Front Cardiovasc Med ; 11: 1392264, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38737710

RESUMO

We present a case of a 32-year-old male with a history of palpitations and preexcitation on ECG who underwent altogether four failed catheter ablations using different approaches in the two other electrophysiology centers within two years. ECG showed overt preexcitation with a positive delta wave in lead I and negative in leads V1-V3, suggesting a right free wall accessory pathway. During the electrophysiological study, the accessory pathway was localized on the free lateral wall. However, the electrograms and mapping during atrial and ventricular pacing suggested the presence of true epicardial accessory pathway. Repeated radiofrequency energy delivery with the support of the steerable sheath and excellent contact (as assessed by intracardiac echocardiography) at the earliest ventricular activation was not successful. Therefore, the Farawave catheter (Boston Scientific, Inc) was used, and a flower configuration with the intention to cover the entire atrial attachment of the pathway during ventricular pacing was selected. Application of pulsed field resulted in interruption of accessory pathway conduction. An electrophysiological study one year later confirmed the persistent effect of ablation. This case illustrates the potential utility of pulsed field energy for the ablation of atrial insertion of the accessory pathway with an epicardial course. Such an approach can avoid epicardial mapping and access and may improve the safety of the procedure.

2.
Eur J Intern Med ; 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38697863

RESUMO

BACKGROUND: Data on the clinical significance of iron deficiency (ID) in patients with myocardial infarction (MI) are conflicting. This may be related to the use of various ID criteria. We aimed to compare the association of different ID criteria with all-cause mortality after MI. METHODS: Consecutive patients hospitalized for their first MI at a large tertiary heart center were included. We evaluated the association of different iron metabolism parameters measured on the first day after hospital admission with all-cause mortality. RESULTS: From the 1,156 patients included (aged 64±12 years, 25 % women), 194 (16.8 %) patients died during the median follow-up of 3.4 years. After multivariate adjustment, iron level ≤13 µmol/L (HR 1.67, 95 % CI 1.19-2.34) and the combination of iron level ≤12.8 µmol/L and soluble transferrin receptor (sTfR) ≥3 mg/L (HR 2.56, 95 % CI 1.64-3.99) termed as PragueID criteria were associated with increased mortality risk and had additional predictive value to the GRACE score. Compared to the model including iron level, the addition of sTfR improved risk stratification (net reclassification improvement 0.61, 95 % CI 0.52-0.69) by reclassifying patients into a higher-risk group. No association between ferritin level and mortality was found. 51 % of patients had low iron levels, and 58 % fulfilled the PragueID criteria. CONCLUSION: Iron deficiency is common among patients with the first MI. The PragueID criteria based on iron and soluble transferrin receptor levels provide the best prediction of mortality and should be evaluated in future interventional studies for the identification of patients potentially benefiting from intravenous iron therapy.

3.
Nat Med ; 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38760584

RESUMO

Clinical outcomes of catheter ablation for atrial fibrillation (AF) are suboptimal due, in part, to challenges in achieving durable lesions. Although focal point-by-point ablation allows for the creation of any required lesion set, this strategy necessitates the generation of contiguous lesions without gaps. A large-tip catheter, capable of creating wide-footprint ablation lesions, may increase ablation effectiveness and efficiency. In a randomized, single-blind, non-inferiority trial, 420 patients with persistent AF underwent ablation using a large-tip catheter with dual pulsed field and radiofrequency energies versus ablation using a conventional radiofrequency ablation system. The primary composite effectiveness endpoint was evaluated through 1 year and included freedom from acute procedural failure and repeat ablation at any time, plus arrhythmia recurrence, drug initiation or escalation or cardioversion after a 3-month blanking period. The primary safety endpoint was freedom from a composite of serious procedure-related or device-related adverse events. The primary effectiveness endpoint was observed for 73.8% and 65.8% of patients in the investigational and control arms, respectively (P < 0.0001 for non-inferiority). Major procedural or device-related complications occurred in three patients in the investigational arm and in two patients in the control arm (P < 0.0001 for non-inferiority). In a secondary analysis, procedural times were shorter in the investigational arm as compared to the control arm (P < 0.0001). These results demonstrate non-inferior safety and effectiveness of the dual-energy catheter for the treatment of persistent AF. Future large-scale studies are needed to gather real-world evidence on the impact of the focal dual-energy lattice catheter on the broader population of patients with AF. ClinicalTrials.gov identifier: NCT05120193 .

4.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584468

RESUMO

AIMS: Pulsed field ablation (PFA) has significant advantages over conventional thermal ablation of atrial fibrillation (AF). This first-in-human, single-arm trial to treat paroxysmal AF (PAF) assessed the efficiency, safety, pulmonary vein isolation (PVI) durability and one-year clinical effectiveness of an 8 Fr, large-lattice, conformable single-shot PFA catheter together with a dedicated electroanatomical mapping system. METHODS AND RESULTS: After rendering the PV anatomy, the PFA catheter delivered monopolar, biphasic pulse trains (5-6 s per application; ∼4 applications per PV). Three waveforms were tested: PULSE1, PULSE2, and PULSE3. Follow-up included ECGs, Holters at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy endpoints were acute PVI and post-blanking atrial arrhythmia recurrence, respectively. Invasive remapping was conducted ∼75 days post-ablation. At three centres, PVI was performed by five operators in 85 patients using PULSE1 (n = 30), PULSE2 (n = 20), and PULSE3 (n = 35). Acute PVI was achieved in 100% of PVs using 3.9 ± 1.4 PFA applications per PV. Overall procedure, transpired ablation, PFA catheter dwell and fluoroscopy times were 56.5 ± 21.6, 10.0 ± 6.0, 19.1 ± 9.3, and 5.7 ± 3.9 min, respectively. No pre-defined primary safety events occurred. Upon remapping, PVI durability was 90% and 99% on a per-vein basis for the total and PULSE3 cohort, respectively. The Kaplan-Meier estimate of one-year freedom from atrial arrhythmias was 81.8% (95% CI 70.2-89.2%) for the total, and 100% (95% CI 80.6-100%) for the PULSE3 cohort. CONCLUSION: Pulmonary vein isolation (PVI) utilizing a conformable single-shot PFA catheter to treat PAF was efficient, safe, and effective, with durable lesions demonstrated upon remapping.


Assuntos
Fibrilação Atrial , Cateteres Cardíacos , Ablação por Cateter , Veias Pulmonares , Recidiva , Humanos , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Ablação por Cateter/métodos , Ablação por Cateter/instrumentação , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Desenho de Equipamento , Técnicas Eletrofisiológicas Cardíacas , Fatores de Tempo , Frequência Cardíaca , Potenciais de Ação
5.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38646926

RESUMO

AIMS: Using thermal-based energy sources [radiofrequency (RF) energy/cryo energy] for catheter ablation is considered effective and safe when performing pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (AF). However, treatment success remains limited and complications can occur due to the propagation of thermal energy into non-target tissues. We aim to compare pulsed field ablation (PFA) with RF ablation in terms of efficacy and safety for patients with drug-resistant paroxysmal AF. METHODS AND RESULTS: The BEAT PAROX-AF trial is a European multicentre, superiority, open-label randomized clinical trial in two parallel groups. A total of 292 participants were recruited in 9 high-volume European clinical centres in 5 countries. Patients with paroxysmal AF were randomized to PFA (FARAPULSE Endocardial Ablation System©, Boston Scientific) or RF using the CLOSE protocol with contact force sensing catheter (SmartTouch© catheter and CARTO© Biosense Webster). The primary endpoint will be the 1-year recurrence of atrial arrhythmia, and the major secondary safety endpoint will be the occurrence of acute (<7 days) procedure-related serious adverse events, or pulmonary vein stenosis, or atrio-oesophageal fistula up to 12 months. Additionally, five sub-studies investigate the effect of PFA on oesophageal safety, cerebral lesions, cardiac autonomic nervous system, durability of PVI as assessed during redo ablation procedures, and atrial and ventricular function. The study began on 27 December 2021 and concluded recruitment on 17 January 2024. Results will be available in mid-2025. CONCLUSION: The BEAT PAROX-AF trial aims to provide critical insights into the optimal treatment approach for patients with paroxysmal AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Resultado do Tratamento , Veias Pulmonares/cirurgia , Feminino , Masculino , Recidiva , Europa (Continente) , Pessoa de Meia-Idade
7.
Clin Transplant ; 38(3): e15275, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38477134

RESUMO

BACKGROUND: There is conflicting evidence on the role of acetylsalicylic acid (ASA) use in the development of cardiac allograft vasculopathy (CAV). METHODS: A nationwide prospective two-center study investigated changes in the coronary artery vasculature by highly automated 3-D optical coherence tomography (OCT) analysis at 1 month and 12 months after heart transplant (HTx). The influence of ASA use on coronary artery microvascular changes was analyzed in the overall study cohort and after propensity score matching for selected clinical CAV risk factors. RESULTS: In total, 175 patients (mean age 52 ± 12 years, 79% male) were recruited. During the 1-year follow-up, both intimal and media thickness progressed, with ASA having no effect on its progression. However, detailed OCT analysis revealed that ASA use was associated with a lower increase in lipid plaque (LP) burden (p = .013), while it did not affect the other observed pathologies. Propensity score matching of 120 patients (60 patient pairs) showed similar results, with ASA use associated with lower progression of LPs (p = .002), while having no impact on layered fibrotic plaque (p = .224), calcification (p = .231), macrophage infiltration (p = .197), or the absolute coronary artery risk score (p = .277). According to Kaplan-Meier analysis, ASA use was not associated with a significant difference in survival (p = .699) CONCLUSION: This study showed a benefit of early ASA use after HTx on LP progression. However, ASA use did not have any impact on the progression of other OCT-observed pathologies or long-term survival.


Assuntos
Doença da Artéria Coronariana , Transplante de Coração , Placa Aterosclerótica , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Feminino , Doença da Artéria Coronariana/etiologia , Estudos Prospectivos , Tomografia de Coerência Óptica/efeitos adversos , Tomografia de Coerência Óptica/métodos , Aloenxertos/patologia , Placa Aterosclerótica/complicações , Transplante de Coração/efeitos adversos , Angiografia Coronária
8.
Artigo em Inglês | MEDLINE | ID: mdl-38430087

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) alone is insufficient to treat many patients with persistent atrial fibrillation (PersAF). Adjunctive left atrial posterior wall (LAPW) ablation with thermal technologies has revealed lack of efficacy, perhaps limited by the difficulty in achieving lesion durability amid concerns of esophageal injury. OBJECTIVES: This study aims to compare the safety and effectiveness of PVI + LAPW ablation vs PVI in patients with PersAF using pulsed-field ablation (PFA). METHODS: In a retrospective analysis of the MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-approval Clinical Use of Pulsed Field Ablation) registry, we studied consecutive PersAF patients undergoing post-approval treatment with a pentaspline PFA catheter. The primary effectiveness outcome was freedom from any atrial arrhythmia of ≥30 seconds. Safety outcomes included the composite of acute and chronic major adverse events. RESULTS: Of the 547 patients with PersAF who underwent PFA, 131 (24%) received adjunctive LAPW ablation. Compared to PVI-alone, patients receiving adjunctive LAPW ablation were younger (65 vs 67 years of age, P = 0.08), had a lower CHA2DS2-VASc score (2.3 ± 1.6 vs 2.6 ± 1.6, P = 0.08), and were more likely to receive electroanatomical mapping (48.1% vs 39.0%, P = 0.07) and intracardiac echocardiography imaging (46.1% vs 17.1%, P < 0.001). The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmias was not statistically different between groups in the full (PVI + LAPW: 66.4%; 95% CI: 57.6%-74.4% vs PVI: 73.1%; 95% CI: 68.5%-77.2%; P = 0.68) and propensity-matched cohorts (PVI + LAPW: 71.7% vs PVI: 68.5%; P = 0.34). There was also no significant difference in major adverse events between the groups (2.2% vs 1.4%, respectively, P = 0.51). CONCLUSIONS: In patients with PersAF undergoing PFA, as compared to PVI-alone, adjunctive LAPW ablation did not improve freedom from atrial arrhythmia at 12 months.

9.
Eur J Prev Cardiol ; 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38497201

RESUMO

AIMS: While heart failure (HF) symptoms are associated with adverse prognosis after myocardial infarction (MI), they are not routinely used for patients' stratification. The primary objective of this study was to develop and validate a score to predict mortality risk after MI, combining remotely recorded HF symptoms and clinical risk factors, and to compare it against the guideline-recommended GRACE score. METHODS: A cohort study design using prospectively collected data from consecutive patients hospitalized for MI at a large tertiary heart centre between June 2017 and September 2022 was used. RESULTS: Data from 1,135 patients (aged 64±12 years, 26.7% women), were split into derivation (70%) and validation cohort (30%). Components of the 23-item Kansas City Cardiomyopathy Questionnaire (KCCQ) questionnaire and clinical variables were used as possible predictors. The best model included the following variables - age, heart failure history, admission creatinine and heart rate, ejection fraction at hospital discharge, and HF symptoms 1 month after discharge including walking impairment, leg swelling, and change in HF symptoms. Based on these variables, the PragueMi score was developed. In the validation cohort, the PragueMi score showed superior discrimination to the GRACE score for 6 months (AUC 90.1, 95% CI 81.8-98.4 vs. 77.4, 95% CI 62.2-92.5, p=0.04) and 1-year risk prediction (AUC 89.7, 95% CI 83.5-96.0 vs. 76.2, 95% CI 64.7-87.7, p=0.004). CONCLUSION: The PragueMi score combining heart failure symptoms and clinical variables performs better than the currently recommended GRACE score.


The prognosis of patients after myocardial infarction is heterogeneous. Thus, risk stratification is needed to identify and intervene patients at increased risk. While heart failure (HF) symptoms are associated with adverse prognosis, they are not used for patients' stratification. We have developed and internally validated the PragueMi score, which integrates clinical risk factors at the time of hospitalization and HF symptoms determined remotely by a questionnaire 1 month after hospital discharge. PragueMi score was able to better stratify patients' risk as compared to the currently recommended GRACE score.

10.
Europace ; 26(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38385529

RESUMO

AIMS: Pulmonary vein isolation (PVI) is a well-established strategy for the treatment of paroxysmal atrial fibrillation (PAF). Despite randomized controlled trials and real-world data showing the promise of pulsed-field ablation (PFA) for this treatment, long-term efficacy and safety data demonstrating single-procedure outcomes off antiarrhythmic drugs remain limited. The aim of the FARA-Freedom Study was to evaluate the long-term efficacy and safety of PFA using the pentaspline catheter for PAF. METHODS AND RESULTS: FARA-Freedom, a prospective, non-randomized, multicentre study, enrolled patients with PAF undergoing de novo PVI with PFA, who were followed for 12 months with weekly transtelephonic monitoring and a 72-h Holter ECG at 6 and 12 months. The primary safety endpoint was a composite of device- or procedure-related serious adverse events out to 7 days post-ablation and PV stenosis or atrioesophageal (AE) fistula out to 12 months. Treatment success is a composite of acute PVI and chronic success, which includes freedom from any documented atrial tachyarrhythmia longer than 30 s, use of antiarrhythmic drugs or cardioversion after a 3-month blanking period, or use of amiodarone or repeat ablation at any time. The study enrolled 179 PAF patients (62 ± 10 years, 39% female) at 13 centres. At the index procedure, all PVs were successfully isolated with the pentaspline PFA catheter. Procedure and left atrial dwell times, with a 20-min waiting period, were 71.9 ± 17.6 and 41.0 ± 13.3 min, respectively. Fluoroscopy time was 11.5 ± 7.4 min. Notably, monitoring compliance was high, with 88.4 and 90.3% with weekly events and 72-h Holter monitors, respectively. Freedom from the composite primary effectiveness endpoint was 66.6%, and 41 patients had atrial tachyarrhythmia recurrence, mostly recurrent atrial fibrillation (31 patients). The composite safety endpoint occurred in two patients (1.1%), one tamponade and one transient ischaemic attack. There was no coronary spasm, PV stenosis, or AE fistula. There were four cases of transient phrenic nerve palsy, but all resolved during the index procedure. CONCLUSION: In this prospective, non-randomized, multicentre study, PVI using a pentaspline PFA catheter was effective in treating PAF patients despite rigourous endpoint definitions and high monitoring compliance and demonstrated favourable safety. REGISTRATION: Clinical Trials.gov Identifier: NCT05072964 (sponsor: Boston Scientific Corporation).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fístula , Veias Pulmonares , Feminino , Humanos , Masculino , Antiarrítmicos , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Constrição Patológica/cirurgia , Fístula/cirurgia , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Taquicardia/cirurgia , Resultado do Tratamento , Pessoa de Meia-Idade , Idoso
11.
JACC Clin Electrophysiol ; 10(4): 654-666, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38385912

RESUMO

BACKGROUND: Stereotactic arrhythmia radiotherapy (STAR) has been proposed recently in patients with refractory ventricular tachycardia (VT). OBJECTIVES: The purpose of this study was to describe the efficacy and safety of STAR in the Czech Republic. METHODS: VT patients were recruited in 2 expert centers after at least 1 previously failed catheter ablation (CA). A precise strategy of target volume determination and CA was used in 17 patients treated from December 2018 until June 2022 (EFFICACY cohort). This group, together with an earlier series of 19 patients with less-defined treatment strategies, composed the SAFETY cohort (n = 36). A dose of 25 Gy was delivered. RESULTS: In the EFFICACY cohort, the burden of implantable cardioverter-defibrillator therapies decreased, and this drop reached significance for direct current shocks (1.9 ± 3.2 vs 0.1 ± 0.2 per month; P = 0.03). Eight patients (47%) underwent repeated CA for recurrences of VT during 13.7 ± 11.6 months. In the SAFETY cohort (32 procedures, follow-up >6 months), 8 patients (25%) presented with a progression of mitral valve regurgitation, and 3 (9%) required intervention (median follow-up of 33.5 months). Two cases of esophagitis (6%) were seen with 1 death caused by the esophago-pericardial fistula (3%). A total of 18 patients (50%) died during the median follow-up of 26.9 months. CONCLUSIONS: Although STAR may not be very effective in preventing VT recurrences after failed CA in an expert center, it can still modify the arrhythmogenic substrate, and when used with additional CA, reduce the number of implantable cardioverter-defibrillator shocks. Potentially serious sides effects require close follow-up.


Assuntos
Radiocirurgia , Taquicardia Ventricular , Humanos , Masculino , Taquicardia Ventricular/cirurgia , Feminino , Pessoa de Meia-Idade , República Tcheca , Idoso , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Recidiva , Desfibriladores Implantáveis , Ablação por Cateter/efeitos adversos , Resultado do Tratamento
12.
JACC Clin Electrophysiol ; 10(4): 750-758, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38363278

RESUMO

BACKGROUND: Ventricular tachycardia (VT) and ventricular fibrillation (VF) are life-threatening conditions and can be refractory to conventional drug and device interventions. Stellate ganglion blockade (SGB) has been described as an adjunct, temporizing intervention in patients with refractory ventricular arrhythmia. We examined the association of SGB with VT/VF in a multicenter registry. OBJECTIVES: This study examined the efficacy of SGB for treatment/temporization of refractory VT/VF. METHODS: The authors present the first analysis from a multicenter registry of patients treated for refractory ventricular arrhythmia at a clinical site in the Czech Republic and the United States. Data were collected between 2016 and 2022. SGB was performed at the bedside by anesthesiologists and/or cardiologists. Outcomes of interest were VT/VF burden and defibrillations at 24 hours before and after SGB. RESULTS: In total, there were 117 patients with refractory ventricular arrhythmias treated with SGB at Duke (n = 49) and the Institute for Clinical and Experimental Medicine (n = 68). The majority of patients were male (94.0%), were White (87.2%), and had an implantable cardioverter-defibrillator (70.1%). The most common etiology of heart disease was ischemic cardiomyopathy (52.1%), and monomorphic VT was the most common morphology (70.1%). Within 24 hours before SGB (0-24 hours), the median episodes of VT/VF were 7.5 (Q1-Q3: 3.0-27.0), and 24 hours after SGB, the median decreased to 1.0 (Q1-Q3: 0.0-4.5; P < 0.001). At 24 hours before SGB, the median defibrillation events were 2.0 (Q1-Q3: 0.0-8.0), and 24 hours after SGB, the median decreased to 0.0 (Q1-Q3: 0.0-1.0; P < 0.001). CONCLUSIONS: In the largest cohort of patients with treatment-refractory ventricular arrhythmia, we demonstrate that SGB use was associated with a reduction in the ventricular arrhythmia burden and need for defibrillation therapy.


Assuntos
Bloqueio Nervoso Autônomo , Gânglio Estrelado , Taquicardia Ventricular , Fibrilação Ventricular , Humanos , Masculino , Feminino , Taquicardia Ventricular/terapia , Pessoa de Meia-Idade , Idoso , Fibrilação Ventricular/terapia , Bloqueio Nervoso Autônomo/métodos , Sistema de Registros , Desfibriladores Implantáveis , República Tcheca , Resultado do Tratamento , Estados Unidos , Adulto
13.
Mol Biol Rep ; 51(1): 164, 2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38252350

RESUMO

BACKGROUND: Despite a general decline in mean levels across populations, LDL-cholesterol levels remain a major risk factor for acute coronary syndrome (ACS). The APOB, LDL-R, CILP, and SORT-1 genes have been shown to contain variants that have significant effects on plasma cholesterol levels. METHODS AND RESULTS: We examined polymorphisms within these genes in 1191 controls and 929 patients with ACS. Only rs646776 within SORT-1 was significantly associated with a risk of ACS (P < 0.05, AA vs. + G comparison; OR 1.21; 95% CI 1.01-1.45). With regard to genetic risk score (GRS), the presence of at least 7 alleles associated with elevated cholesterol levels was connected with increased risk (P < 0.01) of ACS (OR 1.26; 95% CI 1.06-1.52). Neither total mortality nor CVD mortality in ACS subjects (follow up-9.84 ± 3.82 years) was associated with the SNPs analysed or cholesterol-associated GRS. CONCLUSIONS: We conclude that, based on only a few potent SNPs known to affect plasma cholesterol, GRS has the potential to predict ACS risk, but not ACS associated mortality.


Assuntos
Síndrome Coronariana Aguda , Estratificação de Risco Genético , Masculino , Humanos , Síndrome Coronariana Aguda/genética , República Tcheca/epidemiologia , Colesterol , Polimorfismo de Nucleotídeo Único/genética
14.
Artigo em Inglês | MEDLINE | ID: mdl-38191005

RESUMO

Patients treated with cardiac stereotactic body radiation therapy (radioablation) for refractory ventricular arrhythmias are patients with advanced structural heart disease and significant comorbidities. However, data regarding 1-year mortality after the procedure are scarce. This systematic review and pooled analysis aimed at determining 1-year mortality after cardiac radioablation for refractory ventricular arrhythmias and investigating leading causes of death in this population. MEDLINE/EMBASE databases were searched up to January 2023 for studies including patients undergoing cardiac radioablation for the treatment of refractory ventricular arrhythmias. Quality of included trials was assessed using the NIH Tool for Case Series Studies (PROSPERO CRD42022379713). A total of 1,151 references were retrieved and evaluated for relevance. Data were extracted from 16 studies, with a total of 157 patients undergoing cardiac radioablation for refractory ventricular arrhythmias. Pooled 1-year mortality was 32 % (95 %CI: 23-41), with almost half of the deaths occurring within three months after treatment. Among the 157 patients, 46 died within the year following cardiac radioablation. Worsening heart failure appeared to be the leading cause of death (52 %), although non-cardiac mortality remained substantial (41 %) in this population. Age≥70yo was associated with a significantly higher 12-month all-cause mortality (p<0.022). Neither target volume size nor radiotherapy device appeared to be associated with 1-year mortality (p = 0.465 and p = 0.199, respectively). About one-third of patients undergoing cardiac stereotactic body radiation therapy for refractory ventricular arrhythmias die within the first year after the procedure. Worsening heart failure appears to be the leading cause of death in this population.

15.
ESC Heart Fail ; 11(2): 1097-1109, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38263857

RESUMO

AIMS: The determinants and relevance of right ventricular (RV) mechanical dyssynchrony in heart failure with reduced ejection fraction (HFrEF) are poorly understood. We hypothesized that increased afterload may adversely affect the synchrony of RV contraction. METHODS AND RESULTS: A total of 148 patients with HFrEF and 36 controls underwent echocardiography, right heart catheterization, and gated single-photon emission computed tomography to measure RV chamber volumes and mechanical dyssynchrony (phase standard deviation of systolic displacement timing). Exams were repeated after preload (N = 135) and afterload (N = 15) modulation. Patients with HFrEF showed higher RV dyssynchrony compared with controls (40.6 ± 17.5° vs. 27.8 ± 9.1°, P < 0.001). The magnitude of RV dyssynchrony in HFrEF correlated with larger RV and left ventricular (LV) volumes, lower RV ejection fraction (RVEF) and LV ejection fraction, reduced intrinsic contractility, increased heart rate, higher pulmonary artery (PA) load, and impaired RV-PA coupling (all P ≤ 0.01). Low RVEF was the strongest predictor of RV dyssynchrony. Left bundle branch block (BBB) was associated with greater RV dyssynchrony than right BBB, regardless of QRS duration. RV afterload reduction by sildenafil improved RV dyssynchrony (P = 0.004), whereas preload change with passive leg raise had modest effect. Patients in the highest tertiles of RV dyssynchrony had an increased risk of adverse clinical events compared with those in the lower tertile [T2/T3 vs. T1: hazard ratio 1.98 (95% confidence interval 1.20-3.24), P = 0.007]. CONCLUSIONS: RV dyssynchrony is associated with RV remodelling, dysfunction, adverse haemodynamics, and greater risk for adverse clinical events. RV dyssynchrony is mitigated by acute RV afterload reduction and could be a potential therapeutic target to improve RV performance in HFrEF.


Assuntos
Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Volume Sistólico , Ventrículos do Coração/diagnóstico por imagem , Ecocardiografia/métodos , Função Ventricular Esquerda
16.
J Am Heart Assoc ; 13(2): e032505, 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38193321

RESUMO

BACKGROUND: Heart failure is a common complication after myocardial infarction (MI) and is associated with increased mortality. Whether remote heart failure symptoms assessment after MI can improve risk stratification is unknown. The authors evaluated the association of the 23-item Kansas City Cardiomyopathy Questionnaire (KCCQ) with all-cause mortality after MI. METHODS AND RESULTS: Prospectively collected data from consecutive patients hospitalized for MI at a large tertiary heart center between June 2017 and September 2022 were used. Patients remotely completed the KCCQ 1 month after discharge. A total of 1135 (aged 64±12 years, 26.7% women) of 1721 eligible patients completed the KCCQ. Ranges of KCCQ scores revealed that 30 (2.6%), 114 (10.0%), 274 (24.1%), and 717 (63.2%) had scores <25, 25 to 49, 50 to 74, and ≥75, respectively. During a mean follow-up of 46 months (interquartile range, 29-61), 146 (12.9%) died. In a fully adjusted analysis, KCCQ scores <50 were independently associated with mortality (hazard ratio [HR], 6.05 for KCCQ <25, HR, 2.66 for KCCQ 25-49 versus KCCQ ≥50; both P<0.001). Adding the 30-day KCCQ to clinical risk factors improved risk stratification: change in area under the curve of 2.6 (95% CI, 0.3-5.0), Brier score of -0.6 (95% CI, -1.0 to -0.2), and net reclassification improvement of 0.71 (95% CI, 0.45-1.04). KCCQ items most strongly associated with mortality were walking impairment, leg swelling, and change in symptoms. CONCLUSIONS: Remote evaluation of heart failure symptoms using the KCCQ among patients recently discharged for MI identifies patients at risk for mortality. Whether closer follow-up and targeted therapy can reduce mortality in high-risk patients warrants further study.


Assuntos
Insuficiência Cardíaca , Infarto do Miocárdio , Humanos , Feminino , Masculino , Hospitalização , Insuficiência Cardíaca/terapia , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico , Alta do Paciente , Modelos de Riscos Proporcionais , Qualidade de Vida , Nível de Saúde
17.
N Engl J Med ; 390(2): 107-117, 2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-37952132

RESUMO

BACKGROUND: Subclinical atrial fibrillation is short-lasting and asymptomatic and can usually be detected only by long-term continuous monitoring with pacemakers or defibrillators. Subclinical atrial fibrillation is associated with an increased risk of stroke by a factor of 2.5; however, treatment with oral anticoagulation is of uncertain benefit. METHODS: We conducted a trial involving patients with subclinical atrial fibrillation lasting 6 minutes to 24 hours. Patients were randomly assigned in a double-blind, double-dummy design to receive apixaban at a dose of 5 mg twice daily (2.5 mg twice daily when indicated) or aspirin at a dose of 81 mg daily. The trial medication was discontinued and anticoagulation started if subclinical atrial fibrillation lasting more than 24 hours or clinical atrial fibrillation developed. The primary efficacy outcome, stroke or systemic embolism, was assessed in the intention-to-treat population (all the patients who had undergone randomization); the primary safety outcome, major bleeding, was assessed in the on-treatment population (all the patients who had undergone randomization and received at least one dose of the assigned trial drug, with follow-up censored 5 days after permanent discontinuation of trial medication for any reason). RESULTS: We included 4012 patients with a mean (±SD) age of 76.8±7.6 years and a mean CHA2DS2-VASc score of 3.9±1.1 (scores range from 0 to 9, with higher scores indicating a higher risk of stroke); 36.1% of the patients were women. After a mean follow-up of 3.5±1.8 years, stroke or systemic embolism occurred in 55 patients in the apixaban group (0.78% per patient-year) and in 86 patients in the aspirin group (1.24% per patient-year) (hazard ratio, 0.63; 95% confidence interval [CI], 0.45 to 0.88; P = 0.007). In the on-treatment population, the rate of major bleeding was 1.71% per patient-year in the apixaban group and 0.94% per patient-year in the aspirin group (hazard ratio, 1.80; 95% CI, 1.26 to 2.57; P = 0.001). Fatal bleeding occurred in 5 patients in the apixaban group and 8 patients in the aspirin group. CONCLUSIONS: Among patients with subclinical atrial fibrillation, apixaban resulted in a lower risk of stroke or systemic embolism than aspirin but a higher risk of major bleeding. (Funded by the Canadian Institutes of Health Research and others; ARTESIA ClinicalTrials.gov number, NCT01938248.).


Assuntos
Anticoagulantes , Aspirina , Fibrilação Atrial , Embolia , Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Anticoagulantes/efeitos adversos , Anticoagulantes/uso terapêutico , Aspirina/efeitos adversos , Aspirina/uso terapêutico , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Canadá , Embolia/etiologia , Embolia/prevenção & controle , Hemorragia/induzido quimicamente , Piridonas/efeitos adversos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento , Inibidores do Fator Xa/efeitos adversos , Inibidores do Fator Xa/uso terapêutico , Método Duplo-Cego
19.
Front Cardiovasc Med ; 10: 1248145, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38144370

RESUMO

Background and aims: Analysis of mortality from the national health registries and data from a specific central registry dealing with the implantation of pacemakers (REPACE) in Czech patients. Methods and results: Retrospective observational analysis of pacemakers' implantation in all Czech patients [n = 82,791; 47,070 (56.9%) men, 75.9 ± 10.4 years old] between 2010 and 2021. Almost 114,000 pacemakers were implanted between 2010 and 2021, of which 27.9% were single-chamber, 67.4% were dual-chamber and 4.6% were biventricular. The annual number of implantations has been steadily increasing with a 6% annual decline in 2020 with increased mortality and reductions in care provided, likely related to COVID-19. The observed 5-year relative survival was 88.6% (overall survival 60.6%) and the 10-year relative survival was 75.9% (overall survival 32.7%). Causes of death 5ary according to the age of the patient. The highest difference 1n the reported numbers in the REPACE Registry did not exceed 2% in comparison with the National Register of Reimbursed Health Services. Conclusion: This study followed all Czech patients with pacemaker's implantation in between 2010 and 2021. The annual number of 1mplantations has been steadily 1ncreasing. Patients with implanted pacemakers had a significantly higher mortality than the average population. Number of patients in the registry corresponded almost perfectly with the National Register of Reimbursed Health Services.

20.
Eur Cardiol ; 18: e59, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38023337

RESUMO

Aims: The interpretation of intracardiac electrograms recorded from conventional electrophysiology recording systems is frequently impacted by powerline (50/60 Hz) noise and distortion due to notch filtering. This study compares unipolar electrograms recorded simultaneously from a conventional electrophysiology recording system and one of two 3D mapping systems (control system) with those from a novel system (ECGenius, CathVision ApS) designed to reduce noise without the need for conventional filtering. Methods: Unipolar electrograms were recorded simultaneously from nine consecutive patients undergoing catheter ablation for AF (five patients), atrioventricular nodal re-entrant tachycardia (three patients), or ventricular tachycardia (one patient) over the course of 1 week in 2020. Results: The noise spectral power of the novel system (49-51 Hz) was 6.1 ± 6.2 times lower than that of the control system. Saturation artefact following pacing (duration 97 ± 85 ms) occurred in eight control recordings and no novel system recordings (p<0.001). High frequency, low amplitude signals and fractionated electrograms apparent on unfiltered novel system unipolar recordings were not present on control recordings. Control system notch filtering obscured His bundle electrograms observable without such filtering using the novel system and induced electrogram distortion that was not present on novel system recordings. Signal saturation occurred in five of seven control system recordings but none of the novel system recordings. Conclusion: In this study, novel system recordings exhibited less noise and fewer signal artefacts than the conventional control system and did not require notch filtering that distorted electrograms on control recordings. The novel recording system provided superior electrogram data not apparent with conventional systems.