Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Europace ; 2024 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-38702961

RESUMO

BACKGROUND AND AIMS: Clinical concerns exist about the potential proarrhythmic effects of the sodium channel blockers flecainide and propafenone (SCB) in patients with cardiovascular disease. SCB were used to deliver early rhythm control (ERC) therapy in EAST-AFNET 4. METHODS: We analysed the primary safety outcome (death, stroke, or serious adverse events related to rhythm-control therapy) and primary efficacy outcome (cardiovascular death, stroke and hospitalization for worsening of heart failure or acute coronary syndrome) during SCB-intake for ERC patients (n = 1395) in EAST-AFNET 4. The protocol discouraged flecainide and propafenone in patients with reduced left ventricular ejection fraction and suggested stopping therapy upon QRS prolongation >25% on therapy. RESULTS: Flecainide or propafenone was given to 689 patients (age 69 (8) years; CHA2DS2-VASc 3.2 (1); 177 with heart failure; 41 with prior myocardial infarction, CABG or PCI; 26 with left ventricular hypertrophy >15 mm; median therapy duration 1,153 [237, 1,828] days). The primary efficacy outcome occurred less often in patients treated with SCB (3/100 (99/3,316) patient-years) than in patients who never received SCB (SCBnever 4.9/100 (150/3,083) patient-years, p < 0.001). There were numerically fewer primary safety outcomes in patients receiving SCB (2.9/100 (96/3,359) patient-years) than in SCBnever patients (4.2/100 (135/3,220) patient-years, adjusted p = 0.015). Sinus rhythm at 2 years was similar between groups (SCB 537/610 (88); SCBnever 472/579 (82)). CONCLUSION: Long-term therapy with flecainide or propafenone appeared to be safe in the EAST-AFNET 4 trial to deliver effective ERC therapy, including in selected patients with stable cardiovascular disease such as coronary artery disease and stable heart failure. CLINICAL TRIAL REGISTRATION: ISRCTN04708680, NCT01288352, EudraCT2010-021258-20, www.easttrial.org.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38430087

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) alone is insufficient to treat many patients with persistent atrial fibrillation (PersAF). Adjunctive left atrial posterior wall (LAPW) ablation with thermal technologies has revealed lack of efficacy, perhaps limited by the difficulty in achieving lesion durability amid concerns of esophageal injury. OBJECTIVES: This study aims to compare the safety and effectiveness of PVI + LAPW ablation vs PVI in patients with PersAF using pulsed-field ablation (PFA). METHODS: In a retrospective analysis of the MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-approval Clinical Use of Pulsed Field Ablation) registry, we studied consecutive PersAF patients undergoing post-approval treatment with a pentaspline PFA catheter. The primary effectiveness outcome was freedom from any atrial arrhythmia of ≥30 seconds. Safety outcomes included the composite of acute and chronic major adverse events. RESULTS: Of the 547 patients with PersAF who underwent PFA, 131 (24%) received adjunctive LAPW ablation. Compared to PVI-alone, patients receiving adjunctive LAPW ablation were younger (65 vs 67 years of age, P = 0.08), had a lower CHA2DS2-VASc score (2.3 ± 1.6 vs 2.6 ± 1.6, P = 0.08), and were more likely to receive electroanatomical mapping (48.1% vs 39.0%, P = 0.07) and intracardiac echocardiography imaging (46.1% vs 17.1%, P < 0.001). The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmias was not statistically different between groups in the full (PVI + LAPW: 66.4%; 95% CI: 57.6%-74.4% vs PVI: 73.1%; 95% CI: 68.5%-77.2%; P = 0.68) and propensity-matched cohorts (PVI + LAPW: 71.7% vs PVI: 68.5%; P = 0.34). There was also no significant difference in major adverse events between the groups (2.2% vs 1.4%, respectively, P = 0.51). CONCLUSIONS: In patients with PersAF undergoing PFA, as compared to PVI-alone, adjunctive LAPW ablation did not improve freedom from atrial arrhythmia at 12 months.

5.
Heart Rhythm ; 21(3): 250-257, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38036235

RESUMO

BACKGROUND: Pulsed-field ablation (PFA) is a nonthermal energy source for ablation of cardiac arrhythmias. This study investigated the prospective outcomes of a novel PFA generator in conjunction with a commercially available, contact force-sensing, focal ablation catheter. OBJECTIVE: The purpose of this study was to assess the feasibility, safety, and lesion characteristics of point-by-point PFA in consecutive patients undergoing repeat ablation of atrial fibrillation (AF). METHODS: The study involved reisolation of pulmonary veins (PVs) with electrical reconnection and the creation of an anterior line (AL) in patients with anterior substrate or durable pulmonary vein isolation (PVI). RESULTS: In 24 patients (46% female; mean age 67 ± 10 years; 67% persistent AF), successful reisolation of 27 of 27 reconnected PVs (100%) was performed. In 19 patients, AL ablation was performed, with bidirectional block in 16 (84%), median ablation time 26 [21, 33] minutes, and first-pass bidirectional block in 13 patients (68%). Acute AL reconduction occurred in 8 of 19 patients (42%). Among these 8 patients, a subsequent sustained block of the AL was achieved in 5 (63%). Ultra-high-density electroanatomic mapping revealed homogeneous but relatively large low-voltage areas in the ablated regions. Median procedural, left atrial dwell, and fluoroscopy times were 100 [90, 109] minutes, 83 [75, 98] minutes, and 10 [8, 13] minutes, respectively. No major or minor complications occurred. CONCLUSION: This study demonstrated feasibility, acute efficacy, and safety of point-by-point PFA for repeat PVI and AL ablation. Further studies are warranted to assess the long-term durability and comparison with established ablation methods.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Veias Pulmonares/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Fibrilação Atrial/cirurgia , Átrios do Coração , Ablação por Cateter/métodos , Recidiva
6.
JAMA Cardiol ; 8(12): 1142-1151, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37910101

RESUMO

Importance: Previous studies evaluating the association of patient sex with clinical outcomes using conventional thermal ablative modalities for atrial fibrillation (AF) such as radiofrequency or cryoablation are controversial due to mixed results. Pulsed field ablation (PFA) is a novel AF ablation energy modality that has demonstrated preferential myocardial tissue ablation with a unique safety profile. Objective: To compare sex differences in patients undergoing PFA for AF in the Multinational Survey on the Methods, Efficacy, and Safety on the Postapproval Clinical Use of Pulsed Field Ablation (MANIFEST-PF) registry. Design, Setting, and Participants: This was a retrospective cohort study of MANIFEST-PF registry data, which included consecutive patients undergoing postregulatory approval treatment with PFA to treat AF between March 2021 and May 2022 with a median follow-up of 1 year. MANIFEST-PF is a multinational, retrospectively analyzed, prospectively enrolled patient-level registry including 24 European centers. The study included all consecutive registry patients (age ≥18 years) who underwent first-ever PFA for paroxysmal or persistent AF. Exposure: PFA was performed on patients with AF. All patients underwent pulmonary vein isolation and additional ablation, which was performed at the discretion of the operator. Main Outcomes and Measures: The primary effectiveness outcome was freedom from clinically documented atrial arrhythmia for 30 seconds or longer after a 3-month blanking period. The primary safety outcome was the composite of acute (<7 days postprocedure) and chronic (>7 days) major adverse events (MAEs). Results: Of 1568 patients (mean [SD] age, 64.5 [11.5] years; 1015 male [64.7%]) with AF who underwent PFA, female patients, as compared with male patients, were older (mean [SD] age, 68 [10] years vs 62 [12] years; P < .001), had more paroxysmal AF (70.2% [388 of 553] vs 62.4% [633 of 1015]; P = .002) but had fewer comorbidities such as coronary disease (9% [38 of 553] vs 15.9% [129 of 1015]; P < .001), heart failure (10.5% [58 of 553] vs 16.6% [168 of 1015]; P = .001), and sleep apnea (4.7% [18 of 553] vs 11.7% [84 of 1015]; P < .001). Pulmonary vein isolation was performed in 99.8% of female (552 of 553) and 98.9% of male (1004 of 1015; P = .90) patients. Additional ablation was performed in 22.4% of female (124 of 553) and 23.1% of male (235 of 1015; P = .79) patients. The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was similar in male and female patients (79.0%; 95% CI, 76.3%-81.5% vs 76.3%; 95% CI, 72.5%-79.8%; P = .28). There was also no significant difference in acute major AEs between groups (male, 1.5% [16 of 1015] vs female, 2.5% [14 of 553]; P = .19). Conclusion and Relevance: Results of this cohort study suggest that after PFA for AF, there were no significant sex differences in clinical effectiveness or safety events.


Assuntos
Fibrilação Atrial , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Adolescente , Fibrilação Atrial/tratamento farmacológico , Estudos Retrospectivos , Estudos de Coortes , Fatores Sexuais , Resultado do Tratamento
8.
J Cardiovasc Electrophysiol ; 34(9): 1802-1807, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37473404

RESUMO

INTRODUCTION: Pulsed-field ablation (PFA) and the multielectrode radiofrequency balloon (RFB) are two novel ablation technologies to perform pulmonary vein isolation (PVI). It is currently unknown whether these technologies differ in lesion formation and lesion extent. We compared the acute lesion extent after PVI induced by PFA and RFB by measuring low-voltage area in high-density maps and the release of biomolecules reflecting cardiac injury. METHODS: PVI was performed with a pentaspline catheter (FARAPULSE) applying PFA or with the compliant multielectrode RFB (HELIOSTAR). Before and after PVI high-density mapping with CARTO 3 was performed. In addition, blood samples were taken before transseptal puncture and after post-PVI remapping and serum concentrations of high-sensitive Troponin I were quantified by immunoassay. RESULTS: Sixty patients undergoing PVI by PFA (n = 28, age 69 ± 12 year, 60% males, 39.3% persistent atrial fibrillation [AF]) or RFB (n = 32, age 65 ± 13 year, 53% males, 21.9% persistent AF) were evaluated. Acute PVI was achieved in all patients in both groups. Mean number of PFA pulses was 34.2 ± 4.5 and mean number RFB applications was 8.5 ± 3 per patient. Total posterior ablation area was significantly larger in PFA (20.7 ± 7.7 cm²) than in RFB (7.1 ± 2.09 cm²; p < .001). Accordingly, posterior ablation area for each PV resulted in larger lesions after PFA versus RFB (LSPV 5.2 ± 2.7 vs. 1.9 ± 0.8 cm², LIPV 5.5 ± 2.3 vs. 1.9 ± 0.8 cm², RSPV 4.7 ± 1.9 vs. 1.6 ± 0.5 cm², RIPV 5.3 ± 2.1 vs. 1.6 ± 0.7 cm,² respectively; p < .001). In a subset of 38 patients, increase of hsTropI was higher after PFA (625 ± 138 pg/mL, n = 28) versus RFB (148 ± 36 pg/mL, n = 10; p = .049) supporting the evidence of larger lesion extent by PFA. CONCLUSION: PFA delivers larger acute lesion areas and higher troponin release upon successful PVI than multielectrode RFB-based PVI in this single-center series.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Veias Pulmonares/cirurgia , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Catéteres
9.
Circulation ; 148(1): 35-46, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37199171

RESUMO

BACKGROUND: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (<7 days postprocedure) and latent (>7 days) major adverse events. RESULTS: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA2DS2-VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289-421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%-80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P=0.001). Acute major adverse events occurred in 1.9% of patients. CONCLUSIONS: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Flutter Atrial/etiologia , Sistema de Registros , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
11.
Circ Arrhythm Electrophysiol ; 16(3): e011602, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36763906

RESUMO

BACKGROUND: Electrical remodeling in human persistent atrial fibrillation is believed to result from rapid electrical activation of the atria, but underlying genetic causes may contribute. Indeed, common gene variants in an enhancer region close to PITX2 (paired-like homeodomain transcription factor 2) are strongly associated with atrial fibrillation, but the mechanism behind this association remains unknown. This study evaluated the consequences of PITX2 deletion (PITX2-/-) in human induced pluripotent stem cell-derived atrial cardiomyocytes. METHODS: CRISPR/Cas9 (clustered regularly interspaced short palindromic repeats/clustered regularly interspaced short palindromic repeat-associated 9) was used to delete PITX2 in a healthy human iPSC line that served as isogenic control. Human induced pluripotent stem cell-derived atrial cardiomyocytes were differentiated with unfiltered retinoic acid and cultured in atrial engineered heart tissue. Force and action potential were measured in atrial engineered heart tissues. Single human induced pluripotent stem cell-derived atrial cardiomyocytes were isolated from atrial engineered heart tissue for ion current measurements. RESULTS: PITX2-/- atrial engineered heart tissue beats slightly slower than isogenic control without irregularity. Force was lower in PITX2-/- than in isogenic control (0.053±0.015 versus 0.131±0.017 mN, n=28/3 versus n=28/4, PITX2-/- versus isogenic control; P<0.0001), accompanied by lower expression of CACNA1C and lower L-type Ca2+ current density. Early repolarization was weaker (action potential duration at 20% repolarization; 45.5±13.2 versus 8.6±5.3 ms, n=18/3 versus n=12/4, PITX2-/- versus isogenic control; P<0.0001), and maximum diastolic potential was more negative (-78.3±3.1 versus -69.7±0.6 mV, n=18/3 versus n=12/4, PITX2-/- versus isogenic control; P=0.001), despite normal inward rectifier currents (both IK1 and IK,ACh) and carbachol-induced shortening of action potential duration. CONCLUSIONS: Complete PITX2 deficiency in human induced pluripotent stem cell-derived atrial cardiomyocytes recapitulates some findings of electrical remodeling of atrial fibrillation in the absence of fast beating, indicating that these abnormalities could be primary consequences of lower PITX2 levels.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Células-Tronco Pluripotentes Induzidas , Humanos , Células-Tronco Pluripotentes Induzidas/metabolismo , Átrios do Coração , Potenciais de Ação , Miócitos Cardíacos/metabolismo
12.
Europace ; 25(2): 688-697, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-35989424

RESUMO

AIMS: Cardiac arrhythmia originating from the papillary muscle (PM) can trigger ventricular fibrillation (VF) and cause sudden cardiac death even in the absence of structural heart disease. Most premature ventricular contractions, however, are benign and hitherto difficult to distinguish from a potentially fatal arrhythmia. Altered repolarization characteristics are associated with electrical instability, but electrophysiological changes which precede degeneration into VF are still not fully understood. METHODS AND RESULTS: Ventricular arrhythmia (VA) was induced by aconitine injection into PMs of healthy sheep. To investigate mechanisms of degeneration of stable VA into VF in structurally healthy hearts, endocardial high-density and epicardial mapping was performed during sinus rhythm (SR) and VA. The electrical restitution curve, modelling the relation of diastolic interval and activation recovery interval (a surrogate parameter for action potential duration), is steeper in VA than in non-arrhythmia (ventricular pacing and SR). Steeper restitution curves reflect electrical instability and propensity to degenerate into VF. Importantly, we find the parameter repolarization time in relation to cycle length (RT/CL) to differentiate self-limiting from degenerating arrhythmia with high specificity and sensitivity. CONCLUSION: RT/CL may serve as a simple index to aid differentiation between self-limiting and electrically instable arrhythmia with the propensity to degenerate to VF. RT/CL is independent of cycle length and could easily be measured to identify electrical instability in patients.


Assuntos
Arritmias Cardíacas , Músculos Papilares , Animais , Ovinos , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/etiologia , Ventrículos do Coração , Potenciais de Ação/fisiologia , Eletrocardiografia
13.
Clin Res Cardiol ; 112(6): 795-806, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36131138

RESUMO

PURPOSE: Pulsed-field ablation (PFA) is a new energy source to achieve pulmonary vein isolation (PVI) by targeted electroporation of cardiomyocytes. Experimental and controlled clinical trial data suggest good efficacy of PFA-based PVI. We aimed to assess efficacy, safety and follow-up of PFA-based PVI in an early adopter routine care setting. METHODS: Consecutive patients with symptomatic paroxysmal or persistent atrial fibrillation (AF) underwent PVI using the Farawave® PFA ablation catheter in conjunction with three-dimensional mapping at two German high-volume ablation centers. PVI was achieved by applying 8 PFA applications in each PV. RESULTS: A total of 138 patients undergoing a first PVI (67 ± 12 years, 66% male, 62% persistent AF) were treated. PVI was achieved in all patients by deploying 4563 applications in 546 PVs (8.4 ± 1.0/PV). Disappearance of PV signals after the first application was demonstrated in 544/546 PVs (99.6%). More than eight PFA applications were performed in 29/546 PVs (6%) following adapted catheter positioning or due to reconnection as assessed during remapping. Mean procedure time was 78 ± 22 min including pre- and post PVI high-density voltage mapping. PFA catheter LA dwell-time was 23 ± 9 min. Total fluoroscopy time and dose area product were 16 ± 7 min and 505 [275;747] cGy*cm2. One pericardial tamponade (0.7%), one transient ST-elevation (0.7%) and three groin complications (2.2%) occurred. 1-year follow-up showed freedom of arrhythmia in 90% in patients with paroxysmal AF (n = 47) and 60% in patients with persistent AF (n = 82, p = 0.015). CONCLUSIONS: PFA-based PVI is acutely highly effective and associated with a beneficial safety and low recurrence rate.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Feminino , Seguimentos , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fluoroscopia , Resultado do Tratamento , Recidiva
14.
Cells ; 11(17)2022 09 02.
Artigo em Inglês | MEDLINE | ID: mdl-36078153

RESUMO

Genetic variants in α-actinin-2 (ACTN2) are associated with several forms of (cardio)myopathy. We previously reported a heterozygous missense (c.740C>T) ACTN2 gene variant, associated with hypertrophic cardiomyopathy, and characterized by an electro-mechanical phenotype in human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs). Here, we created with CRISPR/Cas9 genetic tools two heterozygous functional knock-out hiPSC lines with a second wild-type (ACTN2wt) and missense ACTN2 (ACTN2mut) allele, respectively. We evaluated their impact on cardiomyocyte structure and function, using a combination of different technologies, including immunofluorescence and live cell imaging, RNA-seq, and mass spectrometry. This study showed that ACTN2mut presents a higher percentage of multinucleation, protein aggregation, hypertrophy, myofibrillar disarray, and activation of both the ubiquitin-proteasome system and the autophagy-lysosomal pathway as compared to ACTN2wt in 2D-cultured hiPSC-CMs. Furthermore, the expression of ACTN2mut was associated with a marked reduction of sarcomere-associated protein levels in 2D-cultured hiPSC-CMs and force impairment in engineered heart tissues. In conclusion, our study highlights the activation of proteolytic systems in ACTN2mut hiPSC-CMs likely to cope with ACTN2 aggregation and therefore directs towards proteopathy as an additional cellular pathology caused by this ACTN2 variant, which may contribute to human ACTN2-associated cardiomyopathies.


Assuntos
Actinina , Cardiomiopatia Hipertrófica , Agregação Patológica de Proteínas , Actinina/genética , Actinina/metabolismo , Cardiomiopatia Hipertrófica/genética , Cardiomiopatia Hipertrófica/metabolismo , Humanos , Células-Tronco Pluripotentes Induzidas/metabolismo , Miócitos Cardíacos/metabolismo , Agregação Patológica de Proteínas/genética , Agregação Patológica de Proteínas/metabolismo , Sarcômeros/metabolismo
16.
Cells ; 11(15)2022 08 05.
Artigo em Inglês | MEDLINE | ID: mdl-35954268

RESUMO

The physiological importance of NCX in human-induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) is not well characterized but may depend on the relative strength of the current, compared to adult cardiomyocytes, and on the exact spatial arrangement of proteins involved in Ca2+ extrusion. Here, we determined NCX currents and its contribution to action potential and force in hiPSC-CMs cultured in engineered heart tissue (EHT). The results were compared with data from rat and human left ventricular tissue. The NCX currents in hiPSC-CMs were larger than in ventricular cardiomyocytes isolated from human left ventricles (1.3 ± 0.2 pA/pF and 3.2 ± 0.2 pA/pF for human ventricle and EHT, respectively, p < 0.05). SEA0400 (10 µM) markedly shortened the APD90 in EHT (by 26.6 ± 5%, p < 0.05) and, to a lesser extent, in rat ventricular tissue (by 10.7 ± 1.6%, p < 0.05). Shortening in human left ventricular preparations was small and not different from time-matched controls (TMCs; p > 0.05). Force was increased by the NCX block in rat ventricle (by 31 ± 5.4%, p < 0.05) and EHT (by 20.8 ± 3.9%, p < 0.05), but not in human left ventricular preparations. In conclusion, hiPSC-CMs possess NCX currents not smaller than human left ventricular tissue. Robust NCX block-induced APD shortening and inotropy makes EHT an attractive pharmacological model.


Assuntos
Células-Tronco Pluripotentes Induzidas , Potenciais de Ação , Adulto , Animais , Ventrículos do Coração/metabolismo , Humanos , Células-Tronco Pluripotentes Induzidas/metabolismo , Miócitos Cardíacos/metabolismo , Ratos , Trocador de Sódio e Cálcio/metabolismo
17.
Front Cardiovasc Med ; 9: 910042, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35694678

RESUMO

Introduction: Catheter ablation of ventricular arrhythmias emerging from the ventricular outflow tracts and adjacent structures is very effective and considered almost curative in patients without structural heart disease (SHD). Outcomes of patients with SHD undergoing ablation of outflow tract arrhythmias are not known. Methods: Consecutive patients (2019-2021) undergoing catheter ablation of ventricular arrhythmias in a single high-volume center were retrospectively analyzed. Patients with ablation of outflow tract arrhythmias were identified and divided in individuals with and without SHD. Procedural parameters and acute outcome were compared. Results: We identified 215 patients with outflow tract arrhythmias (35.3% female, mean age 58.3 ± 16.0 years). Of those, 93 (43.3%) had SHD. Patients with SHD and outflow tract arrhythmias were older (65.0 ± 12.8 vs. 53.3 ± 16.3 years; p < 0.001), more often male (82.8 vs. 50.0%; p < 0.001) and had more comorbidities than patients without SHD (arterial hypertension: 62.4 vs. 34.4%, p < 0.001; diabetes: 22.6 vs. 8.2%, p = 0.005; chronic lung disease: 20.4 vs. 7.4%, p = 0.007). Outflow tract arrhythmias in patients with SHD had their origin more often in the left ventricle (68.8 vs. 53.3%, p = 0.025). The acute success rate was similar in both patient groups (93.4 vs. 94.2%, p = 0.781). Patients with SHD were discharged later {median length of hospital stay with SHD 5 [6 (interquartile range)] days, without SHD 2 [4] days, p < 0.001}. Periprocedural complications were numerically more frequent in patients with SHD [with SHD 12 (12.9%), without SHD 8 (6.6%), p = 0.154]. Conclusion: Outflow tract arrhythmia ablation has a high success rate irrespective of the presence of SHD. Longer hospital stay and potentially a higher risk of periprocedural complications should be considered when discussing this treatment option with patients.

18.
Sci Rep ; 12(1): 9139, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35650230

RESUMO

Ultra-high-density (UHD) mapping can improve scar area detection and fast activation mapping in patients undergoing catheter ablation of ventricular tachycardia (VT). The aim of the present study was to compare the outcome after VT ablation guided by UHD and conventional point-by-point 3D-mapping. The acute and long-term ablation outcome of 61 consecutive patients with UHD mapping (64-electrode mini-basket catheter) was compared to 61 consecutive patients with conventional point-by-point 3D-mapping using a 3.5 mm tip catheter. Patients, whose ablation was guided by UHD mapping had an improved 24-months outcome in comparison to patients with conventional mapping (cumulative incidence estimate of the combination of recurrence or disease-related death of 52.4% (95% confidence interval (CI) [36.9-65.7]; recurrence: n = 25; disease-related death: n = 4) versus 69.6% (95% CI [55.9-79.8]); recurrence: n = 31; disease-related death n = 11). In a cause-specific Cox proportional hazards model, UHD mapping (hazard ratio (HR) 0.623; 95% CI [0.390-0.995]; P = 0.048) and left ventricular ejection fraction > 30% (HR 0.485; 95% CI [0.290-0.813]; P = 0.006) were independently associated with lower rates of recurrence or disease-related death. Other procedural parameters were similar in both groups. In conclusion, UHD mapping during VT ablation was associated with fewer VT recurrences or disease-related deaths during long-term follow-up in comparison to conventional point-by-point mapping. Complication rates and other procedural parameters were similar in both groups.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Mapeamento Potencial de Superfície Corporal , Ablação por Cateter/efeitos adversos , Humanos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
19.
J Mol Cell Cardiol ; 163: 97-105, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34634355

RESUMO

BACKGROUND: One third of heart failure patients exhibit dyssynchronized electromechanical activity of the heart (evidenced by a broad QRS-complex). Cardiac resynchronization therapy (CRT) in the form of biventricular pacing improves cardiac output and clinical outcome of responding patients. Technically demanding and laborious large animal models have been developed to better predict responders of CRT and to investigate molecular mechanisms of dyssynchrony and CRT. The aim of this study was to establish a first humanized in vitro model of dyssynchrony and CRT. METHODS: Cardiomyocytes were differentiated from human induced pluripotent stem cells and cast into a fibrin matrix to produce engineered heart tissue (EHT). EHTs were either field stimulated in their entirety (symmetrically) or excited locally from one end (asymmetrically) or they were allowed to beat spontaneously. RESULTS: Asymmetrical pacing led to a depolarization wave from one end to the other end, which was visualized in human EHT transduced with a fast genetic Ca2+-sensor (GCaMP6f) arguing for dyssynchronous excitation. Symmetrical pacing in contrast led to an instantaneous (synchronized) Ca2+-signal throughout the EHT. To investigate acute and long-term functional effects, spontaneously beating human EHTs (0.5-0.8 Hz) were divided into a non-paced control group, a symmetrically and an asymmetrically paced group, each stimulated at 1 Hz. Symmetrical pacing was clearly superior to asymmetrical pacing or no pacing regarding contractile force both acutely and even more pronounced after weeks of continuous stimulation. Contractile dysfunction that can be evoked by an increased afterload was aggravated in the asymmetrically paced group. Consistent with reports from paced dogs, p38MAPK and CaMKII-abundance was higher under asymmetrical than under symmetrical pacing while pAKT was considerably lower. CONCLUSIONS: This model allows for long-term pacing experiments mimicking electrical dyssynchrony vs. synchrony in vitro. Combined with force measurement and afterload stimulus manipulation, it provides a robust new tool to gain insight into the biology of dyssynchrony and CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Células-Tronco Pluripotentes Induzidas , Animais , Estimulação Cardíaca Artificial , Cães , Humanos , Miócitos Cardíacos , Resultado do Tratamento
20.
Clin Appl Thromb Hemost ; 27: 10760296211021171, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34184557

RESUMO

Left atrial (LA) thrombus formation is the presumed origin of thromboembolic complications in patients with atrial fibrillation (AF). Beyond clinical risk factors, the factors causing formation of LA thrombi are not well known. In this case-control study, we analyzed clinical characteristics and genetic thrombophilia markers (factor V Leiden (FVL), prothrombin G20210A (FIIV), Tyr2561 variant of von Willebrand factor (VWF-V)) in 42 patients with AF and LA thrombus (LAT) and in 68 control patients with AF without LAT (CTR). Patients with LAT had more clinical conditions predisposing to stroke (mean CHA2DS2-VASc-score 3.4 ± 1.5 vs. 1.9 ± 1.4; P < 0.001), a higher LA volume (96 ± 32 vs. 76 ± 21 ml, P = 0.002) and lower LA appendage emptying velocity (0.21 ± 0.11vs. 0.43 ± 0.19 m/s, P < 0.001). Prevalence of FVL, FIIV and VWF-V mutations was not different, but in the subgroup of patients <65 years (y) there was a tendency for a higher incidence of VWF-V with a prevalence of 27% (LAT <65 y) vs. 7% (CTR <65 y, P = 0.066). These findings warrant further investigation of the VWF-V as a risk factor for LA thrombogenesis in younger patients.


Assuntos
Fibrilação Atrial/complicações , Ecocardiografia Transesofagiana/métodos , Trombose/genética , Idoso , Estudos de Casos e Controles , Humanos , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA