Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Quant Imaging Med Surg ; 14(6): 3951-3958, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38846305

RESUMO

Background: With the increase of pancreatic tumor patients in recent years, there is an urgent need to find a way to treat pancreatic tumors. Surgery is one of the best methods for the treatment of pancreatic tumors, the success of which depends on the evaluation of peripancreatic vessels before surgery. Computed tomography (CT), as a non-invasive, fast, and economical auxiliary examination method, is undoubtedly one of the best means of clinical auxiliary examination. In this study, we investigated the impact of single-energy spectral CT imaging on the image quality of peripancreatic blood vessels and the clinical value of low-keV imaging in enhancing the image quality of peripancreatic arteriovenous vessels. Methods: We prospectively enrolled 103 patients who underwent abdominal vascular-enhanced CT examinations at the Affiliated Hospital of Hebei University between December 2022 and May 2023 and who were all scanned with the dual-energy feature on the United Imaging ATLAS scanner. The images were reconstructed at 70 keV, mixed energy, and optimized single energy in the post-processing station of United Imaging Healthcare Technology Co., Ltd. The CT value and contrast-to-noise ratio (CNR) of the superior mesenteric artery (SMA), gastroduodenal artery (GDA), inferior pancreaticoduodenal artery (IPDA), and superior mesenteric vein (SMV) were compared across energy levels, and then the image quality was subjectively evaluated. One-way analysis of variance and rank-sum tests were utilized for the statistical analysis. Results: The CT values of SMA, GDA, IPDA, and SMV in the optimal single energy group were 358.37±70.24, 323.36±88.23, 300.76±76.27, and 257.74±20.56 Hounsfield unit (HU), respectively, which were superior to those in the mixed energy (241.66±47.69, 235.17±53.71, 207.36±45.17, and 187.39±23.21 HU) and 70 keV groups (260.89±54.27, 252.41±58.87, 223.17±43.65, and 203.18±18.17 HU) (P<0.05). The diagnostic efficacy was greater in the optimal single energy group than in the other 2 groups (4.63±0.50, 3.91±0.57, and 4.23±0.83) (P<0.05). Conclusions: The optimal single energy for showing peripancreatic blood vessels is 62±7 keV when utilizing single-energy spectral CT imaging.

2.
Am J Transl Res ; 15(5): 3267-3278, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37303654

RESUMO

OBJECTIVE: To assess the effectiveness of susceptibility-weighted imaging (SWI) in displaying the superior petrosal vein complex (SPVC) and the role of venous three-dimensional (3D) reconstruction in visualizing the anatomical relationship in patients with trigeminal neuralgia (TN). METHODS: A total of 30 patients with primary TN who received treatment between September 2019 and December 2020 were enrolled prospectively in this study. All patients were examined with fast imaging employing steady-state acquisition (Fiesta), three-dimensional time of flight (3D-TOF) and SWI by the same technician. Image analysis was performed by 2 physicians. 3D reconstruction of nerves, arteries, and veins was performed with 3dslicer and compared with intraoperative findings. The general characteristics, vein description in MRI, and the composition of SPVC types were also compared. RESULTS: The display effect of SPVC in SWI was significantly better than that in Fiesta and 3D-TOF (P < 0.05). The display effect of phase images was found to be superior to magnitude images (P < 0.05). The superior petrosal vein, pontotrigeminal vein, transverse pontine vein, and vein of the cerebellopontine fissure were clearly displayed in SWI. The anatomical relationship between SPVC and trigeminal nerve shown by 3D reconstruction of the vein was consistent with the findings observed during the operation. CONCLUSION: The SPVC can be clearly displayed by SWI. 3D reconstruction of the vein can accurately display the anatomical relationship between the trigeminal nerve and SPVC.

3.
Jpn J Radiol ; 41(6): 669-679, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36607550

RESUMO

PURPOSE: To conduct a comparative study of image quality, radiation dose, and iodine intake in hepatic computed tomographic angiography (CTA) of overweight patients with different Gemstone Spectral Imaging (GSI) noise indexes combined with different concentrations of contrast medium. MATERIALS AND METHODS: Ninety patients with a body mass index of ≥ 25 kg/m2 were divided into three groups (A, B and C), each with 30 patients. The three groups underwent hepatic CTA with different NI of 7, 11 and 15, respectively, and were injected with different iodine concentrations of 370, 350 and 320 mgI/mL, respectively. Five sets of images at 40-60 keV (interval, 5 keV) were reconstructed in each group. The CT value, image noise, contrast-to-noise ratio (CNR) and subjective score of the hepatic artery and vein, and portal vein in different monochromatic image sets were analyzed to select the optimal energy level in each group. The differences in CT value, image noise, CNR and a subjective score of hepatic artery and vein, portal vein in the optimal monochromatic images among the three groups were compared, the volume CT dose index (CTDIvol) and dose-length product (DLP) were recorded, and the effective dose and iodine intake were calculated. RESULTS: The 40 keV was determined to be the optimal energy level for the monochromatic image sets in each group. No significant group differences were noted in the CT value, image noise, CNR, and subjective image scores of the hepatic artery and vein, and portal vein for the optimal monochromatic images (P > 0.05). Compared with group A, the effective dose and iodine intake in group B were reduced by 50.18% and 9.3%, and by 58.12% and 14.23% in group C, respectively. CONCLUSION: A low-concentration contrast medium combined with a high-noise GSI index in hepatic CTA of overweight patients can reduce the radiation dose and iodine intake while ensuring image quality.


Assuntos
Angiografia por Tomografia Computadorizada , Iodo , Humanos , Angiografia por Tomografia Computadorizada/métodos , Estudos de Viabilidade , Sobrepeso/diagnóstico por imagem , Doses de Radiação , Meios de Contraste , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
4.
ISME J ; 16(11): 2513-2524, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35908110

RESUMO

Root microbiota is important for plant growth and fitness. Little is known about whether and how the assembly of root microbiota may be controlled by epigenetic regulation, which is crucial for gene transcription and genome stability. Here we show that dysfunction of the histone demethylase IBM1 (INCREASE IN BONSAI METHYLATION 1) in Arabidopsis thaliana substantially reshaped the root microbiota, with the majority of the significant amplicon sequence variants (ASVs) being decreased. Transcriptome analyses of plants grown in soil and in sterile growth medium jointly disclosed salicylic acid (SA)-mediated autoimmunity and production of the defense metabolite camalexin in the ibm1 mutants. Analyses of genome-wide histone modifications and DNA methylation highlighted epigenetic modifications permissive for transcription at several important defense regulators. Consistently, ibm1 mutants showed increased resistance to the pathogen Pseudomonas syringae DC3000 with stronger immune responses. In addition, ibm1 showed substantially impaired plant growth promotion in response to beneficial bacteria; the impairment was partially mimicked by exogenous application of SA to wild-type plants, and by a null mutation of AGP19 that is important for cell expansion and that is repressed with DNA hypermethylation in ibm1. IBM1-dependent epigenetic regulation imposes strong and broad impacts on plant-microbe interactions and thereby shapes the assembly of root microbiota.


Assuntos
Proteínas de Arabidopsis , Arabidopsis , Microbiota , Arabidopsis/genética , Proteínas de Arabidopsis/genética , Proteínas de Arabidopsis/metabolismo , Autoimunidade , DNA , Metilação de DNA , Epigênese Genética , Regulação da Expressão Gênica de Plantas , Histona Desmetilases/genética , Histona Desmetilases/metabolismo , Histona Desmetilases com o Domínio Jumonji/genética , Histona Desmetilases com o Domínio Jumonji/metabolismo , Mutação , Doenças das Plantas , Pseudomonas syringae/genética , Pseudomonas syringae/metabolismo , Ácido Salicílico/metabolismo , Solo
5.
J Xray Sci Technol ; 30(4): 689-696, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35527624

RESUMO

OBJECTIVES: To compare image quality and radiation dose of computed tomography angiography (CTA) of the head and neck in patients using two Gemstone Spectral Imaging (GSI) scanning protocols. METHODS: A total of 100 patients who underwent head-neck CTA were divided into two groups (A and B) according to the scanning protocols, with 50 patients in each group. The patients in group A underwent GSI scanning protocol 1 (GSI profile: head and neck CTA), while those in group B underwent GSI scanning protocol 2 (GSI profile: chest 80 mm). All images were reconstructed using 40% and 70% pre- and post-adaptive level statistical iterative reconstruction V (pre-ASiR-V and post-ASiR-V) algorithms, respectively. The CT dose index (CTDIvol) and dose-length (DLP) product were recorded and the mean value was calculated and converted to the effective dose. CT values, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of all images were calculated. Additionally, subjective image evaluation was conducted by two independent radiologists using a five-point scoring method. All data were statistically analyzed. RESULTS: There were no significant differences in the CT values, SNR, CNR, and subjective score between groups A and B (p > 0.05); however, the mean effective dose (1.2±0.1 mSv) in group B was 45.5% lower than that in group A (2.2±0.2 mSv) (p < 0.05). CONCLUSIONS: GSI scanning protocol 2 could more effectively reduce the radiation dose in head-neck CT angiography while maintaining image quality compared to GSI scanning protocol 1.


Assuntos
Angiografia por Tomografia Computadorizada , Interpretação de Imagem Radiográfica Assistida por Computador , Algoritmos , Cabeça , Humanos , Doses de Radiação , Razão Sinal-Ruído
6.
J Integr Plant Biol ; 64(6): 1135-1139, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35377511

RESUMO

Premature plant senescence induced by abiotic stresses is a major cause of agricultural losses worldwide. Tools for suppressing stress-induced plant senescence are limited. Here, we report that diacetyl, a natural compound emitted by the plant-beneficial bacterium Bacillus amyloliquefaciens, suppresses abscisic acid -mediated foliar senescence in Arabidopsis thaliana under various abiotic stress conditions. Our results establish diacetyl as an effective protector against stress-induced plant senescence and reveal a molecular mechanism for bacteria-enhanced plant stress resistance.


Assuntos
Proteínas de Arabidopsis , Arabidopsis , Ácido Abscísico/farmacologia , Arabidopsis/metabolismo , Proteínas de Arabidopsis/metabolismo , Bactérias , Diacetil/farmacologia , Regulação da Expressão Gênica de Plantas , Folhas de Planta/metabolismo , Plantas/metabolismo , Estresse Fisiológico
7.
Curr Med Imaging ; 18(7): 757-763, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35040416

RESUMO

BACKGROUND AND AIM: The study aims to investigate the feasibility of further radiation dose reduction via the application of a high iodine delivery rate combined with automatic current modulation technology (high noise index) in head and neck computed tomography angiography. METHODS: Sixty-four patients who underwent routine head and neck computed tomographic angiography were randomly divided into two groups: a low-dose group of 32 cases and an ultra-low-dose group of 32 cases. The same image reconstruction technique was applied in both groups using the 50% adaptive statistical iterative reconstruction method. Quantitative and qualitative image quality assessment of the carotid artery, computed tomographic dose index volume, dose length product, and effective dose of the two groups were analyzed. RESULTS: The two groups were not significantly (P>0.05) different in age, gender, and body mass index. Significant (P<0.001) reduction of radiation dose was observed in all the parameters of computed tomographic dose index volume (18.12%), dose length product (19.91%), and effective dose (19.84%) in the ultra-low-dose group. Quantitative and qualitative image assessment produced similar results between the two groups, except for the higher mean vascular computed tomographic values found in the ultra-low dose group. CONCLUSION: Application of a higher iodine delivery rate combined with automatic current modulation technology (high noise index) in an existing low tube voltage protocol can further decrease the radiation dose and the total volume of contrast agent while maintaining similar image quality for patients undergoing computed tomography angiography of the head and neck, which can be recommended as the conventional scanning method.


Assuntos
Angiografia por Tomografia Computadorizada , Doses de Radiação , Angiografia , Angiografia por Tomografia Computadorizada/métodos , Redução da Medicação , Humanos , Iodo , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Razão Sinal-Ruído
8.
Int J Mol Sci ; 23(1)2021 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-35008551

RESUMO

Grain weight and size are important traits determining grain yield and influencing grain quality in rice. In a previous study, a quantitative trait locus controlling thousand-grain weight (TGW) in rice, qTGW10-20.8, was mapped in a 70.7 kb region on chromosome 10. Validation of the candidate gene for qTGW10-20.8, OsMADS56 encoding a MADS-box transcription factor, was performed in this study. In a near-isogenic line (NIL) population segregated only at the OsMADS56 locus, NILs carrying the OsMADS56 allele of IRBB52 were 1.9% and 2.9% lower in TGW than NILs carrying the OsMADS56 allele of Teqing in 2018 and 2020, respectively. Using OsMADS56 knock-out mutants and overexpression transgenic plants, OsMADS56 was validated as the causal gene for qTGW10-20.8. Compared with the recipients, the TGW of the knock-out mutants was reduced by 6.0-15.0%. In these populations, decreased grain weight and size were associated with a reduction in the expression of OsMADS56. In transgenic populations of OsMADS56 driven by a strong constitutive promoter, grain weight and size of the positive plants were significantly higher than those of the negative plants. Haplotype analysis showed that the Teqing-type allele of OsMADS56 is the major type presented in cultivated rice and used in variety improvement. Cloning of OsMADS56 provides a new gene resource to improve grain weight and size through molecular design breeding.


Assuntos
Grão Comestível/genética , Genes de Plantas/genética , Oryza/genética , Mapeamento Cromossômico/métodos , Cromossomos de Plantas/genética , Fenótipo , Estruturas Vegetais/genética , Plantas Geneticamente Modificadas/genética , Locos de Características Quantitativas/genética
9.
Biosensors (Basel) ; 9(2)2019 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-31117228

RESUMO

Bacteria in the genus Brucella are the cause of brucellosis in humans and many domestic and wild animals. A rapid and culture-free detection assay to detect Brucella in clinical samples would be highly valuable. Nanomaterial optical fiber biosensors (NOFS) are capable of recognizing DNA hybridization events or other analyte interactions with high specificity and sensitivity. Therefore, a NOFS assay was developed to detect Brucella DNA from cultures and in tissue samples from infected mice. An ionic self-assembled multilayer (ISAM) film was coupled to a long-period grating optical fiber, and a nucleotide probe complementary to the Brucella IS711 region and modified with biotin was bound to the ISAM by covalent conjugation. When the ISAM/probe duplex was exposed to lysate containing ≥100 killed cells of Brucella, or liver or spleen tissue extracts from Brucella-infected mice, substantial attenuation of light transmission occurred, whereas exposure of the complexed fiber to non-Brucella gram-negative bacteria or control tissue samples resulted in negligible attenuation of light transmission. Oligonucleotide probes specific for B. abortus, B. melitensis, and B. suis could also be used to detect and differentiate these three nomenspecies. In summary, the NOFS biosensor assay detected three nomenspecies of Brucella without the use of polymerase chain reaction within 30 min and could specifically detect low numbers of this bacterium in clinical samples.


Assuntos
Técnicas Biossensoriais/métodos , Brucella/química , DNA Bacteriano/análise , Tecnologia de Fibra Óptica/métodos , Animais , Brucella/patogenicidade , Feminino , Fígado/microbiologia , Camundongos , Camundongos Endogâmicos BALB C , Nanoestruturas/química , Nanotecnologia/métodos , Baço/microbiologia
10.
J Vet Diagn Invest ; 30(6): 821-829, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30264658

RESUMO

Histophilus somni is an opportunistic pathogen responsible for respiratory and systemic diseases of cattle and sheep. Rapid and accurate detection of H. somni is essential to distinguish H. somni from other potential pathogens for proper control and treatment of infections. Nanomaterial optical fiber biosensors (NOFS) recognize analyte interactions, such as DNA hybridization, with high specificity and sensitivity, and were applied to detect H. somni DNA in culture and clinical samples. An ionic self-assembled multilayer (ISAM) film was fabricated on a long-period grating optical fiber, and a biotinylated, nucleotide probe complementary to the H. somni 16S rDNA gene was coupled to the ISAM film. Exposure of the ISAM::probe to ⩾100 killed cells of H. somni strain 2336 without DNA amplification resulted in attenuation of light transmission of ⩾9.4%. Exposure of the complexed fiber to Escherichia coli or non- H. somni species of Pasteurellaceae reduced light transmission by ⩽3.4%. Exposure of the ISAM::probe to blood, bronchoalveolar fluid, or spleen from mice or calves infected with H. somni resulted in ⩾24.3% transmission attenuation. The assay correctly detected all 6 strains of H. somni tested from culture, or tissues from 3 separate mice and calves tested in duplicate. Six heterologous strains (representing 6 genera) reacted at below the cutoff value of 4.87% attenuation of light transmission. NOFS detected at least 100 H. somni cells without DNA amplification within 45 min with high specificity. Although different fibers could vary in signal sensitivity, this did not affect the sensitivity or specificity of the assay.


Assuntos
Técnicas Biossensoriais/veterinária , Nanoestruturas/análise , Fibras Ópticas/veterinária , Infecções por Pasteurellaceae/veterinária , Pasteurellaceae/isolamento & purificação , Animais , Bovinos , DNA Bacteriano/análise , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Infecções por Pasteurellaceae/diagnóstico , Infecções por Pasteurellaceae/microbiologia , Sensibilidade e Especificidade
11.
Front Genet ; 9: 168, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29868116

RESUMO

There is increasing evidence suggesting the contribution of non-coding RNAs (ncRNAs) to the phenotypic and physiological complexity of organisms. A novel ncRNA species has been identified near the transcription boundaries of protein-coding genes in eukaryotes, bacteria, and archaea. This review provides a detailed description of these transcription boundary-associated RNAs (TBARs), including their classification. Based on their genomic distribution, TBARs are divided into two major groups: promoter-associated RNAs (PARs) and terminus-associated RNAs (TARs). Depending on the sequence length, each group is further classified into long RNA species (>200 nt) and small RNA species (<200 nt). According to these rules of TBAR classification, divergent ncRNAs with confusing nomenclatures, such as promoter upstream transcripts (PROMPTs), upstream antisense RNAs (uaRNAs), stable unannotated transcripts (SUTs), cryptic unstable transcripts (CUTs), upstream non-coding transcripts (UNTs), transcription start site-associated RNAs (TSSaRNAs), transcription initiation RNAs (tiRNAs), and transcription termination site-associated RNAs (TTSaRNAs), were assigned to specific classes. Although the biogenesis pathways of PARs and TARs have not yet been clearly elucidated, previous studies indicate that some of the PARs have originated either through divergent transcription or via RNA polymerase pausing. Intriguing findings regarding the functional implications of the TBARs such as the long-range "gene looping" model, which explains their role in the transcriptional regulation of protein-coding genes, are also discussed. Altogether, this review provides a comprehensive overview of the current research status of TBARs, which will promote further investigations in this research area.

12.
Radiol Med ; 123(9): 676-685, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29725914

RESUMO

OBJECTIVE: To investigate the differences in imaging quality and radiation dose in CT pulmonary angiography (CTPA) by organ dose modulation and 3D Smart mA modulation in different body mass indices (BMIs) with an adaptive statistical iterative reconstruction (ASiR-V) algorithm. METHODS: Three hundred female patients who underwent CTPA were equally divided into three groups: A (18.5 kg/m2 ≦ BMI < 24.9 kg/m2), B (24.9 kg/m2 ≦ BMI < 29.9 kg/m2) and C (29.9 kg/m2 ≦ BMI≦ 34.9 kg/m2). The groups were randomly subdivided into two subgroups (n = 50): A1-A2, B1-B2 and C1-C2. The patients in subgroups A1, B1 and C1 underwent organ dose modulation with the ASiR-V algorithm. The other patients underwent 3D Smart mA modulation. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of all images were calculated after CTPA. Images were then subjectively evaluated using a 5-point scale. The volume CT dose index and dose-length product (DLP) were recorded and their means calculated. The DLP was converted to the effective dose (ED). RESULTS: In group A, the SNR, CNR, and subjective image scores showed no statistical differences (P > 0.05). The ED in subgroup A1 was 33.36% lower than that in A2. In group B and C, the variables showed no significant differences between the subgroups B1 and B2 (P > 0.05), and the subgroups C1 and C2 (P > 0.05), respectively. The ED in subgroup B1 and C1 was 36.15 and 38.22% lower than that in B2 and C2, respectively. CONCLUSIONS: Using organ dose modulation and applying the ASiR-V algorithm can more effectively reduce the radiation dose in CTPA than in 3D Smart mA modulation, while maintaining image quality.


Assuntos
Algoritmos , Índice de Massa Corporal , Angiografia por Tomografia Computadorizada/métodos , Embolia Pulmonar/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Meios de Contraste , Feminino , Humanos , Imageamento Tridimensional , Pessoa de Meia-Idade , Distribuição Aleatória , Razão Sinal-Ruído , Ácidos Tri-Iodobenzoicos
13.
Jpn J Radiol ; 36(5): 345-350, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29616398

RESUMO

PURPOSE: To investigate the effect of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) technology in reducing radiation and contrast dosage. METHODS: Sixty-four patients were randomly divided into two groups for abdominal computed tomography (CT): the experiment group with ASIS plus 50% ASIR and the control with 120 kVp voltage. RESULTS: The CT dose-index volume decreased by 23.68 and 23.57% and the dose-length product dropped by 25.59 and 18.45% in the arterial and portal venous phases, respectively, in the experiment than control group. The contrast dose was reduced by 16.86% in the experiment group. In the 55 keV + 50% ASIR group, the arterial contrast-to-noise ratio and scores were significantly (P < 0.05) higher than in the control group in the arterial phase while the portal contrast-to-noise ratio and scores were not significantly different between the two groups (P > 0.05). CONCLUSION: The ASIS technique plus 50% ASIR can enhance image quality of the abdominal structures while decreasing the radiation and contrast dosage compared with the conventional scan mode.


Assuntos
Abdome/irrigação sanguínea , Abdome/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
14.
Brief Funct Genomics ; 17(3): 191-197, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29240875

RESUMO

Argonaute (AGO) protein family is highly conserved in eukaryotes and prokaryotes, reflecting its evolutionarily indispensible role in maintaining normal life cycle of the organisms. Small RNA-guided, AGO-dependent RNA interference (RNAi) is a well-studied pathway for gene expression regulation, which can be performed at transcriptional, posttranscriptional or translational level. In addition to RNAi, growing pieces of evidence point to a novel role of AGOs in pre-mRNA (messenger RNA precursor) splicing in animals. Many noncoding RNAs (ncRNAs) share common structural features with protein-coding genes, indicating that these ncRNAs might be subject to AGO-mediated splicing. Finally, we provide a comprehensive view that RNAi, transcription and RNA splicing are highly interactive processes, all of which involve several key factors such as AGOs. In this regard, the AGO proteins contribute to orchestrate an exquisite gene regulatory network in vivo. However, more research efforts are needed to reach a thorough understanding of the AGO activities.


Assuntos
Proteínas Argonautas/metabolismo , Interferência de RNA , Splicing de RNA/genética , Animais , Proteínas Argonautas/genética , Modelos Biológicos , RNA não Traduzido/genética , RNA não Traduzido/metabolismo , Transcrição Gênica
15.
Rice (N Y) ; 10(1): 38, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28786034

RESUMO

The next-generation sequencing (NGS) technology has revolutionized our previous understanding of the plant genomes, relying on its innate advantages, such as high throughput and deep sequencing depth. In addition to the protein-coding gene loci, massive transcription signals have been detected within intergenic or intragenic regions. Most of these signals belong to non-coding ones, considering their weak protein-coding potential. Generally, these transcripts could be divided into long non-coding RNAs and small non-coding RNAs (sRNAs) based on their sequence length. In addition to the well-known microRNAs (miRNAs), many plant endogenous sRNAs were collectively referred to as small interfering RNAs. However, an increasing number of unclassified sRNA species are being discovered by NGS. The high heterogeneity of these novel sRNAs greatly hampered the mechanistic studies, especially on the clear description of their biogenesis and action pathways. Fortunately, public databases, bioinformatics softwares and NGS datasets are increasingly available for plant sRNA research. Here, by summarizing these valuable resources, we proposed a general workflow to decipher the RDR (RNA-dependent RNA polymerase)- and DCL (Dicer-like)-dependent biogenesis pathways, and the Argonaute-mediated action modes (such as target cleavages and chromatin modifications) for specific sRNA species in plants. Taken together, we hope that by summarizing a list of the public resources, this work will facilitate the plant biologists to perform classification and functional characterization of the interesting sRNA species.

16.
J Xray Sci Technol ; 2017 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-28387698

RESUMO

OBJECTIVES: Since body mass index (BMI) affects medical imaging quality or noise due to penetration of the radiation through bodies with varying sizes, this study aims to investigate and determine the optimal BMI-adjusted noise index (NI) setting on the contrast-enhanced liver CT scans obtained using 3D Smart mA technology with adaptive statistical iterative reconstruction (ASIR 2.0) algorithm. MATERIALS AND METHODS: A total of 320 patients who had contrast-enhanced liver CT scans were divided into two equal-sized groups: A (18.5 kg/m2≤BMI<24.9 kg/m2) and B (24.9 kg/m2 ≤ BMI ≤34.9 kg/m2). The two groups were randomly divided into four subgroups with an NI of 11, 13, 15, and 17. All images were reconstructed with 50% ASIR 2.0. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated after the late arterial, portal venous, and equilibrium phases were completed. Images were evaluated by two radiologists using a subjective 0 -5 scale. Mean CT dose index of volume, dose-length product, and effective dose (ED) were calculated and compared using one-way ANOVA. RESULTS: In group A, the best-quality images obtained at the lowest ED were scanned at an NI of 15 in the late arterial phase, and at an NI of 17 in the portal venous and equilibrium phases. In group B, the best results were obtained at an NI of 13 in the late arterial phase, and at an NI of 15 in the portal venous and equilibrium phases. CONCLUSION: Adjusting NI and iterative reconstruction algorithm based on body mass index can help improve image quality on contrast-enhanced liver CT scans, even at low radiation dose.

17.
Eur J Radiol ; 89: 47-53, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28267548

RESUMO

OBJECTIVE: To investigate the effect of the optimal monochromatic spectral computed tomography (CT) plus adaptive statistical iterative reconstruction on the improvement of the image quality of the superior mesenteric artery and vein. MATERIALS AND METHODS: The gemstone spectral CT angiographic data of 25 patients were reconstructed in the following three groups: 70KeV, the optimal monochromatic imaging, and the optimal monochromatic plus 40%iterative reconstruction mode. The CT value, image noises (IN), background CT value and noises, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR) and image scores of the vessels and surrounding tissues were analyzed. RESULTS: In the 70KeV, the optimal monochromatic and the optimal monochromatic images plus 40% iterative reconstruction group, the mean scores of image quality were 3.86, 4.24 and 4.25 for the superior mesenteric artery and 3.46, 3.78 and 3.81 for the superior mesenteric vein, respectively. The image quality scores for the optimal monochromatic and the optimal monochromatic plus 40% iterative reconstruction groups were significantly greater than for the 70KeV group (P<0.05). The vascular CT value, image noise, background noise, CNR and SNR were significantly (P<0.001) greater in the optimal monochromatic and the optimal monochromatic images plus 40% iterative reconstruction group than in the 70KeV group. The optimal monochromatic plus 40% iterative reconstruction group had significantly (P<0.05) lower image and background noise but higher CNR and SNR than the other two groups. CONCLUSION: The optimal monochromatic imaging combined with 40% iterative reconstruction using low-contrast agent dosage and low injection rate can significantly improve the image quality of the superior mesenteric artery and vein.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Artéria Mesentérica Superior/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Razão Sinal-Ruído
18.
Radiol Med ; 122(5): 327-336, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28197873

RESUMO

OBJECTIVE: The objective of our study was to compare the image quality and radiation dose of computed tomography angiography (CTA) of the kidney in patients with different body mass indexes using routine CT and the latest Gemstone Spectral Imaging (GSI) combination of different noise indexes (NI) with the adaptive statistical iterative reconstruction 2.0 algorithm (ASiR 2.0). METHODS: A total of 120 patients who had undergone a CTA of the kidney were divided into four groups (A, B, C and D), with 30 patients in each group. Group A underwent a routine CT examination, while groups B, C and D underwent GSI with different noise indexes. All images were restructured using ASiR 2.0. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of all images were calculated when the kidney CTA was completed. Each subjective image evaluation used a 5-point scoring method and was conducted by two independent radiologists. The CT dose index of volume (CTDIvol) and dose-length product (DLP) were recorded, and the mean value was calculated. The DLP was converted to the effective dose (ED). All data were compared with one-way ANOVA. RESULTS: The SNR, CNR and subjective image quality in group A were significantly lower than in groups B, C and D (P < 0.01). There were no significant differences in SNR, CNR and subjective image quality among groups B, C and D. The ED of group D decreased by 47.81 and 18.59% relative to groups A and B, respectively (P < 0.01). CONCLUSION: The latest GSI with different NI values can more effectively reduce the radiation dose than can the routine CT scan mode for a kidney CTA while still maintaining diagnostic image quality.


Assuntos
Artefatos , Angiografia por Tomografia Computadorizada , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Artéria Renal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal
19.
J Xray Sci Technol ; 25(1): 135-143, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27768006

RESUMO

OBJECTIVE: To investigate the effect of low-concentration contrast medium on spectral computed tomography (CT) image quality for portal venography CT. METHODS: 150 patients with suspected portal diseases were divided into three groups and had spectral CT examination using a GE Discovery CT 750 HD scanner. The patients in three groups were injected with different concentrations of iodine (350 mgI/mL, 315 mgI/mL and 280 mgI/mL) at an injection rate of 4.0-5.0 mL/s with 1.2 mL/kg (body weight) of contrast medium, respectively. During the portal vein imaging phase, 0.625 mm-slice-thickness monochromatic images and optimal monochromatic images were obtained. Optimal keV mono-energy was achieved using the optimal contrast-to-noise ratio (CNR) in the portal vein relative to the erector spinae muscle. Volume rendering and maximum intensity projection methods were applied to generate portal venography. The CT values and standard deviations were measured at the portal vein, the erector spinae muscle, and the abdomen fat, respectively. These values were used to calculate the signal-to-noise ratio (SNR); while CNR was calculated using CT values of the portal vein and erector spinae muscle. The overall imaging quality was evaluated on a five-point scale by two radiologists with at least five years' experience. Comparisons among the three groups were performed using One-Way ANOVA test. RESULTS: Monochromatic images at 50-53 keV demonstrated the best CNR for both the portal vein and erector spinae muscle. SNR and CNR of images with different contrast medium concentrations were similar (P > 0.05). The five-point scores were also similar (P > 0.05) for the three groups. The total iodine intake at 280 mgI/mL was 25.4% lower than that at 350 mgI/mL. CONCLUSIONS: Spectral CT with monochromatic images at 50-53 keV allows significant reduction in iodine load while improving portal vein signal intensity and maintaining image quality.


Assuntos
Meios de Contraste/administração & dosagem , Flebografia/métodos , Veia Porta/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/uso terapêutico , Feminino , Humanos , Hepatopatias/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Abdominal/métodos
20.
J Comput Assist Tomogr ; 41(2): 263-270, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27824666

RESUMO

OBJECTIVE: The objective of our study was to compare the image quality and radiation dose of computed tomography angiography (CTA) of the kidney in patients with different body mass indexes using routine CT and the latest gemstone spectral imaging (GSI) combination of different scanning protocols with the adaptive statistical iterative reconstruction 2.0 algorithm. METHODS: A total of 90 patients who had undergone a CTA of the kidney were divided into 3 groups (A, B, and C), with 30 patients in each group. Group A underwent a routine CT examination, whereas groups B and C underwent GSI with different scanning protocols. All images were restructured using the adaptive statistical iterative reconstruction 2.0. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of all images were calculated when the kidney CTA was completed. Each subjective image evaluation used a 5-point scoring method and was conducted by 2 independent radiologists. The CT dose index of volume and the dose-length product were recorded, and the mean value was calculated. The dose-length product was converted to the effective dose. All data were compared with a 1-way analysis of variance. RESULTS: The SNR, CNR, and subjective image quality in group A were significantly lower than those in groups B and C (P < 0.01). There were no significant differences in SNR, CNR, and subjective image quality between groups B and C. The effective dose of group C decreased by 46.05% and 15.03% relative to those of groups A and B, respectively (P < 0.01). CONCLUSIONS: The latest GSI with different scanning protocols can more effectively reduce the radiation dose than can the routine CT scan mode for a kidney CTA while still maintaining diagnostic image quality.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Rim/diagnóstico por imagem , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Índice de Massa Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA