Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Tomography ; 9(1): 299-314, 2023 01 31.
Artigo em Inglês | MEDLINE | ID: mdl-36828376

RESUMO

(1) Background: Radial RARE-EPI MRI facilitates simultaneous T2 and T2* mapping (2in1-RARE-EPI). With modest undersampling (R = 2), the speed gain of 2in1-RARE-EPI relative to Multi-Spin-Echo and Multi-Gradient-Recalled-Echo references is limited. Further reduction in scan time is crucial for clinical studies investigating T2 and T2* as imaging biomarkers. We demonstrate the feasibility of further acceleration, utilizing compressed sensing (CS) reconstruction of highly undersampled 2in1-RARE-EPI. (2) Methods: Two-fold radially-undersampled 2in1-RARE-EPI data from phantoms, healthy volunteers (n = 3), and multiple sclerosis patients (n = 4) were used as references, and undersampled (Rextra = 1-12, effective undersampling Reff = 2-24). For each echo time, images were reconstructed using CS-reconstruction. For T2 (RARE module) and T2* mapping (EPI module), a linear least-square fit was applied to the images. T2 and T2* from CS-reconstruction of undersampled data were benchmarked against values from CS-reconstruction of the reference data. (3) Results: We demonstrate accelerated simultaneous T2 and T2* mapping using undersampled 2in1-RARE-EPI with CS-reconstruction is feasible. For Rextra = 6 (TA = 01:39 min), the overall MAPE was ≤8% (T2*) and ≤4% (T2); for Rextra = 12 (TA = 01:06 min), the overall MAPE was <13% (T2*) and <5% (T2). (4) Conclusion: Substantial reductions in scan time are achievable for simultaneous T2 and T2* mapping of the brain using highly undersampled 2in1-RARE-EPI with CS-reconstruction.


Assuntos
Esclerose Múltipla , Humanos , Esclerose Múltipla/patologia , Imageamento por Ressonância Magnética/métodos , Encéfalo , Imagens de Fantasmas
2.
Magn Reson Med ; 86(3): 1383-1402, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33951214

RESUMO

PURPOSE: The characteristic MRI features of multiple sclerosis (MS) lesions make it conceptually appealing to pursue parametric mapping techniques that support simultaneous generation of quantitative maps of 2 or more MR contrast mechanisms. We present a modular rapid acquisition with relaxation enhancement (RARE)-EPI hybrid that facilitates simultaneous T2 and T2∗ mapping (2in1-RARE-EPI). METHODS: In 2in1-RARE-EPI the first echoes in the echo train are acquired with a RARE module, later echoes are acquired with an EPI module. To define the fraction of echoes covered by the RARE and EPI module, an error analysis of T2 and T2∗ was conducted with Monte Carlo simulations. Radial k-space (under)sampling was implemented for acceleration (R = 2). The feasibility of 2in1-RARE-EPI for simultaneous T2 and T2∗ mapping was examined in a phantom study mimicking T2 and T2∗ relaxation times of the brain. For validation, 2in1-RARE-EPI was benchmarked versus multi spin-echo (MSE) and multi gradient-echo (MGRE) techniques. The clinical applicability of 2in1-RARE-EPI was demonstrated in healthy subjects and MS patients. RESULTS: There was a good agreement between T2 / T2∗ values derived from 2in1-RARE-EPI and T2 / T2∗ reference values obtained from MSE and MGRE in both phantoms and healthy subjects. In patients, MS lesions in T2 and T2∗ maps deduced from 2in1-RARE-EPI could be just as clearly delineated as in reference maps calculated from MSE/MGRE. CONCLUSION: This work demonstrates the feasibility of radially (under)sampled 2in1-RARE-EPI for simultaneous T2 and T2∗ mapping in MS patients.


Assuntos
Esclerose Múltipla , Encéfalo/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Esclerose Múltipla/diagnóstico por imagem , Imagens de Fantasmas , Valores de Referência
3.
Food Res Int ; 114: 97-103, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30361032

RESUMO

The development of non-enzymatic browning in the presence of MgCl2 was evaluated in liquid and dehydrated sucrose-glycine model systems, in relation to interactions of the salt with water and/or with sucrose. In both systems, browning was accelerated by the presence of MgCl2 because of the increased sugar hydrolysis (ten times faster) and the reduction of water mobility (1H NMR T2 relaxation times) caused by this salt (between 6 and 14% lower), counteracting the inhibitory effect of water on the Maillard reaction. MgCl2 also provoked a 40% reduction on the fluorophores quantum yield, responsible also of the fluctuations observed in the fluorescence development as a function of time after 50 h at 70 °C. Molecular and supramolecular effects of the presence of MgCl2 have been observed on the Maillard reaction kinetics. These results are of high technological interest when strategies to control the Maillard reaction rate are required for a particular application.


Assuntos
Glicina/química , Cloreto de Magnésio/química , Reação de Maillard , Modelos Químicos , Sacarose/química , Temperatura Alta , Cinética , Espectroscopia de Ressonância Magnética , Água
4.
J Magn Reson Imaging ; 39(4): 1027-32, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24136653

RESUMO

PURPOSE: To measure both transversal relaxation time (T2 ) and diffusion coefficients within a single scan using a multi-shot approach. Both measurements have drawn interest in many applications, especially in skeletal muscle studies, which have short T2 values. Multiple echo single-shot schemes have been proposed to obtain those variables simultaneously within a single scan, resulting in a reduction of the scanning time. However, one problem with those approaches is the associated long echo read-out. Consequently, the minimum achievable echo time tends to be long, limiting the application of these sequences to tissues with relatively long T2 . MATERIALS AND METHODS: To address this problem, we propose to extend the multi-echo sequences using a multi-shot approach, so that to allow shorter echo times. A multi-shot dual-echo EPI sequence with diffusion gradients and echo navigators was modified to include independent diffusion gradients in any of the two echoes. RESULTS: The multi-shot approach allows us to drastically reduce echo times. Results showed a good agreement for the T2 and mean diffusivity measurements with gold standard sequences in phantoms and in vivo data of calf muscles from healthy volunteers. CONCLUSION: A fast and accurate method is proposed to measure T2 and diffusion coefficients simultaneously, tested in vitro and in healthy volunteers.


Assuntos
Algoritmos , Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Músculo Esquelético/anatomia & histologia , Processamento de Sinais Assistido por Computador , Adulto , Feminino , Humanos , Perna (Membro) , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS