Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Phys Med Biol ; 68(14)2023 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-37267994

RESUMO

Objective.Quality assurance (QA) testing must be performed at regular intervals to ensure that medical devices are operating within designed specifications. Numerous QA phantoms and software packages have been developed to facilitate measurements of machine performance. However, due to the hard-coded nature of geometric phantom definition in analysis software, users are typically limited to the use of a small subset of compatible QA phantoms. In this work, we present a novel AI-based universal Phantom (UniPhan) algorithm that is not phantom specific and can be easily adapted to any pre-existing image-based QA phantom.Approach.Extensible Markup Language Scalable Vector Graphics (XML-SVG) was modified to include several new tags describing the function of embedded phantom objects for use in QA analysis. Functional tags include contrast and density plugs, spatial linearity markers, resolution bars and edges, uniformity regions, and light-radiation field coincidence areas. Machine learning was used to develop an image classification model for automatic phantom type detection. After AI phantom identification, UniPhan imported the corresponding XML-SVG wireframe, registered it to the image taken during the QA process, performed analysis on the functional tags, and exported results for comparison to expected device specifications. Analysis results were compared to those generated by manual image analysis.Main results.XML-SVG wireframes were generated for several commercial phantoms including ones specific to CT, CBCT, kV planar imaging, and MV imaging. Several functional objects were developed and assigned to the graphical elements of the phantoms. The AI classification model was tested for training and validation accuracy and loss, along with phantom type prediction accuracy and speed. The results reported training and validation accuracies of 99%, phantom type prediction confidence scores of around 100%, and prediction speeds of around 0.1 s. Compared to manual image analysis, Uniphan results were consistent across all metrics including contrast-to-noise ratio, modulation-transfer function, HU accuracy, and uniformity.Significance.The UniPhan method can identify phantom type and use its corresponding wireframe to perform QA analysis. As these wireframes can be generated in a variety of ways this represents an accessible automated method of analyzing image-based QA phantoms that is flexible in scope and implementation.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Processamento de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Imagens de Fantasmas , Inteligência Artificial
2.
Radiat Res ; 198(2): 181-189, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35640166

RESUMO

FLASH is a high-dose-rate form of radiation therapy that has the reported ability, compared with conventional dose rates, to spare normal tissues while being equipotent in tumor control, thereby increasing the therapeutic ratio. The mechanism underlying this normal tissue sparing effect is currently unknown, however one possibility is radiochemical oxygen depletion (ROD) during dose delivery in tissue at FLASH dose rates. In order to investigate this possibility, we used the phosphorescence quenching method to measure oxygen partial pressure before, during and after proton radiation delivery in model solutions and in normal muscle and sarcoma tumors in mice, at both conventional (Conv) (∼0.5 Gy/s) and FLASH (∼100 Gy/s) dose rates. Radiation dosimetry was determined by Advanced Markus Chamber and EBT-XL film. For solutions contained in sealed glass vials, phosphorescent probe Oxyphor PtG4 (1 µM) was dissolved in a buffer (10 mM HEPES) containing glycerol (1 M), glucose (5 mM) and glutathione (5 mM), designed to mimic the reducing and free radical-scavenging nature of the intracellular environment. In vivo oxygen measurements were performed 24 h after injection of PtG4 into the interstitial space of either normal thigh muscle or subcutaneous sarcoma tumors in mice. The "g-value" for ROD is reported in mmHg/Gy, which represents a slight modification of the more standard chemical definition (µM/Gy). In solutions, proton irradiation at conventional dose rates resulted in a g-value for ROD of up to 0.55 mmHg/Gy, consistent with earlier studies using X or gamma rays. At FLASH dose rates, the g-value for ROD was ∼25% lower, 0.37 mmHg/Gy. pO2 levels were stable after each dose delivery. For normal muscle in vivo, oxygen depletion during irradiation was counterbalanced by resupply from the vasculature. This process was fast enough to maintain tissue pO2 virtually unchanged at Conv dose rates. However, during FLASH irradiation there was a stepwise decrease in pO2 (g-value ∼0.28 mmHg/Gy), followed by a rebound to the initial level after ∼8 s. The g-values were smaller and recovery times longer in tumor tissue when compared to muscle and may be related to the lower initial endogenous pO2 levels in the former. Considering that the FLASH effect is seen in vivo even at doses as low as 10 Gy, it is difficult to reconcile the amount of protection seen by oxygen depletion alone. However, the phosphorescence probe in our experiments was confined to the extracellular space, and it remains possible that intracellular oxygen depletion was greater than observed herein. In cell-mimicking solutions the oxygen depletion g-vales were indeed significantly higher than observed in vivo.


Assuntos
Prótons , Sarcoma , Animais , Raios gama , Camundongos , Oxigênio , Radiometria/métodos , Dosagem Radioterapêutica , Sarcoma/radioterapia
3.
Med Phys ; 49(8): 5400-5408, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35608256

RESUMO

PURPOSE: There is growing interest in the use of modern 3D printing technology to implement intensity-modulated radiation therapy (IMRT) on the preclinical scale that is analogous to clinical IMRT. However, current 3D-printed IMRT methods suffer from complex modulation patterns leading to long delivery times, excess filament usage, and less accurate compensator fabrication. In this work, we have developed a total variation regularization (TVR) approach to address these issues. METHODS: TVR-IMRT was used to optimize the beamlet intensity map, which was then converted to a thickness of the corresponding compensator attenuation region in copper-doped polylactic acid (PLA) filament. IMRT and TVR-IMRT heart and lung plans were generated for two different mice using three, five, or seven gantry angles. The total compensator thickness, total variation of compensator beamlet thicknesses, total variation of beamlet intensities, and exposure time were compared. The individual field doses and composite dose were delivered to film for one plan and gamma analysis was performed. RESULTS: In total, 12 mice heart and lung plans were generated for both IMRT and TVR-IMRT cases. Across all cases, it was found that TVR-IMRT reduced the total variation of compensator beamlet thicknesses and beamlet intensities by 54 ± 4 % $54\pm 4\%$ and 50 ± 3 % $50\pm 3\%$ on average when compared to standard 3D-printed compensator IMRT. On average, the total mass of compensator material consumed and radiation beam-on time were reduced by 45 ± 6 % $45\pm 6\%$ and 24 ± 4 % $24\pm 4\%$ , respectively, whereas dose metrics remained comparable. Heart plan compensators were printed and delivered to film and subsequent gamma analysis performed for each of the single fields as well as the composite dose. For the composite delivery, a passing rate of 89.1% for IMRT and 95.4% for TVR-IMRT was achieved for a 3 % / 0.3 $3\%/0.3$ mm criterion. CONCLUSIONS: TVR can be applied to small animal IMRT beamlet intensities to produce fluence maps and subsequent 3D-printed compensator patterns with significantly less complexity while still maintaining similar dose conformity to traditional IMRT. This can simplify/accelerate the 3D printing process, reduce the amount of filament required, and reduce overall beam-on time to deliver a plan.


Assuntos
Radioterapia de Intensidade Modulada , Animais , Pulmão , Camundongos , Impressão Tridimensional , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos
4.
Int J Radiat Oncol Biol Phys ; 113(3): 624-634, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35314293

RESUMO

PURPOSE: Radiation therapy delivered at ultrafast dose rates, known as FLASH RT, has been shown to provide a therapeutic advantage compared with conventional radiation therapy by selectively protecting normal tissues. Radiochemical depletion of oxygen has been proposed to underpin the FLASH effect; however, experimental validation of this hypothesis has been lacking, in part owing to the inability to measure oxygenation at rates compatible with FLASH. METHODS AND MATERIALS: We present a new variant of the phosphorescence quenching method for tracking oxygen dynamics with rates reaching up to ∼3.3 kHz. Using soluble Oxyphor probes we were able to resolve, both in vitro and in vivo, oxygen dynamics during the time of delivery of proton FLASH. RESULTS: In vitro in solutions containing bovine serum albumin the O2 depletion g values (moles/L of O2 depleted per radiation dose, eg, µM/Gy) are higher for conventional irradiation (by ∼13% at 75 µM [O2]) than for FLASH, and in the low-oxygen region (<25 µM [O2]) they decrease with oxygen concentration. In vivo, depletion of oxygen by a single FLASH is insufficient to achieve severe hypoxia in initially well-oxygenated tissue, and the g values measured appear to correlate with baseline oxygen levels. CONCLUSIONS: The developed method should be instrumental in radiobiological studies, such as studies aimed at unraveling the mechanism of the FLASH effect. The FLASH effect could in part originate from the difference in the oxygen dependencies of the oxygen consumption g values for conventional versus FLASH RT.


Assuntos
Terapia com Prótons , Prótons , Humanos , Pulmão , Oxigênio , Terapia com Prótons/métodos , Radiobiologia , Dosagem Radioterapêutica
5.
Sci Rep ; 10(1): 14866, 2020 09 10.
Artigo em Inglês | MEDLINE | ID: mdl-32913201

RESUMO

The composition, stoichiometry and interactions of supramolecular protein complexes are a critical determinant of biological function. Several techniques have been developed to study molecular interactions and quantify subunit stoichiometry at the single molecule level. However, these typically require artificially low expression levels or detergent isolation to achieve the low fluorophore concentrations required for single molecule imaging, both of which may bias native subunit interactions. Here we present an alternative approach where protein complexes are assembled at physiological concentrations and subsequently diluted in situ for single-molecule level observations while preserving them in a near-native cellular environment. We show that coupling this dilution strategy with fluorescence correlation spectroscopy permits quantitative assessment of cytoplasmic oligomerization, while stepwise photobleaching and single molecule colocalization may be used to study the subunit stoichiometry of membrane receptors. Single protein recovery after dilution (SPReAD) is a simple and versatile means of extending the concentration range of single molecule measurements into the cellular regime while minimizing potential artifacts and perturbations of protein complex stoichiometry.


Assuntos
Corantes Fluorescentes/química , Microscopia de Fluorescência/métodos , Complexos Multiproteicos/química , Imagem Individual de Molécula/métodos , Fusão Celular , Humanos , Complexos Multiproteicos/metabolismo , Fotodegradação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA