

Model-based tracking (MBT) is a time-consuming and semiautomatic approach, and thus subject to errors during the tracking process. The present study aimed primarily to quantify the effects that interpolation and intra-user variability associated with MBT have on the kinematic and arthrokinematic measurements in comparison to a gold standard radiostereometric analysis (RSA). Cadaveric knee specimens were imaged at 125 Hz while simulating standing, walking, jogging, and lunging motions. (Arthro)kinematic metrics were calculated via MBT without interpolation, MBT with two interpolation techniques when every fifth or tenth frame was analyzed, and RSA. Tracking the same activity multiple times affected (p-value, largest mean difference) the flexion-extension (FE) joint angle during walking (0.03, 0.6°), and the internal-external joint angle during jogging (0.048, -0.9°). Only during jogging for the FE joint angle was there an effect of interpolation (0.046, 0.3°). Neither tracking multiple times nor interpolation affected arthrokinematic metrics (contact path locations and excursions). The present study is the first to quantify the effects that intra-user variability and interpolation have on the (arthro)kinematic measurement accuracy using MBT. Results suggest interpolation may be used without sacrificing (arthro)kinematic outcome measurement accuracy and the errors associated with intra-user variability, while small, were larger than errors due to interpolation.


Assuntos
Articulação do Joelho , Joelho , Humanos , Articulação do Joelho/diagnóstico por imagem , Joelho/diagnóstico por imagem , Caminhada , Fenômenos Biomecânicos , Fluoroscopia/métodos , Amplitude de Movimento Articular
4.
J Biomech ; 146: 111424, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36603366

RESUMO

Femoroacetabular impingement syndrome (FAIS) is a motion-related pathology of the hip characterized by pain, morphological abnormalities of the proximal femur, and an elevated risk of joint deterioration and hip osteoarthritis. Activities that require deep flexion are understood to induce impingement in cam FAIS patients, however, less demanding activities such as walking and pivoting may induce pain as well as alterations in kinematics and joint stability. Still, the paucity of quantitative descriptions of cam FAIS has hindered understanding underlying hip joint mechanics during such activities. Previous in silico studies have employed generalized model geometry or kinematics to simulate impingement between the femur and acetabulum, which may not accurately capture the interplay between morphology and motion. In this study, we utilized models with participant-specific bone and articular soft tissue anatomy and kinematics measured by dual-fluoroscopy to compare hip contact mechanics of cam FAIS patients to controls during four activities of daily living (internal/external pivoting and level/incline walking). Averaged across the gait cycle during incline walking, patients displayed increased strain in the anterior joint (labrum strain: p-value = 0.038, patients: 11.7 ± 6.7 %, controls: 5.0 ± 3.6 %; cartilage strain: p-value = 0.029, patients: 9.1 ± 3.3 %, controls: 4.2 ± 2.3). Patients also exhibited increased average anterior cartilage strains during external pivoting (p-value = 0.039; patients: 13.0 ± 9.2 %, controls: 3.9 ± 3.2 %]). No significant differences between patient and control contact area and strain were found for level walking and internal pivoting. Our study provides new insights into the biomechanics of cam FAIS, including spatiotemporal hip joint contact mechanics during activities of daily living.


Assuntos
Impacto Femoroacetabular , Humanos , Atividades Cotidianas , Articulação do Quadril , Acetábulo , Caminhada , Cartilagem , Dor
5.
J Orthop Res ; 41(1): 161-169, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35325481

RESUMO

Cam-type femoroacetabular impingement (FAI) syndrome is a painful, structural hip disorder. Herein, we investigated hip joint mechanics through in vivo, dynamic measurement of the bone-to-bone distance between the femoral head and acetabulum in patients with cam FAI syndrome and morphologically screened controls. We hypothesized that individuals with cam FAI syndrome would have larger changes in bone-to-bone distance compared to the control group, which we would interpret as altered joint mechanics as signified by greater movement of the femoral head as it articulates within the acetabulum. Seven patients with cam FAI syndrome and 11 asymptomatic individuals with typical morphology underwent dual fluoroscopy imaging during level and inclined walking (upward slope). The change in bone-to-bone distance between femoral and acetabular bone surfaces was evaluated for five anatomical regions of the acetabulum at each timepoint of gait. Linear regression analysis of the bone-to-bone distance considered two within-subject factors (activity and region) and one between-subjects factor (group). Across activities, the change in minimum bone-to-bone distance was 1.38-2.54 mm for the cam FAI group and 1.16-1.84 mm for controls. In all regions except the anterior-superior region, the change in bone-to-bone distance was larger in the cam group than the control group (p ≤ 0.024). An effect of activity was detected only in the posterior-superior region where larger changes were noted during level walking than incline walking. Statement of clinical significance: Patients with cam FAI syndrome exhibit altered hip joint mechanics during the low-demand activity of walking; these alterations could affect load transmission, and contribute to pain, tissue damage, and osteoarthritis.


Assuntos
Impacto Femoroacetabular , Caminhada , Humanos , Impacto Femoroacetabular/diagnóstico por imagem , Impacto Femoroacetabular/fisiopatologia , Marcha , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiopatologia
6.
IEEE Trans Biomed Eng ; 69(2): 580-589, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34351852

RESUMO

Complex sensor arrays prohibit practical deployment of existing wearables-based algorithms for free-living analysis of muscle and joint mechanics. Machine learning techniques have been proposed as a potential solution, however, they are less interpretable and generalizable when compared to physics-based techniques. Herein, we propose a hybrid method utilizing inertial sensor- and electromyography (EMG)-driven simulation of muscle contraction to characterize knee joint and muscle mechanics during walking gait. Machine learning is used only to map a subset of measured muscle excitations to a full set thereby reducing the number of required sensors. We demonstrate the utility of the approach for estimating net knee flexion moment (KFM) as well as individual muscle moment and work during the stance phase of gait across nine unimpaired subjects. Across all subjects, KFM was estimated with 0.91%BW•H RMSE and strong correlations (r = 0.87) compared to ground truth inverse dynamics analysis. Estimates of individual muscle moments were strongly correlated (r = 0.81-0.99) with a reference EMG-driven technique using optical motion capture and a full set of electrodes as were estimates of muscle work (r = 0.88-0.99). Implementation of the proposed technique in the current work included instrumenting only three muscles with surface electrodes (lateral and medial gastrocnemius and vastus medialis) and both the thigh and shank segments with inertial sensors. These sensor locations permit instrumentation of a knee brace/sleeve facilitating a practically deployable mechanism for monitoring muscle and joint mechanics with performance comparable to the current state-of-the-art.


Assuntos
Caminhada , Dispositivos Eletrônicos Vestíveis , Fenômenos Biomecânicos , Eletromiografia/métodos , Marcha/fisiologia , Humanos , Articulação do Joelho/fisiologia , Contração Muscular/fisiologia , Músculo Esquelético/fisiologia , Caminhada/fisiologia
7.
J Vis Exp ; (173)2021 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-34279514

RESUMO

Several hip pathologies have been attributed to abnormal morphology with an underlying assumption of aberrant biomechanics. However, structure-function relationships at the joint level remain challenging to quantify due to difficulties in accurately measuring dynamic joint motion. The soft tissue artifact errors inherent in optical skin marker motion capture are exacerbated by the depth of the hip joint within the body and the large mass of soft tissue surrounding the joint. Thus, the complex relationship between bone shape and hip joint kinematics is more difficult to study accurately than in other joints. Herein, a protocol incorporating computed tomography (CT) arthrography, three-dimensional (3D) reconstruction of volumetric images, dual fluoroscopy, and optical motion capture to accurately measure the dynamic motion of the hip joint is presented. The technical and clinical studies that have applied dual fluoroscopy to study form-function relationships of the hip using this protocol are summarized, and the specific steps and future considerations for data acquisition, processing, and analysis are described.


Assuntos
Articulação do Quadril , Imageamento Tridimensional , Fenômenos Biomecânicos , Fluoroscopia , Articulação do Quadril/diagnóstico por imagem , Amplitude de Movimento Articular , Suporte de Carga
8.
J Biomech ; 108: 109890, 2020 07 17.
Artigo em Inglês | MEDLINE | ID: mdl-32636003

RESUMO

Rigid body musculoskeletal models have been applied to study kinematics, moments, muscle forces, and joint reaction forces in the hip. Most often, models are driven with segment motions calculated through optical tracking of markers adhered to the skin. One limitation of optical tracking is soft tissue artifact (STA), which occurs due to motion of the skin surface relative to the underlying skeleton. The purpose of this study was to quantify differences in musculoskeletal model outputs when tracking body segment positions with skin markers as compared to bony landmarks measured by direct imaging of bone motion with dual fluoroscopy (DF). Eleven asymptomatic participants with normally developed hip anatomy were imaged with DF during level treadmill walking at a self-selected speed. Hip joint kinematics and kinetics were generated using inverse kinematics, inverse dynamics, static optimization and joint reaction force analysis. The effect of STA was assessed by comparing the difference in estimates from simulations based on skin marker positions (SM) versus virtual markers on bony landmarks from DF. While patterns were similar, STA caused underestimation of kinematics, range of motion (ROM), moments, and reaction forces at the hip, including flexion-extension ROM, maximum internal rotation joint moment and peak joint reaction force magnitude. Still, kinetic differences were relatively small, and thus they may not be relevant nor clinically meaningful.


Assuntos
Artefatos , Articulação do Quadril , Fenômenos Biomecânicos , Marcha , Humanos , Cinética , Amplitude de Movimento Articular
9.
J Orthop Res ; 38(4): 823-833, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31693209

RESUMO

Femoroacetabular impingement syndrome (FAIS) may alter the kinematic function of the hip, resulting in pain and tissue damage. Previous motion analysis studies of FAIS have employed skin markers, which are prone to soft tissue artifact and inaccurate calculation of the hip joint center. This may explain why the evidence linking FAIS with deleterious kinematics is contradictory. The purpose of this study was to employ dual fluoroscopy (DF) to quantify in vivo kinematics of patients with cam FAIS relative to asymptomatic, morphologically normal control participants during various activities. Eleven asymptomatic, morphologically normal controls and seven patients with cam FAIS were imaged with DF during standing, level walking, incline walking, and functional range of motion activities. Model-based tracking calculated the kinematic position of the hip by registering projections of three-dimensional computed tomography models with DF images. Patients with FAIS stood with their hip extended (mean [95% confidence interval], -2.2 [-7.4, 3.1]°, flexion positive), whereas controls were flexed (5.3 [2.6, 8.0]°; p = 0.013). Male patients with cam FAIS had less peak internal rotation than the male control participants during self-selected speed level-walking (-0.2 [-6.5, 6.1]° vs. -9.8 [-12.2, -7.3]°; p = 0.007) and less anterior pelvic tilt at heel-strike of incline (5°) walking (3.4 [-1.0, -7.9]° vs. 9.8 [6.4, 13.2]°; p = 0.032). Even during submaximal range of motion activities, such as incline walking, patients may alter pelvic motion to avoid positions that approximate the cam lesion and the acetabular labrum. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 38:823-833, 2020.


Assuntos
Impacto Femoroacetabular/fisiopatologia , Articulação do Quadril/fisiopatologia , Ossos Pélvicos/fisiopatologia , Adulto , Fenômenos Biomecânicos , Estudos de Casos e Controles , Feminino , Impacto Femoroacetabular/diagnóstico por imagem , Fluoroscopia , Marcha , Humanos , Masculino , Adulto Jovem
10.
Gait Posture ; 61: 276-281, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29413797

RESUMO

BACKGROUND: Individuals are thought to compensate for femoral anteversion by altering hip rotation. However, the relationship between hip rotation in a neutral position (i.e. static rotation) and dynamic hip rotation is poorly understood, as is the relationship between anteversion and hip rotation. RESEARCH OBJECTIVE: Herein, anteversion and in-vivo hip rotation during standing, walking, and pivoting were measured in eleven asymptomatic, morphologically normal, young adults using three-dimensional computed tomography models and dual fluoroscopy. METHODS: Using correlation analyses, we: 1) determined the relationship between hip rotation in the static position to that measured during dynamic activities, and 2) evaluated the association between femoral anteversion and hip rotation during dynamic activities. Hip rotation was calculated while standing (static-rotation), throughout gait, as a mean during gait (mean gait rotation), and as a mean (mid-pivot rotation), maximum (max-rotation) and minimum (min-rotation) during pivoting. RESULTS: Static-rotation (mean ±â€¯standard deviation; 11.3°â€¯±â€¯7.3°) and mean gait rotation (7.8°â€¯±â€¯4.7°) were positively correlated (r = 0.679, p = 0.022). Likewise, static-rotation was strongly correlated with mid-pivot rotation (r = 0.837, p = 0.001), max-rotation (r = 0.754, p = 0.007), and min-rotation (r = 0.835, p = 0.001). Strong positive correlations were found between anteversion and hip internal rotation during all of the stance phase (0-60% gait) and during mid- and terminal-swing (86-100% gait) (all r > 0.607, p < 0.05). CONCLUSIONS: Our results suggest that the static position may be used cautiously to express the neutral rotational position of the femur for dynamic movements. Further, our results indicate that femoral anteversion is compensated for by altering hip rotation. As such, both anteversion and hip rotation may be important to consider when diagnosing hip pathology and planning for surgical procedures.


Assuntos
Fêmur/diagnóstico por imagem , Marcha/fisiologia , Articulação do Quadril/diagnóstico por imagem , Rotação , Adulto , Artrografia , Feminino , Fêmur/fisiologia , Fluoroscopia , Articulação do Quadril/fisiologia , Humanos , Imageamento Tridimensional , Masculino , Tomografia Computadorizada por Raios X , Caminhada , Adulto Jovem
11.
Am J Sports Med ; 45(12): 2901-2910, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28682639

RESUMO

BACKGROUND: Ischiofemoral impingement (IFI) is a dynamic process, but its diagnosis is often based on static, supine images. PURPOSE: To couple 3-dimensional (3D) computed tomography (CT) models with dual fluoroscopy (DF) images to quantify in vivo hip motion and the ischiofemoral space (IFS) in asymptomatic participants during weightbearing activities and evaluate the relationship of dynamic measurements with sex, hip kinematics, and the IFS measured from axial magnetic resonance imaging (MRI). STUDY DESIGN: Cross-sectional study; Level of evidence, 3. METHODS: Eleven young, asymptomatic adults (5 female) were recruited. 3D reconstructions of the femur and pelvis were generated from MRI and CT. The axial and 3D IFS were measured from supine MRI. In vivo hip motion during weightbearing activities was quantified using DF. The bone-to-bone distance between the lesser trochanter and ischium was measured dynamically. The minimum and maximum IFS were determined and evaluated against hip joint angles using a linear mixed-effects model. RESULTS: The minimum IFS occurred during external rotation for 10 of 11 participants. The IFS measured from axial MRI (mean, 23.7 mm [95% CI, 19.9-27.9]) was significantly greater than the minimum IFS observed during external rotation (mean, 10.8 mm [95% CI, 8.3-13.7]; P < .001), level walking (mean, 15.5 mm [95% CI, 11.4-19.7]; P = .007), and incline walking (mean, 15.8 mm [95% CI, 11.6-20.1]; P = .004) but not for standing. The IFS was reduced with extension (ß = 0.66), adduction (ß = 0.22), and external rotation (ß = 0.21) ( P < .001 for all) during the dynamic activities observed. The IFS was smaller in female than male participants for standing (mean, 20.9 mm [95% CI, 19.3-22.3] vs 30.4 mm [95% CI, 27.2-33.8], respectively; P = .034), level walking (mean, 8.8 mm [95% CI, 7.5-9.9] vs 21.1 mm [95% CI, 18.7-23.6], respectively; P = .001), and incline walking (mean, 9.1 mm [95% CI, 7.4-10.8] vs 21.3 mm [95% CI, 18.8-24.1], respectively; P = .003). Joint angles between the sexes were not significantly different for any of the dynamic positions of interest. CONCLUSION: The minimum IFS during dynamic activities was smaller than axial MRI measurements. Compared with male participants, the IFS in female participants was reduced during standing and walking, despite a lack of kinematic differences between the sexes. The relationship between the IFS and hip joint angles suggests that the hip should be placed into greater extension, adduction, and external rotation in clinical examinations and imaging, as the IFS measured from static images, especially in a neutral orientation, may not accurately represent the minimum IFS during dynamic motion. Nevertheless, this statement must be interpreted with caution, as only asymptomatic participants were analyzed herein.


Assuntos
Impacto Femoroacetabular/diagnóstico por imagem , Impacto Femoroacetabular/patologia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/patologia , Adulto , Doenças Assintomáticas , Fenômenos Biomecânicos , Estudos Transversais , Feminino , Fêmur/diagnóstico por imagem , Fêmur/patologia , Fluoroscopia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pelve/diagnóstico por imagem , Pelve/patologia , Recreação/fisiologia , Rotação , Tomografia Computadorizada por Raios X , Caminhada/fisiologia , Adulto Jovem
12.
Ann Biomed Eng ; 45(9): 2109-2121, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28639171

RESUMO

Use of subject-specific axes of rotation may improve predictions generated by kinematic models, especially for joints with complex anatomy, such as the tibiotalar and subtalar joints of the ankle. The objective of this study was twofold. First, we compared the axes of rotation between generic and subject-specific ankle models for ten control subjects. Second, we quantified the accuracy of generic and subject-specific models for predicting tibiotalar and subtalar joint motion during level walking using inverse kinematics. Here, tibiotalar and subtalar joint kinematics measured in vivo by dual-fluoroscopy served as the reference standard. The generic model was based on a cadaver study, while the subject-specific models were derived from each subject's talus reconstructed from computed tomography images. The subject-specific and generic axes of rotation were significantly different. The average angle between the modeled axes was 12.9° ± 4.3° and 24.4° ± 5.9° at the tibiotalar and subtalar joints, respectively. However, predictions from both models did not agree well with dynamic dual-fluoroscopy data, where errors ranged from 1.0° to 8.9° and 0.6° to 7.6° for the generic and subject-specific models, respectively. Our results suggest that methods that rely on talar morphology to define subject-specific axes may be inadequate for accurately predicting tibiotalar and subtalar joint kinematics.


Assuntos
Articulação do Tornozelo , Modelos Biológicos , Tíbia , Adulto , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/fisiologia , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Amplitude de Movimento Articular/fisiologia , Tíbia/diagnóstico por imagem , Tíbia/fisiologia
13.
Gait Posture ; 55: 184-190, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28475981

RESUMO

Soft tissue movement between reflective skin markers and underlying bone induces errors in gait analysis. These errors are known as soft tissue artifact (STA). Prior studies have not examined how STA affects hip joint angles and range of motion (ROM) during dynamic activities. Herein, we: 1) measured STA of skin markers on the pelvis and thigh during walking, hip abduction and hip rotation, 2) quantified errors in tracking the thigh, pelvis and hip joint angles/ROM, and 3) determined whether model constraints on hip joint degrees of freedom mitigated errors. Eleven asymptomatic young adults were imaged simultaneously with retroreflective skin markers (SM) and dual fluoroscopy (DF), an X-ray technique with sub-millimeter and sub-degree accuracy. STA, defined as the range of SM positions in the DF-measured bone anatomical frame, varied based on marker location, activity and subject. Considering all skin markers and activities, mean STA ranged from 0.3cm to 5.4cm. STA caused the hip joint angle tracked with SM to be 1.9° more extended, 0.6° more adducted, and 5.8° more internally rotated than the hip tracked with DF. ROM was reduced for SM measurements relative to DF, with the largest difference of 21.8° about the internal-external axis during hip rotation. Constraining the model did not consistently reduce angle errors. Our results indicate STA causes substantial errors, particularly for markers tracking the femur and during hip internal-external rotation. This study establishes the need for future research to develop methods minimizing STA of markers on the thigh and pelvis.


Assuntos
Artefatos , Simulação por Computador , Marcha/fisiologia , Articulação do Quadril/fisiologia , Modelos Biológicos , Amplitude de Movimento Articular/fisiologia , Adulto , Feminino , Fluoroscopia , Humanos , Masculino , Pelve/fisiologia , Adulto Jovem
14.
Gait Posture ; 50: 246-251, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27693944

RESUMO

Hip joint center (HJC) measurement error can adversely affect predictions from biomechanical models. Soft tissue artifact (STA) may exacerbate HJC errors during dynamic motions. We quantified HJC error and the effect of STA in 11 young, asymptomatic adults during six activities. Subjects were imaged simultaneously with reflective skin markers (SM) and dual fluoroscopy (DF), an x-ray based technique with submillimeter accuracy that does not suffer from STA. Five HJCs were defined from locations of SM using three predictive (i.e., based on regression) and two functional methods; these calculations were repeated using the DF solutions. Hip joint center motion was analyzed during six degrees-of-freedom (default) and three degrees-of-freedom hip joint kinematics. The position of the DF-measured femoral head center (FHC), served as the reference to calculate HJC error. The effect of STA was quantified with mean absolute deviation. HJC errors were (mean±SD) 16.6±8.4mm and 11.7±11.0mm using SM and DF solutions, respectively. HJC errors from SM measurements were all significantly different from the FHC in at least one anatomical direction during multiple activities. The mean absolute deviation of SM-based HJCs was 2.8±0.7mm, which was greater than that for the FHC (0.6±0.1mm), suggesting that STA caused approximately 2.2mm of spurious HJC motion. Constraining the hip joint to three degrees-of-freedom led to approximately 3.1mm of spurious HJC motion. Our results indicate that STA-induced motion of the HJC contributes to the overall error, but inaccuracies inherent with predictive and functional methods appear to be a larger source of error.


Assuntos
Artefatos , Marcha/fisiologia , Articulação do Quadril/fisiologia , Adulto , Fenômenos Biomecânicos , Feminino , Cabeça do Fêmur , Fluoroscopia , Humanos , Masculino , Movimento (Física) , Ossos Pélvicos , Radiografia , Adulto Jovem
15.
Gait Posture ; 49: 136-143, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27414041

RESUMO

Evidence suggests that the tibiotalar and subtalar joints provide near six degree-of-freedom (DOF) motion. Yet, kinematic models frequently assume one DOF at each of these joints. In this study, we quantified the accuracy of kinematic models to predict joint angles at the tibiotalar and subtalar joints from skin-marker data. Models included 1 or 3 DOF at each joint. Ten asymptomatic subjects, screened for deformities, performed 1.0m/s treadmill walking and a balanced, single-leg heel-rise. Tibiotalar and subtalar joint angles calculated by inverse kinematics for the 1 and 3 DOF models were compared to those measured directly in vivo using dual-fluoroscopy. Results demonstrated that, for each activity, the average error in tibiotalar joint angles predicted by the 1 DOF model were significantly smaller than those predicted by the 3 DOF model for inversion/eversion and internal/external rotation. In contrast, neither model consistently demonstrated smaller errors when predicting subtalar joint angles. Additionally, neither model could accurately predict discrete angles for the tibiotalar and subtalar joints on a per-subject basis. Differences between model predictions and dual-fluoroscopy measurements were highly variable across subjects, with joint angle errors in at least one rotation direction surpassing 10° for 9 out of 10 subjects. Our results suggest that both the 1 and 3 DOF models can predict trends in tibiotalar joint angles on a limited basis. However, as currently implemented, neither model can predict discrete tibiotalar or subtalar joint angles for individual subjects. Inclusion of subject-specific attributes may improve the accuracy of these models.


Assuntos
Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/fisiologia , Fluoroscopia/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Amplitude de Movimento Articular/fisiologia , Articulação Talocalcânea/diagnóstico por imagem , Tálus/diagnóstico por imagem , Adulto , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Valores de Referência , Reprodutibilidade dos Testes
16.
J Biomech Eng ; 138(9)2016 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-27455417

RESUMO

Measurements of joint kinematics are essential to understand the pathomechanics of ankle disease and the effects of treatment. Traditional motion capture techniques do not provide measurements of independent tibiotalar and subtalar joint motion. In this study, high-speed dual fluoroscopy images of ten asymptomatic adults were acquired during treadmill walking at 0.5 m/s and 1.0 m/s and a single-leg, balanced heel-rise. Three-dimensional (3D) CT models of each bone and dual fluoroscopy images were used to quantify in vivo kinematics for the tibiotalar and subtalar joints. Dynamic tibiotalar and subtalar mean joint angles often exhibited opposing trends during captured stance. During both speeds of walking, the tibiotalar joint had significantly greater dorsi/plantarflexion (D/P) angular ROM than the subtalar joint while the subtalar joint demonstrated greater inversion/eversion (In/Ev) and internal/external rotation (IR/ER) than the tibiotalar joint. During balanced heel-rise, only D/P and In/Ev were significantly different between the tibiotalar and subtalar joints. Translational ROM in the anterior/posterior (AP) direction was significantly greater in the subtalar than the tibiotalar joint during walking at 0.5 m/s. Overall, our results support the long-held belief that the tibiotalar joint is primarily responsible for D/P, while the subtalar joint facilitates In/Ev and IR/ER. However, the subtalar joint provided considerable D/P rotation, and the tibiotalar joint rotated about all three axes, which, along with translational motion, suggests that each joint undergoes complex, 3D motion.


Assuntos
Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/fisiologia , Fluoroscopia/métodos , Imageamento Tridimensional/métodos , Amplitude de Movimento Articular/fisiologia , Articulação Talocalcânea/diagnóstico por imagem , Articulação Talocalcânea/fisiologia , Feminino , Humanos , Masculino , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Ann Biomed Eng ; 44(7): 2168-80, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26645080

RESUMO

Predictions from biomechanical models of gait may be sensitive to joint center locations. Most often, the hip joint center (HJC) is derived from locations of reflective markers adhered to the skin. Here, predictive techniques use regression equations of pelvic anatomy to estimate the HJC, whereas functional methods track motion of markers placed at the pelvis and femur during a coordinated motion. Skin motion artifact may introduce errors in the estimate of HJC for both techniques. Quantifying the accuracy of these methods is an area of open investigation. In this study, we used dual fluoroscopy (DF) (a dynamic X-ray imaging technique) and three-dimensional reconstructions from computed tomography images, to measure HJC locations in vivo. Using dual fluoroscopy as the reference standard, we then assessed the accuracy of three predictive and two functional methods. Eleven non-pathologic subjects were imaged with DF and reflective skin marker motion capture. Additionally, DF-based solutions generated virtual markers placed on bony landmarks, which were input to the predictive and functional methods to determine if estimates of the HJC improved. Using skin markers, functional methods had better mean agreement with the HJC measured by DF (11.0 ± 3.3 mm) than predictive methods (18.1 ± 9.5 mm); estimates from functional and predictive methods improved when using the DF-based solutions (1.3 ± 0.9 and 17.5 ± 8.6 mm, respectively). The Harrington method was the best predictive technique using both skin markers (13.2 ± 6.5 mm) and DF-based solutions (10.6 ± 2.5 mm). The two functional methods had similar accuracy using skin makers (11.1 ± 3.6 and 10.8 ± 3.2 mm) and DF-based solutions (1.2 ± 0.8 and 1.4 ± 1.0 mm). Overall, functional methods were superior to predictive methods for HJC estimation. However, the improvements observed when using the DF-based solutions suggest that skin motion artifact is a large source of error for the functional methods.


Assuntos
Fêmur/diagnóstico por imagem , Fêmur/fisiologia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiologia , Movimento/fisiologia , Adulto , Fenômenos Biomecânicos , Feminino , Fluoroscopia , Humanos , Masculino , Padrões de Referência
18.
Gait Posture ; 41(4): 888-93, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25864769

RESUMO

The relationship between altered tibiotalar and subtalar kinematics and development of ankle osteoarthritis is unknown, as skin marker motion analysis cannot measure articulations of each joint independently. Here, we quantified the accuracy and demonstrated the feasibility of high-speed dual fluoroscopy (DF) to measure and visualize the three-dimensional articulation (i.e., arthrokinematics) of the tibiotalar and subtalar joints. Metal beads were implanted in the tibia, talus and calcaneus of two cadavers. Three-dimensional surface models of the cadaver and volunteer bones were reconstructed from computed tomography images. A custom DF system was positioned adjacent to an instrumented treadmill. DF images of the cadavers were acquired during maximal rotation about three axes (dorsal-plantar flexion, inversion-eversion, internal-external rotation) and simulated gait (treadmill at 0.5 and 1.0 m/s). Positions of implanted beads were tracked using dynamic radiostereometric analysis (DRSA). Bead locations were also calculated using model-based markerless tracking (MBT) and compared, along with joint angles and translations, to DRSA results. The mean positional difference between DRSA and MBT for all frames defined bias; standard deviation of the difference defined precision. The volunteer was imaged with DF during treadmill gait. From these movements, joint kinematics and tibiotalar and subtalar bone-to-bone distance were calculated. The mean positional and rotational bias (±standard deviation) of MBT was 0.03±0.35 mm and 0.25±0.81°, respectively. Mean translational and rotational precision was 0.30±0.12 mm and 0.63±0.28°, respectively. With excellent measurement accuracy, DF and MBT may elucidate the kinematic pathways responsible for osteoarthritis of the tibiotalar and subtalar joints in living subjects.


Assuntos
Articulação do Tornozelo/fisiologia , Fluoroscopia/métodos , Imageamento Tridimensional , Movimento/fisiologia , Idoso de 80 Anos ou mais , Articulação do Tornozelo/diagnóstico por imagem , Fenômenos Biomecânicos , Cadáver , Simulação por Computador , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
19.
J Biomech ; 47(13): 3325-33, 2014 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-25189094

RESUMO

The hamstring muscles frequently suffer injury during high-speed running, though the factors that make an individual more susceptible to injury remain poorly understood. The goals of this study were to measure the musculotendon dimensions of the biceps femoris long head (BFlh) muscle, the hamstring muscle injured most often, and to use computational models to assess the influence of variability in the BFlh's dimensions on internal tissue strains during high-speed running. High-resolution magnetic resonance (MR) images were acquired over the thigh in 12 collegiate athletes, and musculotendon dimensions were measured in the proximal free tendon/aponeurosis, muscle and distal free tendon/aponeurosis. Finite element meshes were generated based on the average, standard deviation and range of BFlh dimensions. Simulation boundary conditions were defined to match muscle activation and musculotendon length change in the BFlh during high-speed running. Muscle and connective tissue dimensions were found to vary between subjects, with a coefficient of variation (CV) of 17±6% across all dimensions. For all simulations peak local strain was highest along the proximal myotendinous junction, which is where injury typically occurs. Model variations showed that peak local tissue strain increased as the proximal aponeurosis width narrowed and the muscle width widened. The aponeurosis width and muscle width variation models showed that the relative dimensions of these structures influence internal muscle tissue strains. The results of this study indicate that a musculotendon unit's architecture influences its strain injury susceptibility during high-speed running.


Assuntos
Músculo Esquelético/lesões , Músculo Esquelético/fisiopatologia , Corrida/fisiologia , Entorses e Distensões/patologia , Entorses e Distensões/fisiopatologia , Traumatismos dos Tendões/fisiopatologia , Tendões/fisiologia , Atletas , Tecido Conjuntivo/lesões , Tecido Conjuntivo/patologia , Feminino , Análise de Elementos Finitos , Humanos , Masculino , Músculo Esquelético/patologia , Traumatismos dos Tendões/patologia , Tendões/patologia
20.
Med Sci Sports Exerc ; 46(4): 776-86, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24145724

RESUMO

INTRODUCTION: Proximal biceps femoris musculotendon strain injury has been well established as a common injury among athletes participating in sports that require sprinting near or at maximum speed; however, little is known about the mechanisms that make this muscle tissue more susceptible to injury at faster speeds. PURPOSE: This study aimed to quantify localized tissue strain during sprinting at a range of speeds. METHODS: Biceps femoris long head (BFlh) musculotendon dimensions of 14 athletes were measured on magnetic resonance (MR) images and used to generate a finite-element computational model. The model was first validated through comparison with previous dynamic MR experiments. After validation, muscle activation and muscle-tendon unit length change were derived from forward dynamic simulations of sprinting at 70%, 85%, and 100% maximum speed and used as input to the computational model simulations. Simulations ran from midswing to foot contact. RESULTS: The model predictions of local muscle tissue strain magnitude compared favorably with in vivo tissue strain measurements determined from dynamic MR experiments of the BFlh. For simulations of sprinting, local fiber strain was nonuniform at all speeds, with the highest muscle tissue strain where injury is often observed (proximal myotendinous junction). At faster sprinting speeds, increases were observed in fiber strain nonuniformity and peak local fiber strain (0.56, 0.67, and 0.72 for sprinting at 70%, 85%, and 100% maximum speed). A histogram of local fiber strains showed that more of the BFlh reached larger local fiber strains at faster speeds. CONCLUSIONS: At faster sprinting speeds, peak local fiber strain, fiber strain nonuniformity, and the amount of muscle undergoing larger strains are predicted to increase, likely contributing to the BFlh muscle's higher injury susceptibility at faster speeds.


Assuntos
Simulação por Computador , Músculo Esquelético/lesões , Músculo Esquelético/fisiopatologia , Corrida/fisiologia , Entorses e Distensões/fisiopatologia , Traumatismos em Atletas/fisiopatologia , Tecido Conjuntivo/fisiopatologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Fibras Musculares Esqueléticas/fisiologia , Tendões/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA