Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39352423

RESUMO

PURPOSE: To assess the trends in administered 2-[18F]fluoro-2-deoxy-D-glucose ([18F]FDG) doses, computed tomography (CT) radiation doses, and image quality over the last 15 years in children with drug-resistant epilepsy (DRE) undergoing hybrid positron emission tomography (PET) brain scans. METHODS: We retrospectively analyzed data from children with DRE who had [18F]FDG-PET/CT or magnetic resonance scans for presurgical evaluation between 2005 and 2021. We evaluated changes in injected [18F]FDG doses, administered activity per body weight, CT dose index volume (CTDIvol), and dose length product (DLP). PET image quality was assessed visually by four trained raters. Conversely, CT image quality was measured using region-of-interest analysis, normalized by signal-to-noise (SNR) and contrast-to-noise ratio (CNR). RESULTS: We included 55 children (30 male, mean age: 9 ± 6 years) who underwent 61 [18F]FDG-PET scans (71% as PET/CT). Annually, the injected [18F]FDG dose decreased by ~ 1% (95% CI: 0.92%-0.98%, p < 0.001), with no significant changes in administered activity per body weight (p = 0.51). CTDIvol and DLP decreased annually by 16% (95% CI: 9%-23%) and 15% (95% CI: 8%-21%, both p < 0.001), respectively. PET image quality improved by 9% year-over-year (95% CI: 6%-13%, p < 0.001), while CT-associated SNR and CNR decreased annually by 7% (95% CI: 3%-11%, p = 0.001) and 6% (95% CI: 2%-10%, p = 0.008), respectively. CONCLUSION: Our findings indicate stability in [18F]FDG administered activity per body weight alongside improvements in PET image quality. Conversely, CT-associated radiation doses reduced. These results reaffirm [18F]FDG-PET as an increasingly safer and higher-resolution auxiliary imaging modality for children with DRE. These improvements, driven by technological advancements, may enhance the diagnostic precision and patient outcomes in pediatric epilepsy surgery.

2.
Nat Commun ; 15(1): 8402, 2024 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-39333526

RESUMO

The standard method for identifying active Brown Adipose Tissue (BAT) is [18F]-Fluorodeoxyglucose ([18F]-FDG) PET/CT imaging, which is costly and exposes patients to radiation, making it impractical for population studies. These issues can be addressed with computational methods that predict [18F]-FDG uptake by BAT from CT; earlier population studies pave the way for developing such methods by showing some correlation between the Hounsfield Unit (HU) of BAT in CT and the corresponding [18F]-FDG uptake in PET. In this study, we propose training convolutional neural networks (CNNs) to predict [18F]-FDG uptake by BAT from unenhanced CT scans in the restricted regions that are likely to contain BAT. Using the Attention U-Net architecture, we perform experiments on datasets from four different cohorts, the largest study to date. We segment BAT regions using predicted [18F]-FDG uptake values, achieving 23% to 40% better accuracy than conventional CT thresholding. Additionally, BAT volumes computed from the segmentations distinguish the subjects with and without active BAT with an AUC of 0.8, compared to 0.6 for CT thresholding. These findings suggest CNNs can facilitate large-scale imaging studies more efficiently and cost-effectively using only CT.


Assuntos
Tecido Adiposo Marrom , Fluordesoxiglucose F18 , Redes Neurais de Computação , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tecido Adiposo Marrom/diagnóstico por imagem , Tecido Adiposo Marrom/metabolismo , Humanos , Fluordesoxiglucose F18/farmacocinética , Fluordesoxiglucose F18/metabolismo , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Feminino , Masculino , Tomografia Computadorizada por Raios X/métodos , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos/farmacocinética , Compostos Radiofarmacêuticos/metabolismo , Idoso , Adulto
3.
Br J Radiol ; 2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-39189964

RESUMO

PURPOSE: This study assessed the potential of ultra-high-resolution (UHR) and a 1024-matrix in photon-counting-detector CT (PCD-CT) for evaluating interstitial lung disease (ILD) in systemic sclerosis (SSc) patients. MATERIALS AND METHODS: Sixty-six SSc patients who underwent ILD-CT screening on a first-generation PCD-CT were retrospectively included. Scans were performed in UHR mode at 100 kVp with two different matrix sizes (512x512 and 1024x1024) and reconstructed at slice thicknesses of 1.5 mm and 0.2 mm. Image noise, subjective image quality, and ILD changes (1) were evaluated on a 5-point Likert-scale by two independent readers. RESULTS: Interreader agreement for subjective image quality ranged from fair to almost perfect (Krippendorff-Alpha: 0.258-0.862). Overall image quality was highest for 1.5 mm/1024matrix images ((reader 1: 4 (4.4), reader 2: 5 (4.5)). Image sharpness was rated significantly better in 0.2 mm images (p < 0.001). Regarding ILD changes, 0.2 mm slice thickness outperformed 1.5 mm slice thickness significantly (p < 0.001), while there was no significant difference between the two matrix sizes. 1024 matrix size demonstrated superiority in evaluating coarse reticulations compared to 512matrix size. CONCLUSION: UHR mode with a 0.2 mm slice thickness showed enhanced image sharpness and improved visibility of ILD changes compared to standard reconstructions. This has the potential to enable the early detection of subtle disease manifestations. ADVANCES IN KNOWLEDGE: With the invention of PCD-CT different reconstruction algorithms need to be evaluated for specific pathologies. In our study ILD UHR mode with 0.2 mm slice thickness showed to be beneficial in the detection of parenchymal changes in patients with scleroderma.

5.
Invest Radiol ; 59(10): 684-690, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-38742928

RESUMO

OBJECTIVE: Photon-counting detector computed tomography (PCD-CT) enables spectral data acquisition of CT angiographies allowing for reconstruction of virtual monoenergetic images (VMIs) in routine practice. Specifically, it has potential to reduce the blooming artifacts associated with densely calcified plaques. However, calcium blooming and iodine attenuation are inversely affected by energy level (keV) of the VMIs, creating a challenge for contrast media (CM) injection protocol optimization. A pragmatic and simple rule for calcium-dependent CM injection protocols is investigated and proposed for VMI-based coronary CT angiography with PCD-CT. MATERIALS AND METHODS: A physiological circulation phantom with coronary vessels including calcified lesions (maximum CT value >700 HU) with a 50% diameter stenosis was injected into at iodine delivery rates (IDRs) of 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 2.5, and 3.0 g I/s. Images were acquired using a first-generation dual-source PCD-CT and reconstructed at various VMI levels (between 45 and 190 keV). Iodine attenuation in the coronaries was measured at each IDR for each keV, and blooming artifacts from the calcified lesions were assessed including stenosis grading error (as % overestimation vs true lumen). The IDR to achieve 300 HU at each VMI level was then calculated and compared with stenosis grading accuracy to establish a general rule for CM injection protocols. RESULTS: Plaque blooming artifacts and intraluminal iodine attenuation decreased with increasing keV. Fixed windowing (representing absolute worst case) resulted in stenosis overestimation from 77% ± 4% at 45 keV to 5% ± 2% at 190 keV, whereas optimized windowing resulted in overestimation from 29% ± 3% at 45 keV to 4% ± 1% at 190 keV. The required IDR to achieve 300 HU showed a strong linear correlation to VMI energy ( R2 = 0.98). Comparison of this linear plot versus stenosis grading error and blooming artifact demonstrated that multipliers of 1, 2, and 3 times the reference IDR for theoretical clinical regimes of no, moderate, and severe calcification density, respectively, can be proposed as a general rule. CONCLUSIONS: This study provides a proof-of-concept in an anthropomorphic phantom for a simple pragmatic adaptation of CM injection protocols in coronary CT angiography with PCD-CT. The 1-2-3 rule demonstrates the potential for reducing the effects of calcium blooming artifacts on overall image quality.


Assuntos
Artefatos , Angiografia por Tomografia Computadorizada , Meios de Contraste , Angiografia Coronária , Imagens de Fantasmas , Meios de Contraste/administração & dosagem , Humanos , Angiografia por Tomografia Computadorizada/métodos , Angiografia por Tomografia Computadorizada/instrumentação , Angiografia Coronária/métodos , Fótons , Cálcio , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
6.
Int J Cardiovasc Imaging ; 40(5): 951-966, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38700819

RESUMO

Almost 35 years after its introduction, coronary artery calcium score (CACS) not only survived technological advances but became one of the cornerstones of contemporary cardiovascular imaging. Its simplicity and quantitative nature established it as one of the most robust approaches for atherosclerotic cardiovascular disease risk stratification in primary prevention and a powerful tool to guide therapeutic choices. Groundbreaking advances in computational models and computer power translated into a surge of artificial intelligence (AI)-based approaches directly or indirectly linked to CACS analysis. This review aims to provide essential knowledge on the AI-based techniques currently applied to CACS, setting the stage for a holistic analysis of the use of these techniques in coronary artery calcium imaging. While the focus of the review will be detailing the evidence, strengths, and limitations of end-to-end CACS algorithms in electrocardiography-gated and non-gated scans, the current role of deep-learning image reconstructions, segmentation techniques, and combined applications such as simultaneous coronary artery calcium and pulmonary nodule segmentation, will also be discussed.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana , Vasos Coronários , Aprendizado Profundo , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Calcificação Vascular , Humanos , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Prognóstico , Angiografia por Tomografia Computadorizada , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Inteligência Artificial , Técnicas de Imagem de Sincronização Cardíaca
7.
EJNMMI Res ; 14(1): 36, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38578516

RESUMO

BACKGROUND: Liver uptake in [68Ga]Ga-PSMA-11 PET is used as an internal reference in addition to clinical parameters to select patients for [177Lu]Lu-PSMA-617 radioligand therapy (RLT). Due to increased demand, [68Ga]Ga-PSMA-11 was replaced by [18F]F-PSMA-1007, a more lipophilic tracer with different biodistribution and splenic uptake was suggested as a new internal reference. We compared the intra-patient tracer distribution between [68Ga]Ga-PSMA-11 and [18F]F-PSMA-1007. METHODS: Fifty patients who underwent PET examinations in two centers with both [18F]F-PSMA-1007 and [68Ga]Ga-PSMA-11 within one year were included. Mean standardized uptake values (SUVmean) were obtained for liver, spleen, salivary glands, blood pool, and bone. Primary tumor, local recurrence, lymph node, bone or visceral metastasis were also assessed for intra- and inter-individual comparison. RESULTS: Liver SUVmean was significantly higher with [18F]F-PSMA-1007 (11.7 ± 3.9) compared to [68Ga]Ga-PSMA-11 (5.4 ± 1.7, p < .05) as well as splenic SUVmean (11.2 ± 3.5 vs.8.1 ± 3.5, p < .05). The blood pool was comparable between the two scans. Malignant lesions did not show higher SUVmean on [18F]F-PSMA-1007. Intra-individual comparison of liver uptake between the two scans showed a linear association for liver uptake with SUVmean [68Ga]Ga-PSMA-11 = 0.33 x SUVmean [18F]F-PSMA-1007 + 1.52 (r = .78, p < .001). CONCLUSION: Comparing biodistribution of [68Ga]Ga and [18F]F tracers, liver uptake on [68Ga]Ga-PSMA-11 PET is the most robust internal reference value. Liver uptake of [18F]F-PSMA-1007 was significantly higher, but so was the splenic uptake. The strong intra-individual association of hepatic accumulation between the two scans may allow using of a conversion factor for [18F]F-PSMA-1007 as a basis for RLT selection.

8.
J Clin Med ; 13(8)2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38673617

RESUMO

Background: MRI diagnostics are important for adenomyosis, especially in cases with inconclusive ultrasound. This study assessed the potential of MRI-based radiomics as a novel tool for differentiating between uteri with and without adenomyosis. Methods: This retrospective proof-of-principle single-center study included nine patients with and six patients without adenomyosis. All patients had preoperative T2w MR images and histological findings served as the reference standard. The uterus of each patient was segmented in 3D using dedicated software, and 884 radiomics features were extracted. After dimension reduction and feature selection, the diagnostic yield of individual and combined features implemented in the machine learning models were assessed by means of receiver operating characteristics analyses. Results: Eleven relevant radiomics features were identified. The diagnostic performance of individual features in differentiating adenomyosis from the control group was high, with areas under the curve (AUCs) ranging from 0.78 to 0.98. The performance of ML models incorporating several features was excellent, with AUC scores of 1 and an area under the precision-recall curve of 0.4. Conclusions: The set of radiomics features derived from routine T2w MRI enabled accurate differentiation of uteri with adenomyosis. Radiomics could enhance diagnosis and furthermore serve as an imaging biomarker to aid in personalizing therapies and monitoring treatment responses.

9.
Invest Radiol ; 59(10): 677-683, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-38526041

RESUMO

OBJECTIVES: Calcified plaques induce blooming artifacts in coronary computed tomography angiography (CCTA) potentially leading to inaccurate stenosis evaluation. Tungsten represents a high atomic number, experimental contrast agent with different physical properties than iodine. We explored the potential of a tungsten-based contrast agent for photon-counting detector (PCD) CCTA in heavily calcified coronary vessels. MATERIALS AND METHODS: A cardiovascular phantom exhibiting coronaries with calcified plaques was imaged on a first-generation dual-source PCD-CT. The coronaries with 3 different calcified plaques were filled with iodine and tungsten contrast media solutions equating to iodine and tungsten delivery rates (IDR and TDR) of 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 2.5, and 3.0 g/s, respectively. Electrocardiogram-triggered sequential acquisitions were performed in the spectral mode (QuantumPlus). Virtual monoenergetic images (VMIs) were reconstructed from 40 to 190 keV in 1 keV increments. Blooming artifacts and percentage error stenoses from calcified plaques were quantified, and attenuation characteristics of both contrast media were recorded. RESULTS: Blooming artifacts from calcified plaques were most pronounced at 40 keV (78%) and least pronounced at 190 keV (58%). Similarly, percentage error stenoses were highest at 40 keV (48%) and lowest at 190 keV (2%), respectively. Attenuation of iodine decreased monotonically in VMIs from low to high keV, with the strongest decrease from 40 keV to 100 keV (IDR of 2.5 g/s: 1279 HU at 40 keV, 187 HU at 100 kV, and 35 HU at 190 keV). The attenuation of tungsten, on the other hand, increased monotonically as a function of VMI energy, with the strongest increase between 40 and 100 keV (TDR of 2.5 g/s: 202 HU at 40 keV, 661 HU at 100 kV, and 717 HU at 190 keV). For each keV level, the relationship between attenuation and IDR/TDR could be described by linear regressions ( R2 ≥ 0.88, P < 0.001). Specifically, attenuation increased linearly when increasing the delivery rate irrespective of keV level or contrast medium. Iodine exhibited the highest relative increase in attenuation values at lower keV levels when increasing the IDR. Conversely, for tungsten, the greatest relative increase in attenuation values occurred at higher keV levels when increasing the TDR. When high keV imaging is desirable to reduce blooming artifacts from calcified plaques, IDR has to be increased at higher keV levels to maintain diagnostic vessel attenuation (ie, 300 HU), whereas for tungsten, TDR can be kept constant or can be even reduced at high keV energy levels. CONCLUSIONS: Tungsten's attenuation characteristics in relation to VMI energy levels are reversed to those of iodine, with tungsten exhibiting high attenuation values at high keV levels and vice versa. Thus, tungsten shows promise for high keV imaging CCTA with PCD-CT as-in distinction to iodine-both high vessel attenuation and low blooming artifacts from calcified plaques can be achieved.


Assuntos
Artefatos , Angiografia por Tomografia Computadorizada , Meios de Contraste , Iodo , Imagens de Fantasmas , Tungstênio , Meios de Contraste/química , Angiografia por Tomografia Computadorizada/métodos , Humanos , Angiografia Coronária/métodos , Fótons , Vasos Coronários/diagnóstico por imagem
10.
Radiol Cardiothorac Imaging ; 6(2): e230217, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38451189

RESUMO

Purpose To compare image quality, diagnostic performance, and conspicuity between single-energy and multi-energy images for endoleak detection at CT angiography (CTA) after endovascular aortic repair (EVAR). Materials and Methods In this single-center prospective randomized controlled trial, individuals undergoing CTA after EVAR between August 2020 and May 2022 were allocated to imaging using either low-kilovolt single-energy images (SEI; 80 kV, group A) or low-kiloelectron volt virtual monoenergetic images (VMI) at 40 and 50 keV from multi-energy CT (80/Sn150 kV, group B). Scan protocols were dose matched (volume CT dose index: mean, 4.5 mGy ± 1.8 [SD] vs 4.7 mGy ± 1.3, P = .41). Contrast-to-noise ratio (CNR) was measured. Two expert radiologists established the reference standard for the presence of endoleaks. Detection and conspicuity of endoleaks and subjective image quality were assessed by two different blinded radiologists. Interreader agreement was calculated. Nonparametric statistical tests were used. Results A total of 125 participants (mean age, 76 years ± 8; 103 men) were allocated to groups A (n = 64) and B (n = 61). CNR was significantly lower for 40-keV VMI (mean, 19.1; P = .048) and 50-keV VMI (mean, 16.8; P < .001) as compared with SEI (mean, 22.2). In total, 45 endoleaks were present (A: 23 vs B: 22). Sensitivity for endoleak detection was higher for SEI (82.6%, 19 of 23; P = .88) and 50-keV VMI (81.8%, 18 of 22; P = .90) as compared with 40-keV VMI (77.3%, 17 of 22). Specificity was comparable among groups (SEI: 92.7%, 38 of 41; both VMI energies: 92.3%, 35 of 38; P = .99), with an interreader agreement of 1. Conspicuity of endoleaks was comparable between SEI (median, 2.99) and VMI (both energies: median, 2.87; P = .04). Overall subjective image quality was rated significantly higher for SEI (median, 4 [IQR, 4-4) as compared with 40 and 50 keV (both energies: median, 4 [IQR, 3-4]; P < .001). Conclusion SEI demonstrated higher image quality and comparable diagnostic accuracy as compared with 50-keV VMI for endoleak detection at CTA after EVAR. Keywords: Aneurysms, CT, CT Angiography, Vascular, Aorta, Technology Assessment, Multidetector CT, Abdominal Aortic Aneurysms, Endoleaks, Perigraft Leak Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Angiografia por Tomografia Computadorizada , Endoleak , Idoso , Humanos , Masculino , Aorta , Endoleak/diagnóstico por imagem , Fenômenos Físicos , Estudos Prospectivos , Feminino
11.
Artigo em Inglês | MEDLINE | ID: mdl-38389028

RESUMO

To intra-individually investigate the variation of coronary artery calcium (CAC), aortic valve calcium (AVC), and mitral annular calcium (MAC) scores and the presence of blur artifacts as a function of temporal resolution in patients undergoing non-contrast cardiac CT on a dual-source photon counting detector (PCD) CT. This retrospective, IRB-approved study included 70 patients (30 women, 40 men, mean age 78 ± 9 years) who underwent ECG-gated cardiac non-contrast CT with PCD-CT (gantry rotation time 0.25 s) prior to transcatheter aortic valve replacement. Each scan was reconstructed at a temporal resolution of 66 ms using the dual-source information and at 125 ms using the single-source information. Average heart rate and heart rate variability were calculated from the recorded ECG. CAC, AVC, and MAC were quantified according to the Agatston method on images with both temporal resolutions. Two readers assessed blur artifacts using a 4-point visual grading scale. The influence of average heart rate and heart rate variability on calcium quantification and blur artifacts of the respective structures were analyzed by linear regression analysis. Mean heart rate and heart rate variability during data acquisition were 76 ± 17 beats per minute (bpm) and 4 ± 6 bpm, respectively. CAC scores were smaller on 66 ms (median, 511; interquartile range, 220-978) than on 125 ms reconstructions (538; 203-1050, p < 0.001). Median AVC scores [2809 (2009-3952) versus 3177 (2158-4273)] and median MAC scores [226 (0-1284) versus 251 (0-1574)] were also significantly smaller on 66ms than on 125ms reconstructions (p < 0.001). Reclassification of CAC and AVC risk categories occurred in 4% and 11% of cases, respectively, whereby the risk category was always overestimated on 125ms reconstructions. Image blur artifacts were significantly less on 66ms as opposed to 125 ms reconstructions (p < 0.001). Intra-individual analyses indicate that temporal resolution significantly impacts on calcium scoring with cardiac CT, with CAC, MAC, and AVC being overestimated at lower temporal resolution because of increased motion artifacts eventually leading to an overestimation of patient risk.

12.
Eur Radiol ; 34(3): 1716-1723, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37644149

RESUMO

OBJECTIVES: To introduce an automated computational algorithm that estimates the global noise level across the whole imaging volume of PET datasets. METHODS: [18F]FDG PET images of 38 patients were reconstructed with simulated decreasing acquisition times (15-120 s) resulting in increasing noise levels, and with block sequential regularized expectation maximization with beta values of 450 and 600 (Q.Clear 450 and 600). One reader performed manual volume-of-interest (VOI) based noise measurements in liver and lung parenchyma and two readers graded subjective image quality as sufficient or insufficient. An automated computational noise measurement algorithm was developed and deployed on the whole imaging volume of each reconstruction, delivering a single value representing the global image noise (Global Noise Index, GNI). Manual noise measurement values and subjective image quality gradings were compared with the GNI. RESULTS: Irrespective of the absolute noise values, there was no significant difference between the GNI and manual liver measurements in terms of the distribution of noise values (p = 0.84 for Q.Clear 450, and p = 0.51 for Q.Clear 600). The GNI showed a fair to moderately strong correlation with manual noise measurements in liver parenchyma (r = 0.6 in Q.Clear 450, r = 0.54 in Q.Clear 600, all p < 0.001), and a fair correlation with manual noise measurements in lung parenchyma (r = 0.52 in Q.Clear 450, r = 0.33 in Q.Clear 600, all p < 0.001). Classification performance of the GNI for subjective image quality was AUC 0.898 for Q.Clear 450 and 0.919 for Q.Clear 600. CONCLUSION: An algorithm provides an accurate and meaningful estimation of the global noise level encountered in clinical PET imaging datasets. CLINICAL RELEVANCE STATEMENT: An automated computational approach that measures the global noise level of PET imaging datasets may facilitate quality standardization and benchmarking of clinical PET imaging within and across institutions. KEY POINTS: • Noise is an important quantitative marker that strongly impacts image quality of PET images. • An automated computational noise measurement algorithm provides an accurate and meaningful estimation of the global noise level encountered in clinical PET imaging datasets. • An automated computational approach that measures the global noise level of PET imaging datasets may facilitate quality standardization and benchmarking as well as protocol harmonization.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons , Humanos , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Fluordesoxiglucose F18 , Fígado/diagnóstico por imagem , Algoritmos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Imagens de Fantasmas
14.
Front Psychiatry ; 14: 1258272, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38076700

RESUMO

Background: Switzerland ranks among the top three healthcare systems in the world with regards to healthcare access, suggesting a high degree of health equity. However, Switzerland has few preventive strategies against smoking abuse. The aim of this study is to clarify whether educational level and citizenship status have an influence on the prevalence of smoking in Switzerland and whether there is health inequity related to a lack of preventive strategies. Methods: We based our analysis on publicly available health data published in the Swiss government's Swiss health survey (1992-2017). We compared the prevalence of smoking across the years and correlated these data with levels of educational attainment, citizenship status and age. Results: A continuous significant decline in smokers is observed in the highest education group (TERT). Over time, prevalence was reduced from 29% in 1992 to 23% in 2017 (p < 0.001). The intermediate-level educational group (SEK 2) showed smaller but also significant decline on a 0.05 sigificance level over the same period, from 31% to 29% (p = 0.003). The lowest educational group showed a nonsignificant decline from 28% to 27% (p = 0.6). The population who holds Swiss citizenship showed a decrease in smoking from 28% to 26% within the time frame (p < 0.001). People without Swiss citizenship had a much higher prevalence of smokers, at 38% in 1992 and declining to 32% in 2017 (p < 0.001). All cohorts from age 15 to age 64 have a far higher prevalence of smokers than cohorts at an older age, with the highest prevalence in the 25-34 age group. Conclusion: In Switzerland, individuals with lower levels of education and non-Swiss populations are more susceptible to health risk of smoking. This is despite the existence of a high-quality healthcare system that has nevertheless failed to negated health inequities.

15.
Cancers (Basel) ; 15(23)2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-38067274

RESUMO

Transthoracic esophagectomy results in a radical change in foregut anatomy with multiple consequences for digestive physiology. The aim of this study was to identify factors associated with poor functional outcomes by assessing multiple dimensions of digestive performance and health-related quality of life (HRQL). Patients with cancer-free survival after Ivor Lewis esophagectomy were included. Four functional syndromes (dysphagia, gastroesophageal reflux disease (GERD), delayed gastric conduit emptying (DGCE), and dumping syndrome (DS)) and HRQL were assessed using specifically designed questionnaires. Patient outcomes were compared with healthy controls. Independent factors associated with poor digestive performance were identified through multivariable analysis. Sixty-five postoperative patients and 50 healthy volunteers participated in this study. Compared with controls, patients had worse outcomes for dysphagia, GERD, DS, and HRQL, but not for DGCE. A multivariate analysis showed a significant correlation of reduced digestive performance with ASA score, squamous cell carcinoma, open or hybrid surgical approach, and (neo)adjuvant therapy. In contrast, no individual patient factor was found to be associated with dumping syndrome. Digestive function and HRQL are substantially impaired after Ivor Lewis esophagectomy for cancer. Comorbid patients undergoing multimodal treatment and open access surgery for squamous cell carcinoma have the highest risk of poor functional outcome.

16.
Sci Rep ; 13(1): 18847, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37914764

RESUMO

The purpose of this retrospective study was to investigate response of sinonasal mucosal melanoma (SMM) patients to treatment with immune checkpoint inhibitors (ICI), using hybrid PET imaging. Fifteen SMM patients underwent hybrid PET imaging before and three months after initiation of ICI. The disease-specific survival (DSS) was calculated. Quantitative PET parameters of the primary tumor and their association with DSS and therapy response were investigated. Nine of the fifteen (60%) patients responded to ICI therapy. Patients with therapy response depicted on hybrid PET imaging had better DSS than those without (p = 0.0058). Quantitative PET parameters of the initial PET harbored no association with DSS or therapy response. However, these findings lack of sufficient statistical power and must be interpreted with caution. The first restaging PET-imaging after ICI initiation can help stratify patients with regard to DSS.


Assuntos
Melanoma , Neoplasias dos Seios Paranasais , Humanos , Inibidores de Checkpoint Imunológico/farmacologia , Inibidores de Checkpoint Imunológico/uso terapêutico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Estudos Retrospectivos , Melanoma/diagnóstico por imagem , Melanoma/tratamento farmacológico , Melanoma/patologia , Tomografia por Emissão de Pósitrons , Neoplasias dos Seios Paranasais/patologia , Fluordesoxiglucose F18
17.
PLoS One ; 18(11): e0291007, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37939048

RESUMO

INTRODUCTION: A trend towards less male radiologists specializing in breast ultrasound was observed. A common notion in the field of breast radiology is, that female patients feel more comfortable being treated by female radiologists. The aim of the study was to understand and report the needs of women undergoing breast ultrasound with regards to the sex of the radiologist performing the investigation. METHODS: Informed consent was obtained from all patients prior to inclusion in a prospective bi-center quality study. At center 1 (72 patients), the women were examined exclusively by female radiologists, at center 2 (100 patients) only by male radiologists. After the examination the patients were asked about their experiences and their wishes for the future. RESULTS: Overall, women made no distinction between female and male radiologists; 25% of them wanted a female radiologist and 1.2% wanted a male radiologist. The majority (74%) stated that it made no difference whether a female or male radiologist performed the examination. The majority of women in group 2, who were investigated exclusively by male radiologists, stated that they had no preferences with regard to the sex of the radiologist (93%); 5% of the women wished to be investigated solely by a female radiologist and 2% exclusively by a male radiologist. DISCUSSION: The majority of women undergoing breast ultrasound are unconcerned about the radiologist's sex. It would appear that women examined by male radiologists are less selective about the sex of the examining radiologist. TRIAL REGISTRATION: Written informed consent was obtained from all patients. All patient data were anonymized. The physicians had no access to any further personal data. National regulations did not require dedicated ethics approval with anonymized lists or retrospective questionnaires.


Assuntos
Neoplasias da Mama , Médicos , Humanos , Feminino , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Radiologistas , Ultrassonografia Mamária
18.
Eur Radiol ; 2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37855853

RESUMO

OBJECTIVES: To assess the evolution of administered radiotracer activity for F-18-fluorodeoxyglucose (18F-FDG) PET/CT or PET/MR in pediatric patients (0-16 years) between years 2000 and 2021. METHODS: Pediatric patients (≤ 16 years) referred for 18F-FDG PET/CT or PET/MR imaging of the body during 2000 and 2021 were retrospectively included. The amount of administered radiotracer activity in megabecquerel (MBq) was recorded, and signal-to-noise ratio (SNR) was measured in the right liver lobe with a 4 cm3 volume of interest as an indicator for objective image quality. Descriptive statistics were computed. RESULTS: Two hundred forty-three children and adolescents underwent a total of 466 examinations. The median injected 18F-FDG activity in MBq decreased significantly from 296 MBq in 2000-2005 to 100 MBq in 2016-2021 (p < 0.001), equaling approximately one-third of the initial amount. The median SNR ratio was stable during all years with 11.7 (interquartile range [IQR] 10.7-12.9, p = 0.133). CONCLUSIONS: Children have benefited from a massive reduction in the administered 18F-FDG dose over the past 20 years without compromising objective image quality. CLINICAL RELEVANCE STATEMENT: Radiotracer dose was reduced considerably over the past two decades of pediatric F-18-fluorodeoxyglucose PET/CT and PET/MR imaging highlighting the success of technical innovations in pediatric PET imaging. KEY POINTS: • The evolution of administered radiotracer activity for F-18-fluorodeoxyglucose (18F-FDG) PET/CT or PET/MR in pediatric patients (0-16 years) between 2000 and 2021 was assessed. • The injected tracer activity decreased by 66% during the study period from 296 megabecquerel (MBq) to 100 MBq (p < 0.001). • The continuous implementation of technical innovations in pediatric hybrid 18F-FDG PET has led to a steady decrease in the amount of applied radiotracer, which is particularly beneficial for children who are more sensitive to radiation.

19.
Sci Rep ; 13(1): 18357, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-37884535

RESUMO

This study aimed to evaluate the diagnostic accuracy of Node Reporting and Data System (Node-RADS) in discriminating between normal, reactive, and metastatic axillary LNs in patients with melanoma who underwent SARS-CoV-2 vaccination. Patients with proven melanoma who underwent a 2-[18F]-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (2-[18F]-FDG PET/CT) between February and April 2021 were included in this retrospective study. Primary melanoma site, vaccination status, injection site, and 2-[18F]-FDG PET/CT were used to classify axillary LNs into normal, inflammatory, and metastatic (combined classification). An adapted Node-RADS classification (A-Node-RADS) was generated based on LN anatomical characteristics on low-dose CT images and compared to the combined classification. 108 patients were included in the study (54 vaccinated). HALNs were detected in 42 patients (32.8%), of whom 97.6% were vaccinated. 172 LNs were classified as normal, 30 as inflammatory, and 14 as metastatic using the combined classification. 152, 22, 29, 12, and 1 LNs were classified A-Node-RADS 1, 2, 3, 4, and 5, respectively. Hence, 174, 29, and 13 LNs were deemed benign, equivocal, and metastatic. The concordance between the classifications was very good (Cohen's k: 0.91, CI 0.86-0.95; p-value < 0.0001). A-Node-RADS can assist the classification of axillary LNs in melanoma patients who underwent 2-[18F]-FDG PET/CT and SARS-CoV-2 vaccination.


Assuntos
COVID-19 , Melanoma , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Vacinas contra COVID-19 , SARS-CoV-2 , Fluordesoxiglucose F18 , Estudos Retrospectivos , Estadiamento de Neoplasias , Metástase Linfática/patologia , COVID-19/diagnóstico por imagem , COVID-19/patologia , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Melanoma/diagnóstico por imagem , Melanoma/patologia , Vacinação , Compostos Radiofarmacêuticos
20.
Br J Radiol ; 96(1152): 20220482, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37751216

RESUMO

OBJECTIVES: To evaluate the evolution of CT radiation dose in pediatric patients undergoing hybrid 2-[18F]fluoro-2-deoxy-D-glucose (2-[18F]FDG) PET/CT between 2007 and 2021. METHODS AND MATERIALS: Data from all pediatric patients aged 0-18 years who underwent hybrid 2-[18F]FDG PET/CT of the body between January 2007 and May 2021 were reviewed. Demographic and imaging parameters were collected. A board-certified radiologist reviewed all CT scans and measured image noise in the brain, liver, and adductor muscles. RESULTS: 294 scans from 167 children (72 females (43%); median age: 14 (IQR 10-15) years; BMI: median 17.5 (IQR 15-20.4) kg/m2) were included. CT dose index-volume (CTDIvol) and dose length product (DLP) both decreased significantly from 2007 to 2021 (both p < 0.001, Spearman's rho coefficients -0.46 and -0.35, respectively). Specifically, from 2007 to 2009 to 2019-2021 CTDIvol and DLP decreased from 2.94 (2.14-2.99) mGy and 309 (230-371) mGy*cm, respectively, to 0.855 (0.568-1.11) mGy and 108 (65.6-207) mGy*cm, respectively. From 2007 to 2021, image noise in the brain and liver remained constant (p = 0.26 and p = 0.06), while it decreased in the adductor muscles (p = 0.007). Peak tube voltage selection (in kilovolt, kV) of CT scans shifted from high kV imaging (140 or 120kVp) to low kV imaging (100 or 80kVp) (p < 0.001) from 2007 to 2021. CONCLUSION: CT radiation dose in pediatric patients undergoing hybrid 2-[18F]FDG PET/CT has decreased in recent years equaling approximately one-third of the initial amount. ADVANCES IN KNOWLEDGE: Over the past 15 years, CT radiation dose decreased considerably in pediatric patients undergoing hybrid imaging, while objective image quality may not have been compromised.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Feminino , Humanos , Criança , Adolescente , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Encéfalo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA