Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 99
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38888435

RESUMO

We investigated whether Ramadan, a yearly religious fasting lasting for one month, could challenge the metabolic control obtained under a hybrid closed-loop (HCL) therapy in patients living with type 1 diabetes (T1D). This real-life prospective study involved 20 patients with T1D and moderate to high-risk score of adverse events at baseline. We compared continuous glucose monitoring (CGM) parameters under HCL therapy one month before and during the Ramadan fasting month. The main outcome was the evolution of the percentage of time-in-range (TIR, 70-180 mg/dL) between the two time points, and secondary outcomes were the evolution of other CGM parameters and frequency of acute metabolic events. We observed no statistical difference regarding TIR (mean±SD) (63±11 % during fasting versus 62±12 % before) as well as for other parameters including time spent under 70 mg/dL (1.1±1.0% versus 1.5±1.3%) and percentage of HCL use (93±5% versus 94±5%). No acute metabolic event was observed during fasting under HCL. Results were homogenous across baseline risk score groups.

2.
Diabetes Metab ; 50(4): 101544, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38788339

RESUMO

Pancreatic diabetes is associated with glycemic variability, poor metabolic control, and reduced quality of life. Though hybrid closed-loop (HCL) insulin delivery systems were not originally developed for these types of diabetes, they could address the therapeutic challenge. We aimed to evaluate long-term metabolic control in ten adult patients (mean ± SD age: 59 ± 12) treated with HCL insulin delivery systems for pancreatitis or pancreatectomy-induced diabetes. After a median of 346 days (range 64 - 631) with HCL insulin delivery, continuous glucose monitoring showed 59±19 % time-in-range [70-180 mg/dl] (versus 49±24 % before HCL insulin delivery, P = 0. 049) and 0.8 ± 1.0 % time-below-range [< 70 mg/dl] (versus 2.2 ± 2.6 %, P = 0.142), with the coefficient of glucose variability at 35.4 ± 7.6 (versus 37.8 ± 7.1, P = 0.047). HbA1c decreased from 8.5 ± 1.7 % to 7.7 ± 1.3 % [69±18 to 60±14 mmol/mol] (P = 0.076). No patient experienced an acute adverse metabolic event.

3.
Diabetes Ther ; 15(6): 1349-1360, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38642261

RESUMO

INTRODUCTION: Second-generation basal insulins like glargine 300 U/mL (Gla-300) have a longer duration of action and less daily fluctuation and interday variability than first-generation ones, such as glargine 100 U/mL (Gla-100). The EF-BI study, a nationwide observational, retrospective study, was designed to compare persistence, acute care complications, and healthcare costs associated with the initiation of such basal insulins (BI) in a real-life setting in France. METHODS: This study was conducted using the French healthcare claims database (SNDS). Adult patients living with type 1 or type 2 diabetes mellitus (T1DM or T2DM) initiating Gla-300 or Gla-100 ± other hypoglycemic medications between January 1, 2016 and December 31, 2020, and without any insulin therapy over the previous 6 months were included. Persistence was defined as remaining on the same insulin therapy until discontinuation defined by a 6 month period without insulin reimbursement. Hospitalized acute complications were identified using ICD-10 codes. Total collective costs were established for patients treated continuously with each basal insulin over 1-3 years. All comparisons were adjusted using a propensity score based on initial patient/treatment characteristics. RESULTS: A total of 235,894 patients with T2DM and 6672 patients with T1DM were included. Patients treated with Gla-300 were 83% (T1DM) and 44% (T2DM) less likely to discontinue their treatment than those treated with Gla-100 after 24 months (p < 0.0001). The annual incidence of acute hospitalized events in patients with T2DM treated with Gla-300 was 12% lower than with Gla-100 (p < 0.0001) but similar in patients with T1DM. Comparison of overall costs showed moderate but statistically significant differences in favor of Gla-300 versus Gla-100 for all patients over the first year, and in T2DM only over a 3-year follow-up. CONCLUSION: Use of Gla-300 resulted in a better persistence, less acute hospitalized events at least in T2DM, and reduced healthcare expenditure. These real-life results confirmed the potential interest of using Gla-300 rather than Gla-100.

4.
Diabetes Technol Ther ; 26(6): 426-432, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38236643

RESUMO

Aim: To evaluate the evolution of glycemic outcomes in patients living with type 1 diabetes (T1D) after 1 year of use of the MiniMed 780G advanced hybrid closed-loop (AHCL) system. Methods: We conducted an observational, retrospective, multicentric study in 20 centers in France. The primary objective was to evaluate the improvement in glycemic control after 1-year use of AHCL. The primary endpoint was the variation of time in range (TIR) between pre-AHCL and after 1-year use of AHCL. Secondary objectives were to analyze the glycemic outcomes after 3, 6, and 12 months of AHCL use, the safety, and the long-term observance of AHCL. Results: Two hundred twenty patients were included, and 200 were analyzed for the primary endpoint. 92.7% of patients continued to use AHCL. After 1 year of use of AHCL, TIR was 72.5% ± 10.6% (+9.1%; 95% confidence interval [CI] [7.6-10.5] compared to pre-AHCL initiation, P < 0.001), HbA1c 7.1% ± 0.7% (-0.5%; 95% CI [-0.6 to -0.4]; P < 0.001), time below range 2.0% [1.0; 3.0] (0.0% [-2.0; 0.0], P < 0.001), and time above range 24.8% ± 10.9% (-7.3%; 95% CI [-8.8 to -5.7]; P < 0.001). More patients achieved the glycemic treatment goals of HbA1c <7.0% (45.1% vs. 18.1%, P < 0.001) and TIR >70% (59.0% vs. 29.5% P < 0.001) when compared with pre-AHCL. Five patients experienced severe hypoglycemia events and two patients experienced ketoacidosis. Conclusion: After 1 year of use of AHCL, people living with T1D safely improved their glucose control and a higher proportion of them achieved optimal glycemic control.


Assuntos
Automonitorização da Glicemia , Glicemia , Diabetes Mellitus Tipo 1 , Controle Glicêmico , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/sangue , Estudos Retrospectivos , Masculino , Feminino , França , Adulto , Glicemia/análise , Hipoglicemiantes/uso terapêutico , Hipoglicemiantes/administração & dosagem , Controle Glicêmico/métodos , Insulina/administração & dosagem , Insulina/uso terapêutico , Pessoa de Meia-Idade , Hemoglobinas Glicadas/análise , Resultado do Tratamento , Hipoglicemia/prevenção & controle , Hipoglicemia/induzido quimicamente
5.
Diabetes Technol Ther ; 26(2): 125-129, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37955849

RESUMO

To evaluate the percentage of patients with type 1 diabetes (T1D) and very poor metabolic control who would agree to be treated with a hybrid closed-loop (HCL) insulin delivery system, and to assess metabolic improvement and safety. In a single center, we identified all patients aged >18 years with hemoglobin A1c (HbA1c) >11% (97 mmol/mol) before HCL treatment. We collected metabolic control and safety data up to 1 year post-HCL in those who accepted HCL after it was proposed to them. We identified 65 patients eligible for the study, 32 (50%) already used, or accepted to start using HCL. Patients were aged 18-49 years; mean(±standard deviation) baseline HbA1c was 12.5(±1.8)% (113 ± 20 mmol/mol). After 1 year, 25 patients (78%) were still using HCL and their mean HbA1c decreased to 9.4(±1.9)% (79 mmol/mol) (P < 0.001). The rate of acute metabolic events was similar during the year of follow-up to the rate in the 3 years before HCL initiation. HCL systems should be considered in patients with T1D and very poor metabolic control. ClinicalTrials registration no. NCT05282264.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina/uso terapêutico , Hipoglicemiantes/uso terapêutico , Glicemia , Hemoglobinas Glicadas , Sistemas de Infusão de Insulina , Insulina Regular Humana/uso terapêutico , Automonitorização da Glicemia
6.
World J Diabetes ; 14(11): 1710-1716, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-38077801

RESUMO

BACKGROUND: The correction and control of chronic hyperglycemia are the management goals of patients living with diabetes. Chronic hyperglycemia is the main factor inducing diabetes-related complications. However, in certain situations, the rapid and intense correction of chronic hyperglycemia can paradoxically favor the onset of microvascular complications. CASE SUMMARY: In this case report, we describe the case of a 25-year-old woman living with type 1 diabetes since the age of 9 years. Her diabetes was chronic and unstable but without complications. During an unplanned pregnancy, her diabetes was intensely managed with the rapid correction of her hyperglycemia. However, over the following 2 years, she developed numerous degenerative microvascular complications: Charcot neuroarthropathy with multiple joint involvement, severe proliferative diabetic retinopathy, gastroparesis, bladder voiding disorders, and end-stage renal failure requiring hemodialysis. CONCLUSION: In the literature to date, the occurrence of multiple microvascular complications following the rapid correction of chronic hyperglycemia has been rarely described in the same individual.

7.
J Diabetes Sci Technol ; : 19322968231208690, 2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37937589

RESUMO

BACKGROUND: Type 1 diabetes (T1D) is a complex condition requiring constant monitoring and self-management. The landscape of diabetes management is evolving with the development of new technologies. This survey aimed to gain insight into the perceptions and experiences of people with T1D (PWD) and their caregivers on the use of technology in diabetes care, and identify future needs for T1D management. METHODS: PWD and caregivers (≥18 years) living in five European countries (France, Germany, Italy, Spain, and the United Kingdom) completed an online survey. Data were collected during July and August 2021. RESULTS: Responders included 458 PWD and 54 caregivers. More than 60% of PWD perceived devices/digital tools for diabetes management as useful and 63% reported that access to monitoring device data made their life easier. Nearly half of participants hoped for new devices and/or digital tools. While approximately one-third of all PWD had used teleconsultation, perceptions and usage varied significantly between countries and by age (both P < .0001), with the lowest use in Germany (20%) and the highest in Spain (48%). The proportions of PWD contributing to diabetes care costs varied by device and were highest for smart insulin pen users at 83% compared with 44% for insulin pen users and 37% for insulin pump users. One-quarter (24%) of PWD and 15% of caregivers felt they lacked knowledge about devices/digital tools for T1D. CONCLUSIONS: Most PWD and caregivers had positive perceptions and experiences of new technologies/digital solutions for diabetes management, although improved support and structured education for devices/digital tools are still required.

8.
PLoS One ; 18(8): e0289684, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37616289

RESUMO

BACKGROUND: We assessed the performance and patient satisfaction of a new insulin patch pump, the A7+TouchCare (Medtrum), compared with the Omnipod system. METHODS: This multicenter, randomized, open-label, controlled study enrolled 100 adult patients with type 1 or type 2 diabetes mellitus (A1C ≥ 6.5% and ≤ 9.5%, i.e., 48 to 80 mmol/mol) who were assigned with the Omnipod or with the A7+TouchCare pump for 3 months. The primary study outcome was the glucose management indicator (GMI) calculated with continuous glucose monitoring (CGM). RESULTS: Premature withdrawals occurs respectively in 2 and 9 participants in the Omnipod and TouchCare groups. In the Per Protocol analysis, the difference in GMI between groups was 0.002% (95% confidence interval -0.251; 0.255). The non-inferiority was demonstrated since the difference between treatments did not overlap the pre-defined non-inferiority margin (0.4%). There was no significant difference in CGM parameters between groups. On average, patients in both groups were satisfied/very satisfied with the insulin pump system. Patients preferred Omnipod as an insulin management system and especially the patch delivery system but preferred the A7+TouchCare personal diabetes manager to control the system. CONCLUSIONS: This study showed that the A7+TouchCare insulin pump was as efficient as the Omnipod pump in terms of performance and satisfaction. CLINICAL TRAIL REGISTRATION: The study was registered in the ClinicalTrials.gov protocol register (NCT04223973).


Assuntos
Diabetes Mellitus Tipo 2 , Insulinas , Adulto , Humanos , Satisfação do Paciente , Automonitorização da Glicemia , Diabetes Mellitus Tipo 2/tratamento farmacológico , Glicemia
9.
Pharmaceutics ; 15(7)2023 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-37513978

RESUMO

Diabetes complications can be related to the long duration of the disease or chronic hyperglycemia. The follow-up of diabetic patients is based on the control of chronic hyperglycemia, although this correction, if obtained rapidly in people living with severe chronic hyperglycemia, can paradoxically interfere with the disease or even induce complications. We reviewed the literature describing the impact of the rapid and intense treatment of hyperglycemia on diabetic complications. The literature review showed that worsening complications occurred significantly in diabetic microangiopathy with the onset of specific neuropathy induced by the correction of diabetes. The results for macroangiopathy were somewhat mixed with the intensive and rapid correction of chronic hyperglycemia having a neutral impact on stroke and myocardial infarction but a significant increase in cardiovascular mortality. The management of diabetes has now entered a new era with new therapeutic molecules, such as gliflozin for patients living with type 2 diabetes, or hybrid insulin delivery systems for patients with insulin-treated diabetes. Our manuscript provides evidence in support of these personalized and progressive algorithms for the control of chronic hyperglycemia.

10.
J Diabetes Sci Technol ; 17(6): 1433-1439, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37449762

RESUMO

BACKGROUND: DBLG1 (Diabeloop Generation 1) stands as one of the five commercially available closed-loop solution worldwide for patients with type 1 diabetes as of 2023. Our aim was to provide an overview of all data obtained with this system regarding outcomes and populations, with an emphasis on interoperability. METHODS: This report includes all available sources of data (three randomized control trials and five surveys on real-life data). Collection ran from March 3, 2017 to April 30, 2022. RESULTS: We gathered data from 6859 adult patients treated with closed-loop from three to 12 months. Overall, all sources of data showed that time in range (TIR) 70 to 180 mg/dL, starting from 47.4% to 56.6%, improved from 12.2 to 17.3 percentage points. Time in hypoglycemia was reduced by 48% in average (range: 26%-70%) and reached a level of 1.3% in the largest and most recent cohort. In patients with excessive time in hypoglycemia at baseline (≥5%), closed-loop allowed a reduction in time below range (TBR) by 59%. The comparison of days with declared physical activity versus days without physical activity did not show differences in TBR. The improvement in TIR observed with three different pump systems (Vicentra Kaleido, n = 117; Sooil Dana-I, n = 84; and Roche Insight, n = 6684) ranged from 15.4 to 17.3 percentage points. DISCUSSION: These data obtained in different European countries were consistent throughout all reports, showing that this closed-loop system is efficient (high improvement in TIR), safe (remarkably low level of TBR), and interoperable (three pump settings so far).


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Adulto , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina/uso terapêutico , Hipoglicemiantes/uso terapêutico , Glicemia , Sistemas de Infusão de Insulina/efeitos adversos , Hipoglicemia/induzido quimicamente , Insulina Regular Humana/uso terapêutico
11.
Lancet Reg Health Eur ; 32: 100686, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37520145

RESUMO

Background: Two randomised controlled trials (RCTs) have previously shown that telemedical monitoring of diabetic foot ulcer (DFU) reduces the number of visits to the outpatient clinic, without losing treatment efficacy or increasing costs. Here we present the results of an open-label, randomised controlled trial designed to investigate whether telemonitoring, provided by an expert nurse (with extensive experience in DFU and trained in remote monitoring), reduces the hospital stay and the associated costs for a patient with DFU (TELEPIED trial). Methods: Eligible patients (n = 180) were randomly allocated to: (i) a control group, in which they received standard care, and (ii) an intervention group, in which they received asynchronous telemedicine follow-up by the expert nurse. The primary outcome was the cumulative hospital days over 12 months. The main secondary outcomes were (i) direct healthcare costs (estimated in a collective perspective), (ii) wound healing and (iii) amputation rates. ITT (intention-to-treat) population was analysed. Findings: In the ITT population, cumulative hospital days were significantly higher in the control group (13.4 days [95% CI 9.0-17.8]) than in the intervention group (7.1 days [2.8-11.5]) (p = 0.0458, ANCOVA model). Cumulative direct costs over 12 months were 7185 € (95% CI 5144-9226) in the control group and 3471 € (95% CI 1430-5512) in the intervention group (p = 0.0120). The percentage of wounds healed and amputation rate were not significantly different between groups. Similar results were found with the PP population. Interpretation: The implementation of a telemedical intervention with an expert nurse could lead to a length of hospitalization and direct costs that were two times lower compared to conventional follow-up. This lower medical and economic burden was obtained without losing effectiveness on the rate of healing, nor increasing the amputation rate. Additional studies are required to confirm these findings. Funding: This study was designed, funded and conducted by CERITD (Study and Research Centre for Intensification of Diabetes Treatment, Evry, France), Genopole GIP, 20 rue Henri Desbruères, 91030 EVRY Cedex and Laboratoires URGO, 15 Avenue d'Iéna, 75116 Paris Cedex, France. The findings and conclusions in this study are those of the authors and do not necessarily represent the views of the sponsor. The corresponding author (DD) certify that authors were not precluded from accessing data in the study, and they accept responsibility to submit for publication.

12.
J Am Geriatr Soc ; 71(7): 2107-2119, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36965179

RESUMO

BACKGROUND: There is a lack of real-life data regarding the frequency and predictive factors of hypoglycemia in older patients with type 2 diabetes (T2D). This study aimed to determine the frequency and predictors of hypoglycemia in older patients with insulin-treated T2D. METHODS: This prospective multicenter study included 155 insulin-treated T2D patients aged 75 years and older with ≥2 self-monitoring of blood glucose (SMBG) daily controls. Participants underwent a geriatric and diabetic assessment and received ambulatory blinded continuous glucose monitoring (CGM) for 28 consecutive days with FreeStyle Libre Pro® sensor. Study population (n = 141) has >70% CGM active time. Multivariable logistic regressions were used to identify factors associated with SMBG confirmed hypoglycemia (≥70 mg/dL) and with nocturnal level 2 time below range (glucose concentration <54 mg/dL during ≥15 consecutive min between 0.00 and 6.00 am). RESULTS: The mean age of the 141 analyzed patients was 81.5 ± 5.3 years and 56.7% were male. The mean baseline HbA1c was 7.9% ± 1.0%. After geriatric assessment, 102 participants (72.3%) were considered as complex and 39 (27.7%) as healthy. The primary endpoint (confirmed SMBG <70 mg/dL) occurred in 37.6% patients. In multivariable analysis, the risk of SMBG-confirmed hypoglycemia was positively associated with a longer duration of diabetes (OR (+1 year) =1.04, (1.00-1.08), p = 0.04) and glycemic variability assessed by CGM (CV %) (OR (+1%) = 1.12, [1.05-1.19], p = <0.001). Nighty-two patients (65.2%) experienced nocturnal time in hypoglycemia (i.e., <54 mg/dL during ≥15 consecutive min between midnight and 6 a.m.). In multivariable analyses, cognitive impairment (OR: 9.31 [2.59-33.4]), heart failure (OR: 4.81 [1;48-15.6]), and depressive disorder (OR: 0.19 [0.06-0.53]) were associated with nocturnal time in hypoglycemia. CONCLUSION: Nocturnal hypoglycemia is very common and largely underdiagnosed in older patients with insulin-treated T2D. CGM is a promising tool to better identify hypoglycemia and adapt diabetes management in this population.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Hipoglicemia , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Feminino , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/tratamento farmacológico , Insulina/efeitos adversos , Glicemia/análise , Automonitorização da Glicemia , Estudos Prospectivos , Hipoglicemia/induzido quimicamente , Hipoglicemia/epidemiologia , Hipoglicemiantes/efeitos adversos
13.
JMIR Diabetes ; 8: e44277, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36749650

RESUMO

BACKGROUND: For patients with type 2 diabetes (T2D), calculating the daily dose of basal insulin may be challenging. Insulia is a digital remote monitoring solution that uses clinical algorithms to recommend basal insulin doses. A predecessor device was evaluated in the TeleDiab-2 randomized controlled trial, showing that a higher percentage of patients using the app achieved their target fasting blood glucose (FBG) level compared to the control group, and insulin doses were adjusted to higher levels without hypoglycemia. OBJECTIVE: This study aims to analyze how the glycemic control of Insulia users has evolved when using the app in a real-life setting in France. METHODS: A retrospective observational analysis of data collected through the device in adult French patients with T2D treated with basal insulin and oral antihyperglycemic agents using the system for ≥6 months was conducted. Analyses were descriptive and distinguished the results in a subpopulation of regular and compliant users of the app. Glycemic outcomes were estimated considering the percentage of patients who achieved their individualized FBG target between 5.5 and 6 months following the initiation of device use, the frequency of hypoglycemia resulting in a treatment change over the 6-month period of exposure, and the evolution of the average hemoglobin A1c (HbA1c) level over the same period. RESULTS: Of the 484 users, 373 (77.1%) performed at least one dose calculation. A total of 221 (59.2%) users were men. When app use started, the mean age, BMI, HbA1c, and basal insulin dose were 55.8 (SD 11.9) years, 30.6 (SD 5.9) kg/m2, 10.1% (SD 2.0%), and 25.5 (SD 15.8) IU/day, respectively. Over a median use duration of 5.0 (95% CI 3.8-5.7) months, patients used the system 5.8 (SD 1.6) times per week on average, and 73.4% of their injected doses were consistent with the app's suggested doses. Among regular and compliant user patients (n=91, ≥5 measurements/week and ≥80% adherence to calculated doses), 60% (55/91) achieved the FBG target (±5%) at 6 months (5.5-6 months) versus 51.5% (145/282) of the other patients (P=.15). There was an increase in the proportion of patients achieving their target FBG for regular and compliant users (+1.86% every 2 weeks) without clear improvement in other patients. A logistic model did not identify the variables that were significantly associated with this outcome among regular and compliant users. In the overall population, the incidence of reported hypoglycemia decreased simultaneously (-0.16%/month). Among 82 patients, the mean HbA1c decreased from 9.9% to 7.2% at 6 months. CONCLUSIONS: An improvement in glycemic control as measured by the percentage of patients reaching their FBG individualized target range without increasing hypoglycemic risk was observed in patients using the Insulia app, especially among regular users following the dose recommendations of the algorithm.

14.
Healthcare (Basel) ; 10(12)2022 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-36553911

RESUMO

BACKGROUND: Iodine supplementation is indicated by the French National Authority for Health (HAS) and the World Health Organization (WHO) during pregnancy. This study investigates whether this supplementation is consistently prescribed in line with WHO recommendations in pregnant women diagnosed with gestational diabetes mellitus. METHOD: A total of 99 women with a diagnosis of gestational diabetes were included in the study and were all closely monitored. RESULTS: Only 17 (17.2%) patients received the recommended iodine supplementation. The follow-up, whether conducted by a gynecologist or midwife, did not influence the prescription of iodine supplements. By contrast, 72 (72.7%) of patients received folic acid supplementation. CONCLUSIONS: The prescription of iodine supplementation for the pregnant women included in our study is insufficient. Few practitioners seem aware of the recommendations, even when the pregnancy is complicated by gestational diabetes.

15.
Medicina (Kaunas) ; 58(12)2022 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-36556964

RESUMO

Charcot neuroarthropathy (CN) is a destructive complication of the joints in patients with diabetes and should be managed from the onset of the first symptoms to avoid joint deformity and the risk of amputating the affected joint. Here, we describe the case of a young 24-year-old patient living with type I diabetes who developed active bilateral CN in both tarsal joints. This case of neuroarthropathy was uncommon due to the bilateral presentation at the same level of the joint. Despite the patient consulting from the beginning of the symptoms, none of the physicians suspected or diagnosed CN, leading to a delay in management and the aggravation of bone destruction by CN. This highlights the importance of early management of CN with the need to refer people with suspected CN to specialised diabetic foot care centres.


Assuntos
Artropatia Neurogênica , Diabetes Mellitus Tipo 2 , Pé Diabético , Humanos , Adulto Jovem , Adulto , Diagnóstico Tardio/efeitos adversos , Artropatia Neurogênica/etiologia , Artropatia Neurogênica/complicações , Diabetes Mellitus Tipo 2/complicações
17.
PLoS One ; 17(5): e0268242, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35587931

RESUMO

The rate of recurrence for diabetic foot ulcer (DFU) is 50% at 2 years Armstrong DG, 2017. International recommendations call for regular monitoring to prevent DFU recurrence. We aim to investigate the relation between post-healing follow-up and recurrence rates. The study will begin in November 2021 and end in April 2022; final study results are scheduled for December 2022. The purpose of the study is to evaluate the benefit of the multidisciplinary follow-up of healed DFU patients at the rate of two annual consultations and its impact on foot wound recurrence.


Assuntos
Diabetes Mellitus , Pé Diabético , Pé Diabético/terapia , Seguimentos , Humanos , Estudos Interdisciplinares , Cicatrização
18.
Medicina (Kaunas) ; 58(4)2022 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-35454393

RESUMO

The RANKL-GLYC study aims to explore the impact of the rapid correction of chronic hyperglycemia on the receptor activator of nuclear factor-kappa B ligand (RANKL) and its antagonist osteoprotegerin (OPG). RANKL and OPG are considered the main factors in the pathophysiology of Charcot neuroarthropathy, a devastating complication of the joints that remains poorly understood. The study began recruiting patients in September 2021 and ends in June 2022; the final study results are scheduled for January 2023.


Assuntos
Diabetes Mellitus Tipo 2 , Hiperglicemia , Doença Crônica , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/tratamento farmacológico , Humanos , Hiperglicemia/tratamento farmacológico , NF-kappa B , Osteoprotegerina , Ligante RANK , Receptor Ativador de Fator Nuclear kappa-B
20.
Medicina (Kaunas) ; 58(2)2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-35208615

RESUMO

Background and Objectives: We describe a case of necrotic angiodermatitis. Materials and Methods: We used an intact fish skin graft to treat a patient living with diabetes, which was complicated by end-stage renal failure and arterial hypertension. The entire therapeutic procedure was carried out in ambulatory care without requiring the hospitalization of the patient. Results: The patient experienced a marked reduction in pain and complete epithelization of the lesion after 10 weeks of treatment. Conclusion: Our experience presents a new therapeutic approach to necrotic angiodermatitis.


Assuntos
Diabetes Mellitus , Úlcera da Perna , Diabetes Mellitus/patologia , Humanos , Úlcera da Perna/etiologia , Úlcera da Perna/patologia , Úlcera da Perna/cirurgia , Necrose/complicações , Necrose/patologia , Pele/patologia , Transplante de Pele/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA