Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Vet World ; 17(1): 171-178, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38406373

RESUMO

Background and Aim: African swine fever (ASF) causes disease in pigs with up to 100% mortality rates. There is no effective vaccine to protect against it. This study aimed to perform in silico docking of ASF virus (ASFV) pNP868R protein with potential flavonoid ligands to identify ligands that interfere with mRNA cap formation. Materials and Methods: The ASFV pNP868R protein was tested with hyperoside, isoquercetin, quercetin, and quercitrin in this in silico simulation. ASFV pNP868R protein was extracted from the Research Collaboration for Structural Bioinformatics Protein Data Bank (RCSB PDB) database with PDB ID 7D8U (https://www.rcsb.org/structure/7D8U). Standard ligands were separated from proteins using UCSF Chimera 1.13. The standard ligand was redocked to protein using AutoDockTools 1.5.6 with the AutoDock4 method for validation. In the docking process, the grid box size was 40 × 40 × 40 Å3 with x, y, and z coordinates of 16.433, -43.826, and -9.496, respectively. The molecular docking process of the proposed ligand-protein complex can proceed if the standard ligand position is not significantly different from its original position in the viral protein's pocket. The root mean square deviation (RMSD), root mean square fluctuation (RMSF), and radius of gyration (RoG) of the hyperoside with the lowest energy binding need to be analyzed with molecular dynamics using Groningen machine for chemical simulation 5.1.1. Results: Molecular docking and dynamic simulation revealed that hyperoside had the most stable and compact binding to the pNP868R protein. Hyperoside binds to the protein at the minimum energy of -9.07 KJ/mol. The RMSD, RMSF, and RoG values of 0.281 nm, 0.2 nm, and 2.175 nm, respectively, indicate the stability and compactness of this binding. Conclusion: Hyperoside is the most likely antiviral candidate to bind to the pNP868R protein in silico. Therefore, it is necessary to test whether this flavonoid can inhibit mRNA capping in vitro and elicit the host immune response against uncapped viral mRNA.

2.
Sci Adv ; 9(1): eabq5273, 2023 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-36608124

RESUMO

Mastering nuclear fusion, which is an abundant, safe, and environmentally competitive energy, is a great challenge for humanity. Tokamak represents one of the most promising paths toward controlled fusion. Obtaining a high-performance, steady-state, and long-pulse plasma regime remains a critical issue. Recently, a big breakthrough in steady-state operation was made on the Experimental Advanced Superconducting Tokamak (EAST). A steady-state plasma with a world-record pulse length of 1056 s was obtained, where the density and the divertor peak heat flux were well controlled, with no core impurity accumulation, and a new high-confinement and self-organizing regime (Super I-mode = I-mode + e-ITB) was discovered and demonstrated. These achievements contribute to the integration of fusion plasma technology and physics, which is essential to operate next-step devices.

3.
Rev Sci Instrum ; 92(5): 053514, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243270

RESUMO

A five-chord interferometer based on terahertz solid state sources has been successfully installed on the Keda Torus eXperiment (KTX), a reversed field pinch machine. The optical design has been carefully optimized for the uniform distribution of beam light to fully use the limited power source (∼2 mW). By setting the telescopic mirror unit, the beam waist is located in the center of the vacuum vessel and its diameter is in the range of the Rayleigh length. The beam width across the plasma area is improved to ∼20 mm to minimize crosstalk and beam energy loss. After careful beam alignment, the phase noise for each channel can reach 0.004π. The radial profiles of electron density on the KTX are inverted, and density fluctuation associated with instabilities is shown based on the forward-scattering signals.

4.
Rev Sci Instrum ; 89(10): 10H119, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399952

RESUMO

Electron Cyclotron Emission Imaging (ECEI) is a diagnostic system which measures 2-D electron temperature profiles with high spatial-temporal resolution. Usually only the normalized electron temperature fluctuations are utilized to investigate the magnetohydrodynamics modes due to the difficulties of ECEI calibration. In this paper, we developed a self-dependent calibration method for 24 × 16 channel high-resolution ECEI on the Experimental Advanced Superconducting Tokamak. The technique of shape matching is applied to solve for the matrix of the calibration coefficients. The calibrated area is further expanded to an occupation ratio of 88% observation area by utilizing the features of sawtooth crash. The result is self-consistent and consistent with calibrated 1D ECE measurement.

5.
Rev Sci Instrum ; 88(9): 093513, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28964207

RESUMO

A system for electromagnetic measurements was designed and installed on the Keda Torus eXperiment (KTX) reversed field pinch device last year. Although the unique double-C structure of the KTX, which allows the machine to be opened easily without disassembling the poloidal field windings, makes the convenient replacement and modification of the internal inductive coils possible, it can present difficulties in the design of flux coils and magnetic probes at the two vertical gaps. Moreover, the KTX has a composite shell consisting of a 6 mm stainless steel vacuum chamber and a 1.5 mm copper shell, which results in limited space for the installation of saddle sensors. Therefore, the double-C structure and composite shell should be considered, especially during the design and installation of the electromagnetic diagnostic system (EDS). The inner surface of the vacuum vessel includes two types of probes. One type is for the measurement of the global plasma parameters, and the other type is for studying the local behavior of the plasma and operating the new saddle coils. In addition, the probes on the outer surface of the composite shell are used for measurements of eddy currents. Finally, saddle sensors for radial field measurements for feedback control were installed between the conducting shell and the vacuum vessel. The entire system includes approximately 1100 magnetic probes, 14 flux coils, 4×26×2 saddle sensors, and 16 Rogowski coils. Considering the large number of probes and limited space available in the vacuum vessel, the miniaturization of the probes and optimization of the probe distribution are necessary. In addition, accurate calibration and careful mounting of the probes are also required. The frequency response of the designed magnetic probes is up to 200 kHz, and the resolution is 1 G. The EDS, being spherical and of high precision, is one of the most basic and effective diagnostic tools of the KTX and meets the demands imposed by requirements on basic machine operating information and future studies.

6.
Rev Sci Instrum ; 87(11): 113503, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910585

RESUMO

In a reversed field pinch device, the conductive shell is placed as close as possible to the plasma so as to balance the plasma during discharge. Plasma instabilities such as the resistive wall mode and certain tearing modes, which restrain the plasma high parameter operation, respond closely with conditions in the wall, in essence the eddy current present. Also, the effect of eddy currents induced by the external coils cannot be ignored when active control is applied to control instabilities. One diagnostic tool, an eddy current probe array, detects the eddy current in the composite shell. Magnetic probes measuring differences between the inner and outer magnetic fields enable estimates of the amplitude and angle of these eddy currents. Along with measurements of currents through the copper bolts connecting the poloidal shield copper shells, we can obtain the eddy currents over the entire shell. Magnetic field and eddy current resolutions approach 2 G and 6 A, respectively. Additionally, the vortex electric field can be obtained by eddy current probes. As the conductivity of the composite shell is high, the eddy current probe array is very sensitive to the electric field and has a resolution of 0.2 mV/cm. In a bench test experiment using a 1/4 vacuum vessel, measurements of the induced eddy currents are compared with simulation results based on a 3D electromagnetic model. The preliminary data of the eddy currents have been detected during discharges in a Keda Torus eXperiment device. The typical value of toroidal and poloidal eddy currents across the magnetic probe coverage rectangular area could reach 3.0 kA and 1.3 kA, respectively.

7.
Rev Sci Instrum ; 87(11): 11E122, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910668

RESUMO

A compact and lightweight support platform has been used as a holder for the interferometer system on the Keda Torus eXperiment (KTX), which is a reversed field pinch device. The vibration caused by the interaction between the time-varying magnetic field and the induced current driven in the metal optical components has been measured and, following comparison with the mechanical vibration of the KTX device and the refraction effect of the ambient turbulent air flow, has been identified as the primary vibration source in this case. To eliminate this electromagnetic disturbance, nonmetallic epoxy resin has been selected as the material for the support platform and the commercially available metal optical mounts are replaced. Following these optimization steps and mechanical reinforcements, the stability of the interferometer platform has improved significantly. The phase shift caused by the vibration has been reduced to the level of background noise.

8.
Rev Sci Instrum ; 85(11): 11D828, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430241

RESUMO

A solid-state source based terahertz (THz) interferometer diagnostic system has been designed and characterized for the Keda Torus eXperiment (KTX). The THz interferometer utilizes the planar diodes based frequency multiplier (X48) to provide the probing beam at fixed frequency 0.650 THz, and local oscillator is provided by an independent solid-state diode source with tunable frequency (0.650 THz +/- 10 MHz). Both solid-state sources have approximately 1 mW power. The planar-diode mixers optimized for high sensitivity, ∼750 mV/mW, are used in the heterodyne detection system, which permits multichannel interferometer on KTX with a low phase noise. A sensitivity of ⟨nel⟩min = 4.5 × 10(16) m(-2) and a temporal resolution of 0.2 µs have been achieved during the initial bench test.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA