Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Abdom Radiol (NY) ; 49(1): 312-319, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37978076

RESUMO

PURPOSE: To evaluate the diagnostic capabilities of a supplementary color ramped iodine density map compared to virtual monoenergetic images (VMIs) at 74 keV in the diagnosis of acute bowel ischemia (ABI). METHODS: Data for this study were prospectively gathered and retrospectively evaluated. Patients referred to the Department of Diagnostic Radiology between October 2020 and August 2022 on the suspicion of ABI and underwent surgery < 12 h following fast kV-switching venous phase abdominal dual-energy CT (DECT) were consecutively included. Images were evaluated by two board-certified radiologists and two radiology residents. First round included only 74 keV VMIs resembling conventional 120 kVp images, and the second round included a supplementary iodine density map. Readers were asked to register presence of ABI as well as their confidence in their diagnosis based on a 5-point Likert scale. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for each observer with the surgical findings as the gold-standard. McNemar's and Wilcoxon signed-rank test were used to compare registrations and diagnostic confidence across assessment rounds. RESULTS: A total of 29 patients resulting in 31 DECT scans were included. Fourteen cases of ischemic/necrotic bowel were reported following surgery. Sensitivity and NPV were decreased with the use of supplementary iodine map images compared to 120 kVp-like images without supplementary iodine map images for three of four observers (round 1 range: 71.4-92.9% and 78.0-94.8%; round 2 range: 57.1-78.6% and 70.1-83.3%, respectively), while specificity and PPV were increased for three of four observers (round 1 range: 64.7-94.1% and 67.4-93.1%; round 2 range: 88.2-94.1% and 73.8-91.1%, respectively). However, no significant difference in ABI diagnosis or diagnostic confidence was found (p-value range: 0.07-1.00 and 0.23-0.58, respectively). CONCLUSION: No significant difference for the diagnosis of ABI was found using supplementary iodine mapping. Our study may suggest a trend of increased specificity and decreased sensitivity, hence, the use of supplementary iodine mapping should be carefully considered.


Assuntos
Iodo , Isquemia Mesentérica , Humanos , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos , Valor Preditivo dos Testes , Isquemia , Meios de Contraste
2.
Diagnostics (Basel) ; 13(6)2023 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-36980376

RESUMO

A chest X-ray report is a communicative tool and can be used as data for developing artificial intelligence-based decision support systems. For both, consistent understanding and labeling is important. Our aim was to investigate how readers would comprehend and annotate 200 chest X-ray reports. Reports written between 1 January 2015 and 11 March 2022 were selected based on search words. Annotators included three board-certified radiologists, two trained radiologists (physicians), two radiographers (radiological technicians), a non-radiological physician, and a medical student. Consensus labels by two or more of the experienced radiologists were considered "gold standard". Matthew's correlation coefficient (MCC) was calculated to assess annotation performance, and descriptive statistics were used to assess agreement between individual annotators and labels. The intermediate radiologist had the best correlation to "gold standard" (MCC 0.77). This was followed by the novice radiologist and medical student (MCC 0.71 for both), the novice radiographer (MCC 0.65), non-radiological physician (MCC 0.64), and experienced radiographer (MCC 0.57). Our findings showed that for developing an artificial intelligence-based support system, if trained radiologists are not available, annotations from non-radiological annotators with basic and general knowledge may be more aligned with radiologists compared to annotations from sub-specialized medical staff, if their sub-specialization is outside of diagnostic radiology.

3.
Diagnostics (Basel) ; 12(12)2022 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-36553118

RESUMO

Consistent annotation of data is a prerequisite for the successful training and testing of artificial intelligence-based decision support systems in radiology. This can be obtained by standardizing terminology when annotating diagnostic images. The purpose of this study was to evaluate the annotation consistency among radiologists when using a novel diagnostic labeling scheme for chest X-rays. Six radiologists with experience ranging from one to sixteen years, annotated a set of 100 fully anonymized chest X-rays. The blinded radiologists annotated on two separate occasions. Statistical analyses were done using Randolph's kappa and PABAK, and the proportions of specific agreements were calculated. Fair-to-excellent agreement was found for all labels among the annotators (Randolph's Kappa, 0.40-0.99). The PABAK ranged from 0.12 to 1 for the two-reader inter-rater agreement and 0.26 to 1 for the intra-rater agreement. Descriptive and broad labels achieved the highest proportion of positive agreement in both the inter- and intra-reader analyses. Annotating findings with specific, interpretive labels were found to be difficult for less experienced radiologists. Annotating images with descriptive labels may increase agreement between radiologists with different experience levels compared to annotation with interpretive labels.

4.
Diagnostics (Basel) ; 12(7)2022 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-35885531

RESUMO

Obesity is a risk factor of chronic kidney disease (CKD), leading to alterations in the renal vascular structure. This study tested if renal vascular density and tortuosity was quantifiable in vivo in obese rats using microbubble-based super-resolution ultrasound imaging. The kidneys of two 11-week-old and two 20-week-old male obese Zucker rats were compared with age-matched male lean Zucker rats. The super-resolution ultrasound images were manually divided into inner medulla, outer medulla, and cortex, and each area was subdivided into arteries and veins. We quantified vascular density and tortuosity, number of detected microbubbles, and generated tracks. For comparison, we assessed glomerular filtration rate, albumin/creatinine ratio, and renal histology to evaluate CKD. The number of detected microbubbles and generated tracks varied between animals and significantly affected quantification of vessel density. In areas with a comparable number of tracks, density increased in the obese animals, concomitant with a decrease in glomerular filtration rate and an increase in albumin/creatinine ratio, but without any pathology in the histological staining. The results indicate that super-resolution ultrasound imaging can be used to quantify structural alterations in the renal vasculature. Techniques to generate more comparable number of microbubble tracks and confirmation of the findings in larger-scale studies are needed.

5.
Diagnostics (Basel) ; 12(3)2022 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-35328261

RESUMO

We assessed the correlation between liver fat percentage using dual-energy CT (DECT) and Hounsfield unit (HU) measurements in contrast and non-contrast CT. This study included 177 patients in two patient groups: Group A (n = 125) underwent whole body non-contrast DECT and group B (n = 52) had a multiphasic DECT including a conventional non-contrast CT. Three regions of interest were placed on each image series, one in the left liver lobe and two in the right to measure Hounsfield Units (HU) as well as liver fat percentage. Linear regression analysis was performed for each group as well as combined. Receiver operating characteristic (ROC) curve was generated to establish the optimal fat percentage threshold value in DECT for predicting a non-contrast threshold of 40 HU correlating to moderate-severe liver steatosis. We found a strong correlation between fat percentage found with DECT and HU measured in non-contrast CT in group A and B individually (R2 = 0.81 and 0.86, respectively) as well as combined (R2 = 0.85). No significant difference was found when comparing venous and arterial phase DECT fat percentage measurements in group B (p = 0.67). A threshold of 10% liver fat found with DECT had 95% sensitivity and 95% specificity for the prediction of a 40 HU threshold using non-contrast CT. In conclusion, liver fat quantification using DECT shows high correlation with HU measurements independent of scan phase.

6.
Ultrasonics ; 122: 106695, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35149256

RESUMO

Microbubble (MB) tracking plays an important role in ultrasound super-resolution imaging (SRI) by enabling velocity estimation and improving image quality. This work presents a new hierarchical Kalman (HK) tracker to achieve better performance at scenarios with high concentrations of MBs and high localization uncertainty. The method attempts to follow MBs with different velocity ranges using different Kalman filters. An extended simulation framework for evaluating trackers is also presented and used for comparison of the proposed HK tracker with the nearest-neighbor (NN) and Kalman (K) trackers. The HK tracks were most similar to the ground truth with the highest Jaccard similarity coefficient in 79% of the scenarios and the lowest root-mean-square error in 72% of the scenarios. The HK tracker reconstructed vessels with a more accurate diameter. In a scenario with an uncertainty of 51.2µm in MB localization, a vessel diameter of 250µm was estimated as 257µm by HK tracker, compared with 329µm and 389µm for the K and NN trackers. In the same scenario, the HK tracker estimated MB velocities with a relative bias down to 1.7% and a relative standard deviation down to 8.3%. Finally, the different tracking techniques were applied to in vivo data from rat kidneys, and trends similar to the simulations were observed. Conclusively, the results showed an improvement in tracking performance, when the HK tracker was employed in comparison with the NN and K trackers.

7.
Ultrasound Med Biol ; 48(2): 346-357, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34763906

RESUMO

Local pressure differences estimated using vector flow imaging (VFI) and direct catheterization in seven carotid bifurcation phantoms were compared with simulated pressure fields. VFI correlated strongly with simulated peak pressure differences (r = 0.99, p < 0.00001), with an average overestimation of 12.3 Pa (28.6%). The range between the lowest and highest pressure difference of VFI underestimated simulations by 4.6 Pa (8.06%; r = 0.99, p < 0.0001). The catheter method exhibited no correlation (r = -0.09, p = 0.85). Ten repeated measurements on one phantom revealed a small standard deviation (SD) for VFI (SD = 8.4%, mean estimated SD = 11.5%), but not for the catheter method (SD = 785.6%). An in vivo peak systolic pressure difference of 97.9 Pa (estimated SD = 30%) was measured using VFI in one healthy individual. This study indicates that VFI pressure difference estimation is feasible in phantoms and in vivo and realistic estimates of the SD can be attained from the data.


Assuntos
Artérias Carótidas , Pescoço , Velocidade do Fluxo Sanguíneo , Artérias Carótidas/diagnóstico por imagem , Imagens de Fantasmas , Ultrassonografia
8.
Ultrasound Int Open ; 7(2): E48-E54, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34804771

RESUMO

Purpose Continuous wave Doppler ultrasound is routinely used to detect cardiac valve stenoses. Vector flow imaging (VFI) is an angle-independent real-time ultrasound method that can quantify flow complexity. We aimed to evaluate if quantification of flow complexity could reliably assess valvular stenosis in pediatric patients. Materials and Methods Nine pediatric patients with echocardiographically confirmed valvular stenosis were included in the study. VFI and Doppler measurements were compared with transvalvular peak-to-peak pressure differences derived from invasive endovascular catheterization. Results Vector concentration correlated with the catheter measurements before intervention after exclusion of one outlier (r=-0.83, p=0.01), whereas the Doppler method did not (r=0.49, p=0.22). The change in vector concentration after intervention correlated strongly with the change in the measured catheter pressure difference (r=-0.86, p=0.003), while Doppler showed a tendency for a moderate correlation (r=0.63, p=0.07). Conclusion Transthoracic flow complexity quantification calculated from VFI data is feasible and may be useful for assessing valvular stenosis severity in pediatric patients.

9.
Acta Radiol ; 62(11): 1499-1514, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34791887

RESUMO

This review looks at highlights of the development in ultrasound, ranging from interventional ultrasound and Doppler to the newest techniques like contrast-enhanced ultrasound and elastography, and gives reference to some of the valuable articles in Acta Radiologica. Ultrasound equipment is now available in any size and for any purpose, ranging from handheld devices to high-end devices, and the scientific societies include ultrasound professionals of all disciplines publishing guidelines and recommendations. Interventional ultrasound is expanding the field of use of ultrasound-guided interventions into nearly all specialties of medicine, from ultrasound guidance in minimally invasive robotic procedures to simple ultrasound-guided punctures performed by general practitioners. Each medical specialty is urged to define minimum requirements for equipment, education, training, and maintenance of skills, also for medical students. The clinical application of contrast-enhanced ultrasound and elastography is a topic often seen in current research settings.


Assuntos
Publicações Periódicas como Assunto/história , Radiologia/história , Ultrassonografia/história , Catéteres , Meios de Contraste , Drenagem/história , Drenagem/instrumentação , Técnicas de Imagem por Elasticidade/história , Endossonografia/história , História do Século XX , História do Século XXI , Humanos , Biópsia Guiada por Imagem/história , Masculino , Próstata/diagnóstico por imagem , Reto/diagnóstico por imagem , Ultrassonografia Doppler/história , Ultrassonografia de Intervenção/história
10.
Neurol Int ; 13(3): 269-278, 2021 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-34201493

RESUMO

Volume flow estimation in the common carotid artery (CCA) can assess the absolute hemodynamic effect of a carotid stenosis. The aim of this study was to compare a commercial vector flow imaging (VFI) setup against the reference method magnetic resonance phase contrast angiography (MRA) for volume flow estimation in the CCA. Ten healthy volunteers were scanned with VFI and MRA over the CCA. VFI had an improved precision of 19.2% compared to MRA of 31.9% (p = 0.061). VFI estimated significantly lower volume flow than MRA (mean difference: 63.2 mL/min, p = 0.017), whilst the correlation between VFI and MRA was strong (R2 = 0.81, p < 0.0001). A Bland-Altman plot indicated a systematic bias. After bias correction, the percentage error was reduced from 41.0% to 25.2%. This study indicated that a VFI setup for volume flow estimation is precise and strongly correlated to MRA volume flow estimation, and after correcting for the systematic bias, VFI and MRA become interchangeable.

11.
Ugeskr Laeger ; 183(23)2021 06 07.
Artigo em Dinamarquês | MEDLINE | ID: mdl-34120684

RESUMO

Dual-energy CT (DECT) is an emerging imaging technique and has become increasingly available in Danish hospitals in recent years. DECT utilizes data acquired from high and low kV photons. This allows for the separation of materials based on their atomic buildup, which can be visualised and quantified during post-processing. DECT entails a broad range of clinical applications across multiple organ systems and can support diagnostic decision-making as described in this review. DECT is not yet widely utilised mainly due to limited knowledge combined with a new workflow for the radiologist.


Assuntos
Tomografia Computadorizada por Raios X , Humanos
12.
Diagnostics (Basel) ; 11(3)2021 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-33799729

RESUMO

The purpose of the study was to investigate whether Dual Energy CT (DECT) can be used as a diagnostic tool to assess the severity of acute pulmonary embolism (PE) by correlating parenchymal perfusion defect volume, obstruction score and right ventricular-to-left ventricular (RV/LV) diameter ratio using CT angiography (CTA) and DECT perfusion imaging. A total of 43 patients who underwent CTA and DECT perfusion imaging with clinical suspicion of acute PE were retrospectively included in the study. In total, 25 of these patients had acute PE findings on CTA. DECT assessed perfusion defect volume (PDvol) were automatically and semiautomatically quantified. Overall, two CTA methods for risk assessment in patients with acute PE were assessed: the RV/LV diameter ratio and the Modified Miller obstruction score. Automatic PDvol had a weak correlation (r = 0.47, p = 0.02) and semiautomatic PDvol (r = 0.68, p < 0.001) had a moderate correlation to obstruction score in patients with confirmed acute PE, while only semiautomatic PDvol (r = 0.43, p = 0.03) had a weak correlation with the RV/LV diameter ratio. Our data indicate that PDvol assessed by DECT software technique may be a helpful tool to assess the severity of acute PE when compared to obstruction score and RV/LV diameter ratio.

13.
Diagnostics (Basel) ; 11(1)2021 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-33445602

RESUMO

Blood flow is essential to life and intertwined with all processes in the human body [...].

14.
Diagnostics (Basel) ; 10(11)2020 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-33105888

RESUMO

In vivo monitoring of the microvasculature is relevant since diseases such as diabetes, ischemia, or cancer cause microvascular impairment. Super-resolution ultrasound imaging allows in vivo examination of the microvasculature by detecting and tracking sparsely distributed intravascular microbubbles over a minute-long period. The ability to create detailed images of the renal vasculature of Sprague-Dawley rats using a modified clinical ultrasound platform was investigated in this study. Additionally, we hypothesized that early ischemic damage to the renal microcirculation could be visualized. After a baseline scan of the exposed kidney, 10 rats underwent clamping of the renal vein (n = 5) or artery (n = 5) for 45 min. The kidneys were rescanned at the onset of clamp release and after 60 min of reperfusion. Using a processing pipeline for tissue motion compensation and microbubble tracking, super-resolution images with a very high level of detail were constructed. Image filtration allowed further characterization of the vasculature by isolating specific vessels such as the ascending vasa recta with a 15-20 µm diameter. Using the super-resolution images alone, it was only possible for six assessors to consistently distinguish the healthy renal microvasculature from the microvasculature at the onset of vein clamp release. Future studies will aim at attaining quantitative estimations of alterations in the renal microvascular blood flow using super-resolution ultrasound imaging.

15.
Diagnostics (Basel) ; 10(10)2020 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-33066281

RESUMO

Dual-energy computed tomography (DECT) can estimate tissue vascularity and perfusion via iodine quantification. The aim of this systematic review was to outline current and emerging clinical applications of iodine quantification within the gastrointestinal tract using DECT. The search was conducted with three databases: EMBASE, Pubmed and The Cochrane Library. This identified 449 studies after duplicate removal. From a total of 570 selected studies, 30 studies were enrolled for the systematic review. The studies were categorized into four main topics: gastric tumors (12 studies), colorectal tumors (8 studies), Crohn's disease (4 studies) and miscellaneous applications (6 studies). Findings included a significant difference in iodine concentration (IC) measurements in perigastric fat between T1-3 vs. T4 stage gastric cancer, poorly and well differentiated gastric and colorectal cancer, responders vs. non-responders following chemo- or chemoradiotherapy treatment among cancer patients, and a positive correlation between IC and Crohn's disease activity. In conclusion, iodine quantification with DECT may be used preoperatively in cancer imaging as well as for monitoring treatment response. Future studies are warranted to evaluate the capabilities and limitations of DECT in splanchnic flow.

16.
Diagnostics (Basel) ; 10(6)2020 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-32575759

RESUMO

Digital subtraction angiography (DSA) is considered the reference method for the assessment of carotid artery stenosis; however, the procedure is invasive and accompanied by ionizing radiation. Velocity estimation with duplex ultrasound (DUS) is widely used for carotid artery stenosis assessment since no radiation or intravenous contrast is required; however, the method is angle-dependent. Vector concentration (VC) is a parameter for flow complexity assessment derived from the angle independent ultrasound method vector flow imaging (VFI), and VC has shown to correlate strongly with stenosis degree. The aim of this study was to compare VC estimates and DUS estimated peak-systolic (PSV) and end-diastolic velocities (EDV) for carotid artery stenosis patients, with the stenosis degree obtained with DSA. Eleven patients with symptomatic carotid artery stenosis were examined with DUS, VFI, and DSA before and after stent treatment. Compared to DSA, VC showed a strong correlation (r = -0.79, p < 0.001), while PSV (r = 0.68, p = 0.002) and EDV (r = 0.51, p = 0.048) obtained with DUS showed a moderate correlation. VFI using VC calculations may be a useful ultrasound method for carotid artery stenosis and stent patency assessment.

17.
Ultrasound Med Biol ; 46(9): 2493-2504, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32595057

RESUMO

Non-invasive assessment is preferred for monitoring arteriovenous dialysis fistulas (AVFs). Vector concentration assesses flow complexity, which may correlate with stenosis severity. We determined whether vector concentration could assess stenosis severity in dysfunctional AVFs. Vector concentration was estimated in four stenotic phantoms at different pulse repetition frequencies. Spectral Doppler peak velocity and vector concentration were measured in 12 patients with dysfunctional AVFs. Additionally, 5 patients underwent digital subtraction angiography (DSA). In phantoms, vector concentration exhibited an inverse relationship with stenosis severity and was less affected by aliasing in severe stenoses. In nine stenoses of 5 patients undergoing DSA, vector concentration correlated strongly with stenosis severity (first stenosis: r = -0.73, p = 0.04; other stenoses; r = -0.69, p = 0.02) and mid-stenotic diameter (first stenosis: r = 0.87, p = 0.006; other stenoses: r = 0.70, p = 0.02) as opposed to peak velocities (p > 0.05). Vector concentration is less affected by aliasing in severe stenoses and correlates with DSA in patients with dysfunctional AVF.


Assuntos
Derivação Arteriovenosa Cirúrgica , Constrição Patológica/diagnóstico por imagem , Diálise Renal , Humanos , Imagens de Fantasmas , Reologia , Índice de Gravidade de Doença , Ultrassonografia Doppler
18.
Ugeskr Laeger ; 182(53)2020 12 28.
Artigo em Dinamarquês | MEDLINE | ID: mdl-33463517

RESUMO

Acute bowel ischaemia is potentially life-threatening and requires prompt intervention. CT is first-line modality for abdominal imaging in the acute setting. The dual-energy technique improves conspicuity and identification of intestinal ischaemia and bleeding. This is a case report of a 43-year-old male patient with gastrointestinal bleeding after primary abdominal surgery. Dual-energy CT was able to identify otherwise occult intestinal ischaemia besides ongoing bleeding.


Assuntos
Isquemia Mesentérica , Tomografia Computadorizada por Raios X , Abdome , Adulto , Hemorragia Gastrointestinal , Humanos , Isquemia/diagnóstico por imagem , Isquemia/cirurgia , Masculino , Isquemia Mesentérica/diagnóstico por imagem , Isquemia Mesentérica/cirurgia
19.
Ultrasound Med Biol ; 46(1): 64-72, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31677849

RESUMO

Aortic valve stenosis (AS) is treated with biological prostheses (BPs) and mechanical prostheses (MPs). Vector flow imaging (VFI), an angle-independent ultrasound method, can quantify flow complexity (vector concentration (VC)) and secondary rotation (SR). Ten patients (mean age: 70.7 y) with tricuspid AS scheduled for BPs, 10 patients (mean age: 56.2 y) with bicuspid AS scheduled for MPs and 10 patients (mean age: 63.9 y) with normal aortic valves were scanned intra-operatively on the ascending aorta with VFI and conventional spectral Doppler. Bicuspid AS (peak systolic velocity (PSV): 380.9 cm/s, SR: 16.7 Hz, VC: 0.21) had more complex flow (p < 0.02) than tricuspid AS (PSV: 346.1 cm/s, SR: 17.1 Hz, VC: 0.33). Both groups had more complex and faster flow (p < 0.0001) than normal aortic valve patients (PSV: 124.0 cm/s, SR: 4.3 Hz, VC: 0.79). VC (r = 0.87) and SR (r = 0.89) correlated to PSV. After surgery, flow parameters changed (p < 0.0001) for patients with MPs (PSV: 250.4 cm/s, SR: 9.8 Hz, VC: 0.54) and BPs (PSV: 232.4 cm/s, SR: 12.5 Hz, VC: 0.61), with MPs having slower SR (p < 0.01). None of the implants had normal flow (p < 0.0001). In conclusion, VFI can provide new flow parameters for AS and implant assessment.


Assuntos
Aorta/diagnóstico por imagem , Aorta/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/fisiopatologia , Estenose da Valva Tricúspide/diagnóstico por imagem , Estenose da Valva Tricúspide/fisiopatologia , Idoso , Aorta/cirurgia , Estenose da Valva Aórtica/cirurgia , Bioprótese , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Estenose da Valva Mitral/cirurgia , Fluxo Sanguíneo Regional , Estenose da Valva Tricúspide/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA