Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 840
Filtrar
1.
Ophthalmologie ; 2024 Oct 01.
Artigo em Alemão | MEDLINE | ID: mdl-39352514

RESUMO

Fuchs endothelial corneal dystrophy (FECD) is a genetic and age-associated corneal disease characterized by an accelerated loss of corneal endothelial cells and an increased subendothelial deposition of extracellular matrix (ECM). Clinically, advanced disease leads to corneal edema with subsequent reduction in visual acuity. In the majority of patients with advanced FECD, a fibrillar layer (FL) appears on the posterior corneal surface. This FL is mostly localized in the inferotemporal corneal quadrant, marks areas with significantly reduced endothelial cell density and increased corneal thickness in the sense of edema and can be visualized and measured using Scheimpflug backscatter analysis due to increased backscatter. FECD is currently the most common indication for corneal transplantation worldwide, usually in the form of Descemet membrane endothelial keratoplasty (DMEK). New treatment approaches include variations of DMEK surgery such as hemi- or quarter DMEK with individualized and smaller grafts or Descemet membrane stripping only (DSO). In the future, clinical imaging of the FL as a particularly affected endothelial area could be important for FECD progression assessment and planning of surgical interventions. This article provides an overview of the current state of research on the clinical aspects, pathogenesis, fibrillar layer and individualized treatment of FECD.

2.
Ann Med Surg (Lond) ; 86(10): 6198-6202, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39359825

RESUMO

Introduction and importance: Renal cell carcinoma (RCC) is the most common primary renal malignancy in patients between the ages of 50 and 70. A rare described variant of RCC is transcription factor for immunoglobulin heavy-chain enhancer 3 (TFE3) rearranged RCC. Osseous metaplasia, which refers to the occurrence of normal bone tissue in soft tissue, has been observed in all subtypes of renal cell carcinoma (RCC); however, only three previous case reports have documented the occurrence of osseous metaplasia in TFE3-rearranged RCC. Case presentation: We present a case of a 65-year-old woman presenting with an incidentally discovered calcified Bi-lobed renal mass detected on bone densitometry composed of a calcified thick-walled cyst measuring 7×6.5×6.5 cm showing intraluminal densities and heterogeneous content, and a lobulated partially exophytic renal mass measuring 4.5×5.5×4.5 cm. The patient underwent robotic-assisted radical nephrectomy confirming the diagnosis of RCC with osseous metaplasia extending into the pelvic calyces and renal sinus fat implicating a pathological stage of T3a. Clinical discussion: TFE3-rearranged RCCs represent a rare sub-classification in adult RCCs. It may be associated with unfavorable prognosis and aggressive patterns of disease in the presence of osseous metaplasia. Conclusion: This is the first case in the literature of TFE3-rearranged RCC with osseous metaplasia on bone mass densitometry scan and the fourth case of TFE3-rearranged RCC with osseous metaplasia. The patient is to be treated as a high-risk patient and to be monitored closely for recurrence of malignancy, as indicated in the EAU guidelines.

3.
Surv Ophthalmol ; 2024 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-39326741

RESUMO

Corneal densitometry (CD) is one of the biological properties of the cornea that can visualize the morphology of the cornea and determine the degree of corneal transparency. At present, it is an emerging metric that has shown promise in various clinical diagnosis and evaluation of eye diseases and surgeries. We introduce the different methodologies used to measure CD. Furthermore, we systematically categorize the diagnostic value of CD into high, medium, and low levels based on its clinical significance. By analyzing a wide range of conditions, including keratoconus, postrefractive surgery changes, and other corneal pathologies, we assess the utility of CD in each context. We also discuss the potential implications of these classifications for disease monitoring and prognosis evaluation. Our review underscores the importance of integrating CD assessments into routine clinical practice to enhance the accuracy and effectiveness of diagnostic processes for cornea-related disorders.

4.
Int Ophthalmol ; 44(1): 392, 2024 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-39320570

RESUMO

PURPOSE: To evaluate and compare the repeatability of corneal densitometry (CD) measurements obtained using both an anterior-segment optical coherence tomography (AS-OCT) device and a Scheimpflug camera system, while also assessing the level of agreement. The study also sought to investigate the correlation of CD with age, gender, and central corneal thickness (CCT) in normal eyes. METHODS: CD measurements were obtained using the Casia 2 and the Pentacam AXL Wave. Data were collected on Total Corneal Densitometry and 4 concentric corneal annular areas, these are referred to as zone 1, denoting the central area, through to zone 4, designating the outermost peripheral region. Repeatability was assessed using intra-session test-retest variability, coefficient of variation (CoV), and intraclass correlation coefficient (ICC). The agreement was evaluated using Bland-Altman plots. Correlation analysis was performed between CD, age, gender, and CCT. RESULTS: The study included 96 healthy volunteers. The Casia 2 demonstrated high repeatability with ICC values exceeding 0.9 in all the corneal zones and lower CoV values compared to the Pentacam AXL Wave (ranging from 1.07% to 2.25% for Casia 2 and from 1.91% to 6.89% for Pentacam).95% LoA were within ± 2 standard deviation from the average mean except from zone 1 (± 2.42).However, the measurements showed a consistent bias among all the corneal zones. CD values were positively correlated with age, except for zone 1 with the Pentacam (p = 0.083). CONCLUSIONS: The findings suggest that the Casia 2 can be a reliable tool for assessing corneal transparency in healthy individuals, however its measurements are not interchangeable with those provided by the Pentacam. The AS-OCT device may be more sensitive in detecting subtle age-related changes in CD within the central zone.


Assuntos
Córnea , Densitometria , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Masculino , Feminino , Córnea/diagnóstico por imagem , Densitometria/métodos , Adulto , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem , Segmento Anterior do Olho/diagnóstico por imagem , Idoso , Voluntários Saudáveis , Fotografação/métodos , Estudos Prospectivos , Adolescente
5.
Sensors (Basel) ; 24(17)2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39275686

RESUMO

Bone mineral density (BMD) varies with aging and both systemic and local diseases; however, such evidence is lacking in feline medicine. This may be due to the need for general anesthesia in cats for direct BMD measurements using dual-energy X-ray absorptiometry (DXA) or quantitative computed tomography (QCT). In this study, computed digital absorptiometry (CDA), an indirect relative BMD-measuring method, was optimized to select an X-ray tube setting for the quantitative assessment of the feline knee joint. The knee joints of nine cats were radiographically imaged and processed using the CDA method with an aluminum density standard and five X-ray tube settings (from 50 to 80 kV; between 1.2 and 12 mAs). The reference attenuation of the X-ray beam for ten steps (S1-S10) of the density standard was recorded in Hounsfield units (HU), compared between X-ray tube settings, and used to determine the ranges of relative density applied for radiograph decomposition. The relative density decreased (p < 0.0001) with an increase in kV and dispersed with an increase in mAs. Then, the percentage of color pixels (%color pixels), representing ranges of relative density, was compared among S1-S10 and used for the recognition of background artifacts. The %color pixels was the highest for low steps and the lowest for high steps (p < 0.0001), regardless of X-ray tube settings. The X-ray tube setting was considered the most beneficial when it effectively covered the lowest possible HU ranges without inducing background artifacts. In conclusion, for further clinical application of the CDA method for quantitative research on knee joint OA in cats, 60 kV and 1.2 mAs settings are recommended.


Assuntos
Absorciometria de Fóton , Densidade Óssea , Articulação do Joelho , Animais , Gatos , Densidade Óssea/fisiologia , Absorciometria de Fóton/métodos , Articulação do Joelho/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Raios X
6.
Artigo em Inglês | MEDLINE | ID: mdl-39223341

RESUMO

Asphyxia as a cause of death poses a diagnostic challenge in forensic medicine due to both the diversity of underlying mechanisms, and lack of specific markers. Acute emphysema or acute alveolar dilation have long been debated as potential findings in these asphyxia cases. To further explore the supplementary findings in our forensic asphyxia cases, this study applied lung densitometry to pulmonary postmortem computed tomography (PMCT) data. Twenty asphyxia cases (including hanging (n = 9), manual strangulation (n = 4), ligature strangulation (n = 1), smothering (n = 3), and choking (n = 3)) and 21 matched control cases were analysed using lung densitometry parameters - specifically quantification of low attenuation areas (LAA) and the 15th percentile point of lung density (Perc15). Our data revealed statistically significantly higher lung % volume falling within LAA at -950HU (p = 0.04) and - 910HU (p = 0.043) in the asphyxia cases compared to matched controls. The Perc15 values observed were trending towards a lower attenuation corresponding to a lower density in the asphyxia group, although this result was not statistically significant (p = 0.13). A subgroup analysis highlighted potential differences within the asphyxia categories, notably, higher Perc15 values were observed in the choking cases. In conclusion the results from the study support the existing evidence of low pulmonary density as a potential finding in asphyxia cases and demonstrate the potential of applying lung densitometry on pulmonary postmortem computed tomography data.

7.
Struct Heart ; 8(5): 100346, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39290676

RESUMO

Background: JenaValve's Trilogy transcatheter heart valve (THV) (JenaValve Inc, Irvine, CA) is the only conformité européenne-marked THV system for the treatment of aortic regurgitation (AR) or aortic stenosis (AS). However, its efficacy has not been quantitatively investigated pre- and post-implantation using video-densitometric analysis. Methods: Using the CAAS-A-Valve 2.1.2 software (Pie Medical Imaging, Maastricht, the Netherlands), an independent core lab retrospectively analyzed the aortograms of 88 consecutive patients (68 severe AR; 20 severe AS) receiving the JenaValve THV in three European centers. Video-densitometric AR was categorized by the regurgitant fraction (RF) as none/trace AR (RF ≤ 6%), mild (6% < RF ≤ 17%), and moderate/severe AR (RF > 17%). Results: Pre- and post-THV aortograms were analyzable in 17 (22.4%) and 47 (54.0%) patients, respectively. The main reasons preventing analysis were the descending aorta overlap of the outflow tract (30%) and insufficient frame count (6%). The median RF pre- and post-THV implant was 31.0% (interquartile range 21.5-38.6%) and 5.0% (interquartile range 1.0-7.0%, p < 0.001), respectively. The post-THV incidence of none/trace AR was 72.3%, and of mild AR, 27.7%, with no cases of moderate/severe AR. Video-densitometry analysis of the 12 AR cases with paired pre- and post-THV showed a reduction in the RF of 21.8% ± 8.1%. Conclusions: Quantitative aortography confirms the low rates of AR and the large reduction in RF following the implantation of Jenavalve's Trilogy THV, irrespective of implant indication. However, these limited data need corroborating in prospective studies using standardized acquisition protocols.

8.
Artigo em Inglês | MEDLINE | ID: mdl-39285066

RESUMO

PURPOSE: Neo-sinus flow stasis has ben correlated with transcatheter heart valve (THV) thrombosis severity and occurrence. Standard benchtop flow field quantification techniques require optical access or modified prosthesis models that may not reflect the true nature of the original valve. En face and fluoroscopic videodensitometry enable visualization of washout in regions otherwise unviewable. METHODS: This study compares two in vitro methods of assessing flow stasis in scenarios with insufficient optical access for traditional techniques such as particle image velocimetry (PIV). A series of seven paired experiments were conducted using a previously described laser-enhanced video densitometry (LEVD) and fluoroscopic video densitometry (FVD). Both sets of experiments were analyzed to calculate washout time as a measure of flow stasis. A novel flow stasis measure termed contrast attenuation ratio (CAR) is proposed as a viable single measure of flow stasis obtainable from only a small number of cardiac cycles of in vitro or in vivo fluoroscopic data. Retrospective fluoroscopic datasets (n = 72) were analyzed to assess the feasibility of obtaining this metric from routine clinical practice and its ability to stratify results. RESULTS: Neo-sinus flow stasis calculated from in vitro fluoroscopy was well correlated with LEVD (r2 = 0.77, p = 0.009). The newly proposed CAR metric showed good agreement with the commonly used "washout time" measure of flow stasis (r2 = 0.91, p < 0.001) while allowing for assessment with incomplete or truncated data. As a proof of concept, CAR was measured in 72 consecutive retrospective fluoroscopic datasets. CAR averaged 10.6 ± 4.6% with a range of 1.5-20.3% in these patients. CONCLUSIONS: This study demonstrates two in vitro methods that can be used to assess relative flow stasis in otherwise optically inaccessible regions surrounding cardiac or vascular implants. In addition, the fluoroscopic benchtop technique was used to validate a metric that allows for extension to routine clinical fluoroscopy. This contrast attenuation ratio (CAR) metric was found to be both accurate and clinically obtainable, and potentially offers a new method for valve thrombosis risk stratification.

9.
J Biomed Opt ; 29(Suppl 3): S33306, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39247899

RESUMO

Significance: The arterial input function (AIF) plays a crucial role in correcting the time-dependent concentration of the contrast agent within the arterial system, accounting for variations in agent injection parameters (speed, timing, etc.) across patients. Understanding the significance of the AIF can enhance the accuracy of tissue vascular perfusion assessment through indocyanine green-based dynamic contrast-enhanced fluorescence imaging (DCE-FI). Aim: We evaluate the impact of the AIF on perfusion assessment through DCE-FI. Approach: A total of 144 AIFs were acquired from 110 patients using a pulse dye densitometer. Simulation and patient intraoperative imaging were conducted to validate the significance of AIF for perfusion assessment based on kinetic parameters extracted from fluorescence images before and after AIF correction. The kinetic model accuracy was evaluated by assessing the variability of kinetic parameters using individual AIF versus population-based AIF. Results: Individual AIF can reduce the variability in kinetic parameters, and population-based AIF can potentially replace individual AIF for estimating wash-out rate ( k ep ), maximum intensity ( I max ), ingress slope with lower differences compared with those in estimating blood flow, volume transfer constant ( K trans ), and time to peak. Conclusions: Individual AIF can provide the most accurate perfusion assessment compared with assessment without AIF or based on population-based AIF correction.


Assuntos
Verde de Indocianina , Imagem Óptica , Humanos , Imagem Óptica/métodos , Verde de Indocianina/química , Verde de Indocianina/farmacocinética , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Meios de Contraste/química , Adulto , Artérias/diagnóstico por imagem , Imagem de Perfusão/métodos , Simulação por Computador
10.
J Public Health Dent ; 2024 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-39243208

RESUMO

OBJECTIVES: To assess the relationships between longitudinal fluoride intakes and bone densitometry outcomes in young adults. METHODS: Data were analyzed from the Iowa Fluoride Study and Iowa Bone Development Study, which followed 1,882 infants from birth in 1992. Daily fluoride intakes were assessed using detailed questionnaires sent every 1.5-6 months, and multi-row detector computed tomography (MDCT) scans of distal tibia were obtained from 330 participants aged 23 years. Sex-specific bivariate and multivariable associations with MDCT outcomes were examined using linear regression. Because of the multiple statistical analyses being conducted, p-values < 0.01 were considered statistically significant. RESULTS: In fully adjusted analyses, no statistically significant (p < 0.01) or suggestive (0.01 < p < 0.05) associations were found between period-specific or cumulative fluoride intake and bone measures for either sex, although there were suggestive positive relationships in unadjusted analyses. CONCLUSIONS: Longitudinal fluoride intakes had little association with bone measures at age 23. As there were no adverse effects from fluoride intake on bone health in young adults, results support the continued use of fluorides, particularly community water fluoridation is the most cost-effective method of dental caries prevention.

11.
Radiography (Lond) ; 2024 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-39244455

RESUMO

OBJECTIVES: To review and evaluate available literature on spectral computed tomography (SCT) bone mineral density (BMD) measurement in adult thoracolumbar vertebrae of unenhanced images compared to quantitative computed tomography (QCT), to understand its current clinical utility. KEY FINDINGS: Keyword searches in four databases identified four cross-sectional studies which acquired an SCT BMD measurement in thoracolumbar vertebrae and compared this respectively to QCT, which were then critically appraised using the AXIS tool for cross-sectional studies. 862 vertebrae were measured between T10-S1 in 368 patients. Three studies demonstrated a statistically significant correlation between SCT and QCT for the measurement of Hydroxyapatite (HAP) and calcium (r = 0.86-0.96). One study demonstrated a diagnostic accuracy of 96% using a receiver operating curve. CONCLUSIONS: SCT measurements of HAP and calcium in the lumbar vertebrae are comparable to QCT for patients with no additional pathology present. However, further research is required to evaluate diagnostic accuracy before clinical application. IMPLICATIONS FOR PRACTICE: SCT BMD measurement has the potential to be developed as a screening tool for osteoporosis within the fracture liaison service (FLS). This could aid in the identification of patients with osteoporosis and address the current treatment gap. Nonetheless, many factors must be considered for this application including staff training, radiation protection and patient engagement with the screening programme.

12.
An. bras. dermatol ; 99(4): 513-519, Jul.-Aug. 2024. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1563694

RESUMO

Abstract Objective To evaluate the effects of rosacea on ocular surface changes such as alterations in dry eye parameters, corneal densitometry, and aberrations, in comparison with healthy controls. Methods A total of 88 eyes of 44 patients diagnosed with rosacea and 88 eyes of 44 healthy controls were enrolled in this cross-sectional study. All participants underwent a comprehensive dermatologic and ophthalmic examination and Tear Break-Up Time (TBUT) and Schirmer-1 tests were performed. The rosacea subtype and Demodex count and OSDI scores of all participants were recorded. Corneal topographic, densitometric, and aberrometric measurements were obtained using the Scheimpflug imaging system. Results The mean age of the 44 patients was 41.2 ± 11.0 years of whom 31 (70.5%) were female. The mean TBUT and Schirmer-1 test values were significantly decreased and OSDI scores were significantly increased in the rosacea group compared to healthy controls (p < 0.01 for all). The most common subtype of rosacea was erythematotelangiectatic rosacea (70.4%). The severity grading of rosacea revealed that 18 (40.9%) patients had moderate erythema. The median (min-max) Demodex count was 14.0 (0-120) and the disease duration was 24.0 (5-360) months. The comparison of the corneal densitometry values revealed that the densitometry measurements in all concentric zones, especially in central and posterior zones were higher in rosacea patients. Corneal aberrometric values in the posterior surface were also lower in the rosacea group compared to healthy controls. The topographic anterior chamber values were significantly lower in the rosacea group. Study limitations Relatively small sample size, variable time interval to hospital admission, and lack of follow-up data are among the limitations of the study. Future studies with larger sample sizes may also enlighten the mechanisms of controversial anterior segment findings by evaluating rosacea patients who have uveitis and those who do not. Conclusion Given the fact that ocular signs may precede cutaneous disease, rosacea is frequently underrecognized by ophthalmologists. Therefore, a comprehensive examination of the ocular surface and assessment of the anterior segment is essential. The main priority of the ophthalmologist is to treat meibomian gland dysfunction and Demodex infection to prevent undesired ocular outcomes.

13.
J Clin Densitom ; 27(4): 101528, 2024 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-39213723

RESUMO

PURPOSE: People with spinal cord injury (SCI) experience a considerable loss of bone after the injury. Lumbar spine (LS) bone mineral density (BMD) has been reported to be within the normal range, or even higher when assessed with DXA, in people with SCI; hence, it has been hypothesized that sources of error may spuriously increase LS BMD. The aim of this study was to describe the frequency of potential sources of error that may alter LS BMD measurement in a cohort of individuals with chronic SCI at baseline and over a 2-year period. METHODS: We analyzed baseline and 2-year follow up DXA scans (Hologic Discovery QDR 4500, Hologic Inc., MA, USA) previously performed from a cohort of males and females with chronic SCI. Two physicians independently reviewed each scan, commented on whether the scan was appropriate for BMD analysis, should be re-analyzed, or be removed from the dataset, and reported on the presence of potential sources of error in LS BMD measurement. RESULTS: We reviewed 115 lumbar spine DXA scans from 58 participants, and 107 (93.0 %) scans from 52 participants presented at least one potential source of error. At baseline, the average number of potential sources of error per scan was 5.5 ± 1.7 and 5.7 ± 1.5 according to rater 1 and rater 2, respectively. Follow-up scans presented an average of 5.6 ± 1.6 and 5.7 ± 1.4 potential sources of error according to rater 1 and rater 2, respectively. Facet sclerosis, osteophytes and difficulty in detecting bone edges were the most prevalent sources of error. CONCLUSION: The high frequency of potential sources of error is consistent with current recommendations against the use of LS BMD for fracture risk assessment in people with SCI.

14.
Eur Radiol Exp ; 8(1): 86, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39090457

RESUMO

BACKGROUND: To investigate the reproducibility of automated volumetric bone mineral density (vBMD) measurements from routine thoracoabdominal computed tomography (CT) assessed with segmentations by a convolutional neural network and automated correction of contrast phases, on diverse scanners, with scanner-specific asynchronous or scanner-agnostic calibrations. METHODS: We obtained 679 observations from 278 CT scans in 121 patients (77 males, 63.6%) studied from 04/2019 to 06/2020. Observations consisted of two vBMD measurements from Δdifferent reconstruction kernels (n = 169), Δcontrast phases (n = 133), scan Δsessions (n = 123), Δscanners (n = 63), or Δall of the aforementioned (n = 20), and observations lacking scanner-specific calibration (n = 171). Precision was assessed using root-mean-square error (RMSE) and root-mean-square coefficient of variation (RMSCV). Cross-measurement agreement was assessed using Bland-Altman plots; outliers within 95% confidence interval of the limits of agreement were reviewed. RESULTS: Repeated measurements from Δdifferent reconstruction kernels were highly precise (RMSE 3.0 mg/cm3; RMSCV 1.3%), even for consecutive scans with different Δcontrast phases (RMSCV 2.9%). Measurements from different Δscan sessions or Δscanners showed decreased precision (RMSCV 4.7% and 4.9%, respectively). Plot-review identified 12 outliers from different scan Δsessions, with signs of hydropic decompensation. Observations with Δall differences showed decreased precision compared to those lacking scanner-specific calibration (RMSCV 5.9 and 3.7, respectively). CONCLUSION: Automatic vBMD assessment from routine CT is precise across varying setups, when calibrated appropriately. Low precision was found in patients with signs of new or worsening hydropic decompensation, what should be considered an exclusion criterion for both opportunistic and dedicated quantitative CT. RELEVANCE STATEMENT: Automated CT-based vBMD measurements are precise in various scenarios, including cross-session and cross-scanner settings, and may therefore facilitate opportunistic screening for osteoporosis and surveillance of BMD in patients undergoing routine clinical CT scans. KEY POINTS: Artificial intelligence-based tools facilitate BMD measurements in routine clinical CT datasets. Automated BMD measurements are highly reproducible in various settings. Reliable, automated opportunistic osteoporosis diagnostics allow for large-scale application.


Assuntos
Densidade Óssea , Tomografia Computadorizada por Raios X , Humanos , Masculino , Tomografia Computadorizada por Raios X/métodos , Feminino , Reprodutibilidade dos Testes , Pessoa de Meia-Idade , Idoso , Adulto , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Redes Neurais de Computação
15.
Eur J Ophthalmol ; : 11206721241267360, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-39147728

RESUMO

PURPOSE: To describe and compare corneal densitometry, subjective refraction, visual acuity, and corneal higher order aberrations (HOA) after corneal refractive surgery using either alcohol-assisted photorefractive keratectomy (aaPRK) or single-step transepithelial PRK (tPRK). METHODS: We conducted a retrospective and observational study. We analyzed 120 right eyes from 120 healthy consecutive myopic patients who underwent aaPRK or tPRK to correct myopia of up to 6 diopters and astigmatism of up to 2 diopters. The WaveLight EX500 excimer laser (Alcon Laboratories, Inc.) was used in all cases. Visual acuity, subjective refraction, and Pentacam AXL® measurements were performed at the preoperative visit and at 6-months follow-up visit. Pentacam AXL® software was used to assess corneal optical density in various annuli for different corneal depths and anterior corneal HOA (6 mm area of analysis). RESULTS: Preoperative spherical equivalent values were similar between groups preoperatively (-3.07 ± 1.52 and -3.38 ± 1.46 in the aaPRK and tPRK groups, respectively). There were no statistically significant differences in visual acuity and postoperative refraction between groups. Postoperative corneal densitometry did not show statistically significant differences in any of the areas studied and both surgical procedures obtained similar results. However, analysis of HOA showed statistically significant differences between the techniques (1.42 ± 0.39 and 1.80 ± 0.62 for the aaPRK and tPRK groups, respectively; p = 0.000). CONCLUSIONS: Both aaPRK and single-step tPRK gave comparable visual, refractive, and corneal density outcomes. Some differences were observed in HOA but were not clinically relevant.

16.
BMC Chem ; 18(1): 157, 2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-39192312

RESUMO

Ipratropium bromide (IPR) and fenoterol hydrobromide (FEN) have recently been combined in a promising inhaler to treat two prevalent inflammatory illnesses of the airways: bronchial asthma and chronic obstructive pulmonary disease (COPD). The necessity for a single, sensitive, and trustworthy analytical approach to cover the diverse and necessary tests of in-vitro and in-vivo studies is greatly grown with the rising production of new fixed combinations. Two novel, selective and environmentally friendly LC techniques were developed in order to guarantee precise measurement of IPR and FEN in their challenging formulation. The initial technique involved high-performance thin-layer chromatography (HPTLC) in conjunction with densitometric quantification. Chromatographic separation was attained on HPTLC plates utilizing ethyl acetate - ethanol - acetic acid (5.0:5.0:0.1, by volume) as a developing system. Densitometric quantification of the separated bands was carried out at 220.0 nm over concentration ranges of 0.50-15.0 µg/band for IPR and 0.50-12.0 µg/band for FEN. High-performance liquid chromatography (HPLC) paired with diode array detection (DAD) was the core of the second technique. The optimized separation was achieved on a Zorbax SB C18 (150 × 4.6 mm, 5 µm) column with a combination of 10.0 mM potassium dihydrogen orthophosphate, pH 5.0 ± 0.1, adjusted with o-phosphoric acid and methanol (70:30, v/v) as the mobile phase and pumped at flow rate of 1.0 mL/min. The peaks were monitored at 220.0 nm using diode array detection, achieving linearity range of 5.0-200.0 µg/mL for both drugs. The ICH criteria have been verified and both methods have been confirmed to be valid, and successfully applied for assay the cited drugs in the Atrovent® comp HFA metered dose inhaler as well as delivered dose uniformity testing of the final product. Finally, whiteness appraisal and several state-of-the-art green evaluation metrics were applied to evaluate the sustainability of the proposed methods. The suggested approaches produced promising results and are the first simple and sustainable methodologies for the simultaneous quantification of both drugs in different real samples, all of which strongly suggest their application in quality control laboratories.

17.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-39128695

RESUMO

Vertebral compression fractures by osteoporosis (OVF) is usually a diagnostic problem and coincides on the age group of metastatic vertebral compression fractures (MVF). Although radiography is the first diagnostic technique, generally is not accurate for depicting demineralization and soft tissue lesions. Magnetic resonance (MRI) is the diagnostic choice. The most relevant signs are intravertebral fluid collection or fluid signal, other vertebral deformities without oedema and older age. Among the most relevant findings for diagnosis MVF are soft tissue mass and pedicle intensity signal asymmetries. However, reproducibility of these findings in clinical practice is moderate.

18.
J Clin Imaging Sci ; 14: 26, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39108316

RESUMO

Objectives: Although sarcopenia is recognized as one of the risk factors for increased morbidity after resection for colorectal cancer, the question of the most appropriate way to identify and quantify it is still unresolved. Material and Methods: This is a retrospective unicentric study following patients undergoing elective resection of the rectum for carcinoma with available staging computed tomography (CT) of the trunk. Psoas muscle density (PMD) and its area relative to patient height psoas muscle index (PMI) at the level of inferior vertebral end plate of third lumbar vertebra (L3) were assessed using an initial staging CT scan of the trunk. Post-operative complications, evaluated according to the Clavien-Dindo classification, and blood samples on post-operative days (POD) 3 and 5 were also recorded in the study population. Patients were divided into groups with complicated and uncomplicated post-operative course, and observed parameters were then statistically compared. Results: The correlation of PMI values with the development of post-operative complications was not confirmed in a data set of 206 patients. PMD values were found to be borderline statistically significant in patients with complicated post-operative course, while in the group of patients with severe complications (Clavien-Dindo III-IV), there was no statistically significant difference in PMI or PMD values. The same results were obtained when comparing patients with anastomotic leak (AL). It was confirmed that operations on the lower rectum are riskier for the development of post-operative complications. The secondary objective of our study regarding serum C-reactive protein (CRP) levels of 3rd and 5th POD gave us the answer in the form of cutoff values of 115.7 mg/L (3rd POD) and 76 mg/L (5th POD). Conclusion: PMD appears to be a promising tool for predicting post-operative morbidity in patients after rectal resection, but a clear consensus on the method of measurement, interpretation of results and cutoff values is needed. Lower rectal resections are burdened with a higher risk of post-operative complications, especially AL. Monitoring of CRP levels remains an important marker in the prediction of AL due to its negative predictive value.

19.
Artigo em Inglês | MEDLINE | ID: mdl-39206082

RESUMO

Background: Pseudoexfoliation syndrome (PES) is an age-related systemic condition that predominantly affects ocular structures and is characterized by the deposition of material on the lens, ciliary body, zonules, corneal endothelium, iris, and pupillary margin. We compared the corneal endothelial morphology, anterior segment parameters, corneal densitometry, and corneal topographic characteristics between the clinically affected and apparently normal fellow eyes of patients with clinically unilateral PES. Methods: This was a comparative, cross-sectional study of 34 patients with clinically unilateral PES. The anterior segment was examined using a Scheimpflug imaging system, and the corneal endothelium was assessed using a noncontact specular microscope. Corneal endothelial cell density, polymegathism, and pleomorphism were assessed using the specular microscope. Furthermore, the Scheimpflug camera was used to measure the corneal power of the flat and steep axis, mean corneal power, maximum keratometry, anterior chamber angle, anterior chamber depth, anterior chamber volume, corneal volume, and the corneal thickness at the apex point, center of the pupil, and the thinnest point. Corneal densitometry was evaluated at two concentric zones (0-2 mm and 0-12 mm). Results: In total, 68 eyes from 34 patients were ultimately included in the study. The mean (standard deviation) age of the patients was 73.38 (8.75) years (range: 50-87 years). Among the included patients, 17 (50%) were male and 17 (50%) were female. The anterior segment parameters did not significantly differ between eyes with PES and their clinically unaffected fellow eyes (all P > 0.05). Similarly, no statistically significant difference was observed in corneal endothelial morphology (all P > 0.05). Conclusions: Our measured parameters do not differ between the clinically affected eye and the clinically unaffected fellow eye. This supports the theory that PES is a bilateral disorder. Considering the variety of complications associated with PES, bilateral involvement should be assumed in the clinical and surgical management of patients with clinically unilateral PES. In the future, new research could increase our understanding of this syndrome.

20.
Pharmaceuticals (Basel) ; 17(8)2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39204107

RESUMO

A cost-effective, selective, sensitive, and operational TLC-densitometric approach has been adapted for the concurrent assay of Hydroxyzine Hydrochloride (HYX), Ephedrine Hydrochloride (EPH), and Theophylline (THP) in their pure powder and pharmaceutical forms. In the innovative TLC-densitometric approach, HYX, EPH, and THP were efficaciously separated and quantified on a 60F254 silica gel stationary phase with chloroform-ammonium acetate buffer (9.5:0.5, v/v) adjusted to pH 6.5 using ammonia solution as a mobile liquid system and UV detection at 220 nm. The novel TLC method validation has been performed in line with the international conference for harmonization (ICH) standards and has been effectively used for the estimation of the researched medicines in their pharmaceutical formulations without intervention from excipients. Additionally, parameters affecting the chromatographic analysis have been investigated. The new TLC approach's functionality and greenness were appraised using three modern and automated tools, namely the Blue Applicability Grade Index (BAGI), the Analytical Greenness metric (AGREE), and the Green Analytical Procedure Index (GAPI) tools. In short, the greenness characteristics were not achieved as a result of using mandatory, non-ecofriendly solvents such as ammonia and chloroform. On the contrary, the applicability and usefulness of the novel TLC approach were attained via concurrent estimation for the three drugs using simple and straightforward procedures. Moreover, the novel TLC method outperforms previously published HPLC ones in terms of the short run time per sample and moderate pH value for the liquid system. According to the conclusions of comparisons with previously recorded TLC methods, our novel HPTLC method has the highest AGREE score, so it is the greenest HPTLC strategy. Moreover, its functionality and applicability are very appropriate because of the simultaneous assessment of three drugs in one TLC run. Furthermore, no tedious and complicated extraction and evaporation processes are prerequisites.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA