1.
Sensors (Basel) ; 20(20)2020 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-33096841

RESUMO

The radiation intensity of observed auroras in the far-ultraviolet (FUV) band varies dramatically with location for aerospace applications, requiring a photon counting imaging apparatus with a wide dynamic range. However, combining high spatial resolution imaging with high event rates is technically challenging. We developed an FUV photon counting imaging system for aurora observation. Our system mainly consists of a microchannel plate (MCP) stack readout using a wedge strip anode (WSA) with charge induction and high-speed electronics, such as a charge sensitive amplifier (CSA) and pulse shaper. Moreover, we constructed an anode readout model and a time response model for readout circuits to investigate the counting error in high counting rate applications. This system supports global rates of 500 kilo counts, 0.610 dark counts s-1 cm-2 at an ambient temperature of 300 K and 111 µm spatial resolution at 400 kilo counts s-1 (kcps). We demonstrate an obvious photon count loss at incident intensities close to the counting capacity of the system. To preserve image quality, the response time should be improved and some noise performance may be sacrificed. Finally, we also describe the correlation between counting rate and imaging resolution, which further guides the design of space observation instruments.

2.
J Biophotonics ; 13(2): e201960099, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31661595

RESUMO

We report on wide-field time-correlated single photon counting (TCSPC)-based fluorescence lifetime imaging microscopy (FLIM) with lightsheet illumination. A pulsed diode laser is used for excitation, and a crossed delay line anode image intensifier, effectively a single-photon sensitive camera, is used to record the position and arrival time of the photons with picosecond time resolution, combining low illumination intensity of microwatts with wide-field data collection. We pair this detector with the lightsheet illumination technique, and apply it to 3D FLIM imaging of dye gradients in human cancer cell spheroids, and C. elegans.


Assuntos
Caenorhabditis elegans , Fótons , Animais , Humanos , Lasers , Microscopia de Fluorescência
3.
Nanoscale Res Lett ; 14(1): 153, 2019 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-31062184

RESUMO

As a key component of electron multiplier device, a microchannel plate (MCP) can be applied in many scientific fields. Pure aluminum oxide (Al2O3) as secondary electron emission (SEE) layer were deposited in the pores of MCP via atomic layer deposition (ALD) to overcome problems such as high dark current and low lifetime which often occur on traditional MCP. In this paper, we systematically investigate the morphology, element distribution, and structure of samples by scanning electron microscopy (SEM) and energy disperse spectroscopy (EDS), respectively. Output current of different thickness of Al2O3 was studied and an optimal thickness was found. Experimental tests show that the average gain of ALD-MCP was nearly five times better than that of traditional MCP, and the ALD-MCP showed better sensitivity and longer lifetime.

4.
Nanoscale Res Lett ; 10: 162, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25883544

RESUMO

Microchannel plate (MCP) as a key part is a kind of electron multiplied device applied in many scientific fields. Oxide thin films such as zinc oxide doped with aluminum oxide (ZnO:Al2O3) as conductive layer and pure aluminum oxide (Al2O3) as secondary electron emission (SEE) layer were prepared in the pores of MCP via atomic layer deposition (ALD) which is a method that can precisely control thin film thickness on a substrate with a high aspect ratio structure. In this paper, nano-oxide thin films ZnO:Al2O3 and Al2O3 were prepared onto varied kinds of substrates by ALD technique, and the morphology, element distribution, structure, and surface chemical states of samples were systematically investigated by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), and X-ray photoemission spectroscopy (XPS), respectively. Finally, electrical properties of an MCP device as a function of nano-oxide thin film thickness were firstly studied, and the electrical measurement results showed that the average gain of MCP was greater than 2,000 at DC 800 V with nano-oxide thin film thickness approximately 122 nm. During electrical measurement, current jitter was observed, and possible reasons were preliminarily proposed to explain the observed experimental phenomenon.