1.
Phys Med Biol ; 2024 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-39422080

RESUMO

OBJECTIVE: The highly conformal carbon-ion radiotherapy is associated with an increased sensitivity of the dose distributions to internal changes in the patient during the treatment course. Hence, monitoring methodologies capable of detecting such changes are of vital importance. We established experimental setup conditions to address the sensitivity of a monitoring approach based on secondary-fragment tracking for detecting clinically motivated air cavity dimensions in a homogeneous head-size PMMA phantom in 40 mm depth. APPROACH: The air cavities were positioned within the entrance channel of a treatment field of 50 mm diameter at three lateral positions. The measured secondary-fragment emission profiles were compared to a reference measurement without cavities. The experiments were conducted at the Heidelberg Ion-Beam Therapy Center in Germany at typical doses and dose rates. MAIN RESULTS: Significances above a detectability threshold of 2σ for the larger cavities (20 mm diameter and 4 mm thickness, and 20 mm diameter and 2 mm thickness) across the entire treatment field. The smallest cavity of 10 mm diameter and 2 mm thickness, which is on the lower limit of clinical interest, could not be detected at any position. We also demonstrated that it is feasible to reconstruct the lateral position of the cavity on average within 2.8 mm, once the cavity is detected. This is sufficient for the clinicians to estimate medical effects of such a cavity and to decide about the need for a control imaging CT. SIGNIFICANCE: This investigation defines well-controlled reference conditions for the evaluation of the performance of any kind of treatment monitoring method and its capability to detect internal changes within head-sized objects. Air cavities with volumes from 0.31 cm3 to 1.26 cm3 were narrowed down around the detectability threshold of this secondary-fragment-based monitoring method.

2.
Microscopy (Oxf) ; 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38822660

RESUMO

We have developed a high-speed recordable direct electron detector based on silicon-on-insulator technology. The detector has sixteen analog memories in each pixel to record sixteen images with sub-microsecond temporal resolution. A dedicated data acquisition system has also been developed to display and record the results on a personal computer. The performance of the direct electron detector as an image sensor is evaluated under electron irradiation with an energy of 30 keV in a low-voltage transmission electron microscope equipped with a photocathode electron gun. We demonstrate that the detector can record images at an exposure time of 100 ns and an interval of 900 ns.

3.
Sensors (Basel) ; 24(8)2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38676004

RESUMO

To monitor the position and profile of therapeutic carbon beams in real-time, in this paper, we proposed a system called HiBeam-T. The HiBeam-T is a time projection chamber (TPC) with forty Topmetal-II- CMOS pixel sensors as its readout. Each Topmetal-II- has 72 × 72 pixels with the size of 83 µm × 83 µm. The detector consists of the charge drift region and the charge collection area. The readout electronics comprise three Readout Control Modules and one Clock Synchronization Module. This Hibeam-T has a sensitive area of 20 × 20 cm and can acquire the center of the incident beams. The test with a continuous 80.55 MeV/u 12C6+ beam shows that the measurement resolution to the beam center could reach 6.45 µm for unsaturated beam projections.

4.
Life Sci Space Res (Amst) ; 39: 52-58, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37945089

RESUMO

We detect regular particle showers in several compact pixel detectors, distributed over the International Space Station. These showers are caused by high energy galactic cosmic rays, with energies often in the 10 s of TeV or higher. We survey the frequency of these events, their dependence on location on ISS, and their independence of the location of ISS, on its orbit. The Timepix detectors used allow individual particle tracks to be resolved, providing a possibility to perform physical analysis of shower events, which we demonstrate. In terms of radiation dosimetry, these showers indicate certain possible limitations of traditional dosimetric measures, in that (a) the dose measured in small sensor may be less than that received in a larger distribution of matter, such as a human and (b) the spatial and temporal extent of these events represents a regime of poorly documented biological response.


Assuntos
Radiação Cósmica , Monitoramento de Radiação , Voo Espacial , Humanos , Doses de Radiação , Astronave , Radiometria
5.
Phys Med Biol ; 68(18)2023 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-37607560

RESUMO

Objective.This work presents a method for enhanced detection, imaging, and measurement of the thermal neutron flux.Approach. Measurements were performed in a water tank, while the detector is positioned out-of-field of a 20 MeV ultra-high pulse dose rate electron beam. A semiconductor pixel detector Timepix3 with a silicon sensor partially covered by a6LiF neutron converter was used to measure the flux, spatial, and time characteristics of the neutron field. To provide absolute measurements of thermal neutron flux, the detection efficiency calibration of the detectors was performed in a reference thermal neutron field. Neutron signals are recognized and discriminated against other particles such as gamma rays and x-rays. This is achieved by the resolving power of the pixel detector using machine learning algorithms and high-resolution pattern recognition analysis of the high-energy tracks created by thermal neutron interactions in the converter.Main results. The resulting thermal neutrons equivalent dose was obtained using conversion factor (2.13(10) pSv·cm2) from thermal neutron fluence to thermal neutron equivalent dose obtained by Monte Carlo simulations. The calibrated detectors were used to characterize scattered radiation created by electron beams. The results at 12.0 cm depth in the beam axis inside of the water for a delivered dose per pulse of 1.85 Gy (pulse length of 2.4µs) at the reference depth, showed a contribution of flux of 4.07(8) × 103particles·cm-2·s-1and equivalent dose of 1.73(3) nSv per pulse, which is lower by ∼9 orders of magnitude than the delivered dose.Significance. The presented methodology for in-water measurements and identification of characteristic thermal neutrons tracks serves for the selective quantification of equivalent dose made by thermal neutrons in out-of-field particle therapy.


Assuntos
Algoritmos , Elétrons , Calibragem , Raios gama , Nêutrons
6.
Sensors (Basel) ; 23(13)2023 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-37447694

RESUMO

Depleted Monolithic Active Pixel Sensors (DMAPSs) are foreseen as an interesting choice for future high-energy physics experiments, mainly because of the reduced fabrication costs. However, they generally offer limited time resolution due to the stringent requirements of area and power consumption imposed by the targeted spatial resolution. This work describes a methodology to optimize the design of time-to-digital converter (TDC)-based timing electronics that takes advantage of the asymmetrical shape of the pulse at the output of the analog front-end (AFE). Following that methodology, a power and area efficient implementation fully compatible with the RD50-MPW3 solution is proposed. Simulation results show that the proposed solution offers a time resolution of 2.08 ns for a range of energies from 1000 e- to 20,000 e-, with minimum area and zero quiescent in-pixel power consumption.


Assuntos
Eletrônica , Tomografia por Emissão de Pósitrons , Tomografia por Emissão de Pósitrons/métodos , Fatores de Tempo , Simulação por Computador
7.
Ultramicroscopy ; 253: 113777, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37336162

RESUMO

Hybrid pixel direct electron detectors are gaining popularity in electron microscopy due to their excellent properties. Some commercial cameras based on this technology are relatively affordable which makes them attractive tools for experimentation especially in combination with an SEM setup. To support this, a detector characterization (Modulation Transfer Function, Detective Quantum Efficiency) of an Advacam Minipix and Advacam Advapix detector in the 15-30 keV range was made. In the current work we present images of Point Spread Function, plots of MTF/DQE curves and values of DQE(0) for these detectors. At low beam currents, the silicon detector layer behaviour should be dominant, which could make these findings transferable to any other available detector based on either Medipix2, Timepix or Timepix3 provided the same detector layer is used.

8.
J Synchrotron Radiat ; 30(Pt 4): 723-738, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37343017

RESUMO

The ability to utilize a hybrid-photon-counting detector to its full potential can significantly influence data quality, data collection speed, as well as development of elaborate data acquisition schemes. This paper facilitates the optimal use of EIGER2 detectors by providing theory and practical advice on (i) the relation between detector design, technical specifications and operating modes, (ii) the use of corrections and calibrations, and (iii) new acquisition features: a double-gating mode, 8-bit readout mode for increasing temporal resolution, and lines region-of-interest readout mode for frame rates up to 98 kHz. Examples of the implementation and application of EIGER2 at several synchrotron sources (ESRF, PETRA III/DESY, ELETTRA, AS/ANSTO) are presented: high accuracy of high-throughput data in serial crystallography using hard X-rays; suppressing higher harmonics of undulator radiation, improving peak shapes, increasing data collection speed in powder X-ray diffraction; faster ptychography scans; and cleaner and faster pump-and-probe experiments.


Assuntos
Fótons , Síncrotrons , Raios X , Radiografia , Difração de Raios X
9.
Sensors (Basel) ; 22(15)2022 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-35957449

RESUMO

In this work, we investigate the potential of employing a direct conversion integration mode X-ray detector with micron-scale pixels in two different X-ray phase-contrast imaging (XPCi) configurations, propagation-based (PB) and edge illumination (EI). Both PB-XPCi and EI-XPCi implementations are evaluated through a wave optics model-numerically simulated in MATLAB-and are compared based on their contrast, edge-enhancement, visibility, and dose efficiency characteristics. The EI-XPCi configuration, in general, demonstrates higher performance compared to PB-XPCi, considering a setup with the same X-ray source and detector. However, absorption masks quality (thickness of X-ray absorption material) and environmental vibration effect are two potential challenges for EI-XPCi employing a detector with micron-scale pixels. Simulation results confirm that the behavior of an EI-XPCi system employing a high-resolution detector is susceptible to its absorption masks thickness and misalignment. This work demonstrates the potential and feasibility of employing a high-resolution direct conversion detector for phase-contrast imaging applications where higher dose efficiency, higher contrast images, and a more compact imaging system are of interest.


Assuntos
Iluminação , Simulação por Computador , Radiografia , Raios X
10.
Phys Med ; 101: 79-86, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35985102

RESUMO

The track structure of the signal measured by the semiconductor pixel detector Timepix3 was modelled in the Monte Carlo MCNP® code. A detailed model at the pixel-level (256 × 256 pixels, 55 × 55 µm2 pixel size) was developed and used to generate and store clusters of adjacent hit pixels observed in the measured data because of particle energy deposition path, charge sharing, and drift processes. An analytical model of charge sharing effect and the detector energy resolution was applied to the simulated data. The method will help the user sort the measured clusters and distinguish radiation components of mixed fields by determining the response of Timepix3 detector to particular particle types, energies, and incidence angles that cannot be measured separately.

11.
Med Phys ; 49(3): 1776-1792, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35073413

RESUMO

PURPOSE: Noninvasive methods to monitor carbon-ion beams in patients are desired to fully exploit the advantages of carbon-ion radiotherapy. Prompt secondary ions produced in nuclear fragmentations of carbon ions are of particular interest for monitoring purposes as they can escape the patient and thus be detected and tracked to measure the radiation field in the irradiated object. This study aims to evaluate the performance of secondary-ion tracking to detect, visualize, and localize an internal air cavity used to mimic inter-fractional changes in the patient anatomy at different depths along the beam axis. METHODS: In this work, a homogeneous head phantom was irradiated with a realistic carbon-ion treatment plan with a typical prescribed fraction dose of 3 Gy(RBE). Secondary ions were detected by a mini-tracker with an active area of 2 cm2 , based on the Timepix3 semiconductor pixel detector technology. The mini-tracker was placed 120 mm behind the center of the target at an angle of 30 degrees with respect to the beam axis. To assess the performance of the developed method, a 2-mm thick air cavity was inserted in the head phantom at several depths: in front of as well as at the entrance, in the middle, and at the distal end of the target volume. Different reconstruction methods of secondary-ion emission profile were studied using the FLUKA Monte Carlo simulation package. The perturbations in the emission profiles caused by the air cavity were analyzed to detect the presence of the air cavity and localize its position. RESULTS: The perturbations in the radiation field mimicked by the 2-mm thick cavity were found to be significant. A detection significance of at least three standard deviations in terms of spatial distribution of the measured tracks was found for all investigated cavity depths, while the highest significance (six standard deviations) was obtained when the cavity was located upstream of the tumor. For a tracker with an eight-fold sensitive area, the detection significance rose to at least nine standard deviations and up to 17 standard deviations, respectively. The cavity could be detected at all depths and its position measured within 6.5 ± 1.4 mm, which is sufficient for the targeted clinical performance of 10 mm. CONCLUSION: The presented systematic study concerning the detection and localization of small inter-fractional structure changes in a realistic clinical setting demonstrates that secondary ions carry a large amount of information on the internal structure of the irradiated object and are thus attractive to be further studied for noninvasive monitoring of carbon-ion treatments.


Assuntos
Carbono , Radioterapia com Íons Pesados , Carbono/uso terapêutico , Radioterapia com Íons Pesados/métodos , Humanos , Íons , Método de Monte Carlo , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica
12.
Front Oncol ; 11: 780221, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34912718

RESUMO

The dose conformity of carbon-ion beam radiotherapy, which allows the reduction of the dose deposition in healthy tissue and the escalation of the dose to the tumor, is associated with a high sensitivity to anatomical changes during and between treatment irradiations. Thus, the monitoring of inter-fractional anatomical changes is crucial to ensure the dose conformity, to potentially reduce the size of the safety margins around the tumor and ultimately to reduce the irradiation of healthy tissue. To do so, monitoring methods of carbon-ion radiotherapy in depth using secondary-ion tracking are being investigated. In this work, the detection and localization of a small air cavity of 2 mm thickness were investigated at different detection angles of the mini-tracker relative to the beam axis. The experiments were conducted with a PMMA head phantom at the Heidelberg Ion-Beam Therapy Center (HIT) in Germany. In a clinic-like irradiation of a single field of 3 Gy (RBE), secondary-ion emission profiles were measured by a 2 cm2 mini-tracker composed of two silicon pixel detectors. Two positions of the cavity in the head phantom were studied: in front and in the middle of the tumor volume. The significance of the cavity detection was found to be increased at smaller detection angles, while the accuracy of the cavity localization was improved at larger detection angles. Detection angles of 20° - 30° were found to be a good compromise for accessing both, the detectability and the position of the air cavity along the depth in the head of a patient.

13.
Sensors (Basel) ; 21(9)2021 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-34066764

RESUMO

Cadmium zinc telluride (CdZnTe) detectors are known to suffer from polarization effects under high photon flux due to poor hole transport in the crystal material. This has led to the development of a high-flux capable CdZnTe material (HF-CdZnTe). Detectors with the HF-CdZnTe material have shown promising results at mitigating the onset of the polarization phenomenon, likely linked to improved crystal quality and hole carrier transport. Better hole transport will have an impact on charge collection, particularly in pixelated detector designs and thick sensors (>1 mm). In this paper, the presence of charge sharing and the magnitude of charge loss were calculated for a 2 mm thick pixelated HF-CdZnTe detector with 250 µm pixel pitch and 25 µm pixel gaps, bonded to the STFC HEXITEC ASIC. Results are compared with a CdTe detector as a reference point and supported with simulations from a Monte-Carlo detector model. Charge sharing events showed minimal charge loss in the HF-CdZnTe, resulting in a spectral resolution of 1.63 ± 0.08 keV Full Width at Half Maximum (FWHM) for bipixel charge sharing events at 59.5 keV. Depth of interaction effects were shown to influence charge loss in shared events. The performance is discussed in relation to the improved hole transport of HF-CdZnTe and comparison with simulated results provided evidence of a uniform electric field.

14.
Med Phys ; 48(8): 4411-4424, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34061994

RESUMO

PURPOSE: Ion beam radiotherapy offers enhances dose conformity to the tumor volume while better sparing healthy tissue compared to conventional photon radiotherapy. However, the increased dose gradient also makes it more sensitive to uncertainties. While the most important uncertainty source is the patient itself, the beam delivery is also subject to uncertainties. Most of the proton therapy centers used cyclotrons, which deliver typically a stable beam over time, allowing a continuous extraction of the beam. Carbon-ion beam radiotherapy (CIRT) in contrast uses synchrotrons and requires a larger and energy-dependent extrapolation of the nozzle-measured positions to obtain the lateral beam positions in the isocenter, since the nozzle-to-isocenter distance is larger than for cyclotrons. Hence, the control of lateral pencil beam positions at isocenter in CIRT is more sensitive to uncertainties than in proton radiotherapy. Therefore, an independent monitoring of the actual lateral positions close to the isocenter would be very valuable and provide additional information. However, techniques capable to do so are scarce, and they are limited in precision, accuracy and effectivity. METHODS: The detection of secondary ions (charged nuclear fragments) has previously been exploited for the Bragg peak position of C-ion beams. In our previous work, we investigated for the first time the feasibility of lateral position monitoring of pencil beams in CIRT. However, the reported precision and accuracy were not sufficient for a potential implementation into clinical practice. In this work, it is shown how the performance of the method is improved to the point of clinical relevance. To minimize the observed uncertainties, a mini-tracker based on hybrid silicon pixel detectors was repositioned downstream of an anthropomorphic head phantom. However, the secondary-ion fluence rate in the mini-tracker rises up to 1.5 × 105 ions/s/cm2 , causing strong pile-up of secondary-ion signals. To solve this problem, we performed hardware changes, optimized the detector settings, adjusted the setup geometry and developed new algorithms to resolve ambiguities in the track reconstruction. The performance of the method was studied on two treatment plans delivered with a realistic dose of 3 Gy (RBE) and averaged dose rate of 0.27 Gy/s at the Heidelberg Ion-Beam Therapy Center (HIT) in Germany. The measured lateral positions were compared to reference beam positions obtained either from the beam nozzle or from a multi-wire proportional chamber positioned at the room isocenter. RESULTS: The presented method is capable to simultaneously monitor both lateral pencil beam coordinates over the entire tumor volume during the treatment delivery, using only a 2-cm2 mini-tracker. The effectivity (defined as the fraction of analyzed pencil beams) was 100%. The reached precision of (0.6 to 1.5) mm and accuracy of (0.5 to 1.2) mm are in line with the clinically accepted uncertainty for QA measurements of the lateral pencil beam positions. CONCLUSIONS: It was demonstrated that the performance of the method for a non-invasive lateral position monitoring of pencil beams is sufficient for a potential clinical implementation. The next step is to evaluate the method clinically in a group of patients in a future observational clinical study.


Assuntos
Radioterapia com Íons Pesados , Terapia com Prótons , Carbono , Humanos , Íons , Método de Monte Carlo , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
15.
Ultramicroscopy ; 227: 113298, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34051540

RESUMO

Hybrid pixel detectors (HPDs) have been shown to be highly effective for diffraction-based and time-resolved studies in transmission electron microscopy, but their performance is limited by the fact that high-energy electrons scatter over long distances in their thick Si sensors. An advantage of HPDs compared to monolithic active pixel sensors is that their sensors do not need to be fabricated from Si. We have compared the performance of the Medipix3 HPD with a Si sensor and a GaAs:Cr sensor using primary electrons in the energy range of 60-300 keV. We describe the measurement and calculation of the detectors' modulation transfer function (MTF) and detective quantum efficiency (DQE), which show that the performance of the GaAs:Cr device is markedly superior to that of the Si device for high-energy electrons.

16.
Microscopy (Oxf) ; 70(3): 321-325, 2021 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-33180139

RESUMO

The performance of a direct electron detector using silicon-on-insulator (SOI) technology in a low-voltage transmission electron microscope (LVTEM) is evaluated. The modulation transfer function and detective quantum efficiency of the detector are measured under backside illumination. The SOI-type detector is demonstrated to have high sensitivity and high efficiency for the direct detection of low-energy electrons. The detector is thus considered suitable for low-dose imaging in an LVTEM.

17.
Ultramicroscopy ; 217: 113067, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32801089

RESUMO

We characterize a hybrid pixel direct detector and demonstrate its suitability for electron energy loss spectroscopy (EELS). The detector has a large dynamic range, narrow point spread function, detective quantum efficiency ≥ 0.8 even without single electron arrival discrimination, and it is resilient to radiation damage. It is capable of detecting ~5 × 106 electrons/pixel/second, allowing it to accommodate up to 0.8 pA per pixel and hence >100 pA EELS zero-loss peak (ZLP) without saturation, if the ZLP is spread over >125 pixels (in the non-dispersion direction). At the same time, it can reliably detect isolated single electrons in the high loss region of the spectrum. The detector uses a selectable threshold to exclude low energy events, and this results in essentially zero dark current and readout noise. Its maximum frame readout rate at 16-bit digitization is 2250 full frames per second, allowing for fast spectrum imaging. We show applications including EELS of boron nitride in which an unsaturated zero loss peak is recorded at the same time as inner shell loss edges, elemental mapping of an STO/BTO/LMSO multilayer, and efficient parallel acquisition of angle-resolved EEL spectra (S(q, ω)) of boron nitride.

18.
Sensors (Basel) ; 20(10)2020 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-32408497

RESUMO

Since the late 2000s, the availability of high-quality cadmium zinc telluride (CdZnTe) has greatly increased. The excellent spectroscopic performance of this material has enabled the development of detectors with volumes exceeding 1 cm3 for use in the detection of nuclear materials. CdZnTe is also of great interest to the photon science community for applications in X-ray imaging cameras at synchrotron light sources and free electron lasers. Historically, spatial variations in the crystal properties and temporal instabilities under high-intensity irradiation has limited the use of CdZnTe detectors in these applications. Recently, Redlen Technologies have developed high-flux-capable CdZnTe material (HF-CdZnTe), which promises improved spatial and temporal stability. In this paper, the results of the characterization of 10 HF-CdZnTe detectors with dimensions of 20.35 mm × 20.45 mm × 2.00 mm are presented. Each sensor has 80 × 80 pixels on a 250-m pitch and were flip-chip-bonded to the STFC HEXITEC ASIC. These devices show excellent spectroscopic performance at room temperature, with an average Full Width at Half Maximum (FWHM) of 0.83 keV measured at 59.54 keV. The effect of tellurium inclusions in these devices was found to be negligible; however, some detectors did show significant concentrations of scratches and dislocation walls. An investigation of the detector stability over 12 h of continuous operation showed negligible changes in performance.

19.
Med Phys ; 47(5): 2212-2221, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31995641

RESUMO

PURPOSE: Ion-beam radiography exhibits a significantly lower spatial resolution (SR) compared to x-ray radiography. This is mostly due the multiple Coulomb scattering (MCS) that the ions undergo in the imaged object. In this work, a novel technique to improve the spatial resolution in helium-beam radiography was developed. Increasing helium-beam energies were exploited in order to decrease the MCS, and therefore increase the SR. METHODS: The experimental investigation was carried out with a dedicated ion-tracking imaging system fully composed of thin, pixelated silicon detectors (Timepix). Four helium beams with increasing energies (from 168.8 to 220.5 MeV/u) were used to image a homogeneous 160 mm PMMA phantom with a 2 mm air gap at middle depth. An energy degrader (ED) was placed between the rear tracking system and the energy-deposition detector to compensate for the longer range associated with more energetic ions. The SR was measured for each beam energy. To take into account the overall impact on the image quality, the contrast-to-noise ratio (CNR), the single-ion water equivalent thickness (WET) precision and the absorbed dose in the phantom were also evaluated as a function of the initial beam energy. FLUKA Monte Carlo simulations were used to support the conceptual design of the experimental setup and for dose estimation. RESULTS: In the investigated energy interval, a total SR increase by around 30% was measured with increasing beam energy, reaching a maximum value of 0.69 lp/mm. For radiographs generated with 350 µGy of absorbed dose and 220 µm pixel size, a CNR decrease of 32% was found as the beam energy increases. For 1 mm pixel size, the CNR decreases only by 22%. The CNR of the images was always above 6. The single-ion WET precision was found to be in a range between 1.2% and 1.5%. CONCLUSIONS: We have experimentally shown and quantified the possibility of improving SR in helium-beam radiography by using increasing beam energies in combination with an ED. A significant SR increase was measured with an acceptable decrease of CNR. Furthermore, we have shown that an ED can be a valuable tool to exploit increasing beam energies to generate energy-deposition radiographs.


Assuntos
Hélio , Intensificação de Imagem Radiográfica/métodos , Razão Sinal-Ruído , Aumento da Imagem , Método de Monte Carlo , Imagens de Fantasmas
20.
Sensors (Basel) ; 19(19)2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-31581431

RESUMO

Sensors for environmental radioactivity based on two novel setups using photodiodes, on the one hand, and an advanced tablet-based hybrid pixel detector, on the other hand, are presented. Measurements of four kinds of terrestrial and every-day radiation sources are carried out: Airborne radon, a mineral containing traces of uranium, edible potassium salt, and an old radium watch. These measurements permit comparisons between different types of ambient radioactive sources and enable environmental monitoring. Available data comprise discrimination between α - and ß - -particles in an energy range of 33 keV to 8 MeV and under ambient air conditions. The diode-based sensor is particularly useful in portable applications since it is small and sturdy with little power consumption. It can be directly connected to a smartphone via the headset socket. For its development, the low-cost silicon positive-intrinsic-negative (PIN) diodes BPX61 and BPW34 have been characterised with capacitance versus voltage (C-V) curves. Physical detection limits for ionising radiation are discussed based on obtained depletion layer width: ( 50 ± 8 ) µ m at 8 V. The mobile and low-cost character of these sensors, as alternatives to Geiger counters or other advanced equipment, allows for a widespread use by individuals and citizen science groups for environmental and health protection purposes, or in educational settings. Source code and hardware design files are released under open source licenses with this publication.

SELEÇÃO DE REFERÊNCIAS