1.
Magn Reson Med ; 92(2): 519-531, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38623901

RESUMEN

PURPOSE: Diffusion-weighted (DW) imaging provides a useful clinical contrast, but is susceptible to motion-induced dephasing caused by the application of strong diffusion gradients. Phase navigators are commonly used to resolve shot-to-shot motion-induced phase in multishot reconstructions, but poor phase estimates result in signal dropout and Apparent Diffusion Coefficient (ADC) overestimation. These artifacts are prominent in the abdomen, a region prone to involuntary cardiac and respiratory motion. To improve the robustness of DW imaging in the abdomen, region-based shot rejection schemes that selectively weight regions where the shot-to-shot phase is poorly estimated were evaluated. METHODS: Spatially varying weights for each shot, reflecting both the accuracy of the estimated phase and the degree of subvoxel dephasing, were estimated from the phase navigator magnitude images. The weighting was integrated into a multishot reconstruction using different formulations and phase navigator resolutions and tested with different phase navigator resolutions in multishot DW-echo Planar Imaging acquisitions of the liver and pancreas, using conventional monopolar and velocity-compensated diffusion encoding. Reconstructed images and ADC estimates were compared qualitatively. RESULTS: The proposed region-based shot rejection reduces banding and signal dropout artifacts caused by physiological motion in the liver and pancreas. Shot rejection allows conventional monopolar diffusion encoding to achieve median ADCs in the pancreas comparable to motion-compensated diffusion encoding, albeit with a greater spread of ADCs. CONCLUSION: Region-based shot rejection is a linear reconstruction that improves the motion robustness of multi-shot DWI and requires no sequence modifications.


Asunto(s)
Abdomen , Algoritmos , Artefactos , Imagen de Difusión por Resonancia Magnética , Humanos , Imagen de Difusión por Resonancia Magnética/métodos , Abdomen/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Páncreas/diagnóstico por imagen , Hígado/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Reproducibilidad de los Resultados , Movimiento (Física) , Imagen Eco-Planar/métodos , Aumento de la Imagen/métodos , Adulto
2.
Magn Reson Med ; 92(6): 2358-2372, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38997797

RESUMEN

PURPOSE: Comprehensive assessment of image quality requires accounting for spatial variations in (i) intensity artifact, (ii) geometric distortion, (iii) signal-to-noise ratio (SNR), and (iv) spatial resolution, among other factors. This work presents an ensemble of methods to meet this need, from phantom design to image analysis, and applies it to the scenario of imaging near metal. METHODS: A modular phantom design employing a gyroid lattice is developed to enable the co-registered volumetric quantitation of image quality near a metallic hip implant. A method for measuring spatial resolution by means of local point spread function (PSF) estimation is presented and the relative fitness of gyroid and cubic lattices is examined. Intensity artifact, geometric distortion, and SNR maps are also computed. Results are demonstrated with 2D-FSE and MAVRIC-SL scan protocols on a 3T MRI scanner. RESULTS: The spatial resolution method demonstrates a worst-case error of 0.17 pixels for measuring in-plane blurring up to 3 pixels (full width at half maximum). The gyroid outperforms a cubic lattice design for the local PSF estimation task. The phantom supports four configurations toggling the presence/absence of both metal and structure with good spatial correspondence for co-registered analysis of the four quality factors. The marginal scan time to evaluate one scan protocol amounts to five repetitions. The phantom design can be fabricated in 2 days at negligible material cost. CONCLUSION: The phantom and associated analysis methods can elucidate complex image quality trade-offs involving intensity artifact, geometric distortion, SNR, and spatial resolution. The ensemble of methods is suitable for benchmarking imaging performance near metal.


Asunto(s)
Artefactos , Imagen por Resonancia Magnética , Metales , Fantasmas de Imagen , Imagen por Resonancia Magnética/métodos , Algoritmos , Humanos , Relación Señal-Ruido , Reproducibilidad de los Resultados , Aumento de la Imagen/métodos , Sensibilidad y Especificidad , Interpretación de Imagen Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador/métodos
3.
Magn Reson Med ; 92(6): 2343-2357, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-39051729

RESUMEN

PURPOSE: Diffusion-weighted imaging (DWI) suffers from geometric distortion and chemical shift artifacts due to the commonly used Echo Planar Imaging (EPI) trajectory. Even with fat suppression in DWI, severe B0 and B1 variations can result in residual fat, which becomes both a source of image artifacts and a confounding factor in diffusion-weighted contrast in distinguishing benign and malignant tissues. This work presents a method for acquiring distortion-free diffusion-weighted images using spatiotemporal acquisition and joint reconstruction. Water-fat separation is performed by chemical-shift encoding. METHODS: Spatiotemporal acquisition is employed to obtain distortion-free images at a series of echo times. Chemical-shift encoding is used for water-fat separation. Reconstruction and separation are performed jointly in the spat-spectral domain. To address the shot-to-shot motion-induced phase in DWI, an Fast Spin Echo (FSE)-based phase navigator is incorporated into the sequence to obtain distortion-free phase information. The proposed method was validated in phantoms and in vivo for the brain, head and neck, and breast. RESULTS: The proposed method enables the acquisition of distortion-free diffusion-weighted images in the presence of B0 field inhomogenieties commonly observed in the body. Water and fat components are separated with no obvious spectral leakage artifacts. The estimated Apparent Diffusion Coefficient (ADC) is comparable to that of multishot DW-EPI. CONCLUSION: Distortion-free, water-fat separated diffusion-weighted images in body can be obtained through the utilization of spatiotemporal acquisition and joint reconstruction methods.


Asunto(s)
Tejido Adiposo , Algoritmos , Artefactos , Encéfalo , Imagen de Difusión por Resonancia Magnética , Imagen Eco-Planar , Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen , Imagen de Difusión por Resonancia Magnética/métodos , Humanos , Tejido Adiposo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen Eco-Planar/métodos , Femenino , Encéfalo/diagnóstico por imagen , Agua/química , Mama/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Cabeza/diagnóstico por imagen
4.
Magn Reson Med ; 2024 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-39221478

RESUMEN

PURPOSE: To enable diffusion weighted imaging in prostate patients with metallic total hip replacements in clinically feasible scan times for prostate cancer screening, and avoid distortion and dropout artifacts present in the conventionally used Echo Planar Imaging (EPI). METHODS: A reduced field of view (FOV) diffusion-prepared sequence that is robust to the B 0 $$ {\kern0em }_0 $$ inhomogeneities produced by total hip replacements was achieved using high radiofrequency (RF) bandwidth pulses and manipulation for stimulated echo pathways. The reduced FOV along the A/P direction was obtained using slice-select gradient reversal, and the prepared magnetization was imaged with a three-dimensional RF-spoiled gradient echo readout. The sequence was validated in phantom experiments, in vivo in healthy volunteers with and without total hip replacements, and in vivo in patients undergoing a standard MRI prostate exam. RESULTS: The proposed sequence is robust to shading and distortion artifacts that are encountered by standard diffusion-weighted EPI in the presence of moderate off-resonance. Apparent diffusion coefficient estimates obtained by the proposed sequence were comparable to those obtained with diffusion-weighted EPI. CONCLUSION: Acquisition of distortionless diffusion weighted images of the prostate is feasible in patients with total hip replacements on conventional, whole-body 3T MRI, using a b-value of 800 s / mm 2 $$ \mathrm{s}/{\mathrm{mm}}^2 $$ and nominal resolution of 1.7 × $$ \times $$ 1.7 × $$ \times $$ 4 mm3 in scan times of 6 min.

5.
Magn Reson Med ; 92(2): 586-604, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38688875

RESUMEN

PURPOSE: Abdominal imaging is frequently performed with breath holds or respiratory triggering to reduce the effects of respiratory motion. Diffusion weighted sequences provide a useful clinical contrast but have prolonged scan times due to low signal-to-noise ratio (SNR), and cannot be completed in a single breath hold. Echo-planar imaging (EPI) is the most commonly used trajectory for diffusion weighted imaging but it is susceptible to off-resonance artifacts. A respiratory resolved, three-dimensional (3D) diffusion prepared sequence that obtains distortionless diffusion weighted images during free-breathing is presented. Techniques to address the myriad of challenges including: 3D shot-to-shot phase correction, respiratory binning, diffusion encoding during free-breathing, and robustness to off-resonance are described. METHODS: A twice-refocused, M1-nulled diffusion preparation was combined with an RF-spoiled gradient echo readout and respiratory resolved reconstruction to obtain free-breathing diffusion weighted images in the abdomen. Cartesian sampling permits a sampling density that enables 3D shot-to-shot phase navigation and reduction of transient fat artifacts. Theoretical properties of a region-based shot rejection are described. The region-based shot rejection method was evaluated with free-breathing (normal and exaggerated breathing), and respiratory triggering. The proposed sequence was compared in vivo with multishot DW-EPI. RESULTS: The proposed sequence exhibits no evident distortion in vivo when compared to multishot DW-EPI, robustness to B0 and B1 field inhomogeneities, and robustness to motion from different respiratory patterns. CONCLUSION: Acquisition of distortionless, diffusion weighted images is feasible during free-breathing with a b-value of 500 s/mm2, scan time of 6 min, and a clinically viable reconstruction time.


Asunto(s)
Abdomen , Artefactos , Imagen de Difusión por Resonancia Magnética , Imagenología Tridimensional , Humanos , Imagen de Difusión por Resonancia Magnética/métodos , Abdomen/diagnóstico por imagen , Imagenología Tridimensional/métodos , Respiración , Algoritmos , Relación Señal-Ruido , Reproducibilidad de los Resultados , Interpretación de Imagen Asistida por Computador/métodos
6.
J Magn Reson Imaging ; 2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38703134

RESUMEN

BACKGROUND: Cartilage T2 can detect joints at risk of developing osteoarthritis. The quantitative double-echo steady state (qDESS) sequence is attractive for knee cartilage T2 mapping because of its acquisition time of under 5 minutes. Understanding the reproducibility errors associated with qDESS T2 is essential to profiling the technical performance of this biomarker. PURPOSE: To examine the combined acquisition and segmentation reproducibility of knee cartilage qDESS T2 using two different regional analysis schemes: 1) manual segmentation of subregions loaded during common activities and 2) automatic subregional segmentation. STUDY TYPE: Prospective. SUBJECTS: 11 uninjured participants (age: 28 ± 3 years; 8 (73%) female). FIELD STRENGTH/SEQUENCE: 3-T, qDESS. ASSESSMENT: Test-retest T2 maps were acquired twice on the same day and with a 1-week interval between scans. For each acquisition, average cartilage T2 was calculated in four manually segmented regions encompassing tibiofemoral contact areas during common activities and 12 automatically segmented regions from the deep-learning open-source framework for musculoskeletal MRI analysis (DOSMA) encompassing medial and lateral anterior, central, and posterior tibiofemoral regions. Test-retest T2 values from matching regions were used to evaluate reproducibility. STATISTICAL TESTS: Coefficients of variation (%CV), root-mean-square-average-CV (%RMSA-CV), and intraclass correlation coefficients (ICCs) assessed test-retest T2 reproducibility. The median of test-retest standard deviations was used for T2 precision. Bland-Altman (BA) analyses examined test-retest biases. The smallest detectable difference (SDD) was defined as the BA limit of agreement of largest magnitude. Significance was accepted for P < 0.05. RESULTS: All cartilage regions across both segmentation schemes demonstrated intraday and interday qDESS T2 CVs and RMSA-CVs of ≤5%. T2 ICC values >0.75 were observed in the majority of regions but were more variable in interday tibial comparisons. Test-retest T2 precision was <1.3 msec. The T2 SDD was 3.8 msec. DATA CONCLUSION: Excellent CV and RMSA-CV reproducibility may suggest that qDESS T2 increases or decreases >5% (3.8 msec) could represent changes to cartilage composition. TECHNICAL EFFICACY: Stage 2.

7.
Magn Reson Med ; 89(2): 577-593, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36161727

RESUMEN

PURPOSE: To develop and validate a method for B 0 $$ {B}_0 $$ mapping for knee imaging using the quantitative Double-Echo in Steady-State (qDESS) exploiting the phase difference ( Δ Î¸ $$ \Delta \theta $$ ) between the two echoes acquired. Contrary to a two-gradient-echo (2-GRE) method, Δ Î¸ $$ \Delta \theta $$ depends only on the first echo time. METHODS: Bloch simulations were applied to investigate robustness to noise of the proposed methodology and all imaging studies were validated with phantoms and in vivo simultaneous bilateral knee acquisitions. Two phantoms and five healthy subjects were scanned using qDESS, water saturation shift referencing (WASSR), and multi-GRE sequences. Δ B 0 $$ \Delta {B}_0 $$ maps were calculated with the qDESS and the 2-GRE methods and compared against those obtained with WASSR. The comparison was quantitatively assessed exploiting pixel-wise difference maps, Bland-Altman (BA) analysis, and Lin's concordance coefficient ( ρ c $$ {\rho}_c $$ ). For in vivo subjects, the comparison was assessed in cartilage using average values in six subregions. RESULTS: The proposed method for measuring Δ B 0 $$ \Delta {B}_0 $$ inhomogeneities from a qDESS acquisition provided Δ B 0 $$ \Delta {B}_0 $$ maps that were in good agreement with those obtained using WASSR. Δ B 0 $$ \Delta {B}_0 $$ ρ c $$ {\rho}_c $$ values were ≥ $$ \ge $$ 0.98 and 0.90 in phantoms and in vivo, respectively. The agreement between qDESS and WASSR was comparable to that of a 2-GRE method. CONCLUSION: The proposed method may allow B0 correction for qDESS T 2 $$ {T}_2 $$ mapping using an inherently co-registered Δ B 0 $$ \Delta {B}_0 $$ map without requiring an additional B0 measurement sequence. More generally, the method may help shorten knee imaging protocols that require an auxiliary Δ B 0 $$ \Delta {B}_0 $$ map by exploiting a qDESS acquisition that also provides T 2 $$ {T}_2 $$ measurements and high-quality morphological imaging.


Asunto(s)
Rodilla , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Rodilla/diagnóstico por imagen , Articulación de la Rodilla/diagnóstico por imagen , Agua
8.
Magn Reson Med ; 90(5): 2052-2070, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37427449

RESUMEN

PURPOSE: To develop a method for building MRI reconstruction neural networks robust to changes in signal-to-noise ratio (SNR) and trainable with a limited number of fully sampled scans. METHODS: We propose Noise2Recon, a consistency training method for SNR-robust accelerated MRI reconstruction that can use both fully sampled (labeled) and undersampled (unlabeled) scans. Noise2Recon uses unlabeled data by enforcing consistency between model reconstructions of undersampled scans and their noise-augmented counterparts. Noise2Recon was compared to compressed sensing and both supervised and self-supervised deep learning baselines. Experiments were conducted using retrospectively accelerated data from the mridata three-dimensional fast-spin-echo knee and two-dimensional fastMRI brain datasets. All methods were evaluated in label-limited settings and among out-of-distribution (OOD) shifts, including changes in SNR, acceleration factors, and datasets. An extensive ablation study was conducted to characterize the sensitivity of Noise2Recon to hyperparameter choices. RESULTS: In label-limited settings, Noise2Recon achieved better structural similarity, peak signal-to-noise ratio, and normalized-RMS error than all baselines and matched performance of supervised models, which were trained with 14 × $$ 14\times $$ more fully sampled scans. Noise2Recon outperformed all baselines, including state-of-the-art fine-tuning and augmentation techniques, among low-SNR scans and when generalizing to OOD acceleration factors. Augmentation extent and loss weighting hyperparameters had negligible impact on Noise2Recon compared to supervised methods, which may indicate increased training stability. CONCLUSION: Noise2Recon is a label-efficient reconstruction method that is robust to distribution shifts, such as changes in SNR, acceleration factors, and others, with limited or no fully sampled training data.


Asunto(s)
Aprendizaje Profundo , Procesamiento de Imagen Asistido por Computador , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Relación Señal-Ruido , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Aprendizaje Automático Supervisado
9.
J Magn Reson Imaging ; 58(3): 951-962, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-36583628

RESUMEN

BACKGROUND: Diffusion-weighted imaging (DWI) may allow for breast cancer screening MRI without a contrast injection. Multishot methods improve prone DWI of the breasts but face different challenges in the supine position. PURPOSE: To establish a multishot DWI (msDWI) protocol for supine breast MRI and to evaluate the performance of supine vs. prone msDWI. STUDY TYPE: Prospective. POPULATION: Protocol optimization: 10 healthy women (ages 22-56), supine vs. prone: 24 healthy women (ages 22-62) and five women (ages 29-61) with breast tumors. FIELD STRENGTH/SEQUENCE: 3-T, protocol optimization msDWI: free-breathing (FB) 2-shots, FB 4-shots, respiratory-triggered (RT) 2-shots, RT 4-shots, supine vs. prone: RT 4-shot msDWI, T2-weighted fast-spin echo. ASSESSMENT: Protocol optimization and supine vs. prone: three observers performed an image quality assessment of sharpness, aliasing, distortion (vs. T2), perceived SNR, and overall image quality (scale of 1-5). Apparent diffusion coefficients (ADCs) in fibroglandular tissue (FGT) and breast tumors were measured. STATISTICAL TESTS: Effect of study variables on dichotomized ratings (4/5 vs. 1/2/3) and FGT ADCs were assessed with mixed-effects logistic regression. Interobserver agreement utilized Gwet's agreement coefficient (AC). Lesion ADCs were assessed by Bland-Altman analysis and concordance correlation (ρc ). P value <0.05 was considered statistically significant. RESULTS: Protocol optimization: 4-shots significantly improved sharpness and distortion; RT significantly improved sharpness, aliasing, perceived SNR, and overall image quality. FGT ADCs were not significantly different between shots (P = 0.812), FB vs. RT (P = 0.591), or side (P = 0.574). Supine vs. prone: supine images were rated significantly higher for sharpness, aliasing, and overall image quality. FGT ADCs were significantly higher supine; lesion ADCs were highly correlated (ρc  = 0.92). DATA CONCLUSION: Based on image quality, supine msDWI outperformed prone msDWI. Lesion ADCs were highly correlated between the two positions, while FGT ADCs were higher in the supine position. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 1.


Asunto(s)
Neoplasias de la Mama , Imagen de Difusión por Resonancia Magnética , Humanos , Femenino , Estudios Prospectivos , Posición Prona , Imagen de Difusión por Resonancia Magnética/métodos , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados , Neoplasias de la Mama/diagnóstico por imagen , Imagen Eco-Planar/métodos
10.
J Magn Reson Imaging ; 57(4): 1029-1039, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-35852498

RESUMEN

BACKGROUND: Deep learning (DL)-based automatic segmentation models can expedite manual segmentation yet require resource-intensive fine-tuning before deployment on new datasets. The generalizability of DL methods to new datasets without fine-tuning is not well characterized. PURPOSE: Evaluate the generalizability of DL-based models by deploying pretrained models on independent datasets varying by MR scanner, acquisition parameters, and subject population. STUDY TYPE: Retrospective based on prospectively acquired data. POPULATION: Overall test dataset: 59 subjects (26 females); Study 1: 5 healthy subjects (zero females), Study 2: 8 healthy subjects (eight females), Study 3: 10 subjects with osteoarthritis (eight females), Study 4: 36 subjects with various knee pathology (10 females). FIELD STRENGTH/SEQUENCE: A 3-T, quantitative double-echo steady state (qDESS). ASSESSMENT: Four annotators manually segmented knee cartilage. Each reader segmented one of four qDESS datasets in the test dataset. Two DL models, one trained on qDESS data and another on Osteoarthritis Initiative (OAI)-DESS data, were assessed. Manual and automatic segmentations were compared by quantifying variations in segmentation accuracy, volume, and T2 relaxation times for superficial and deep cartilage. STATISTICAL TESTS: Dice similarity coefficient (DSC) for segmentation accuracy. Lin's concordance correlation coefficient (CCC), Wilcoxon rank-sum tests, root-mean-squared error-coefficient-of-variation to quantify manual vs. automatic T2 and volume variations. Bland-Altman plots for manual vs. automatic T2 agreement. A P value < 0.05 was considered statistically significant. RESULTS: DSCs for the qDESS-trained model, 0.79-0.93, were higher than those for the OAI-DESS-trained model, 0.59-0.79. T2 and volume CCCs for the qDESS-trained model, 0.75-0.98 and 0.47-0.95, were higher than respective CCCs for the OAI-DESS-trained model, 0.35-0.90 and 0.13-0.84. Bland-Altman 95% limits of agreement for superficial and deep cartilage T2 were lower for the qDESS-trained model, ±2.4 msec and ±4.0 msec, than the OAI-DESS-trained model, ±4.4 msec and ±5.2 msec. DATA CONCLUSION: The qDESS-trained model may generalize well to independent qDESS datasets regardless of MR scanner, acquisition parameters, and subject population. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 1.


Asunto(s)
Cartílago Articular , Aprendizaje Profundo , Osteoartritis de la Rodilla , Femenino , Humanos , Estudios Retrospectivos , Cartílago Articular/patología , Imagen por Resonancia Magnética/métodos , Algoritmos , Osteoartritis de la Rodilla/patología
11.
Magn Reson Med ; 88(5): 2139-2156, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35906924

RESUMEN

PURPOSE: Diffusion weighted Fast Spin Echo (DW-FSE) is a promising approach for distortionless DW imaging that is robust to system imperfections such as eddy currents and off-resonance. Due to non-Carr-Purcell-Meiboom-Gill (CPMG) magnetization, most DW-FSE sequences discard a large fraction of the signal ( 2 - 2 × $$ \sqrt{2}-2\times $$ ), reducing signal-to-noise ratio (SNR) efficiency compared to DW-EPI. The full FSE signal can be preserved by quadratically incrementing the transmit phase of the refocusing pulses, but this method of resolving non-CPMG magnetization has only been applied to single-shot DW-FSE due to challenges associated with image reconstruction. We present a joint linear reconstruction for multishot quadratic phase increment data that addresses these challenges and corrects ghosting from both shot-to-shot phase and intrashot signal oscillations. Multishot imaging reduces T2 blur and joint reconstruction of shots improves g-factor performance. A thorough analysis on the condition number of the proposed linear system is described. METHODS: A joint multishot reconstruction is derived from the non-CPMG signal model. Multishot quadratic phase increment DW-FSE was tested in a standardized diffusion phantom and compared to single-shot DW-FSE and DW-EPI in vivo in the brain, cervical spine, and prostate. The pseudo multiple replica technique was applied to generate g-factor and SNR maps. RESULTS: The proposed joint shot reconstruction eliminates ghosting from shot-to-shot phase and intrashot oscillations. g-factor performance is improved compared to previously proposed reconstructions, permitting efficient multishot imaging. apparent diffusion coefficient estimates in phantom experiments and in vivo are comparable to those obtained with conventional methods. CONCLUSION: Multi-shot non-CPMG DW-FSE data with full signal can be jointly reconstructed using a linear model.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Branquias , Animales , Imagen de Difusión por Resonancia Magnética/métodos , Imagen Eco-Planar/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Fantasmas de Imagen , Relación Señal-Ruido
12.
Magn Reson Med ; 87(6): 2650-2666, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35014729

RESUMEN

PURPOSE: DWI near metal implants has not been widely explored due to substantial challenges associated with through-slice and in-plane distortions, the increased encoding requirement of different spectral bins, and limited SNR. There is no widely adopted clinical protocol for DWI near metal since the commonly used EPI trajectory fails completely due to distortion from extreme off-resonance ranging from 2 to 20 kHz. We present a sequence that achieves DWI near metal with moderate b-values (400-500 s/mm2 ) and volumetric coverage in clinically feasible scan times. THEORY AND METHODS: Multispectral excitation with Cartesian sampling, view angle tilting, and kz phase encoding reduce in-plane and through-plane off-resonance artifacts, and Carr-Purcell-Meiboom-Gill (CPMG) spin-echo refocusing trains counteract T2* effects. The effect of random phase on the refocusing train is eliminated using a stimulated echo diffusion preparation. Root-flipped Shinnar-Le Roux refocusing pulses permits preparation of a high spectral bandwidth, which improves imaging times by reducing the number of excitations required to cover the desired spectral range. B1 sensitivity is reduced by using an excitation that satisfies the CPMG condition in the preparation. A method for ADC quantification insensitive to background gradients is presented. RESULTS: Non-linear phase refocusing pulses reduces the peak B1 by 46% which allows RF bandwidth to be doubled. Simulations and phantom experiments show that a non-linear phase CPMG pulse pair reduces B1 sensitivity. Application in vivo demonstrates complementary contrast to conventional multispectral acquisitions and improved visualization compared to DW-EPI. CONCLUSION: Volumetric and multispectral DW imaging near metal can be achieved with a 3D encoded sequence.


Asunto(s)
Artefactos , Branquias , Animales , Imagen de Difusión por Resonancia Magnética/métodos , Fantasmas de Imagen , Prótesis e Implantes
13.
NMR Biomed ; 35(4): e4670, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35088466

RESUMEN

Magnetic resonance fingerprinting (MRF) is a rapidly developing approach for fast quantitative MRI. A typical drawback of dictionary-based MRF is an explosion of the dictionary size as a function of the number of reconstructed parameters, according to the "curse of dimensionality", which determines an explosion of resource requirements. Neural networks (NNs) have been proposed as a feasible alternative, but this approach is still in its infancy. In this work, we design a deep learning approach to MRF using a fully connected network (FCN). In the first part we investigate, by means of simulations, how the NN performance scales with the number of parameters to be retrieved in comparison with the standard dictionary approach. Four MRF sequences were considered: IR-FISP, bSSFP, IR-FISP-B1 , and IR-bSSFP-B1 , the latter two designed to be more specific for B1+ parameter encoding. Estimation accuracy, memory usage, and computational time required to perform the estimation task were considered to compare the scalability capabilities of the dictionary-based and the NN approaches. In the second part we study optimal training procedures by including different data augmentation and preprocessing strategies during training to achieve better accuracy and robustness to noise and undersampling artifacts. The study is conducted using the IR-FISP MRF sequence exploiting both simulations and in vivo acquisitions. Results demonstrate that the NN approach outperforms the dictionary-based approach in terms of scalability capabilities. Results also allow us to heuristically determine the optimal training strategy to make an FCN able to predict T1 , T2 , and M0 maps that are in good agreement with those obtained with the original dictionary approach. k-SVD denoising is proposed and found to be critical as a preprocessing step to handle undersampled data.


Asunto(s)
Aprendizaje Profundo , Algoritmos , Encéfalo , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética , Fantasmas de Imagen
14.
Skeletal Radiol ; 51(3): 549-556, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34223946

RESUMEN

OBJECTIVE: To compare the diagnostic performance of a conventional metal artifact suppression sequence MAVRIC-SL (multi-acquisition variable-resonance image combination selective) and a novel 2.6-fold faster sequence employing robust principal component analysis (RPCA), in the MR evaluation of hip implants at 3 T. MATERIALS AND METHODS: Thirty-six total hip implants in 25 patients were scanned at 3 T using a conventional MAVRIC-SL proton density-weighted sequence and an RPCA MAVRIC-SL proton density-weighted sequence. Comparison was made of image quality, geometric distortion, visualization around acetabular and femoral components, and conspicuity of abnormal imaging findings using the Wilcoxon signed-rank test and a non-inferiority test. Abnormal findings were correlated with subsequent clinical management and intraoperative findings if the patient underwent subsequent surgery. RESULTS: Mean scores for conventional MAVRIC-SL were better than RPCA MAVRIC-SL for all qualitative parameters (p < 0.05), although the probability of RPCA MAVRIC-SL being clinically useful was non-inferior to conventional MAVRIC-SL (within our accepted 10% difference, p < 0.05), except for visualization around the acetabular component. Abnormal imaging findings were seen in 25 hips, and either equally visible or visible but less conspicuous on RPCA MAVRIC-SL in 21 out of 25 cases. In 4 cases, a small joint effusion was queried on MAVRIC-SL but not RPCA MAVRIC-SL, but the presence or absence of a small effusion did not affect subsequent clinical management and patient outcome. CONCLUSION: While the overall image quality is reduced, RPCA MAVRIC-SL allows for significantly reduced scan time and maintains almost equal diagnostic performance.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artefactos , Humanos , Imagen por Resonancia Magnética , Prótesis e Implantes
15.
Magn Reson Med ; 85(2): 709-720, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32783339

RESUMEN

PURPOSE: To accelerate and improve multishot diffusion-weighted MRI reconstruction using deep learning. METHODS: An unrolled pipeline containing recurrences of model-based gradient updates and neural networks was introduced for accelerating multishot DWI reconstruction with shot-to-shot phase correction. The network was trained to predict results of jointly reconstructed multidirection data using single-direction data as input. In vivo brain and breast experiments were performed for evaluation. RESULTS: The proposed method achieves a reconstruction time of 0.1 second per image, over 100-fold faster than a shot locally low-rank reconstruction. The resultant image quality is comparable to the target from the joint reconstruction with a peak signal-to-noise ratio of 35.3 dB, a normalized root-mean-square error of 0.0177, and a structural similarity index of 0.944. The proposed method also improves upon the locally low-rank reconstruction (2.9 dB higher peak signal-to-noise ratio, 29% lower normalized root-mean-square error, and 0.037 higher structural similarity index). With training data from the brain, this method also generalizes well to breast diffusion-weighted imaging, and fine-tuning further reduces aliasing artifacts. CONCLUSION: A proposed data-driven approach enables almost real-time reconstruction with improved image quality, which improves the feasibility of multishot DWI in a wide range of clinical and neuroscientific studies.


Asunto(s)
Algoritmos , Imagen de Difusión por Resonancia Magnética , Artefactos , Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador , Reproducibilidad de los Resultados
16.
J Magn Reson Imaging ; 53(3): 807-817, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33067849

RESUMEN

BACKGROUND: Diffusion-weighted imaging (DWI) has shown promise to screen for breast cancer without a contrast injection, but image distortion and low spatial resolution limit standard single-shot DWI. Multishot DWI methods address these limitations but introduce shot-to-shot phase variations requiring correction during reconstruction. PURPOSE: To investigate the performance of two multishot DWI reconstruction methods, multiplexed sensitivity encoding (MUSE) and shot locally low-rank (shot-LLR), compared to single-shot DWI in the breast. STUDY TYPE: Prospective. POPULATION: A total of 45 women who consented to have multishot DWI added to a clinically indicated breast MRI. FIELD STRENGTH/SEQUENCES: Single-shot DWI reconstructed by parallel imaging, multishot DWI with four or eight shots reconstructed by MUSE and shot-LLR, 3D T2 -weighted imaging, and contrast-enhanced MRI at 3T. ASSESSMENT: Three blinded observers scored images for 1) general image quality (perceived signal-to-noise ratio [SNR], ghosting, distortion), 2) lesion features (discernment and morphology), and 3) perceived resolution. Apparent diffusion coefficient (ADC) of the lesion was also measured and compared between methods. STATISTICAL TESTS: Image quality features and perceived resolution were assessed with a mixed-effects logistic regression. Agreement among observers was estimated with a Krippendorf's alpha using linear weighting. Lesion feature ratings were visualized using histograms, and correlation coefficients of lesion ADC between different methods were calculated. RESULTS: MUSE and shot-LLR images were rated to have significantly better perceived resolution (P < 0.001), higher SNR (P < 0.005), and a lower level of distortion (P < 0.05) with respect to single-shot DWI. Shot-LLR showed reduced ghosting artifacts with respect to both MUSE (P < 0.001) and single-shot DWI (P < 0.001). Eight-shot DWI had improved perceived SNR and perceived resolution with respect to four-shot DWI (P < 0.005). DATA CONCLUSION: Multishot DWI enables increased resolution and improved image quality with respect to single-shot DWI in the breast. Shot-LLR reconstructs multishot DWI with minimal ghosting artifacts. The improvement of multishot DWI in image quality increases with an increased number of shots. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Imagen Eco-Planar , Artefactos , Femenino , Humanos , Imagen por Resonancia Magnética , Estudios Prospectivos , Reproducibilidad de los Resultados
17.
J Magn Reson Imaging ; 54(2): 357-371, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-32830874

RESUMEN

Artificial intelligence algorithms based on principles of deep learning (DL) have made a large impact on the acquisition, reconstruction, and interpretation of MRI data. Despite the large number of retrospective studies using DL, there are fewer applications of DL in the clinic on a routine basis. To address this large translational gap, we review the recent publications to determine three major use cases that DL can have in MRI, namely, that of model-free image synthesis, model-based image reconstruction, and image or pixel-level classification. For each of these three areas, we provide a framework for important considerations that consist of appropriate model training paradigms, evaluation of model robustness, downstream clinical utility, opportunities for future advances, as well recommendations for best current practices. We draw inspiration for this framework from advances in computer vision in natural imaging as well as additional healthcare fields. We further emphasize the need for reproducibility of research studies through the sharing of datasets and software. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY STAGE: 2.


Asunto(s)
Inteligencia Artificial , Aprendizaje Profundo , Algoritmos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Redes Neurales de la Computación , Estudios Prospectivos , Reproducibilidad de los Resultados , Estudios Retrospectivos
18.
J Magn Reson Imaging ; 53(5): 1594-1605, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33382171

RESUMEN

The image quality limitations of echo-planar diffusion-weighted imaging (DWI) are an obstacle to its widespread adoption in the breast. Steady-state DWI is an alternative DWI method with more robust image quality but its contrast for imaging breast cancer is not well-understood. The aim of this study was to develop and evaluate diffusion-weighted double-echo steady-state imaging with a three-dimensional cones trajectory (DW-DESS-Cones) as an alternative to conventional DWI for non-contrast-enhanced MRI in the breast. This prospective study included 28 women undergoing clinically indicated breast MRI and six asymptomatic volunteers. In vivo studies were performed at 3 T and included DW-DESS-Cones, DW-DESS-Cartesian, DWI, and CE-MRI acquisitions. Phantom experiments (diffusion phantom, High Precision Devices) and simulations were performed to establish framework for contrast of DW-DESS-Cones in comparison to DWI in the breast. Motion artifacts of DW-DESS-Cones were measured with artifact-to-noise ratio in volunteers and patients. Lesion-to-fibroglandular tissue signal ratios were measured, lesions were categorized as hyperintense or hypointense, and an image quality observer study was performed in DW-DESS-Cones and DWI in patients. Effect of DW-DESS-Cones method on motion artifacts was tested by mixed-effects generalized linear model. Effect of DW-DESS-Cones on signal in phantom was tested by quadratic regression. Correlation was calculated between DW-DESS-Cones and DWI lesion-to-fibroglandular tissue signal ratios. Inter-observer agreement was assessed with Gwet's AC. Simulations predicted hyperintensity of lesions with DW-DESS-Cones but at a 3% to 67% lower degree than with DWI. Motion artifacts were reduced with DW-DESS-Cones versus DW-DESS-Cartesian (p < 0.05). Lesion-to-fibroglandular tissue signal ratios were not correlated between DW-DESS-Cones and DWI (r = 0.25, p = 0.38). Concordant hyperintensity/hypointensity was observed between DW-DESS-Cones and DWI in 11/14 lesions. DW-DESS-Cones improved sharpness, distortion, and overall image quality versus DWI. DW-DESS-Cones may be able to eliminate motion artifacts in the breast allowing for investigation of higher degrees of steady-state diffusion weighting. Malignant breast lesions in DW-DESS-Cones demonstrated hyperintensity with respect to surrounding tissue without an injection of contrast. LEVEL OF EVIDENCE: 2. TECHNICAL EFFICACY STAGE: 1.


Asunto(s)
Neoplasias de la Mama , Imagen de Difusión por Resonancia Magnética , Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico por imagen , Imagen Eco-Planar , Femenino , Humanos , Imagen por Resonancia Magnética , Estudios Prospectivos
19.
Eur Radiol ; 31(12): 9369-9379, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33993332

RESUMEN

OBJECTIVES: To determine whether synovitis graded by radiologists using hybrid quantitative double-echo in steady-state (qDESS) images can be utilized as a non-contrast approach to assess synovitis in the knee, compared against the reference standard of contrast-enhanced MRI (CE-MRI). METHODS: Twenty-two knees (11 subjects) with moderate to severe osteoarthritis (OA) were scanned using CE-MRI, qDESS with a high diffusion weighting (qDESSHigh), and qDESS with a low diffusion weighting (qDESSLow). Four radiologists graded the overall impression of synovitis, their diagnostic confidence, and regional grading of synovitis severity at four sites (suprapatellar pouch, intercondylar notch, and medial and lateral peripatellar recesses) in the knee using a 4-point scale. Agreement between CE-MRI and qDESS, inter-rater agreement, and intra-rater agreement were assessed using a linearly weighted Gwet's AC2. RESULTS: Good agreement was seen between CE-MRI and both qDESSLow (AC2 = 0.74) and qDESSHigh (AC2 = 0.66) for the overall impression of synovitis, but both qDESS sequences tended to underestimate the severity of synovitis compared to CE-MRI. Good inter-rater agreement was seen for both qDESS sequences (AC2 = 0.74 for qDESSLow, AC2 = 0.64 for qDESSHigh), and good intra-rater agreement was seen for both sequences as well (qDESSLow AC2 = 0.78, qDESSHigh AC2 = 0.80). Diagnostic confidence was moderate to high for qDESSLow (mean = 2.36) and slightly less than moderate for qDESSHigh (mean = 1.86), compared to mostly high confidence for CE-MRI (mean = 2.73). CONCLUSIONS: qDESS shows potential as an alternative MRI technique for assessing the severity of synovitis without the use of a gadolinium-based contrast agent. KEY POINTS: The use of the quantitative double-echo in steady-state (qDESS) sequence for synovitis assessment does not require the use of a gadolinium-based contrast agent. Preliminary results found that low diffusion-weighted qDESS (qDESSLow) shows good agreement to contrast-enhanced MRI for characterization of the severity of synovitis, with a relative bias towards underestimation of severity. Preliminary results also found that qDESSLow shows good inter- and intra-rater agreement for the depiction of synovitis, particularly for readers experienced with the sequence.


Asunto(s)
Osteoartritis de la Rodilla , Sinovitis , Medios de Contraste , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Imagen por Resonancia Magnética , Osteoartritis de la Rodilla/diagnóstico por imagen , Membrana Sinovial , Sinovitis/diagnóstico por imagen
20.
AJR Am J Roentgenol ; 216(6): 1614-1625, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-32755384

RESUMEN

BACKGROUND. Potential approaches for abbreviated knee MRI, including prospective acceleration with deep learning, have achieved limited clinical implementation. OBJECTIVE. The objective of this study was to evaluate the interreader agreement between conventional knee MRI and a 5-minute 3D quantitative double-echo steady-state (qDESS) sequence with automatic T2 mapping and deep learning super-resolutionaugmentation and to compare the diagnostic performance of the two methods regarding findings from arthroscopic surgery. METHODS. Fifty-one patients with knee pain underwent knee MRI that included an additional 3D qDESS sequence with automatic T2 mapping. Fourier interpolation was followed by prospective deep learning super resolution to enhance qDESS slice resolution twofold. A musculoskeletal radiologist and a radiology resident performed independent retrospective evaluations of articular cartilage, menisci, ligaments, bones, extensor mechanism, and synovium using conventional MRI. Following a 2-month washout period, readers reviewed qDESS images alone followed by qDESS with the automatic T2 maps. Interreader agreement between conventional MRI and qDESS was computed using percentage agreement and Cohen kappa. The sensitivity and specificity of conventional MRI, qDESS alone, and qDESS plus T2 mapping were compared with arthroscopic findings using exact McNemar tests. RESULTS. Conventional MRI and qDESS showed 92% agreement in evaluating all tissues. Kappa was 0.79 (95% CI, 0.76-0.81) across all imaging findings. In 43 patients who underwent arthroscopy, sensitivity and specificity were not significantly different (p = .23 to > .99) between conventional MRI (sensitivity, 58-93%; specificity, 27-87%) and qDESS alone (sensitivity, 54-90%; specificity, 23-91%) for cartilage, menisci, ligaments, and synovium. For grade 1 cartilage lesions, sensitivity and specificity were 33% and 56%, respectively, for conventional MRI; 23% and 53% for qDESS (p = .81); and 46% and 39% for qDESS with T2 mapping (p = .80). For grade 2A lesions, values were 27% and 53% for conventional MRI, 26% and 52% for qDESS (p = .02), and 58% and 40% for qDESS with T2 mapping (p < .001). CONCLUSION. The qDESS method prospectively augmented with deep learning showed strong interreader agreement with conventional knee MRI and near-equivalent diagnostic performance regarding arthroscopy. The ability of qDESS to automatically generate T2 maps increases sensitivity for cartilage abnormalities. CLINICAL IMPACT. Using prospective artificial intelligence to enhance qDESS image quality may facilitate an abbreviated knee MRI protocol while generating quantitative T2 maps.


Asunto(s)
Medios de Contraste , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Traumatismos de la Rodilla/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Inteligencia Artificial , Estudios de Evaluación como Asunto , Femenino , Humanos , Imagenología Tridimensional/métodos , Articulación de la Rodilla/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tiempo , Adulto Joven