EuroIntervention ; 20(14): e845-e864, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39007831

RESUMO

Transcatheter aortic valve implantation (TAVI) is now utilised as a less invasive alternative to surgical aortic valve replacement (SAVR) across the whole spectrum of surgical risk. Long-term durability of the bioprosthetic valves has become a key goal of TAVI as this procedure is now considered for younger and lower-risk populations. The purpose of this article is to present a state-of-the-art overview on the definition, aetiology, risk factors, mechanisms, diagnosis, clinical impact, and management of bioprosthetic valve dysfunction (BVD) and failure (BVF) following TAVI with a comparative perspective versus SAVR. Structural valve deterioration (SVD) is the main factor limiting the durability of the bioprosthetic valves used for TAVI or SAVR, but non-structural BVD, such as prosthesis-patient mismatch and paravalvular regurgitation, as well as valve thrombosis or endocarditis may also lead to BVF. The incidence of BVF related to SVD or other causes is low (<5%) at midterm (5- to 8-year) follow-up and compares favourably with that of SAVR. The long-term follow-up data of randomised trials conducted with the first generations of transcatheter heart valves also suggest similar valve durability in TAVI versus SAVR at 10 years, but these trials suffer from major survivorship bias, and the long-term durability of TAVI will need to be confirmed by the analysis of the low-risk TAVI versus SAVR trials at 10 years.


Assuntos
Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Fatores de Risco , Bioprótese , Estenose da Valva Aórtica/cirurgia , Falha de Prótese , Resultado do Tratamento , Desenho de Prótese , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos
4.
J Am Coll Cardiol ; 84(3): 317-321, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-38986674

RESUMO

The bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction (BASILICA) procedure allows patients with severe aortic stenosis and anatomical challenges from aortic leaflet orientation, positioning of coronary ostia, and height of sinuses of Valsalva to undergo TAVR. We present a case of intraprocedural cardiac arrest secondary to iatrogenic left main coronary artery obstruction following a successful BASILICA procedure.


Assuntos
Estenose da Valva Aórtica , Parada Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Parada Cardíaca/etiologia , Idoso de 80 Anos ou mais , Doença Iatrogênica/prevenção & controle , Masculino , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/prevenção & controle , Bioprótese/efeitos adversos , Feminino , Angiografia Coronária
5.
Trials ; 25(1): 436, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38956681

RESUMO

BACKGROUND: Compared to traditional thoracotomy, transapical transcatheter aortic valve implantation (TAVI) surgery offers reduced trauma and faster recovery, fostering the adoption of enhanced recovery after surgery (ERAS) protocols in cardiac surgery. Despite these advancements, postoperative pain management has received insufficient attention. The potential effects of multi-mode analgesia, including ultrasound-guided serratus anterior plane block (SAPB), on postoperative pain and early quality of recovery have not been widely studied, lacking comprehensive prospective evidence. Therefore, this study aims to investigate the impact of SAPB combined with general anesthesia on early recovery quality and analgesic efficacy in transapical TAVI patients. METHODS: This prospective, randomized controlled study will enroll 70 patients undergoing transapical TAVI, randomly allocated to either the SAPB group or the control group. The primary outcome, assessed using Quality of Recovery-40 (QOR-40) scale, focuses on the quality of recovery at 24 h and 48 h postoperatively. Secondary outcomes include the visual analog scale (VAS) pain scores at rest and during coughing at 6 h, 12 h, 24 h, and 48 h after surgery, frequency of patient-controlled analgesia (PCA) utilization at 24 h and 48 h, opioid consumption at 24 h and 48 h, time and frequency of rescue analgesia and severe pain at 24 h and 48 h, incidence of nausea and vomiting at 48 h after surgery, and dosage of antiemetic drugs. DISCUSSION: The purpose of our study is to evaluate the effects of ultrasound-guided SAPB combined with general anesthesia on postoperative early quality of recovery and analgesia in transapical TAVI patients. The results obtained may provide valuable insight for the implementation of multi-mode analgesia and enhanced ERAS in this specific patient population. TRIAL REGISTRATION: China Clinical Trial Register ChiCTR2300068584. Registered on 24 February 2023.


Assuntos
Anestesia Geral , Bloqueio Nervoso , Dor Pós-Operatória , Substituição da Valva Aórtica Transcateter , Ultrassonografia de Intervenção , Humanos , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/prevenção & controle , Dor Pós-Operatória/diagnóstico , Bloqueio Nervoso/métodos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento , Analgesia Controlada pelo Paciente/métodos , Recuperação de Função Fisiológica , Masculino , Feminino , Fatores de Tempo , Medição da Dor , Idoso , China , Manejo da Dor/métodos
6.
Expert Rev Cardiovasc Ther ; 22(7): 325-337, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38970466

RESUMO

INTRODUCTION: Over the past two decades, transcatheter aortic valve replacement (TAVR) has expanded its application across all surgical risk levels, including low-risk patients, where, due to longer life expectancy, reducing common pitfalls of TAVR is essential. To address these needs, many technological advancements have been developed. Myval and the new generation Myval Octacor (Meril Life Sciences Pvt. Ltd) are novel balloon-expandable (BE) transcatheter heart valve (THV) systems designed for the treatment of severe aortic stenosis. AREAS COVERED: This review aims to illustrate the design features of these novel THVs and the main evidence from available studies. Furthermore, we provide evidence of these THVs' performance in challenging scenarios such as extra-large aortic annuli, bicuspid aortic valves, and valve-in-valve/valve-in-ring procedures. EXPERT OPINION: Myval and Myval Octacor have demonstrated comparable early safety and clinical efficacy to the leading contemporary THVs, exhibiting remarkably low rates of moderate to severe paravalvular leak (PVL) and permanent pacemaker implantation (PPI). The wide range of sizes offered by the Myval family may minimize the risk of under-/oversizing, potentially explaining the lower rates of the aforementioned phenomena. Moreover, the presence of both internal skirt and external reinforced cuff may also explain the low rate of moderate to severe PVL.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Índice de Gravidade de Doença , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem
8.
Int J Cardiol ; 411: 132243, 2024 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-38851542

RESUMO

INTRODUCTION: Patients with a small aortic annulus (SAA) undergoing aortic valve replacement are at increased risk of patient-prosthesis mismatch (PPM), which adversely affects outcomes. Transcatheter aortic valve replacement (TAVR) has shown promise in mitigating PPM compared to surgical aortic valve replacement (SAVR). METHODS: We conducted a systematic review and meta-analysis following PRISMA guidelines to compare clinical outcomes, mortality, and PPM between SAA patients undergoing TAVR and SAVR. Eligible studies were identified through comprehensive literature searches and assessed for quality and relevance. RESULTS: Nine studies with a total of 2476 patients were included. There was no significant difference in 30-day Mortality between TAVR vs SAVR groups (OR = 0.65, 95% CI [ 0.09-4.61], P = 0.22). There was no difference between both groups regarding myocardial infarction at 30 days (OR = 0.63, 95% CI [0.1-3.89], P = 0.62). TAVR was associated with a significantly lower 30-day major bleeding and 2-year major bleeding, Pooled studies were homogeneous (OR = 0.44, 95% CI [0.31-0.64], P < 0.01, I2 = 0, P = 0.89), (OR = 0.4 ,95% CI [0.21-0.77], P = 0.03, I2 = 0%, P = 0.62) respectively. TAVR was associated with a lower rate of moderate PPM (OR = 0.6, 95% CI [ 0.44-0.84], p value = 0.01, i2 = 0%, p value = 0.44). The overall effect estimate did not favor any of the two groups regarding short-term Mild AR (OR = 5.44, 95% CI [1.02-28.91], P = 0.05) and Moderate/severe AR (OR = 4.08, 95% CI [ 0.79-21.02], P = 0.08, I2 = 0%, P = 0.59). CONCLUSION: Our findings suggest that both TAVR and SAVR are viable options for treating AS in patients with a small aortic annulus. TAVR offers advantages in reducing PPM and major bleeding, while SAVR performs better in terms of pacemaker implantation. Future studies should focus on comparing newer generation TAVR techniques and devices with SAVR. Consideration of patient characteristics is crucial in selecting the optimal treatment approach for AS.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos
9.
BMC Anesthesiol ; 24(1): 209, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38907200

RESUMO

BACKGROUND: We used transcatheter aortic valve implantation (TAVI) procedure time to investigate the association between surgical team maturity and outcome. METHODS: Among patients who underwent TAVI between October 2015 and November 2019, those who had Sapien™ implanted with the transfemoral artery approach were included in the analysis. We used TAVI procedure time and surgery number to draw a learning curve. Then, we divided the patients into two groups before and after the number of cases where the sigmoid curve reaches a plateau. We compared the two groups regarding the surveyed factors and investigated the correlation between the TAVI procedure time and survey factors. RESULTS: Ninety-nine of 149 patients were analysed. The sigmoid curve had an inflection point in 23.2 cases and reached a plateau in 43.0 cases. Patients in the Late group had a shorter operating time, less contrast media, less radiation exposure, and less myocardial escape enzymes than the Early group. Surgical procedure time showed the strongest correlation with the surgical case number. CONCLUSION: The number of cases required for surgeon proficiency for isolated Sapien™ valve implantation was 43. This number may serve as a guideline for switching the anesthesia management of TAVI from general to local anesthesia.


Assuntos
Curva de Aprendizado , Duração da Cirurgia , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Masculino , Feminino , Idoso de 80 Anos ou mais , Idoso , Competência Clínica , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia
10.
Cardiol Clin ; 42(3): 333-338, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38910018

RESUMO

Patients with concomitant severe aortic stenosis and significant coronary artery disease present a diagnostic and therapeutic challenge in clinical practice. There are no clear-cut guidelines as to the timing of revascularization in these patients who are referred for transcatheter aortic valve replacement (TAVR). This article aims to show that in patients without high-grade proximal coronary artery disease, revascularization after TAVR is safe, feasible, and practical. Additionally, the use of preoperative TAVR computed tomographic angiography might be used in both intermediate and high-risk patients rather than invasive coronary angiography to assess for significant proximal coronary artery disease to help guide the timing of revascularization.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/diagnóstico , Angiografia Coronária , Revascularização Miocárdica/métodos , Intervenção Coronária Percutânea/métodos
11.
Cardiol Clin ; 42(3): 361-371, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38910021

RESUMO

Coronary artery obstruction is a rare complication of transcatheter aortic valve replacement (TAVR). This risk increases in TAVR-valve-in-valve procedure. Several anatomic risk factors were described in many studies to identify the predictive elements of coronary artery occlusion on computed tomography cardiac scan. Rescue percutaneous coronary intervention was the first approach described to treat this complication with a high mortality rate. Later on, preventive chimney stenting technique was evaluated and results showed that is a safe and effective strategy but it leads to a difficult coronary access later. New preventive techniques are being evaluated recently (Basilica and Shorctut).


Assuntos
Estenose da Valva Aórtica , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/efeitos adversos , Fatores de Risco , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia , Oclusão Coronária/cirurgia , Oclusão Coronária/diagnóstico , Oclusão Coronária/etiologia , Medição de Risco/métodos , Angiografia Coronária/métodos , Saúde Global
12.
Cardiol Clin ; 42(3): 373-387, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38910022

RESUMO

Self-expanding valves (SEV) and balloon-expandable valves (BEV) for transcatheter aortic valve implantation (TAVI) have their own features. There is a growing interest in long-term outcomes with the adoption of lifetime management in younger patients. To evaluate late outcomes in TAVI with SEV versus BEV, we performed a study-level meta-analysis of reconstructed time-to-event data published by May 31, 2023. We found no statistically significant difference in all-cause death after TAVI with SEV versus BEV. Randomized controlled trials are warranted to validate our results.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Tempo
14.
Eur J Cardiothorac Surg ; 66(1)2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38867365

RESUMO

OBJECTIVES: Limited data are available from randomized trials comparing outcomes between transcatheter aortic valve replacement (TAVR) and surgery in patients with different risks and with follow-up of at least 4 years or longer. In this large, population-based cohort study, long-term mortality and morbidity were investigated in patients undergoing aortic valve replacement (AVR) for severe aortic stenosis using a surgically implanted bioprosthesis (surgical/biological aortic valve replacement; sB-AVR) or TAVR. METHODS: Individual data from the Austrian Insurance Funds from 2010 through 2020 were analysed. The primary outcome was all-cause mortality, assessed in the overall and propensity score-matched populations. Secondary outcomes included reoperation and cardiovascular events. RESULTS: From January 2010 through December 2020, a total of 18 882 patients underwent sB-AVR (n = 11 749; 62.2%) or TAVR (n = 7133; 37.8%); median follow-up was 5.8 (95% CI 5.7-5.9) years (maximum 12.3 years). The risk of all-cause mortality was higher with TAVR compared with sB-AVR: hazard ratio 1.552, 95% confidence interval (CI) 1.469-1.640, P < 0.001; propensity score-matched hazard ratio 1.510, 1.403-1.625, P < 0.001. Estimated median survival was 8.8 years (95% CI 8.6-9.1) with sB-AVR versus 5 years (4.9-5.2) with TAVR. Estimated 5-year survival probability was 0.664 (0.664-0.686) with sB-AVR versus 0.409 (0.378-0.444) with TAVR overall, and 0.690 (0.674-0.707) and 0.560 (0.540-0.582), respectively, with propensity score matching. Separate subgroup analyses for patients aged 65-75 years and >75 years indicated a significant survival benefit in patients selected for sB-AVR in both groups. Other predictors of mortality were age, sex, previous heart failure, diabetes and chronic kidney disease. CONCLUSIONS: In this retrospective national population-based study, selection for TAVR was significantly associated with higher all-cause mortality compared with sB-AVR in patients ≥65 years with severe, symptomatic aortic stenosis in the >2-year follow-up.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Feminino , Masculino , Idoso , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Idoso de 80 Anos ou mais , Implante de Prótese de Valva Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Aórtica/cirurgia , Seleção de Pacientes , Estudos Retrospectivos , Pontuação de Propensão , Próteses Valvulares Cardíacas , Resultado do Tratamento , Bioprótese , Fatores de Risco , Seguimentos
15.
Korean J Radiol ; 25(7): 634-643, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38942457

RESUMO

OBJECTIVE: This study aimed to evaluate the diagnostic efficacy and safety of low-contrast-dose, dual-source dual-energy CT before transcatheter aortic valve replacement (TAVR) in patients with compromised renal function. MATERIALS AND METHODS: A total of 54 consecutive patients (female:male, 26:38; 81.9 ± 7.3 years) with reduced renal function underwent pre-TAVR dual-energy CT with a 30-mL contrast agent between June 2022 and March 2023. Monochromatic (40- and 50-keV) and conventional (120-kVp) images were reconstructed and analyzed. The subjective quality score, vascular attenuation, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were compared among the imaging techniques using the Friedman test and post-hoc analysis. Interobserver reliability for aortic annular measurement was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. The procedural outcomes and incidence of post-contrast acute kidney injury (AKI) were assessed. RESULTS: Monochromatic images achieved diagnostic quality in all patients. The 50-keV images achieved superior vascular attenuation and CNR (P < 0.001 in all) while maintaining a similar SNR compared to conventional CT. For aortic annular measurement, the 50-keV images showed higher interobserver reliability compared to conventional CT: ICC, 0.98 vs. 0.90 for area and 0.97 vs. 0.95 for perimeter; 95% limits of agreement width, 0.63 cm² vs. 0.92 cm² for area and 5.78 mm vs. 8.50 mm for perimeter. The size of the implanted device matched CT-measured values in all patients, achieving a procedural success rate of 92.6%. No patient experienced a serum creatinine increase of ≥ 1.5 times baseline in the 48-72 hours following CT. However, one patient had a procedural delay due to gradual renal function deterioration. CONCLUSION: Low-contrast-dose imaging with 50-keV reconstruction enables precise pre-TAVR evaluation with improved image quality and minimal risk of post-contrast AKI. This approach may be an effective and safe option for pre-TAVR evaluation in patients with compromised renal function.


Assuntos
Meios de Contraste , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Idoso , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Doses de Radiação , Reprodutibilidade dos Testes , Insuficiência Renal , Estudos Retrospectivos , Razão Sinal-Ruído
16.
JMIR Mhealth Uhealth ; 12: e53964, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38832585

RESUMO

Background: Due to aging of the population, the prevalence of aortic valve stenosis will increase drastically in upcoming years. Consequently, transcatheter aortic valve implantation (TAVI) procedures will also expand worldwide. Optimal selection of patients who benefit with improved symptoms and prognoses is key, since TAVI is not without its risks. Currently, we are not able to adequately predict functional outcomes after TAVI. Quality of life measurement tools and traditional functional assessment tests do not always agree and can depend on factors unrelated to heart disease. Activity tracking using wearable devices might provide a more comprehensive assessment. Objective: This study aimed to identify objective parameters (eg, change in heart rate) associated with improvement after TAVI for severe aortic stenosis from a wearable device. Methods: In total, 100 patients undergoing routine TAVI wore a Philips Health Watch device for 1 week before and after the procedure. Watch data were analyzed offline-before TAVI for 97 patients and after TAVI for 75 patients. Results: Parameters such as the total number of steps and activity time did not change, in contrast to improvements in the 6-minute walking test (6MWT) and physical limitation domain of the transformed WHOQOL-BREF questionnaire. Conclusions: These findings, in an older TAVI population, show that watch-based parameters, such as the number of steps, do not change after TAVI, unlike traditional 6MWT and QoL assessments. Basic wearable device parameters might be less appropriate for measuring treatment effects from TAVI.


Assuntos
Substituição da Valva Aórtica Transcateter , Dispositivos Eletrônicos Vestíveis , Humanos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Feminino , Estudos Prospectivos , Dispositivos Eletrônicos Vestíveis/estatística & dados numéricos , Dispositivos Eletrônicos Vestíveis/normas , Idoso de 80 Anos ou mais , Idoso , Estenose da Valva Aórtica/cirurgia , Inquéritos e Questionários , Qualidade de Vida/psicologia
18.
EuroIntervention ; 20(12): e770-e780, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38887883

RESUMO

BACKGROUND: Coronary access (CA) is a major concern in redo-transcatheter aortic valve implantation (TAVI) for failing supra-annular self-expanding transcatheter aortic valves (TAVs). AIMS: This ex vivo study evaluated the benefit of leaflet splitting (LS) on subsequent CA after redo-TAVI in anatomies deemed at high risk of unfeasible CA. METHODS: Ex vivo, patient-specific models were printed three-dimensionally. Index TAVI was performed using ACURATE neo2 or Evolut PRO (TAV-1) at the standard implant depth and with different degrees of commissural misalignment (CMA). Redo-TAVI was performed using the balloon-expandable SAPIEN 3 Ultra (TAV-2) at different implant depths with commissural alignment. Selective CA was attempted for each configuration before and after LS in a pulsatile flow simulator. The leaflet splay area was assessed on the bench. RESULTS: In matched comparisons of 128 coronary cannulations across 64 redo-TAVI configurations, the overall feasibility of CA significantly increased after LS (60.9% vs 18.7%; p<0.001). The effect of LS varied according to the sinotubular junction height, TAV-1 design, TAV-1 CMA, and TAV-2 implant depth, given TAV-2 alignment. LS enabled CA for up to CMA 45° with the ACURATE neo2 TAV-1 and up to CMA 30° with the Evolut PRO TAV-1. The combination of LS and a low TAV-2 implant provided the highest feasibility of CA after redo-TAVI. The leaflet splay area ranged from 25.60 mm2 to 37.86 mm2 depending on the TAV-1 platform and TAV-2 implant depth. CONCLUSIONS: In high-risk anatomies, LS significantly improves CA feasibility after redo-TAVI for degenerated supra-annular self-expanding platforms. Decisions on redo-TAVI feasibility should be carefully individualised, taking into account the expected benefit of LS on CA for each scenario.


Assuntos
Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/instrumentação , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Impressão Tridimensional , Estenose da Valva Aórtica/cirurgia , Vasos Coronários/cirurgia , Falha de Prótese , Reoperação