Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 139
Filtrar
1.
NMR Biomed ; : e5234, 2024 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-39097977

RESUMO

Understanding the effects of white matter (WM) axon fibre microstructure on T1 relaxation is important for neuroimaging. Here, we have studied the interrelationship between T1 and axon fibre configurations at 3T and 7T. T1 and S0 (=signal intensity at zero TI) were computed from MP2RAGE images acquired with six inversion recovery times. Multishell diffusion MRI images were analysed for fractional anisotropy (FA); MD; V1; the volume fractions for the first (f1), second (f2) and third (f3) fibre configuration; and fibre density cross-section images for the first (fdc1), second (fdc2) and third (fdc3) fibres. T1 values were plotted as a function of FA, f1, f2, f3, fdc1, fdc2 and fdc3 to examine interrelationships between the longitudinal relaxation and the diffusion MRI microstructural measures. T1 values decreased with increasing FA, f1 and f2 in a nonlinear fashion. At low FA values (from 0.2 to 0.4), a steep shortening of T1 was followed by a shallow shortening by 6%-10% at both fields. The steep shortening was associated with decreasing S0 and MD. T1 also decreased with increasing fdc1 values in a nonlinear fashion. Instead, only a small T1 change as a function of either f3 or fdc3 was observed. In WM areas selected by fdc1 only masks, T1 was shorter than in those with fdc2/fdc3. In WM areas with high single fibre populations, as delineated by f1/fdc1 masks, T1 was shorter than in tissue with high complex fibre configurations, as segmented by f2/fdc2 or f3/fdc3 masks. T1 differences between these WM areas are attributable to combined effects by T1 anisotropy and lowered FA. The current data show strong interrelationships between T1, axon fibre configuration and orientation in healthy WM. It is concluded that diffusion MRI microstructural measures are essential in the effort to interpret quantitative T1 images in terms of tissue state in health and disease.

2.
Insights Imaging ; 15(1): 200, 2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39120775

RESUMO

A knowledge of the complex phenomena that regulate T1 signal on Magnetic Resonance Imaging is essential in clinical practice for a more effective characterization of pathological processes. The authors review the physical basis of T1 Relaxation Time and the fundamental aspects of physics and chemistry that can influence this parameter. The main substances (water, fat, macromolecules, methemoglobin, melanin, Gadolinium, calcium) that influence T1 and the different MRI acquisition techniques that can be applied to enhance their presence in diagnostic images are then evaluated. An extensive case illustration of the different phenomena and techniques in the areas of CNS, abdomino-pelvic, and osteoarticular pathology is also proposed. CRITICAL RELEVANCE STATEMENT: T1 relaxation time is strongly influenced by numerous factors related to tissue characteristics and the presence in the context of the lesions of some specific substances. An examination of these phenomena with extensive MRI exemplification is reported. KEY POINTS: The purpose of the paper is to illustrate the chemical-physical basis of T1 Relaxation Time. MRI methods in accordance with the various clinical indications are listed. Several examples of clinical application in abdominopelvic and CNS pathology are reported.

3.
Chem Pharm Bull (Tokyo) ; 72(7): 676-680, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39019598

RESUMO

The purpose of this study was to continuously monitor the pseudopolymorphic transition from anhydrate to monohydrate by measuring the NMR relaxation using time-domain NMR (TD-NMR). Taking advantage of the simplicity of the low-field NMR instrument configuration, which is an advantage of TD-NMR, the NMR instrument was connected to a humidity controller to monitor the pseudopolymorphic transition. First, ezetimibe (EZT) monohydrate was prepared from its anhydrate using a saturated salt solution method, and T1 relaxation of EZT monohydrate and anhydrate was measured without a humidity controller. The T1 relaxation results confirmed that EZT anhydrate and monohydrate could be distinguished using T1 relaxation measurement. Next, continuous monitoring was conducted by TD-NMR and connected to a humidity controller. Anhydrous EZT was placed in an NMR glass tube and the T1 relaxation measurement was repeated while maintaining the humidity on the side entering the NMR tube at 80% relative humidity. The T1 relaxation became gradually faster from the initial to middle monitoring phases. The final T1 relaxation was then recovered fully and these T1 relaxation times were the same as the T1 relaxation of EZT monohydrate. This study successfully monitored the pseudopolymorphic transition from EZT anhydrate to monohydrate via NMR relaxation.


Assuntos
Ezetimiba , Espectroscopia de Ressonância Magnética , Ezetimiba/química , Estrutura Molecular
4.
Abdom Radiol (NY) ; 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38900324

RESUMO

PURPOSE: To non-invasively quantify pancreatic fibrosis and grade severity of chronic pancreatitis (CP) on dual-energy CT (DECT) and multiparametric MRI (mpMRI). METHODS: We included 72 patients (mean age:30years; 59 men) with suspected or confirmed CP from December 2019 to December 2021 graded as equivocal(n = 20), mild(n = 18), and moderate-marked(n = 34) using composite imaging and endoscopic ultrasound criteria. Study patients underwent multiphasic DECT and mpMRI of the abdomen. Normalized iodine concentration(NIC) and fat fraction(FF) on 6-minute delayed DECT, and T1 relaxation time(T1Rt), extracellular volume fraction(ECVf), intravoxel incoherent motion-based perfusion fraction(PF), and magnetization transfer ratio(MTR) on mpMRI of pancreas were compared. 20 renal donors(for DECT) and 20 patients with renal mass(for mpMRI) served as controls. RESULTS: NIC of pancreas in controls and progressive grades of CP were 0.24 ± 0.05, 0.80 ± 0.18, 1.06 ± 0.23, 1.40 ± 0.36, FF were 9.28 ± 5.89, 14.19 ± 5.29, 17.31 ± 5.99, 29.32 ± 12.22, T1Rt were 590.11 ± 61.13, 801.93 ± 211.01, 1006.79 ± 352.18, 1388.01 ± 312.23ms, ECVf were 0.07 ± 0.03, 0.30 ± 0.12, 0.41 ± 0.12, 0.53 ± 0.13, PF were 0.38 ± 0.04, 0.28 ± 0.07, 0.25 ± 0.09, 0.21 ± 0.05 and MTR were 0.12 ± 0.03, 0.15 ± 0.06, 0.21 ± 0.07, 0.26 ± 0.06, respectively. There were significant differences for all quantitative parameters between controls and mild CP; for NIC, PF, and ECVf between controls and progressive CP grades (p < 0.05). Area under curve for NIC, FF, T1Rt, ECVf, PF, and MTR in differentiating controls and mild CP were 1.00, 0.86, 0.95, 1.00, 0.90 and 0.84 respectively and for NIC, FF, ECVf and PF in differentiating controls and equivocal CP were 1.00, 0.76, 0.95 and 0.92 respectively. CONCLUSION: DECT and mpMRI were useful in quantifying pancreatic fibrosis and grading the severity of CP. NIC was the most accurate marker.

5.
J Cardiovasc Magn Reson ; 26(2): 101046, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38810732

RESUMO

BACKGROUND: Three-dimensional (3D) contrast-enhanced magnetic resonance angiography (CEMRA) is routinely used for vascular evaluation. With existing techniques for CEMRA, diagnostic image quality is only obtained during the first pass of the contrast agent or shortly thereafter, whereas angiographic quality tends to be poor when imaging is delayed to the equilibrium phase. We hypothesized that prolonged blood pool contrast enhancement could be obtained by imaging with a balanced T1 relaxation-enhanced steady-state (bT1RESS) pulse sequence, which combines 3D balanced steady-state free precession (bSSFP) with a saturation recovery magnetization preparation to impart T1 weighting and suppress background tissues. An electrocardiographic-gated, two-dimensional-accelerated version with isotropic 1.1-mm spatial resolution was evaluated for breath-hold equilibrium phase CEMRA of the thoracic aorta and heart. METHODS: The study was approved by the institutional review board. Twenty-one subjects were imaged using unenhanced 3D bSSFP, time-resolved CEMRA, first-pass gated CEMRA, followed by early and late equilibrium phase gated CEMRA and bT1RESS. Nine additional subjects were imaged using equilibrium phase 3D bSSFP and bT1RESS. Images were evaluated for image quality, aortic root sharpness, and visualization of the coronary artery origins, as well as using standard quantitative measures. RESULTS: Equilibrium phase bT1RESS provided better image quality, aortic root sharpness, and coronary artery origin visualization than gated CEMRA (P < 0.05), and improved image quality and aortic root sharpness versus unenhanced 3D bSSFP (P < 0.05). It provided significantly larger apparent signal-to-noise and apparent contrast-to-noise ratio values than gated CEMRA and unenhanced 3D bSSFP (P < 0.05) and provided ninefold better fluid suppression than equilibrium phase 3D bSSFP. Aortic diameter and main pulmonary artery diameter measurements obtained with bT1RESS and first-pass gated CEMRA strongly correlated (P < 0.05). CONCLUSIONS: We found that using bT1RESS greatly prolongs the useful duration of blood pool contrast enhancement while improving angiographic image quality compared with standard CEMRA techniques. Although further study is needed, potential advantages for vascular imaging include eliminating the current requirement for first-pass imaging along with better reliability and accuracy for a wide range of cardiovascular applications.

6.
NMR Biomed ; 37(9): e5152, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38565525

RESUMO

Relaxation correction is an integral step in quantifying brain metabolite concentrations measured by in vivo magnetic resonance spectroscopy (MRS). While most quantification routines assume constant T1 relaxation across age, it is possible that aging alters T1 relaxation rates, as is seen for T2 relaxation. Here, we investigate the age dependence of metabolite T1 relaxation times at 3 T in both gray- and white-matter-rich voxels using publicly available metabolite and metabolite-nulled (single inversion recovery TI = 600 ms) spectra acquired at 3 T using Point RESolved Spectroscopy (PRESS) localization. Data were acquired from voxels in the posterior cingulate cortex (PCC) and centrum semiovale (CSO) in 102 healthy volunteers across 5 decades of life (aged 20-69 years). All spectra were analyzed in Osprey v.2.4.0. To estimate T1 relaxation times for total N-acetyl aspartate at 2.0 ppm (tNAA2.0) and total creatine at 3.0 ppm (tCr3.0), the ratio of modeled metabolite residual amplitudes in the metabolite-nulled spectrum to the full metabolite signal was calculated using the single-inversion-recovery signal equation. Correlations between T1 and subject age were evaluated. Spearman correlations revealed that estimated T1 relaxation times of tNAA2.0 (rs = -0.27; p < 0.006) and tCr3.0 (rs = -0.40; p < 0.001) decreased significantly with age in white-matter-rich CSO, and less steeply for tNAA2.0 (rs = -0.228; p = 0.005) and (not significantly for) tCr3.0 (rs = -0.13; p = 0.196) in graymatter-rich PCC. The analysis harnessed a large publicly available cross-sectional dataset to test an important hypothesis, that metabolite T1 relaxation times change with age. This preliminary study stresses the importance of further work to measure age-normed metabolite T1 relaxation times for accurate quantification of metabolite levels in studies of aging.


Assuntos
Espectroscopia de Ressonância Magnética , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Masculino , Feminino , Adulto Jovem , Envelhecimento/metabolismo , Envelhecimento/fisiologia , Longevidade , Encéfalo/metabolismo , Encéfalo/diagnóstico por imagem
7.
Mult Scler Relat Disord ; 86: 105520, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38582026

RESUMO

BACKGROUND: Previous studies have shown that thalamic and hippocampal neurodegeneration is associated with clinical decline in Multiple Sclerosis (MS). However, contributions of the specific thalamic nuclei and hippocampal subfields require further examination. OBJECTIVE: Using 7 Tesla (7T) magnetic resonance imaging (MRI), we investigated the cross-sectional associations between functionally grouped thalamic nuclei and hippocampal subfields volumes and T1 relaxation times (T1-RT) and subsequent clinical outcomes in MS. METHODS: High-resolution T1-weighted and T2-weighted images were acquired at 7T (n=31), preprocessed, and segmented using the Thalamus Optimized Multi Atlas Segmentation (THOMAS, for thalamic nuclei) and the Automatic Segmentation of Hippocampal Subfields (ASHS, for hippocampal subfields) packages. We calculated Pearson correlations between hippocampal subfields and thalamic nuclei volumes and T1-RT and subsequent multi-modal rater-determined and patient-reported clinical outcomes (∼2.5 years after imaging acquisition), correcting for confounders and multiple tests. RESULTS: Smaller volume bilaterally in the anterior thalamus region correlated with worse performance in gait function, as measured by the Patient Determined Disease Steps (PDDS). Additionally, larger volume in most functional groups of thalamic nuclei correlated with better visual information processing and cognitive function, as measured by the Symbol Digit Modalities Test (SDMT). In bilateral medial and left posterior thalamic regions, there was an inverse association between volumes and T1-RT, potentially indicating higher tissue degeneration in these regions. We also observed marginal associations between the right hippocampal subfields (both volumes and T1-RT) and subsequent clinical outcomes, though they did not survive correction for multiple testing. CONCLUSION: Ultrahigh field MRI identified markers of structural damage in the thalamic nuclei associated with subsequently worse clinical outcomes in individuals with MS. Longitudinal studies will enable better understanding of the role of microstructural integrity in these brain regions in influencing MS outcomes.


Assuntos
Hipocampo , Imageamento por Ressonância Magnética , Esclerose Múltipla , Núcleos Talâmicos , Humanos , Hipocampo/diagnóstico por imagem , Hipocampo/patologia , Masculino , Feminino , Adulto , Núcleos Talâmicos/diagnóstico por imagem , Núcleos Talâmicos/patologia , Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla/patologia , Pessoa de Meia-Idade , Estudos Transversais
8.
Magn Reson Med ; 92(1): 57-68, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38308151

RESUMO

PURPOSE: To investigate the effect of inhaled oxygen level on dynamic glucose enhanced (DGE) MRI in mouse brain tissue and CSF at 3 T. METHODS: DGE data of brain tissue and CSF from mice under normoxia or hyperoxia were acquired in independent and interleaved experiments using on-resonance variable delay multi-pulse (onVDMP) MRI. A bolus of 0.15 mL filtered 50% D-glucose was injected through the tail vein over 1 min during DGE acquisition. MRS was acquired before and after DGE experiments to confirm the presence of D-glucose. RESULTS: A significantly higher DGE effect under normoxia than under hyperoxia was observed in brain tissue (p = 0.0001 and p = 0.0002 for independent and interleaved experiments, respectively), but not in CSF (p > 0.3). This difference is attributed to the increased baseline MR tissue signal under hyperoxia induced by a shortened T1 and an increased BOLD effect. When switching from hyperoxia to normoxia without glucose injection, a signal change of ˜3.0% was found in brain tissue and a signal change of ˜1.5% was found in CSF. CONCLUSIONS: DGE signal was significantly lower under hyperoxia than that under normoxia in brain tissue, but not in CSF. The reason is that DGE effect size of brain tissue is affected by the baseline signal, which could be influenced by T1 change and BOLD effect. Therefore, DGE experiments in which the oxygenation level is changed from baseline need to be interpreted carefully.


Assuntos
Encéfalo , Glucose , Hiperóxia , Imageamento por Ressonância Magnética , Oxigênio , Animais , Camundongos , Imageamento por Ressonância Magnética/métodos , Glucose/metabolismo , Oxigênio/metabolismo , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Hiperóxia/diagnóstico por imagem , Administração por Inalação , Masculino , Camundongos Endogâmicos C57BL
9.
Magn Reson Med ; 92(1): 158-172, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38411277

RESUMO

PURPOSE: Abnormalities in cerebral veins are a common finding in many neurological diseases, yet there is a scarcity of MRI techniques to assess venous hemodynamic function. The present study aims to develop a noncontrast technique to measure a novel blood flow circulatory measure, venous transit time (VTT), which denotes the time it takes for water to travel from capillary to major veins. METHODS: The proposed sequence, venous transit time imaging by changes in T1 relaxation (VICTR), is based on the notion that as water molecules transition from the tissue into the veins, they undergo a change in T1 relaxation time. The validity of the measured VTT was tested by studying the VTT along the anatomically known flow trajectory of venous vessels as well as using a physiological vasoconstrictive challenge of caffeine ingestion. Finally, we compared the VTT measured with VICTR MRI to a bolus-tracking method using gadolinium-based contrast agent. RESULTS: VTT was measured to be 3116.3 ± 326.0 ms in the posterior superior sagittal sinus (SSS), which was significantly longer than 2865.0 ± 390.8 ms at the anterior superior sagittal sinus (p = 0.004). The test-retest assessment showed an interclass correlation coefficient of 0.964. VTT was significantly increased by 513.8 ± 239.3 ms after caffeine ingestion (p < 0.001). VTT measured with VICTR MRI revealed a strong correlation (R = 0.84, p = 0.002) with that measured with the contrast-based approach. VTT was found inversely correlated to cerebral blood flow and venous oxygenation across individuals. CONCLUSION: A noncontrast MRI technique, VICTR MRI, was developed to measure the VTT of the brain.


Assuntos
Veias Cerebrais , Imageamento por Ressonância Magnética , Humanos , Masculino , Adulto , Feminino , Velocidade do Fluxo Sanguíneo/fisiologia , Veias Cerebrais/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Circulação Cerebrovascular/fisiologia , Reprodutibilidade dos Testes , Cafeína/farmacologia , Meios de Contraste , Adulto Jovem , Processamento de Imagem Assistida por Computador/métodos , Hemodinâmica , Angiografia por Ressonância Magnética/métodos
10.
Magn Reson Chem ; 62(3): 190-197, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38237932

RESUMO

Since 1993, it has been known that 13 C chemical shift tensor (i.e., δ11 , δ22 , and δ33 ) provides information sufficient to distinguish between COOH and COO- sites. Herein, four previously unreported metrics are proposed for differentiating COOH/COO- moieties. A new relationship is also introduced that correlates the asymmetry (i.e., δ11 -δ22 ) of COOH sites to the proximity of hydrogen bond donating partners within 2.6 Å with high accuracy (±0.05 Å). Conversely, a limitation to all proposed metrics is that they fail to distinguish between COO- and hydrogen disordered COOH sites. To reconcile this omission, a new approach is proposed based on T1 measurements of both 1 H and 13 C. The 13 C T1 values are particularly sensitive with the T1 for hydrogen disordered COOH moieties found to be nearly six times smaller than T1 's from COO- sites.

11.
Neuroimage ; 288: 120523, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38278427

RESUMO

Although manganese (Mn) is a trace metal essential for humans, chronic exposure to Mn can cause accumulation of this metal ion in the brain leading to an increased risk of neurological and neurobehavioral health effects. This is a concern for welders exposed to Mn through welding fumes. While brain Mn accumulation in occupational settings has mostly been reported in the basal ganglia, several imaging studies also revealed elevated Mn in other brain areas. Since Mn functions as a magnetic resonance imaging (MRI) T1 contrast agent, we developed a whole-brain MRI approach to map in vivo Mn deposition differences in the brains of non-exposed factory controls and exposed welders. This is a cross-sectional analysis of 23 non-exposed factory controls and 36 exposed full-time welders from the same truck manufacturer. We collected high-resolution 3D MRIs of brain anatomy and R1 relaxation maps to identify regional differences using voxel-based quantification (VBQ) and statistical parametric mapping. Furthermore, we investigated the associations between excess Mn deposition and neuropsychological and motor test performance. Our results indicate that: (1) Using whole-brain MRI relaxometry methods we can generate excess Mn deposition maps in vivo, (2) excess Mn accumulation due to occupational exposure occurs beyond the basal ganglia in cortical areas associated with motor and cognitive functions, (3) Mn likely diffuses along white matter tracts in the brain, and (4) Mn deposition in specific brain regions is associated with exposure (cerebellum and frontal cortex) and motor metrics (cerebellum and hippocampus).


Assuntos
Manganês , Ferreiros , Humanos , Estudos Transversais , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética , Mapeamento Encefálico
12.
J Magn Reson Imaging ; 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37950398

RESUMO

BACKGROUND: The widely used magnetization-prepared rapid gradient-echo (MPRAGE) sequence makes enhancing lesions and blood vessels appear bright after gadolinium administration. However, dark blood imaging using T1-weighted Sampling Perfection with Application optimized Contrast using different flip angle Evolution (T1 SPACE) can be advantageous since it improves the conspicuity of small metastases and leptomeningeal disease. As a potential alternative to T1 SPACE, we evaluated a new dark blood sequence called echo-uT1 RESS (unbalanced T1 Relaxation-Enhanced Steady-State). PURPOSE: We compared the performance of echo-uT1 RESS with Dixon fid-uT1 RESS, MPRAGE, and T1 SPACE. STUDY TYPE: Retrospective, IRB approved. SUBJECTS/PHANTOM: Phantom to assess flow properties of echo-uT1 RESS. Twenty-one patients (14 female, age range 35-82 years) with primary and secondary brain tumors. FIELD STRENGTH/SEQUENCES: 3 Tesla/MPRAGE, T1 SPACE, Dixon fid-uT1 RESS, echo-uT1 RESS. ASSESSMENT: Flow phantom signal vs. velocity as a function of flip angle and sequence. Qualitative image assessment on 4-point scale. Quantitative evaluation of tumor-to-brain contrast, apparent contrast-to-noise ratio (aCNR), and vessel-to-brain aCNR. STATISTICAL TESTS: Friedman and Mann-Whitney U tests. A P value <0.05 was considered statistically significant. RESULTS: In the phantom, echo-uT1 RESS showed greater flow-dependent signal loss than fid-uT1 RESS. In patients, blood vessels appeared bright with MPRAGE, gray with fid-uT1 RESS, and dark with T1 SPACE and echo-uT1 RESS. For MPRAGE, Dixon fid-uT1 RESS, echo-uT1 RESS, and T1 SPACE, respective tumor-to-brain contrast values were 0.6 ± 0.3, 1.3 ± 0.5, 1.0 ± 0.4, and 0.6 ± 0.4, while normalized aCNR values were 68.9 ± 50.9, 128.4 ± 59.2, 74.2 ± 42.1, and 99.4 ± 73.9. DATA CONCLUSION: Volumetric dark blood contrast-enhanced brain MRI is feasible using echo-uT1 RESS. The dark blood effect was improved vs. fid-uT1 RESS, while both uT1 RESS versions provided better tumor-to-brain contrast than MPRAGE. Whereas T1 SPACE provided better tumor aSNR, echo-uT1 RESS provided better Weber contrast, lesion sharpness and a more consistent dark blood effect. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 1.

13.
Mult Scler ; 29(11-12): 1406-1417, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37712486

RESUMO

BACKGROUND: Paramagnetic rim lesions (PRLs) are an imaging biomarker in multiple sclerosis (MS), associated with a more severe disease. OBJECTIVES: To determine quantitative magnetic resonance imaging (MRI) metrics of PRLs, lesions with diffuse susceptibility-weighted imaging (SWI)-hypointense signal (DSHLs) and SWI-isointense lesions (SILs), their surrounding periplaque area (PPA) and the normal-appearing white matter (NAWM). METHODS: In a cross-sectional study, quantitative MRI metrics were measured in people with multiple sclerosis (pwMS) using the multi-dynamic multi-echo (MDME) sequence post-processing software "SyMRI." RESULTS: In 30 pwMS, 59 PRLs, 74 DSHLs, and 107 SILs were identified. Beside longer T1 relaxation times of PRLs compared to DSHLs and SILs (2030.5 (1519-2540) vs 1615.8 (1403.3-1953.5) vs 1199.5 (1089.6-1334.6), both p < 0.001), longer T1 relaxation times were observed in the PRL PPA compared to the SIL PPA and the NAWM but not the DSHL PPA. Patients with secondary progressive multiple sclerosis (SPMS) had longer T1 relaxation times in PRLs compared to patients with late relapsing multiple sclerosis (lRMS) (2394.5 (2030.5-3040) vs 1869.3 (1491.4-2451.3), p = 0.015) and also in the PRL PPA compared to patients with early relapsing multiple sclerosis (eRMS) (982 (927-1093.5) vs 904.3 (793.3-958.5), p = 0.013). CONCLUSION: PRLs are more destructive than SILs, leading to diffuse periplaque white matter (WM) damage. The quantitative MRI-based evaluation of the PRL PPA could be a marker for silent progression in pwMS.


Assuntos
Esclerose Múltipla , Substância Branca , Humanos , Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla/patologia , Substância Branca/diagnóstico por imagem , Substância Branca/patologia , Estudos Transversais , Encéfalo/patologia , Imageamento por Ressonância Magnética/métodos
14.
J Imaging ; 9(8)2023 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-37623683

RESUMO

Knowledge of the relative performance of the well-known sparse and low-rank compressed sensing models with 3D radial quantitative magnetic resonance imaging acquisitions is limited. We use 3D radial T1 relaxation time mapping data to compare the total variation, low-rank, and Huber penalty function approaches to regularization to provide insights into the relative performance of these image reconstruction models. Simulation and ex vivo specimen data were used to determine the best compressed sensing model as measured by normalized root mean squared error and structural similarity index. The large-scale compressed sensing models were solved by combining a GPU implementation of a preconditioned primal-dual proximal splitting algorithm to provide high-quality T1 maps within a feasible computation time. The model combining spatial total variation and locally low-rank regularization yielded the best performance, followed closely by the model combining spatial and contrast dimension total variation. Computation times ranged from 2 to 113 min, with the low-rank approaches taking the most time. The differences between the compressed sensing models are not necessarily large, but the overall performance is heavily dependent on the imaged object.

15.
Front Neurosci ; 17: 1209521, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37638307

RESUMO

Axon radius is a potential biomarker for brain diseases and a crucial tissue microstructure parameter that determines the speed of action potentials. Diffusion MRI (dMRI) allows non-invasive estimation of axon radius, but accurately estimating the radius of axons in the human brain is challenging. Most axons in the brain have a radius below one micrometer, which falls below the sensitivity limit of dMRI signals even when using the most advanced human MRI scanners. Therefore, new MRI methods that are sensitive to small axon radii are needed. In this proof-of-concept investigation, we examine whether a surface-based axonal relaxation process could mediate a relationship between intra-axonal T2 and T1 times and inner axon radius, as measured using postmortem histology. A unique in vivo human diffusion-T1-T2 relaxation dataset was acquired on a 3T MRI scanner with ultra-strong diffusion gradients, using a strong diffusion-weighting (i.e., b = 6,000 s/mm2) and multiple inversion and echo times. A second reduced diffusion-T2 dataset was collected at various echo times to evaluate the model further. The intra-axonal relaxation times were estimated by fitting a diffusion-relaxation model to the orientation-averaged spherical mean signals. Our analysis revealed that the proposed surface-based relaxation model effectively explains the relationship between the estimated relaxation times and the histological axon radius measured in various corpus callosum regions. Using these histological values, we developed a novel calibration approach to predict axon radius in other areas of the corpus callosum. Notably, the predicted radii and those determined from histological measurements were in close agreement.

16.
Magn Reson Imaging ; 103: 1-7, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37392804

RESUMO

OBJECTIVE: Alternative contrast agents for MRI are needed for individuals who may respond adversely to gadolinium, and need an intravascular agent for specific indications. One potential contrast agent is intracellular methemoglobin, a paramagnetic molecule that is normally present in small amounts in red blood cells. An animal model was used to determine whether methemoglobin modulation with intravenous sodium nitrite transiently changes the T1 relaxation of blood. METHODS: Four adult New Zealand white rabbits were treated with 30 mg intravenous sodium nitrite. 3D TOF and 3D MPRAGE images were acquired before (baseline) and after methemoglobin modulation. T1 of blood was measured with 2D ss EPl acquisitions with inversion recovery preparation performed at two-minute intervals up to 30 min. T1 maps were calculated by fitting the signal recovery curve within major blood vessels. RESULTS: Baseline T1 was 1758 ± 53 ms in carotid arteries and 1716 ± 41 ms in jugular veins. Sodium nitrite significantly changed intravascular T1 relaxation. The mean minimum value of T1 was 1126 ± 28 ms in carotid arteries 8 to 10 min after the injection of sodium nitrite. The mean minimum value of T1 was 1171 ± 52 ms in jugular veins 10 to 14 min after the injection of sodium nitrite. Arterial and venous T1 recovered to baseline after a period of 30 min. CONCLUSION: Methemoglobin modulation produces intravascular contrast on T1-weighted MRI in vivo. Additional studies are needed to safely optimize methemoglobin modulation and sequence parameters for maximal tissue contrast.


Assuntos
Meios de Contraste , Metemoglobina , Coelhos , Animais , Nitrito de Sódio , Imageamento por Ressonância Magnética/métodos , Imageamento Tridimensional
17.
J Cardiovasc Dev Dis ; 10(6)2023 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-37367417

RESUMO

(1) Background: Longitudinal changes in myocardial T1 relaxation time are unknown. We aimed to assess the longitudinal changes in the left ventricular (LV) myocardial T1 relaxation time and LV function. (2) Methods: Fifty asymptomatic men (mean age, 52.0 years) who underwent 1.5 T cardiac magnetic resonance imaging twice at an interval of 54 ± 21 months were included in this study. The LV myocardial T1 times and extracellular volume fractions (ECVFs) were calculated using the MOLLI technique (before and 15 min after gadolinium contrast injection). The 10-year Atherosclerotic Cardiovascular Disease (ASCVD) risk score was calculated. (3) Results: No significant differences in the following parameters were noted between the initial and follow-up assessments: LV ejection fraction (65.0 ± 6.7% vs. 63.6 ± 6.3%, p = 0.12), LV mass/end-diastolic volume ratio (0.82 ± 0.12 vs. 0.80 ± 0.14, p = 0.16), native T1 relaxation time (982 ± 36 vs. 977 ± 37 ms, p = 0.46), and ECVF (24.97 ± 2.38% vs. 25.02 ± 2.41%, p = 0.89). The following parameters decreased significantly from the initial assessment to follow-up: stroke volume (87.2 ± 13.7 mL vs. 82.6 ± 15.3 mL, p = 0.01), cardiac output (5.79 ± 1.17 vs. 5.50 ± 1.04 L/min, p = 0.01), and LV mass index (110.16 ± 22.38 vs. 104.32 ± 18.26 g/m2, p = 0.01). The 10-year ASCVD risk score also remained unchanged between the two timepoints (4.71 ± 0.19% vs. 5.16 ± 0.24%, p = 0.14). (4) Conclusion: Myocardial T1 values and ECVFs were stable over time in the same middle-aged men.

18.
J Int Med Res ; 51(6): 3000605231179817, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37282498

RESUMO

With the advancement of magnetic resonance imaging (MRI) techniques, general radiographic methods are no longer sufficient for accurately displaying the structure and pathway of cranial nerves. Various sequences, including 3-dimensional sampling perfection with application-optimized contrast using different flip angle evolution (SPACE), have been developed through MRI technology to effectively display the location and severity of damaged cranial nerves. This current case report describes a 36-year-old male patient with multiple cranial nerve injuries resulting from an invasive Mucor infection. While performing MRI scanning on this patient, a 1-h delayed enhanced MRI 3D-T1 SPACE short tau inversion recovery (STIR) sequence proved more effective in eliminating background interference and assessing neurological damage with greater clarity than conventional enhancement methods. This approach may prove beneficial in accurately evaluating the extent of cranial neuropathy, thus facilitating clinical applications.


Assuntos
Gadolínio , Imageamento por Ressonância Magnética , Masculino , Humanos , Adulto , Imageamento por Ressonância Magnética/métodos , Nervos Cranianos/diagnóstico por imagem , Imageamento Tridimensional
19.
J Orthop Res ; 41(12): 2657-2666, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37203565

RESUMO

The aim of this study is to assess whether articular cartilage changes in an equine model of post-traumatic osteoarthritis (PTOA), induced by surgical creation of standard (blunt) grooves, and very subtle sharp grooves, could be detected with ex vivo T1 relaxation time mapping utilizing three-dimensional (3D) readout sequence with zero echo time. Grooves were made on the articular surfaces of the middle carpal and radiocarpal joints of nine mature Shetland ponies and osteochondral samples were harvested at 39 weeks after being euthanized under respective ethical permissions. T1 relaxation times of the samples (n = 8 + 8 for experimental and n = 12 for contralateral controls) were measured with a variable flip angle 3D multiband-sweep imaging with Fourier transform sequence. Equilibrium and instantaneous Young's moduli and proteoglycan (PG) content from OD of Safranin-O-stained histological sections were measured and utilized as reference parameters for the T1 relaxation times. T1 relaxation time was significantly (p < 0.05) increased in both groove areas, particularly in the blunt grooves, compared with control samples, with the largest changes observed in the superficial half of the cartilage. T1 relaxation times correlated weakly (Rs ≈ 0.33) with equilibrium modulus and PG content (Rs ≈ 0.21). T1 relaxation time in the superficial articular cartilage is sensitive to changes induced by the blunt grooves but not to the much subtler sharp grooves, at the 39-week timepoint post-injury. These findings support that T1 relaxation time has potential in detection of mild PTOA, albeit the most subtle changes could not be detected.


Assuntos
Ossos do Carpo , Cartilagem Articular , Osteoartrite , Cavalos , Animais , Imageamento por Ressonância Magnética/métodos , Cartilagem Articular/patologia , Osteoartrite/diagnóstico por imagem , Osteoartrite/etiologia , Osteoartrite/patologia , Articulação do Punho , Proteoglicanas
20.
Magn Reson Med ; 90(2): 708-721, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37145027

RESUMO

PURPOSE: Recent studies indicate that T1 in white matter (WM) is influenced by fiber orientation in B0 . The purpose of the study was to investigate the interrelationships between axon fiber orientation in corpus callosum (CC) and T1 relaxation time in humans in vivo as well as in rat brain ex vivo. METHODS: Volunteers were scanned for relaxometric and diffusion MRI at 3 T and 7 T. Angular T1 plots from WM were computed using fractional anisotropy and fiber-to-field-angle maps. T1 and fiber-to-field angle were measured in five sections of CC to estimate the effects of inherently varying fiber orientations on T1 within the same tracts in vivo. Ex vivo rat-brain preparation encompassing posterior CC was rotated in B0 and T1 , and diffusion MRI images acquired at 9.4 T. T1 angular plots were determined at several rotation angles in B0 . RESULTS: Angular T1 plots from global WM provided reference for estimated fiber orientation-linked T1 changes within CC. In anterior midbody of CC in vivo, where small axons are dominantly present, a shift in axon orientation is accompanied by a change in T1 , matching that estimated from WM T1 data. In CC, where large and giant axons are numerous, the measured T1 change is about 2-fold greater than the estimated one. Ex vivo rotation of the same midsagittal CC region of interest produced angular T1 plots at 9.4 T, matching those observed at 7 T in vivo. CONCLUSION: These data causally link axon fiber orientation in B0 to the T1 relaxation anisotropy in WM.


Assuntos
Substância Branca , Humanos , Substância Branca/diagnóstico por imagem , Corpo Caloso/diagnóstico por imagem , Anisotropia , Axônios , Imagem de Difusão por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA