Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 117
Filtrar
1.
Radiology ; 310(2): e232313, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38349238

RESUMO

Background The Eastern Cooperative Oncology Group-American College of Radiology Imaging Network Cancer Research Group multicenter A6702 trial identified an optimal apparent diffusion coefficient (ADC) cutoff to potentially reduce biopsies by 21% without affecting sensitivity. Whether this performance can be achieved in clinical settings has not yet been established. Purpose To validate the performance of point-of-care ADC measurements with the A6702 trial ADC cutoff for reducing unnecessary biopsies in lesions detected at breast MRI. Materials and Methods Consecutive breast MRI examinations performed from May 2015 to January 2019 at a single medical center and showing biopsy-confirmed Breast Imaging Reporting and Data System category 4 or 5 lesions, without ipsilateral cancer, were identified. Point-of-care lesion ADC measurements collected at clinical interpretation were retrospectively evaluated. MRI examinations included axial T2-weighted, diffusion-weighted, and dynamic contrast-enhanced sequences. Sensitivity and biopsy reduction rates were calculated by applying the A6702 optimal (ADC, 1.53 × 10-3 mm2/sec) and alternate conservative (1.68 × 10-3 mm2/sec) cutoffs. Lesion pathologic outcomes were the reference standard. To assess reproducibility, one radiologist repeated ADC measurements, and agreement was summarized using the intraclass correlation coefficient. Results A total of 240 lesions in 201 women (mean age, 49 years ± 13 [SD]) with pathologic outcomes (63 malignant and 177 benign) were included. Applying the optimal ADC cutoff produced an overall biopsy reduction rate of 15.8% (38 of 240 lesions [95% CI: 11.2, 20.9]), with a sensitivity of 92.1% (58 of 63 lesions [95% CI: 82.4, 97.4]; sensitivity was 97.2% [35 of 36 lesions] [95% CI: 82.7, 99.6] for invasive cancers). Results were similar for screening versus diagnostic examinations (P = .92 and .40, respectively). Sensitivity was higher for masses than for nonmass enhancements (NMEs) (100% vs 85.3%; P = .009). Applying the conservative ADC cutoff achieved a sensitivity of 95.2% (60 of 63 lesions [95% CI: 86.7, 99.0]), with a biopsy reduction rate of 10.4% (25 of 240 lesions [95% CI: 6.7, 14.5]). Repeated single-reader measurements showed good agreement with clinical ADCs (intraclass correlation coefficient, 0.72 [95% CI: 0.58, 0.81]). Conclusion This study validated the clinical use of ADC cutoffs to reduce MRI-prompted biopsies by up to 16%, with a suggested tradeoff of lowered sensitivity for in situ and microinvasive disease manifesting as NME. Clinical trial registration no. NCT02022579 © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Honda and Iima in this issue.


Assuntos
Imageamento por Ressonância Magnética , Sistemas Automatizados de Assistência Junto ao Leito , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Biópsia
2.
Radiol Imaging Cancer ; 6(1): e230033, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38180338

RESUMO

Purpose To describe the design, conduct, and results of the Breast Multiparametric MRI for prediction of neoadjuvant chemotherapy Response (BMMR2) challenge. Materials and Methods The BMMR2 computational challenge opened on May 28, 2021, and closed on December 21, 2021. The goal of the challenge was to identify image-based markers derived from multiparametric breast MRI, including diffusion-weighted imaging (DWI) and dynamic contrast-enhanced (DCE) MRI, along with clinical data for predicting pathologic complete response (pCR) following neoadjuvant treatment. Data included 573 breast MRI studies from 191 women (mean age [±SD], 48.9 years ± 10.56) in the I-SPY 2/American College of Radiology Imaging Network (ACRIN) 6698 trial (ClinicalTrials.gov: NCT01042379). The challenge cohort was split into training (60%) and test (40%) sets, with teams blinded to test set pCR outcomes. Prediction performance was evaluated by area under the receiver operating characteristic curve (AUC) and compared with the benchmark established from the ACRIN 6698 primary analysis. Results Eight teams submitted final predictions. Entries from three teams had point estimators of AUC that were higher than the benchmark performance (AUC, 0.782 [95% CI: 0.670, 0.893], with AUCs of 0.803 [95% CI: 0.702, 0.904], 0.838 [95% CI: 0.748, 0.928], and 0.840 [95% CI: 0.748, 0.932]). A variety of approaches were used, ranging from extraction of individual features to deep learning and artificial intelligence methods, incorporating DCE and DWI alone or in combination. Conclusion The BMMR2 challenge identified several models with high predictive performance, which may further expand the value of multiparametric breast MRI as an early marker of treatment response. Clinical trial registration no. NCT01042379 Keywords: MRI, Breast, Tumor Response Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Neoplasias da Mama , Imageamento por Ressonância Magnética Multiparamétrica , Feminino , Humanos , Pessoa de Meia-Idade , Inteligência Artificial , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Imageamento por Ressonância Magnética , Terapia Neoadjuvante , Resposta Patológica Completa , Adulto
3.
AJR Am J Roentgenol ; 222(1): e2329933, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37850579

RESUMO

DWI is a noncontrast MRI technique that measures the diffusion of water molecules within biologic tissue. DWI is increasingly incorporated into routine breast MRI examinations. Currently, the main applications of DWI are breast cancer detection and characterization, prognostication, and prediction of treatment response to neoadjuvant chemotherapy. In addition, DWI is promising as a noncontrast MRI alternative for breast cancer screening. Problems with suboptimal resolution and image quality have restricted the mainstream use of DWI for breast imaging, but these shortcomings are being addressed through several technologic advancements. In this review, we present an up-to-date assessment of the use of DWI for breast cancer imaging, including a summary of the clinical literature and recommendations for future use.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Sensibilidade e Especificidade , Mama
4.
Magn Reson Med ; 91(5): 1803-1821, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38115695

RESUMO

PURPOSE: K trans $$ {K}^{\mathrm{trans}} $$ has often been proposed as a quantitative imaging biomarker for diagnosis, prognosis, and treatment response assessment for various tumors. None of the many software tools for K trans $$ {K}^{\mathrm{trans}} $$ quantification are standardized. The ISMRM Open Science Initiative for Perfusion Imaging-Dynamic Contrast-Enhanced (OSIPI-DCE) challenge was designed to benchmark methods to better help the efforts to standardize K trans $$ {K}^{\mathrm{trans}} $$ measurement. METHODS: A framework was created to evaluate K trans $$ {K}^{\mathrm{trans}} $$ values produced by DCE-MRI analysis pipelines to enable benchmarking. The perfusion MRI community was invited to apply their pipelines for K trans $$ {K}^{\mathrm{trans}} $$ quantification in glioblastoma from clinical and synthetic patients. Submissions were required to include the entrants' K trans $$ {K}^{\mathrm{trans}} $$ values, the applied software, and a standard operating procedure. These were evaluated using the proposed OSIP I gold $$ \mathrm{OSIP}{\mathrm{I}}_{\mathrm{gold}} $$ score defined with accuracy, repeatability, and reproducibility components. RESULTS: Across the 10 received submissions, the OSIP I gold $$ \mathrm{OSIP}{\mathrm{I}}_{\mathrm{gold}} $$ score ranged from 28% to 78% with a 59% median. The accuracy, repeatability, and reproducibility scores ranged from 0.54 to 0.92, 0.64 to 0.86, and 0.65 to 1.00, respectively (0-1 = lowest-highest). Manual arterial input function selection markedly affected the reproducibility and showed greater variability in K trans $$ {K}^{\mathrm{trans}} $$ analysis than automated methods. Furthermore, provision of a detailed standard operating procedure was critical for higher reproducibility. CONCLUSIONS: This study reports results from the OSIPI-DCE challenge and highlights the high inter-software variability within K trans $$ {K}^{\mathrm{trans}} $$ estimation, providing a framework for ongoing benchmarking against the scores presented. Through this challenge, the participating teams were ranked based on the performance of their software tools in the particular setting of this challenge. In a real-world clinical setting, many of these tools may perform differently with different benchmarking methodology.


Assuntos
Meios de Contraste , Imageamento por Ressonância Magnética , Humanos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Software , Algoritmos
5.
Breast Cancer Res ; 25(1): 138, 2023 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-37946201

RESUMO

PURPOSE: To investigate combined MRI and 18F-FDG PET for assessing breast tumor metabolism/perfusion mismatch and predicting pathological response and recurrence-free survival (RFS) in women treated for breast cancer. METHODS: Patients undergoing neoadjuvant chemotherapy (NAC) for locally-advanced breast cancer were imaged at three timepoints (pre, mid, and post-NAC), prior to surgery. Imaging included diffusion-weighted and dynamic contrast-enhanced (DCE-) MRI and quantitative 18F-FDG PET. Tumor imaging measures included apparent diffusion coefficient, peak percent enhancement (PE), peak signal enhancement ratio (SER), functional tumor volume, and washout volume on MRI and standardized uptake value (SUVmax), glucose delivery (K1) and FDG metabolic rate (MRFDG) on PET, with percentage changes from baseline calculated at mid- and post-NAC. Associations of imaging measures with pathological response (residual cancer burden [RCB] 0/I vs. II/III) and RFS were evaluated. RESULTS: Thirty-five patients with stage II/III invasive breast cancer were enrolled in the prospective study (median age: 43, range: 31-66 years, RCB 0/I: N = 11/35, 31%). Baseline imaging metrics were not significantly associated with pathologic response or RFS (p > 0.05). Greater mid-treatment decreases in peak PE, along with greater post-treatment decreases in several DCE-MRI and 18F-FDG PET measures were associated with RCB 0/I after NAC (p < 0.05). Additionally, greater mid- and post-treatment decreases in DCE-MRI (peak SER, washout volume) and 18F-FDG PET (K1) were predictive of prolonged RFS. Mid-treatment decreases in metabolism/perfusion ratios (MRFDG/peak PE, MRFDG/peak SER) were associated with improved RFS. CONCLUSION: Mid-treatment changes in both PET and MRI measures were predictive of RCB status and RFS following NAC. Specifically, our results indicate a complementary relationship between DCE-MRI and 18F-FDG PET metrics and potential value of metabolism/perfusion mismatch as a marker of patient outcome.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Adulto , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Fluordesoxiglucose F18/uso terapêutico , Terapia Neoadjuvante/métodos , Compostos Radiofarmacêuticos/uso terapêutico , Estudos Prospectivos , Resultado do Tratamento , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos
6.
Cancers (Basel) ; 15(17)2023 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-37686613

RESUMO

Dynamic biomarkers that permit the real-time monitoring of the tumor microenvironment response to therapy are an unmet need in breast cancer. Breast magnetic resonance imaging (MRI) has demonstrated value as a predictor of pathologic complete response and may reflect immune cell changes in the tumor microenvironment. The purpose of this pilot study was to investigate the value of breast MRI features as early markers of treatment-induced immune response. Fourteen patients with early HER2+ breast cancer were enrolled in a window-of-opportunity study where a single dose of trastuzumab was administered and both tissue and MRIs were obtained at the pre- and post-treatment stages. Functional diffusion-weighted and dynamic contrast-enhanced MRI tumor measures were compared with tumor-infiltrating lymphocytes (TILs) and RNA immune signature scores. Both the pre-treatment apparent diffusion coefficient (ADC) and the change in peak percent enhancement (DPE) were associated with increased tumor-infiltrating lymphocytes with trastuzumab therapy (r = -0.67 and -0.69, p < 0.01 and p < 0.01, respectively). Low pre-treatment ADC and a greater decrease in PE in response to treatment were also associated with immune-activated tumor microenvironments as defined by RNA immune signatures. Breast MRI features hold promise as biomarkers of early immune response to treatment in HER2+ breast cancer.

7.
Radiology ; 308(2): e230576, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37581498

RESUMO

Background Contrast-enhanced mammography (CEM) and abbreviated breast MRI (ABMRI) are emerging alternatives to standard MRI for supplemental breast cancer screening. Purpose To compare the diagnostic performance of CEM, ABMRI, and standard MRI. Materials and Methods This single-institution, prospective, blinded reader study included female participants referred for breast MRI from January 2018 to June 2021. CEM was performed within 14 days of standard MRI; ABMRI was produced from standard MRI images. Two readers independently interpreted each CEM and ABMRI after a washout period. Examination-level performance metrics calculated were recall rate, cancer detection, and false-positive biopsy recommendation rates per 1000 examinations and sensitivity, specificity, and positive predictive value of biopsy recommendation. Bootstrap and permutation tests were used to calculate 95% CIs and compare modalities. Results Evaluated were 492 paired CEM and ABMRI interpretations from 246 participants (median age, 51 years; IQR, 43-61 years). On 49 MRI scans with lesions recommended for biopsy, nine lesions showed malignant pathology. No differences in ABMRI and standard MRI performance were identified. Compared with standard MRI, CEM demonstrated significantly lower recall rate (14.0% vs 22.8%; difference, -8.7%; 95% CI: -14.0, -3.5), lower false-positive biopsy recommendation rate per 1000 examinations (65.0 vs 162.6; difference, -97.6; 95% CI: -146.3, -50.8), and higher specificity (87.8% vs 80.2%; difference, 7.6%; 95% CI: 2.3, 13.1). Compared with standard MRI, CEM had significantly lower cancer detection rate (22.4 vs 36.6; difference, -14.2; 95% CI: -28.5, -2.0) and sensitivity (61.1% vs 100%; difference, -38.9%; 95% CI: -66.7, -12.5). The performance differences between CEM and ABMRI were similar to those observed between CEM and standard MRI. Conclusion ABMRI had comparable performance to standard MRI and may support more efficient MRI screening. CEM had lower recall and higher specificity compared with standard MRI or ABMRI, offset by lower cancer detection rate and sensitivity compared with standard MRI. These trade-offs warrant further consideration of patient population characteristics before widespread screening with CEM. Clinical trial registration no. NCT03517813 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Chang in this issue.


Assuntos
Neoplasias da Mama , Feminino , Humanos , Pessoa de Meia-Idade , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Estudos Prospectivos , Sensibilidade e Especificidade , Detecção Precoce de Câncer/métodos , Mamografia/métodos , Imageamento por Ressonância Magnética/métodos
8.
J Breast Imaging ; 5(3): 351-359, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37223454

RESUMO

Many factors are involved in the successful development of early career breast imaging radiologists into independent investigators conducting impactful research. Key basic prerequisites for success include a motivated and resilient radiologist, institutional and departmental commitment to supporting early career physician-scientists, strong mentorship, and a flexible strategy for extramural funding that accounts for individualized professional goals. In this review, we describe these factors in greater detail, providing a practical overview for residents, fellows, and junior faculty who are interested in an academic career as a breast imaging radiologist engaged in original scientific research. We also describe the essential pieces of grant applications and summarize the professional milestones for early career physician-scientists as they look toward promotion to associate professor and sustained extramural funding.

11.
J Therm Biol ; 111: 103437, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36585071

RESUMO

OBJECTIVES: To determine the impact of physical activity on temperature after within-limb calibration (TAWiC) measures and their reproducibility. To determine if thermal imaging from a smartphone attached thermal camera is comparable to thermal imaging using a handheld thermal camera for detection of arthritis in children. METHODS: Children without symptoms were enrolled to the "asymptomatic exercise cohort", and received infrared imaging, using a standard handheld camera, after initial resting period, after activity, and after second resting period. Children seen in the rheumatology clinic with knee pain were enrolled into the "symptomatic knee pain cohort" and received imaging with both the smartphone-attached and handheld cameras before a routine clinical exam. TAWiC was defined as the temperature differences between joint and ipsilateral mid-tibia as the main readout for arthritis detection. RESULTS: The asymptomatic exercise cohort demonstrated notable changes in absolute and TAWiC temperatures collected by thermal imaging after physical activity, and temperatures did not consistently return to pre-activity levels after a second period of rest. The 95th TAWiC from anterior view were, resting one -0.1 C (0.5), activity -0.7 C (0.5), resting two -0.2 C (0.6) (resting 1 vs resting 2, p-value = 0.13). In the symptomatic knee pain cohort, the smartphone attached and handheld thermal cameras performed similarly in regards to detection of joint inflammation and evaluation of joint temperature using the TAWiC algorithm, with high sensitivity of 80% (55.2-100.0%) and specificity of 84.2% (76.0-92.4%) in the anterior knee view when compared with the gold standard joint exam performed by a pediatric rheumatologist. The mean 95th TAWiC temperature difference between the two cameras was -0.1 C (-0.1 to 0.0) (p = 0.0004). CONCLUSIONS: This study showed continued validity of the TAWiC algorithm across two distinct thermal camera platforms and demonstrates promise for improved accessibility and utility of this technology for arthritis detection.


Assuntos
Artrite , Smartphone , Humanos , Criança , Reprodutibilidade dos Testes , Temperatura Corporal , Dor
12.
Cancers (Basel) ; 14(18)2022 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-36139594

RESUMO

This study tested the hypothesis that a change in the apparent diffusion coefficient (ADC) measured in diffusion-weighted MRI (DWI) is an independent imaging marker, and ADC performs better than functional tumor volume (FTV) for assessing treatment response in patients with locally advanced breast cancer receiving neoadjuvant immunotherapy. A total of 249 patients were randomized to standard neoadjuvant chemotherapy with pembrolizumab (pembro) or without pembrolizumab (control). DCE-MRI and DWI, performed prior to and 3 weeks after the start of treatment, were analyzed. Percent changes of tumor ADC metrics (mean, 5th to 95th percentiles of ADC histogram) and FTV were evaluated for the prediction of pathologic complete response (pCR) using a logistic regression model. The area under the ROC curve (AUC) estimated for the percent change in mean ADC was higher in the pembro cohort (0.73, 95% confidence interval [CI]: 0.52 to 0.93) than in the control cohort (0.63, 95% CI: 0.43 to 0.83). In the control cohort, the percent change of the 95th percentile ADC achieved the highest AUC, 0.69 (95% CI: 0.52 to 0.85). In the pembro cohort, the percent change of the 25th percentile ADC achieved the highest AUC, 0.75 (95% CI: 0.55 to 0.95). AUCs estimated for percent change of FTV were 0.61 (95% CI: 0.39 to 0.83) and 0.66 (95% CI: 0.47 to 0.85) for the pembro and control cohorts, respectively. Tumor ADC may perform better than FTV to predict pCR at an early treatment time-point during neoadjuvant immunotherapy.

13.
Tomography ; 8(3): 1208-1220, 2022 04 22.
Artigo em Inglês | MEDLINE | ID: mdl-35645385

RESUMO

This study evaluated the inter-reader agreement of tumor apparent diffusion coefficient (ADC) measurements performed on breast diffusion-weighted imaging (DWI) for assessing treatment response in a multi-center clinical trial of neoadjuvant chemotherapy (NAC) for breast cancer. DWIs from 103 breast cancer patients (mean age: 46 ± 11 years) acquired at baseline and after 3 weeks of treatment were evaluated independently by two readers. Three types of tumor regions of interests (ROIs) were delineated: multiple-slice restricted, single-slice restricted and single-slice tumor ROIs. Compared to tumor ROIs, restricted ROIs were limited to low ADC areas of enhancing tumor only. We found excellent agreement (intraclass correlation coefficient [ICC] ranged from 0.94 to 0.98) for mean ADC. Higher ICCs were observed in multiple-slice restricted ROIs (range: 0.97 to 0.98) than in other two ROI types (both in the range of 0.94 to 0.98). Among the three ROI types, the highest area under the receiver operating characteristic curves (AUCs) were observed for mean ADC of multiple-slice restricted ROIs (0.65, 95% confidence interval [CI]: 0.52-0.79 and 0.67, 95% CI: 0.53-0.81 for Reader 1 and Reader 2, respectively). In conclusion, mean ADC values of multiple-slice restricted ROI showed excellent agreement and similar predictive performance for pathologic complete response between the two readers.


Assuntos
Neoplasias da Mama , Adulto , Mama , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes
14.
Eur Radiol ; 32(10): 6588-6597, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35507050

RESUMO

OBJECTIVES: To perform a survey among all European Society of Breast Imaging (EUSOBI) radiologist members to gather representative data regarding the clinical use of breast DWI. METHODS: An online questionnaire was developed by two board-certified radiologists, reviewed by the EUSOBI board and committees, and finally distributed among EUSOBI active and associated (not based in Europe) radiologist members. The questionnaire included 20 questions pertaining to technical preferences (acquisition time, magnet strength, breast coils, number of b values), clinical indications, imaging evaluation, and reporting. Data were analyzed using descriptive statistics, the Chi-square test of independence, and Fisher's exact test. RESULTS: Of 1411 EUSOBI radiologist members, 275/1411 (19.5%) responded. Most (222/275, 81%) reported using DWI as part of their routine protocol. Common indications for DWI include lesion characterization (using an ADC threshold of 1.2-1.3 × 10-3 mm2/s) and prediction of response to chemotherapy. Members most commonly acquire two separate b values (114/217, 53%), with b value = 800 s/mm2 being the preferred value for appraisal among those acquiring more than two b values (71/171, 42%). Most did not use synthetic b values (169/217, 78%). While most mention hindered diffusion in the MRI report (161/213, 76%), only 142/217 (57%) report ADC values. CONCLUSION: The utilization of DWI in clinical practice among EUSOBI radiologists who responded to the survey is generally in line with international recommendations, with the main application being the differentiation of benign and malignant enhancing lesions, treatment response assessment, and prediction of response to chemotherapy. Report integration of qualitative and quantitative DWI data is not uniform. KEY POINTS: • Clinical performance of breast DWI is in good agreement with the current recommendations of the EUSOBI International Breast DWI working group. • Breast DWI applications in clinical practice include the differentiation of benign and malignant enhancing, treatment response assessment, and prediction of response to chemotherapy. • Report integration of DWI results is not uniform.


Assuntos
Neoplasias da Mama , Imagem de Difusão por Ressonância Magnética , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Sensibilidade e Especificidade , Inquéritos e Questionários
15.
Tomography ; 8(2): 701-717, 2022 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-35314635

RESUMO

In diffusion-weighted MRI (DW-MRI), choice of b-value influences apparent diffusion coefficient (ADC) values by probing different aspects of the tissue microenvironment. As a secondary analysis of the multicenter ECOG-ACRIN A6698 trial, the purpose of this study was to investigate the impact of alternate b-value combinations on the performance and repeatability of tumor ADC as a predictive marker of breast cancer treatment response. The final analysis included 210 women who underwent standardized 4-b-value DW-MRI (b = 0/100/600/800 s/mm2) at multiple timepoints during neoadjuvant chemotherapy treatment and a subset (n = 71) who underwent test−retest scans. Centralized tumor ADC and perfusion fraction (fp) measures were performed using variable b-value combinations. Prediction of pathologic complete response (pCR) based on the mid-treatment/12-week percent change in each metric was estimated by area under the receiver operating characteristic curve (AUC). Repeatability was estimated by within-subject coefficient of variation (wCV). Results show that two-b-value ADC calculations provided non-inferior predictive value to four-b-value ADC calculations overall (AUCs = 0.60−0.61 versus AUC = 0.60) and for HR+/HER2− cancers where ADC was most predictive (AUCs = 0.75−0.78 versus AUC = 0.76), p < 0.05. Using two b-values (0/600 or 0/800 s/mm2) did not reduce ADC repeatability over the four-b-value calculation (wCVs = 4.9−5.2% versus 5.4%). The alternate metrics ADCfast (b ≤ 100 s/mm2), ADCslow (b ≥ 100 s/mm2), and fp did not improve predictive performance (AUCs = 0.54−0.60, p = 0.08−0.81), and ADCfast and fp demonstrated the lowest repeatability (wCVs = 6.71% and 12.4%, respectively). In conclusion, breast tumor ADC calculated using a simple two-b-value approach can provide comparable predictive value and repeatability to full four-b-value measurements as a marker of treatment response.


Assuntos
Neoplasias da Mama , Imagem de Difusão por Ressonância Magnética , Benchmarking , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Terapia Neoadjuvante/métodos , Curva ROC , Microambiente Tumoral
16.
Radiol Imaging Cancer ; 4(1): e210063, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-35029517

RESUMO

Purpose To examine the clinical value of multiband (MB) sensitivity encoding (SENSE)-accelerated diffusion-weighted imaging (DWI) for breast imaging by performing quantitative and qualitative comparisons with conventional diffusion-weighted echo-planar imaging, or conventional DWI (cDWI). Materials and Methods In this prospective study (ClinicalTrials.gov identifier NCT03607552), women with breast cancer were recruited from July 2018 to July 2019 to undergo additional MB SENSE DWI during clinical 3-T breast MRI examinations. The cDWI and MB SENSE DWI acquisitions were assessed both quantitatively and qualitatively. Regions of interest were defined for tumorous and normal tissue, and the tumor apparent diffusion coefficient (ADC), contrast-to-noise ratio (CNR), and signal index (SI) were calculated for both DWI methods. Three readers independently reviewed the two acquisitions side by side and provided relative image quality scores. Tumor ADC, CNR, and SI measures were compared between cDWI and MB SENSE DWI acquisitions by using a paired t test, and reader preferences were evaluated by using the sign test. Results The study included 38 women (median age, 48 years; range, 28-83 years). Overall agreement was good between cDWI and MB SENSE DWI tumor ADC measures (intraclass correlation coefficient, 0.87 [95% CI: 0.75, 0.94]), and no differences were evident in the ADC (median, 0.93 × 10-3 mm2/sec vs 0.87 ×10-3 mm2/sec; P = .50), CNR (2.2 vs 2.3; P = .17), or SI (9.2 vs 9.2; P = .23) measurements. The image quality of cDWI and MB SENSE DWI acquisitions were considered equal for 51% of images (58 of 114), whereas MB SENSE DWI was preferred more often than cDWI (37% [42 of 114] vs 12% [14 of 114]; P < .001). The preference for MB SENSE DWI was most often attributed to better fat suppression. Conclusion MB SENSE can be used to accelerate breast DWI acquisition times without compromising the image quality or the fidelity of quantitative ADC measurements. Keywords: MR-Diffusion-weighted Imaging, Breast, Comparative Studies, Technology Assessment Clinical trial registration no. NCT03607552 © RSNA, 2022.


Assuntos
Neoplasias da Mama , Imagem de Difusão por Ressonância Magnética , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos
17.
J Rheumatol ; 49(1): 81-88, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34210832

RESUMO

OBJECTIVE: To standardize and improve the accuracy of detection of arthritis by thermal imaging. METHODS: Children with clinically active arthritis in the knee or ankle, as well as healthy controls, were enrolled to the development cohort; another group of children with knee symptoms was enrolled to the validation cohort. Ultrasound was performed in the arthritis subgroup for the development cohort. Joint exam by certified rheumatologists was used as a reference for the validation cohort. Infrared thermal data were analyzed using custom software. Temperature after within-limb calibration (TAWiC) was defined as the temperature differences between joint and ipsilateral mid-tibia. TAWiC of knees and ankles was evaluated using ANOVA across subgroups. Optimal thresholds were determined by receiver-operating characteristic analysis using Youden index. RESULTS: There were significant differences in mean and 95th TAWiC of knee in anterior, medial, lateral views, and of ankles in anterior view, between inflamed and uninflamed counterparts (P < 0.05). The area under the curve was higher by 30% when using TAWiCknee than that when using absolute temperature. Within the validation cohort, the sensitivity of accurate detection of arthritis in the knees using both mean and 95th TAWiC from individual views or all 3 views combined ranged from 0.60 to 0.70, and the specificity was > 0.90 in all views. CONCLUSION: Children with active arthritis or tenosynovitis in knees or ankles exhibited higher TAWiC than healthy joints. Our validation cohort study showed promise for the clinical utility of infrared thermal imaging for arthritis detection.


Assuntos
Artrite Juvenil , Perna (Membro) , Algoritmos , Artrite Juvenil/diagnóstico por imagem , Calibragem , Criança , Estudos de Coortes , Humanos , Articulação do Joelho/diagnóstico por imagem
18.
Radiology ; 301(2): 295-308, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34427465

RESUMO

Background Suppression of background parenchymal enhancement (BPE) is commonly observed after neoadjuvant chemotherapy (NAC) at contrast-enhanced breast MRI. It was hypothesized that nonsuppressed BPE may be associated with inferior response to NAC. Purpose To investigate the relationship between lack of BPE suppression and pathologic response. Materials and Methods A retrospective review was performed for women with menopausal status data who were treated for breast cancer by one of 10 drug arms (standard NAC with or without experimental agents) between May 2010 and November 2016 in the Investigation of Serial Studies to Predict Your Therapeutic Response with Imaging and Molecular Analysis 2, or I-SPY 2 TRIAL (NCT01042379). Patients underwent MRI at four points: before treatment (T0), early treatment (T1), interregimen (T2), and before surgery (T3). BPE was quantitatively measured by using automated fibroglandular tissue segmentation. To test the hypothesis effectively, a subset of examinations with BPE with high-quality segmentation was selected. BPE change from T0 was defined as suppressed or nonsuppressed for each point. The Fisher exact test and the Z tests of proportions with Yates continuity correction were used to examine the relationship between BPE suppression and pathologic complete response (pCR) in hormone receptor (HR)-positive and HR-negative cohorts. Results A total of 3528 MRI scans from 882 patients (mean age, 48 years ± 10 [standard deviation]) were reviewed and the subset of patients with high-quality BPE segmentation was determined (T1, 433 patients; T2, 396 patients; T3, 380 patients). In the HR-positive cohort, an association between lack of BPE suppression and lower pCR rate was detected at T2 (nonsuppressed vs suppressed, 11.8% [six of 51] vs 28.9% [50 of 173]; difference, 17.1% [95% CI: 4.7, 29.5]; P = .02) and T3 (nonsuppressed vs suppressed, 5.3% [two of 38] vs 27.4% [48 of 175]; difference, 22.2% [95% CI: 10.9, 33.5]; P = .003). In the HR-negative cohort, patients with nonsuppressed BPE had lower estimated pCR rate at all points, but the P values for the association were all greater than .05. Conclusions In hormone receptor-positive breast cancer, lack of background parenchymal enhancement suppression may indicate inferior treatment response. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Philpotts in this issue.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Quimioterapia Adjuvante/métodos , Meios de Contraste , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Terapia Neoadjuvante/métodos , Adulto , Idoso , Mama/diagnóstico por imagem , Estudos de Coortes , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
19.
J Breast Imaging ; 3(3): 288-298, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34061121

RESUMO

OBJECTIVE: To determine whether invasive lobular carcinoma (ILC) extent is more accurately depicted with preoperative MRI (pMRI) than conventional imaging (mammography and/or ultrasound). METHODS: After IRB approval, we retrospectively identified women with pMRIs (February 2005 to January 2014) to evaluate pure ILC excluding those with ipsilateral pMRI BI-RADS 4 or 5 findings or who had neoadjuvant chemotherapy. Agreement between imaging and pathology sizes was summarized using Bland-Altman plots, absolute and percent differences, and the intraclass correlation coefficient (ICC). Rates of underestimation and overestimation were evaluated and their associations with clinical features were explored. RESULTS: Among the 56 women included, pMRI demonstrated better agreement with pathology than conventional imaging by mean absolute difference (1.6 mm versus -7.8 mm, P < 0.001), percent difference (10.3% versus -16.4%, P < 0.001), and ICC (0.88 versus 0.61, P = 0.019). Conventional imaging more frequently underestimated ILC span than pMRI using a 5 mm difference threshold (24/56 (43%) versus 10/56 (18%), P < 0.001), a 25% threshold (19/53 (36%) versus 10/53 (19%), P = 0.035), and T category change (17/56 (30%) versus 7/56 (13%), P = 0.006). Imaging-pathology size concordance was greater for MRI-described solitary masses than other lesions for both MRI and conventional imaging (P < 0.05). Variability of conventional imaging was lower for patients ≥ the median age of 62 years than for younger patients (SD: 12 mm versus 22 mm, P = 0.012). CONCLUSION: MRI depicts pure ILC more accurately than conventional imaging and may have particular value for younger women.

20.
NPJ Breast Cancer ; 7(1): 42, 2021 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-33863924

RESUMO

Angiogenesis is a critical component of breast cancer development, and identification of imaging-based angiogenesis assays has prognostic and treatment implications. We evaluated the association of semi-quantitative kinetic and radiomic breast cancer features on dynamic contrast-enhanced (DCE)-MRI with microvessel density (MVD), a marker for angiogenesis. Invasive breast cancer kinetic features (initial peak percent enhancement [PE], signal enhancement ratio [SER], functional tumor volume [FTV], and washout fraction [WF]), radiomics features (108 total features reflecting tumor morphology, signal intensity, and texture), and MVD (by histologic CD31 immunostaining) were measured in 27 patients (1/2016-7/2017). Lesions with high MVD levels demonstrated higher peak SER than lesions with low MVD (mean: 1.94 vs. 1.61, area under the receiver operating characteristic curve [AUC] = 0.79, p = 0.009) and higher WF (mean: 50.6% vs. 22.5%, AUC = 0.87, p = 0.001). Several radiomics texture features were also promising for predicting increased MVD (maximum AUC = 0.84, p = 0.002). Our study suggests DCE-MRI can non-invasively assess breast cancer angiogenesis, which could stratify biology and optimize treatments.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA