Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Animals (Basel) ; 13(23)2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-38066951

RESUMO

In neonatal equines, pathologies involving umbilical structures are an important cause of morbidity, and surgical removal of urachal remnants is a common procedure in clinical practice. Surgery involving the ventral abdominal wall can cause substantial pain, leading to complications and prolonged recovery. The objectives of this study were to describe a two-point bilateral ultrasound-guided rectus sheath block at the level of the umbilicus and to evaluate the extent of dye distribution in foal cadavers. Ten foal cadavers were included in the study, in which a bilateral two-point ultrasound-guided rectus sheath block was performed-one injection 5 cm cranially and a second one 5 cm caudally to the umbilicus. The injectate consisted of a mixture of iodinated contrast medium and blue dye at a volume of 0.25 mL kg-1 per injection point (total 1 mL kg-1). After the injection, computer tomography and subsequent dissection of the ventral abdominal wall were performed. The extension of the contrast medium, the number of stained nerves, and contamination of the abdominal cavity were evaluated. The cranio-caudal extension of the contrast ranged from 0.8 to 1.4 cm per milliliter of injectate. The most commonly stained ventral branches of spinal nerves were thoracic (Th) nerves 16, 17, and 18 (95%, 85%, and 80% of the nerves, respectively). Abdominal contamination was found in four animals. The results suggest that the block could provide periumbilical analgesia. Further studies with different volumes of injectate and living animals are warranted.

2.
Vet Rec ; : e3604, 2023 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-37953683

RESUMO

BACKGROUND: Ensuring patient safety during small animal anaesthesia is crucial. This study aimed to assess anaesthetic-related deaths in dogs globally, identify risks and protective factors and inform clinical practice. METHODS: This prospective cohort multicentric study involved 55,022 dogs from 405 veterinary centres across various countries. Data on anaesthesia-related deaths from premedication to 48 hours post-extubation were collected. Logistic regression was used to analyse patient demographics, American Society of Anesthesiologists (ASA) classification, procedure type and anaesthetic drugs used. RESULTS: Anaesthetic-related mortality was 0.69%. Most deaths occurred postoperatively (81%). Age, obesity and a higher ASA classification score were associated with increased mortality. Urgent procedures, non-urgent but unscheduled anaesthesias and short procedures also had higher mortality. Some sedatives, systemic analgesics, hypnotics and the use of locoregional anaesthesia were linked to a decrease in mortality. LIMITATIONS: The limitations of the study include the non-randomised sample, potential selection bias, lack of response rate quantification, variable data quality control, subjectivity in classifying causes of death and limited analysis of variables. CONCLUSION: Careful patient evaluation, drug selection and monitoring can be associated with reduced mortality. These findings can be used to develop guidelines and strategies to improve patient safety and outcomes. Further research is needed to refine protocols, enhance data quality systems and explore additional risk mitigation measures.

4.
Vet Anaesth Analg ; 49(5): 433-442, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35985925

RESUMO

OBJECTIVES: To quantify and explore risk factors in dogs seen at primary care UK veterinary clinics for general anaesthetic (GA)/sedative-related death overall, in addition to neuter-specific procedures. STUDY DESIGN: A nested case-control study within UK primary care veterinary electronic patient record surveillance programme, VetCompass, including over 300 UK veterinary practices. ANIMALS: A total of 157,318 dogs undergoing GA/sedative events. METHODS: Cases included dogs undergoing GA/sedative events between January 2010 and December 2013 with GA/sedative-related death recorded within 48 hours or 2 weeks of the event. Controls were randomly selected from dogs undergoing GA/sedation that did not die within these time periods. Risks of GA/sedative-related death for all surgeries and neuter-specific surgeries were estimated. Demographic and clinical associations with GA/sedative-related death were reported as odds ratios following multivariable logistic regression modelling. Statistical significance was set at 5%. RESULTS: From 157,318 dogs with a GA/sedative event, there were 159 (0.10%) within 48 hours and 219 (0.14%) GA/sedative-related deaths within 2 weeks. Within 89,852 dogs that underwent a neuter surgery, there were eight GA/sedative related (0.009%). Greater age, poorer American Society of Anaesthesiologists health status scores and more urgent procedures were associated with greater odds of death. Compared with mixed breeds, Rottweilers and West Highland White Terriers had greater odds and Cocker Spaniels had lower odds of GA/sedative-related death. CONCLUSIONS AND CLINICAL RELEVANCE: The overall risk for GA/sedative related death was relatively low, particularly among the subset of dogs undergoing castration or ovariohysterectomy surgery. Associations and risk estimates may assist shared decision-making in clinical practice and provide benchmarks for audit.


Assuntos
Anestésicos Gerais , Doenças do Cão , Anestesia Geral/efeitos adversos , Anestesia Geral/veterinária , Animais , Estudos de Casos e Controles , Cães , Hipnóticos e Sedativos , Fatores de Risco , Reino Unido/epidemiologia
5.
Animals (Basel) ; 12(15)2022 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-35953928

RESUMO

This study compared four methods to provide intraoperative analgesia during canine ovariohysterectomy in a veterinary teaching hospital. A retrospective study was designed to assess the nociceptive response, cardiorespiratory stability, quality of recovery and complications of four analgesic protocols: epidural analgesia (EPIDURAL group), Quadratus Lumborum block (QLB group), Transversus Abdominis Plane block (TAP group), and just systemic analgesia (GENERAL group). Undergraduate students carried out all the loco-regional techniques under the direct supervision of a qualified anaesthetist. A total of 120 cases met the inclusion criteria and were included in the study and were distributed as follows: 22, 27, 32 and 39 cases with EPIDURAL, GENERAL, QLB and TAP groups, respectively. Data were analysed with statistical software R using different statistical methods. Significant differences among groups were defined as p < 0.05. Based on our results, all the groups needed the same number of rescue analgesia during the intra-operative period. The use of loco-regional techniques anticipated a better quality of recovery compared with the general group. The EPIDURAL group showed a statistically lower expired fraction of sevoflurane. No differences were found regarding complications. In conclusion, these four analgesic methods are suitable and safe to be performed for canine ovariohysterectomy, although loco-regional techniques might have some advantages.

7.
Animals (Basel) ; 11(12)2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34944201

RESUMO

Quadratus lumborum block (QLB) is used to provide analgesia for abdominal surgery in humans. The aim of this study was to assess an anaesthetic protocol involving the QLB for canine ovariohysterectomy. Ten dogs were included. Anaesthetic protocol consisted of premedication with IM medetomidine (20 µg kg-1) and SC meloxicam (0.1 mg kg-1), induction with propofol to effect, and maintenance with sevoflurane in oxygen/medical air. QLB was performed injecting 0.4 mL kg-1 of 0.25% bupivacaine/iohexol per side. Computed Tomography (CT) was performed before and after surgery. Fentanyl was administered as rescue analgesia during surgery. The Short Form of The Glasgow Composite Pain Scale and thermal threshold (TT) at the level of the elbow, T10, T13 and L3 were assessed before premedication and every hour postoperatively. Methadone was given as rescue analgesia postoperatively when pain score was >3. A Yuen's test on trimmed means for dependent samples was used to analyse the data (p < 0.05). CT images showed spreading of the contrast/block for a median (range) of 3 (2-5) vertebrae, without differences between preoperative and postoperative images. One dog needed rescue analgesia during surgery. Pain score was less than 4/24 in all the animals during the first 4 h after surgery. TT showed a significant increased signal in all the areas tested, apart from the humerus, 30 min after surgery. The QLB may provide additional analgesia for canine ovariohysterectomy. Further studies are needed to assess the specific contribution of the QLB in abdominal analgesia.

8.
Animals (Basel) ; 11(10)2021 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-34679966

RESUMO

Ultrasound-guided quadratus lumborum block (QLB) is a locoregional technique described in canine cadavers. The aim of this study was to assess a modified approach to QLB to minimise potential complications such as abdominal organ puncture. Nine canine cadavers were included and were positioned in lateral recumbency. An ultrasound-guided QLB was performed on each side. The probe was placed in the transverse position over the lumbar muscles just caudal to the last rib, and a needle was advanced in-plane from a dorso-lateral to a ventro-medial. A volume of 0.2 mL kg-1 of a mixture of iomeprol and methylene blue was injected. Computed tomography (CT) and dissection were performed to evaluate the spreading. Success was defined as staining of the nerve with a length of more than 0.6 cm. Potential complications such as intra-abdominal, epidural, or intravascular spreading of the mixture were also assessed. The CT images showed a T13 to L7 vertebra distribution, with a median of 5 (3-6). Dissection showed staining of the nerves from T13 to L4, with a median of 3 (2-5). No complications were found. This modified approach to QLB is safe and shows similar results to the previous studies in canine carcass.

11.
Proc Natl Acad Sci U S A ; 118(20)2021 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-33972441

RESUMO

Neuromodulation of immune function by stimulating the autonomic connections to the spleen has been demonstrated in rodent models. Consequently, neuroimmune modulation has been proposed as a new therapeutic strategy for the treatment of inflammatory conditions. However, demonstration of the translation of these immunomodulatory mechanisms in anatomically and physiologically relevant models is still lacking. Additionally, translational models are required to identify stimulation parameters that can be transferred to clinical applications of bioelectronic medicines. Here, we performed neuroanatomical and functional comparison of the mouse, rat, pig, and human splenic nerve using in vivo and ex vivo preparations. The pig was identified as a more suitable model of the human splenic innervation. Using functional electrophysiology, we developed a clinically relevant marker of splenic nerve engagement through stimulation-dependent reversible reduction in local blood flow. Translation of immunomodulatory mechanisms were then assessed using pig splenocytes and two models of acute inflammation in anesthetized pigs. The pig splenic nerve was shown to locally release noradrenaline upon stimulation, which was able to modulate cytokine production by pig splenocytes. Splenic nerve stimulation was found to promote cardiovascular protection as well as cytokine modulation in a high- and a low-dose lipopolysaccharide model, respectively. Importantly, splenic nerve-induced cytokine modulation was reproduced by stimulating the efferent trunk of the cervical vagus nerve. This work demonstrates that immune responses can be modulated by stimulation of spleen-targeted autonomic nerves in translational species and identifies splenic nerve stimulation parameters and biomarkers that are directly applicable to humans due to anatomical and electrophysiological similarities.


Assuntos
Sistema Imunitário/inervação , Imunomodulação/efeitos dos fármacos , Baço/imunologia , Sistema Nervoso Simpático/imunologia , Nervo Vago/imunologia , Animais , Feminino , Expressão Gênica , Humanos , Sistema Imunitário/efeitos dos fármacos , Inflamação , Interleucina-6/genética , Interleucina-6/imunologia , Lipopolissacarídeos/farmacologia , Camundongos , Microcirculação/efeitos dos fármacos , Microcirculação/genética , Microcirculação/imunologia , Norepinefrina/farmacologia , Ratos , Especificidade da Espécie , Baço/efeitos dos fármacos , Baço/inervação , Baço/patologia , Suínos , Sistema Nervoso Simpático/efeitos dos fármacos , Fator de Necrose Tumoral alfa/genética , Fator de Necrose Tumoral alfa/imunologia , Nervo Vago/efeitos dos fármacos , Estimulação do Nervo Vago/métodos
12.
J Vet Sci ; 22(2): e22, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33774938

RESUMO

BACKGROUND: Standing surgery in horses combining intravenous sedatives, analgesics and local anaesthesia is becoming more popular. Ultrasound guided (USG) peribulbar nerve block (PB) has been described in dogs and humans for facial and ocular surgery, reducing the risk of complications versus retrobulbar nerve block (RB). OBJECTIVE: To describe a technique for USG PB in horse cadavers. METHODS: Landmarks and PB technique were described in two equine cadaver heads (Phase 1), with computed tomography (CT) imaging confirming contrast location and spread. In Phase 2, ten equine cadaver heads were randomised to two operators naïve to the USG PB, with moderate experience with ultrasonography and conventional "blind" RB. Both techniques were demonstrated once. Subsequently, operators performed five USG PB and five RB each, unassisted. Contrast location and spread were evaluated by CT. Injection site success was defined for USG PB as extraconal contrast, and for RB intraconal contrast. RESULTS: Success was 10/10 for USG PB and 0/10 for RB (p < 0.001). Of the RB injections, eight resulted in extraconal contrast and two in the masseter muscle (p = 0.47). CONCLUSIONS: The USG PB had a high injection site success rate compared with the RB technique; however, we cannot comment on clinical effect. The USG technique was easily learnt, and no potential complications were seen. The USG PB nerve block could have a wide application for use in horses for ocular surgeries (enucleations, eyelid, corneal, cataract surgeries, and ocular analgesia) due to reduced risk of iatrogenic damage. Further clinical studies are needed.


Assuntos
Bloqueio Nervoso/veterinária , Tomografia Computadorizada por Raios X/veterinária , Animais , Cadáver , Meios de Contraste/análise , Cabeça , Cavalos , Bloqueio Nervoso/métodos , Variações Dependentes do Observador
13.
J Neurosci Methods ; 352: 109079, 2021 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-33516735

RESUMO

BACKGROUND: Neuromodulation by electrical stimulation of the human cervical vagus nerve may be limited by adverse side effects due to stimulation of off-target organs. It may be possible to overcome this by spatially selective stimulation of peripheral nerves. Preliminary studies have shown this is possible using a cylindrical multielectrode human-sized nerve cuff in vagus nerve selective neuromodulation. NEW METHOD: The model-based optimisation method for multi-electrode geometric design is presented. The method was applied for vagus nerve cuff array and suggested two rings of 14 electrodes, 3 mm apart, with 0.4 mm electrode width and separation and length 0.5-3 mm, with stimulation through a pair in the same radial position on the two rings. The electrodes were fabricated using PDMS-embedded stainless steel foil and PEDOT: pTS coating. RESULTS: In the cervical vagus nerve in anaesthetised sheep, it was possible to selectively reduce the respiratory breath rate (RBR) by 85 ± 5% without affecting heart rate, or selectively reduce heart rate (HR) by 20 ± 7% without affecting respiratory rate. The cardiac- and pulmonary-specific sites on the nerve cross-sectional perimeter were localised with a radial separation of 105 ± 5 degrees (P < 0.01, N = 24 in 12 sheep). CONCLUSIONS: Results suggest organotopic or function-specific organisation of neural fibres in the cervical vagus nerve. The optimised electrode array demonstrated selective electrical neuromodulation without adverse side effects. It may be possible to translate this to improved treatment by electrical autonomic neuromodulation for currently intractable conditions.


Assuntos
Estimulação do Nervo Vago , Animais , Estudos Transversais , Estimulação Elétrica , Eletrodos Implantados , Ovinos , Nervo Vago
14.
Vet Anaesth Analg ; 48(2): 272-276, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33341361

RESUMO

OBJECTIVE: To describe a novel in-plane ultrasound (U/S)-guided temporal approach to peribulbar block in dogs. STUDY DESIGN: Prospective experimental cadaver study. ANIMALS: A group of 10 Beagle cadavers. METHODS: After describing the U/S anatomy, peribulbar injection was performed bilaterally in 10 thawed Beagle cadavers by two randomly assigned operators. A 5-8 MHz microconvex U/S probe was positioned caudal to the orbital ligament in the longitudinal plane. Using an in-plane technique, methylene blue dye was injected in five dogs (10 eyes total), while methylene blue dye and iohexol contrast mixture (50:50) were injected in the remaining five dogs. Injection volume was 0.2 mL cm-1 of cranial length. A computed tomography (CT) scan was performed on dogs injected with dye and contrast to identify spread of contrast. Dissection to visualize dye spread in the orbit was performed in all dogs. Injection success was defined as spread of contrast into the peribulbar space. The pattern of distribution of contrast-dye was also assessed. Comparisons between operator and bilateral injections were assessed using a Student t test (p < 0.05). All other data are reported as number (n/N) and percentage (%). RESULTS: Peribulbar spread was noted in 19/20 injections (95%) on dissection. CT imaging (five dogs) illustrated peribulbar contrast spread in 9/10 injections (90%), with mixed peribulbar/retrobulbar spread for the remaining injection. Contrast was present at the rostral alar foramen in 4/10 (40%) injections, orbital fissure in 5/10 (50%), oval foramen in 1/10 (10%), maxillary nerve in 3/10 (30%) and intracranial in 5/10 (50%). Coverage of the maxillary nerve was noted on 3/20 (15%) injections on dissection. No further dye spread was noted. CONCLUSIONS AND CLINICAL RELEVANCE: This technique demonstrated peribulbar spread of injectate in 100% of injections for the 10 canine cadavers studied. Further studies are required to evaluate this technique clinically.


Assuntos
Doenças do Cão , Bloqueio Nervoso , Animais , Cadáver , Cães , Bloqueio Nervoso/veterinária , Estudos Prospectivos , Ultrassonografia , Ultrassonografia de Intervenção/veterinária
15.
Vet Anaesth Analg ; 48(1): 125-133, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33334690

RESUMO

OBJECTIVE: To examine the anatomy of the lumbar epaxial region and to describe two different ultrasound-guided approaches for the lumbar erector spinae plane (ESP) block in dogs. STUDY DESIGN: An anatomical and experimental cadaver study. ANIMALS: A group of 19 canine cadavers. METHODS: The anatomy was described following dissection of two cadavers. Bilateral ultrasound-guided ESP injections with 0.4 mL kg-1 of contrast dye were performed in 17 adult Beagle cadavers using either transversal (TVS) or parasagittal (PST) approaches. Computed tomography was performed to measure the total length of the contrast dye column and the epidural, intravascular, hypaxial and intra-abdominal migration. Dissections were performed to assess the spread of the contrast dye and to determine the degree of staining of the dorsal branches of the spinal nerves (DBSN). Mann-Whitney U and chi-square tests were used to compare data between groups. RESULTS: Using both techniques, the contrast dye was observed within the ESP compartment. There was no difference in the total length of the contrast dye column between TVS and PST approaches (p = 0.056). Using the TVS approach, multisegmental staining of the DBSN was visible with 100% (17/17) of injections, while complete staining of the DBSN was achieved at 94% of the injection sites. Using the PST approach, these values were 29% (5/17) and 23% (4/17), respectively. The TVS approach stained more DBSN than the PST approach (p = 0.001), with a median (range) of 2 (2-3) versus 0 (0-3) DBSN, respectively. Using the TVS approach, epidural and intravascular migration were present in 2/17 (p = 0.485) and 3/17 (p = 0.227) injections, respectively. CONCLUSIONS AND CLINICAL RELEVANCE: Both ultrasound-guided approaches resulted in a spread of the contrast dye within the ESP compartment. Although there were no differences in the total length of the contrast dye column, the TVS approach was superior to the PST approach in staining DBSN.


Assuntos
Doenças do Cão , Bloqueio Nervoso , Animais , Cadáver , Cães , Bloqueio Nervoso/veterinária , Músculos Paraespinais/diagnóstico por imagem , Vértebras Torácicas/diagnóstico por imagem , Ultrassonografia de Intervenção/veterinária
16.
Sci Rep ; 9(1): 18136, 2019 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-31792232

RESUMO

Recent research supports that over-activation of the carotid body plays a key role in metabolic diseases like type 2 diabetes. Supressing carotid body signalling through carotid sinus nerve (CSN) modulation may offer a therapeutic approach for treating such diseases. Here we anatomically and histologically characterised the CSN in the farm pig as a recommended path to translational medicine. We developed an acute in vivo porcine model to assess the application of kilohertz frequency alternating current (KHFAC) to the CSN of evoked chemo-afferent CSN responses. Our results demonstrate the feasibility of this approach in an acute setting, as KHFAC modulation was able to successfully, yet variably, block evoked chemo-afferent responses. The observed variability in blocking response is believed to reflect the complex and diverse anatomy of the porcine CSN, which closely resembles human anatomy, as well as the need for optimisation of electrodes and parameters for a human-sized nerve. Overall, these results demonstrate the feasibility of neuromodulation of the CSN in an anesthetised large animal model, and represent the first steps in driving KHFAC modulation towards clinical translation. Chronic recovery disease models will be required to assess safety and efficacy of this potential therapeutic modality for application in diabetes treatment.


Assuntos
Seio Carotídeo/inervação , Animais , Corpo Carotídeo/efeitos dos fármacos , Corpo Carotídeo/fisiologia , Seio Carotídeo/anatomia & histologia , Seio Carotídeo/efeitos dos fármacos , Eletrodos Implantados , Feminino , Humanos , Condução Nervosa , Respiração , Cianeto de Sódio/farmacologia , Suínos
17.
Vet Anaesth Analg ; 46(2): 246-250, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30713055

RESUMO

OBJECTIVE: To describe a novel ultrasound-guided posterior extraconal block in the dog. STUDY DESIGN: Prospective experimental cadaveric study. ANIMALS: A total of 13 Beagle Cross cadaver heads. METHODS: After describing the ultrasound bony landmarks and posterior extraconal local regional technique in one head, 12 heads were used to evaluate the spreading of contrast and evaluate potential complications. A 5-8 MHz microconvex ultrasound probe was positioned caudal to the orbital ligament, with the beam orientated transversely, and then tilted caudally until the orbital fissure was visualized. After identifying the bony structures consistent with the orbital fissure, a needle was advanced using an in-plane technique and 0.5 mL of a 50:50 mixture of iohexol and methylene blue was injected. Computed tomography (CT) and dissection were used to evaluate successful injections and potential complications. The injection was considered successful if radiopaque contrast medium was 5 mm from the orbital fissure. Potential complications were defined as the presence of radiopaque contrast within the globe or the intracalvarial tissues. RESULTS: The CT images confirmed contrast at the target site in 15/24 (63%) of the injections. Only two injections were found in the temporalis muscle; the rest of the injections were located in the extraconal space. No potential complications such as intracranial spreading of contrast, intravascular or intraocular injection were found. CONCLUSIONS AND CLINICAL RELEVANCE: The technique can deliver contrast close to the main nerves which provide sensory and motor innervation to the eye. Further studies are needed to evaluate this technique in clinical cases.


Assuntos
Cães/fisiologia , Bloqueio Nervoso/veterinária , Órbita/inervação , Animais , Cadáver , Procedimentos Cirúrgicos Oftalmológicos/veterinária , Estudos Prospectivos , Ultrassonografia de Intervenção/veterinária
18.
J Feline Med Surg ; 21(4): 347-352, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-29848149

RESUMO

OBJECTIVES: The aim of this study was to describe the anaesthetic management and perianaesthetic complications encountered during hypophysectomy surgery in acromegalic cats. We explored relationships between animal demographic data, the anaesthetic protocol used and presence of perioperative complications. METHODS: Cats having undergone hypophysectomy surgery for the treatment of feline acromegaly at a single veterinary referral hospital were identified from hospital records. The anaesthesia records and clinical notes of these animals were retrospectively reviewed. Descriptive statistics were produced and binary logistic regression run to assess for any relationship between patient factors, anaesthetic management and complications during the perioperative period. RESULTS: Perianaesthetic complications identified included hypothermia, hypotension, bradycardia and airway obstruction. Mortality at 24 h post-anaesthesia was 8%. The use of alpha (α)2 agonists was associated with a lower incidence of hypotension. Fentanyl infusion was associated with a higher incidence of airway obstruction compared with remifentanil. Subjectively assessed anaesthetic recovery quality had an association with the number of days spent in the intensive care ward postoperatively. CONCLUSIONS AND RELEVANCE: The anaesthetic management described seems effective for hypophysectomy surgery in cats. Intraoperative complications were common and, while not apparently associated with 24 h patient outcome, drugs and equipment to manage these complications should be available.


Assuntos
Acromegalia , Anestesia , Doenças do Gato/cirurgia , Hipofisectomia , Complicações Intraoperatórias/veterinária , Acromegalia/cirurgia , Acromegalia/veterinária , Anestesia/métodos , Anestesia/veterinária , Anestésicos , Animais , Gatos , Hipofisectomia/efeitos adversos , Hipofisectomia/métodos , Estudos Retrospectivos
19.
Open Vet J ; 9(3): 230-237, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31998616

RESUMO

Background: The caudal thoracic paravertebral (CTPV) block is a regional anesthesia technique currently used in human medicine to provide analgesia in abdominal surgical procedures. Aim: The objectives of this study are to describe an ultrasound-guided technique to place catheters in CTPV space in canine cadavers and evaluate the distribution of a 50:50 contrast-dye solution administered through them. Methods: Eight thawed adult beagle cadavers (9.2 ± 2.0 kg body total weight) were used. Thirteen catheters were placed. In the first phase, a volume of 0.3 ml kg-1 of the contrast-dye was administered in all cases. After the injections, computed tomography (CT) scans were carried out to assess the distribution of the contrast-dye. In the second phase, an extra 0.2 ml kg-1 of the contrast-dye was administered through eight catheters, followed by a second CT scan. Two cadavers were dissected to assess the distribution of the contrast-dye. The injection site varied between T8-9 and T12-13. Results: The evaluation of the CT scans showed contrast-dye within the paravertebral space in 92% (12/13) of the injections. The distribution pattern observed after the injections performed within the TPV space was linear and intercostal in all cases. The median (range) linear spread of the contrast was 7 (5-10) spinal nerves and involved 3 (2-8) intercostal spaces. The contrast-dye reached lumbar regions in 42% of the injections (5/12). A larger spread of the contrast-dye was not observed after the administration of a second dose of the injectate. No signs of epidural, intrapleural/intrapulmonary, intravascular, or intraabdominal spread were observed. The dissection of the two cadavers confirmed the spread of the contrast-dye along the sympathetic trunk and intercostal spaces. Conclusion: The administration of 0.3 ml kg-1 of the contrast-dye in the CTPV space resulted in a distribution compatible with the block of nerves responsible for the innervation of the majority of the abdominal viscera and cranial abdominal wall.


Assuntos
Cateterismo/veterinária , Bloqueio Nervoso/veterinária , Vértebras Torácicas/cirurgia , Ultrassonografia/veterinária , Animais , Cadáver , Cateterismo/métodos , Cães , Espaço Epidural/cirurgia , Bloqueio Nervoso/métodos
20.
J Neural Eng ; 16(1): 016001, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30444215

RESUMO

OBJECTIVE: Non-invasive imaging techniques are undoubtedly the ideal methods for continuous monitoring of neural activity. One such method, fast neural electrical impedance tomography (EIT) has been developed over the past decade in order to image neural action potentials with non-penetrating electrode arrays. APPROACH: The goal of this study is two-fold. First, we present a detailed fabrication method for silicone-based multiple electrode arrays which can be used for epicortical or neural cuff applications. Secondly, we optimize electrode material coatings in order to achieve the best accuracy in EIT reconstructions. MAIN RESULTS: The testing of nanostructured electrode interface materials consisting of platinum, iridium oxide, and PEDOT:pTS in saline tank experiments demonstrated that the PEDOT:pTS coating used in this study leads to more accurate reconstruction dimensions along with reduced phase separation between recording channels. The PEDOT:pTS electrodes were then used in vivo to successfully image and localize the evoked activity of the recurrent laryngeal fascicle from within the cervical vagus nerve. SIGNIFICANCE: These results alongside the simple fabrication method presented here position EIT as an effective method to image neural activity.


Assuntos
Impedância Elétrica , Desenho de Equipamento/métodos , Nervos Laríngeos/diagnóstico por imagem , Nervos Laríngeos/fisiologia , Microeletrodos , Tomografia/métodos , Animais , Feminino , Microeletrodos/normas , Sistema Nervoso Periférico/diagnóstico por imagem , Sistema Nervoso Periférico/fisiologia , Ovinos , Silicones , Tomografia/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA