J Cardiothorac Vasc Anesth ; 34(11): 3113-3124, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32144058

RESUMO

Pulmonary complications are common after cardiac surgery and are closely related to postoperative heart failure and adverse outcomes. Lung ultrasonography (LUS) is currently a widely accepted diagnostic approach with well-established methodology, nomenclature, accuracy, and prognostic value in numerous clinical conditions. The advantages of LUS are universally recognized and include bedside applicability, high diagnostic sensitivity and reproducibility, no radiation exposure, and low cost. However, routine perioperative ultrasonography during cardiac surgery generally is limited to echocardiography, diagnosis of pleural effusion, and as a diagnostic tool for postoperative complications in different organs, and few studies have explored the clinical outcomes in relation to LUS among cardiac patients. This narrative review presents the clinical evidence regarding LUS application in intensive care and during the perioperative period for cardiac surgery. Furthermore, this review describes the methodology and the diagnostic and prognostic accuracies of LUS. A summary of ongoing clinical trials evaluating the clinical outcomes related to LUS also is provided. Finally, this review discusses the rationale for upcoming clinical research regarding whether routine use of LUS can modify current intensive care practice and potentially affect the clinical outcomes after cardiac surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Pulmão , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Cuidados Críticos , Humanos , Pulmão/diagnóstico por imagem , Reprodutibilidade dos Testes , Ultrassonografia
2.
J Cardiothorac Vasc Anesth ; 34(4): 926-931, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31677921

RESUMO

OBJECTIVE: To test the hypothesis that a positive end-expiratory pressure test and the mini-fluid challenge predict fluid responsiveness in patients after off-pump coronary artery bypass grafting. DESIGN: Single-center pilot prospective observational study. SETTING: City Hospital #1 of Arkhangelsk, Russian Federation. PARTICIPANTS: Thirty-two adult patients after off-pump coronary artery surgery. INTERVENTIONS: To assess fluid responsiveness, after arrival to the intensive care unit, all patients received a test with increase in positive end-expiratory pressure from 5 to 20 cmH2O for 2 minutes, a mini-fluid challenge test with administration of crystalloids at 1.5 mL/kg during 2 minutes, and standard fluid challenge test using 7 mL/kg during 10 minutes. MEASUREMENTS AND MAIN RESULTS: The patients with an increase in cardiac index by ≥15% after a standard fluid challenge test were defined as fluid responders. According to receiver operating characteristic analysis, a decrease in mean arterial pressure exceeding 5 mmHg in 120 seconds of the positive end-expiratory pressure test identified fluid responsiveness with an area under the curve of 0.73 (p = 0.03). The reduction in pulse pressure and stroke volume variations by more than 2% during mini-fluid challenge test predicted positive response to fluid load with an area under the curve of 0.77 and 0.75, respectively (p < 0.05). CONCLUSION: Both the positive end-expiratory pressure test and the mini-fluid challenge test are feasible after off-pump coronary artery bypass grafting and can be used to predict fluid responsiveness in these patients.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea , Hidratação , Adulto , Pressão Sanguínea , Soluções Cristaloides , Hemodinâmica , Humanos , Curva ROC , Federação Russa , Volume Sistólico
3.
Front Med (Lausanne) ; 4: 132, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28848733

RESUMO

BACKGROUND: The early warning scores may increase the safety of perioperative period. The objective of this study was to assess the diagnostic and predictive role of Integrated Pulmonary Index (IPI) after off-pump coronary artery bypass grafting (OPCAB). MATERIALS AND METHODS: Forty adult patients undergoing elective OPCAB were enrolled into a single-center prospective observational study. We assessed respiratory function using IPI that includes oxygen saturation, end-tidal CO2, respiratory rate, and pulse rate. In addition, we evaluated blood gas analyses and hemodynamics, including ECG, invasive arterial pressure, and cardiac index. The measurements were performed after transfer to the intensive care unit, after spontaneous breathing trial and at 2, 6, 12, and 18 h after extubation. RESULTS AND DISCUSSION: The value of IPI registered during respiratory support correlated weakly with cardiac index (rho = 0.4; p = 0.04) and ScvO2 (rho = 0.4, p = 0.02). After extubation, IPI values decreased significantly, achieving a minimum by 18 h. The IPI value ≤9 at 6 h after extubation was a predictor of complicated early postoperative period (AUC = 0.71; p = 0.04) observed in 13 patients. CONCLUSION: In off-pump coronary surgery, the IPI decreases significantly after tracheal extubation and may predict postoperative complications.

4.
Front Med (Lausanne) ; 4: 31, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28377920

RESUMO

BACKGROUND: The discontinuation of mechanical ventilation after coronary surgery may prolong and significantly increase the load on intensive care unit personnel. We hypothesized that automated mode using INTELLiVENT-ASV can decrease duration of postoperative mechanical ventilation, reduce workload on medical staff, and provide safe ventilation after off-pump coronary artery bypass grafting (OPCAB). The primary endpoint of our study was to assess the duration of postoperative mechanical ventilation during different modes of weaning from respiratory support (RS) after OPCAB. The secondary endpoint was to assess safety of the automated weaning mode and the number of manual interventions to the ventilator settings during the weaning process in comparison with the protocolized weaning mode. MATERIALS AND METHODS: Forty adult patients undergoing elective OPCAB were enrolled into a prospective single-center study. Patients were randomized into two groups: automated weaning (n = 20) using INTELLiVENT-ASV mode with quick-wean option; and protocolized weaning (n = 20), using conventional synchronized intermittent mandatory ventilation (SIMV) + pressure support (PS) mode. We assessed the duration of postoperative ventilation, incidence and duration of unacceptable RS, and the load on medical staff. We also performed the retrospective analysis of 102 patients (standard weaning) who were weaned from ventilator with SIMV + PS mode based on physician's experience without prearranged algorithm. RESULTS AND DISCUSSION: Realization of the automated weaning protocol required change in respiratory settings in 2 patients vs. 7 (5-9) adjustments per patient in the protocolized weaning group. Both incidence and duration of unacceptable RS were reduced significantly by means of the automated weaning approach. The FiO2 during spontaneous breathing trials was significantly lower in the automated weaning group: 30 (30-35) vs. 40 (40-45) % in the protocolized weaning group (p < 0.01). The average time until tracheal extubation did not differ in the automated weaning and the protocolized weaning groups: 193 (115-309) and 197 (158-253) min, respectively, but increased to 290 (210-411) min in the standard weaning group. CONCLUSION: The automated weaning system after off-pump coronary surgery might provide postoperative ventilation in a more protective way, reduces the workload on medical staff, and does not prolong the duration of weaning from ventilator. The use of automated or protocolized weaning can reduce the duration of postoperative mechanical ventilation in comparison with non-protocolized weaning based on the physician's decision.

5.
J Clin Monit Comput ; 31(2): 361-370, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26951494

RESUMO

To evaluate the accuracy of estimated continuous cardiac output (esCCO) based on pulse wave transit time in comparison with cardiac output (CO) assessed by transpulmonary thermodilution (TPTD) in off-pump coronary artery bypass grafting (OPCAB). We calibrated the esCCO system with non-invasive (Part 1) and invasive (Part 2) blood pressure and compared with TPTD measurements. We performed parallel measurements of CO with both techniques and assessed the accuracy and precision of individual CO values and agreement of trends of changes perioperatively (Part 1) and postoperatively (Part 2). A Bland-Altman analysis revealed a bias between non-invasive esCCO and TPTD of 0.9 L/min and limits of agreement of ±2.8 L/min. Intraoperative bias was 1.2 L/min with limits of agreement of ±2.9 L/min and percentage error (PE) of 64 %. Postoperatively, bias was 0.4 L/min, limits of agreement of ±2.3 L/min and PE of 41 %. A Bland-Altman analysis of invasive esCCO and TPTD after OPCAB found bias of 0.3 L/min with limits of agreement of ±2.1 L/min and PE of 40 %. A 4-quadrant plot analysis of non-invasive esCCO versus TPTD revealed overall, intraoperative and postoperative concordance rate of 76, 65, and 89 %, respectively. The analysis of trending ability of invasive esCCO after OPCAB revealed concordance rate of 73 %. During OPCAB, esCCO demonstrated poor accuracy, precision and trending ability compared to TPTD. Postoperatively, non-invasive esCCO showed better agreement with TPTD. However, invasive calibration of esCCO did not improve the accuracy and precision and the trending ability of method.


Assuntos
Débito Cardíaco/fisiologia , Ponte de Artéria Coronária sem Circulação Extracorpórea , Monitorização Intraoperatória/métodos , Monitorização Fisiológica/métodos , Termodiluição/métodos , Idoso , Anestesia , Pressão Sanguínea , Determinação da Pressão Arterial , Calibragem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/instrumentação , Análise de Onda de Pulso , Reprodutibilidade dos Testes , Fatores de Tempo , Resistência Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA