Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38718419

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the usefulness of the injection pressure-to-injection rate (IPIR) ratio for the early detection of contrast extravasation at the venipuncture site during contrast-enhanced computed tomography. METHODS: We retrospectively enrolled 57,528 patients who underwent contrast-enhanced computed tomography examinations in a single hospital. The power injector recorded the contrast injection pressure at 0.25-second intervals. We constructed logistic regression models using the IPIR ratio as the independent variable and extravasation occurrence as the dependent variable (IPIR ratio models) at 1, 2, 3, 4, 5, and 6 seconds after the start of contrast administration. Univariate logistic regression models in which injection pressure is used as an independent variable (injection pressure models) were also constructed as a reference baseline. The performance of the models was evaluated with the area under the receiver operating characteristic curves. RESULTS: Of the 57,528 cases, 46,022 were assigned to the training group and 11,506 were assigned to the test group, which included 112 extravasation cases (0.24%) in the training group and 28 (0.24%) in the test group. The area under the receiver operating characteristic curves for the IPIR ratio models and injection pressure models were 0.555 versus 0.563 at t = 1 (P = 0.270), 0.712 versus 0.678 at t = 2 (P = 0.305), 0.758 versus 0.693 at t = 3 (P = 0.032), 0.776 versus 0.688 at t = 4 (P = 0.005), 0.810 versus 0.699 at t = 5 (P = 0.002), and 0.811 versus 0.706 at t = 6 (P = 0.002). CONCLUSIONS: The IPIR ratio models perform better in detecting contrast extravasation at 3 to 6 seconds after the start of contrast administration than injection pressure models.

2.
Medicine (Baltimore) ; 103(20): e38295, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38758838

RESUMO

To assess the diagnostic performance of unenhanced electrocardiogram (ECG)-gated cardiac computed tomography (CT) for detecting myocardial edema, using MRI T2 mapping as the reference standard. This retrospective study protocol was approved by our institutional review board, which waived the requirement for written informed consent. Between December 2017 to February 2019, consecutive patients who had undergone T2 mapping for myocardial tissue characterization were identified. We excluded patients who did not undergo unenhanced ECG-gated cardiac CT within 3 months from MRI T2 mapping or who had poor CT image quality. All patients underwent unenhanced ECG-gated cardiac CT with an axial scan using a third-generation, 320 × 0.5 mm detector-row CT unit. Two radiologists together drew regions of interest (ROIs) in the interventricular septum on the unenhanced ECG-gated cardiac CT images. Using T2 mapping as the reference standard, the diagnostic performance of unenhanced cardiac CT for detecting myocardial edema was evaluated by using the area under the receiver operating characteristic curve with sensitivity and specificity. Youden index was used to find an optimal sensitivity-specificity cutoff point. A cardiovascular radiologist independently performed the measurements, and interobserver reliability was assessed using intraclass correlation coefficients for CT value measurements. A P value of <.05 was considered statistically significant. We included 257 patients who had undergone MRI T2 mapping. Of the 257 patients, 35 patients underwent unenhanced ECG-gated cardiac CT. One patient was excluded from the study because of poor CT image quality. Finally, 34 patients (23 men; age 64.7 ±â€…14.6 years) comprised our study group. Using T2 mapping, we identified myocardial edema in 19 patients. Mean CT and T2 values for 34 patients were 46.3 ±â€…2.7 Hounsfield unit and 49.0 ±â€…4.9 ms, respectively. Mean CT values moderately correlated with mean T2 values (Rho = -0.41; P < .05). Mean CT values provided a sensitivity of 63.2% and a specificity of 93.3% for detecting myocardial edema, with a cutoff value of ≤45.0 Hounsfield unit (area under the receiver operating characteristic curve = 0.77; P < .01). Inter-observer reproducibility in measuring mean CT values was excellent (intraclass correlation coefficient = 0.93; [95% confidence interval: 0.86, 0.96]). Myocardial edema could be detected by CT value of myocardium in unenhanced ECG-gated cardiac CT.


Assuntos
Eletrocardiografia , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Eletrocardiografia/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Imageamento por Ressonância Magnética/métodos , Sensibilidade e Especificidade , Reprodutibilidade dos Testes , Edema/diagnóstico por imagem , Edema Cardíaco/diagnóstico por imagem , Técnicas de Imagem de Sincronização Cardíaca/métodos , Curva ROC , Adulto
3.
Eur Radiol ; 33(12): 8488-8500, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37432405

RESUMO

OBJECTIVES: To evaluate the effect of super-resolution deep-learning-based reconstruction (SR-DLR) on the image quality of coronary CT angiography (CCTA). METHODS: Forty-one patients who underwent CCTA using a 320-row scanner were retrospectively included. Images were reconstructed with hybrid (HIR), model-based iterative reconstruction (MBIR), normal-resolution deep-learning-based reconstruction (NR-DLR), and SR-DLR algorithms. For each image series, image noise, and contrast-to-noise ratio (CNR) at the left main trunk, right coronary artery, left anterior descending artery, and left circumflex artery were quantified. Blooming artifacts from calcified plaques were measured. Image sharpness, noise magnitude, noise texture, edge smoothness, overall quality, and delineation of the coronary wall, calcified and noncalcified plaques, cardiac muscle, and valves were subjectively ranked on a 4-point scale (1, worst; 4, best). The quantitative parameters and subjective scores were compared among the four reconstructions. Task-based image quality was assessed with a physical evaluation phantom. The detectability index for the objects simulating the coronary lumen, calcified plaques, and noncalcified plaques was calculated from the noise power spectrum (NPS) and task-based transfer function (TTF). RESULTS: SR-DLR yielded significantly lower image noise and blooming artifacts with higher CNR than HIR, MBIR, and NR-DLR (all p < 0.001). The best subjective scores for all the evaluation criteria were attained with SR-DLR, with significant differences from all other reconstructions (p < 0.001). In the phantom study, SR-DLR provided the highest NPS average frequency, TTF50%, and detectability for all task objects. CONCLUSION: SR-DLR considerably improved the subjective and objective image qualities and object detectability of CCTA relative to HIR, MBIR, and NR-DLR algorithms. CLINICAL RELEVANCE STATEMENT: The novel SR-DLR algorithm has the potential to facilitate accurate assessment of coronary artery disease on CCTA by providing excellent image quality in terms of spatial resolution, noise characteristics, and object detectability. KEY POINTS: • SR-DLR designed for CCTA improved image sharpness, noise property, and delineation of cardiac structures with reduced blooming artifacts from calcified plaques relative to HIR, MBIR, and NR-DLR. • In the task-based image-quality assessments, SR-DLR yielded better spatial resolution, noise property, and detectability for objects simulating the coronary lumen, coronary calcifications, and noncalcified plaques than other reconstruction techniques. • The image reconstruction times of SR-DLR were shorter than those of MBIR, potentially serving as a novel standard-of-care reconstruction technique for CCTA performed on a 320-row CT scanner.


Assuntos
Aprendizado Profundo , Placa Aterosclerótica , Humanos , Angiografia por Tomografia Computadorizada , Estudos Retrospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Angiografia Coronária , Algoritmos
4.
Eur Radiol ; 33(5): 3253-3265, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36973431

RESUMO

OBJECTIVES: To evaluate the image quality of deep learning-based reconstruction (DLR), model-based (MBIR), and hybrid iterative reconstruction (HIR) algorithms for lower-dose (LD) unenhanced head CT and compare it with those of standard-dose (STD) HIR images. METHODS: This retrospective study included 114 patients who underwent unenhanced head CT using the STD (n = 57) or LD (n = 57) protocol on a 320-row CT. STD images were reconstructed with HIR; LD images were reconstructed with HIR (LD-HIR), MBIR (LD-MBIR), and DLR (LD-DLR). The image noise, gray and white matter (GM-WM) contrast, and contrast-to-noise ratio (CNR) at the basal ganglia and posterior fossa levels were quantified. The noise magnitude, noise texture, GM-WM contrast, image sharpness, streak artifact, and subjective acceptability were independently scored by three radiologists (1 = worst, 5 = best). The lesion conspicuity of LD-HIR, LD-MBIR, and LD-DLR was ranked through side-by-side assessments (1 = worst, 3 = best). Reconstruction times of three algorithms were measured. RESULTS: The effective dose of LD was 25% lower than that of STD. Lower image noise, higher GM-WM contrast, and higher CNR were observed in LD-DLR and LD-MBIR than those in STD (all, p ≤ 0.035). Compared with STD, the noise texture, image sharpness, and subjective acceptability were inferior for LD-MBIR and superior for LD-DLR (all, p < 0.001). The lesion conspicuity of LD-DLR (2.9 ± 0.2) was higher than that of HIR (1.2 ± 0.3) and MBIR (1.8 ± 0.4) (all, p < 0.001). Reconstruction times of HIR, MBIR, and DLR were 11 ± 1, 319 ± 17, and 24 ± 1 s, respectively. CONCLUSION: DLR can enhance the image quality of head CT while preserving low radiation dose level and short reconstruction time. KEY POINTS: • For unenhanced head CT, DLR reduced the image noise and improved the GM-WM contrast and lesion delineation without sacrificing the natural noise texture and image sharpness relative to HIR. • The subjective and objective image quality of DLR was better than that of HIR even at 25% reduced dose without considerably increasing the image reconstruction times (24 s vs. 11 s). • Despite the strong noise reduction and improved GM-WM contrast performance, MBIR degraded the noise texture, sharpness, and subjective acceptance with prolonged reconstruction times relative to HIR, potentially hampering its feasibility.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Humanos , Algoritmos , Aprendizado Profundo , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Cabeça/diagnóstico por imagem
5.
Acad Radiol ; 30(3): 431-440, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35738988

RESUMO

RATIONALE AND OBJECTIVES: To evaluate the image properties of lung-specialized deep-learning-based reconstruction (DLR) and its applicability in ultralow-dose CT (ULDCT) relative to hybrid- (HIR) and model-based iterative-reconstructions (MBIR). MATERIALS AND METHODS: An anthropomorphic chest phantom was scanned on a 320-row scanner at 50-mA (low-dose-CT 1 [LDCT-1]), 25-mA (LDCT-2), and 10-mA (ULDCT). LDCT were reconstructed with HIR; ULDCT images were reconstructed with HIR (ULDCT-HIR), MBIR (ULDCT-MBIR), and DLR (ULDCT-DLR). Image noise and contrast-to-noise ratio (CNR) were quantified. With the LDCT images as reference standards, ULDCT image qualities were subjectively scored on a 5-point scale (1 = substantially inferior to LDCT-2, 3 = comparable to LDCT-2, 5 = comparable to LDCT-1). For task-based image quality analyses, a physical evaluation phantom was scanned at seven doses to achieve the noise levels equivalent to chest phantom; noise power spectrum (NPS) and task-based transfer function (TTF) were evaluated. Clinical ULDCT (10-mA) images obtained in 14 nonobese patients were reconstructed with HIR, MBIR, and DLR; the subjective acceptability was ranked. RESULTS: Image noise was lower and CNR was higher in ULDCT-DLR and ULDCT-MBIR than in LDCT-1, LDCT-2, and ULDCT-HIR (p < 0.01). The overall quality of ULDCT-DLR was higher than of ULDCT-HIR and ULDCT-MBIR (p < 0.01), and almost comparable with that of LDCT-2 (mean score: 3.4 ± 0.5). DLR yielded the highest NPS peak frequency and TTF50% for high-contrast object. In clinical ULDCT images, the subjective acceptability of DLR was higher than of HIR and MBIR (p < 0.01). CONCLUSION: DLR optimized for lung CT improves image quality and provides possible greater dose optimization opportunity than HIR and MBIR.


Assuntos
Aprendizado Profundo , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Pulmão/diagnóstico por imagem , Algoritmos
6.
Eur J Radiol ; 151: 110280, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35381567

RESUMO

PURPOSE: This clinical and phantom study aimed to evaluate the impact of deep learning-based reconstruction (DLR) on image quality and its radiation dose optimization capability for multiphase hepatic CT relative to hybrid iterative reconstruction (HIR). METHODS: Task-based image quality was assessed with a physical evaluation phantom; the high- and low-contrast detectability of HIR and DLR images were computed from the noise power spectrum and task-based transfer function at five different size-specific dose estimate (SSDE) values in the range 5.3 to 18.0-mGy. For the clinical study, images of 73 patients who had undergone multiphase hepatic CT under both standard-dose (STD) and lower-dose (LD) examination protocols within a time interval of about four-months on average, were retrospectively examined. STD images were reconstructed with HIR, while LD with HIR (LD-HIR) and DLR (LD-DLR). SSDE, quantitative image noise, and contrast-to-noise ratio (CNR) were compared between protocols. The noise magnitude, noise texture, streak artifact, image sharpness, interface smoothness, and overall image quality were subjectively rated by two independent radiologists. RESULTS: In phantom study, the high- and low-contrast detectability of DLR images obtained at 5.3-mGy and 7.3-mGy, respectively, were slightly higher than those obtained with HIR at the STD protocol dose (18.0-mGy). In clinical study, LD-DLR yielded lower image noise, higher CNR, and higher subjective scores for all evaluation criteria than STD (all, p ≤ 0.05), despite having 52.8% lower SSDE (8.0 ± 2.5 vs. 16.8 ± 3.4-mGy). CONCLUSIONS: DLR improved the subjective and objective image quality of multiphase hepatic CT compared with HIR techniques, even at approximately half the radiation dose.


Assuntos
Aprendizado Profundo , Infecções Sexualmente Transmissíveis , Algoritmos , Humanos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
7.
Acad Radiol ; 29(10): 1555-1559, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35246376

RESUMO

RATIONALE AND OBJECTIVES: This study aimed to assess the effectiveness of practical preventive strategies (i.e., venous vulnerability assessment and prevention scan protocol rules) taken by our radiology team (radiology nurses, radiology technicians, radiologists) on reducing extravasation of contrast media (ECM) during CT. MATERIALS AND METHODS: A total of 73,931 patients who underwent contrast-enhanced CT scans between January 2013 and December 2019 were retrospectively included. Venous vulnerability assessment by the radiology team began in 2015, and prevention scan protocol rules for the prevention of ECM were added in 2017. We defined each period as follows: 2013-2014, no prevention (Period A); 2015-2016, early prevention (Period B, venous vulnerability assessment only); and 2017-2019: late prevention (Period C, venous vulnerability assessment with prevention scan protocol rules). The incident reports, radiology reports, and medical records of patients in whom ECM occurred were reviewed. We compared the frequency of ECM during each period. RESULTS: ECM occurred in 0.39% (292/73,931) of the patients. The frequencies of ECM for Periods A, B, and C were 0.62% (121/19,505), 0.43% (89/20,847), and 0.24% (82/33,579), respectively. There were significant differences in the frequencies of ECM among the three periods (Chi-squared test, p < 0.01). CONCLUSION: Implementation of venous vulnerability assessment and prevention scan protocol rules by a radiology team can be a practical and simple solution to reduce the risk of ECM during CT.


Assuntos
Meios de Contraste , Radiologia , Meios de Contraste/efeitos adversos , Extravasamento de Materiais Terapêuticos e Diagnósticos/prevenção & controle , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
8.
AJR Am J Roentgenol ; 219(2): 315-324, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35195431

RESUMO

BACKGROUND. Deep learning-based reconstruction (DLR) may facilitate CT radiation dose reduction, but a paucity of literature has compared lower-dose DLR images with standard-dose iterative reconstruction (IR) images or explored application of DLR to low-tube-voltage scanning in children. OBJECTIVE. The purpose of this study was to assess whether DLR can be used to reduce radiation dose while maintaining diagnostic image quality in comparison with hybrid IR (HIR) and model-based IR (MBIR) for low-tube-voltage pediatric CT. METHODS. This retrospective study included children 6 years old or younger who underwent contrast-enhanced 80-kVp CT with a standard-dose or lower-dose protocol. Standard images were reconstructed with HIR, and lower-dose images were reconstructed with HIR, MBIR, and DLR. Size-specific dose estimate (SSDE) was calculated for both protocols. Image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were quantified. Two radiologists independently evaluated noise magnitude, noise texture, streak artifact, edge sharpness, and overall quality. Interreader agreement was assessed, and mean values were calculated. To evaluate task-based object detection performance, a phantom was imaged with 80-kVp CT at six doses (SSDE, 0.6-5.3 mGy). Detectability index (d') was calculated from the noise power spectrum and task-based transfer function. Reconstruction methods were compared. RESULTS. Sixty-five children (mean age, 25.0 ± 25.2 months) who underwent CT with standard- (n = 31) or lower-dose (n = 34) protocol were included. SSDE was 54% lower for the lower-dose than for the standard-dose group (1.9 ± 0.4 vs 4.1 ± 0.8 mGy). Lower-dose DLR and MBIR yielded lower image noise and higher SNR and CNR than standard-dose HIR (p < .05). Interobserver agreement on subjective features ranged from a kappa coefficient of 0.68 to 0.78. The readers subjectively scored noise texture, edge sharpness, and overall quality lower for lower-dose MBIR than for standard-dose HIR (p < .001), though higher for lower-dose DLR than for standard-dose HIR (p < .001). In the phantom, DLR provided higher d' than HIR and MBIR at each dose. Object detectability was greater for 2.0-mGy DLR than for 4.0-mGy HIR for low-contrast (3.67 vs 3.57) and high-contrast (1.20 vs 1.04) objects. CONCLUSION. Compared with IR algorithms, DLR results in substantial dose reduction with preserved or even improved image quality for low-tube-voltage pediatric CT. CLINICAL IMPACT. Use of DLR at 80 kVp allows greater dose reduction for pediatric CT than do current IR techniques.


Assuntos
Aprendizado Profundo , Interpretação de Imagem Radiográfica Assistida por Computador , Algoritmos , Criança , Pré-Escolar , Redução da Medicação , Humanos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
9.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 77(10): 1186-1195, 2021.
Artigo em Japonês | MEDLINE | ID: mdl-34670926

RESUMO

When the fat-suppression technique was used in the MRI examinations of neck and extremities, incomplete regions of fat suppression were depicted frequently. These incomplete regions were caused by the non-uniform static magnetic field (B0). On the other hand, a non-uniform B0 caused banding artifacts using a balanced steady-state free precession (bSSFP) sequence. We investigated the prediction of incomplete regions of fat suppression using the banding artifacts of the bSSFP sequence. The fat-suppression techniques used in this study were the chemical shift selective and spectral adiabatic inversion recovery methods for turbo spin echo imaging. Using an oil bottle attached to a staple, the scan parameters of the bSSFP sequence were adjusted to overlap with the banding artifacts in the incomplete regions of fat suppression. The neck, ankle joint and femur of healthy volunteers were scanned using the obtained scan parameters, and a visual assessment was performed. As a result, the incomplete region of fat suppression matched the region of the banding artifact. We were able to predict the incomplete region of fat suppression using the banding artifacts of the bSSFP sequence. If the optimized bSSFP sequence is used as the localizer, we can assess the situation of incomplete fat suppression before the main scanning and reduce rescanning due to incomplete fat suppression.


Assuntos
Artefatos , Imageamento por Ressonância Magnética , Voluntários Saudáveis , Humanos
10.
Eur J Radiol ; 136: 109530, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33453570

RESUMO

PURPOSE: CT is considered the non-invasive gold standard for evaluating cardiac implantable electronic devices (CIEDs) lead perforation, but metal artifacts caused by the lead tip affect the image quality and make a definitive diagnosis challenging. We compared the performances of the metal artifact reduction (MAR) algorithm and the conventional algorithm for identification of the right ventricular (RV) lead tip position in cardiac CT studies of patients with CIEDs. METHOD: Forty-seven consecutive patients (26 men; age 70.3 ±â€¯15.4 years) with CIEDs underwent cardiac CT. Using the conventional and MAR algorithm, two image reconstructions were performed for each scan. We calculated the artifact index (AI) to assess the quantitative capability of the MAR algorithm for artifact reduction and visually assessed the RV lead tip position on both images as follows: non-perforation, perforation, and equivocal. RESULTS: The mean AIs were significantly lower with the MAR algorithm than with the conventional algorithm (96.7 ±â€¯40.1 HU vs. 284.6 ±â€¯134.1 HU, P < 0.001). Thirteen (27.7 %) patients were diagnosed as equivocal using the conventional algorithm but were diagnosed with perforation (2 patients) and non-perforation (11 patients) using the MAR algorithm (equivocal rate: 27.7 % vs. 0%, P < 0.001). Using the MAR algorithm, all cases were diagnosed with perforation (6 patients, 12.8 %) or non-perforation (41 patients, 87.2 %). CONCLUSIONS: The MAR algorithm effectively reduced metal artifacts and allowed us to diagnose the presence or absence of perforation in all cases, whereas definitive diagnosis was difficult with the use of conventional algorithm in 27.7 % of cases.


Assuntos
Artefatos , Metais , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Próteses e Implantes , Tomografia Computadorizada por Raios X
11.
Acad Radiol ; 28(5): e119-e126, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32402786

RESUMO

RATIONALE AND OBJECTIVES: To clarify the accuracy of two measurement methods for myocardial extracellular volume (ECV) quantification (ie, the standard subtraction method [ECVsub] and the dual-energy iodine method [ECViodine]) with the use of cardiac CT in comparison to cardiac magnetic resonance imaging (CMR) as a reference standard. MATERIALS AND METHODS: Equilibrium phase cardiac images of 21 patients were acquired with a dual-layer spectral detector CT and CMR, and the images were retrospectively analyzed. CT-ECV was calculated using ECVsub and ECViodine. The correlation between the ECV values measured by each method was assessed. Bland-Altman analysis was used to identify systematic errors and to determine the limits of agreement between the CT-ECV and CMR-ECV values. Root mean squared errors and residual values for the ECVsub and ECViodine were also assessed. RESULTS: The correlations between ECVsub and ECViodine for both septal and global measurement were r = 0.95 (p < 0.01) and 0.91 (p < 0.01), respectively, while those between the mean ECVsub and CMR-ECV were r = 0.90 (septal, p < 0.01) and 0.84 (global, p < 0.01), and those between ECViodine and CMR-ECV were r = 0.94 (septal, p < 0.01) and 0.95 (global, p < 0.01). Bland-Altman plots showed lower 95% limits of agreement between ECViodine and CMR-ECV compared with that between ECVsub and CMR-ECV in both septal and global measurement. The root mean squared error of ECVsub was higher than that of ECViodine. The mean residual value of ECVsub was significantly higher than that of ECViodine. CONCLUSION: ECViodine yielded more accurate myocardial ECV quantification than ECVsub, and provided a comparable ECV value to that obtained by CMR.


Assuntos
Iodo , Meios de Contraste , Humanos , Imageamento por Ressonância Magnética , Imagem Cinética por Ressonância Magnética , Miocárdio , Valor Preditivo dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
12.
Br J Radiol ; 91(1081): 20170285, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29076752

RESUMO

OBJECTIVE: Different CT scanners have different X-ray spectra and photon energies indicating that contrast enhancement vary among scanners. However, this issue has not been fully validated; therefore, we performed phantom and clinical studies to assess this difference. METHODS: Two scanners were used: scanner-A and scanner-B. In the phantom study, we compared the contrast enhancement between the scanners at tube voltage peaks of 80, 100 and 120 kVp. Then, we calculated the effective energies of the two CT scanners. In the clinical study, 40 patients underwent abdominal scanning with scanner-A and another 40 patients with scanner-B, with each group using the same scanning protocol. The contrast enhancement of abdominal organs was assessed quantitatively (based on the absolute difference between the attenuation of unenhanced scans and contrast-enhanced scans) and qualitatively. A two-tailed independent Student's t-test and or the Mann-Whitney U test were used to compare the discrepancies. RESULTS: In the phantom study, contrast enhancement for scanner-B was 36.9, 32.6 and 30.8% higher than that for scanner-A at 80, 100 and 120 kVp, respectively. The effective energies were higher for scanner-A than for scanner-B. In the quantitative analysis for the clinical study, scanner-B yielded significantly better contrast enhancement of the hepatic parenchyma, pancreas, kidney, portal vein and inferior vena cava compared with that of scanner-A. The mean visual scores for contrast enhancement were also significantly higher on images obtained by scanner-B than those by scanner-A. CONCLUSION: There were significant differences in contrast enhancement of the abdominal organs between the compared CT scanners from two different vendors even at the same scanning and contrast parameters. Advances in knowledge: Awareness of the impact of different X-ray energies on the resultant attenuation of contrast material is important when interpreting clinical CT images.


Assuntos
Radiografia Abdominal , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Intensificação de Imagem Radiográfica , Estudos Retrospectivos , Adulto Jovem
13.
Br J Radiol ; 91(1081): 20170541, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29072853

RESUMO

OBJECTIVE: We compared the effect of a dual-region-of-interest (ROI) bolus-tracking technique on interpatient variability of arterial contrast enhancement with that of the conventional bolus-tracking technique in coronary computed tomographic angiography (CTA) on a 320-row scanner. METHODS: This study included 100 patients who underwent coronary CTA using one of two protocols: (1) 50 patients underwent scanning using a conventional single-ROI bolus-tracking technique (P-single) with an ROI placed in the ascending aorta, and (2) 50 patients underwent scanning using a dual-ROI technique (P-dual) with two ROIs placed in the pulmonary trunk and the ascending aorta. CT attenuation in the ascending aorta and coronary arteries, and the interpatient variability were compared between the two scanning protocols. RESULTS: The mean CT attenuation of the ascending aorta and coronary arteries tended to be higher for P-dual than for P-single, but the difference was not significant (p = 0.08-0.30). The interpatient variability of contrast enhancement (SD of the CT attenuation) was significantly smaller for P-dual than for P-single (p < 0.01). CONCLUSION: The dual-ROI bolus-tracking technique can reduce interpatient variability of arterial contrast enhancement in coronary CTA on a 320-row scanner. Advances in knowledge: The use of a dual-ROI bolus-tracking technique can provide sufficient and consistent arterial enhancement of coronary CTA.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Intensificação de Imagem Radiográfica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Aorta/diagnóstico por imagem , Artefatos , Meios de Contraste , Feminino , Humanos , Iopamidol , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
14.
Magn Reson Med Sci ; 17(1): 35-41, 2018 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-28515409

RESUMO

PURPOSE: To evaluate the effect of a composite radiofrequency (RF) pulse on saturation recovery (SR) myocardial T1 mapping using a 3T MR system. MATERIALS AND METHODS: Phantom and in vivo studies were performed with a clinical 3T MR scanner. Accuracy and reproducibility of the SR T1 mapping using conventional and composite RF pulses were first compared in phantom experiments. An in vivo study was performed of 10 healthy volunteers who were imaged with conventional and composite RF pulse methods twice each. In vivo reproducibility of myocardial T1 value and the inter-segment variability were assessed. RESULTS: The phantom study revealed significant differences in the mean T1 values between the two methods, and the reproducibility for the composite RF pulse was significantly smaller than that for the conventional RF pulse. For both methods, the correlations of the reference and measured T1 values were excellent (r2 = 0.97 and 0.98 for conventional and composite RF pulses, respectively). The in vivo study showed that the mean T1 value for composite RF pulse was slightly lower than that for conventional RF pulse, but this difference was not significant (P = 0.06). The inter-segment variability for the composite RF pulse was significantly smaller than that for conventional RF pulse (P < 0.01). Inter-scan correlations of T1 measurements of the first and second scans were highly and weakly correlated to composite RF pulses (r = 0.83 and 0.29, respectively). CONCLUSION: SR T1 mapping using composite RF pulse provides accurate quantification of T1 values and can lessen measurement variability and enable reproducible T1 measurements.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Ondas de Rádio , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Reprodutibilidade dos Testes
15.
J Comput Assist Tomogr ; 41(3): 349-353, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28471868

RESUMO

OBJECTIVE: The aim of this study was to evaluate the effect of cardiac output (CO) on aortic peak enhancement using protocols with different contrast material (CM) injection durations. METHODS: We used a flow phantom that simulated the human circulatory system. Contrast material was injected at a rate of 4.0 mL/s for a period of 2.5, 5, 10, 15, or 20 seconds for a CO of 2.8, 4.2, and 5.6 L/min. Single-level serial computed tomography scans of the simulated aorta were acquired after the start of CM delivery, and aortic peak enhancement was recorded under the different injection protocols. RESULTS: Under a long injection duration protocol (20 seconds), a decrease in CO increased aortic peak enhancement proportionally (CO of 2.8 L/min, 420 Hounsfield units [HU]; CO of 4.2 L/min, 365 HU; CO of 5.6 L/min, 291 HU). However, this effect was decreased under shorter injection duration protocols (5, 10, and 15 seconds); under the shortest (2.5-second) injection duration protocol, a decrease in CO resulted in a decrease in aortic peak enhancement (CO of 2.8 L/min, 36 HU; CO of 4.2 L/min, 51 HU; CO of 5.6 L/min, 55 HU). CONCLUSIONS: The magnitude of the effect of CO on aortic peak enhancement depends on the CM injection duration.


Assuntos
Débito Cardíaco/fisiologia , Meios de Contraste/administração & dosagem , Iopamidol/administração & dosagem , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Aorta/fisiologia , Imagens de Fantasmas , Fatores de Tempo
16.
Phys Med ; 35: 50-58, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28254400

RESUMO

This study compared dosimetric properties among four commercial multi-detector CT (MDCT) scanners. The X-ray beam characteristics were obtained from photon intensity attenuation curves of aluminum and off-center ratio (OCR) profiles in air, which were measured with four commercial MDCT scanners. The absorbed dose for MDCT scanners was evaluated with Farmer ionization chamber measurements at the center and four peripheral points in the body- and head-type cylindrical water phantoms. Measured collected charge was converted to absorbed dose using a 60Co absorbed dose-to-water calibration factor and Monte Carlo (MC)-calculated correction factors. Four MDCT scanners were modeled to correspond with measured X-ray beam characteristics using GMctdospp (IMPS, Germany) software. Al half-value layers (Al-HVLs) with a body-bowtie filter determined from measured Al-attenuation curves ranged 7.2‒9.1mm at 120kVp and 6.1‒8.0mm at 100kVp. MC-calculated Al-HVLs and OCRs in air were in acceptable agreement within 0.5mm and 5% of measured values, respectively. The percentage difference between nominal and actual beam width was greater with decreasing collimation width. The absorbed doses for MDCT scanners at 120kVp ranged 5.1‒7.1mGy and 10.8‒17.5mGy per 100mAs at the center in the body- and head-type water phantoms, respectively. Measured doses at four peripheral points were within 5% agreement of MC-calculated values. The absorbed dose at the center in both water phantoms increased with decreasing Al-HVL for the same charge on the focus. In this study the X-ray beam characteristics and the absorbed dose were measured and compared with calculated values for four MDCT scanners.


Assuntos
Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/instrumentação , Algoritmos , Calibragem , Radioisótopos de Cobalto , Simulação por Computador , Modelos Teóricos , Método de Monte Carlo , Imagens de Fantasmas , Radiometria , Água , Raios X
17.
Acta Radiol Open ; 6(2): 2058460117693463, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28321330

RESUMO

BACKGROUND: An optimal metal artifact reduction (MAR) technique is needed for a reliable and accurate image-based diagnosis. PURPOSE: Using a 320-row scanner, we compared the dual-energy computed tomography (CT)-based monochromatic and the single-energy metal artifact reduction (SEMAR) techniques for CT venography (CTV) to identify the better imaging method for diagnosing deep vein thrombosis (DVT) in patients who had undergone knee replacement surgery. MATERIAL AND METHODS: Twenty-three consecutive patients with suspected DVT after unilateral knee replacement surgery underwent dual-energy CT (135/80 kVp). Monochromatic images of 35-135 keV were generated; the monochromatic image with the best signal-to-noise ratio (SNR) of the popliteal vein near the metal prosthesis were selected. The projection data of 80 kVp were reconstructed using MAR algorithm. The mean SNR ON MAR and the best SNR ON monochromatic images were compared. Two radiologists evaluated visualization of the metal artifacts on a four-point scale where 1 = extensive artifacts, 2 = strong artifacts, 3 = mild artifacts, and 4 = minimal artifacts. RESULTS: The mean SNR was significantly higher on the MAR than the monochromatic images (12.8 ± 4.7 versus 7.7 ± 5.1, P < 0.01) and the visual scores were significantly higher for MAR than monochromatic images (2.6 ± 0.8 versus 1.3 ± 0.4, P < 0.01). CONCLUSION: For CTV after knee replacement surgery, the MAR technique is superior to the monochromatic imaging technique.

18.
Eur Radiol ; 27(6): 2267-2274, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27718079

RESUMO

OBJECTIVE: To investigate the usefulness of modifying scanning parameters based on the size-specific dose estimate (SSDE) for a breast-dose reduction for chest CT. MATERIALS AND METHODS: We scanned 26 women with a fixed volume CT dose index (CTDIvol) (15 mGy) and another 26 with a fixed SSDE (15 mGy) protocol (protocol 1 and 2, respectively). In protocol 2, tube current was calculated based on the patient habitus obtained on scout images. We compared the mean breast dose and the inter-patient breast dose variability and performed linear regression analysis of the breast dose and the body mass index (BMI) of the two protocols. RESULTS: The mean breast dose was about 35 % lower under protocol 2 than protocol 1 (10.9 mGy vs. 16.8 mGy, p < 0.01). The inter-patient breast dose variability was significantly lower under protocol 2 than 1 (1.2 mGy vs. 2.5 mGy, p < 0.01). We observed a moderate negative correlation between the breast dose and the BMI under protocol 1 (r = 0.43, p < 0.01); there was no significant correlation (r = 0.06, p = 0.35) under protocol 2. CONCLUSION: The SSDE-based protocol achieved a reduction in breast dose and in inter-patient breast dose variability. KEY POINTS: • CT scan parameters can be modified based on the pre-scan SSDE. • The pre-scan SSDE is useful for a breast dose reduction. • The fixed SSDE protocol reduced individual variations in the breast dose.


Assuntos
Mama/efeitos da radiação , Radiografia Torácica/efeitos da radiação , Índice de Massa Corporal , Feminino , Humanos , Modelos Lineares , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Cintilografia , Tomografia Computadorizada por Raios X/métodos
19.
Eur Radiol ; 27(2): 812-820, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27240454

RESUMO

OBJECTIVES: We evaluated the effects of a low contrast material (CM) dose protocol using 80-kVp on the image quality of hepatic multiphasic CT scans acquired on a 320-row CT scanner. METHODS: We scanned 30 patients with renal insufficiency (eGFR < 45 mL/min/1.73 m2) using 80-kVp and a CM dose of 300mgI/kg. Another 30 patients without renal insufficiency (eGFR > 60 mL/min/1.73 m2) were scanned with the conventional 120-kVp protocol and the standard CM dose of 600mgI/kg. Quantitative image quality parameters, i.e. CT attenuation, image noise, and the contrast-to-noise ratio (CNR) were compared and the visual image quality was scored on a four-point scale. The volume CT dose index (CTDIvol) and the size-specific dose estimate (SSDE) recorded with the 80- and the 120-kVp protocols were also compared. RESULTS: Image noise and contrast enhancement were equivalent for the two protocols. There was no significant difference in the CNR of all anatomic sites and in the visual scores for overall image quality. The CTDIvol and SSDE were approximately 25-30 % lower under the 80-kVp protocol. CONCLUSION: Hepatic multiphase CT using 80-kVp on a 320-row CT scanner allowed for a decrease in the CM dose and a reduction in the radiation dose without image quality degradation in patients with renal insufficiency. KEY POINTS: • The 80-kVp CT protocol enabled reduction of contrast dose by 50 % • The 80-kVp CT protocol reduced the radiation dose by 25-33 % • There was no degradation in the image quality of the 80-kVp protocol.


Assuntos
Injúria Renal Aguda/prevenção & controle , Meios de Contraste/administração & dosagem , Fígado/diagnóstico por imagem , Doses de Radiação , Insuficiência Renal , Tomografia Computadorizada por Raios X/métodos , Injúria Renal Aguda/induzido quimicamente , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Meios de Contraste/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Intensificação de Imagem Radiográfica , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
20.
Radiol Phys Technol ; 9(1): 44-52, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26290269

RESUMO

Practical simulations of low-dose CT images have a possibility of being helpful means for optimization of the CT exposure dose. Because current methods reported by several researchers are limited to specific vendor platforms and generally rely on raw sinogram data that are difficult to access, we have developed a new computerized scheme for producing simulated low-dose CT images from real high-dose images without use of raw sinogram data or of a particular phantom. Our computerized scheme for low-dose CT simulation was based on the addition of a simulated noise image to a real high-dose CT image reconstructed by the filtered back-projection algorithm. First, a sinogram was generated from the forward projection of a high-dose CT image. Then, an additional noise sinogram resulting from use of a reduced exposure dose was estimated from a predetermined noise model. Finally, a noise CT image was reconstructed with a predetermined filter and was added to the real high-dose CT image to create a simulated low-dose CT image. The noise power spectrum and modulation transfer function of the simulated low-dose images were very close to those of the real low-dose images. In order to confirm the feasibility of our method, we applied this method to clinical cases which were examined with the high dose initially and then followed with a low-dose CT. In conclusion, our proposed method could simulate the low-dose CT images from their real high-dose images with sufficient accuracy and could be used for determining the optimal dose setting for various clinical CT examinations.


Assuntos
Simulação por Computador , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/instrumentação , Processamento de Imagem Assistida por Computador , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA