Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Clin Chem Lab Med ; 2024 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-39238208

RESUMO

OBJECTIVES: This study aimed to assess the validity of external quality assessment (EQA) laboratory results across various cultural and environmental contexts and to identify potential improvement areas. METHODS: The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Task Force on Global Laboratory Quality (TF-GLQ) conducted a 2-year study (2022 and 2023) in which EQA materials, related software and online training was provided by a commercial vendor to 100 laboratories in ten IFCC member society countries. The results were analysed on a monthly basis by the TF-GLQ, to show the number of submissions per country, tests per lab, acceptability rates, random failures and to get a measure of which analytes performed poorly. RESULTS: The EQA material was dispatched on a quarterly basis. Some countries had problems with customs releasing the material in a timely manner, resulting in laboratories not receiving them on time leading to no submission. We report here the results for the second year of the survey. The number of examinations varied between laboratories, ranging from seven to 84 analytes. Of the ten countries surveyed, six averaged greater than 90 % acceptable results over the whole 12-months cycle, one had unacceptable results for two of the nine months they returned results and the other four were considered to not perform to an acceptable standard. CONCLUSIONS: All 100 participating laboratories indicated satisfaction with the EQA survey and related services, including on-site training, and report handling. However, specimen receiving issues, suggest benefits in dispatching materials for a full 12-month cycle. Significant discrepancies in EQA performance indicate that four countries require long-term assistance, training and guidance. To ensure reliable patient results, promoting EQA in certain countries is essential to achieve the required level of quality.

2.
Clin Exp Nephrol ; 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39110345

RESUMO

BACKGROUND: Elevated serum alkaline phosphatase (ALP) levels are a risk factor for all-cause mortality in hemodialysis patients. Traditionally in Japan, ALP measurements were conducted using the JSCC method, which yields higher ALP measurement values than the IFCC method, mainly due to its increased sensitivity to intestinal ALP. METHODS: Serum total ALP levels before and after switching the assay method from JSCC to IFCC were compared among different blood types in 521 hemodialysis patients (Study 1). The association between ALP levels measured by the JSCC method and 7-year mortality was analyzed, including blood types and liver function parameters as covariates, in 510 hemodialysis patients (Study 2). RESULTS: ALP levels measured by the JSCC method were approximately three times higher than those measured by the IFCC method, with significant elevation in patients with blood types B and O compared to those with blood types A and AB. Similarly, ALP levels measured by the IFCC method were significantly higher in patients with blood types B and O compared to those with blood types A and AB (Study 1). The highest tertile of ALP levels showed a significantly increased risk of all-cause mortality, even after adjusting for patient background. However, this significance disappeared when serum liver function-related or inflammatory markers were included as covariates (Study 2). CONCLUSION: ALP levels measured by the JSCC method are associated with life prognosis, but caution should be exercised due to their elevation in patients with blood types B and O and in those with hepatic dysfunction or inflammation.

3.
Clin Chim Acta ; 555: 117800, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38309557

RESUMO

BACKGROUND: Carbohydrate deficient transferrin (CDT) is a biomarker for excessive alcohol consumption utilized in clinical and forensic medicine and workplace testing. Previously, many different analytical methods for CDT were used and the measurand varied considerably, making direct comparison of test results difficult. To end this confusion, the IFCC established a working group on CDT standardisation (WG-CDT) which completed its tasks in 2017. METHODS: This IFCC position paper by the WG-CDT summarizes state of the art information about the measurand and the analytical methods and gives concise recommendations for its utilization. RESULTS: The results achieved by the CDT standardisation process led to accuracy improvements in national external quality assessment schemes over the years. A brief review of ROC based comparison studies with the traditional biomarkers (GGT, MCV, ALT and AST) discusses the bias resulting from inadequate study populations. In large groups of the general population the superior diagnostic performance of CDT is confirmed. CONCLUSION: The relationship between alcohol intake versus resulting CDT is discussed as well as the cutoff and measurement uncertainty. Concerning the application in practice, potential pitfalls are considered and recommendations handling both analytical and preanalytical caveats are given. Finally, some examples of serious misunderstandings in publications about CDT are addressed.


Assuntos
Consumo de Bebidas Alcoólicas , Humanos , Padrões de Referência , Biomarcadores
4.
J Clin Lab Anal ; 37(13-14): e24955, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37571860

RESUMO

BACKGROUND: This study aimed to assess the commutability of frozen pooled human serum (PHS), high concentration of Immunoglobulin M (IgM) pure diluted materials (HPDM), commercialized pure materials (CPM), and dilutions of ERM-DA470k/IFCC in IgM detection using the CLSI and IFCC approaches, to support standardization or harmonization of IgM measurement. METHODS: Twenty-four serum samples, relevant reference materials (PHS, HPDM, CPM), and different ERM-DA470k/IFCC dilutions were analyzed in triplicate using six routine methods. The commutability of the relevant reference materials was carried out following CLSI EP30-A and IFCC bias analysis. RESULTS: According to the CLSI approach, low, medium, and high concentrations of PHS, HPDM, and CPM were commutable on 10, 13, 15, 13, and 8 of 15 assay combinations, respectively. Using the IFCC approach, low, medium, and high concentrations of PHS, HPDM, and CPM were commutable on 10, 11, 9, 15, and 10 of 15 assay combinations, respectively. The ERM-DA470k/IFCC dilutions with D-PBS and RPMI-1640 Medium were commutable on 13 of 15 assay combinations according to CLSI and were commutable on all 15 assay combinations using IFCC approach. CONCLUSIONS: High concentration of PHS were commutable on all six detection systems using the CLSI approach. Low and medium concentration of PHS showed unsatisfied commutability. HPDM, not CPM have good commutability, has the potential to become reference materials. ERM-DA470k/IFCC diluted with different medium showed different commutability.


Assuntos
Soro , Humanos , Padrões de Referência , Testes de Coagulação Sanguínea , Imunoglobulina M , Técnicas de Diluição do Indicador
5.
Clin Chem Lab Med ; 61(12): 2094-2101, 2023 11 27.
Artigo em Inglês | MEDLINE | ID: mdl-37327359

RESUMO

OBJECTIVES: The trueness and precision of clinical laboratory results are ensured through total quality management systems (TQM), which primarily include internal quality control (IQC) practices. However, quality practices vary globally. To understand the current global state of IQC practice and IQC management in relation to TQM the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Task Force on Global Laboratory Quality (TF-GLQ) conducted a survey of IFCC member countries on IQC practices and management. METHODS: The survey included 16 questions regarding IQC and laboratory TQM practices and was distributed to IFCC full and affiliate member countries (n=110). A total of 46 (41.8 %) responses were received from all regions except North America. RESULTS: Of the responding countries, 78.3 % (n=36) had legislative regulations or accreditation requirements governing medical laboratory quality standards. However, implementation was not mandatory in 46.7 % (n=21) of responding countries. IQC practices varied considerably with 57.1 % (n=28) of respondents indicating that they run 2 levels of IQC, 66.7 % (n=24) indicating they run IQC every 24 h and 66.7 % (n=28) using assay manufacturer IQC material sources. Only 29.3 % (n=12) of respondents indicated that every medical laboratory in their country has written IQC policies and procedures. By contrast, 97.6 % (n=40) of responding countries indicated they take corrective action and result remediation in the event of IQC failure. CONCLUSIONS: The variability in TQM and IQC practices highlights the need for more formal programs and education to standardize and improve TQM in medical laboratories.


Assuntos
Laboratórios , Gestão da Qualidade Total , Humanos , Controle de Qualidade , Inquéritos e Questionários
6.
J Mass Spectrom Adv Clin Lab ; 28: 20-26, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36814695

RESUMO

ß-thalassemia is a quantitative hemoglobin (Hb) disorder resulting in reduced production of Hb A and increased levels of Hb A2. Diagnosis of ß-thalassemia can be problematic when combined with other structural Hb variants, so that the separation approaches in routine clinical centers are not sufficiently decisive to obtain accurate results. Here, we separate the intact Hb subunits by high-performance liquid chromatography, followed by top-down tandem mass spectrometry of intact subunits to distinguish Hb variants. Proton transfer reaction-parallel ion parking (PTR-PIP), in which a radical anion removes protons from multiply charged precursor ions and produces charge-reduced ions spanning a limited m/z range, was used to increase the signal-to-noise ratio of the subunits of interest. We demonstrate that the δ/ß ratio can act as a biomarker to identify ß-thalassemia in normal electrospray ionization MS1 and PTR-PIP MS1. The application of PTR-PIP significantly increases the sensitivity and specificity of the HPLC-MS method to identify δ/ß ratio as a thalassemia biomarker.

7.
Clin Chem Lab Med ; 61(8): 1404-1410, 2023 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-36779362

RESUMO

OBJECTIVES: Clinical laboratory results are required for critical medical decisions, underscoring the importance of quality results. As part of total quality management, external quality assessment (EQA) is a vital component to ensure laboratory accuracy. The goal of this survey was to evaluate the current status of global laboratory quality systems and assess the need for implementation, expansion, or harmonization of EQA programs (EQAP) for Clinical Chemistry and Laboratory Medicine. METHODS: The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Task Force on Global Laboratory Quality (TF-GLQ) conducted a survey of IFCC full and affiliate members (n=110) on laboratory quality practice. A total of 41 (37.3%) countries representing all IFCC regions except North America provided responses about EQA availability and practices. RESULTS: All 41 countries perform EQA, 38 reported that their laboratories had EQA policies and procedures, and 39 further act/evaluate unacceptable EQA results. 39 countries indicated they have international and/or national EQAP and 30 use alternative performance assessments. EQA frequency varied among countries. Generally, an EQAP provided the EQA materials (40/41) with four countries indicating that they did not have an EQAP in their country. CONCLUSIONS: Globally, most laboratories participate in an EQAP and have defined quality procedures for EQA. There remain gaps in EQA material availability and implementation of EQA as a part of a total laboratory quality system. This survey highlights the need for education, training, and harmonization and will guide efforts of the IFCC TF-GLQ in identifying areas for enhancing global laboratory quality practices.


Assuntos
Química Clínica , Laboratórios , Humanos , Inquéritos e Questionários , Gestão da Qualidade Total , Garantia da Qualidade dos Cuidados de Saúde
8.
Clin Chem Lab Med ; 61(4): 666-673, 2023 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-36436024

RESUMO

Clinical laboratories play a vital role in the healthcare system. Objective medical data provided by clinical laboratories supports approximately 60-70% of clinical decisions, however, evidence supporting this claim is poorly documented and laboratories still lack visibility, despite their indisputable impact on patient care and public health. The International Federation for Clinical Chemistry and Laboratory Medicine (IFCC) Task Force on Outcome Studies in Laboratory Medicine (TF-OSLM) was recently developed to support directed research evaluating the role of laboratory medicine on clinical outcomes. Establishing and documenting this evidence is key to enhance visibility of the field in the eye of the public and other healthcare professionals together with optimizing patient outcomes and health care system operations. In this review, we discuss four areas that exemplify the contribution of laboratory medicine directly to patient care. This includes high-sensitivity cardiac troponin (hs-cTn) and N-terminal pro-B-type natriuretic peptide/B-type natriuretic peptides (NT-proBNP/BNP) for the diagnosis and prognosis of myocardial infarction and heart failure, respectively, and procalcitonin for the management of sepsis and antibiotic stewardship. Emerging markers of traumatic brain injury and the role of laboratory medicine in the fight against the COVID-19 pandemic are discussed along with an introduction to plans of IFCC TF-OSLM.


Assuntos
COVID-19 , Laboratórios , Humanos , Saúde Pública , Pandemias , Prognóstico , Peptídeo Natriurético Encefálico , Assistência ao Paciente , Fragmentos de Peptídeos , Biomarcadores
9.
J Vet Med Sci ; 85(2): 232-235, 2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36543184

RESUMO

The approved Japanese measurement method of circulating alkaline phosphatase (ALP) has changed from that of the Japan Society of Clinical Chemistry (JSCC) to that of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). We measured the serum levels of total ALP (t-ALP) and those of the isoenzymes ALP2 and ALP3 in 50 Asian elephant (Elephas maximus) specimens using both methods. The activities determined by the IFCC method were roughly one-third lower than those determined by the JSCC method. We present conversion formulae. Our results enable comparisons of historical and current data on serum ALP activities in endangered, zoo-managed Asian elephants.


Assuntos
Elefantes , Isoenzimas , Animais , Fosfatase Alcalina , Química Clínica , Corantes , Animais de Zoológico
10.
Clin Chem Lab Med ; 60(9): 1426-1439, 2022 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-35786502

RESUMO

OBJECTVIES: This study is aimed at establishing reference intervals (RIs) of 40 chemistry and immunochemistry analytes for Ghanaian adults based on internationally harmonized protocol by IFCC Committee on Reference Intervals and Decision Limits (C-RIDL). METHODS: A total of 501 healthy volunteers aged ≥18 years were recruited from the northern and southern regions of Ghana. Blood samples were analyzed with Beckman-Coulter AU480 and Centaur-XP/Siemen auto-analyzers. Sources of variations of reference values (RVs) were evaluated by multiple regression analysis (MRA). The need for partitioning RVs by sex and age was guided by the SD ratio (SDR). The RI for each analyte was derived using parametric method with application of the latent abnormal values exclusion (LAVE) method. RESULTS: Using SDR≥0.4 as threshold, RVs were partitioned by sex for most enzymes, creatinine, uric acid (UA), bilirubin, immunoglobulin-M. MRA revealed age and body mass index (BMI) as major source of variations of many analytes. LAVE lowered the upper limits of RIs for alanine/aspartate aminotransferase, γ-glutamyl transaminase and lipids. Exclusion of individuals with BMI≥30 further lowered the RIs for lipids and CRP. After standardization based on value-assigned serum panel provided by C-RIDL, Ghanaian RIs were found higher for creatine kinase, amylase, and lower for albumin and urea compared to other collaborating countries. CONCLUSIONS: The LAVE effect on many clinical chemistry RIs supports the need for the secondary exclusion for reliable derivation of RIs. The differences in Ghanaian RIs compared to other countries underscore the importance of country specific-RIs for improved clinical decision making.


Assuntos
Química Clínica , Lipídeos , Adolescente , Adulto , Fatores Etários , Alanina Transaminase , Gana , Humanos , Valores de Referência
11.
Saudi J Biol Sci ; 29(5): 3626-3634, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35844382

RESUMO

Herein, the impact of the halloysite nanotubes to suppress the side effects of Asparaginase (ANase) cellular proliferation was investigated. Methods: A total of 100 adult male mice was employed. These mice were divided into four equal groups; Group 1 (control), Group 2 (ESC group) of a single dose of 0.15 ml Ehrlich cells (2 × 106) intraperitoneal infusion(IP), Group 3 (ESC + ANase group) received six doses equal treatments of Intratumoral (IT) 0.07 ml Aspragnase (7 mg/kg) over two weeks. For two weeks, Group 4 (ESC + ASNase + HNTs) received an IT administration of 0.07 ml Asparaginase stocked on Halloysite nanotubes (HNTs) (30 mg/kg) three times per week. A blood specimen was collected, and the liver was removed to be investigated histologically. Results: TEM measurements for the Halloysite nanoclay showed their tubular cylindrical shape with a mean diameter of 50 nm and an average length of 1 µm, whereas The X-ray diffraction pattern of the Halloysite nanoclay showed their characteristic peaks. ESC increases the serum levels of aspartate aminotransferase, alanine aminotransferase, alkaline phosphatase, and bilirubin than control and other groups, even as albumin and total protein were decreasing. After using Halloysite Nanotube, the rates of these variables were enhanced up to 75%. The hepatocytes histological studies showed protection against Ehrlich Solid carcinoma-induced degenerative, necrotic, and inflammatory changes up to 70%. In conclusion, halloysite nanotubes have demonstrated effective removal of Ehrlich solid carcinoma in mice using an ASNase delivery system. It promoted the ASNase to inhibit the adverse effect of ANase's on the liver and remove the tumour cells.

12.
J Mass Spectrom Adv Clin Lab ; 24: 22-30, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35252947

RESUMO

BACKGROUND: Indirect reference intervals require robust statistical approaches to separate the pathological and healthy values. This can be achieved with a data pipeline created in R, a freely available statistical programming language. METHODS: A data pipeline was created to ingest, partition, normalize, remove outliers, and identify reference intervals for testosterone (Testo; n  = 7,207) and aspartate aminotransferase (AST; n  = 5,882) using data sets from NHANES. RESULTS: The estimates for AST and Testo determined by this pipeline approximated current RIs. Care should be taken when using this pipeline as there are limitations that depend on the pathology of the analyte and the data set being used for RI estimation. CONCLUSIONS: R can be used to create a robust statistical reference interval pipeline.

13.
Clin Chim Acta ; 519: 183-186, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33933427

RESUMO

Measurements of thyroid stimulating hormone (TSH) and free thyroxine (fT4) are critical for the early detection of thyroid diseases and for monitoring treatment. The IFCC Committee for Standardization of Thyroid Function Tests (C-STFT) established reference systems for TSH harmonization and FT4 standardization, and is now working national partners on implementing these reference systems. These implementation activities include the maintenance of the reference systems, their use to standardize and harmonize assays, and educational activities to inform stakeholders about anticipated changes in measurement values as a result of standardization and harmonization. The IFCC C-STFT formed a network of reference laboratories for FT4 and is creating a new harmonization panel for TSH. The U.S. Centers for Disease Control and Prevention is a member of the reference laboratory network and is launching a formal standardization program for FT4. In Japan, national organizations successfully implemented TSH harmonization and established harmonized reference intervals for TSH. The C-STFT made available on its website research findings about potential concerns, communication needs and benefits of FT4 standardization and is assisting local organizations with communicating changes related to these standardization and harmonization efforts. Implementation of fT4 standardization and TSH harmonization is a complex, continuous task that requires collaboration with IVD manufacturers, laboratories, physicians and health care providers. C-STFT is working successfully with national organizations and local groups on improving FT4 and TSH measurements.


Assuntos
Doenças da Glândula Tireoide , Testes de Função Tireóidea , Humanos , Japão , Valores de Referência , Tireotropina , Tiroxina
14.
Pract Lab Med ; 25: e00218, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33898688

RESUMO

OBJECTIVES: Measurement of lipoprotein(a) [Lp(a)] is used in risk assessment of atherosclerotic cardiovascular disease (ASCVD). The aim of the current study was to evaluate performance characteristic of five different Lp(a) assays using the cobas c501 (Roche Diagnostics) analyzer. DESIGN AND METHODS: Lp(a) was measured using five Lp(a) assays (Diazyme, Kamiya, MedTest, Randox, and Roche) configured to mg/dL units. Assays from Diazyme and Kamiya were also configured using nmol/L units in separate experiments. Studies included sensitivity, imprecision, linearity, method comparison, and evaluation of healthy subjects. Imprecision (intra-day, 20 replicates; inter-day, duplicates twice daily for five days) and linearity were evaluated using patient pools. Linearity assessed a minimum of five patient splits spanning the analytical measurement range (AMR). Method comparison used 80 residual serum samples. Specimens from 120 self-reported healthy subjects (61 females / 59 males) were also tested. Method comparison for two assays in nmol/L units was conducted using 96 residual serum samples. RESULTS: Assay sensitivities met all manufacturer claims. Imprecision studies demonstrated %CVs ranging from 2.5 to 5.2% for the low pool (average concentration from 7.3 to 12.4 â€‹mg/dL); high pool %CVs ranged from 0.8 to 3.0% (average concentrations from 31.5-50.2 â€‹mg/dL). Linearity was confirmed for all assays. Variation in accuracy was observed when comparing results to an all method average. Lp(a) results were higher in females versus males in self-reported healthy subjects. CONCLUSIONS: All assays performed according to manufacturer described performance characteristics, although differences were observed across Lp(a) assays tested when compared to an all method average.

16.
Pract Lab Med ; 17: e00147, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31799362

RESUMO

OBJECTIVES: The level of glycated hemoglobin A (HbA1C) in blood is the preferred marker for diabetes monitoring and treatment. Here, we evaluate the analytical performance of the Roche Diagnostics Cobas c 513, a stand-alone HbA1C immunoassay analyzer. DESIGN AND METHODS: Performance was assessed with regards to imprecision, accuracy, linearity, method comparison against the Roche Cobas Integra 800 CTS, specimen stability, interference from common hemoglobin variants and hemoglobin F, and throughput. RESULTS: Within-run and between-run precisions were 0.5-0.7 and 0.8-1.3%CV, respectively. An average bias of -1.6% to proficiency survey samples was observed. The c 513 correlated well with the Integra (slope = 0.94, y-intercept = 0.50, and correlation coefficient = 0.998). The effect of hemoglobin variants on this assay was negligible while specimens containing ≥10% HbF demonstrated a negative bias. The c 513 instrument can process up to 340 samples per hour. CONCLUSIONS: The c 513 is a precise, accurate, automated high throughput analyzer for measuring HbA1C in large laboratories.

18.
Clin Chim Acta ; 492: 26-28, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30711523

RESUMO

BACKGROUND: The detection of an increase and/or decrease of cardiac troponin (cTnI) values, with at least one value above the 99th percentile of the upper reference limit (URL) have a central role in acute myocardial infarction (AMI) diagnosis. The employment of sex specific 99th percentile URLs and High-sensitivity (Hs) assays are recommended. We assessed sex specific 99th percentile URL for Access Hs-cTnI and AccuTnI3+ (Beckman Coulter) using European donor reference population following recent International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) recommendations. METHODS: 300 males and 300 females plasma samples were collected. Both chemiluminescent immunoenzymatic assays were performed on UniCel DxI 800 platform (Beckman Coulter). RESULTS: For Access hsTnI, the observed sex-specific 99th percentile URLs were 5.5 (90% CI: 4.4-7.6) for females and 13.9 ng/L (90% CI: 7.4-17.4) for males. For AccuTnI+3 we could not establish them because the assay couldn't report detectable values of troponin for most of the analyzed samples. CONCLUSION: The sex-specific 99th percentile URLs established for Access hsTnI assay were significantly lower than those declared by the manufacturer caused by the different choice of population selection, age groups and sample types: for those reasons, we maintain the 99th URLs provided by manufacturer.


Assuntos
Análise Química do Sangue/normas , Agências Internacionais , Troponina I/sangue , Feminino , Humanos , Limite de Detecção , Masculino , Valores de Referência
19.
EJIFCC ; 29(4): 253-258, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30574034

RESUMO

The role of Proficiency Testing schemes (PT) or External Quality Control programs (EQA), involves the use of inter-laboratory comparisons for the determination of laboratory performance. EQA-PT schemes are of primordial importance to the analytical quality, standardization of methods and harmonization of the results. Laboratories are familiar with EQA-PT schemes as they are a prerequisite for their accreditation according to the ISO/IEC 15189 standard. The IFCC Committee on Proficiency Testing (C-PT) conducted a survey among the colleagues of the Mediterranean countries in order to evaluate the status of the EQA-PT providers in the region, their acceptance among laboratories, and possible issues in their implementation. The survey was organized electronically and we received 59 replies from colleagues (IFCC National Representatives and affiliated EQA-PT providers), from 17 of the 23 countries (74%) of the Mediterranean area. We concluded that there is a broad difference in the application of the rules of External Quality Control programs or Proficiency Testing schemes, among the Laboratories in the Mediterranean countries. Moreover, as the Accreditation of the Laboratories is not mandatory in the majority of these countries, there is no valid reason for participation in EQA-PT schemes.

20.
Clin Chem Lab Med ; 57(2): 288-295, 2018 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-30044761

RESUMO

Background Diabetes mellitus is a major global issue and high quality testing is essential for the diagnosis and treatment of the disease. The IFCC Committee for the Education in the Utility of Biomarkers in Diabetes (C-EUBD) plays a global role in improving knowledge and understanding around diabetes testing. This paper describes a multi-stakeholder approach, to improving diagnostic and therapeutic testing for diabetes, using a multicentre study in China as an example of the global impact of the group. Methods Educational workshops were developed to support the scientific aims of the study in which 30 centres around China received identical, fresh frozen whole blood samples with values assigned using IFCC secondary reference methods and undertook precision (EP-5) and trueness studies. Performance was assessed using sigma metrics. Results A successful multi-stakeholder group was developed and sustained throughout the study through several educational workshops, which enabled the formation of a long-term collaboration with key opinion leaders and policy makers in China. All 30 centres showed good performance with within and between laboratory coefficient of variations (CVs) below 3% in SI units at both low and high haemoglobin A1c (HbA1c) levels. All individual laboratories met the criteria of a sigma of two or more at a total allowable error (TAE) of 5 mmol/mol (0.46% NGSP). Conclusions The study led to a successful multi-partner approach to improving diabetes testing in China. All centres involved in the study meeting the published IFCC quality criteria, paving the way for future clinical trials and an expanded role for HbA1c testing across the country.


Assuntos
Química Clínica , Diabetes Mellitus/sangue , Hemoglobinas Glicadas/análise , Controle de Qualidade , China , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA