Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Cureus ; 16(8): e66054, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39224719

RESUMO

Introduction Canal preparation is a critical step in endodontic therapy. Introducing nickel-titanium (NiTi) rotary instruments has significantly reduced the likelihood of errors in curved canals. However, due to their price, these instruments are often reused following autoclaving. The aim of this study is to compare and evaluate the surface characteristics of two designs of rotary NiTi files used in curved canals and subjected to multiple autoclaving cycles, utilizing an atomic force microscope for detailed analysis. Methods A total sample size of 24 files was taken, 12 files of Hyflex EDM (Coltene/Whaledent, Germany) files and WaveOne Gold (Dentsply Sirona, USA) files were then divided into four groups (n=6) as follows: Group I: Hyflex EDM control group; Group II: WaveOne Gold control group; Group III: Hyflex EDM experimental group; Group IV: WaveOne Gold experimental group. Sterilization using an autoclave was performed thrice for Groups I and II files. The files in Groups III and IV were used in simulated curved canals three times and autoclaved after each use. Atomic force microscopy was used to assess the surface roughness of the files after the first and third autoclave cycles. Results The results showed that, without statistical significance, Hyflex EDM exhibited the highest surface roughness after the first usage among the two file systems. Conclusion It can be concluded that both Hyflex EDM and WaveOne Gold files produced similar levels of surface changes when subjected to multiple usage and autoclaving cycles.

2.
Saudi Dent J ; 36(4): 656-660, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38690374

RESUMO

Introduction: Comparative evaluation of the newly introduced; RACE EVO file system to the currently well-performing file systems like HyFlex EDM OneFile, Vortex Blue, ProTaper Gold (PTG) with regards to the cyclic fatigue resistance. Materials: &Methods.The endodontic rotary files under evaluation were segregated into four groups as follows:; RACE EVO, PTG, Vortex Blue, and HyFlex EDM OneFile. A detailed physical analysis of the cyclic fatigue resistance was performed in 15 files of each type (n = 60). Under the test conditions of 37 °C the test samples were subjected to continuous motion at the manufacturer recommended speed within an artificial curved canal until it fractured. For all the test samples, with the recording of time of fracture, calculation was done for number of cycles to fracture (NCF). In addition, the length of the fractured segment was determined. The fractured surface was further evaluated with scanning electron microscopic (SEM) images. Results: Highest significance for NCF was seen in HyFlex EDM OneFile followed by the Vortex Blue, PTG, and; RACE EVO (p < 0.05) by analyzing the data statistically. Significant differences among the lengths of the fractured segments were evident among tested files, ranging between 4.73 and 6.3 mm (p < 0.05) with HyFlex EDM OneFile uniquely differentiating from the others showing the fracture at 6.3 mm. The common features of cyclic fatigue failure was further substantiated by SEM images. Conclusions: Compared to the HyFlex EDM OneFile, Vortex Blue, and PTG files; RACE EVO demonstrated significantly lower resistance to cyclic fatigue.

3.
Cureus ; 16(3): e56466, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38638716

RESUMO

BACKGROUND: Despite substantial breakthroughs in instrumentation systems and pharmaceutical interventions, pain following endodontic therapy remains a serious concern. The effect of the type of endodontic instrumentation system in post-operative pain after endodontic therapy has been a matter of debate. AIM: To evaluate different endodontic instrumentation systems, namely Reciproc (GmbH, Munich), OneShape® (MicroMega, France), Protaper Gold (Dentsply Sirona, USA), and Hyflex® EDM (Coltène/Whaledent Inc., USA) file systems, regarding post-operative pain after endodontic therapy Methods and materials: The endodontic department treated healthy patients aged 20 to 50 years who were experiencing symptoms of irreparable pulpitis in one or more maxillary molars or mandibular molars. Five hundred was the determined size of the sample. The study participants were divided into five categories, each comprising 100 participants. These categories were: Category 1: Reciproc instrumentation system. Category 2: OneShape® instrumentation system. Category 3: ProtaperGold instrumentation system. Category 4: HyFlex® EDM instrumentation system. Category 5: Control (stainless steel K-files). Following endodontic therapy, these scores were recorded at 6 hours, 12 hours, 24 hours, 48 hours, and 72 hours using the VAS scale. RESULTS: The visual analog scale (VAS) score (mean±SD) in the control group was 0.73± 0.40 (<0.001). The VAS score in the Reciproc group was 0.43± 0.05 (<0.001). The VAS score in the OneShape® group was 0.36±0.09 (<0.001). The VAS score in the Protaper Gold group was 0.41 ±0.08 (<0.001). The VAS score in the HyFlex® EDM group was 0.55 ±0.02 (<0.001). The VAS score in all instrumentation techniques at 72 hours follow-up was lesser in comparison to a control group with meaningful statistical significance (<0.001). However, the post-operative pain among the Reciproc, OneShape®, Protaper Gold, and HyFlex® EDM instrumentation systems was not different clinically when compared among themselves. However, VAS values were greater in OneShape® and HyFlex® EDM compared to Reciproc and Protaper Gold, showing increased post-operative pain in OneShape and HyFlex® EDM compared to Reciproc and Protaper Gold. It was also observed that there was a decline in the VAS score in all instrumentation systems as the follow-up period increased from 6 hours to 72 hours, with maximum post-operative pain at 6 hours of follow-up and minimum post-operative pain at 72 hours of follow-up. However, the decline was lesser in OneShape® and HyFlex® EDM in comparison to Reciproc and Protaper Gold, with increased post-operative pain in OneShape® and HyFlex® EDM in comparison to Reciproc and Protaper Gold. CONCLUSION: Post-operative pain at all follow-ups of endodontic procedures was less in Reciproc, OneShape®, Protaper Gold, and HyFlex® EDM than in the control group. VAS scores were higher in the OneShape® and HyFlex® EDM groups compared to the Reciproc and Protaper Gold groups, indicating increased post-operative pain with OneShape® and HyFlex® EDM instruments in comparison to Reciproc and Protaper Gold.

4.
BMC Oral Health ; 23(1): 902, 2023 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-37990209

RESUMO

OBJECTIVES: To evaluate the amount of remaining filing material and apical debris extrusion after retreatment using Reciproc Blue, Hyflex EDM and ProTaper Retreatment Files. MATERIALS AND METHODS: Thirty-six extracted permanent mandibular first molars with moderately curved mesial roots were selected. Mesiobuccal canals were prepared using the ProTaper Next system up to size X2 and filled using gutta-percha and Adseal sealer via cold lateral compaction. Teeth were randomly divided into three equal groups (n = 12): Group 1: Reciproc Blue (RB)(VDW, Germany), Group 2: Hyflex EDM (HEDM)(Coltene/Whaledent, Switzerland), Group 3: ProTaper Universal Retreatment file system + ProTaper Next file system (PTUR + PTN)( Dentsply Maillefer, Switzerland). Eppendorf tubes were used to collect the apically extruded debris. Cone-beam computed tomographic scans were taken prior to and after retreatment and the volume of remaining filling material was assessed at the coronal, middle and apical levels. Statistical analysis was performed using the Kruskal-Wallis test, Friedman's test and Wilcoxon Sign Rank test. Significance level was set at p value 0.05. RESULTS: There were no statistically significant differences among the three groups in the reduction of the volume of the filling material or in the amount of apically extruded debris. CONCLUSION: All the tested filing systems showed similar efficacy in removing the filling material, however, none of them could achieve its complete removal. Apical extrusion of debris occurred with all the systems used with no significant difference between the three groups.


Assuntos
Materiais Restauradores do Canal Radicular , Dente , Humanos , Preparo de Canal Radicular/métodos , Obturação do Canal Radicular/métodos , Guta-Percha , Cavidade Pulpar/cirurgia , Retratamento
5.
J Pharm Bioallied Sci ; 15(Suppl 2): S1072-S1074, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37693987

RESUMO

Background and Objectives: The aim of this study was to see the incidence of cracks in root dentin after coronal flaring using various rotary instruments such as Gates Glidden (GG) drills, ProTaper Universal SX, OneFlare, and HyFlex EDM. Materials and Methods: Seventy freshly extracted premolar teeth with single canal were collected. All the teeth were randomly divided into five groups of fourteen each (n = 14), of which one group served as the control and the rest of the four groups were instrumented with GG drills, ProTaper Universal SX, OneFlare, and HyFlex EDM, respectively. Results: The GG drills resulted in a higher rate of crack formation in root dentin (P < 0.05) than the ProTaper Universal SX, OneFlare, and HyFlex EDM instruments (P > 0.05). Conclusion: The use of GG drills resulted in more crack formation. However, the results for the ProTaper Universal SX, OneFlare, and HyFlex EDM flaring instruments were less in terms of crack formation.

6.
Aust Endod J ; 49(3): 592-598, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37592880

RESUMO

The aim of this study was to compare the cyclic fatigue resistance of nickel-titanium instruments inside single and double-curved canals at different temperatures. 160 HyFlex EDM #20.05 (HEDM), VDW.ROTATE #20.05 and #25.06, Mtwo #25.06 were randomised (n = 10) for the dynamic cyclic fatigue tests according to the curvature (i.e. single and double) at 20° ± 1°C and 35° ± 1°C. The number of cycles to fracture (NCF) was analysed by two-way ANOVA with p < 0.05. Fatigue resistance of all instruments significantly decreased at body temperature in single and double curvatures, except for HEDM in double curvature. The NCF was significantly lower in double curvature than single at both temperatures for all files, except for VDW.ROTATE #20.05 at 35° ± 1°C. Within the study limitations, temperature significantly impaired cyclic fatigue resistance of all files except HEDM #20.05 in double curvature. Similarly, double curvature had a detrimental effect on cyclic fatigue resistance of all files except for VDW.ROTATE #20.05 at body temperature.


Assuntos
Instrumentos Odontológicos , Níquel , Titânio , Temperatura Corporal , Ligas Dentárias , Desenho de Equipamento , Falha de Equipamento , Teste de Materiais , Preparo de Canal Radicular , Resistência à Flexão
7.
Cureus ; 15(5): e38829, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37303406

RESUMO

AIM: This study set out to compare the damage done to dentin by three distinct titanium file brands - the Hyflex EDM, the ProTaper Next, and the Waveone Gold Nickel - in order to draw conclusions about which one is the most effective. MATERIALS AND METHODS: Forty-first premolars in the mandible with straight canals and single roots were instrumented using Hyflex EDM, Waveone Gold, and Protaper Next. Dentinal flaws after endodontic treatment were studied by sectioning specimens using a hard tissue microtome and analyzing them under a stereomicroscope. RESULTS: There was no discernible variation between the groups in the coronal third (p=0.312) or apical third (p=0.076). Hyflex EDM and Protaper Next differed significantly in the middle portion of the tape (p=0.016). The Hyflex EDM sample had the fewest cracks. There was no statistically significant difference between Hyflex EDM and Waveone Gold; however, Hyflex EDM had fewer fractures in the middle third of the sample than Waveone Gold did. CONCLUSION: Electric discharge machining (EDM) files made from Hyflex proved to be far superior to their Protaper Next and Waveone Gold counterparts as they induced the fewest cracks in the middle third of the root dentin.

8.
BMC Oral Health ; 23(1): 174, 2023 03 25.
Artigo em Inglês | MEDLINE | ID: mdl-36966308

RESUMO

BACKGROUND: The aim of this study was to compare the efficacy of K-type stainless steel hand instruments (Mani Inc. ), Fanta AF™ Ledge Correction (LC) (Fanta Dental), and Hyflex EDM (Coltene-Whaledent) for ledge correction, canal transport, centric ability, and shaping (preparation) time after an artificial ledge has been bypassed manually in highly curved canals using acrylic blocks. METHODS: Forty-two resin blocks, each with a radius of 5 mm (Endo Trainer Block, VDW) and an apical inclination of 55°, were used. Under stereomicroscope magnification, standard artificial ledges were created on acrylic blocks, and attempts were then made to eliminate them using hand instruments, FantaAF™ LC, and Hyflex EDM. Before and after images were obtained using a stereomicroscope and compared using Photoshop. RESULTS: Fanta AF™ LC and Hyflex EDM were found to be more effective for correcting ledges than hand instruments. The use of hand instruments resulted in the greatest transportation away from the canal curvature in the apical area. The canal shaping was completed in the shortest amount of time using Fanta AF™ LC, followed by HyFlex EDM and then the hand instruments. CONCLUSION: In terms of centric ability, the order from best to worst is as follows: Fanta AF™ LC, Hyflex EDM, and hand instruments. After the ledge was manually bypassed with hand instruments in the root canals, Hyflex EDM and Fanta AF™ LC were found to be more effective than hand instruments in reshaping the previously unreachable region between the ledge and the foramen apical.


Assuntos
Preparo de Canal Radicular , Titânio , Humanos , Níquel , Microscopia , Cavidade Pulpar , Instrumentos Odontológicos
9.
Aust Endod J ; 49(1): 111-116, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35583852

RESUMO

This study investigated the accuracy of two electronic apex locators (DentaPort and Bingo) using heat-treated nickel-titanium files. The true root canal length of 30 single-rooted teeth was determined using K files. Next, the electronically measured length was determined using two nickel-titanium files (ProGlider and HyFlex EDM Glide Path File) with two electronic apex locators at the 'APEX' marks. The accuracy of the electronic apex locator was evaluated by comparing the true root canal length and electronically measured length for each measurement. There was no significant difference between the measurements with two nickel-titanium files, and all differences between true root canal length and electronically measured length were within ±0.5 mm regardless of the type of nickel-titanium files or electronic apex locators. Based on the results, the heat treatment of the nickel-titanium files showed no adverse effects on the working length determination using electronic apex locators.


Assuntos
Níquel , Preparo de Canal Radicular , Preparo de Canal Radicular/métodos , Titânio , Temperatura Alta , Eletrônica , Ápice Dentário , Cavidade Pulpar , Odontometria
10.
J Dent Anesth Pain Med ; 22(4): 267-275, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35991361

RESUMO

Background: Various instrument kinematics used in single-visit endodontics influence the occurrence of pain after endodontic therapy. This study aimed to evaluate the occurrence of pain after mechanical instrumentation with Hyflex EDM (HEDM) and WaveOne Gold (WOG) during single-visit endodontic therapy. Methods: Sixty patients diagnosed with asymptomatic irreversible pulpitis and normal apical tissues in mandibular premolar teeth were included in the study for single-visit root canal therapy. The patients were divided into two groups (n = 30) according to the rotary instrument used during root canal preparation (group A [HEDM] and group B [WOG]). Pain was evaluated after endodontic therapy at 8, 24, and 48 h intervals using the visual analog scale (VAS). Data obtained were analyzed using the chi-square test, independent t-test, MannWhitney U test, and Wilcoxon matched-pairs test. Results: Statistically significant differences were observed between the two groups (P < 0.001) at 8, 24, and 48 h, with WOG exhibiting less pain than HEDM files. Conclusion: Postoperative pain was lower in the WOG file system than in the HEDM file system after single-visit root canal therapy at 8, 24, and 48 h.

11.
J Conserv Dent ; 25(3): 269-273, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35836559

RESUMO

Introduction and Aim: Postoperative inflammation and endodontic failure occur due to apical extrusion of debris. The purpose of this in vitro study was to assess the amount of apically extruded debris during the root canal preparation using rotary and reciprocating nickel-titanium instrumentation systems. Materials and Methods: The mesiobuccal canals of seventy five mature, human mandibular molars were randomly divided into three groups (n = 25 teeth/group). Each group was instrumented using one of the three different instrumentation systems: Hyflex EDM (HEDM) rotary file, Flexicon X7 rotary, and Flexicon X1 reciprocating files. The canals were irrigated using distilled water. The debris extruded apically was collected in preweighed Eppendorf tubes and assessed with an electronic balance and compared. Statistical Analysis: Data were statistically analyzed by one-way analysis of variance and the intergroup comparison with single factor ANOVA. Results: The Flexicon X1 reciprocating system showed the maximum amount of apical extrusion of debris among all the groups. The least amount of debris was observed in Flexicon X7 rotary instrument (P > 0.05). Conclusion: Flexicon X7 rotary extruded significantly lesser amount of debris than Flexicon X1 reciprocating and HEDM rotary file systems.

12.
Braz. dent. sci ; 25(4): 1-8, 2022. tab, ilus
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-1411321

RESUMO

Objective: To investigate the effect of room and body temperatures on cyclic fatigue resistance of three endodontic nickel-titanium rotary files: Hyflex EDM (HEDM) (Coltene/Whaledent, Switzerland), WaveOne Gold (WOG) (Dentsply Maillefer, Switzer), and EdgeOne Fire (EOF) (EdgeEndo, Albuquerque, New Mexico, USA) in a double- curved canal. Material and Methods: In this study, Sixty NiTi rotary files were used. These files were divided into three groups (n = 20 for each group). Group A: HEDM (size 25, taper 0.08), group B: WOG (size 25, taper 0.07), and group C: EOF (size 25, taper 0.07). Each group was subdivided into two subgroups (n=10 for each subgroup). One of the subgroup was subjected to cyclic fatigue test at room temperature (20±1°C), while the other subgroup was subjected to cyclic fatigue test at body temperature (37±1°C). These files were tested by using a custom-made artificial canal with a double curvature (coronal curve: 60° curvature with 5 mm radius; apical curve: 70° curvature with 2 mm radius). All instruments were rotated according to the manufacturer instructions until the fracture occurred by using electric endodontic motor (Wave One, Dentsply Maillefer, Ballaigues, Switzerland). The number of cycles to fracture (NCF) and the fractured fragment length (FL) were recorded for each endodontic file. The data were gathered and statistically analyzed using shapiro-wilk test and two-way ANOVA test. The statistical significance was set at 0.05. Results: The NCF of WOG and EOF were significantly lower at body temperature as compared to room temperature (p ≤ 0.05), whereas no difference was observed in NCF of HEDM at body and room temperatures (p>0.05). At 20±1°C, the results showed a non-significant difference between NCF of WOG and EOF (p>0.05), while the NCF of HEDM was significantly lower than the other groups (p ≤ 0.05). At 37±1°C, the results showed a non-significant difference in NCF among the tested endodontic files (p ≤ 0.05). There is non-significant difference in FL of each group at (20±1°C) and (37±1°C) (p>0.05). No statistical difference in FL among the tested files at room and body temperatures (p>0.05). Conclusion: The temperature has a significant effect on cyclic fatigue resistance of EOF and WOG, whereas no effect was observed on cyclic fatigue resistance of HEDM. WOG and EOF had a comparable NCF, while HEDM had a lower NCF than other groups at room temperature. At body temperature, all tested files have a comparable NCF. These results were attributed to the type of the alloy and heat treated that was used to manufacture these endodontic files. The cyclic fatigue test should be done at body temperature (AU)


Objetivo : Investigar o efeito das temperaturas ambiente e corpórea na resistência a fadiga cíclica em três instrumentos endodônticos rotatório de níquel-titânio: Hyflex EDM (HEDM)(coltene/Whaledent, Switzerland), WaveOne Gold (WOG) Dentsply Maillefer, Switzer), e EdgeOne Fire (EOF) (EdgeEndo, Albuquerque, New Mexico, USA) em canais com dupla curvatura. Material e Métodos : Neste estudo foram utilizadas sessenta limas endodônticas rotatórias. Esses grupos foram divididos em três grupos (n=20). Grupo A: HEDM (tamanho 25, conicidade 0.08), grupo B: WOG (tamanho 25, conicidade 0.07), e grupo C: EOF (tamanho 25, conicidade 0.07). Cada grupo foi subdivididos em dois subgrupos (n=10). Um dos subgrupos foi submetido ao teste de fadiga cíclica em temperatura ambiente (20±1°C), enquanto o outro subgrupo foi submetido a ao teste de fadiga cíclica em temperatura corpórea (37±1°C). Essas limas foram testadas em um canal artificial feito sob medida com duas curvaturas (curva coronal: curvatura de 60º e com 5 mm de raio; curva apical: curvatura de 70º com 2mm de raio); Todos os instrumentos foram rotacionados de acordo com a instrução do fabricante até que a fratura ocorresse utilizando um motor endodôntico elétrico (Wave One, Dentsply Maillefer, Ballaigues, Switzerland). O número de ciclos até a fratura (NCF) e a comprimento do fragmento fraturado (FL) foram registrados para cada lima endodôntica. Os dados foram coletados e analisados pelo teste shopiro-wilk e ANOVA two-way. A significância estatística foi 0.05. Resultados: O NCF do WOG e do WOF foi significantemente menor na temperatura corpórea em comparação à temperatura ambiente (p ≤ 0.05), enquanto não foi observada diferença entre NCF em HEDM em temperatura corpórea e temperatura ambiente (p>0.05). Em 20±1°C, os resultados mostraram diferença não significativa entre o NFC com WOG e EOF (p>0.05), enquanto o NCF com HEDM foi significante menor que os demais grupos (p ≤ 0.05). A 37±1°C, os resultados mostraram diferença não significativa em NCF entre as limas endodônticas testadas (p ≤ 0.05). Há diferença não significativa no FL de cada grupo (20±1°C) e (37±1°C) (p>0.05). Não houve diferença estatisticamente diferente no FL entre as limas testadas nas temperaturas ambiente e corporal (p>0,05). Conclusão: A temperatura tem efeito significativo na resistência a fadiga cíclica do EOF e WOG, enquanto não foi observado nenhum efeito na resistência a fadiga cíclica do HEDM. WOG e EOF tiveram um NCF comparável, enquanto HEDM teve um NCF menor do que os outros grupos em temperatura ambiente. À temperatura corporal, todas as limas testas apresentam semelhante NCF. Esses resultados foram atribuídos ao tipo de liga e ao tratamento térmico que foi utilizado na fabricação. O teste de fadiga cíclica deve ser feito à temperatura corporal (AU)


Assuntos
Temperatura Corporal , Análise de Variância , Instrumentos Odontológicos , Fadiga
13.
J Contemp Dent Pract ; 22(2): 117-121, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34257168

RESUMO

AIM: This study was carried out to compare canal transportation in three new rotary file systems, namely TruNatomy, ProTaper Gold, and Hyflex Electric Discharge Machining file system, using cone-beam computed tomography. MATERIALS AND METHODS: The study was conducted on 105 extracted teeth consisting of 60 extracted mandibular first molars and 45 mandibular second premolars involving the mesiolingual canal of mandibular first molar and the root canal of second premolar. The teeth were randomly divided into three groups of 35 out of which each group consisted of 20 mandibular first molars and 15 mandibular second premolars. The TruNatomy rotary file was used in group I, ProTaper Gold was used in group II, and Hyflex Electric Discharge Machining was used in group III. Cone-beam computed tomography scan images were obtained both before and after instrumentation. Changes caused by preparation in the coronal, middle, and apical thirds were determined on cone-beam computed tomography scans and analyzed using the Kruskal-Wallis test at p ≤ 0.05 level of significance. RESULTS: TruNatomy showed least amount of canal transportation as compared with other two file systems at all the three levels of canals. ProTaper Gold showed maximum amount of canal transportation as compared with other two file systems at all the three levels of canals. The Hyflex EDM rotary file system showed transportation, which was more than the TruNatomy file system while it was less than that of ProTaper Gold. The difference was statically significant at the middle one-third level (p = 0.03) and at the coronal level (p = 0.02). CONCLUSION: The TruNatomy system has least amount of canal transportation as compared with ProTaper Gold and Hyflex EDM system. With potential to preserve tooth structure, this file has an added advantage over other rotary file systems. CLINICAL SIGNIFICANCE: The TruNatomy file system has been recently introduced with good cyclic fatigue resistance. It is necessary to evaluate the root canal transportation caused by the TruNatomy file.


Assuntos
Ouro , Preparo de Canal Radicular , Tomografia Computadorizada de Feixe Cônico , Cavidade Pulpar , Desenho de Equipamento , Humanos , Alta do Paciente
14.
Niger J Clin Pract ; 24(3): 418-424, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33723118

RESUMO

OBJECTIVES: The aim of this study was to compare the formation of dentinal crack after root canal preparation performed with different heat treated single-file systems. MATERIALS AND METHODS: Forty mandibular premolar teeth were randomly divided into four groups according to the file system to be used during the preparation (n = 10): Group 1: Reciproc Blue; group 2: One Curve; group 3: HyFlex EDM; group 4: (control group) hand files. During the cleaning and shaping, irrigation was performed with a total of 10 ml of 5.25% sodium hypochlorite and 2 mL of distilled water. Then sections were taken from the roots (3, 6 and 9 mm). Sections were examined on a stereomicroscope to determine the presence of cracks. Chi-square test was used for data analysis. RESULTS: There was a significant difference between the groups in dentinal crack frequency (P <.05). HyFlex EDM (13.3%) caused less dentinal crack than One Curve (26.7%) and Reciproc Blue (30%). No cracks were observed in the control group. When 3, 6, and 9 mm were evaluated within themselves, dentinal crack formation did not differ according to the groups (P > 0.05). A statistically higher mean value was obtained in the control group compared to the other groups in terms of working time (P < 0.001). CONCLUSIONS: All the files used during root canal preparation formed dentin crack. Hy-Flex EDM caused less dentinal cracks than other file systems. The flexibility of nickel-titanium instruments because of heat treatment seems to have a significant influence on dentinal crack formation.


Assuntos
Dentina , Temperatura Alta , Mãos , Humanos , Preparo de Canal Radicular , Hipoclorito de Sódio
15.
BMC Oral Health ; 21(1): 150, 2021 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-33757499

RESUMO

BACKGROUND: This randomized clinical trial aimed to compare the preparation time and severity of postoperative pain between HyFlex Electric Discharge Machine (EDM) glide path file (GPF) and PathFile. METHODS: Eighty patients whose molar teeth had at least one severely curved canal were treated by the same specialist. After access cavity preparation, the patients were randomly assigned to receive glide path enlargement with either HyFlex EDM GPF or PathFile. ProTaper Next X1 and X2 files were used to prepare the canals. The time of preparation was assessed and the severity of postoperative pain over the next 7 days was recorded. The preparation time and the postoperative pain scores were compared using the Linear Mixed Models (P ≤ 0.05). RESULTS: Glide path enlargement time was significantly shorter with HyFlex EDM GPF (27.828 ± 2.345 s) than with PathFile (48.942 ± 2.864 s) (P < 0.001). The highest postoperative pain score was recorded on the first day and the pain decreased over time in both groups. HyFlex EDM GPF group patients reported significantly less postoperative pain than PathFile group patients overall (P < 0.001). CONCLUSIONS: Postoperative pain and glide path preparation time could be reduced by using HyFlex EDM GPF system. Trial registration PKUSSNCT, PKUSSNCT-17B12, Registered 24 October 2017.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Desenho de Equipamento , Humanos , Dente Molar/cirurgia , Dor Pós-Operatória , Titânio
16.
J Contemp Dent Pract ; 22(11): 1243-1249, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-35343448

RESUMO

AIM AND OBJECTIVE: To compare and analyze the cyclic fatigue resistance of novel TruNatomy files against the conventionally used rotary files and reciprocating files in a simulated canal system with curvatures in the middle, apical portions root, and S-shaped canal employing scanning electron microscopy. MATERIALS AND METHODS: Endodontic files tested in the study include ProTaper, HyFlex EDM, Reciproc blue, and TruNatomy files operated in a simulated root canal system. A total of 96 files were employed in this study. They were categorized into four groups. Group 1 employed 24 TruNatomy files, group 2 employed 24 ProTaper gold files, group 3 employed 24 HyFlex EDM files, and group 4 employed 24 Reciproc blue files. All the groups employed eight files each under three subgroups namely A, B, and C representing middle, apical, and double curvatures, respectively. Artificial grooves were incorporated in the stainless steel blocks having three different curvatures. All the file systems were operated with a torque-controlled electric motor. The files were engaged in the artificial canal until the occurrence of fracture. The time required for the fracture was noted. Length of fractured tip was measured using the digital Vernier caliper. The number of cycles of failure (NCF) was calculated. The fractured parts were subjected to scanning electron microscope to analyze the mode of fracture. RESULTS: TruNatomy files had the highest mean NCF values of 588.01 in middle curvature, 1,321 in apical curvature, and 642.5 in S-shaped curvature HyFlex EDM and Reciproc blue file system exhibited comparable cyclic fatigue resistance among them. ProTaper gold file system exhibited least mean NCF values of 158.13 in the middle, 196.5 in the apical curvature, and 116.88 in the S-shaped canal system. Middle portion fractured first than the apical curvature. The mean length of fractured segments was found to be insignificant among the experimental study groups tested. CONCLUSION: All the file systems employed in the study had good cyclic fatigue resistance while TruNatomy files had the highest cyclic fatigue resistance while HyFlex EDM and Reciproc blue had comparable fatigue resistance. ProTaper gold file system had the least fatigue resistance at different radius of curvature in the simulated canal system in the apical and middle portions and S-shaped root canal. CLINICAL SIGNIFICANCE: The selection of file systems in cleaning and shaping protocols is an enigma to the endodontics. This in vitro study explored the selection protocols for the execution of root canal preparation. Heat treatment of nickel-titanium (NiTi) endodontic files had improved the cyclic fatigue résistance significantly enhancing the clinical life of file systems.


Assuntos
Instrumentos Odontológicos , Preparo de Canal Radicular , Ligas Dentárias , Falha de Equipamento , Teste de Materiais
17.
Niger J Clin Pract ; 23(1): 41-45, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31929205

RESUMO

OBJECTIVE: This in vitro study aimed to compare the cyclic fatigue resistance of HyFlex EDM (HEDM), Vortex Blue (VB), ProTaper Gold (PG), and OneCurve (OC) nickel-titanium (NiTi) instruments. MATERIALS AND METHODS: About 12 HEDM (25/.~), 12 VB (25/.06), 12 PG (25/.08), and 12°C (25/.06) instruments were included in this study. All the instruments were tested with a 60° angle of curvature and a 3-mm radius of curvature. All the instruments were utilized until fracture occurred, and then the number of cycles to failure (NCF) was calculated. The data were analyzed statistically using Kruskal-Wallis H and Mann-Whitney U-tests. The statistical significance level was set at P < 0.05. RESULTS: HEDM instruments had the highest cyclic fatigue resistance among all the other instruments (P < 0.05). The OC instruments had a significantly higher fatigue resistance than the PG and VB instruments (P < 0.05); however, there was no significant difference between PG and VB instruments in the NCF (P > 0.05). CONCLUSION: Within the limitations of this in vitro study, it was found that the cyclic fatigue resistance was higher for the HEDM instruments than for the VB, PG, and OC instruments.


Assuntos
Ligas Dentárias/química , Instrumentos Odontológicos , Falha de Equipamento , Teste de Materiais , Preparo de Canal Radicular/instrumentação , Ligas , Desenho de Equipamento , Ouro , Humanos , Níquel/química , Titânio/química
18.
Artigo em Inglês | MEDLINE | ID: mdl-31857861

RESUMO

Background. This study examined the effects of changes in temperature and environmental conditions on the cyclic fatigue resistance of Reciproc Blue, HyFlex EDM, WaveOne Gold, and Twisted File Adaptive. Methods. Forty-five Reciproc Blue (25/.08), 45 HyFlex EDM (25/.08), 45 WaveOne Gold (25/.07), and 45 Twisted File Adaptive (25/.08) files were tested for cyclic fatigue at room temperature (20°C) in air and water and at body temperature (35°C) in water. All the instruments were rotated in artificial canals made of stainless steel with an inner diameter of 1.5 mm, 60° angle of curvature and a radius of curvature of 5 mm until fracture occurred; the time to fracture was recorded in seconds, using a digital chronometer. Mann-Whitney U test was used for the statistical analysis of data, with SPSS 21.0. Results. Cyclic fatigue resistance was significantly higher in all the groups in water at an ambient temperature of 20°C compared with air and water at temperatures of 20°C and 35°C, respectively (P<0.05). The intragroup analysis revealed that HyFlex EDM had the highest cyclic fatigue resistance, followed by Reciproc Blue, WaveOne Gold, and Twisted File Adaptive in both air and water at 20°C (P<0.05). HyFlex EDM exhibited the highest cyclic fatigue resistance in water at 35°C, whereas there was no significant difference between the other groups (P>0.05). Conclusion. Within the limitations of the present study, an increase in the ambient temperature significantly decreased the cyclic fatigue resistance of the tested NiTi files.

19.
J Contemp Dent Pract ; 20(6): 680-685, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-31358709

RESUMO

AIM: The aim of this study is to evaluate and compare the shaping ability of HyFlex™ EDM (HFEDM) and ProTaper Next (PTN) rotary instruments in curved root canals by using micro-computed tomography (micro-CT) imaging. MATERIALS AND METHODS: A total of 22 mandibular molar teeth having separate mesial canals with 20 to 30° curvatures were randomly divided into two groups and instrumented with HFEDM (OneFile) or PTN (X1 and X2). Pre- and post-instrumentation micro-CT scans were obtained. Mesiodistal canal transportation and centering ability were evaluated in four cross-sections (2, 4, 6, and 8 mm from apex). Changes in canal volume and surface area were measured for a 10-mm standardized area of interest. Kolmogorov-Smirnov and Shapiro-Wilk tests were used to assess the normality and homogeneity. Independent and paired t tests and one-way ANOVA were used to analyze data at the p < 0.05 level. RESULTS: Compared to PTN, HFEDM showed significantly less mesiodistal canal transportation and improved centering ability in cross-section L6 (p < 0.05). The instruments showed similar increases in volume and surface area of the canals, with minor insignificant differences. CONCLUSION: HFEDM and PTN files were safe to use in curved canals and showed similar shaping ability, while respecting the original anatomies. HFEDM OneFile performed better at the vicinity of the danger zone in terms of mesiodistal canal transportation and centering ability.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Dente Molar , Microtomografia por Raio-X
20.
Photobiomodul Photomed Laser Surg ; 37(8): 495-499, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31211638

RESUMO

Objective: The aim of this study was to compare the efficacy of HyFlex EDM (Coltene/Whaledent, Altstätten, Switzerland) and ProTaper Universal Retreatment Nickel-Titanium (NiTi) Systems [The ProTaper Universal Retreatment (PTR), Dentsply Maillefer, Ballaigues, Switzerland] in the removal of the root canal filling materials with or without laser activated irrigation. Materials and methods: The root canals of 60 human mandibular premolars were instrumented with K files up to size 35 at a working length; the step-back procedure was performed in 1 mm increments up to size 50. Next, the teeth were obturated using the lateral compaction technique with gutta-percha and resin-based sealer, and they were randomly divided into two groups (n = 30) according to the retreatment systems: PTR and HyFlex EDM NiTi rotary files. Then, each group was divided into two subgroups (n = 15), laser [photon-induced photo-acoustic streaming (PIPS); Fotona, Ljubljana, Slovenia] activated irrigation and conventional needle irrigation group. Following these procedures, the specimens were evaluated using micro-computed tomography. Results: There was no significant difference between the instrumentation systems regarding the cleaning efficacy (χ2 = 0.754; p = 0.86). Additionally, PIPS method did not have a significant effect on the removal of the filling material compared to conventional needle irrigation. Conclusions: Both instrumentation systems were effective in removing the filling material, but neither was able to remove the filling material completely. PIPS method did not show a significant additional effect regarding the removal of filling material.


Assuntos
Instrumentos Odontológicos , Técnicas Fotoacústicas/métodos , Materiais Restauradores do Canal Radicular/farmacologia , Obturação do Canal Radicular/instrumentação , Dente Pré-Molar , Humanos , Técnicas In Vitro , Teste de Materiais , Níquel , Retratamento , Irrigantes do Canal Radicular/farmacologia , Hipoclorito de Sódio/farmacologia , Titânio , Microtomografia por Raio-X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA