Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.297
Filtrar
Más filtros

Intervalo de año de publicación
1.
Audiol Neurootol ; : 1-8, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38697033

RESUMEN

INTRODUCTION: The aim of this study was to examine how bimodal stimulation affects quality of life (QOL) during the postoperative period following cochlear implantation (CI). These data could potentially provide evidence to encourage more bimodal candidates to continue hearing aid (HA) use after CI. METHODS: In this prospective study, patients completed preoperative and 1-, 3-, and 6-month post-activation QOL surveys on listening effort, speech perception, sound quality/localization, and hearing handicap. Fifteen HA users who were candidates for contralateral CI completed the study (mean age 65.6 years). RESULTS: Patients used both devices at a median rate of 97%, 97%, and 98% of the time at 1, 3, and 6 months, respectively. On average, patients' hearing handicap scores decreased by 16% at 1 month, 36% at 3 months, and 30% at 6 months. Patients' listening effort scores decreased by a mean of 10.8% at 1 month, 12.6% at 3 months, and 18.7% at 6 months. Localization significantly improved by 24.3% at 1 month and remained steady. There was no significant improvement in sound quality scores. CONCLUSION: Bimodal listeners should expect QOL to improve, and listening effort and localization are generally optimized using CI and HA compared to CI alone. Some scores improved at earlier time points than others, suggesting bimodal auditory skills may develop at different rates.

2.
Audiol Neurootol ; 29(3): 207-215, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38211575

RESUMEN

INTRODUCTION: Preoperative evaluation of cochlear morphology is important for successful cochlear implantation. This study analyzed the cochlear canal by three-dimensional reconstructions of temporal bones using computed tomography (CT). METHODS: Fifty temporal bones from 25 patients aged 42-74 years were evaluated. The inner spaces of the bony cochlea were reconstructed using a surface rendering technique on the CT images. Eight angular points (P0-P7) every 90° were selected from 0° to 630° from the center of the round window using the reconstructed cochlear canal images. The radius (R) and thickness (T) of the cochlear canal at each point were measured. The cochlear canal length (CoCL) was estimated using an equation based on the radius at each point. The cochlear width and height based on multiplanar CT images were also measured and compared with the length and volume of the cochlear canal. RESULTS: The mean CoCL from 0° to 630° was 31.5 mm, and the cochlear volume was 55.9 mm3. The CoCL to P7 was correlated with the cochlear volume (r = 0.77), coiling ratios (R4/R0, r = 0.47; R5/R1, r = 0.384), cochlear width (long) (r = 0.539), cochlear height (r = 0.385), and total thickness at each point (r = 0.475). The cochlear volume was correlated with CoCL (630°) (r = 0.77), coiling ratio (R4/R0, r = 0.367), cochlear width (long) (r = 0.616), cochlear height (r = 0.447), and total T (r = 0.566). CONCLUSION: Preoperative evaluation using three-dimensional reconstruction can elucidate the size and shape of the cochlear canal before cochlear implantation.


Asunto(s)
Cóclea , Implantación Coclear , Imagenología Tridimensional , Tomografía Computarizada por Rayos X , Humanos , Implantación Coclear/métodos , Anciano , Cóclea/diagnóstico por imagen , Cóclea/cirugía , Adulto , Persona de Mediana Edad , Masculino , Femenino , Hueso Temporal/diagnóstico por imagen , Hueso Temporal/anatomía & histología , Hueso Temporal/cirugía
3.
Cereb Cortex ; 33(5): 2229-2244, 2023 02 20.
Artículo en Inglés | MEDLINE | ID: mdl-35640270

RESUMEN

In asymmetric hearing loss (AHL), the normal pattern of contralateral hemispheric dominance for monaural stimulation is modified, with a shift towards the hemisphere ipsilateral to the better ear. The extent of this shift has been shown to relate to sound localization deficits. In this study, we examined whether cochlear implantation to treat postlingual AHL can restore the normal functional pattern of auditory cortical activity and whether this relates to improved sound localization. The auditory cortical activity was found to be lower in the AHL cochlear implanted (AHL-CI) participants. A cortical asymmetry index was calculated and showed that a normal contralateral dominance was restored in the AHL-CI patients for the nonimplanted ear, but not for the ear with the cochlear implant. It was found that the contralateral dominance for the nonimplanted ear strongly correlated with sound localization performance (rho = 0.8, P < 0.05). We conclude that the reorganization of binaural mechanisms in AHL-CI subjects reverses the abnormal lateralization pattern induced by the deafness, and that this leads to improved spatial hearing. Our results suggest that cochlear implantation enables the reconstruction of the cortical mechanisms of spatial selectivity needed for sound localization.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Pérdida Auditiva , Localización de Sonidos , Percepción del Habla , Humanos , Implantación Coclear/métodos , Audición/fisiología , Localización de Sonidos/fisiología , Tomografía de Emisión de Positrones , Percepción del Habla/fisiología
4.
Am J Otolaryngol ; 45(1): 104050, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37741025

RESUMEN

BACKGROUND: Cochlear implantation (CI) in children with malformed ears can be challenging through the standard surgical technique. Several alternative approaches have been described. The endoscopic-assisted approach can be chosen as an effective and safe surgical technique, overcoming the drawbacks of the traditional approach. MATERIAL: We further describe a combined technique based on a limited mastoidectomy with no posterior tympanotomy and an endoscopic transmeatal approach to the round window (RW): the electrode is driven from the mastoid to the middle ear through the attic. RESULTS: The concomitant endoscopic assistance allows for improved surgical vision, reducing the risk of major complications. The main advantages of this technique are related to better visualization of the RW for safe insertion of the electrode; avoidance of damage to the facial nerve (FN), due to direct visualization, and sparing the posterior tympanotomy; avoidance of subtotal petrosectomy, if not necessary. CONCLUSION: The purpose of this article, supported with a video file, is to describe step by step this endoscopic-assisted procedure in a patient with middle ear malformation.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Niño , Humanos , Implantación Coclear/métodos , Oído/cirugía , Oído Medio/cirugía , Audición , Ventana Redonda/cirugía
5.
Am J Otolaryngol ; 45(1): 104071, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37793300

RESUMEN

OBJECTIVE: The purpose of this study is to investigate how cognition, as measured using the Self-Administered Gerocognitive Examination Test (SAGE), and age affect speech recognition scores in older adults (age > 65) at one year and two years after cochlear implantation. STUDY DESIGN: This is a prospective study. SETTING: This study was conducted at a single institution. METHODS: Unilateral cochlear implantation was performed by two surgeons on adult patients (>65 years) with postlingual bilateral sensorineural hearing loss. There were 230 patients who underwent cochlear implantation from January 2016 to June 2023. Fifty-five of these patients completed the SAGE questionnaire before implantation, one year after implantation, and 2 years after implantation. Paired t-test analysis was used to evaluate pre- and post-operative speech recognition scores (CNC, AzBio in Quiet). RESULTS: Patients who had normal preoperative cognition on SAGE showed greater improvement in postoperative speech recognition tests at 1 year and 2 years after implantation compared with patients who showed preoperative cognitive impairment. There were no significant differences in postoperative speech outcome between age group 1 (between 65 and 80 years old) and age group 2 (over 80 years old) cochlear implant recipients. There were no changes in cognitive SAGE scores after 2 years implantation. CONCLUSION: Cognitive function, as measured by SAGE, is a more reliable predictor than age in determining speech recognition improvement after cochlear implantation. Cochlear implantation did not improve postoperative cognition.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Humanos , Anciano , Lactante , Estudios Prospectivos , Habla , Resultado del Tratamiento , Cognición
6.
Am J Otolaryngol ; 45(4): 104337, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38677145

RESUMEN

OBJECTIVE: To describe an AI model to facilitate adult cochlear implant candidacy prediction based on basic demographical data and standard behavioral audiometry. METHODS: A machine-learning approach using retrospective demographic and audiometric data to predict candidacy CNC word scores and AzBio sentence in quiet scores was performed at a tertiary academic center. Data for the model were derived from adults completing cochlear implant candidacy testing between January 2011 and March 2023. Comparison of the prediction model to other published prediction tools and benchmarks was performed. RESULTS: The final dataset included 770 adults, encompassing 1045 AzBio entries, and 1373 CNC entries. Isophoneme scores and word recognition scores exhibited strongest importance to both the CNC and AzBio prediction models, followed by standard pure tone average and low-frequency pure tone average. The mean absolute difference between the predicted and actual score was 15 percentage points for AzBio sentences in quiet and 13 percentage points for CNC word scores, approximating anticipated test-retest constraints inherent to the variables incorporated into the model. Our final combined model achieved an accuracy of 87 % (sensitivity: 90 %; precision: 80 %). CONCLUSION: We present an adaptive AI model that predicts adult cochlear implant candidacy based on routine behavioral audiometric and basic demographical data. Implementation efforts include a public-facing online prediction tool and accompanying smartphone program, an embedded notification flag in the electronic medical record to alert providers of potential candidates, and a program to retrospectively engage past patients who may be eligible for cochlear implantation based on audiogram results.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Humanos , Masculino , Persona de Mediana Edad , Femenino , Adulto , Estudios Retrospectivos , Implantación Coclear/métodos , Anciano , Audiometría/métodos , Aprendizaje Automático , Selección de Paciente , Adulto Joven , Anciano de 80 o más Años
7.
Am J Otolaryngol ; 45(2): 104138, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38101137

RESUMEN

PURPOSE: To investigate the benefits of cochlear implantation in adults with single-sided deafness (SSD) and asymmetric hearing loss (AHL). STUDY DESIGN: Prospective within-subjects repeated-measures. SETTING: Two tertiary cochlear implant centers. PATIENTS: Fourteen adults with severe-to-profound sensorineural hearing loss in the worse hearing ear and up to moderate SNHL in the better hearing ear. INTERVENTION: Cochlear implantation in the worse hearing ear. MAIN OUTCOME MEASURES: Consonant-nucleus-consonant (CNC) test, AzBio sentence test in noise, and lateralization testing were conducted preoperatively and at 3-, 6-, and 12-months post-activation. Patient-related outcomes were measured using the Speech, Spatial, and Qualities of Hearing Scale and Glasgow Benefit Inventory. Tinnitus Handicap Inventory was administered to subjects with tinnitus. RESULTS: Mean length of hearing loss in the worse hearing ear was 3.5 years. The mean CNC change scores from baseline were 54.8, 55.9, and 58.9 percentage points at 3-, 6-, and 12-months (p < 0.001). AzBio sentence test in noise demonstrated improved scores in all spatial configurations, although statistically significant in S0N0 (speech front, noise front) only. Lateralization testing showed significant improvement of 22.9, 24.5, and 24.0 percentage points at 3-, 6-, and 12 months post-activation (p = 0.002). All patient-related outcome measures revealed significant improvement. CONCLUSION: This study demonstrates improved speech perception in noise, sound lateralization, quality of life, and reduction in tinnitus perception in adults with SSD/AHL who undergo cochlear implantation. Our results add to the growing body of evidence that cochlear implant should be offered to this population.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Pérdida Auditiva Unilateral , Pérdida Auditiva , Percepción del Habla , Acúfeno , Adulto , Humanos , Implantación Coclear/métodos , Acúfeno/cirugía , Calidad de Vida , Estudios Prospectivos , Resultado del Tratamiento , Pérdida Auditiva/cirugía , Percepción del Habla/fisiología , Pérdida Auditiva Unilateral/cirugía , Pérdida Auditiva Unilateral/rehabilitación
8.
Am J Otolaryngol ; 45(5): 104360, 2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38754261

RESUMEN

INTRODUCTION: Robot-assisted cochlear implant surgery (RACIS) as defined by the HEARO®-procedure performs minimal invasive cochlear implant (CI) surgery by directly drilling a keyhole trajectory towards the inner ear. Hitherto, an entirely robotic automation including electrode insertion has not been described yet. The feasability of using a newly developed, dedicated motorised device for automated electrode insertion in the first clinical case of entirely robotic cochlear implant surgery was investigated. AIM: The aim is to report the first experience of entirely robotic cochlear implantation surgery. INTERVENTION: RACIS with a straight flexible lateral wall electrode. PRIMARY OUTCOME MEASUREMENTS: Electrode cochlear insertion depth. SECONDARY OUTCOME MEASUREMENTS: The audiological outcome in terms of mean hearing thresholds. CONCLUSION: Here, we report on a cochlear implant robot that performs the most complex surgical steps to place a cochlear implant array successfully in the inner ear and render similar audiological results as in conventional surgery. Robots can execute tasks beyond human dexterity and will probably pave the way to standardize residual hearing preservation and broadening the indication for electric-acoustic stimulation in the same ear with hybrid implants.

9.
Eur Arch Otorhinolaryngol ; 281(3): 1597-1602, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38070047

RESUMEN

PURPOSE: We investigate the clinical manifestations, mechanisms, and methods of preventing electrode migration in Cochlear Implantation (CI) patients, based on our practical experience with this problem. STUDY DESIGN: This is a retrospective study in a single center. METHODS: We retrospectively reviewed electrode migration in 4 (0.75%) of 532 patients who underwent CI at our tertiary institution from January 2002 to December 2022. Pre- and post-operative pure-tone audiometry, word recognition score, aided functional gain test, and sound field speech intelligibility test were evaluated. RESULTS: All four patients underwent CIs with the straight electrode type. The following events or symptoms were observed in the patients before confirming electrode migration: an increase in high-frequency thresholds during the post-operative aided functional gain test and a decline in scores on the sound field speech intelligibility test. Electrode migration was confirmed through transocular view X-ray or temporal bone computer tomography. Two patients showed coiled electrodes within the mastoid cavity; while in the others, the electrodes were observed to be floating inside the cavity. To prevent migration of electrodes due to these issues, we mixed bone paste collected during the drilling of the mastoid cavity with glue and used it to secure the electrodes in place. CONCLUSION: Electrode migration can result in a decrease in hearing ability and may necessitate a revision surgery to adjust the electrode placement. The main factors affecting electrode placement include the position of electrode within the mastoid cavity and the elasticity of straight electrodes. It is important for surgeons to recognize the factors that increase the risk of electrode migration and to take preventative measures to reduce this risk.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Humanos , Implantes Cocleares/efectos adversos , Implantación Coclear/efectos adversos , Implantación Coclear/métodos , Estudios Retrospectivos , Audición , Audiometría de Tonos Puros
10.
Artículo en Inglés | MEDLINE | ID: mdl-38914818

RESUMEN

INTRODUCTION: In this study we investigated the effect of cochlear implantation on tinnitus in patients with post lingual bilateral profound hearing loss. METHODS: In this retrospective study, 66 post-lingual deaf patients over 18 years old who referred for cochlear implantation and complained of tinnitus were included. Patients were divided into two groups with residual hearing (in frequency 250-500 Hz) and without residual hearing. All data including age, gender, type of implants, type of surgery, cause of the disease, and information on the THI score before cochlear implantation, one month after cochlear implantation and one year after cochlear implantation was recorded and analyzed. RESULTS: Nine patients had residual hearing, while 57 patients did not. After one month and one year, in both groups, the mean THI score has decreased significantly (p-value = 0.001), but there was no significant difference in the mean THI score before surgery and one month and one year after surgery between two groups with and without residual hearing. There was no significant difference in tinnitus severity according to THI-grade between two groups. Also there was no significant difference in THI score and the cause of the hearing loss, type and insertion method of implantation, one month and one year after the surgery between two groups. CONCLUSION: According to our results, the was no significant correlation between residual hearing and tinnitus score before surgery, one month and one year after the surgery.

11.
Eur Arch Otorhinolaryngol ; 281(3): 1175-1183, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37646794

RESUMEN

INTRODUCTION: Real-time visualization of intraoperative electrocochleography (ECochG) potentials via a digital microscope during cochlear implantation can provide direct feedback during electrode insertion. The aim of this prospective, randomized study of 50 patients was to obtain long-term data with a focus on residual hearing preservation and speech understanding. MATERIAL AND METHODS: Cochlear implantations were performed in 50 patients (26 female, 24 male) with residual hearing using a digital microscope. Patients were randomized into two groups. Intraoperative ECochG potentials were either displayed directly in the surgeon's field of view (picture-in-picture display, PiP) or not directly in the field of view (without picture-in-picture display, without PiP). Residual hearing preservation and speech comprehension were recorded within a 1-year follow-up period, compared between groups (PiP versus without PiP) and to a control group of 26 patients implanted without ECochG. RESULTS: Mean insertion time was significantly longer in the picture-in-picture group (p = 0.025). Residual hearing preservation after 6 weeks at 250 Hz was significantly better in the picture-in-picture group (p = 0.017). After one year, 76% of patients showed residual hearing in the picture-in-picture group (62% without picture-in-picture technique, p = n.s.). Use of the picture-in-picture technique resulted in better long-term pure tone residual hearing preservation at 250, 500, and 1000 Hz. Speech intelligibility improved by 46% in the picture-in-picture group (38% without picture-in-picture). DISCUSSION: This study is the first to describe long-term results in a large cohort of cochlear implant patients in whom digital visualization of intraoperative ECochG was used. Our results show that visualization of intraoperative ECochG has a positive effect on residual hearing preservation.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Humanos , Masculino , Femenino , Implantación Coclear/métodos , Cóclea/cirugía , Audiometría de Respuesta Evocada/métodos , Inteligibilidad del Habla
12.
Eur Arch Otorhinolaryngol ; 281(2): 719-729, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37548704

RESUMEN

PURPOSE: The aim of this study was to compare the outcomes of different mapping procedures based on anatomic or default frequency distribution in postlingual deafness adults who underwent cochlear implantation (CI). METHODS: Forty-eight adults with postlingual deafness who underwent CI (MED-EL) from January 2021 to May 2022 in our hospital were prospectively recruited. The participants were randomly assigned to two groups (the anatomic group and the default group). Postoperative computerized tomography (CT) scans were evaluated with Otoplan® to determine the angular insertion depth (AID) and the specific locations of the intracochlear electrodes. Anatomic maps were imported into MAESTRO 9.0 software (MED-EL) for anatomy-based fitting for anatomic group, while default mapping program was set up for the default group. Hearing thresholds, Speech Recognition Scores (SRS), and subjects' auditory and musical abilities were evaluated 1 year after using the CI. Differences were determined in two groups using Stata statistical software, with significance defined as p < 0.05. RESULTS: SRS under noisy conditions was significantly greater for anatomic group than the default group (p = 0.02). Under quiet conditions, however, mean hearing thresholds (0.5, 1, 2, and 4 kHz) and SRS did not differ significantly between the two groups (p = 0.07). Modified questionnaires showed that auditory (p = 0.02) and musical (p = 0.01) quality were significantly better following the anatomic mapping than the default procedure. CONCLUSION: CI program based on the anatomic distribution may bring better SRS under noise conditions as well as better auditory and musical qualities than based on the default frequency distribution.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Percepción del Habla , Adulto , Humanos , Implantación Coclear/métodos , Sordera/cirugía , Resultado del Tratamiento , Audición
13.
Artículo en Inglés | MEDLINE | ID: mdl-38977476

RESUMEN

OBJECTIVE: The aim of this study was to conduct a bibliometric and visualization analysis of research on cochlear implantation (CI) for inner ear malformations (IEMs) from 1986 to 2024. METHODS: A comprehensive literature search was performed using the Web of Science Core Collection Database, resulting in the identification of 431 relevant publications. Various data analysis and visualization tools, including VOSviewer, CiteSpace, and Bibliometrix, were utilized to analyze annual publication outputs, countries/regions and institutions, authors, journals and studies, keywords, and theme evolution. RESULTS: The study revealed an overall increasing trend in research output on CI for IEMs, with significant contributions from countries such as the United States, China, Turkey, Germany, and Italy. The analysis also identified key authors, research teams, journals, and studies that have made substantial contributions to the field. Furthermore, the study highlighted important research hotspots and trends, such as the classification of IEMs, outcomes of CI for IEMs, and the management of pediatric patients with IEMs. CONCLUSION: The findings of this study provide a comprehensive overview of the research landscape surrounding CI for IEMs. The results serve as a basis for future research topic selection and emphasize the need for enhanced international collaboration and the publication of high-impact research to further advance this field.

14.
Artículo en Inglés | MEDLINE | ID: mdl-38802577

RESUMEN

PURPOSE: This study aimed to investigate the etiology of hearing loss, including genetic variants, in individuals who underwent cochlear implantation (CI) in their teens to thirties. It also sought to analyze post-CI speech performance and identify prognostic factors affecting CI outcomes in this age group. METHODS: We conducted a retrospective review of 421 cochlear implant patients at Seoul National University Bundang Hospital, focusing on 63 subjects aged 10-39 years who underwent their first CI by a single surgeon between July 2018 and June 2022. The study included audiologic evaluation, molecular genetic testing, and analysis of speech performance post-CI. Statistical analyses were performed using SPSS 25 and GraphPad Prism 7. RESULTS: Among 63 participants (M:F, 24:39), nine underwent CI in their teens, 24 in their 20 s, and 30 in their 30 s. Most of them (40, 63.5%) had postlingual deafness. The study found that 65.2% (40/63) of subjects received a genetic diagnosis, with DFNB4 being the most common etiology (37.5%, 15/40). Post-CI speech evaluation showed an average sentence score of 80% across all subjects. Factors such as the onset of hearing loss, duration of deafness (DoD), and preoperative Speech Intelligibility Rating (SIR) significantly influenced CI outcomes. Notably, longer DoD was associated with poorer CI outcomes, but this did not affect individuals with postlingual hearing loss as much. CONCLUSION: The study concludes that in individuals aged 10-39 undergoing CI, the onset of hearing loss and preoperative SIR are critical predictors of postoperative outcomes. CI is recommended for those with postlingual hearing loss in this age group, irrespective of the DoD. The study highlights the importance of genetic factors especially DFNB4 in hearing loss etiology and underscores the value of the relatively easy-to-evaluate factor, preoperative SIR in predicting CI outcomes.

15.
Artículo en Inglés | MEDLINE | ID: mdl-38758241

RESUMEN

OBJECTIVES: This study aimed to explore the diagnostic sensitivity of 3D heavily weighted T2-weighted MRI (T2MRI) and high-resolution computed tomography (HRCT) in patients with cochlear fibrosis associated with Streptococcus suis (S. suis) meningitis and the practicality of Cochlear implantation (CI) treatments. METHODS: Between January 2020 and December 2022, we enrolled four patients with rare cochlear S. suis meningitis with associated hearing loss despite aggressive or non-aggressive follow-up antibiotic treatment. Clinical imaging data, surgical performances and post-surgical-electrode impedance were evaluated. RESULTS: Combined with HRCT and T2MRI, the cochlea had varying degrees of fibrosis and ossification in different cases. However, the electrodes were successfully and wholly inserted after intraoperative removal of the ossified and fibrotic foci. Post-surgical electrode impedance values of MP1 + 2 mode were normal in all 4 cases at initial activation. CONCLUSION: In patients with S. suis meningitis and associated cochlear fibrosis, T2MRI examination of the inner ear was more sensitive than HRCT. This research highlights the feasibility of CI treatment in S. suis meningitis patients with severe cochlear fibrosis.

16.
Eur Arch Otorhinolaryngol ; 281(6): 2913-2920, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38170210

RESUMEN

PURPOSE: The study explores the potential of real-time electrocochleographic potentials (ECochG) visualization during electrode insertion using digital microscopes such as RoboticScope (BHS®). Collaborative software development of the MAESTRO Software (MED-EL®) offers continuous ECochG monitoring during implantation and postoperative hearing evaluation, addressing previous time constraints. The study aims to assess software applicability and the impact of real-time visualization on long-term residual hearing preservation. METHODS: Eight patients with residual hearing underwent cochlear implantation with Flex26 or Flex28 electrode according to the Otoplan evaluation. ECochG responses were measured and visualized during electrode insertion, with insertion times recorded. Two randomized display methods (graph and arrows) tracked ECochG potentials. Postoperative behavioral thresholds determined hearing preservation. Successful real-time intraoperative ECochG visualization was achieved in all cases, enabling surgeon adaptation. Mean electrode insertion time was 114 s, with postoperative thresholds comparable to preoperative values. Visualization did not affect surgeon workload. ECochG amplitudes differed between patients with and without residual hearing. CONCLUSION: The study demonstrates effective implementation of advanced ECochG software combined with real-time visualization, enabling residual hearing preservation during CI. Visualization had no apparent effect on surgeon performance or workload. Future investigation involving a larger population will assess the long-term impact of ECochG on hearing threshold and structure preservation.


Asunto(s)
Audiometría de Respuesta Evocada , Implantación Coclear , Estudios de Factibilidad , Programas Informáticos , Humanos , Implantación Coclear/métodos , Audiometría de Respuesta Evocada/métodos , Femenino , Masculino , Persona de Mediana Edad , Adulto , Anciano , Implantes Cocleares
17.
Eur Arch Otorhinolaryngol ; 281(3): 1603-1608, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38150022

RESUMEN

OBJECTIVE: Report three cases of simultaneous triple semicircular canal occlusion (TSCO) and cochlear implantation (CI) as the treatment of intractable Meniere's disease (MD). CASE REPORTS: Patients with MD can present occasionally with intractable vertigo and profound sensorineural hearing loss (SNHL). TSCO and CI have been proposed to control vertigo and restore profound deafness in patients with MD separately. However, a few studies have reported simultaneous TSCO and CI in the same surgical procedure for the treatment of MD. In the present study, we described three patients with MD showing incapacitating vertigo and severe SNHL who underwent simultaneous TSCO and CI after examinations of auditory system, vestibular system, and imaging. Their symptoms were significantly alleviated during the follow-up period. CONCLUSION: The combined TSCO and CI remains a viable treatment option which is effective for the control of vertigo as well as the restoring of hearing in patients with MD.


Asunto(s)
Implantación Coclear , Pérdida Auditiva Sensorineural , Enfermedad de Meniere , Humanos , Enfermedad de Meniere/complicaciones , Enfermedad de Meniere/cirugía , Vértigo/etiología , Vértigo/cirugía , Canales Semicirculares/cirugía , Audición , Pérdida Auditiva Sensorineural/etiología , Pérdida Auditiva Sensorineural/cirugía
18.
Eur Arch Otorhinolaryngol ; 281(7): 3483-3490, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38302621

RESUMEN

AIM: Intratympanic injection of corticosteroids (ITC) and gentamicin therapy (ITG) are widely used treatments for vertigo in Meniere's disease (MD). Even though studies show good results after cochlea implantation (CI) in MD patients when compared to non-MD groups, there is no indication on the effect of ITC and ITG prior to CI on hearing after CI. This study compares the post-operative hearing of CI patients with and without MD and patients who have received ITG or ITC prior to CI. METHODS: In a retrospective case control study, adult patients with MD who received CI from 2002 till 2021 were compared to a matched control group of CI patients without MD. Patients with prior ITC/ITG were extracted from MD group. Pre-operative audiological results were measured and trends across post-operative monosyllabic word recognition score at 65 decibels (WRS65CI) at switch-on, 3-6 months, 1 year and last yearly value were analyzed across all groups. RESULTS: 28 MD ears were compared with 33 control ears. From MD ears 9 had received ITG and 6 ITC prior to CI. WRS65CI increased significantly with time within MD and control groups, but no difference in WRS65CI was found between these 2 groups. ITG ears showed fluctuating WRS65CI after CI with no change across time, while ITC ears showed significant increase in trend of WRS65CI values across time. CONCLUSION: MD and non-MD patients showed comparable hearing results after CI. Prior ITC might positively influence hearing preservation after CI in MD patients whereas ITG group showed fluctuating hearing.


Asunto(s)
Implantación Coclear , Gentamicinas , Inyección Intratimpánica , Enfermedad de Meniere , Percepción del Habla , Humanos , Enfermedad de Meniere/tratamiento farmacológico , Gentamicinas/administración & dosificación , Gentamicinas/uso terapéutico , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Estudios de Casos y Controles , Adulto , Anciano , Glucocorticoides/administración & dosificación , Glucocorticoides/uso terapéutico , Antibacterianos/administración & dosificación , Antibacterianos/uso terapéutico , Corticoesteroides/administración & dosificación , Corticoesteroides/uso terapéutico , Resultado del Tratamiento
19.
Artículo en Inglés | MEDLINE | ID: mdl-38767697

RESUMEN

PURPOSE: Patients suffering from Ménière's disease (MD) experience vertigo, and impairments in hearing and quality of life (QoL). This study aims to investigate the impact of cochlear implantation (CI) on various aspects affecting patients with MD. METHODS: A single tertiary centre's CI database for CI recipients with MD between 2014 and 2022 was screened retrospectively. Hearing, vertigo, tinnitus symptoms, and hearing-related QoL were assessed. Pre- and postoperative hearing tests in conjunction with subjective outcome measures by visual analogue scale (VAS) and validated tools such as the Dizziness Handicap Inventory (DHI), Tinnitus Handicap Inventory (THI) and Nijmegen Cochlear Implant Questionnaire (NCIQ), as well as the assessment of the pre- and postoperative Functional Level Scale (FLS) were examined. RESULTS: Eleven ears were included (median age: 59 years at implantation). Following implantation, there was a significant enhancement in Word Recognition Scores at sound levels of 65 dB and 80 dB compared to before treatment (preop vs. 12 months postop: p = 0.012). However, no significant enhancement was observed for 50 dB. MD-related impairments improved significantly postoperatively, as measured by the VAS (vertigo: p = 0.017; tinnitus: p = 0.042), DHI (p = 0.043), THI (p = 0.043) and NCIQ (p < 0.001). The FLS improved significantly (p = 0.020). CONCLUSION: CI has positive effects on all areas examined in our cohort. However, discrimination of speech at low sound pressure levels remained problematic postoperatively. In patients suffering from MD, the prioritized treatment goals include not only improved hearing but also the rehabilitation of vertigo and tinnitus, as well as the enhancement of QoL. Validated instruments are useful screening tools.

20.
Eur Arch Otorhinolaryngol ; 281(7): 3535-3545, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38353769

RESUMEN

OBJECTIVE: The objectives of this study are twofold: first, to visualize the structure of malformed cochleae through image reconstruction; and second, to develop a predictive model for postoperative outcomes of cochlear implantation (CI) in patients diagnosed with cochlear hypoplasia (CH) and incomplete partition (IP) malformation. METHODS: The clinical data from patients diagnosed with cochlear hypoplasia (CH) and incomplete partition (IP) malformation who underwent cochlear implantation (CI) at Beijing Tongren Hospital between January 2016 and August 2020 were collected. Radiological features were analyzed through 3D segmentation of the cochlea. Postoperative auditory speech rehabilitation outcomes were evaluated using the Categories of Auditory Performance (CAP) and the Speech Intelligibility Rating (SIR). This study aimed to investigate the relationship between cochlear parameters and postoperative outcomes. Additionally, a predictive model for postoperative outcomes was developed using the K-nearest neighbors (KNN) algorithm. RESULTS: In our study, we conducted feature selection by using patients' imaging and audiological attributes. This process involved methods such as the removal of missing values, correlation analysis, and chi-square tests. The findings indicated that two specific features, cochlear volume (V) and cochlear canal length (CDL), significantly contributed to predicting the outcomes of hearing and speech rehabilitation for patients with inner ear malformations. In terms of hearing rehabilitation, the KNN classification achieved an accuracy of 93.3%. Likewise, for speech rehabilitation, the KNN classification demonstrated an accuracy of 86.7%. CONCLUSION: The measurements obtained from the 3D reconstruction model hold significant clinical relevance. Despite the considerable variability in cochlear morphology across individuals, radiological features remain effective in predicting cochlear implantation (CI) prognosis for patients with inner ear malformations. The utilization of 3D segmentation techniques and the developed predictive model can assist surgeons in conducting preoperative cochlear structural measurements for patients with inner ear malformations. This, in turn, can offer a more informed perspective on the anticipated outcomes of cochlear implantation.


Asunto(s)
Cóclea , Implantación Coclear , Aprendizaje Automático , Humanos , Implantación Coclear/métodos , Masculino , Femenino , Cóclea/anomalías , Cóclea/diagnóstico por imagen , Cóclea/cirugía , Lactante , Resultado del Tratamiento , Preescolar , Oído Interno/anomalías , Oído Interno/cirugía , Oído Interno/diagnóstico por imagen , Imagenología Tridimensional , Estudios Retrospectivos , Niño
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA