Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 323
Filtrar
1.
EJNMMI Rep ; 8(1): 26, 2024 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-39183235

RESUMO

BACKGROUND: Transarterial radio-embolization (TARE) became a routine procedure for non-resectable liver tumor mainly hepatocellular carcinoma (HCC). Personalized dosimetry to the index lesion increased tumor response rate. However, there is no requirement to measure the precise activity injected during TARE. We measured 90Y-glass microspheres residue (90Y-Res) in the application system after TARE and assessed its potential impact on the tumor absorbed dose (AD) previously planned with 99mTc MAA SPECT/CT. METHODS: We measured 90Y-Res using PET/CT in all patients that underwent TARE using 90Y-glass-microspheres for non-resectable liver tumors over one year. RESULTS: 90Y-Res was measured in 34 patients (HCC n = 22) with 61 injections, 93.1 ± 94.6 MBq [2-437] that was 4.8 ± 3.5% [0.2-13.7] in comparison to the activity measured in the sealed TheraSphere™ vial (ρ = 0.697; p < 0.001). CONCLUSION: We reported an average of 5% 90Y-Res using PET/CT after TARE with the strongest association to the activity in the TheraSphere™ vial. Therefore, when a high 90Y-Res is suspected on the survey meter, a 90Y-PET/CT scan of 90Y-Res might be useful as a first step to estimate if the target lesion received the recommended AD, especially in HCC patients with borderline tumor dosimetry on the pre-treatment 99mTc-MAA SPECT/CT.

2.
J Nucl Med Technol ; 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39019573

RESUMO

A new 90Y SIR-Spheres delivery kit (SIROS D-vial and shield) has been introduced with a different physical form from the legacy V-Vial kit. Here, we establish the dose calibrator settings and exposure-rate-to-activity conversion factor to assay 90Y SIR-Spheres activity in the new SIROS kit. Methods: Eight D-vials with initial 90Y activities from 1.2 to 6.6 GBq within acrylic shields were assayed with dose calibrators and exposure-rate meters until activities decayed to approximately 0.1 GBq. The dose calibrator settings resulting in the lowest median activity errors and the best-fit slope of exposure rate versus activity were identified. Results: SIROS D-vial 90Y activity can be accurately and reliably estimated directly using setting 51 × 10 on both the CRC-15R and the CRC-55tR dose calibrators (errors within ±0.5%) and indirectly with an exposure-rate reading at 30 cm using conversion factor 0.664 ± 0.003 GBq/(mR/h) (R 2 = 0.985). Conclusion: Dose calibrator settings and exposure-rate-to-activity conversion factor for 90Y activity assays with new SIROS kit should be updated from legacy V-Vial parameters to avoid an approximately 10% underestimation.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38981950

RESUMO

BACKGROUND: Overall Survival (OS) and Progression-Free Survival (PFS) analyses are crucial metrics for evaluating the efficacy and impact of treatment. This study evaluated the role of clinical biomarkers and dosimetry parameters on survival outcomes of patients undergoing 90Y selective internal radiation therapy (SIRT). MATERIALS/METHODS: This preliminary and retrospective analysis included 17 patients with hepatocellular carcinoma (HCC) treated with 90Y SIRT. The patients underwent personalized treatment planning and voxel-wise dosimetry. After the procedure, the OS and PFS were evaluated. Three structures were delineated including tumoral liver (TL), normal perfused liver (NPL), and whole normal liver (WNL). 289 dose-volume constraints (DVCs) were extracted from dose-volume histograms of physical and biological effective dose (BED) maps calculated on 99mTc-MAA and 90Y SPECT/CT images. Subsequently, the DVCs and 16 clinical biomarkers were used as features for univariate and multivariate analysis. Cox proportional hazard ratio (HR) was employed for univariate analysis. HR and the concordance index (C-Index) were calculated for each feature. Using eight different strategies, a cross-combination of various models and feature selection (FS) methods was applied for multivariate analysis. The performance of each model was assessed using an averaged C-Index on a three-fold nested cross-validation framework. The Kaplan-Meier (KM) curve was employed for univariate and machine learning (ML) model performance assessment. RESULTS: The median OS was 11 months [95% CI: 8.5, 13.09], whereas the PFS was seven months [95% CI: 5.6, 10.98]. Univariate analysis demonstrated the presence of Ascites (HR: 9.2[1.8,47]) and the aim of SIRT (segmentectomy, lobectomy, palliative) (HR: 0.066 [0.0057, 0.78]), Aspartate aminotransferase (AST) level (HR:0.1 [0.012-0.86]), and MAA-Dose-V205(%)-TL (HR:8.5[1,72]) as predictors for OS. 90Y-derived parameters were associated with PFS but not with OS. MAA-Dose-V205(%)-WNL, MAA-BED-V400(%)-WNL with (HR:13 [1.5-120]) and 90Y-Dose-mean-TL, 90Y-D50-TL-Gy, 90Y-Dose-V205(%)-TL, 90Y-Dose- D50-TL-Gy, and 90Y-BED-V400(%)-TL (HR:15 [1.8-120]) were highly associated with PFS among dosimetry parameters. The highest C-index observed in multivariate analysis using ML was 0.94 ± 0.13 obtained from Variable Hunting-variable-importance (VH.VIMP) FS and Cox Proportional Hazard model predicting OS, using clinical features. However, the combination of VH. VIMP FS method with a Generalized Linear Model Network model predicting OS using Therapy strategy features outperformed the other models in terms of both C-index and stratification of KM curves (C-Index: 0.93 ± 0.14 and log-rank p-value of 0.023 for KM curve stratification). CONCLUSION: This preliminary study confirmed the role played by baseline clinical biomarkers and dosimetry parameters in predicting the treatment outcome, paving the way for the establishment of a dose-effect relationship. In addition, the feasibility of using ML along with these features was demonstrated as a helpful tool in the clinical management of patients, both prior to and following 90Y-SIRT.

4.
J Radioanal Nucl Chem ; 333: 841-845, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-39070724

RESUMO

A method for determining activity of 89Sr and 90Sr in a sample where 90Sr and 90Y are not in equilibrium is presented. The method consists of an experimental design and equations for accurately calculating activity of 89Sr and 90Sr based on 90Y ß particle counts and the total counts of ß particles emitted from 89Sr, 90Sr, and 90Y in a sample. The equations are derived based on chemical separation sequences, ß particle counting sequences, and the Bateman equation. The presented method allows simultaneously obtaining the activity of 89Sr and 90Sr in a non-equilibrated 90Sr/90Y system without the need of Cerenkov counting.

5.
J Nucl Med ; 65(8): 1224-1230, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38960710

RESUMO

Functional liver parenchyma can be damaged from treatment of liver malignancies with 90Y selective internal radiation therapy (SIRT). Evaluating functional parenchymal changes and developing an absorbed dose (AD)-toxicity model can assist the clinical management of patients receiving SIRT. We aimed to determine whether there is a correlation between 90Y PET AD voxel maps and spatial changes in the nontumoral liver (NTL) function derived from dynamic gadoxetic acid-enhanced MRI before and after SIRT. Methods: Dynamic gadoxetic acid-enhanced MRI scans were acquired before and after treatment for 11 patients undergoing 90Y SIRT. Gadoxetic acid uptake rate (k1) maps that directly quantify spatial liver parenchymal function were generated from MRI data. Voxel-based AD maps, derived from the 90Y PET/CT scans, were binned according to AD. Pre- and post-SIRT k1 maps were coregistered to the AD map. Absolute and percentage k1 loss in each bin was calculated as a measure of loss of liver function, and Spearman correlation coefficients between k1 loss and AD were evaluated for each patient. Average k1 loss over the patients was fit to a 3-parameter logistic function based on AD. Patients were further stratified into subgroups based on lesion type, baseline albumin-bilirubin scores and alanine transaminase levels, dose-volume effect, and number of SIRT treatments. Results: Significant positive correlations (ρ = 0.53-0.99, P < 0.001) between both absolute and percentage k1 loss and AD were observed in most patients (8/11). The average k1 loss over 9 patients also exhibited a significant strong correlation with AD (ρ ≥ 0.92, P < 0.001). The average percentage k1 loss of patients across AD bins was 28%, with a logistic function model demonstrating about a 25% k1 loss at about 100 Gy. Analysis between patient subgroups demonstrated that k1 loss was greater among patients with hepatocellular carcinoma, higher alanine transaminase levels, larger fractional volumes of NTL receiving an AD of 70 Gy or more, and sequential SIRT treatments. Conclusion: Novel application of multimodality imaging demonstrated a correlation between 90Y SIRT AD and spatial functional liver parenchymal degradation, indicating that a higher AD is associated with a larger loss of local hepatocyte function. With the developed response models, PET-derived AD maps can potentially be used prospectively to identify localized damage in liver and to enhance treatment strategies.


Assuntos
Fígado , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Radioisótopos de Ítrio , Humanos , Masculino , Feminino , Fígado/diagnóstico por imagem , Pessoa de Meia-Idade , Radioisótopos de Ítrio/uso terapêutico , Idoso , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/diagnóstico por imagem , Gadolínio DTPA , Testes de Função Hepática , Dosagem Radioterapêutica
6.
J Vasc Interv Radiol ; 2024 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-39009301

RESUMO

PURPOSE: To characterize the response and survival outcomes of yttrium-90 transarterial radioembolization (90Y-TARE) for unresectable, liver-dominant metastases from primary neoplasms other than colorectal carcinoma. MATERIALS AND METHODS: This study included 1474 patients enrolled in the RESiN registry who received resin 90Y-TARE as part of their oncologic management for unresectable primary or secondary liver tumors (NCT02685631). 33% (481/1474) were treated for liver metastases of non-colorectal origin (m-nonCRC), compared to 34% (497/1474) treated for colorectal liver metastases (mCRC) and 34% (496/1474) treated for hepatocellular carcinoma (HCC). Treatment response and cancer survival probabilities were computed and compared for each primary cancer type. The Kaplan-Meier method and log-rank test were used to compare survival outcomes. RESULTS: Radiological responses were observed in 12 unique cancer types, mostly heavily pre-treated malignancies refractory to multiple lines of systemic therapies. The overall use of resin 90Y-TARE in m-nonCRC resulted in better treatment outcomes in terms of duration of response, progression free survival, time to progression and overall survival (P = 0.04, P = 0.02, P = 0.01, P = 0.04). Analyses of cancer cell types revealed that metastatic neuroendocrine tumor, sarcoma, and ovarian, renal, prostate, and breast cancers were associated with superior treatment outcomes, whereas worse treatment outcomes were observed in metastatic lung, gastric, pancreatic and esophageal cancers. CONCLUSION: Real-world data demonstrate the use of resin 90Y-TARE in m-nonCRC refractory to standard chemotherapy. For some cell types, this expanded use achieved superior treatment outcomes relative to the reference standard of mCRC, suggesting the need for inquiry into broadened indications for 90Y-TARE.

7.
J Neuroendocrinol ; : e13425, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38937270

RESUMO

Peptide receptor radionuclide therapy (PRRT) is an established therapy for metastatic neuroendocrine neoplasms (NEN). The role of PRRT as a neoadjuvant treatment prior to surgery or other local therapies is uncertain. This scoping review aimed to define the landscape of evidence available detailing the utility of PRRT in the neo-adjuvant setting, including the clinical contexts, efficacy, and levels of evidence. A comprehensive literature search of PUBMED, SCOPUS, and EMBASE through to December 2022 was performed to identify reports of PRRT use as neoadjuvant therapy prior to local therapies. Observational studies and clinical trials were included. A total of 369 records were identified by the initial search, and 17 were included in the final analysis, comprising 179 patients treated with neoadjuvant PRRT. Publications included case reports, retrospective cohort series and a phase 2 trial. Definitions of unresectable disease were variable. Radioisotopes used included 177Lu (n = 142) and 90Y (n = 36), used separately (n = 178) or in combination (n = 1). A combination of PRRT with chemotherapy was also explored (n = 2). Toxicity data was reported in 11/17 studies. Survival analysis was reported in 3/17 studies. Surgical resection following PRRT was reported for both the primary tumor (n = 71) and metastases (n = 12). Resection rates could not be calculated as not all publications reported whether resection was completed. Published literature exploring the use of PRRT in the neoadjuvant setting is mostly limited to case reports and retrospective cohort studies. From these limited data there is reported to be a role of PRRT in neoadjuvant setting in the literature. However, the low quality of evidence precludes any definite conclusion on the grade of disease, site of primary, isotope used or use of concomitant chemotherapy that can benefit from this application. Further prospective studies will require collaboration between multiple centers to gain sufficient high-quality evidence.

8.
J Nucl Med Technol ; 52(2): 148-151, 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38839117

RESUMO

Our objective was to demonstrate primarily the safety and secondarily the efficacy of 90Y glass microspheres in selective internal radiation therapy (SIRT) for hepatocellular carcinoma (HCC) in a local Southeast Asian hospital. Methods: Eleven consecutive patients with small, unresectable, nonmetastatic HCC and referred for locoregional therapy with SIRT with a curative intention were followed up for 6 mo after the procedure by way of interviews, blood tests, and anatomic scans. Results: Although 5 patients had deranged liver function tests after the procedure, in only 1 patient did this constitute a grade 1 toxicity (in alkaline phosphatase) by the Common Terminology Criteria for Adverse Events. Half the patients showed a reduction in serum α-fetoprotein measurements, and 6 of 11 patients demonstrated an objective response (complete or partial) on imaging. Conclusion: SIRT with 90Y glass microspheres is a safe and efficacious locoregional therapy for unresectable HCC. There are similar articles published in the West; however, the patient population there comprises far fewer Asians and the underlying cause for HCC is different from that in the Asian population. Despite these differences, SIRT is an equally effective and safe option for such patients.


Assuntos
Carcinoma Hepatocelular , Vidro , Neoplasias Hepáticas , Microesferas , Radioisótopos de Ítrio , Humanos , Carcinoma Hepatocelular/radioterapia , Neoplasias Hepáticas/radioterapia , Radioisótopos de Ítrio/uso terapêutico , Masculino , Pessoa de Meia-Idade , Feminino , Idoso , Resultado do Tratamento , Segurança , Sudeste Asiático , População do Sudeste Asiático
9.
J Radioanal Nucl Chem ; 333(4): 2115-2120, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38737916

RESUMO

Liquid Scintillation Counting (LSC) gross alpha/beta screening is a valuable tool for providing rapid laboratory response for the analysis of human clinical urine samples during a large-scale radiation incident event. Verification of method performance, as required for clinical laboratory testing, is accomplished by the evaluation of routine, periodic measurements of radioactive spiked samples for quality control, performance testing, and accuracy checks. Radionuclide stability of alpha and beta emitters in urine for LSC analysis is an important consideration. The purpose of this work is to demonstrate optimal preparations and storage conditions of samples used for method verification.

10.
Appl Radiat Isot ; 209: 111338, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38714137

RESUMO

- Innovative methods were developed for direct 90Sr and 137Cs determination in soils by radiochemical separation and ß-counting. Studies focused on: (1) the suitability of PEG to remove silica by coating, (2) the decontamination effect of Cs from 40K, (3) iron elimination with Microthene-TOA column instead of oxalate complex, and (4) the effective separation of Y and Sr from Pb by a Microthene-TOA column which made the direct 90Sr determination possible in less time with just one resin-column. The methods were validated by analysing the IAEA reference materials, showing good agreement with the recommended values. The methods were used to determine 90Sr and 137Cs in 21 soil samples. The obtained 90Sr concentrations in the soils were in the range of 0.46-2.95 Bq kg-1, while 137Cs 1.24-35.5 Bq kg-1. The yields of yttrium and caesium were 73.4 ± 8.0% and 79.0 ± 9.1%, respectively.

11.
Br J Radiol ; 97(1159): 1255-1260, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38730551

RESUMO

OBJECTIVES: To compare the survival and objective response rate (ORR) of the patients receiving estimated tumour absorbed dose (ETAD) <140 Gy versus ETAD ≥140 Gy in patients with advanced chemorefractory colorectal carcinoma liver metastases (CRCLM) treated with yttrium-90 transarterial radioembolization (90Y TARE). METHODS: Between August 2016 and August 2023 adult patients with unresectable, chemorefractory CRCLM treated with 90Y TARE using glass particles, were retrospectively enrolled. Primary outcomes were overall survival (OS) and hepatic progression free survival (hPFS). Secondary outcome was ORR. RESULTS: A total of 40 patients with a mean age of 66.2 ± 7.8 years met the inclusion criteria. Mean ETAD for group 1 (ETAD <140 Gy) and group 2 (ETAD ≥140) were 131.2 ± 17.4 Gy versus 195 ± 45.6 Gy, respectively. The mean OS and hPFS for group 1 versus group 2 were 12 ± 10.3 months and 8.1 ± 9.3 months versus 9.3 ± 3 months and 7.1 ± 8.4 months, respectively and there were no significant differences (P = .181 and P = .366, respectively). ORR did not show significant difference between the groups (P = .432). CONCLUSION: In real-world practice, no significant difference was found in OS, hPFS, and ORR between patients who received ETAD <140 Gy versus ETAD ≥140 Gy in patients with CRCLM, in this series. ADVANCES IN KNOWLEDGE: This study demonstrated that increased tumour absorbed doses in radioembolization may not provide additional significant advantage for OS and hPFS for patients with CRCLM.


Assuntos
Neoplasias Colorretais , Embolização Terapêutica , Neoplasias Hepáticas , Dosagem Radioterapêutica , Radioisótopos de Ítrio , Humanos , Neoplasias Colorretais/patologia , Neoplasias Colorretais/radioterapia , Neoplasias Colorretais/mortalidade , Radioisótopos de Ítrio/uso terapêutico , Idoso , Masculino , Feminino , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/radioterapia , Estudos Retrospectivos , Embolização Terapêutica/métodos , Pessoa de Meia-Idade , Vidro , Resultado do Tratamento
12.
J Gastrointest Oncol ; 15(1): 356-367, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38482235

RESUMO

Background: 90Y radioembolization is an established treatment modality for hepatic malignancies. Successful radioembolization requires optimal dose delivery to tumors while minimizing dosages to parenchyma. Post-treatment positron emission tomography (PET)/computed tomography (CT) dosimetry is the established benchmark, whereas PET/magnetic resonance (MR) is an emerging modality. The goal of this study was to assess the intermodality agreement between PET/MR and PET/CT 90Y dosimetry. Methods: In this single-institution study, 18 patients (20 treatment sessions) with a primary or metastatic hepatic malignancy underwent both PET/MR and PET/CT after 90Y radioembolization. Patients were randomized to undergo one modality first, followed by the other. The region of interest was delineated using MR images and tumor and liver dosimetry was calculated. Intermodality agreement was assessed using the Bland-Altman method. A generalized linear model was used to assess the effect of baseline variables on intermodality dose differences. Results: PET/MR underestimated tumor and liver absorbed doses when compared to PET/CT by -3.7% (P=0.042) and -5.8% (P=0.029), respectively. A coverage probability plot demonstrated that 80% and 90% of tumor dose measurements fell within intermodality differences of 11% and 18%, respectively. PET/MR underestimated tumor dose at both low (<1 GBq) and high (>3 GBq) injected activity levels (P<0.001) by -22.3 [standard deviation (SD) =13.5] and -24.3 (SD =18.7), respectively. Conclusions: Although PET/MR significantly underestimated the absorbed dose when compared to PET/CT, the intermodality agreement was high and the degree of underestimation was better than previously reported. Intermodality differences were more pronounced at low and high injected doses. Additional studies are required to assess the clinical implications of these findings.

13.
Nucl Med Mol Imaging ; 58(2): 86-91, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38510819

RESUMO

Transarterial radioembolization using yttrium-90 (90Y) therapy has become a standard modality of treatment for primary and metastatic liver malignancies due to its high efficacy rate and relatively low risk of adverse effects compared to other forms of locoregional and systemic therapies. Non-target distribution of radio embolic beads and adjacent structure radiation are the two most common adverse effects. However, these are rarely encountered due to thorough imaging and mapping studies prior to 90Y therapy. We present the case of a 66-year-old male who developed a radiation-induced gastric ulcer following 90Y therapy with negative pre-procedural imaging and mapping who was retrospectively found to have an accessory artery from the left hepatic artery to the gastric antrum.

14.
J Nucl Med ; 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38388514

RESUMO

90Y-microsphere radioembolization has become a well-established treatment option for liver malignancies and is one of the first U.S. Food and Drug Administration-approved unsealed radionuclide brachytherapy devices to incorporate dosimetry-based treatment planning. Several different mathematical models are used to calculate the patient-specific prescribed activity of 90Y, namely, body surface area (SIR-Spheres only), MIRD single compartment, and MIRD dual compartment (partition). Under the auspices of the MIRDsoft initiative to develop community dosimetry software and tools, the body surface area, MIRD single-compartment, MIRD dual-compartment, and MIRD multicompartment models have been integrated into a MIRDy90 software worksheet. The worksheet was built in MS Excel to estimate and compare prescribed activities calculated via these respective models. The MIRDy90 software was validated against available tools for calculating 90Y prescribed activity. The results of MIRDy90 calculations were compared with those obtained from vendor and community-developed tools, and the calculations agreed well. The MIRDy90 worksheet was developed to provide a vetted tool to better evaluate patient-specific prescribed activities calculated via different models, as well as model influences with respect to varying input parameters. MIRDy90 allows users to interact and visualize the results of various parameter combinations. Variables, equations, and calculations are described in the MIRDy90 documentation and articulated in the MIRDy90 worksheet. The worksheet is distributed as a free tool to build expertise within the medical physics community and create a vetted standard for model and variable management.

15.
Clin Colon Rectal Surg ; 37(2): 114-121, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38327731

RESUMO

Future options for the management of stage IV colorectal cancer are primarily focused on personalized and directed therapies. Interventions include precision cancer medicine, utilizing nanocarrier platforms for directed chemotherapy, palliative pressurized intraperitoneal aerosol chemotherapy (PIPAC), adjunctive oncolytic virotherapy, and radioembolization techniques. Comprehensive genetic profiling provides specific tumor-directed therapy based on individual genetics. Biomimetic magnetic nanoparticles as chemotherapy delivery systems may reduce systemic side effects of traditional chemotherapy by targeting tumor cells and sparing healthy cells. PIPAC is a newly emerging option for patients with peritoneal metastasis from colorectal cancer and is now being used internationally, showing promising results as a palliative therapy for colorectal cancer. Oncolytic virotherapy is another emerging potential treatment option, especially when combined with standard chemotherapy and/or radiation, as well as immunotherapy. And finally, radioembolization with yttrium-90 ( 90 Y) microspheres has shown some success in treating patients with unresectable liver metastasis from colorectal cancer via selective arterial injection.

16.
Curr Radiopharm ; 17(3): 276-284, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38288829

RESUMO

INTRODUCTION: The most important toxicity of transarterial radioembolization therapy applied in liver malignancies is radiation pneumonitis and fibrosis due to hepatopulmonary shunt of Yttrium-90 (90Y) microspheres. Currently, Technetium-99m macroaggregated albumin (99mTc-MAA) scintigraphic images are used to estimate lung shunt fraction (LSF) before treatment. The aim of this study was to create a phantom to calculate exact LFS rates according to 99mTc activities in the phantom and to compare these rates with LSF values calculated from scintigraphic images. MATERIALS AND METHODS: A 3D-printed lung and liver phantom containing two liver tumors was developed from Polylactic Acid (PLA) material, which is similar to the normal-sized human body in terms of texture and density. Actual %LSFs were calculated by filling phantoms and tumors with 99mTc radionuclide. After the phantoms were placed in the water tank made of plexiglass material, planar, SPECT, and SPECT/CT images were obtained. The actual LSF ratio calculated from the activity amounts filled into the phantom was used for the verification of the quantification of scintigraphic images and the results obtained by the Simplicity90YTM method. RESULTS: In our experimental model, LSFs calculated from 99mTc activities filled into the lungs, normal liver, small tumor, and large tumor were found to be 0%, 6.2%, 10.8%, and 16.9%. According to these actual LSF values, LSF values were calculated from planar, SPECT/CT (without attenuation correction), and SPECT/CT (with both attenuation and scatter correction) scintigraphic images of the phantom. In each scintigraphy, doses were calculated for lung, small tumor, large tumor, normal liver, and Simplicity90YTM. The doses calculated from planar and SPECT/CT (NoAC+NoSC) images were found to be higher than the actual doses. The doses calculated from SPECT/CT (with AC+with SC) images and Simplicity90YTM were found to be closer to the real dose values. CONCLUSION: LSF is critical in dosimetry calculations of 90Y microsphere therapy. The newly introduced hepatopulmonary shunt phantom in this study is suitable for LSF verification for all models/brands of SPECT and SPECT/CT devices.


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas , Imagens de Fantasmas , Compostos Radiofarmacêuticos , Agregado de Albumina Marcado com Tecnécio Tc 99m , Radioisótopos de Ítrio , Humanos , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/diagnóstico por imagem , Embolização Terapêutica/métodos , Compostos Radiofarmacêuticos/uso terapêutico , Radioisótopos de Ítrio/uso terapêutico , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Microesferas , Pulmão/diagnóstico por imagem , Pulmão/efeitos da radiação , Impressão Tridimensional , Fígado/diagnóstico por imagem
17.
Cancer Biother Radiopharm ; 39(1): 82-91, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38265675

RESUMO

Background: Selective internal radiation therapy (SIRT) using a suitable ß--emitting radionuclide is a promising treatment modality for unresectable liver carcinoma. Yttrium-90 (90Y) [T1/2 = 64.2 h, Eß(max) = 2.28 MeV, no detectable γ-photon] is the most preferred radioisotope for SIRT owing to its favorable decay characteristics. Objective: The present study describes indigenous development and evaluation of intrinsically radiolabeled [90Y]yttria alumino silicate ([90Y]YAS) glass microsphere, a formulation biosimilar to "TheraSphere" (commercially available, U.S. FDA-approved formulation), for SIRT of unresectable liver carcinoma in human patients. Methods: YAS glass microspheres of composition 40Y2O3-20Al2O3-40SiO2 (w/w) and diameter ranging between 20 and 36 µm were synthesized with almost 100% conversion efficiency and >99% sphericity. Intrinsically labeled [90Y]YAS glass microspheres were produced by thermal neutron irradiation of cold YAS glass microspheres in a research reactor. Subsequent to in vitro evaluations and in vivo studies in healthy Wistar rats, customized doses of [90Y]YAS glass microspheres were administered in human patients. Results: [90Y]YAS glass microspheres were produced with 137.7 ± 8.6 MBq/mg YAS glass (∼6800 Bq per microsphere) specific activity and 99.94% ± 0.02% radionuclidic purity at the end of irradiation. The formulation exhibited excellent in vitro stability in human serum and showed >97% retention in the liver up to 7 d post-administration when biodistribution studies were carried out in healthy Wistar rats. Yttrium-90 positron emission tomography scans recorded at different time points post-administration of customized dose of [90Y]YAS glass microspheres in human patients showed near-quantitative retention of the formulation in the injected lobe. Conclusions: The study confirmed the suitability of indigenously prepared [90Y]YAS glass microspheres for clinical use in the treatment of unresectable hepatocellular carcinoma.


Assuntos
Medicamentos Biossimilares , Carcinoma Hepatocelular , Embolização Terapêutica , Neoplasias Hepáticas , Ítrio , Ratos , Animais , Humanos , Microesferas , Ratos Wistar , Distribuição Tecidual , Análise Custo-Benefício , Neoplasias Hepáticas/patologia , Radioisótopos de Ítrio/uso terapêutico , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/tratamento farmacológico , Compostos Radiofarmacêuticos/uso terapêutico
18.
J Nucl Med ; 65(2): 264-269, 2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-38212068

RESUMO

Interim analysis of the DOSISPHERE-01 study demonstrated a strong improvement in response and overall survival (OS) on using 90Y-loaded glass microspheres with personalized dosimetry compared with standard dosimetry in patients with nonoperable locally advanced hepatocellular carcinoma. This report sought to provide a long-term analysis of OS. Methods: In this phase II study (ClinicalTrials.gov identifier NCT02582034), treatment was randomly assigned (1:1) with the goal to deliver either at least 205 Gy (if possible >250-300 Gy) to the index lesion in the personalized dosimetry approach (PDA) or 120 ± 20 Gy to the treated volume in the standard dosimetry approach (SDA). The 3-mo response of the index lesion was the primary endpoint, with OS being one of the secondary endpoints. This report is a post hoc long-term analysis of OS. Results: Overall, 60 hepatocellular carcinoma patients with at least 1 lesion larger than 7 cm and more than 30% of hepatic reserve were randomized (intent-to-treat population: PDA, n = 31; SDA, n = 29), with 56 actually treated (modified intent-to-treat population: n = 28 in each arm). The median follow-up for long-term analysis was 65.8 mo (range, 2.1-73.1 mo). Median OS was 24.8 mo and 10.7 mo (hazard ratio [HR], 0.51; 95% CI, 0.29-0.9; P = 0.02) for PDA and SDA, respectively, in the modified intent-to-treat population. Median OS was 22.9 mo for patients with a tumor dose of at least 205 Gy, versus 10.3 mo for those with a tumor dose of less than 205 Gy (HR, 0.42; 95% CI, 0.22-0.81; P = 0.0095), and was 22.9 mo for patients with a perfused liver dose of 150 Gy or higher, versus 10.3 mo for those with a perfused liver dose of less than 150 Gy (HR, 0.42; 95% CI, 0.23-0.75; P = 0.0033). Lastly, median OS was not reached in patients who were secondarily resected (n = 11, 10 in the PDA group and 1 in the SDA group), versus 10.8 mo in those without secondary resection (n = 45) (HR, 0.17; 95% CI, 0.065-0.43; P = 0.0002). Only resected patients displayed favorable long-term OS rates, meaning an OS of more than 50% at 5 y. Conclusion: After longer follow-up, personalized dosimetry sustained a meaningful improvement in OS, which was dramatically improved for patients who were accurately downstaged toward resection, including most portal vein thrombosis patients.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Trombose Venosa , Humanos , Carcinoma Hepatocelular/tratamento farmacológico , Neoplasias Hepáticas/patologia , Radiometria , Trombose Venosa/complicações , Radioisótopos de Ítrio/uso terapêutico , Microesferas
19.
Theranostics ; 14(1): 133-142, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38164147

RESUMO

Rationale: Peptide receptor radionuclide therapy (PRRT) for the treatment of neuroendocrine tumors (NETs) has been explored for more than two decades, but there are only limited data on the treatment of NETs of unknown primary site (CUP-NETs). This study aimed to analyze the long-term outcome, efficacy, and safety of PRRT in patients with CUP-NETs. Methods: Patients with pathologically confirmed metastatic CUP-NET who received lutetium-177 (177Lu) and/or yttrium-90 (90Y) labeled somatostatin analogs between March 2001 and March 2019 were retrospectively reviewed; those patients were referred as cCUP-NETs (clinical CUP-NETs). Eighty-one patients had unknown primary tumors even after [68Ga]Ga-SSTR and [18F]FDG PET/CT and were classified as pCUP-NETs (PET CUP-NETs). Treatment response was assessed according to RECIST 1.1 and PERCIST. Progression-free survival (PFS) and overall survival (OS) were estimated using Kaplan-Meier analysis, and adverse events were graded according to the National Cancer Institute Common Terminology Criteria for Adverse Events (CTCAE), version 5.0. Results: A total of 575 PRRT cycles were administered to 156 patients (76 men and 80 women) evaluable for analysis: these patients were monitored for a median period of 92.3 mo (range, 4.0-169.1 mo). The disease control rate was 41.4% (43.4%) by RECIST and 40.2% (40.8%) by PERCIST in cCUP-NENs (pCUP-NETs). The objective response rate (ORR) with PRRT was 29.4% and 32.2% in cCUP-NENs and pCUP-NETs, respectively. The median PFS and OS for the entire cohort were 17.4 mo (95% confidence interval [95% CI], 11.4-23.4) and 67.4 mo (95% CI, 47.2-87.2) for all patients, respectively. The median OS for G3 tumors was significantly lower (15 mo) than for patients with G1 NET (85.5 mo), G2 (71.7 mo), and for patients with unknown grade (63.3 mo) NETs (P = 0.186, HR: 10.6, 95% CI: 3.87, 28.97, P = 0.09). PRRT was well tolerated by all patients. During treatment and long-term follow-up, CTCAE grade 3 and grade 4 thrombocytopenia and leukocytopenia were observed in only 3 patients (1.9%); there was no evidence of renal or hepatic toxicity. Conclusion: In a large cohort of patients with advanced CUP-NETs treated with PRRT in a real-world scenario and followed up to 14 years after the commencement, PRRT has demonstrated favorable and clinically significant efficacy and survival with minimal and acceptable side effects. Our results indicate that PRRT is a well-tolerated and effective treatment option for patients with metastatic CUP-NETs expressing somatostatin receptors.


Assuntos
Neoplasias Primárias Desconhecidas , Tumores Neuroendócrinos , Compostos Organometálicos , Masculino , Humanos , Feminino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias Primárias Desconhecidas/radioterapia , Neoplasias Primárias Desconhecidas/induzido quimicamente , Neoplasias Primárias Desconhecidas/tratamento farmacológico , Estudos Retrospectivos , Tumores Neuroendócrinos/radioterapia , Radioisótopos/uso terapêutico , Receptores de Somatostatina , Octreotida , Compostos Organometálicos/uso terapêutico
20.
Theranostics ; 14(2): 451-459, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38169589

RESUMO

Rationale: The kidneys are commonly considered as the potential dose-limiting organ for peptide receptor radionuclide therapy (PRRT), making the risk of nephrotoxicity a primary concern. This retrospective analysis with prospective documentation and long-term follow-up aims to assess the risk of nephrotoxicity after PRRT in a large cohort of patients with neuroendocrine neoplasms (NENs) treated at our institution over the past 18 years. Methods: A total of 1361 NEN patients treated with 1-10 cycles of 177Lu-DOTA-TOC/-NOC/-TATE, 90Y-DOTA-TOC/-NOC/-TATE, DUO-PRRT (sequential administration of 90Y- and 177Lu-), or TANDEM-PRRT (combination of 90Y- and 177Lu- on the same day concomitantly) were included in this analysis. All parameters were prospectively documented in a structured database comprising over 250 items per patient and retrospectively analyzed. Kidney function, including serum creatinine, blood urea nitrogen, cGFR, and electrolytes, was evaluated before each PRRT cycle and during follow-up. Restaging was regularly performed at 6-month intervals until death. Treatment-related adverse events were graded according to the Common Terminology Criteria for Adverse Events (CTCAE v.5.0). Results: Between 2000 and 2018, a total of 5409 cycles of PRRT were administered to 1361 NEN patients. Follow-up after complete treatment was available for 1281 patients receiving 4709 cycles of PRRT, with a median follow-up time of 69.2 months (interquartile range, 32.8-110.5 months) and a maximum follow-up time of 175 months. Baseline creatinine levels were normal in 1039/1281 (81.1%) subjects, while grade 1 (G1) renal insufficiency was present in 221/1281 (17.3%) prior to PRRT. G2 was present in 19/1281 (1.5%), and G3 in 2/1281 (0.2%). After treatment, the proportion of G3/G4 grade patients only increased from 0.2% to 0.7%. Mean creatinine levels increased from a baseline of 0.90 ± 0.30 to 1.01 ± 0.57 mg/L (80.0 ± 26.7 to 89.4 ± 50.8 µmol/L) after treatment. In our main analysis cohort of 1244 patients (4576 cycles), 200 patients experienced an increase in CTCAE creatinine grade. Age, number of treatment cycles, type of radionuclides, and length of follow-up time were the main factors affecting CTCAE creatinine grading after treatment. When comparing the subgroups treated with different radionuclides, the risk of nephrotoxicity after 90Y treatment alone and the 90Y/177Lu combination group was higher than after 177Lu treatment alone. In the 90Y treatment subgroup, the two significant risk factors for an increased CTCAE creatinine grade were identified to be age (≥60) and a long follow-up time. Conclusions: This retrospective analysis with prospective documentation in a large cohort of 1281 NEN patients receiving 4709 cycles of PRRT co-administered with renal protection, treated through the individualized approach at a single institution over 18 years, did not reveal any evidence of long-term PRRT-related renal toxicity. The results of our study suggest that with the use of proper renal protection, nephrotoxicity due to PRRT is more likely a myth than a reality.


Assuntos
Tumores Neuroendócrinos , Compostos Organometálicos , Insuficiência Renal , Humanos , Estudos Retrospectivos , Creatinina , Estudos Prospectivos , Octreotida/efeitos adversos , Insuficiência Renal/induzido quimicamente , Compostos Organometálicos/efeitos adversos , Radioisótopos/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA