Med Phys ; 51(10): 7119-7126, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39172134

RESUMO

BACKGROUND: Breathing signal-guided 4D CT sequence scanning such as the intelligent 4D CT (i4DCT) approach reduces imaging artifacts compared to conventional 4D CT. By design, i4DCT captures entire breathing cycles during beam-on periods, leading to redundant projection data and increased radiation exposure to patients exhibiting prolonged exhalation phases. A recently proposed breathing-guided dose modulation (DM) algorithm promises to lower the imaging dose by temporarily reducing the CT tube current, but the impact on image reconstruction and the resulting images have not been investigated. PURPOSE: We evaluate the impact of breathing signal-guided DM on 4D CT image reconstruction and corresponding images. METHODS: This study is designed as a comparative and retrospective analysis based on 104 4D CT datasets. Each dataset underwent retrospective reconstruction twice: (a) utilizing the acquired clinical projection data for reconstruction, which yields reference image data, and (b) excluding projections acquired during potential DM phases from image reconstruction, resulting in DM-affected image data. Resulting images underwent automatic organ segmentation (lung/liver). (Dis)Similarity of reference and DM-affected images were quantified by the Dice coefficient of the entire organ masks and the organ overlaps within the DM-affected slices. Further, for lung cases, (a) and (b) were deformably registered and median magnitudes of the obtained displacement field were computed. Eventually, for 17 lung cases, gross tumor volumes (GTV) were recontoured on both (a) and (b). Target volume similarity was quantified by the Hausdorff distance. RESULTS: DM resulted in a median imaging dose reduction of 15.4% (interquartile range [IQR]: 11.3%-19.9%) for the present patient cohort. Dice coefficients for lung ( n = 73 $n=73$ ) and liver ( n = 31 $n=31$ ) patients were consistently high for both the entire organs and the DM-affected slices (IQR lung: 0.985 / 0.982 $0.985/0.982$ [entire lung/DM-affected slices only] to 0.992 / 0.989 $0.992/0.989$ ; IQR liver: 0.977 / 0.972 $0.977/0.972$ to 0.986 / 0.986 $0.986/0.986$ ), demonstrating that DM did not cause organ distortions or alterations. Median displacements for DM-affected to reference image registration varied; however, only two out of 73 cases exhibited a median displacement larger than one isotropic 1 mm 3 ${\rm mm}^3$ voxel size. The impact on GTV definition for the end-exhalation phase was also minor (median Hausdorff distance: 0.38 mm, IQR: 0.15-0.46 mm). CONCLUSION: This study demonstrates that breathing signal-guided DM has a minimal impact on image reconstruction and image appearance while improving patient safety by reducing dose exposure.


Assuntos
Tomografia Computadorizada Quadridimensional , Processamento de Imagem Assistida por Computador , Doses de Radiação , Respiração , Humanos , Tomografia Computadorizada Quadridimensional/métodos , Processamento de Imagem Assistida por Computador/métodos , Estudos Retrospectivos , Pulmão/diagnóstico por imagem , Algoritmos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Artefatos
2.
Med Phys ; 50(12): 7539-7547, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37831550

RESUMO

BACKGROUND: Respiratory signal-guided 4D CT sequence scanning such as the recently introduced Intelligent 4D CT (i4DCT) approach reduces image artifacts compared to conventional 4D CT, especially for irregular breathing. i4DCT selects beam-on periods during scanning such that data sufficiency conditions are fulfilled for each couch position. However, covering entire breathing cycles during beam-on periods leads to redundant projection data and unnecessary dose to the patient during long exhalation phases. PURPOSE: We propose and evaluate the feasibility of respiratory signal-guided dose modulation (i.e., temporary reduction of the CT tube current) to reduce the i4DCT imaging dose while maintaining high projection data coverage for image reconstruction. METHODS: The study is designed as an in-silico feasibility study. Dose down- and up-regulation criteria were defined based on the patients' breathing signals and their representative breathing cycle learned before and during scanning. The evaluation (including an analysis of the impact of the dose modulation criteria parameters) was based on 510 clinical 4D CT breathing curves. Dose reduction was determined as the fraction of the downregulated dose delivery time to the overall beam-on time. Furthermore, under the assumption of a 10-phase 4D CT and amplitude-based reconstruction, beam-on periods were considered negatively affected by dose modulation if the downregulation period covered an entire phase-specific amplitude range for a specific breathing phase (i.e., no appropriate reconstruction of the phase image possible for this specific beam-on period). Corresponding phase-specific amplitude bins are subsequently denoted as compromised bins. RESULTS: Dose modulation resulted in a median dose reduction of 10.4% (lower quartile: 7.4%, upper quartile: 13.8%, maximum: 28.6%; all values corresponding to a default parameterization of the dose modulation criteria). Compromised bins were observed in 1.0% of the beam-on periods (72 / 7370 periods) and affected 10.6% of the curves (54/510 curves). The extent of possible dose modulation depends strongly on the individual breathing patterns and is weakly correlated with the median breathing cycle length (Spearman correlation coefficient 0.22, p < 0.001). Moreover, the fraction of beam-on periods with compromised bins is weakly anti-correlated with the patient's median breathing cycle length (Spearman correlation coefficient -0.24; p < 0.001). Among the curves with the 17% longest average breathing cycles, no negatively affected beam-on periods were observed. CONCLUSION: Respiratory signal-guided dose modulation for i4DCT imaging is feasible and promises to significantly reduce the imaging dose with little impact on projection data coverage. However, the impact on image quality remains to be investigated in a follow-up study.


Assuntos
Tomografia Computadorizada Quadridimensional , Neoplasias Pulmonares , Humanos , Tomografia Computadorizada Quadridimensional/métodos , Estudos de Viabilidade , Redução da Medicação , Seguimentos , Respiração
3.
Phys Imaging Radiat Oncol ; 20: 56-61, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34786496

RESUMO

BACKGROUND AND PURPOSE: Four-dimensional computed tomography (4DCT) has become an essential part of radiotherapy planning but is often affected by artifacts. A new breathing controlled 4DCT (i4DCT) algorithm has been introduced. This study aims to present the first clinical data and to evaluate the achieved image quality, projection data coverage and beam-on time. MATERIAL & METHODS: The analysis included i4DCT data for 129 scans of patients with thoracic tumors. Projection data coverage and beam-on time were evaluated. Additionally, image quality was exemplarily discussed and rated by ten clinical experts with a 5-score-scale for 30 patients with large variations in their breathing pattern ('challenging subgroup'). Rated images were reconstructed amplitude- and phase-based. RESULTS: Expert scoring revealed that 78% (amplitude-based) and 63% (phase-based) of the challenging subgroup were artifact-free (rating ≥4). For the entire cohort, average beam-on time per couch position was 4.9 ± 1.6 s. For the challenging subgroup, time increased slightly but not significantly compared to the remaining patients (5.1 s vs. 4.9 s; p = 0.64). Median projection data coverage was 93% and 94% for inhalation and exhalation, respectively, for the entire cohort. The comparison for the subgroup and the remaining patients revealed a small but significant decrease of the median coverage values for the challenging cases (inhalation: 90% vs. 94%, p = 0.02; exhalation: 93% vs. 94%, p = 0.02). CONCLUSIONS: This first clinical evaluation of i4DCT shows very promising results in terms of image quality and projection data coverage. The results agree with and support the results of previous i4DCT phantom studies.

4.
Phys Med Biol ; 66(1)2021 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-33171441

RESUMO

4D CT imaging is a cornerstone of 4D radiotherapy treatment. Clinical 4D CT data are, however, often affected by severe artifacts. The artifacts are mainly caused by breathing irregularity and retrospective correlation of breathing phase information and acquired projection data, which leads to insufficient projection data coverage to allow for proper reconstruction of 4D CT phase images. The recently introduced 4D CT approach i4DCT (intelligent 4D CT sequence scanning) aims to overcome this problem by breathing signal-driven tube control. The present motion phantom study describes the first in-depth evaluation of i4DCT in a real-world scenario. Twenty-eight 4D CT breathing curves of lung and liver tumor patients with pronounced breathing irregularity were selected to program the motion phantom. For every motion pattern, 4D CT imaging was performed with i4DCT and a conventional spiral 4D CT mode. For qualitative evaluation, the reconstructed 4D CT images were presented to clinical experts, who scored image quality. Further quantitative evaluation was based on established image intensity-based artifact metrics to measure (dis)similarity of neighboring image slices. In addition, beam-on and scan times of the scan modes were analyzed. The expert rating revealed a significantly higher image quality for the i4DCT data. The quantitative evaluation further supported the qualitative: While 20% of the slices of the conventional spiral 4D CT images were found to be artifact-affected, the corresponding fraction was only 4% for i4DCT. The beam-on time (surrogate of imaging dose) did not significantly differ between i4DCT and spiral 4D CT. Overall i4DCT scan times (time between first beam-on and last beam-on event, including scan breaks to compensate for breathing irregularity) were, on average, 53% longer compared to spiral CT. Thus, the results underline that i4DCT significantly improves 4D CT image quality compared to standard spiral CT scanning in the case of breathing irregularity during scanning.


Assuntos
Tomografia Computadorizada Quadridimensional , Tomografia Computadorizada Espiral , Tomografia Computadorizada Quadridimensional/métodos , Humanos , Imagens de Fantasmas , Respiração , Estudos Retrospectivos , Tomografia Computadorizada Espiral/métodos
5.
Med Phys ; 47(6): 2408-2412, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32115724

RESUMO

PURPOSE: Four-dimensional (4D) computed tomography (CT) imaging is an essential part of current 4D radiotherapy treatment planning workflows, but clinical 4D CT images are often affected by artifacts. The artifacts are mainly caused by breathing irregularity during data acquisition, which leads to projection data coverage issues for currently available commercial 4D CT protocols. It was proposed to improve projection data coverage by online respiratory signal analysis and signal-guided CT tube control, but related work was always theoretical and presented as pure in silico studies. The present work demonstrates a first CT prototype implementation along with respective phantom measurements for the recently introduced intelligent 4D CT (i4DCT) sequence scanning concept (https://doi.org/10.1002/mp.13632). METHODS: Intelligent 4D CT was implemented on the Siemens SOMATOM go platform. Four-dimensional CT measurements were performed using the CIRS motion phantom. Motion curves were programmed to systematically vary from regular to very irregular, covering typical irregular patterns that are known to result in image artifacts using standard 4D CT imaging protocols. Corresponding measurements were performed using i4DCT and routine spiral 4D CT with similar imaging parameters (e.g., mAs setting and gantry rotation time, retrospective ten-phase reconstruction) to allow for a direct comparison of the image data. RESULTS: Following technological implementation of i4DCT on the clinical CT scanner platform, 4D CT motion artifacts were significantly reduced for all investigated levels of breathing irregularity when compared to routine spiral 4D CT scanning. CONCLUSIONS: The present study confirms feasibility of fully automated respiratory signal-guided 4D CT scanning by means of a first implementation of i4DCT on a CT scanner. The measurements thereby support the conclusions of respective in silico studies and demonstrate that respiratory signal-guided 4D CT (here: i4DCT) is ready for integration into clinical CT scanners.


Assuntos
Tomografia Computadorizada Quadridimensional , Neoplasias Pulmonares , Artefatos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Imagens de Fantasmas , Respiração , Estudos Retrospectivos