Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
IEEE Trans Terahertz Sci Technol ; 12(2): 151-164, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36185397

RESUMO

A system concept for online alignment verification of millimeter-wave, corneal reflectometry is presented. The system utilizes beam scanning to generate magnitude-only reflectivity maps of the cornea at 650 GHz and compares these images to a precomputed/measured template map to confirm/reject sufficient alignment. A system utilizing 5 off-axis parabolic mirrors, a thin film beam splitter, and 2-axis galvanometric mirror was designed, simulated, and evaluated with geometric and physical optics. Simulation results informed the construction of a demonstrator system which was tested with a reference reflector. Similarity metrics computed with the aligned template and 26 misaligned positions, distributed on a 0.5 mm x 0.5 mm x 0.5 mm mesh, demonstrated sufficient misalignment detection sensitivity in 23 out of 26 positions. The results show that positional accuracy on the order of 0.5 mm is possible using 0.462 mm wavelength radiation due to the perturbation of coupling efficiency via beam distortion and beam walk-off.

2.
Netw Neurosci ; 4(3): 925-945, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33615097

RESUMO

Countless studies have advanced our understanding of the human brain and its organization by using functional magnetic resonance imaging (fMRI) to derive network representations of human brain function. However, we do not know to what extent these "functional connectomes" are reliable over time. In a large public sample of healthy participants (N = 833) scanned on two consecutive days, we assessed the test-retest reliability of fMRI functional connectivity and the consequences on reliability of three common sources of variation in analysis workflows: atlas choice, global signal regression, and thresholding. By adopting the intraclass correlation coefficient as a metric, we demonstrate that only a small portion of the functional connectome is characterized by good (6-8%) to excellent (0.08-0.14%) reliability. Connectivity between prefrontal, parietal, and temporal areas is especially reliable, but also average connectivity within known networks has good reliability. In general, while unreliable edges are weak, reliable edges are not necessarily strong. Methodologically, reliability of edges varies between atlases, global signal regression decreases reliability for networks and most edges (but increases it for some), and thresholding based on connection strength reduces reliability. Focusing on the reliable portion of the connectome could help quantify brain trait-like features and investigate individual differences using functional neuroimaging.

3.
Lasers Surg Med ; 51(4): 339-344, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30152534

RESUMO

Background and Objectives Laser generated shockwave (LGS) is a novel modality for minimally invasive disruption of bacterial biofilms. The objectives of this study are to determine the mechanisms behind LGS treatment and non-biofilm effects on bacterial disruption, including (1) comparing bacterial load with and without LGS in its planktonic form and (2) estimating bacterial cell permeability following LGS. Study Design/Materials and Methods For the first study, planktonic S. epidermidis were treated with gentamicin (0, 8, 16, 32, 64 µg/ml) with and without LGS (1064 nm Nd:YAG laser, 110.14 mJ/mm2 , pulse duration 9 ns, spot size 3 mm, n = 8/group), and absorbances at 600 nm compared. For the second study, four samples of planktonic S. epidermidis were treated with LGS (same settings). Propidium iodide (PI) uptake via flow cytometry as a measure of cell permeability was measured at 0, 10, and 20 minutes following LGS. RESULTS: In comparing corresponding gentamicin concentrations within both LGS-treated samples and controls at 0 hours, there were no differences in absorbance (P = 0.923 and P = 0.814, respectively). Flow cytometry found modest PI uptake (10.4 ± 2.5%) immediately following LGS treatment, with time-dependent increase and persistence of the signal at 20 minutes (R2 = 0.449, P = 0.048). CONCLUSION: Taken together, LGS does not appear to have direct bacteriocidal properties, but rather by allowing for biofilm disruption and bacterial cell membrane permeabilization, both of which likely increase topical antibiotic delivery to pathogenic organisms. Insight into the mechanisms of LGS will allow for improved clinical applications and facilitate safe and effective translation of this technology. Lasers Surg. Med. © 2018 Wiley Periodicals, Inc.


Assuntos
Carga Bacteriana/efeitos da radiação , Biofilmes/efeitos da radiação , Membrana Celular/efeitos da radiação , Lasers de Estado Sólido , Staphylococcus epidermidis/efeitos da radiação , Antibacterianos/farmacologia , Carga Bacteriana/efeitos dos fármacos , Biofilmes/efeitos dos fármacos , Membrana Celular/efeitos dos fármacos , Citometria de Fluxo , Gentamicinas/farmacologia , Permeabilidade/efeitos dos fármacos , Permeabilidade/efeitos da radiação , Plâncton/efeitos dos fármacos , Plâncton/efeitos da radiação , Staphylococcus epidermidis/efeitos dos fármacos
4.
Otolaryngol Head Neck Surg ; 159(5): 824-829, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30040545

RESUMO

OBJECTIVE: A cerebrospinal fluid leak is one of the most serious complications in otolaryngology. It may occur as a result of injury to the skull base, typically traumatic or iatrogenic. While the presence of a leak is often discerned in the emergent setting, distinguishing normal secretions from those containing cerebrospinal fluid can be difficult during postoperative visits in the clinic. As most current laboratory-based assays are labor intensive and require several days to result, we aim to develop a more user-friendly and rapid point-of-care cerebrospinal fluid detection device. STUDY DESIGN: Our laboratory developed a barcode-style lateral-flow immunoassay utilizing antibodies for beta-trace protein, a protein abundant in and specific for cerebrospinal fluid, with a concentration of 1.3 mg/L delineating a positive result. SETTING: Tertiary medical center. SUBJECTS AND METHODS: Tests with known concentrations of resuspended beta-trace protein and the contents of discarded lumbar drains (presumed to contain cerebrospinal fluid) were performed to validate our novel device. RESULTS: Our results demonstrate the ability of our device to semiquantitatively identify concentrations of beta-trace protein from 0.3-90 mg/L, which is within the required range to diagnose a leak, thus making beta-trace protein an excellent target for rapid clinical detection. CONCLUSION: Herein we detail the creation and initial validation of the first point-of-care cerebrospinal fluid detection device. This device is a feasible method to more efficiently and cost-effectively identify cerebrospinal fluid leaks, minimize costs, and improve patient outcomes.


Assuntos
Vazamento de Líquido Cefalorraquidiano/diagnóstico , Oxirredutases Intramoleculares/análise , Lipocalinas/análise , Sistemas Automatizados de Assistência Junto ao Leito , Reações Falso-Positivas , Feminino , Humanos , Imunoensaio , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Centros de Atenção Terciária
5.
IEEE Trans Terahertz Sci Technol ; 8(1): 27-37, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29430335

RESUMO

Terahertz (THz) imaging of corneal tissue water content (CTWC) is a proposed method for early, accurate detection and study of corneal diseases. Despite promising results from ex vivo and in vivo cornea studies, interpretation of the reflectivity data is confounded by the contact between corneal tissue and rigid dielectric window used to flatten the imaging field. This work develops a novel imaging system and image reconstruction methods specifically for nearly spherical targets such as human cornea. A prototype system was constructed using a 650 GHz multiplier source and Schottky diode detector. Resolution and imaging field strength measurement from characterization targets correlate well with those predicted by the quasioptical theory and physical optics analysis. Imaging experiments with corneal phantoms and ex vivo corneas demonstrate the hydration sensitivity of the imaging system and reliable measurement of CTWC. We present successful acquisition of non-contact THz images of in vivo human cornea, and discuss strategies for optimizing the imaging system design for clinical use.

6.
IEEE Trans Terahertz Sci Technol ; 8(1): 1-12, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29450106

RESUMO

Reflection mode Terahertz (THz) imaging of corneal tissue water content (CTWC) is a proposed method for early, accurate detection and study of corneal diseases. Despite promising results from ex vivo and in vivo cornea studies, interpretation of the reflectivity data is confounded by the contact between corneal tissue and dielectric windows used to flatten the imaging field. Herein, we present an optical design for non-contact THz imaging of cornea. A beam scanning methodology performs angular, normal incidence sweeps of a focused beam over the corneal surface while keeping the source, detector, and patient stationary. A quasioptical analysis method is developed to analyze the theoretical resolution and imaging field intensity profile. These results are compared to the electric field distribution computed with a physical optics analysis code. Imaging experiments validate the optical theories behind the design and suggest that quasioptical methods are sufficient for designing of THz corneal imaging systems. Successful imaging operations support the feasibility of non-contact in vivo imaging. We believe that this optical system design will enable the first, clinically relevant, in vivo exploration of CTWC using THz technology.

7.
PLoS One ; 13(1): e0191919, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29373598

RESUMO

Viscoelasticity of soft tissue is often related to pathology, and therefore, has become an important diagnostic indicator in the clinical assessment of suspect tissue. Surgeons, particularly within head and neck subsites, typically use palpation techniques for intra-operative tumor detection. This detection method, however, is highly subjective and often fails to detect small or deep abnormalities. Vibroacoustography (VA) and similar methods have previously been used to distinguish tissue with high-contrast, but a firm understanding of the main contrast mechanism has yet to be verified. The contributions of tissue mechanical properties in VA images have been difficult to verify given the limited literature on viscoelastic properties of various normal and diseased tissue. This paper aims to investigate viscoelasticity theory and present a detailed description of viscoelastic experimental results obtained in tissue-mimicking phantoms (TMPs) and ex vivo tissues to verify the main contrast mechanism in VA and similar imaging modalities. A spherical-tip micro-indentation technique was employed with the Hertzian model to acquire absolute, quantitative, point measurements of the elastic modulus (E), long term shear modulus (η), and time constant (τ) in homogeneous TMPs and ex vivo tissue in rat liver and porcine liver and gallbladder. Viscoelastic differences observed between porcine liver and gallbladder tissue suggest that imaging modalities which utilize the mechanical properties of tissue as a primary contrast mechanism can potentially be used to quantitatively differentiate between proximate organs in a clinical setting. These results may facilitate more accurate tissue modeling and add information not currently available to the field of systems characterization and biomedical research.


Assuntos
Elasticidade , Modelos Animais , Imagens de Fantasmas , Viscosidade , Animais , Masculino , Ratos Sprague-Dawley , Suínos
8.
Lasers Surg Med ; 49(5): 539-547, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28333393

RESUMO

BACKGROUND AND OBJECTIVES: Bacterial biofilm formation within chronic wound beds, which provides an effective barrier against antibiotics, is a known cause of recalcitrant infections and a significant healthcare burden, often requiring repeated surgical debridements. Laser-generated shockwaves (LGS) is a novel, minimally invasive, and nonthermal modality for biofilm mechanical debridement which utilizes compressive stress waves, generated by photonic absorption in thin titanium films to mechanically disrupt the biofilm. Prior studies have demonstrated LGS monotherapy to be selectively efficacious for biofilm disruption and safe for host tissues. In this study, we sought to determine if LGS can enhance the antimicrobial activity and biofilm disruption capability of topical antibiotic therapy. STUDY DESIGN/MATERIALS AND METHODS: Staphylococcus epidermidis biofilms grown in vitro on glass were treated with topical gentamicin (31, 62, and 124 µg/ml) with and without LGS (n = 3-11/treatment group). Mechanical shockwaves were generated with a 1,064 nm Nd:YAG laser (laser fluence 110.14 mJ/mm2 , pulse duration 5 ns, spot size 3 mm). Following a 24-hour incubation period, bacterial viability was assessed by determining the number of colony-forming units (CFU) via the Miles and Misra method. Residual biofilm bioburden was analyzed using the crystal violet biofilm assay. RESULTS: With gentamicin monotherapy, CFU density (CFU/mm2 ) at 31, 62, and 124 µg/ml were (282 ± 84) × 104 , (185 ± 34) × 104 , and (113 ± 9) × 104 , respectively. With LGS and gentamicin therapy, CFU density decreased to (170 ± 44) × 104 , (89 ± 24) × 104 , and (43 ± 3) × 104 , respectively (P = 0.1704, 0.0302, and 0.0004 when compared with gentamicin alone). Biofilm burden as measured by the assay in the gentamicin 31, 62, and 124 µg/ml groups was reduced by 80%, 95%, and 98% when LGS was added (P = 0.0102, >0.0001, and 0.0001 for all groups when compared with gentamicin alone). Furthermore, samples treated with LGS saw an increase in susceptibility to gentamicin, in terms of reduced biofilm bioburden and CFU densities. CONCLUSION: LGS enhances the efficacy of topical antibiotics in an in vitro model. This has significant implications for clinical applications in the management of chronic soft tissue infections and recalcitrant chronic rhinosinusitis. Lasers Surg. Med. 49:539-547, 2017. © 2017 Wiley Periodicals, Inc.


Assuntos
Antibacterianos/uso terapêutico , Biofilmes/efeitos da radiação , Gentamicinas/uso terapêutico , Ondas de Choque de Alta Energia , Lasers de Estado Sólido/uso terapêutico , Staphylococcus epidermidis/efeitos da radiação , Carga Bacteriana/efeitos dos fármacos , Carga Bacteriana/efeitos da radiação , Biofilmes/crescimento & desenvolvimento , Staphylococcus epidermidis/efeitos dos fármacos , Staphylococcus epidermidis/fisiologia
9.
IEEE Trans Biomed Eng ; 64(11): 2682-2694, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28141514

RESUMO

OBJECTIVE: In vivo visualization and quantification of edema, or 'tissue swelling' following injury, remains a clinical challenge. Herein, we investigate the ability of reflective terahertz (THz) imaging to track changes in tissue water content (TWC)-the direct indicator of edema-by comparison to depth-resolved magnetic resonance imaging (MRI) in a burn-induced model of edema. METHODS: A partial thickness and full thickness burns were induced in an in vivo rat model to elicit unique TWC perturbations corresponding to burn severity. Concomitant THz surface maps and MRI images of both burn models were acquired with a previously reported THz imaging system and T2-weighted MRI, respectively, over 270 min. Reflectivity was analyzed for the burn contact area in THz images, while proton density (i.e., mobile TWC) was analyzed for the same region at incrementally increasing tissue depths in companion, transverse MRI images. A normalized cross correlation of THz and depth-dependent MRI measurements was performed as a function of time in histologically verified burn wounds. RESULTS: For both burn types, strong positive correlations were evident between THz reflectivity and MRI data analyzed at greater tissue depths (>258 µm). MRI and THz results also revealed biphasic trends consistent with burn edema pathogenesis. CONCLUSION: This paper offers the first in vivo correlative assessment of mobile TWC-based contrast and the sensing depth of THz imaging. SIGNIFICANCE: The ability to implement THz imaging immediately following injury, combined with TWC sensing capabilities that compare to MRI, further support THz sensing as an emerging tool to track fluid in tissue.


Assuntos
Queimaduras/diagnóstico por imagem , Edema/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagem Terahertz/métodos , Animais , Modelos Animais de Doenças , Interpretação de Imagem Assistida por Computador , Masculino , Ratos , Ratos Sprague-Dawley , Processamento de Sinais Assistido por Computador
10.
Otolaryngol Head Neck Surg ; 156(3): 480-483, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28116982

RESUMO

The variable location and indistinct features of parathyroid glands can make their intraoperative identification challenging. Currently, there exists no routine use of localization methods during surgery. Dynamic optical contrast imaging (DOCI) leverages a novel realization of temporally dependent measurements of tissue autofluorescence that allows the acquisition of specific tissue properties. A prospective series of patients with primary hyperparathyroidism was examined. Parathyroid lesions and surrounding tissues were collected; fluorescence decay images were acquired via DOCI. Ex vivo samples (81 patients) were processed for histologic assessment. DOCI extracts relative fluorescence decay information in a surgically relevant field of view with a clinically accessible acquisition time <2 minutes. Analysis of DOCI revealed microscopic characterization sufficient for tissue type identification consistent with histology ( P < .05). DOCI is capable of efficiently distinguishing parathyroid tissue from adjacent tissues. Such an intraoperative tool would be transformative, helping surgeons to identify lesions, preserve healthy tissue, and improve patient outcomes.


Assuntos
Imagem Óptica , Glândulas Paratireoides/anatomia & histologia , Glândulas Paratireoides/diagnóstico por imagem , Humanos , Hiperparatireoidismo Primário/diagnóstico por imagem , Hiperparatireoidismo Primário/cirurgia
11.
Biomed Opt Express ; 8(1): 460-474, 2017 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-28101431

RESUMO

Accurate and early prediction of tissue viability is the most significant determinant of tissue flap survival in reconstructive surgery. Perturbation in tissue water content (TWC) is a generic component of the tissue response to such surgeries, and, therefore, may be an important diagnostic target for assessing the extent of flap viability in vivo. We have previously shown that reflective terahertz (THz) imaging, a non-ionizing technique, can generate spatially resolved maps of TWC in superficial soft tissues, such as cornea and wounds, on the order of minutes. Herein, we report the first in vivo pilot study to investigate the utility of reflective THz TWC imaging for early assessment of skin flap viability. We obtained longitudinal visible and reflective THz imagery comparing 3 bipedicled flaps (i.e. survival model) and 3 fully excised flaps (i.e. failure model) in the dorsal skin of rats over a postoperative period of 7 days. While visual differences between both models manifested 48 hr after surgery, statistically significant (p < 0.05, independent t-test) local differences in TWC contrast were evident in THz flap image sets as early as 24 hr. Excised flaps, histologically confirmed as necrotic, demonstrated a significant, yet localized, reduction in TWC in the flap region compared to non-traumatized skin. In contrast, bipedicled flaps, histologically verified as viable, displayed mostly uniform, unperturbed TWC across the flap tissue. These results indicate the practical potential of THz TWC sensing to accurately predict flap failure 24 hours earlier than clinical examination.

12.
Cancer ; 123(5): 879-886, 2017 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-27763689

RESUMO

BACKGROUND: Head and neck squamous cell carcinomas (HNSCCs) are debilitating diseases for which a patient's prognosis depends heavily on complete tumor resection. Currently, the surgeon's fingers determine the location of tissue margins. This study evaluated the diagnostic utility of a novel imaging modality, dynamic optical contrast imaging (DOCI), in the detection of HNSCC. This system generates contrast by illuminating the tissue with pulsed light and detecting variations in endogenous fluorophore lifetimes. METHODS: A total of 47 fresh ex vivo samples from 15 patients were imaged with the DOCI system immediately after surgical resection. DOCI maps were analyzed to determine the statistical significance of contrast between tumors and adjacent nonmalignant tissue. Pilot intraoperative clinical data were also acquired. RESULTS: Statistical significance (P < .05) between muscle and tumor was established for 10 of 10 emission wavelengths, between collagen and tumor for 8 of 10 emission wavelengths, and between fat and tumor for 2 of 10 wavelengths. The system extracted relative fluorescence decay information in a surgically relevant field of view in <2 minutes. CONCLUSIONS: This study demonstrates the feasibility of using DOCI to rapidly and accurately distinguish HNSCC from surrounding normal tissue. An analysis of DOCI images revealed microscopic characterization sufficient for tissue-type identification consistent with histology. Such an intraoperative tool would be transformative by allowing the rapid delineation of tumor tissue from nontumor tissue and thus maximizing the efficacy of resection and improving patient outcomes. Cancer 2017;123:879-86. © 2016 American Cancer Society.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Diagnóstico por Imagem/métodos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Imagem Óptica/métodos , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/cirurgia , Neoplasias de Cabeça e Pescoço/patologia , Neoplasias de Cabeça e Pescoço/cirurgia , Humanos , Carcinoma de Células Escamosas de Cabeça e Pescoço
13.
Proc SPIE Int Soc Opt Eng ; 93622015 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-26321784

RESUMO

This paper presents a novel THz optical design that allows the acquisition of THz reflectivity maps of in vivo cornea without the need for a field flattening window and preliminary imaging results of in vivo rabbit cornea. The system's intended use is to sense small changes in corneal tissue water content (CTWC) that can be precursors for a host of diseases and pathologies. Unique beam optics allows the scanning of a curved surface at normal incidence while keeping the source detector and target stationary. Basic system design principles are discussed and image sets of spherical calibration targets and corneal phantom models are presented. The presented design will enable, for the first time, non-contact THz imaging of animal and human cornea.

14.
IEEE Trans Terahertz Sci Technol ; 5(2): 170-183, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26322247

RESUMO

Terahertz (THz) spectral properties of human cornea are explored as a function of central corneal thickness (CCT) and corneal water content, and the clinical utility of THz-based corneal water content sensing is discussed. Three candidate corneal tissue water content (CTWC) perturbations, based on corneal physiology, are investigated that affect the axial water distribution and total thickness. The THz frequency reflectivity properties of the three CTWC perturbations were simulated and explored with varying system center frequency and bandwidths (Q-factors). The modeling showed that at effective optical path lengths on the order of a wavelength the cornea presents a lossy etalon bordered by air at the anterior and the aqueous humor at the posterior. The simulated standing wave peak-to-valley ratio is pronounced at lower frequencies and its effect on acquired data can be modulated by adjusting the bandwidth of the sensing system. These observations are supported with experimental spectroscopic data. The results suggest that a priori knowledge of corneal thickness can be utilized for accurate assessments of corneal tissue water content. The physiologic variation of corneal thickness with respect to the wavelengths spanned by the THz band is extremely limited compared to all other structures in the body making CTWC sensing unique amongst all proposed applications of THz medical imaging.

15.
IEEE Trans Terahertz Sci Technol ; 5(2): 184-196, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26161292

RESUMO

A pulsed terahertz (THz) imaging system and millimeter-wave reflectometer were used to acquire images and point measurements, respectively, of five rabbit cornea in vivo. These imaging results are the first ever produced of in vivo cornea. A modified version of a standard protocol using a gentle stream of air and a Mylar window was employed to slightly dehydrate healthy cornea. The sensor data and companion central corneal thickness (CCT) measurements were acquired every 10-15 min over the course of two hours using ultrasound pachymmetry.. Statistically significant positive correlations were established between CCT measurements and millimeter wave reflectivity. Local shifts in reflectivity contrast were observed in the THz imagery; however, the THz reflectivity did not display a significant correlation with thickness in the region probed by the 100 GHz and CCT measurements. This is explained in part by a thickness sensitivity at least 10× higher in the mm-wave than the THz systems. Stratified media and effective media modeling suggest that the protocol perturbed the thickness and not the corneal tissue water content (CTWC). To further explore possible etalon effects, an additional rabbit was euthanized and millimeter wave measurements were obtained during death induced edema. These observations represent the first time that the uncoupled sensing of CTWC and CCT have been achieved in vivo.

16.
Stud Health Technol Inform ; 196: 262-4, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24732519

RESUMO

In the absence of an imaging technique that provides imagery of diseased tissue with high diagnostic accuracy and contrast, surgeons must often excise excess healthy tissue surrounding neoplasms to ensure complete removal of malignant tissues. Additional approaches that are commonly used in the detection of tumor regions include palpation and conventional ultrasound to locate the affected area. However, these techniques suffer from limitations such as minimal specificity and lack of depth penetration. Lack of specificity results in the production of unclear diseased tissue regions, and therefore fails to offer surgeons a reliable and accurate image guidance tool. The proposed work provides an alternative diagnostic modality termed ultrasound-stimulated vibro-acoustography (USVA) that aims to generate detailed images characterized by viscoelastic properties of tissues. We demonstrate selective imaging using phantom tissue samples of polyvinyl alcohol (PVA) that are altered and arranged into unique geometries of varying elastic topology. Determining the precision and sensitivity of the USVA imaging system in identifying boundary regions as well as intensity ranges associated with tissue phantom targets will provide additional important information to allow for a non-invasive tool to distinguish diseased tissues from normal tissues in an in vivo setting.


Assuntos
Módulo de Elasticidade/fisiologia , Técnicas de Imagem por Elasticidade/instrumentação , Aumento da Imagem/instrumentação , Transdutores , Viscosidade , Diagnóstico Diferencial , Técnicas de Imagem por Elasticidade/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
J Biomed Opt ; 17(4): 040503, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22559669

RESUMO

A reflective, pulsed terahertz (THz) imaging system was used to acquire high-resolution (d(10-90)/λ~1.925) images of deep, partial thickness burns in a live rat. The rat's abdomen was burned with a brass brand heated to ~220°C and pressed against the skin with contact pressure for ~10 sec. The burn injury was imaged beneath a Mylar window every 15 to 30 min for up to 7 h. Initial images display an increase in local water concentration of the burned skin as evidenced by a marked increase in THz reflectivity, and this likely correlates to the post-injury inflammatory response. After ~1 h the area of increased reflectivity consolidated to the region of skin that had direct contact with the brand. Additionally, a low reflecting ring of tissue could be observed surrounding the highly reflective burned tissue. We hypothesize that these regions of increased and decreased reflectivity correlate to the zones of coagulation and stasis that are the classic foundation of burn wound histopathology. While further investigations are necessary to confirm this hypothesis, if true, it likely represents the first in vivo THz images of these pathologic zones and may represent a significant step forward in clinical application of THz technology.


Assuntos
Queimaduras/patologia , Processamento de Sinais Assistido por Computador , Imagem Terahertz/métodos , Animais , Técnicas Histológicas , Masculino , Ratos , Ratos Sprague-Dawley
18.
J Biomed Opt ; 16(5): 057003, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21639581

RESUMO

This work introduces the potential application of terahertz (THz) sensing to the field of ophthalmology, where it is uniquely suited due to its nonionizing photon energy and high sensitivity to water content. Reflective THz imaging and spectrometry data are reported on ex-vivo porcine corneas prepared with uniform water concentrations using polyethylene glycol (PEG) solutions. At 79% water concentration by mass, the measured reflectivity of the cornea was 20.4%, 14.7%, 11.7%, 9.6%, and 7.4% at 0.2, 0.4, 0.6, 0.8, and 1 THz, respectively. Comparison of nine corneas hydrated from 79.1% to 91.5% concentration by mass demonstrated an approximately linear relationship between THz reflectivity and water concentration, with a monotonically decreasing slope as the frequency increases. The THz-corneal tissue interaction is simulated with a Bruggeman model with excellent agreement. THz applications to corneal dystrophy, graft rejection, and refractive surgery are examined from the context of these measurements.


Assuntos
Água Corporal/química , Córnea/química , Técnicas de Diagnóstico Oftalmológico/instrumentação , Espectroscopia Terahertz/instrumentação , Água/análise , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Técnicas In Vitro , Suínos
19.
Stud Health Technol Inform ; 163: 394-6, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21335826

RESUMO

Bacterial biofilm-related infections are a burden on the healthcare industry. The effect of laser generated shockwaves through polycarbonate, a flexible polymer, is explored for its ability to generate high peak stresses, and also for its ability to conform to complex wound surfaces. Shockwave pulses in Al coated polycarbonate substrates and a resulting peak stress of greater than 60 MPa was measured which should provide sufficient pressure to kill bacteria.


Assuntos
Fenômenos Fisiológicos Bacterianos/efeitos da radiação , Biofilmes/crescimento & desenvolvimento , Biofilmes/efeitos da radiação , Desinfecção/métodos , Lasers , Membranas Artificiais , Polímeros/efeitos da radiação
20.
Stud Health Technol Inform ; 163: 653-7, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21335874

RESUMO

A reflective THz imaging system sensitive to small variations in water concentrations has been developed. Biological tissues such as skin, eyes and teeth were imaged to ascertain the systems response to tissue hydration. Difference in water concentrations translated to contrast in the THz images. Contrast was also seen in THz images of skin cancer and burns suggesting the potential diagnostic capability of THz imaging system in clinical settings. All specimens analyzed were freshly excised ex-vivo tissues. These encouraging preliminary results have motivated us to explore the in vivo potential of our imaging system.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imagem Terahertz/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA