Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Int J Mol Sci ; 25(6)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38542524

RESUMO

The emergence of SARS-CoV-2 mutations poses significant challenges to diagnostic tests, as these mutations can reduce the sensitivity of commonly used RT-PCR assays. Therefore, there is a need to design diagnostic assays with multiple targets to enhance sensitivity. In this study, we identified a novel diagnostic target, the nsp10 gene, using nanopore sequencing. Firstly, we determined the analytical sensitivity and specificity of our COVID-19-nsp10 assay. The COVID-19-nsp10 assay had a limit of detection of 74 copies/mL (95% confidence interval: 48-299 copies/mL) and did not show cross-reactivity with other respiratory viruses. Next, we determined the diagnostic performance of the COVID-19-nsp10 assay using 261 respiratory specimens, including 147 SARS-CoV-2-positive specimens belonging to the ancestral strain and Alpha, Beta, Gamma, Delta, Mu, Eta, Kappa, Theta and Omicron lineages. Using a LightMix E-gene RT-PCR assay as the reference method, the diagnostic sensitivity and specificity of the COVID-19-nsp10 assay were found to be 100%. The median Cp values for the LightMix E-gene RT-PCR and our COVID-19-nsp10 RT-PCR were 22.48 (range: 12.95-36.60) and 25.94 (range 16.37-36.87), respectively. The Cp values of the COVID-19-nsp10 RT-PCR assay correlated well with those of the LightMix E-gene RT-PCR assay (Spearman's ρ = 0.968; p < 0.0001). In conclusion, nsp10 is a suitable target for a SARS-CoV-2 RT-PCR assay.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Teste para COVID-19 , Sensibilidade e Especificidade
2.
Emerg Microbes Infect ; 12(1): 2157338, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36482706

RESUMO

Cytokine dynamics in patients with coronavirus disease 2019 (COVID-19) have been studied in blood but seldomly in respiratory specimens. We studied different cell markers and cytokines in fresh nasopharyngeal swab specimens for the diagnosis and for stratifying the severity of COVID-19. This was a retrospective case-control study comparing Myeloperoxidase (MPO), Adenosine deaminase (ADA), C-C motif chemokine ligand 22 (CCL22), Tumour necrosis factor alpha (TNFα) and Interleukin-6 (IL-6) mRNA expression in 490 (327 patients and 163 control) nasopharyngeal specimens from 317 (154 COVID-19 and 163 control) hospitalized patients. Of the 154 COVID-19 cases, 46 died. Both total and normalized MPO, ADA, CCL22, TNFα, and IL-6 mRNA expression levels were significantly higher in the nasopharyngeal specimens of infected patients when compared with controls, with ADA showing better performance (OR 5.703, 95% CI 3.424-9.500, p < 0.001). Receiver operating characteristics (ROC) curve showed that the cut-off value of normalized ADA mRNA level at 2.37 × 10-3 had a sensitivity of 81.8% and specificity of 83.4%. While patients with severe COVID-19 had more respiratory symptoms, and elevated lactate dehydrogenase, multivariate analysis showed that severe COVID-19 patients had lower CCL22 mRNA (OR 0.211, 95% CI 0.060-0.746, p = 0.016) in nasopharyngeal specimens, while lymphocyte count, C-reactive protein, and viral load in nasopharyngeal specimens did not correlate with disease severity. In summary, ADA appears to be a better biomarker to differentiate between infected and uninfected patients, while CCL22 has the potential in stratifying the severity of COVID-19.


Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico , Interleucina-6/genética , Fator de Necrose Tumoral alfa/genética , Estudos Retrospectivos , Adenosina Desaminase/genética , Adenosina Desaminase/análise , Adenosina Desaminase/metabolismo , Estudos de Casos e Controles , Peroxidase , Ligantes , SARS-CoV-2/genética , SARS-CoV-2/metabolismo , Citocinas , Quimiocinas , Nasofaringe , Quimiocina CCL22
3.
Microbiol Spectr ; 10(6): e0196222, 2022 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-36445095

RESUMO

Accurate and simple diagnostic tests for coronavirus disease 2019 (COVID-19) are essential components of the pandemic response. In this study, we evaluated a one-tube reverse transcription-loop-mediated isothermal amplification (RT-LAMP) assay coupled with clustered regularly interspaced short palindromic repeat (CRISPR)-associated protein-mediated endpoint detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA in clinical samples. RT-LAMP-CRISPR is fast and affordable, does not require bulky thermocyclers, and minimizes carryover contamination risk. Results can be read either visually or with a fluorometer. RT-LAMP-CRISPR assays using primers targeting a highly expressed nsp8 gene and previously described nucleocapsid (N) gene primers were designed. The analytical characteristics and diagnostic performance of RT-LAMP-CRISPR assays were compared to those of a commercial real-time RT-PCR E gene assay. The limits of detection (LODs) of the nsp8 and N RT-LAMP-CRISPR assays were 750 and 2,000 copies/mL, which were higher than that of the commercial real-time RT-PCR assay (31.3 copies/mL). Despite the higher LOD, RT-LAMP-CRISPR assays showed diagnostic sensitivity and specificity of 98.6% and 100%, respectively, equivalent to those of the real-time RT-PCR assay (P = 0.5). The median fluorescence reading from the nsp8 assay (378.3 raw fluorescence unit [RFU] [range, 215.6 to 592.6]) was significantly higher than that of the N gene assay (342.0 RFU [range, 143.0 to 576.6]) (P < 0.0001). In conclusion, we demonstrate that RT-LAMP-CRISPR assays using primers rationally designed from highly expressed gene targets are highly sensitive, specific, and easy to perform. Such assays are a valuable asset in resource-limited settings. IMPORTANCE Accurate tests for the diagnosis of SARS-CoV-2, the virus causing coronavirus disease 2019 (COVID-19), are important for timely treatment and infection control decisions. Conventional tests such as real-time reverse transcription-PCR (RT-PCR) require specialized equipment and are expensive. On the other hand, rapid antigen tests suffer from a lack of sensitivity. In this study, we describe a novel assay format for the diagnosis of COVID-19 that is based on principles of loop-mediated isothermal amplification (LAMP) and clustered regularly interspaced short palindromic repeat (CRISPR)-Cas chemistry. A major advantage of this assay format is that it does not require expensive equipment to perform, and results can be read visually. This method proved to be fast, easy to perform, and inexpensive. The test compared well against an RT-PCR assay in terms of the ability to detect SARS-CoV-2 RNA in clinical samples. No false-positive test results were observed. The new assay format is ideal for SARS-CoV-2 diagnosis in resource-limited settings.


Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2/genética , Teste para COVID-19 , RNA Viral/genética , Técnicas de Diagnóstico Molecular/métodos , Primers do DNA
4.
Clin Infect Dis ; 75(1): e76-e81, 2022 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-35234870

RESUMO

BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can infect human and other mammals, including hamsters. Syrian (Mesocricetus auratus) and dwarf (Phodopus sp.) hamsters are susceptible to SARS-CoV-2 infection in the laboratory setting. However, pet shop-related Coronavirus Disease 2019 (COVID-19) outbreaks have not been reported. METHODS: We conducted an investigation of a pet shop-related COVID-19 outbreak due to Delta variant AY.127 involving at least 3 patients in Hong Kong. We tested samples collected from the patients, environment, and hamsters linked to this outbreak and performed whole genome sequencing analysis of the reverse transcription polymerase chain reaction (RT-PCR)-positive samples. RESULTS: The patients included a pet shop keeper (Patient 1), a female customer of the pet shop (Patient 2), and the husband of Patient 2 (Patient 3). Investigation showed that 17.2% (5/29) and 25.5% (13/51) environmental specimens collected from the pet shop and its related warehouse, respectively, tested positive for SARS-CoV-2 RNA by RT-PCR. Among euthanized hamsters randomly collected from the storehouse, 3% (3/100) tested positive for SARS-CoV-2 RNA by RT-PCR and seropositive for anti-SARS-CoV-2 antibody by enzyme immunoassay. Whole genome analysis showed that although all genomes from the outbreak belonged to the Delta variant AY.127, there were at least 3 nucleotide differences among the genomes from different patients and the hamster cages. Genomic analysis suggests that multiple strains have emerged within the hamster population, and these different strains have likely transmitted to human either via direct contact or via the environment. CONCLUSIONS: Our study demonstrated probable hamster-to-human transmission of SARS-CoV-2. As pet trading is common around the world, this can represent a route of international spread of this pandemic virus.


Assuntos
COVID-19 , SARS-CoV-2 , Animais , Cricetinae , Surtos de Doenças , Feminino , Hong Kong/epidemiologia , Humanos , Mamíferos , RNA Viral/genética , SARS-CoV-2/genética
5.
Clin Infect Dis ; 75(2): 288-296, 2022 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-34718428

RESUMO

BACKGROUND: Hepatitis E virus (HEV) variants belonging to Orthohepevirus species A (HEV-A) are the primary cause of human hepatitis E. However, we previously reported that Orthohepevirus species C genotype 1 (HEV-C1), a divergent HEV variant commonly found in rats, also causes hepatitis in humans. Here, we present a clinical-epidemiological investigation of human HEV-C1 infections detected in Hong Kong, with an emphasis on outcomes in immunocompromised individuals. METHODS: A surveillance system for detecting human HEV-C1 infections was established in Hong Kong. Epidemiological and clinical characteristics of HEV-C1 cases identified via this system between 1 August 2019 and 31 December 2020 were retrieved. Phylogenetic analysis of HEV-C1 strain sequences was performed. Infection outcomes of immunocompromised individuals with HEV-A and HEV-C1 infections were analyzed. RESULTS: HEV-C1 accounted for 8 of 53 (15.1%) reverse-transcription polymerase chain reaction (RT-PCR)-confirmed HEV infections in Hong Kong during the study period, raising the total number of HEV-C1 infections detected in the city to 16. Two distinct HEV-C1 strain groups caused human infections. Patients were elderly and/or immunocompromised; half tested negative for HEV immunoglobulin M. Cumulatively, HEV-C1 accounted for 9 of 21 (42.9%) cases of hepatitis E recorded in immunocompromised patients in Hong Kong. Immunocompromised HEV-C1 patients progressed to persistent hepatitis at similar rates (7/9 [77.8%]) as HEV-A patients (10/12 [75%]). HEV-C1 patients responded to oral ribavirin, although response to first course was sometimes poor or delayed. CONCLUSIONS: Dedicated RT-PCR-based surveillance detected human HEV-C1 cases that evade conventional hepatitis E diagnostic testing. Immunosuppressed HEV-C1-infected patients frequently progress to persistent HEV-C1 infection, for which ribavirin is a suitable treatment option.


Assuntos
Hepatite C , Vírus da Hepatite E , Hepatite E , Idoso , Animais , Vírus da Hepatite E/genética , Hong Kong/epidemiologia , Humanos , Filogenia , RNA Viral/genética , Ratos , Ribavirina
6.
Expert Rev Mol Diagn ; 21(7): 741-747, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34014785

RESUMO

OBJECTIVES: Sensitive molecular diagnostic assays are essential for COVID-19 diagnosis. We evaluated the Hecin Scientific SARS-CoV-2 nucleic acid test kit, a dual-target real-time RT-PCR assay targeting the SARS-CoV-2 N and ORF1ab genes. METHODS: The Hecin test kit's diagnostic performance in detecting SARS-CoV-2 RNA was compared to the LightMix Modular SARS and Wuhan CoV E-gene kit (TIB Molbiol) and an in-house single-tube nested real-time RT-PCR using 296 clinical specimens, 11 proficiency testing samples, and 30 low-positive deep throat saliva and nasopharyngeal swab (NPS) samples pooled into negative samples in ratios of 1:5, 1:10, and 1:30. RESULTS: The limit-of-detection of the Hecin test kit was around 500 dC/mL for the N and ORF1ab targets. Sensitivity and specificity of the Hecin test kit were 98.1% (95% CI: 93.4-99.8%) and 100% (98.1-100%), respectively, when measured against the reference method. The Hecin test kit showed fair sensitivity (80%) in low-positive NPS samples pooled in ratios of 1:5 and 1:10. Its performance in pooled samples could be dramatically improved by adjusting the assay Ct cutoff. CONCLUSION: The Hecin test kit enables sensitive and specific detection of SARS-CoV-2 in clinical samples and pooled samples.


Assuntos
Teste de Ácido Nucleico para COVID-19 , COVID-19 , Reação em Cadeia da Polimerase em Tempo Real , Reação em Cadeia da Polimerase Via Transcriptase Reversa , SARS-CoV-2/genética , Manejo de Espécimes , COVID-19/diagnóstico , COVID-19/genética , Humanos , RNA Viral/genética
7.
Hepatology ; 73(1): 10-22, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-31960460

RESUMO

BACKGROUND AND AIMS: Hepatitis E virus (HEV) variants causing human infection predominantly belong to HEV species A (HEV-A). HEV species C genotype 1 (HEV-C1) circulates in rats and is highly divergent from HEV-A. It was previously considered unable to infect humans, but the first case of human HEV-C1 infection was recently discovered in Hong Kong. The aim of this study is to further describe the features of this zoonosis in Hong Kong. APPROACH AND RESULTS: We conducted a territory-wide prospective screening study for HEV-C1 infection over a 31-month period. Blood samples from 2,860 patients with abnormal liver function (n = 2,201) or immunosuppressive conditions (n = 659) were screened for HEV-C1 RNA. In addition, 186 captured commensal rats were screened for HEV-C1 RNA. Sequences of human-derived and rat-derived HEV-C1 isolates were compared. Epidemiological and clinical features of HEV-C1 infection were analyzed. HEV-C1 RNA was detected in 6/2,201 (0.27%) patients with hepatitis and 1/659 (0.15%) immunocompromised persons. Including the previously reported case, eight HEV-C1 infections were identified, including five in patients who were immunosuppressed. Three patients had acute hepatitis, four had persistent hepatitis, and one had subclinical infection without hepatitis. One patient died of meningoencephalitis, and HEV-C1 was detected in cerebrospinal fluid. HEV-C1 hepatitis was generally milder than HEV-A hepatitis. HEV-C1 RNA was detected in 7/186 (3.76%) rats. One HEV-C1 isolate obtained from a rat captured near the residences of patients was closely related to the major outbreak strain. CONCLUSIONS: HEV-C1 is a cause of hepatitis E in humans in Hong Kong. Immunosuppressed individuals are susceptible to persistent HEV-C1 infection and extrahepatic manifestations. Subclinical HEV-C1 infection threatens blood safety. Tests for HEV-C1 are required in clinical laboratories.


Assuntos
Reservatórios de Doenças/veterinária , Vírus da Hepatite E/genética , Hepatite E/epidemiologia , Hepatite E/transmissão , Idoso , Idoso de 80 Anos ou mais , Animais , Reservatórios de Doenças/virologia , Feminino , Vírus da Hepatite E/classificação , Hepatite Viral Animal/transmissão , Hong Kong/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Filogenia , Estudos Prospectivos , RNA Viral/genética , Ratos , Zoonoses/transmissão , Zoonoses/virologia
8.
Expert Rev Mol Diagn ; 20(12): 1253-1258, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32893699

RESUMO

OBJECTIVES: Accurate assays for hepatitis C virus (HCV) quantitation and genotyping are important for the management of HCV infection. In this study, we evaluated the performance of cobas HCV and cobas HCV GT assays (Roche) for HCV quantitation and genotyping on the cobas 4800 System. METHODS: We compared the performance of the cobas HCV assays with another commercial system (Abbott m2000) using a panel of well-characterized patient samples and proficiency testing samples. RESULTS: The limit-of-detection of the cobas HCV assay in our center was higher (15 IU/mL) than the manufacturer claim (9.2 IU/mL). The assay showed high analytical specificity, accuracy, precision, and linearity. Performance was congruent with the RealTime HCV assay (Abbott). For genotyping, the cobas HCV GT assay only showed moderate agreement with the RealTime HCV Genotype II assay (kappa = 0.550). The cobas assay outperformed the RealTime assay for typing HCV genotypes 1b and 6 (p = 0.033). CONCLUSION: Our results confirm that the cobas 4800 System is a reliable platform for HCV quantitation and genotyping. The cobas HCV GT assay is a good choice for genotype 1b/6 endemic areas in east Asia, clearly outperforming the RealTime HCV Genotype II assay.


Assuntos
Genótipo , Técnicas de Genotipagem , Hepacivirus/genética , Hepatite C/diagnóstico , Hepatite C/virologia , Técnicas de Genotipagem/métodos , Técnicas de Genotipagem/normas , Humanos , RNA Viral , Kit de Reagentes para Diagnóstico , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Carga Viral
9.
Int J Mol Sci ; 21(16)2020 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-32784770

RESUMO

Sensitive molecular assays are critical for coronavirus disease 2019 (COVID-19) diagnosis. Here, we designed and evaluated two single-tube nested (STN) real-time RT-PCR assays, targeting SARS-CoV-2 RdRp/Hel and N genes. Both STN assays had a low limit of detection and did not cross react with other human coronaviruses and respiratory viruses. Using 213 initial respiratory specimens from suspected COVID-19 patients, the sensitivity of both the STN COVID-19-RdRp/Hel and the STN COVID-19-N assays was 100% (99/99), while that of the comparator non-nested N assay was 95% (94/99). Among 108 follow-up specimens from confirmed COVID-19 patients who tested negative by the non-nested COVID-19-RdRp/Hel assay, 28 (25.9%) were positive for SARS-CoV-2 by the STN COVID-19-RdRp/Hel or the STN COVID-19-N assay. To evaluate the performance of our novel STN assays in pooled specimens, we created four sample pools, with each pool consisting of one low positive specimen and 49 negative specimens. While the non-nested COVID-19-RdRp/Hel assay was positive in only one of four sample pools (25%), both of the STN assays were positive in two of four samples pools (50%). In conclusion, the STN assays are highly sensitive and specific for SARS-CoV-2 detection. Their boosted sensitivity offers advantages in non-traditional COVID-19 testing algorithms such as saliva screening and pooled sample screening during massive screening.


Assuntos
Betacoronavirus/genética , Infecções por Coronavirus/virologia , Técnicas de Diagnóstico Molecular/métodos , Pneumonia Viral/virologia , Reação em Cadeia da Polimerase em Tempo Real/métodos , Betacoronavirus/patogenicidade , COVID-19 , Infecções por Coronavirus/diagnóstico , Proteínas do Nucleocapsídeo de Coronavírus , RNA-Polimerase RNA-Dependente de Coronavírus , Humanos , Técnicas de Diagnóstico Molecular/normas , Proteínas do Nucleocapsídeo/genética , Pandemias , Fosfoproteínas , Pneumonia Viral/diagnóstico , RNA Polimerase Dependente de RNA/genética , Reação em Cadeia da Polimerase em Tempo Real/normas , Mucosa Respiratória/virologia , SARS-CoV-2 , Sensibilidade e Especificidade , Proteínas não Estruturais Virais/genética
10.
J Clin Virol ; 129: 104476, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32516739

RESUMO

BACKGROUND: Rapid and sensitive diagnostic assays for SARS-CoV-2 detection are required for prompt patient management and infection control. The analytical and clinical performances of LightMix® Modular SARS and Wuhan CoV E-gene kit, a widely used commercial assay for SARS-CoV-2 detection, have not been well studied. OBJECTIVE: To evaluate the performance characteristics of the LightMix® E-gene kit in comparison with well-validated in-house developed COVID-19 RT-PCR assays. STUDY DESIGN: Serial dilutions of SARS-CoV-2 culture isolate extracts were used for analytical sensitivity evaluation. A total of 289 clinical specimens from 186 patients with suspected COVID-19 and 8 proficiency testing (PT) samples were used to evaluate the diagnostic performance of the LightMix® E-gene kit against in-house developed COVID-19-RdRp/Hel and COVID-19-N RT-PCR assays. RESULTS: The LightMix® E-gene kit had a limit of detection of 1.8 × 10-1 TCID50/mL, which was one log10 lower than those of the two in-house RT-PCR assays. The LightMix® E-gene kit (149/289 [51.6%]) had similar sensitivity as the in-house assays (144/289 [49.8%] for RdRp/Hel and 146/289 [50.5%] for N). All three assays gave correct results for all the PT samples. Cycle threshold (Cp) values of the LightMix® E-gene kit and in-house assays showed excellent correlation. Reproducibility of the Cp values was satisfactory with intra- and inter-assay coefficient of variation values <5%. Importantly, the LightMix® E-gene kit, when used as a stand-alone assay, was equally sensitive as testing algorithms using multiple COVID-19 RT-PCR assays. CONCLUSIONS: The LightMix® E-gene kit is a rapid and sensitive assay for SARS-CoV-2 detection. It has fewer verification requirements compared to laboratory-developed tests.


Assuntos
Betacoronavirus/isolamento & purificação , Técnicas de Laboratório Clínico/métodos , Infecções por Coronavirus/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Pneumonia Viral/diagnóstico , RNA Viral/análise , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Betacoronavirus/genética , COVID-19 , Teste para COVID-19 , Feminino , Humanos , Limite de Detecção , Masculino , Pessoa de Meia-Idade , Pandemias , RNA Viral/genética , Padrões de Referência , Reprodutibilidade dos Testes , SARS-CoV-2 , Sensibilidade e Especificidade , Fatores de Tempo , Adulto Jovem
11.
Lancet Infect Dis ; 20(9): 1051-1060, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32539986

RESUMO

BACKGROUND: A cruise ship is a closed-off environment that simulates the basic functioning of a city in terms of living conditions and interpersonal interactions. Thus, the Diamond Princess cruise ship, which was quarantined because of an onboard outbreak of COVID-19 in February, 2020, provides an opportunity to define the shedding pattern of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and patient antibody responses before and after the onset of symptoms. METHODS: We recruited adult (≥18 years) passengers from Hong Kong who had been on board the Diamond Princess cruise ship docked in Yokohama, Japan in February, 2020. All participants had been found to be negative for SARS-CoV-2 by RT-PCR 4 days before disembarking and were transferred to further quarantine in a public estate in Hong Kong, where they were recruited. Participants were prospectively screened by quantitative RT-PCR (RT-qPCR) of nasopharyngeal and throat swabs, and serum IgG and IgM against internal nucleoprotein and the surface spike receptor-binding protein (RBD) of SARS-CoV-2 at baseline (upon entering quarantine) and on days 4, 8, and 12 of quarantine. FINDINGS: On Feb 22, 2020, 215 adults were recruited, of whom nine (4%; 95% CI 2-8) were positive for SARS-CoV-2 by RT-qPCR or serology and were hospitalised. Of these nine patients, nasopharyngeal swab RT-qPCR was positive in eight patients (89%; 57-99) at baseline. All nine patients were positive for anti-RBD IgG by day 8. Eight (89%; 57-99) were simultaneously positive for nasopharyngeal swab RT-PCR and anti-RBD IgG. One patient who was positive for anti-RBD IgG and had a negative viral load had multifocal peripheral ground-glass changes on high-resolution CT that were typical of COVID-19. Five patients (56%; 27-81) with ground-glass changes on high-resolution CT were found to have higher anti-nucleoprotein-IgG OD values on day 8 and 12 and anti-RBD IgG OD value on day 12 than patients without ground-glass changes. Six (67%; 35-88) patients remained asymptomatic throughout the 14-day quarantine period. INTERPRETATION: Patients with COVID-19 can develop asymptomatic lung infection with viral shedding and those with evidence of pneumonia on imaging tend to have an increased antibody response. Positive IgG or IgM confirmed infection of COVID-19 in both symptomatic and asymptomatic patients. A combination of RT-PCR and serology should be implemented for case finding and contact tracing to facilitate early diagnosis, prompt isolation, and treatment. FUNDING: Shaw Foundation Hong Kong; Sanming-Project of Medicine (Shenzhen); High Level-Hospital Program (Guangdong Health Commission).


Assuntos
Betacoronavirus/fisiologia , Infecções por Coronavirus/virologia , Surtos de Doenças , Pneumonia Viral/virologia , Soroconversão , Eliminação de Partículas Virais , Adulto , Idoso , Betacoronavirus/genética , Betacoronavirus/imunologia , COVID-19 , Busca de Comunicante , Infecções por Coronavirus/diagnóstico por imagem , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/prevenção & controle , Feminino , Hong Kong , Humanos , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Pandemias/prevenção & controle , Pneumonia Viral/diagnóstico por imagem , Pneumonia Viral/epidemiologia , Pneumonia Viral/prevenção & controle , Quarentena , SARS-CoV-2 , Navios , Tórax/diagnóstico por imagem , Carga Viral , Adulto Jovem
12.
Lancet ; 395(10238): 1695-1704, 2020 05 30.
Artigo em Inglês | MEDLINE | ID: mdl-32401715

RESUMO

BACKGROUND: Effective antiviral therapy is important for tackling the coronavirus disease 2019 (COVID-19) pandemic. We assessed the efficacy and safety of combined interferon beta-1b, lopinavir-ritonavir, and ribavirin for treating patients with COVID-19. METHODS: This was a multicentre, prospective, open-label, randomised, phase 2 trial in adults with COVID-19 who were admitted to six hospitals in Hong Kong. Patients were randomly assigned (2:1) to a 14-day combination of lopinavir 400 mg and ritonavir 100 mg every 12 h, ribavirin 400 mg every 12 h, and three doses of 8 million international units of interferon beta-1b on alternate days (combination group) or to 14 days of lopinavir 400 mg and ritonavir 100 mg every 12 h (control group). The primary endpoint was the time to providing a nasopharyngeal swab negative for severe acute respiratory syndrome coronavirus 2 RT-PCR, and was done in the intention-to-treat population. The study is registered with ClinicalTrials.gov, NCT04276688. FINDINGS: Between Feb 10 and March 20, 2020, 127 patients were recruited; 86 were randomly assigned to the combination group and 41 were assigned to the control group. The median number of days from symptom onset to start of study treatment was 5 days (IQR 3-7). The combination group had a significantly shorter median time from start of study treatment to negative nasopharyngeal swab (7 days [IQR 5-11]) than the control group (12 days [8-15]; hazard ratio 4·37 [95% CI 1·86-10·24], p=0·0010). Adverse events included self-limited nausea and diarrhoea with no difference between the two groups. One patient in the control group discontinued lopinavir-ritonavir because of biochemical hepatitis. No patients died during the study. INTERPRETATION: Early triple antiviral therapy was safe and superior to lopinavir-ritonavir alone in alleviating symptoms and shortening the duration of viral shedding and hospital stay in patients with mild to moderate COVID-19. Future clinical study of a double antiviral therapy with interferon beta-1b as a backbone is warranted. FUNDING: The Shaw-Foundation, Richard and Carol Yu, May Tam Mak Mei Yin, and Sanming Project of Medicine.


Assuntos
Infecções por Coronavirus/tratamento farmacológico , Interferon beta-1b/uso terapêutico , Lopinavir/uso terapêutico , Pneumonia Viral/tratamento farmacológico , Ribavirina/uso terapêutico , Ritonavir/uso terapêutico , Adulto , Betacoronavirus , COVID-19 , Combinação de Medicamentos , Quimioterapia Combinada , Feminino , Hong Kong , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias , SARS-CoV-2 , Tratamento Farmacológico da COVID-19
13.
Int J Mol Sci ; 21(7)2020 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-32276333

RESUMO

The pandemic novel coronavirus infection, Coronavirus Disease 2019 (COVID-19), has affected at least 190 countries or territories, with 465,915 confirmed cases and 21,031 deaths. In a containment-based strategy, rapid, sensitive and specific testing is important in epidemiological control and clinical management. Using 96 SARS-CoV-2 and 104 non-SARS-CoV-2 coronavirus genomes and our in-house program, GolayMetaMiner, four specific regions longer than 50 nucleotides in the SARS-CoV-2 genome were identified. Primers were designed to target the longest and previously untargeted nsp2 region and optimized as a probe-free real-time reverse transcription-polymerase chain reaction (RT-PCR) assay. The new COVID-19-nsp2 assay had a limit of detection (LOD) of 1.8 TCID50/mL and did not amplify other human-pathogenic coronaviruses and respiratory viruses. Assay reproducibility in terms of cycle threshold (Cp) values was satisfactory, with the total imprecision (% CV) values well below 5%. Evaluation of the new assay using 59 clinical specimens from 14 confirmed cases showed 100% concordance with our previously developed COVID-19-RdRp/Hel reference assay. A rapid, sensitive, SARS-CoV-2-specific real-time RT-PCR assay, COVID-19-nsp2, was developed.


Assuntos
Betacoronavirus/genética , Técnicas de Laboratório Clínico/métodos , Infecções por Coronavirus/diagnóstico , Genoma Viral , Pneumonia Viral/diagnóstico , RNA Viral/análise , Reação em Cadeia da Polimerase em Tempo Real , COVID-19 , Teste para COVID-19 , Vacinas contra COVID-19 , Humanos , Pandemias , Reprodutibilidade dos Testes , Reação em Cadeia da Polimerase Via Transcriptase Reversa , SARS-CoV-2 , Sensibilidade e Especificidade
14.
Gastroenterology ; 159(1): 81-95, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32251668

RESUMO

BACKGROUND & AIMS: Infection with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) causes coronavirus disease 2019 (COVID-19), which has been characterized by fever, respiratory, and gastrointestinal symptoms as well as shedding of virus RNA into feces. We performed a systematic review and meta-analysis of published gastrointestinal symptoms and detection of virus in stool and also summarized data from a cohort of patients with COVID-19 in Hong Kong. METHODS: We collected data from the cohort of patients with COVID-19 in Hong Kong (N = 59; diagnosis from February 2 through February 29, 2020),and searched PubMed, Embase, Cochrane, and 3 Chinese databases through March 11, 2020, according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. We analyzed pooled data on the prevalence of overall and individual gastrointestinal symptoms (loss of appetite, nausea, vomiting, diarrhea, and abdominal pain or discomfort) using a random effects model. RESULTS: Among the 59 patients with COVID-19 in Hong Kong, 15 patients (25.4%) had gastrointestinal symptoms, and 9 patients (15.3%) had stool that tested positive for virus RNA. Stool viral RNA was detected in 38.5% and 8.7% among those with and without diarrhea, respectively (P = .02). The median fecal viral load was 5.1 log10 copies per milliliter in patients with diarrhea vs 3.9 log10 copies per milliliter in patients without diarrhea (P = .06). In a meta-analysis of 60 studies comprising 4243 patients, the pooled prevalence of all gastrointestinal symptoms was 17.6% (95% confidence interval [CI], 12.3-24.5); 11.8% of patients with nonsevere COVID-19 had gastrointestinal symptoms (95% CI, 4.1-29.1), and 17.1% of patients with severe COVID-19 had gastrointestinal symptoms (95% CI, 6.9-36.7). In the meta-analysis, the pooled prevalence of stool samples that were positive for virus RNA was 48.1% (95% CI, 38.3-57.9); of these samples, 70.3% of those collected after loss of virus from respiratory specimens tested positive for the virus (95% CI, 49.6-85.1). CONCLUSIONS: In an analysis of data from the Hong Kong cohort of patients with COVID-19 and a meta-analysis of findings from publications, we found that 17.6% of patients with COVID-19 had gastrointestinal symptoms. Virus RNA was detected in stool samples from 48.1% patients, even in stool collected after respiratory samples had negative test results. Health care workers should therefore exercise caution in collecting fecal samples or performing endoscopic procedures in patients with COVID-19, even during patient recovery.


Assuntos
Betacoronavirus/isolamento & purificação , Infecções por Coronavirus/prevenção & controle , Diarreia/virologia , Fezes/virologia , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Carga Viral , Betacoronavirus/genética , Betacoronavirus/patogenicidade , COVID-19 , Teste para COVID-19 , Técnicas de Laboratório Clínico , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/transmissão , Diarreia/diagnóstico , Diarreia/epidemiologia , Endoscopia Gastrointestinal/normas , Trato Gastrointestinal/diagnóstico por imagem , Trato Gastrointestinal/virologia , Hong Kong/epidemiologia , Humanos , Controle de Infecções/normas , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Pneumonia Viral/diagnóstico , Pneumonia Viral/epidemiologia , Pneumonia Viral/transmissão , Prevalência , RNA Viral/isolamento & purificação , SARS-CoV-2
15.
J Clin Microbiol ; 58(5)2020 04 23.
Artigo em Inglês | MEDLINE | ID: mdl-32132187

RESUMO

Accurate detection of influenza A virus (IAV) is crucial for patient management, infection control, and epidemiological surveillance. The World Health Organization and the Centers for Disease Control and Prevention have recommended using the M gene as the diagnostic gene target for reverse-transcription-PCR (RT-PCR). However, M gene RT-PCR has reduced sensitivity for recent IAV due to novel gene mutations. Here, we sought to identify novel diagnostic targets for the molecular detection of IAV using long-read third-generation sequencing. Direct nanopore sequencing from 18 nasopharyngeal specimens and one saliva specimen showed that the 5' and 3' ends of the PB2 gene and the entire NS gene were highly abundant. Primers selected for PB2 and NS genes were well matched with seasonal or avian IAV gene sequences. Our novel PB2 and NS gene real-time RT-PCR assays showed limits of detection similar to or lower than that of M gene RT-PCR and achieved 100% sensitivity and specificity in the detection of A(H1N1), A(H3N2), and A(H7N9) in nasopharyngeal and saliva specimens. For 10 patients with IAV detected by M gene RT-PCR conversion in sequentially collected specimens, NS and/or PB2 gene RT-PCR was positive in 2 (20%) of the initial specimens that were missed by M gene RT-PCR. In conclusion, we have shown that PB2 or NS gene RT-PCRs are suitable alternatives to the recommended M gene RT-PCR for diagnosis of IAV. Long-read nanopore sequencing facilitates the identification of novel diagnostic targets.


Assuntos
Vírus da Influenza A Subtipo H1N1 , Subtipo H7N9 do Vírus da Influenza A , Influenza Humana , Sequenciamento por Nanoporos , Animais , Humanos , Vírus da Influenza A Subtipo H1N1/genética , Vírus da Influenza A Subtipo H3N2/genética , Influenza Humana/diagnóstico , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Sensibilidade e Especificidade
16.
J Clin Microbiol ; 58(5)2020 04 23.
Artigo em Inglês | MEDLINE | ID: mdl-32132196

RESUMO

On 31 December 2019, the World Health Organization was informed of a cluster of cases of pneumonia of unknown etiology in Wuhan, China. Subsequent investigations identified a novel coronavirus, now named severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), from the affected patients. Highly sensitive and specific laboratory diagnostics are important for controlling the rapidly evolving SARS-CoV-2-associated coronavirus disease 2019 (COVID-19) epidemic. In this study, we developed and compared the performance of three novel real-time reverse transcription-PCR (RT-PCR) assays targeting the RNA-dependent RNA polymerase (RdRp)/helicase (Hel), spike (S), and nucleocapsid (N) genes of SARS-CoV-2 with that of the reported RdRp-P2 assay, which is used in >30 European laboratories. Among the three novel assays, the COVID-19-RdRp/Hel assay had the lowest limit of detection in vitro (1.8 50% tissue culture infective doses [TCID50]/ml with genomic RNA and 11.2 RNA copies/reaction with in vitro RNA transcripts). Among 273 specimens from 15 patients with laboratory-confirmed COVID-19 in Hong Kong, 77 (28.2%) were positive by both the COVID-19-RdRp/Hel and RdRp-P2 assays. The COVID-19-RdRp/Hel assay was positive for an additional 42 RdRp-P2-negative specimens (119/273 [43.6%] versus 77/273 [28.2%]; P < 0.001), including 29/120 (24.2%) respiratory tract specimens and 13/153 (8.5%) non-respiratory tract specimens. The mean viral load of these specimens was 3.21 × 104 RNA copies/ml (range, 2.21 × 102 to 4.71 × 105 RNA copies/ml). The COVID-19-RdRp/Hel assay did not cross-react with other human-pathogenic coronaviruses and respiratory pathogens in cell culture and clinical specimens, whereas the RdRp-P2 assay cross-reacted with SARS-CoV in cell culture. The highly sensitive and specific COVID-19-RdRp/Hel assay may help to improve the laboratory diagnosis of COVID-19.


Assuntos
Betacoronavirus/isolamento & purificação , Técnicas de Laboratório Clínico , Infecções por Coronavirus/diagnóstico , Pneumonia Viral/diagnóstico , Reação em Cadeia da Polimerase Via Transcriptase Reversa/normas , Proteínas Virais/genética , Adulto , Idoso , Animais , COVID-19 , Teste para COVID-19 , Vacinas contra COVID-19 , China , Chlorocebus aethiops , Infecções por Coronavirus/virologia , Feminino , Humanos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade , Técnicas de Diagnóstico Molecular/normas , Pandemias , Pneumonia Viral/virologia , SARS-CoV-2 , Sensibilidade e Especificidade , Células Vero
17.
Biomed Res Int ; 2019: 5715180, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31687393

RESUMO

Several commercial PCR kits are available for detection of herpes simplex virus (HSV) and varicella zoster virus (VZV), but the test performance of one CE-marked in vitro diagnostic kit-RealStar® alpha Herpesvirus PCR Kit-has not been well studied. This study evaluated the performance of RealStar® alpha Herpesvirus PCR Kit 1.0 on the LightCycler® 480 Instrument II for detection and differentiation of HSV-1, HSV-2, and VZV in human clinical specimens. We evaluated the analytical sensitivity of the RealStar® and in-house multiplex real-time PCR assays using serial dilutions of nucleic acids extracted from clinical specimens. The analytical sensitivity of the RealStar® assay was 10, 32, and 100 copies/reaction for HSV-1, HSV-2, and VZV, respectively, which was slightly higher than that of the in-house multiplex real-time PCR assay. Reproducibility of the cycle threshold (Cp) values for each viral target was satisfactory with the intra- and interassay coefficient of variation values below 5% for both assays. One-hundred and fifty-three clinical specimens and 15 proficiency testing samples were used to evaluate the diagnostic performance of RealStar® alpha Herpesvirus PCR Kit against the in-house multiplex real-time PCR assay. The RealStar® assay showed 100% sensitivity and specificity when compared to the in-house assay. Cp values of the RealStar® and in-house assays showed excellent correlation. RealStar® alpha Herpesvirus PCR is a sensitive, specific, and reliable assay for the detection of HSV-1, HSV-2, and VZV, with less extensive verification requirements compared to a laboratory developed assay.


Assuntos
Herpesvirus Humano 1/genética , Herpesvirus Humano 2/genética , Herpesvirus Humano 3/genética , Reação em Cadeia da Polimerase Multiplex/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos , DNA Viral/genética , Herpes Simples/virologia , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Open Forum Infect Dis ; 6(8): ofz329, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31660385

RESUMO

BACKGROUND: Transmission of human hepegivirus 1 (HHpgV-1), a novel human pegivirus, is closely associated with hepatitis C virus (HCV). The impact of HHpgV-1 viremia on HCV infection is unknown. This study aimed to (a) evaluate the impact of HHpgV-1 viremia on HCV viral load and liver injury and (b) elucidate the clinical and molecular epidemiology of HHpgV-1 infection. METHODS: Individuals with HHpgV-1 viremia (cases) were identified by screening plasma from 655 HCV-infected adults. HHpgV-1 isolates were sequenced for phylogenetic analysis, and viral load was quantified. Cases were age- and sex-matched to HCV-infected individuals without HHpgV-1 viremia (controls) in a 1:3 ratio. A retrospective case-control analysis was performed to identify differences in HCV viral load and parameters of liver injury. RESULTS: Among HCV-infected adults, 16/655 (2.4%) had HHpgV-1 viremia. Risk groups for HHpgV-1 infection included intravenous drug users, blood product recipients, tattoo recipients, and men who have sex with men. Viral sequences clustered into 2 distinct HHpgV-1 genogroups. Cases had a higher mean HCV viral load than controls, with difference between means of 0.58 log10 IU/mL (P = .009). Cases were more likely to have an HCV viral load >5 log10 IU/mL (P = .028). Multiple regression demonstrated the impact of HHpgV-1 viral load and infection status on HCV viral load. HHpgV-1 infection was not associated with higher liver function tests, fibrosis scores, or imaging abnormalities. CONCLUSIONS: HHpgV-1 viremia is associated with a higher HCV viral load in co-infected patients. HHpgV-1 infection does not affect progression of HCV-related liver disease.

19.
Emerg Infect Dis ; 25(3): 425-433, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30789146

RESUMO

Hepatitis E virus (HEV) genotype 4 (HEV-4) is an emerging cause of acute hepatitis in China. Less is known about the clinical characteristics and natural history of HEV-4 than HEV genotype 3 infections in immunocompromised patients. We report transmission of HEV-4 from a deceased organ donor to 5 transplant recipients. The donor had been viremic but HEV IgM and IgG seronegative, and liver function test results were within reference ranges. After a mean of 52 days after transplantation, hepatitis developed in all 5 recipients; in the liver graft recipient, disease was severe and with progressive portal hypertension. Despite reduced immunosuppression, all HEV-4 infections progressed to persistent hepatitis. Four patients received ribavirin and showed evidence of response after 2 months. This study highlights the role of organ donation in HEV transmission, provides additional data on the natural history of HEV-4 infection, and points out differences between genotype 3 and 4 infections in immunocompromised patients.


Assuntos
Genótipo , Vírus da Hepatite E/genética , Hepatite E/epidemiologia , Hepatite E/virologia , Doadores de Tecidos , Adulto , Idoso , Criança , Surtos de Doenças , Feminino , Hepatite E/diagnóstico , Hepatite E/história , Vírus da Hepatite E/classificação , História do Século XXI , Hong Kong/epidemiologia , Humanos , Imuno-Histoquímica , Masculino , Pessoa de Meia-Idade , Tipagem Molecular , Transplante de Órgãos , Filogenia , Análise de Sequência de DNA , Testes Sorológicos
20.
Emerg Infect Dis ; 24(12): 2241-2250, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30457530

RESUMO

All hepatitis E virus (HEV) variants reported to infect humans belong to the species Orthohepevirus A (HEV-A). The zoonotic potential of the species Orthohepevirus C (HEV-C), which circulates in rats and is highly divergent from HEV-A, is unknown. We report a liver transplant recipient with hepatitis caused by HEV-C infection. We detected HEV-C RNA in multiple clinical samples and HEV-C antigen in the liver. The complete genome of the HEV-C isolate had 93.7% nt similarity to an HEV-C strain from Vietnam. The patient had preexisting HEV antibodies, which were not protective against HEV-C infection. Ribavirin was an effective treatment, resulting in resolution of hepatitis and clearance of HEV-C viremia. Testing for this zoonotic virus should be performed for immunocompromised and immunocompetent patients with unexplained hepatitis because routine hepatitis E diagnostic tests may miss HEV-C infection. HEV-C is also a potential threat to the blood product supply.


Assuntos
Vírus da Hepatite E , Hepatite E/epidemiologia , Hepatite E/etiologia , Transplante de Fígado/efeitos adversos , Transplantados , Animais , Antivirais/uso terapêutico , Genoma Viral , Genômica/métodos , Hepatite E/tratamento farmacológico , Hepatite E/virologia , Vírus da Hepatite E/classificação , Vírus da Hepatite E/genética , Humanos , Masculino , Pessoa de Meia-Idade , Fases de Leitura Aberta , Ratos , Resultado do Tratamento , Carga Viral , Sequenciamento Completo do Genoma
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA