Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 132
Filtrar
1.
Chem Rev ; 124(10): 6543-6591, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38728658

RESUMO

Bioelectronics integrates electronics with biological organs, sustaining the natural functions of the organs. Organs dynamically interact with the external environment, managing internal equilibrium and responding to external stimuli. These interactions are crucial for maintaining homeostasis. Additionally, biological organs possess a soft and stretchable nature; encountering objects with differing properties can disrupt their function. Therefore, when electronic devices come into contact with biological objects, the permeability of these devices, enabling interactions and substance exchanges with the external environment, and the mechanical compliance are crucial for maintaining the inherent functionality of biological organs. This review discusses recent advancements in soft and permeable bioelectronics, emphasizing materials, structures, and a wide range of applications. The review also addresses current challenges and potential solutions, providing insights into the integration of electronics with biological organs.


Assuntos
Eletrônica , Humanos , Permeabilidade , Dispositivos Eletrônicos Vestíveis , Animais
2.
Nat Commun ; 15(1): 4474, 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38796514

RESUMO

Olfaction feedback systems could be utilized to stimulate human emotion, increase alertness, provide clinical therapy, and establish immersive virtual environments. Currently, the reported olfaction feedback technologies still face a host of formidable challenges, including human perceivable delay in odor manipulation, unwieldy dimensions, and limited number of odor supplies. Herein, we report a general strategy to solve these problems, which associates with a wearable, high-performance olfactory interface based on miniaturized odor generators (OGs) with advanced artificial intelligence (AI) algorithms. The OGs serve as the core technology of the intelligent olfactory interface, which exhibit milestone advances in millisecond-level response time, milliwatt-scale power consumption, and the miniaturized size. Empowered by robust AI algorithms, the olfactory interface shows its great potentials in latency-free mixed reality (MR) and fast olfaction enhancement, thereby establishing a bridge between electronics and users for broad applications ranging from entertainment, to education, to medical treatment, and to human machine interfaces.


Assuntos
Algoritmos , Inteligência Artificial , Odorantes , Olfato , Dispositivos Eletrônicos Vestíveis , Humanos , Olfato/fisiologia , Interface Usuário-Computador , Adulto , Masculino
3.
ACS Appl Mater Interfaces ; 16(21): 27065-27074, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38748094

RESUMO

Wearable biomedical sensors have enabled noninvasive and continuous physiological monitoring for daily health management and early detection of chronic diseases. Among biomedical sensors, wearable pH sensors attracted significant interest, as pH influences most biological reactions. However, conformable pH sensors that have sweat absorption ability, are self-adhesive to the skin, and are gas permeable remain largely unexplored. In this study, we present a pioneering approach to this problem by developing a Janus membrane-based pH sensor with self-adhesiveness on the skin. The sensor is composed of a hydrophobic polyurethane-polydimethylsiloxane porous hundreds nanometer-thick substrate and a hydrophilic poly(vinyl alcohol)-poly(acrylic acid) porous nanofiber layer. This Janus membrane exhibits a thickness of around 10 µm, providing a conformable adhesion to the skin. The simultaneous realization of solution absorption, gas permeability, and self-adhesiveness makes it suitable for long-term continuous monitoring without compromising the comfort of the wearer. The pH sensor was tested successfully for continuous monitoring for 7.5 h, demonstrating its potential for stable analysis of skin health conditions. The Janus membrane-based pH sensor holds significant promise for comprehensive skin health monitoring and wearable biomedical applications.


Assuntos
Poliuretanos , Suor , Dispositivos Eletrônicos Vestíveis , Concentração de Íons de Hidrogênio , Humanos , Suor/química , Poliuretanos/química , Permeabilidade , Resinas Acrílicas/química , Membranas Artificiais , Dimetilpolisiloxanos/química , Adesividade , Nanofibras/química , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/instrumentação , Porosidade , Gases/química , Gases/análise
4.
Sci Rep ; 14(1): 9953, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38688993

RESUMO

Improving the energy efficiency of robots remains a crucial challenge in soft robotics, with energy harvesting emerging as a promising approach to address it. This study presents a functional soft robotic composite called OPV-DEA, which integrates flexible organic photovoltaic (OPV) and dielectric elastomer actuator (DEA). The composite can simultaneously generate electrostatic bending actuation and harvest energy from external lights. Owing to its simplicity and inherent flexibility, the OPV-DEA is poised to function as a fundamental building block for soft robots. This study aimed to validate this concept by initially establishing the fabrication process of OPV-DEA. Subsequently, experimental samples are fabricated and characterized. The results show that the samples exhibit a voltage-controllable bending actuation of up to 15.6° and harvested power output of 1.35 mW under an incident power irradiance of 11.7 mW/cm2. These performances remain consistent even after 1000 actuation cycles. Finally, to demonstrate the feasibility of soft robotic applications, an untethered swimming robot equipped with two OPV-DEAs is fabricated and tested. The robot demonstrates swimming at a speed of 21.7 mm/s. The power consumption of the robot is dominated by a high-voltage DC-DC converter, with a value approximately 1.5 W. As a result, the on-board OPVs cannot supply the necessary energy during locomotion simultaneously. Instead, they contribute to the overall system by charging a battery used for the controller on board. Nevertheless, these findings suggest that the OPV-DEA could pave the way for the development of an unprecedented range of functional soft robots.

5.
Sci Adv ; 10(15): eadk9460, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38598623

RESUMO

All-solution-processed organic optoelectronic devices can enable the large-scale manufacture of ultrathin wearable electronics with integrated diverse functions. However, the complex multilayer-stacking device structure of organic optoelectronics poses challenges for scalable production. Here, we establish all-solution processes to fabricate a wearable, self-powered photoplethysmogram (PPG) sensor. We achieve comparable performance and improved stability compared to complex reference devices with evaporated electrodes by using a trilayer device structure applicable to organic photovoltaics, photodetectors, and light-emitting diodes. The PPG sensor array based on all-solution-processed organic light-emitting diodes and photodetectors can be fabricated on a large-area ultrathin substrate to achieve long storage stability. We integrate it with a large-area, all-solution-processed organic solar module to realize a self-powered health monitoring system. We fabricate high-throughput wearable electronic devices with complex functions on large-area ultrathin substrates based on organic optoelectronics. Our findings can advance the high-throughput manufacture of ultrathin electronic devices integrating complex functions.

6.
Nat Commun ; 15(1): 681, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38302472

RESUMO

Ultraflexible organic photovoltaics have emerged as a potential power source for wearable electronics owing to their stretchability and lightweight nature. However, waterproofing ultraflexible organic photovoltaics without compromising mechanical flexibility and conformability remains challenging. Here, we demonstrate waterproof and ultraflexible organic photovoltaics through the in-situ growth of a hole-transporting layer to strengthen interface adhesion between the active layer and anode. Specifically, a silver electrode is deposited directly on top of the active layers, followed by thermal annealing treatment. Compared with conventional sequentially-deposited hole-transporting layers, the in-situ grown hole-transporting layer exhibits higher thermodynamic adhesion between the active layers, resulting in better waterproofness. The fabricated 3 µm-thick organic photovoltaics retain 89% and 96% of their pristine performance after immersion in water for 4 h and 300 stretching/releasing cycles at 30% strain under water, respectively. Moreover, the ultraflexible devices withstand a machine-washing test with such a thin encapsulation layer, which has never been reported. Finally, we demonstrate the universality of the strategy for achieving waterproof solar cells.

7.
Nat Commun ; 15(1): 1115, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38321015

RESUMO

The current challenge of wearable/implantable personal dosimeters for medical diagnosis and radiotherapy applications is lack of suitable detector materials possessing both excellent detection performance and biocompatibility. Here, we report a solution-grown biocompatible organic single crystalline semiconductor (OSCS), 4-Hydroxyphenylacetic acid (4HPA), achieving real-time spectral detection of charged particles with single-particle sensitivity. Along in-plane direction, two-dimensional anisotropic 4HPA exhibits a large electron drift velocity of 5 × 105 cm s-1 at "radiation-mode" while maintaining a high resistivity of (1.28 ± 0.003) × 1012 Ω·cm at "dark-mode" due to influence of dense π-π overlaps and high-energy L1 level. Therefore, 4HPA detectors exhibit the record spectra detection of charged particles among their organic counterparts, with energy resolution of 36%, (µt)e of (4.91 ± 0.07) × 10-5 cm2 V-1, and detection time down to 3 ms. These detectors also show high X-ray detection sensitivity of 16,612 µC Gyabs-1 cm-3, detection of limit of 20 nGyair s-1, and long-term stability after 690 Gyair irradiation.

8.
Sci Adv ; 10(2): eadj5389, 2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38198560

RESUMO

Hydrogel-enabled skin bioelectronics that can continuously monitor health for extended periods is crucial for early disease detection and treatment. However, it is challenging to engineer ultrathin gas-permeable hydrogel sensors that can self-adhere to the human skin for long-term daily use (>1 week). Here, we present a ~10-micrometer-thick polyurethane nanomesh-reinforced gas-permeable hydrogel sensor that can self-adhere to the human skin for continuous and high-quality electrophysiological monitoring for 8 days under daily life conditions. This research involves two key steps: (i) material design by gelatin-based thermal-dependent phase change hydrogels and (ii) robust thinness geometry achieved through nanomesh reinforcement. The resulting ultrathin hydrogels exhibit a thickness of ~10 micrometers with superior mechanical robustness, high skin adhesion, gas permeability, and anti-drying performance. To highlight the potential applications in early disease detection and treatment that leverage the collective features, we demonstrate the use of ultrathin gas-permeable hydrogels for long-term, continuous high-precision electrophysiological monitoring under daily life conditions up to 8 days.


Assuntos
Hidrogéis , Pele , Humanos , Dessecação , Engenharia , Alimentos
9.
Adv Mater ; 36(5): e2304604, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37656902

RESUMO

Self-powered skin optoelectronics fabricated on ultrathin polymer films is emerging as one of the most promising components for the next-generation Internet of Things (IoT) technology. However, a longstanding challenge is the device underperformance owing to the low process temperature of polymer substrates. In addition, broadband electroluminescence (EL) based on organic or polymer semiconductors inevitably suffers from periodic spectral distortion due to Fabry-Pérot (FP) interference upon substrate bending, preventing advanced applications. Here, ultraflexible skin optoelectronics integrating high-performance solar cells and monochromatic light-emitting diodes using solution-processed perovskite semiconductors is presented. n-i-p perovskite solar cells and perovskite nanocrystal light-emitting diodes (PNC-LEDs), with power-conversion and current efficiencies of 18.2% and 15.2 cd A-1 , respectively, are demonstrated on ultrathin polymer substrates with high thermal stability, which is a record-high efficiency for ultraflexible perovskite solar cell. The narrowband EL with a full width at half-maximum of 23 nm successfully eliminates FP interference, yielding bending-insensitive spectra even under 50% of mechanical compression. Photo-plethysmography using the skin optoelectronic device demonstrates a signal selectivity of 98.2% at 87 bpm pulse. The results presented here pave the way to inexpensive and high-performance ultrathin optoelectronics for self-powered applications such as wearable displays and indoor IoT sensors.

10.
Sci Adv ; 9(36): eadi2445, 2023 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-37683001

RESUMO

Multipoint 3-axis tactile pressure sensing by a high-resolution and sensitive optical system provides rich information on surface pressure distribution and plays an important role in a variety of human interaction-related and robotics applications. However, the optical system usually has a bulky profile, which brings difficulties to sensor mounting and system integration. Here, we show a construction of thin-film and flexible multipoint 3-axis pressure sensor by optical methods. The sensor can detect the distribution of 3-axis pressure on an area of 3 centimeter by 4 centimeter, with a high-accuracy normal and tangential pressure sensing up to 360 and 100 kilopascal, respectively. A porous rubber is used as a 3-axis pressure-sensitive optical modulator to omit the thick and rigid focusing system without sacrificing the sensitivity. In addition, by integrating thin and flexible backlight and imager, the sensor has a total thickness of 1.5 milimeter, making it function properly even when bent to a radius of 18 milimeter.

11.
ACS Appl Mater Interfaces ; 15(17): 21314-21323, 2023 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-37084756

RESUMO

Organic photovoltaics (OPVs) have unique advantages of low weight, mechanical flexibility, and solution processability, which make them exceptionally suitable for integrating low-power Internet of Things devices. However, achieving improved operational stability together with solution processes that are applicable to large-scale fabrication remains challenging. Their major limitation arises due to the instable factors that occur both inside the thick active film and from the ambient environment, which cannot be completely resolved via the current encapsulation techniques used for flexible OPVs. Additionally, thin active layers are highly vulnerable to point defects, which result in low yield rates and impede the laboratory-to-industry translation. In this study, flexible fully solution-processed OPVs with improved indoor efficiency and long-term operational stability than that of conventional OPVs with evaporated electrodes are achieved. Benefiting from the oxygen and water vapor permeation barrier of the spontaneously formed gallium oxide layers on the exposed eutectic gallium-indium surface, fast degradation of the OPVs with thick active layers is prevented, maintaining 93% of its initial Pmax after 5000 min of indoor operation under 1000 lx light-emitting diode (LED) illumination. Additionally, by using the thick active layer, spin-coated silver nanowires could be directly used as bottom electrodes without complicated flattening processes, thereby substantially simplifying the fabrication process and proposing a promising manufacturing technique for devices with high-throughput energy demands.

12.
Artigo em Inglês | MEDLINE | ID: mdl-36896972

RESUMO

Insufficient interfacial adhesion is a widespread problem across multilayered devices that undermines their reliability. In flexible organic photovoltaics (OPVs), poor interfacial adhesion can accelerate degradation and failure under mechanical deformations due to the intrinsic brittleness and mismatching mechanical properties between functional layers. We introduce an argon plasma treatment for OPV devices, which yields 58% strengthening in interfacial adhesion between an active layer and a MoOX hole transport layer, thus contributing to mechanical reliability. The improved adhesion is attributed to the increased surface energy of the active layer that occurred after the mild argon plasma treatment. The mechanically stabilized interface retards the flexible device degradation induced by mechanical stress and maintains a power conversion efficiency of 94.8% after 10,000 cycles of bending with a radius of 2.5 mm. In addition, a fabricated 3 µm thick ultraflexible OPV device shows excellent mechanical robustness, retaining 91.0% of the initial efficiency after 1000 compressing-stretching cycles with a 40% compression ratio. The developed ultraflexible OPV devices can operate stably at the maximum power point under continuous 1 sun illumination for 500 min with an 89.3% efficiency retention. Overall, we validate a simple interfacial linking strategy for efficient and mechanically robust flexible and ultraflexible OPVs.

13.
ACS Appl Mater Interfaces ; 15(9): 12495-12501, 2023 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-36752719

RESUMO

Optoelectronic devices, such as photodetectors and photovoltaics, are susceptible to surface contamination or water damage that can lead to reductions in performance or stability. Applying superhydrophobic coatings to these devices can introduce self-cleaning behavior and water resistance to extend their lifetime and improve their efficiency. However, existing methods for inducing superhydrophobicity have not been compatible with ultraflexible devices because of their thickness and complexity requirements. In this work, we introduce a procedure for inducing superhydrophobic and self-cleaning behavior on ultraflexible components using a combination of shrinkage-induced wrinkles and a low-surface-energy coating. We apply these techniques to an ultraflexible organic photovoltaics and demonstrate excellent hydrophobicity and self-cleaning behavior.

14.
Adv Mater ; 35(1): e2206793, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36267034

RESUMO

On-skin electronics that offer revolutionary capabilities in personalized diagnosis, therapeutics, and human-machine interfaces require seamless integration between the skin and electronics. A common question remains whether an ideal interface can be introduced to directly bridge thin-film electronics with the soft skin, allowing the skin to breathe freely and the skin-integrated electronics to function stably. Here, an ever-thinnest hydrogel is reported that is compliant to the glyphic lines and subtle minutiae on the skin without forming air gaps, produced by a facile cold-lamination method. The hydrogels exhibit high water-vapor permeability, allowing nearly unimpeded transepidermal water loss and free breathing of the skin underneath. Hydrogel-interfaced flexible (opto)electronics without causing skin irritation or accelerated device performance deterioration are demonstrated. The long-term applicability is recorded for over one week. With combined features of extreme mechanical compliance, high permeability, and biocompatibility, the ultrathin hydrogel interface promotes the general applicability of skin-integrated electronics.


Assuntos
Eletrônica , Pele , Humanos , Metilgalactosídeos , Hidrogéis
15.
Adv Sci (Weinh) ; 9(30): e2202312, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36057993

RESUMO

Flexible sensors enable on-skin and in-body health monitoring, which require flexible thermal protection circuits to prevent overheating and operate the devices safely. Here, ultrathin fiber-mesh polymer positive temperature coefficient (PTC) thermistors via electrospinning are developed. The fiber-type thermistors are composed of acrylate polymer and carbon nanofibers. The fibrous composite materials are coated with a parylene to form a core-sheath structure, which improves the repeatability of temperature characteristics. Approximately 5 µm thick fiber-type thermistors exhibit an increase in the resistance by three orders of magnitude within ≈2 °C and repeatable temperature characteristics for up to 400 cycles. The mesh structure enables the thermistor layer to be ultra-lightweight and transparent; the mesh-type thermistor operates with a fiber density of 16.5 µg cm-2 , whose fiber layer has a transmittance of more than 90% in the 400-800 nm region. By fabricating the mesh thermistor on a 1.4 µm thick substrate, the thermistor operates without degradation when wrapped around a 280 µm radius needle. Furthermore, the gas-permeable property is demonstrated by fabricating the fibrous thermistor on a mesh substrate. The proposed ultrathin mesh polymer PTC thermistors form the basis for on-skin and implantable devices that are equipped with overheat prevention.


Assuntos
Polímeros , Telas Cirúrgicas , Temperatura , Polímeros/química , Acrilatos , Carbono
16.
Proc Natl Acad Sci U S A ; 119(24): e2200830119, 2022 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-35679344

RESUMO

The functional support and advancement of our body while preserving inherent naturalness is one of the ultimate goals of bioengineering. Skin protection against infectious pathogens is an application that requires common and long-term wear without discomfort or distortion of the skin functions. However, no antimicrobial method has been introduced to prevent cross-infection while preserving intrinsic skin conditions. Here, we propose an antimicrobial skin protection platform copper nanomesh, which prevents cross-infectionmorphology, temperature change rate, and skin humidity. Copper nanomesh exhibited an inactivation rate of 99.99% for Escherichia coli bacteria and influenza virus A within 1 and 10 min, respectively. The thin and porous nanomesh allows for conformal coating on the fingertips, without significant interference with the rate of skin temperature change and humidity. Efficient cross-infection prevention and thermal transfer of copper nanomesh were demonstrated using direct on-hand experiments.


Assuntos
Anti-Infecciosos , Cobre , Infecção Hospitalar , Nanopartículas Metálicas , Pele , Anti-Infecciosos/farmacologia , Cobre/farmacologia , Infecção Hospitalar/prevenção & controle , Escherichia coli/efeitos dos fármacos , Dedos , Humanos , Vírus da Influenza A/efeitos dos fármacos , Porosidade , Pele/microbiologia
17.
Sci Adv ; 8(20): eabo1396, 2022 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-35594357

RESUMO

Long-term high-fidelity electroencephalogram (EEG) recordings are critical for clinical and brain science applications. Conductive liquid-like or solid-like wet interface materials have been conventionally used as reliable interfaces for EEG recording. However, because of their simplex liquid or solid phase, electrodes with them as interfaces confront inadequate dynamic adaptability to hairy scalp, which makes it challenging to maintain stable and efficient contact of electrodes with scalp for long-term EEG recording. Here, we develop an on-skin paintable conductive biogel that shows temperature-controlled reversible fluid-gel transition to address the abovementioned limitation. This phase transition endows the biogel with unique on-skin paintability and in situ gelatinization, establishing conformal contact and dynamic compliance of electrodes with hairy scalp. The biogel is demonstrated as an efficient interface for long-term high-quality EEG recording over several days and for the high-performance capture and classification of evoked potentials. The paintable biogel offers a biocompatible and long-term reliable interface for EEG-based systems.

18.
Chem Soc Rev ; 51(9): 3759-3793, 2022 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-35420617

RESUMO

Skin bioelectronics are considered as an ideal platform for personalised healthcare because of their unique characteristics, such as thinness, light weight, good biocompatibility, excellent mechanical robustness, and great skin conformability. Recent advances in skin-interfaced bioelectronics have promoted various applications in healthcare and precision medicine. Particularly, skin bioelectronics for long-term, continuous health monitoring offer powerful analysis of a broad spectrum of health statuses, providing a route to early disease diagnosis and treatment. In this review, we discuss (1) representative healthcare sensing devices, (2) material and structure selection, device properties, and wireless technologies of skin bioelectronics towards long-term, continuous health monitoring, (3) healthcare applications: acquisition and analysis of electrophysiological, biophysical, and biochemical signals, and comprehensive monitoring, and (4) rational guidelines for the design of future skin bioelectronics for long-term, continuous health monitoring. Long-term, continuous health monitoring of advanced skin bioelectronics will open unprecedented opportunities for timely disease prevention, screening, diagnosis, and treatment, demonstrating great promise to revolutionise traditional medical practices.


Assuntos
Dispositivos Eletrônicos Vestíveis
19.
Biomed Opt Express ; 13(2): 838-849, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35284154

RESUMO

Technological advances in the real-time visualization of cutaneous microcirculation aim to realize benefits including high-resolution imaging, suppressed noise, and robust temporal coherence. Photoplethysmography (PPG), a noninvasive technique that measures single or multiple points of relative blood volume changes in blood vessels under the skin, shows potential as a signal candidate for visualizing blood vessels and tracking blood flow. However, challenges still remain, such as extracting/image reconstruction of the blood vessel/flow signal in a precise frequency window (<0.2 Hz) from a noisy image that is caused by the loss of spatial coherence of the light source in a turbid biological tissue. We attempted to overcome this challenge by adopting a combination of direct-contact-type, lens-less, conformable imagers and singular value decomposition (SVD) in this study. We focused on the numerical analysis of SVD for discriminating the tissue and vein blood flow in PPG for reconstructing blood fluidic images, followed by a complete demonstration of skin microcirculation blood tracking in the vessel visualization process when applying our lens-less, conformable, wearable imagers.

20.
Artigo em Inglês | MEDLINE | ID: mdl-35280508

RESUMO

The global consumption of plant-based cosmetics has shown spectacular growth in recent years because of rising consumer awareness regarding the long-term health benefits of natural ingredients. As the global demand for herbal cosmetics increases, there are ample opportunities for Sri Lanka as a tropical Asian country to expand its productions and global exports along with its unique biodiversity and inherited traditional knowledge. Therefore, the present review attempts to give an overview of the widely used medicinal plants in the global herbal cosmetic industry and strengths, challenges, and possible solutions for the development of the herbal cosmetic industry of Sri Lanka. Information was collected using electronic search (using Pub Med, Science Direct, Web of Science, Google Scholar, TEEAL, and Scopus) for articles published in peer-reviewed journals, industrial reports, market surveys, and library search for local books on ethnobotany. Important plant-derived ingredients used in the global herbal cosmetic industry are essential oils, colorants, oils, fats, and waxes. The traditional usage of 108 medicinal plant species (belonging to 58 families) in cosmetic treatments was identified from the local books of Sri Lanka. Of these, 49 plant species were reported as new ingredients for the herbal cosmetic industry. However, the lack of ethnobotanical and ethnopharmacological surveys to identify the cosmetic potential plants, insufficient or absence of continuous supply of raw materials for production in line with the existing demand, the lack of quality control of raw materials and finished cosmetic products, improper systematic cultivation systems for medicinal plants, poor postharvest practices, and the lack of innovations are major challenges encountered in Sri Lanka for the development of the herbal cosmetic industry. In conclusion, addressing these vital knowledge gaps is a timely requirement of the country for the sustainable development of the herbal cosmetic industry in Sri Lanka. Furthermore, assembling of the multidisciplinary cooperation of botanists, chemists, toxicologists, researchers, and biologists is crucial to analyze the interesting functional properties, efficacy, and effectiveness of documented medicinal plants with cosmetic potential.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA