Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Insects ; 15(10)2024 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-39452311

RESUMO

In addition to blood pathogen transmission, insects of the order Diptera affect livestock through visual and contact harassment; blood-feeders are responsible for painful bites and blood despoliation, generating behavioral modifications, anemia, and production losses. Knowledge of their economic impact is a basis for cost-effective control. Here, we measured the global impact of diptera insects by comparing two batches of six feeder cattle, one in the open air and the other protected by a mosquito net. The analytical data were insect density in the open air and, for feeder cattle, tail flick counts, hematocrit values (Ht), feed intake, feed conversion ratio (FCR), and live body weight gain (LBWG). Over a period of five months, the results showed significant losses in the LBWG of cattle exposed to insects, estimated at 8.0 ± 1.5 kg/month [2.7; 13.3], with a total loss reaching 40.0 ± 5.5 kg/head. Main diurnal insects were Stomoxys spp. and Musca crassirostris. There was a strong correlation between fly density and diurnal tail flicks. Night trapping and tail flicks showed a potentially important role of mosquitoes to be further explored. The Ht levels of exposed animals were 3-4% lower than those of controls. FCRs indicated that exposed animals needed 33% more dry matter intake/kg of LBWG. An economic assessment showed that dipterans were responsible for a 10-11% loss in LBWG during the main growing period of feeder cattle (10-15 months). A feedlot of 100 calves would register a total loss of USD 16,000 within 5 months, which appears to be an unexpectedly huge loss caused by dipterans. Investing part of this money into fly control would probably be beneficial.

2.
Science ; 385(6714): 1196-1205, 2024 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-39264997

RESUMO

Climate change is increasingly predisposing polar regions to large landslides. Tsunamigenic landslides have occurred recently in Greenland (Kalaallit Nunaat), but none have been reported from the eastern fjords. In September 2023, we detected the start of a 9-day-long, global 10.88-millihertz (92-second) monochromatic very-long-period (VLP) seismic signal, originating from East Greenland. In this study, we demonstrate how this event started with a glacial thinning-induced rock-ice avalanche of 25 × 106 cubic meters plunging into Dickson Fjord, triggering a 200-meter-high tsunami. Simulations show that the tsunami stabilized into a 7-meter-high long-duration seiche with a frequency (11.45 millihertz) and slow amplitude decay that were nearly identical to the seismic signal. An oscillating, fjord-transverse single force with a maximum amplitude of 5 × 1011 newtons reproduced the seismic amplitudes and their radiation pattern relative to the fjord, demonstrating how a seiche directly caused the 9-day-long seismic signal. Our findings highlight how climate change is causing cascading, hazardous feedbacks between the cryosphere, hydrosphere, and lithosphere.

3.
J Med Imaging (Bellingham) ; 10(2): 024001, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36875637

RESUMO

Purpose: Segmentation of vascular structures in preoperative computed tomography (CT) is a preliminary step for computer-assisted endovascular navigation. It is a challenging issue when contrast medium enhancement is reduced or impossible, as in the case of endovascular abdominal aneurysm repair for patients with severe renal impairment. In non-contrast-enhanced CTs, the segmentation tasks are currently hampered by the problems of low contrast, similar topological form, and size imbalance. To tackle these problems, we propose a novel fully automatic approach based on convolutional neural network. Approach: The proposed method is implemented by fusing the features from different dimensions by three kinds of mechanisms, i.e., channel concatenation, dense connection, and spatial interpolation. The fusion mechanisms are regarded as the enhancement of features in non-contrast CTs where the boundary of aorta is ambiguous. Results: All of the networks are validated by three-fold cross-validation on our dataset of non-contrast CTs, which contains 5749 slices in total from 30 individual patients. Our methods achieve a Dice score of 88.7% as the overall performance, which is better than the results reported in the related works. Conclusions: The analysis indicates that our methods yield a competitive performance by overcoming the above-mentioned problems in most general cases. Further, experiments on our non-contrast CTs demonstrate the superiority of the proposed methods, especially in low-contrast, similar-shaped, and extreme-sized cases.

4.
Int J Numer Method Biomed Eng ; 39(3): e3685, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36645263

RESUMO

The purpose of this work is to present a patient-specific (PS) modeling approach for simulating percutaneous transluminal angioplasty (PTA) endovascular treatment and assessing the balloon sizing influence on short-term outcomes in peripheral arteries, i.e. without stent implantation. Two 3D PS stenosed femoral artery models, one with a dominant calcified atherosclerosis while the other with a lipidic plaque, were generated from pre-operative computed tomography angiography images. Elastoplastic constitutive laws were implemented within the plaque and artery models. Implicit finite element method (FEM) was used to simulate the balloon inflation and deflation for different sizings. Besides vessel strains, results were mainly evaluated in terms of the elastic recoil ratio (ERR) and lumen gain ratio (LGR) attained immediately after PTA. Higher LGR values were shown within the stenosed region of the lipidic patient. Simulated results also showed a direct and quantified correlation between balloon sizing and LGR and ERR for both patients after PTA, with a more significant influence on the lumen gain. The max principal strain values in the outer arterial wall increased at higher balloon sizes during inflation as well, with higher rates of increase when the plaque was calcified. Results show that our model could serve in finding a compromise for each stenosis type: maximizing the achieved lumen gain after PTA, but at the same time without damaging the arterial tissue. The proposed methodology can serve as a step toward a clinical decision support system to improve angioplasty balloon sizing selection prior to the surgery.


Assuntos
Angioplastia com Balão , Angioplastia , Humanos , Análise de Elementos Finitos , Angioplastia/métodos , Artéria Femoral/cirurgia , Constrição Patológica , Stents , Resultado do Tratamento
5.
Sci Total Environ ; 859(Pt 1): 160110, 2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36370780

RESUMO

On December 15th 1952, at approximately 14:00 local time a mass of 5.9 × 106 m3 of permafrozen talus deposits failed in a landslide close to the Niiortuut mountain on the south coast of the Nuussuaq peninsula, central West Greenland. Between 1.8 and 4.5 × 106 m3 of the material entered the sea and generated a tsunami that propagated through the Vaigat strait (Sullorsuaq). Here we describe this catastrophic event for the first time by analysis of historical material supplemented by recent fieldwork and discuss the implications for the state of contemporary permafrozen slopes. The tsunami killed a fisherman working on the shore of southern Nuussuaq, 10 km south-east of the landslide. In the mining town of Qullissat, 30 km south of the landslide, it had a runup height of 2.2-2.7 m and caused minor material damage. Morphological evidence show that the basal surface of rupture was 80 m inside the permafrost cemented talus slope, whose degradation was a dynamic conditioning factor for the landslide. The 1952 Niiortuut landslide is the first historically recorded event of permafrost degradation induced landslide-tsunamis in the Arctic. We infer that the landslide and its cascading consequences occurred due to the early-twentieth century warming that started in the late 1910's in the Arctic. Warming is now increasingly affecting this region, as shown by an enhanced recent landslide activity.


Assuntos
Desastres , Deslizamentos de Terra , Pergelissolo , Tsunamis , Regiões Árticas , Desastres/história , Groenlândia , Deslizamentos de Terra/história , Tsunamis/história , Humanos , Mudança Climática
6.
Insects ; 13(7)2022 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-35886792

RESUMO

Hematophagous flies are a pest for livestock; their direct impact reduces productivity, and they are vectors of parasites, bacteria and viruses. Their control using insecticides is inefficient and highly polluting. The validation of new control tools requires efficacy and cost-effectiveness evaluation. The quantification of hematophagous insects' impact in livestock is a challenging prerequisite. Tail flicks counts can reliably evaluate fly-burden; however, visual records are tedious and time-consuming. In the present study, automation of tail flick counts was made through the use of pedometers attached to the tail, in two groups of feeder cattle. Group A was kept in a pen under the protection of a mosquito net, and Group B was kept in an open-air pen. The fly density of Group B was evaluated using fly traps. The apparent density per trap ranged from 130 to 1700 in the study. The mean pedometer records per 24 h ranged from 957+/-58 bits in Group A to 11,138+/-705 bits in Group B. The night/day records observed in Group A (200/800 bits) were drastically increased in Group B (1000-4000/4000-14,000 bits) and variable along seasons. A very high correlation was observed between fly density and visual records or pedometer records (PR). Two-hour PRs proved to be a reliable predictive tool for fly density. Moreover, the pedometers revealed an unsuspected but significant nuisance of mosquitoes, which should be thoroughly investigated.

7.
Int J Comput Assist Radiol Surg ; 17(7): 1281-1288, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35486303

RESUMO

PURPOSE: Endovascular revascularization is becoming the established first-line treatment of peripheral artery disease (PAD). Ultrasound (US) imaging is used pre-operatively to make the first diagnosis and is often followed by a CT angiography (CTA). US provides a non-invasive and non-ionizing method for the visualization of arteries and lesion(s). This paper proposes to generate a 3D stretched reconstruction of the femoral artery from a sequence of 2D US B-mode frames. METHODS: The proposed method is solely image-based. A Mask-RCNN is used to segment the femoral artery on the 2D US frames. In-plane registration is achieved by aligning the artery segmentation masks. Subsequently, a convolutional neural network (CNN) predicts the out-of-plane translation. After processing all input frames and re-sampling the volume according to the vessel's centerline, the whole femoral artery can be visualized on a single slice of the resulting stretched view. RESULTS: 111 tracked US sequences of the left or right femoral arteries have been acquired on 18 healthy volunteers. fivefold cross-validation was used to validate our method and achieve an absolute mean error of 0.28 ± 0.28 mm and a median drift error of 8.98%. CONCLUSION: This study demonstrates the feasibility of freehand US stretched reconstruction following a deep learning strategy for imaging the femoral artery. Stretched views are generated and can give rich diagnosis information in the pre-operative planning of PAD procedures. This visualization could replace traditional 3D imaging in the pre-operative planning process, and during the pre-operative diagnosis phase, to identify, locate, and size stenosis/thrombosis lesions.


Assuntos
Imageamento Tridimensional , Doença Arterial Periférica , Artérias , Angiografia por Tomografia Computadorizada , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Redes Neurais de Computação , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/cirurgia , Ultrassonografia/métodos
8.
Int J Numer Method Biomed Eng ; 37(8): e3499, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33998779

RESUMO

In this work we propose a generic modeling approach for simulating percutaneous transluminal angioplasty (PTA) endovascular treatment, and evaluating the influence of balloon design, plaque composition, and balloon sizing on acute post-procedural outcomes right after PTA, without stent implantation. Clinically-used PTA balloons were classified into two categories according to their compliance characteristics, and were modeled correspondingly. Self-defined elastoplastic constitutive laws were implemented within the plaque and artery models, after calibration based on experimental and clinical data. Finite element method (FEM) implicit solver was used to simulate balloon inflation and deflation. Besides balloon profile at max inflation, results are mainly assessed in terms of the elastic recoil ratio (ERR) and lumen gain ratio (LGR) obtained immediately after PTA. No variations in ERR nor LGR values were detected when the balloon design changed, despite the differences observed in their profile at max inflation. Moreover, LGR and ERR inversely varied with the augmentation of calcification level within the plaque (-11% vs. +4% respectively, from fully lipidic to fully calcified plaque). Furthermore, results showed a direct correlation between balloon sizing and LGR and ERR, with noticeably higher rates of change for LGR (+18% and +2% for LGR and ERR respectively for a calcified plaque and a balloon pressure increasing from 10 to 14 atm). However a larger LGR comes with a higher risk of arterial rupture. This proposed methodology opens the way for evaluation of angioplasty balloon selections towards clinical procedure optimization.


Assuntos
Angioplastia com Balão , Placa Aterosclerótica , Angioplastia , Análise de Elementos Finitos , Humanos , Placa Aterosclerótica/terapia , Resultado do Tratamento
9.
Int J Numer Method Biomed Eng ; 37(1): e03409, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33098246

RESUMO

Fenestrated endovascular aneurism repair (FEVAR) is a minimally invasive technique, and its success depends on the adequacy of the correspondence between the visceral arteries ostia and position of the fenestrations of the stent graft (SG) during its deployment in juxtarenal aneurisms. However, the fenestration position is generally determined from a preoperative computerised tomography (CT) scan, without considering the vascular deformation induced by the insertion of the endovascular tools. Catheterisation difficulties may occur during clinical procedures. Accordingly, the objective of this work is to present an initial proof of concept aimed at anticipating and optimising the position of the fenestrations, while considering the vascular deformation induced by the insertion of the endovascular tools. The proposed method relies on the finite element method to simulate the SG deployment in a vascular structure (VS), and considers the vascular deformation induced by the tools. After determining the optimal simulation parameters for a patient-specific case, the robustness of the method is demonstrated on six other representative anatomies. The simulated SG is also compared with post-deployment CT observations, and demonstrates good adequacy. The results show that the numerically corrected fenestration positions, as determined from the simulated results following the insertion of the endovascular tools, deviate from those of the standard plan (as determined from the preoperative CT scan). This indicates that the SG-VS adequacy could be improved via simulation-based planning, to anticipate potential catheterisation difficulties.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Humanos , Desenho de Prótese , Stents , Resultado do Tratamento
10.
Ann Vasc Surg ; 71: 273-279, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32890647

RESUMO

BACKGROUND: Fusion imaging makes it possible to improve endovascular procedures and is mainly used in hybrid rooms for aortic procedures. The objective of this study was to evaluate the feasibility of fusion imaging for femoropopliteal endovascular procedures with a mobile flat plane sensor and dedicated software to assist endovascular navigation. MATERIALS AND METHODS: Between May and December 2017, 41 patients requiring femoropopliteal endovascular revascularization were included. Interventions were carried out in a conventional surgical room equipped with a mobile plane sensor (Cios Alpha, Siemens). The numerical video stream was transmitted to an angionavigation station (EndoNaut (EN), Therenva). The software created an osseous and arterial panorama of the treated limb from the angiographies carried out at the beginning of procedure. After each displacement of the table, the software relocated the current image on the osseous panorama, with 2D-2D resetting, and amalgamated the mask of the arterial panorama. The success rates of creation of osseous and arterial panorama and the success of relocation were evaluated. The data concerning irradiation, the volume of contrast (VC) injected, and operative times were recorded. RESULTS: Osseous panoramas could be automatically generated for the 41 procedures, without manual adjustment in 33 cases (80.5%). About 35 relocations based on a 2D-2D resetting could be obtained in the 41 procedures, with a success rate of 85%. The causes of failure were a change in table height or arch angulation. The average duration of intervention was 74.5 min. The irradiation parameters were duration of fluoroscopy 17.8 ± 13.1 min, air kerma 80.5 ± 68.4 mGy, and dose area product 2140 ± 1599 µGy m2. The average VC was 24.5 ± 14 mL. CONCLUSIONS: This preliminary study showed that fusion imaging is possible in a nonhybrid room for peripheral procedures. Imagery of mobile C-arms can be improved for femoropopliteal endovascular procedures without heavy equipment. These imagery tools bring an operative comfort and could probably reduce irradiation and the injected VC. The clinical benefit must be evaluated in more patients in a randomized comparative study with a rigorous methodology.


Assuntos
Angiografia/instrumentação , Procedimentos Endovasculares/instrumentação , Artéria Femoral/diagnóstico por imagem , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Artéria Poplítea/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Intervencionista/instrumentação , Terapia Assistida por Computador/instrumentação , Idoso , Idoso de 80 Anos ou mais , Procedimentos Endovasculares/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Salas Cirúrgicas , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Radiografia Intervencionista/efeitos adversos , Software , Fatores de Tempo , Resultado do Tratamento
11.
Polymers (Basel) ; 12(10)2020 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-33050464

RESUMO

The objective of this work is to study the influence of the ratio between the elastomer (EPDM) phase and the thermoplastic phase (PP) in thermoplastic vulcanizates (TPVs) as well as the associated morphology of the compression set of the material. First, from a study of the literature, it is concluded that the rubber phase must be dispersed with a large distribution of the domain size in the thermoplastic phase in order to achieve a high concentration, i.e., a maximal packing fraction close to ~0.80. From this discussion, it is inferred that a certain degree of progress in the crosslinking reaction must be reached when the thermoplastic phase is melted during mixing in order to achieve dispersion of the elastomeric phase in the thermoplastic matrix under maximum stress. In terms of elasticity recovery which is measured from the compression set experiment, it is observed that the crosslinking agent nature (DCP or phenolic resin) has no influence in the case of a TPV compared with a pure crosslinked EPDM system. Then, the TPV morphology and the rubber phase concentration are the first order parameters in the compression set of TPVs. Finally, the addition of carbon black fillers leads to an improvement of the mechanical properties at break for the low PP concentration (20%). However, the localization of carbon black depends on the crosslinking chemistry nature. With radical chemistry by organic peroxide decomposition, carbon black is located at the interface of EPDM and PP acting as a compatibilizer.

12.
Ann Vasc Surg ; 61: 291-298, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31352087

RESUMO

BACKGROUND: During endovascular aneurysm repair (EVAR), complex iliac anatomy is a source of complications such as unintentional coverage of the hypogastric artery. The aim of our study was to evaluate ability to predict coverage of the hypogastric artery using a biomechanical model simulating arterial deformations caused by the delivery system. METHODS: The biomechanical model of deformation has been validated by many publications. The simulations were performed on 38 patients included retrospectively, for a total of 75 iliac arteries used for the study. On the basis of objective measurements, two groups were formed: one with "complex" iliac anatomy (n = 38 iliac arteries) and the other with "simple" iliac anatomy (n = 37 iliac arteries). The simulation enabled measurement of the lengths of the aorta and the iliac arteries once deformed by the device. Coverage of the hypogastric artery was predicted if the deformed renal/iliac bifurcation length (Lpre) was less than the length of the implanted device (Lstent-measured on the postoperative computed tomography [CT]) and nondeformed Lpre was greater than Lstent. RESULTS: Nine (12%) internal iliac arteries were covered unintentionally. Of the coverage attributed to perioperative deformations, 1 case (1.3%) occurred with simple anatomy and 6 (8.0%) with complex anatomy (P = 0.25). All cases of unintentional coverage were predicted by the simulation. The simulation predicted hypogastric coverage in 35 cases (46.7%). There were therefore 26 (34.6%) false positives. The simulation had a sensitivity of 100% and a specificity of 60.6%. On multivariate analysis, the factors significantly predictive of coverage were the iliac tortuosity index (P = 0.02) and the predicted margin between the termination of the graft limb and the origin of the hypogastric artery in nondeformed (P = 0.009) and deformed (P = 0.001) anatomy. CONCLUSIONS: Numerical simulation is a sensitive tool for predicting the risk of hypogastric coverage during EVAR and allows more precise preoperative sizing. Its specificity is liable to be improved by using a larger cohort.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Simulação por Computador , Procedimentos Endovasculares/efeitos adversos , Artéria Ilíaca/fisiopatologia , Modelos Cardiovasculares , Análise Numérica Assistida por Computador , Complicações Pós-Operatórias/etiologia , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Aortografia/métodos , Fenômenos Biomecânicos , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/instrumentação , Feminino , Análise de Elementos Finitos , Humanos , Artéria Ilíaca/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/fisiopatologia , Desenho de Prótese , Fluxo Sanguíneo Regional , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
13.
Landslides ; 16(6): 1121-1140, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31178675

RESUMO

Understanding what controls the travelling distance of large landslides has been the topic of considerable debate. By combining observation and experimental data with depth-averaged continuum modelling of landslides and generated seismic waves, it was empirically observed that lower effective friction had to be taken into account in the models to reproduce the dynamics and runout distance of larger volume landslides. Moreover, such simulation and observation results are compatible with a friction weakening with velocity as observed in earthquake mechanics. We investigate here as to whether similar empirical reduced friction should be put into discrete element models (DEM) to reproduce observed runout of large landslides on Earth and on Mars. First we show that, in the investigated parameter range and for a given volume, the runout distance simulated by 3D DEM is not much affected by the number (i.e. size) of grains once this number attains ~ 8000. We then calibrate the model on laboratory experiments and simulate other experiments of granular flows on inclined planes, making it possible for the first time to reproduce the observed effect of initial volume and aspect ratio on runout distances. In particular, the normalised runout distance starts to depend on the volume involved only above a critical slope angle > 16-19°, as observed experimentally. Finally, based on field data (volume, topography, deposit), we simulate a series of landslides on simplified inclined topography. The empirical friction coefficient, calibrated to reproduce the observed runout for each landslide, is shown to decrease with increasing landslide volume (or velocity), going down to values as low as 0.1-0.2. No distinguishable difference is observed between the behaviour of terrestrial and Martian landslides.

14.
Sci Adv ; 5(3): eaav7710, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30944863

RESUMO

Mars is dry today, but numerous precipitation-fed paleo-rivers are found across the planet's surface. These rivers' existence is a challenge to models of planetary climate evolution. We report results indicating that, for a given catchment area, rivers on Mars were wider than rivers on Earth today. We use the scale (width and wavelength) of Mars paleo-rivers as a proxy for past runoff production. Using multiple methods, we infer that intense runoff production of >(3-20) kg/m2 per day persisted until <3 billion years (Ga) ago and probably <1 Ga ago, and was globally distributed. Therefore, the intense runoff production inferred from the results of the Mars Science Laboratory rover was not a short-lived or local anomaly. Rather, precipitation-fed runoff production was globally distributed, was intense, and persisted intermittently over >1 Ga. Our improved history of Mars' river runoff places new constraints on the unknown mechanism that caused wet climates on Mars.

15.
Ann Vasc Surg ; 55: 166-174, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30092429

RESUMO

BACKGROUND: Fusion imaging is a technique that facilitates endovascular navigation but is only available in hybrid rooms. The goal of this study was to evaluate the feasibility of fusion imaging with a mobile C-arm in a conventional operating room through the use of an angionavigation station. METHODS: From May 2016 to June 2017, the study included all patients who underwent an aortic stent graft procedure in a conventional operating room with a mobile flat-panel detector (Cios Alpha, Siemens) connected to an angionavigation station (EndoNaut, Therenva). The intention was to perform preoperative 3D computerized tomography/perioperative 2D fluoroscopy fusion imaging using an automatic registration process. Registration was considered successful when the software was able to correctly overlay preoperative 3D vascular structures onto the fluoroscopy image. For EVAR, contrast dose, operation time, and fluoroscopy time (FT) were compared with those of a control group drawn from the department's database who underwent a procedure with a C-arm image intensifier. RESULTS: The study included 54 patients, and the procedures performed were 49 EVAR, 2 TEVAR, 2 IBD, and 1 FEVAR. Of the 178 registrations that were initialized, it was possible to use the fusion imaging in 170 cases, that is, a 95.5% success rate. In the EVAR comparison, there were no difference with the control group (n = 103) for FT (21.9 ± 12 vs. 19.5 ± 13 min; P = 0.27), but less contrast agent was used in the group undergoing a procedure with the angionavigation station (42.3 ± 22 mL vs. 81.2 ± 48 mL; P < 0.001), and operation time was shorter (114 ± 44 vs. 140.8 ± 38 min; P < 0.0001). CONCLUSIONS: Fusion imaging is feasible with a mobile C-arm in a conventional operating room and thus represents an alternative to hybrid rooms. Its clinical benefits should be evaluated in a randomized series, but our study already suggests that EVAR procedures might be facilitated with an angionavigation system.


Assuntos
Aneurisma Aórtico/cirurgia , Aortografia/instrumentação , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada/instrumentação , Procedimentos Endovasculares/instrumentação , Radiografia Intervencionista/instrumentação , Cirurgia Assistida por Computador/instrumentação , Tomógrafos Computadorizados , Idoso , Idoso de 80 Anos ou mais , Aneurisma Aórtico/diagnóstico por imagem , Aortografia/efeitos adversos , Angiografia por Tomografia Computadorizada/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Fluoroscopia/instrumentação , Humanos , Masculino , Duração da Cirurgia , Modelagem Computacional Específica para o Paciente , Projetos Piloto , Estudos Prospectivos , Doses de Radiação , Exposição à Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Intervencionista/efeitos adversos , Cirurgia Assistida por Computador/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
16.
Int J Comput Assist Radiol Surg ; 13(7): 997-1007, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29549554

RESUMO

PURPOSE: Interventional endovascular treatment has become the first line of management in the treatment of peripheral artery disease (PAD). However, contrast and radiation exposure continue to limit the feasibility of these procedures. This paper presents a novel hybrid image fusion system for endovascular intervention of PAD. We present two different roadmapping methods from intra- and pre-interventional imaging that can be used either simultaneously or independently, constituting the navigation system. METHODS: The navigation system is decomposed into several steps that can be entirely integrated within the procedure workflow without modifying it to benefit from the roadmapping. First, a 2D panorama of the entire peripheral artery system is automatically created based on a sequence of stepping fluoroscopic images acquired during the intra-interventional diagnosis phase. During the interventional phase, the live image can be synchronized on the panorama to form the basis of the image fusion system. Two types of augmented information are then integrated. First, an angiography panorama is proposed to avoid contrast media re-injection. Information exploiting the pre-interventional computed tomography angiography (CTA) is also brought to the surgeon by means of semiautomatic 3D/2D registration on the 2D panorama. Each step of the workflow was independently validated. RESULTS: Experiments for both the 2D panorama creation and the synchronization processes showed very accurate results (errors of 1.24 and [Formula: see text] mm, respectively), similarly to the registration on the 3D CTA (errors of [Formula: see text] mm), with minimal user interaction and very low computation time. First results of an on-going clinical study highlighted its major clinical added value on intraoperative parameters. CONCLUSION: No image fusion system has been proposed yet for endovascular procedures of PAD in lower extremities. More globally, such a navigation system, combining image fusion from different 2D and 3D image sources, is novel in the field of endovascular procedures.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Procedimentos Endovasculares/métodos , Fluoroscopia/métodos , Imageamento Tridimensional/métodos , Doença Arterial Periférica/terapia , Humanos , Doença Arterial Periférica/diagnóstico por imagem
17.
Int J Comput Assist Radiol Surg ; 12(9): 1501-1510, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28455765

RESUMO

PURPOSE: Abdominal aortic aneurysm (AAA) is a localized, permanent and irreversible enlargement of the artery, with the formation of thrombus into the inner wall of the aneurysm. A precise patient-specific segmentation of the thrombus is useful for both the pre-operative planning to estimate the rupture risk, and for post-operative assessment to monitor the disease evolution. This paper presents a generic approach for 3D segmentation of thrombus from patients suffering from AAA using computed tomography angiography (CTA) scans. METHODS: A fast and versatile thrombus segmentation approach has been developed. It is composed of initial centerline detection and aorta lumen segmentation, an optimized pre-processing stage and the use of a 3D deformable model. The approach has been designed to be very generic and requires minimal user interaction. The proposed method was tested on different datasets with 145 patients overall, including pre- and post-operative CTAs, abdominal aorta and iliac artery sections, different calcification degrees, aneurysm sizes and contrast enhancement qualities. RESULTS: The thrombus segmentation approach showed very accurate results with respect to manual delineations for all datasets ([Formula: see text] and [Formula: see text] for abdominal aorta sections on pre-operative CTA, iliac artery sections on pre-operative CTAs and aorta sections on post-operative CTA, respectively). Experiments on the different patient and image conditions showed that the method was highly versatile, with no significant differences in term of precision. Comparison with the level-set algorithm also demonstrated the superiority of the 3D deformable model. Average processing time was [Formula: see text]. CONCLUSION: We presented a near-automatic and generic thrombus segmentation algorithm applicable to a large variability of patient and imaging conditions. When integrated in an endovascular planning system, our segmentation algorithm shows its compatibility with clinical routine and could be used for pre-operative planning and post-operative assessment of endovascular procedures.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Trombose/diagnóstico por imagem , Algoritmos , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares , Humanos , Modelos Anatômicos , Período Pós-Operatório , Período Pré-Operatório , Trombose/cirurgia
18.
J Vasc Surg ; 65(6): 1830-1838, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28359714

RESUMO

OBJECTIVE: Sac shrinkage is considered a reliable surrogate marker of success after endovascular aneurysm repair (EVAR). Whereas sac shrinkage is the best expected outcome, predictive factors of sac shrinkage remain unclear. The aim of this study was to identify the role of preoperative and postoperative influencing factors of sac reduction after EVAR. METHODS: Online searches across MEDLINE, Embase, and Cochrane Library medical databases were simultaneously performed. Study effects were pooled using a random-effects model, and forest plots were generated for every potential influencing factor. RESULTS: A total of 24 studies with 14,754 patients were included (mean age, 73.4 years; 76% male). At a mean follow-up of 24 months, the pooled shrinkage proportion was 47%. Random-effects meta-analysis revealed that renal impairment (odds ratio [OR], 0.74; 95% confidence interval [CI], 0.57-0.96), type I endoleaks (OR, 0.17; 95% CI, 0.08-0.39), type II endoleaks (OR, 0.21; 95% CI, 0.14-0.33), and combined type I and type II endoleaks (OR, 0.32; 95% CI, 0.22-0.47) were found to prevent sac shrinkage, whereas hypercholesterolemia (OR, 1.24; 95% CI, 1.02-1.51) and smoking (OR, 1.32; 95% CI, 1.17-1.49) have a significant positive impact on sac shrinkage. In addition, there was a trend toward the association between shrinkage and statin therapy (OR, 4.07; 95% CI, 1.02-16.32) and nearly significant negative impacts of coronary artery disease (OR, 0.84; 95% CI, 0.70-1.01), diabetes (OR, 0.79; 95% CI, 0.60-1.04), and sac thrombus (OR, 0.88; 95% CI, 0.77-1.01) on sac shrinkage. CONCLUSIONS: In this large meta-analysis of patients undergoing EVAR, we found that several comorbidity and postoperative factors were associated with postoperative sac shrinkage. These findings may contribute to a better understanding of the shrinkage process of patients undergoing EVAR.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Comorbidade , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Razão de Chances , Indução de Remissão , Fatores de Risco , Resultado do Tratamento
19.
Vascular ; 25(5): 504-513, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28330432

RESUMO

Objectives This study evaluates the effect of stent sizing with CT-scan on the incidence of restenosis in peripheral arterial disease. Methods This retrospective study included 59 patients with 66 arterial lesions who underwent a endovascular procedure for peripheral arterial disease between April 2013 and October 2013. All patients had de novo iliac or femoral lesions, were candidates for an endovascular procedure alone and underwent CTA preoperatively. The stent actually implanted, whose dimensions were chosen on the basis of the operator's experience on an intraoperative 2D angiography, was compared to the "ideal" stent chosen retrospectively on the basis of precise lesion sizing by the preoperative CTA. Planning was considered "discordant" if there was a difference in length of more than 20 mm and/or a difference in diameter of more than 1 mm between the ideal stent and the actual stent. Results For iliac lesions, discordance essentially concerned stent diameter (36.1%), whereas stent length was the main reason for discordance for femoral lesions (36.7%). The median length of follow-up was 18 months (range 6-24). For iliac lesions, freedom from restenosis at 24 months was higher for patients with concordant planning (90% vs. 62.5%, p = 0.045). Most restenoses occurred in the external iliac artery, where there was a tendency towards oversizing of the implanted stent. For femoral lesions, the restenosis-free rate at 24 months was higher for patients with concordant planning (77.8% vs. 50%, p = 0.057). A multivariate analysis was conducted on the prediction of restenosis. Among factors, only discordant planning was found to be a significant predictor of restenosis with an odds ratio of 0.115 (95% confidence interval, 0.02-0.674; p = 0.016). Conclusion The absence of sizing for peripheral lesions engenders a tendency to choose the wrong stent, in particular in terms of diameter in iliac arteries and length in femoral arteries.


Assuntos
Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/instrumentação , Artéria Femoral/diagnóstico por imagem , Artéria Ilíaca/diagnóstico por imagem , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Stents , Idoso , Idoso de 80 Anos ou mais , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Valor Preditivo dos Testes , Desenho de Prótese , Recidiva , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
20.
Ann Vasc Surg ; 43: 258-264, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28300680

RESUMO

BACKGROUND: To report the prevalence of silent brain infarcts (SBI) at magnetic resonance imaging (MRI) before and after surgery for asymptomatic high grade carotid stenosis. METHODS: This is a single center retrospective observational study. Asymptomatic patients who underwent carotid endarterectomy between October 2012 and October 2014 were included. The preoperative assessment included a Doppler and a computed tomographic (CT) scan dating less than 3 months. A neurological examination was performed during the anesthesia consultation and in the 15 days before surgery. An MRI angiography was performed the day before and 3 days after surgery and was analyzed by an independent neuroradiologist. Preoperative analysis focused on the presence of ischemic events at MRI. The type of plaque, the supra aortic trunk lesions, and the quality of the circle of Willis were analyzed using Doppler and CT scanning. Postoperatively, we searched for signs of postoperative ischemic events at MRI. RESULTS: Forty-one patients were included (85.4% of men), and the mean age was 72.4 ± 8.3 years. We noted 7 (17.1%) contralateral stenoses (>50%) and 2 (4.9%) contralateral thromboses, 6 (14.6%) vertebral stenoses, and 7 (17.1%) abnormalities of the circle of Willis. The morphological analysis described 6 unstable plaques including 4 ulcerated, 1 pseudodissection, and 1 intraplaque hemorrhage. Preoperatively, we noted the presence of 21 (51.2%) ischemic lesions including 9 (21.9%) multiple lacunar ischemic events and 12 (29.3%) silent arterial territory infarcts. Eversion was performed for all patients except for 6 (14.6%), for whom a bypass was necessary. No deaths or major complications were observed in the 30 postoperative days. Postoperatively, MRI showed 3 (7.3%) asymptomatic recent ischemic strokes, 1 ipsilateral middle cerebral artery (MCA) stroke, and 2 contralateral (cerebellar and MCA) strokes. CONCLUSIONS: Patients with asymptomatic significant carotid stenosis show many preoperative SBI indicating a significant embolic risk. It is difficult to conclude about intraoperative embolic risk, but we hope that more data could demonstrate the importance of MRI for the preoperative evaluation of carotid plaques and brain parenchyma, to identify high-risk embolic patients.


Assuntos
Infarto Encefálico/diagnóstico por imagem , Estenose das Carótidas/cirurgia , Angiografia por Ressonância Magnética , Acidente Vascular Cerebral/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Doenças Assintomáticas , Infarto Encefálico/epidemiologia , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/epidemiologia , Feminino , França/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prevalência , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/epidemiologia , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler Transcraniana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA