1.
Magn Reson Med ; 87(5): 2372-2379, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34894639

RESUMEN

PURPOSE: This study aimed at developing a 3D reduced field-of-view imaging (3D-rFOVI) technique using a 2D radiofrequency (RF) pulse, and demonstrating its ability to achieve isotropic high spatial resolution and reduced image distortion in echo planar imaging (EPI). METHODS: The proposed 3D-rFOVI technique takes advantage of a 2D RF pulse to excite a slab along the conventional slice-selection direction (i.e., z-direction) while limiting the spatial extent along the phase-encoded direction (i.e., y-direction) within the slab. The slab is phase-encoded in both through-slab and in-slab phase-encoded directions. The 3D-rFOVI technique was implemented at 3T in gradient-echo and spin-echo EPI pulse sequences for functional MRI (fMRI) and diffusion-weighted imaging (DWI), respectively. 3D-rFOVI experiments were performed on a phantom and human brain to illustrate image distortion reduction, as well as isotropic high spatial resolution, in comparison with 3D full-FOV imaging. RESULTS: In both the phantom and the human brain, image voxel dislocation was substantially reduced by 3D-rFOVI when compared with full-FOV imaging. In the fMRI experiment with visual stimulation, 3D isotropic spatial resolution of (2 × 2 × 2 mm3 ) was achieved with an adequate signal-to-noise ratio (81.5) and blood oxygen level-dependent (BOLD) contrast (2.5%). In the DWI experiment, diffusion-weighted brain images with an isotropic resolution of (1 × 1 × 1 mm3 ) was obtained without appreciable image distortion. CONCLUSION: This study indicates that 3D-rFOVI is a viable approach to 3D neuroimaging over a zoomed region.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Imagen Eco-Planar , Imagen de Difusión por Resonancia Magnética/métodos , Imagen Eco-Planar/métodos , Humanos , Imagenología Tridimensional/métodos , Fantasmas de Imagen , Relación Señal-Ruido
2.
Magn Reson Med ; 86(2): 791-803, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33748985

RESUMEN

PURPOSE: We combine SNR-efficient acquisition and model-based reconstruction strategies with newly available hardware instrumentation to achieve distortion-free in vivo diffusion MRI of the brain at submillimeter-isotropic resolution with high fidelity and sensitivity on a clinical 3T scanner. METHODS: We propose blip-up/down acquisition (BUDA) for multishot EPI using interleaved blip-up/blip-down phase encoding and incorporate B0 forward-modeling into structured low-rank reconstruction to enable distortion-free and navigator-free diffusion MRI. We further combine BUDA-EPI with an SNR-efficient simultaneous multislab acquisition (generalized slice-dithered enhanced resolution ["gSlider"]), to achieve high-isotropic-resolution diffusion MRI. To validate gSlider BUDA-EPI, whole-brain diffusion data at 860-µm and 780-µm data sets were acquired. Finally, to improve the conditioning and minimize noise penalty in BUDA reconstruction at very high resolutions where B0 inhomogeneity can have a detrimental effect, the level of B0 inhomogeneity was reduced by incorporating slab-by-slab dynamic shimming with a 32-channel AC/DC coil into the acquisition. Whole-brain 600-µm diffusion data were then acquired with this combined approach of gSlider BUDA-EPI with dynamic shimming. RESULTS: The results of 860-µm and 780-µm datasets show high geometry fidelity with gSlider BUDA-EPI. With dynamic shimming, the BUDA reconstruction's noise penalty was further alleviated. This enables whole-brain 600-µm isotropic resolution diffusion imaging with high image quality. CONCLUSIONS: The gSlider BUDA-EPI method enables high-quality, distortion-free diffusion imaging across the whole brain at submillimeter resolution, where the use of multicoil dynamic B0 shimming further improves reconstruction performance, which can be particularly useful at very high resolutions.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Procesamiento de Imagen Asistido por Computador , Encéfalo/diagnóstico por imagen , Imagen Eco-Planar
3.
Magn Reson Med ; 83(3): 988-1002, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31535729

RESUMEN

PURPOSE: To enable free-breathing whole-heart 3D T2 mapping with high isotropic resolution in a clinically feasible and predictable scan time. This 3D motion-corrected undersampled signal matched (MUST) T2 map is achieved by combining an undersampled motion-compensated T2 -prepared Cartesian acquisition with a high-order patch-based reconstruction. METHODS: The 3D MUST-T2 mapping acquisition consists of an electrocardiogram-triggered, T2 -prepared, balanced SSFP sequence with nonselective saturation pulses. Three undersampled T2 -weighted volumes are acquired using a 3D Cartesian variable-density sampling with increasing T2 preparation times. A 2D image-based navigator is used to correct for respiratory motion of the heart and allow 100% scan efficiency. Multicontrast high-dimensionality undersampled patch-based reconstruction is used in concert with dictionary matching to generate 3D T2 maps. The proposed framework was evaluated in simulations, phantom experiments, and in vivo (10 healthy subjects, 2 patients) with 1.5-mm3 isotropic resolution. Three-dimensional MUST-T2 was compared against standard multi-echo spin-echo sequence (phantom) and conventional breath-held single-shot 2D SSFP T2 mapping (in vivo). RESULTS: Three-dimensional MUST-T2 showed high accuracy in phantom experiments (R2 > 0.99). The precision of T2 values was similar for 3D MUST-T2 and 2D balanced SSFP T2 mapping in vivo (5 ± 1 ms versus 4 ± 2 ms, P = .52). Slightly longer T2 values were observed with 3D MUST-T2 in comparison to 2D balanced SSFP T2 mapping (50.7 ± 2 ms versus 48.2 ± 1 ms, P < .05). Preliminary results in patients demonstrated T2 values in agreement with literature values. CONCLUSION: The proposed approach enables free-breathing whole-heart 3D T2 mapping with high isotropic resolution in about 8 minutes, achieving accurate and precise T2 quantification of myocardial tissue in a clinically feasible scan time.


Asunto(s)
Corazón/diagnóstico por imagen , Imagenología Tridimensional , Imagen por Resonancia Magnética , Adulto , Algoritmos , Enfermedades Cardiovasculares/patología , Simulación por Computador , Femenino , Frecuencia Cardíaca , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Modelos Teóricos , Movimiento (Física) , Miocardio/patología , Fantasmas de Imagen , Respiración
4.
NMR Biomed ; 33(12): e4253, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32026547

RESUMEN

BACKGROUND: To evaluate accelerated multi-contrast volumetric imaging with isotropic resolution reconstructed using low-rank and spatially varying edge-preserving constrained compressed sensing parallel imaging reconstruction (CP-LASER), for assessing infarct heterogeneity on post-infarction patients as a precursor to studies of utility for predicting ventricular arrhythmias. METHODS: Eleven patients with prior myocardial infarction were included in the study. All subjects underwent cardiovascular magnetic resonance (CMR) scans including conventional two-dimensional late gadolinium enhancement (2D LGE) and three-dimensional multi-contrast late enhancement (3D MCLE) post-contrast. The extent of the infarct core and peri-infarct gray zone of a limited mid-ventricular slab were derived respectively by analyzing MCLE images with an isotropic resolution of 2.2 mm and an anisotropic resolution of 2.2×2.2×8.8 mm 3 , and LGE images with a resolution of 1.37×2.7×8 mm 3 ; the respective measures across all subjects were statistically compared. RESULTS: Using 3D MCLE, the infarct core size measured with isotropic resolution was similar to that measured with anisotropic resolution, while the peri-infarct gray zone size measured with isotropic resolution was smaller than that measured with anisotropic resolution ( p<0.001 , Cohen's dz=1.33 ). Isotropic 3D MCLE yielded a significantly smaller measure of the peri-infarct gray zone size than conventional 2D LGE ( p=0.0016 , Cohen's dz=1.20 ). Overall, we have successfully shown the utility of isotropic 3D MCLE in a pilot patient study. Our results suggest that smaller voxels lead to more accurate differentiation between isotropic 3D MCLE-derived gray zone and core infarct because of diminished partial volume effect. CONCLUSION: The CP-LASER accelerated 3D MCLE with isotropic resolution can be used in patients and yields excellent delineation of infarct and peri-infarct gray zone characteristics.


Asunto(s)
Medios de Contraste/química , Imagen por Resonancia Magnética , Infarto del Miocardio/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad
5.
Magn Reson Med ; 82(2): 721-731, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31006906

RESUMEN

PURPOSE: To achieve 3D T2 w imaging of the prostate with 1-mm isotropic resolution in less than 3 min. METHODS: We devised and implemented a 3D T2 -prepared multishot balanced steady state free precession (T2 prep-bSSFP) acquisition sequence with a variable density undersampled trajectory combined with a total variation regularized iterative SENSE (TV-SENSE) reconstruction. Prospectively undersampled images of the prostate (acceleration factor R = 3) were acquired in 11 healthy subjects in an institutional review board-approved study. Image quality metrics (subjective signal-to-noise ratio, contrast, sharpness, and overall prostate image quality) were evaluated by 2 radiologists. Scores of the proposed accelerated sequence were compared using the Wilcoxon signed-rank and Kruskal-Wallis non-parametric tests to prostate images acquired using a fully sampled 3D T2 prep-bSSFP acquisition, and with clinical standard 2D and 3D turbo spin echo (TSE) T2 w acquisitions. A P-value < 0.05 was considered significant. RESULTS: The 3× accelerated 3D T2 prep-bSSFP images required a scan time (min:s) of 2:45, while the fully sampled 3D T2 prep-bSSFP and clinical standard 3D TSE images were acquired in 8:23 and 7:29, respectively. Image quality scores (contrast, sharpness, and overall prostate image quality) of the accelerated 3D T2 prep-bSSFP, fully sampled T2 prep-bSSFP, and clinical standard 3D TSE acquisitions along all 3 spatial dimensions were not significantly different (P > 0.05). CONCLUSION: 3D T2 w images of the prostate with 1-mm isotropic resolution can be acquired in less than 3 min, with image quality that is comparable to a clinical standard 3D TSE sequence but only takes a third of the acquisition time.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Próstata/diagnóstico por imagen , Adulto , Humanos , Masculino , Adulto Joven
6.
J Magn Reson Imaging ; 48(6): 1707-1716, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-29717787

RESUMEN

BACKGROUND: The progressive loss of hyaline articular cartilage due to osteoarthritis (OA) changes the functional and biochemical properties of cartilage. Measuring the T1 ρ along with the morphological assessment can potentially be used as noninvasive biomarkers in detecting early-stage OA. To correlate the biochemical and morphological data, submillimeter isotropic resolution for both studies is required. PURPOSE: To implement a high spatial resolution 3D-isotropic-MRI sequence for simultaneous assessment of morphological and biexponential T1 ρ relaxometry of human knee cartilage in vivo. STUDY TYPE: Prospective. POPULATION: Ten healthy volunteers with no known inflammation, trauma, or pain in the knee. FIELD STRENGTH/SEQUENCE: Standard FLASH sequence and customized Turbo-FLASH sequence to acquire 3D-isotropic-T1 ρ-weighted images on a 3T MRI scanner. ASSESSMENT: The mean volume and thickness along with mono- and biexponential T1 ρ relaxations were assessed in the articular cartilage of 10 healthy volunteers. STATISTICAL TESTS: Nonparametric rank-sum tests. Bland-Altman analysis and coefficient of variation. RESULTS: The mean monoexponential T1 ρ relaxation was 40.7 ± 4.8 msec, while the long and short components were 58.2 ± 3.9 msec and 6.5 ± 0.6 msec, respectively. The mean fractions of long and short T1 ρ relaxation components were 63.7 ± 5.9% and 36.3 ± 5.9%, respectively. Statistically significant (P ≤ 0.03) differences were observed in the monoexponential and long components between some of the regions of interest (ROIs). No gender differences between biexponential components were observed (P > 0.05). Mean cartilage volume and thickness were 25.9 ± 6.4 cm3 and 2.2 ± 0.7 mm, respectively. Cartilage volume (P = 0.01) and thickness (P = 0.03) were significantly higher in male than female participants across all ROIs. Bland-Altman analysis showed agreement between two morphological methods with limits of agreement between -1000 mm3 and +1100 mm3 for volume, and -0.78 mm and +0.46 mm for thickness, respectively. DATA CONCLUSION: Simultaneous assessment of morphological and multicomponent T1 ρ relaxation of knee joint with 0.7 × 0.7 × 0.7 mm isotropic spatial resolution is demonstrated in vivo. Comparison with a standard method showed that the proposed technique is suitable for assessing the volume and thickness of articular cartilage. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;48:1707-1716.


Asunto(s)
Cartílago Articular/diagnóstico por imagen , Imagenología Tridimensional/métodos , Articulación de la Rodilla/diagnóstico por imagen , Imagen por Resonancia Magnética , Adulto , Biomarcadores , Femenino , Voluntarios Sanos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Estudios Prospectivos , Reproducibilidad de los Resultados , Adulto Joven
7.
Magn Reson Med ; 78(6): 2136-2148, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28074498

RESUMEN

PURPOSE: To develop a radial, double-echo steady-state (DESS) sequence with ultra-short echo-time (UTE) capabilities for T2 measurement of short-T2 tissues along with simultaneous rapid, signal-to-noise ratio (SNR)-efficient, and high-isotropic-resolution morphological knee imaging. METHODS: THe 3D radial UTE readouts were incorporated into DESS, termed UTEDESS. Multiple-echo-time UTEDESS was used for performing T2 relaxometry for short-T2 tendons, ligaments, and menisci; and for Dixon water-fat imaging. In vivo T2 estimate repeatability and SNR efficiency for UTEDESS and Cartesian DESS were compared. The impact of coil combination methods on short-T2 measurements was evaluated by means of simulations. UTEDESS T2 measurements were compared with T2 measurements from Cartesian DESS, multi-echo spin-echo (MESE), and fast spin-echo (FSE). RESULTS: UTEDESS produced isotropic resolution images with high SNR efficiency in all short-T2 tissues. Simulations and experiments demonstrated that sum-of-squares coil combinations overestimated short-T2 measurements. UTEDESS measurements of meniscal T2 were comparable to DESS, MESE, and FSE measurements while the tendon and ligament measurements were less biased than those from Cartesian DESS. Average UTEDESS T2 repeatability variation was under 10% in all tissues. CONCLUSION: The T2 measurements of short-T2 tissues and high-resolution morphological imaging provided by UTEDESS makes it promising for studying the whole knee, both in routine clinical examinations and longitudinal studies. Magn Reson Med 78:2136-2148, 2017. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Rodilla/diagnóstico por imagen , Imagen por Resonancia Magnética , Tejido Adiposo/diagnóstico por imagen , Adulto , Algoritmos , Femenino , Voluntarios Sanos , Humanos , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Articulación de la Rodilla/diagnóstico por imagen , Ligamentos/diagnóstico por imagen , Masculino , Meniscos Tibiales/diagnóstico por imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Relación Señal-Ruido , Tendones/diagnóstico por imagen
8.
J Magn Reson Imaging ; 40(4): 796-803, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24151247

RESUMEN

PURPOSE: To compare a balanced steady-state free-precession sequence with a radial k-space trajectory and alternating repetition time fat suppression (Radial-ATR) with other currently used fat-suppressed 3D sequences for evaluating the articular cartilage of the knee joint at 3.0T. MATERIALS AND METHODS: Radial-ATR, fast spin-echo (FSE-Cube), gradient recall-echo acquired in the steady-state (GRASS), and spoiled gradient recall-echo (SPGR) sequences with similar voxel volumes and identical scan times were performed at 3.0T on both knee joints of five volunteers. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements were performed for all sequences using a double acquisition method and compared using Mann-Whitney Wilcoxon tests. Radial-ATR sequences with 0.3 mm and 0.4 mm isotropic resolution were also performed on the knee joints of seven volunteers and three patients with osteoarthritis. RESULTS: Average SNR values for cartilage, synovial fluid, and bone marrow were 54.7, 153.3, and 12.9, respectively, for Radial ATR, 30.8, 44.1, and 1.9, respectively, for FSE-Cube, 13.3, 46.9, and 3.3, respectively, for GRASS, and 19.1, 8.1, and 2.1, respectively, for SPGR. Average CNR values between cartilage and synovial fluid and between cartilage and bone marrow were 98.6 and 41.8, respectively, for VIPR-ATR, 13.4 and 28.8, respectively, for FSE-Cube, 33.6 and 10.0, respectively, for GRASS, and 11.0 and 16.9, respectively, for SPGR. Radial-ATR had significantly higher (P < 0.001) cartilage, synovial fluid, and bone marrow SNR and significantly higher (P < 0.01) CNR between cartilage and synovial fluid and between cartilage and bone marrow than FSE-Cube, GRASS, and SPGR. Radial-ATR provided excellent visualization of articular cartilage at high isotropic resolution with no image degradation due to off-resonance banding artifacts. CONCLUSION: Radial-ATR had superior SNR efficiency to other fat-suppressed 3D cartilage imaging sequences and produced high isotropic resolution images of the knee joint which could be used for evaluating articular cartilage at 3.0T.


Asunto(s)
Cartílago Articular/patología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Articulación de la Rodilla/patología , Imagen por Resonancia Magnética/métodos , Osteoartritis de la Rodilla/patología , Adulto , Algoritmos , Anisotropía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
9.
Phys Med Biol ; 69(3)2024 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-38168021

RESUMEN

Objective. Imaging of superparamagnetic iron oxide nanoparticles based on their non-linear response to alternating magnetic fields shows promise for imaging cells and vasculature in healthy and diseased tissue. Such imaging can be achieved through x-space reconstruction typically along a unidirectional Cartesian trajectory, which rapidly convolutes the particle distribution with a 'anisotropic blurring' point spread function (PSF), leading to images with anisotropic resolution.Approach. Here we propose combining the time domine-system matrix and x-space reconstruction methods into a forward model, where the output of the forward model is the PSF-blurred x-space reconstructed image. We then treat the blur as an inverse problem solved by Kaczmarz iteration.Main results. After we have proposed the method optimization, the normal resolution of simulation and device images has been increased from 3.5 mm and 5.25 mm to 1.5 mm and 3.25 mm, which has reached the level in the tangential resolution. Quantitative indicators of image quality such as PSNR and SSIM have also been greatly improved.Significance. Simulation and imaging of real phantoms indicate that our approach provides better isotropic resolution and image quality than the x-space method alone or other methods for removing PSF blur. Using our proposed method to optimize the image quality of x-space reconstructed images using unidirectional Cartesian trajectories, it will promote the clinical application of MPI in the future.


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador , Procesamiento de Imagen Asistido por Computador/métodos , Campos Magnéticos , Fantasmas de Imagen , Nanopartículas Magnéticas de Óxido de Hierro
10.
Tomography ; 9(2): 721-735, 2023 03 24.
Artículo en Inglés | MEDLINE | ID: mdl-37104129

RESUMEN

This paper investigates the effect of anisotropic resolution on the image textural features of pharmacokinetic (PK) parameters of a murine glioma model using dynamic contrast-enhanced (DCE) MR images acquired with an isotropic resolution at 7T with pre-contrast T1 mapping. The PK parameter maps of whole tumors at isotropic resolution were generated using the two-compartment exchange model combined with the three-site-two-exchange model. The textural features of these isotropic images were compared with those of simulated, thick-slice, anisotropic images to assess the influence of anisotropic voxel resolution on the textural features of tumors. The isotropic images and parameter maps captured distributions of high pixel intensity that were absent in the corresponding anisotropic images with thick slices. A significant difference was observed in 33% of the histogram and textural features extracted from anisotropic images and parameter maps, compared to those extracted from corresponding isotropic images. Anisotropic images in different orthogonal orientations demonstrated 42.1% of the histogram and textural features to be significantly different from those of isotropic images. This study demonstrates that the anisotropy of voxel resolution needs to be carefully considered when comparing the textual features of tumor PK parameters and contrast-enhanced images.


Asunto(s)
Glioma , Imagen por Resonancia Magnética , Animales , Ratones , Imagen por Resonancia Magnética/métodos , Aumento de la Imagen/métodos , Glioma/diagnóstico por imagen , Glioma/patología
11.
Front Cardiovasc Med ; 10: 1305649, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38099228

RESUMEN

Aim: The purpose of this study was to investigate the clinical application of Compressed SENSE accelerated single-breath-hold LGE with 3D isotropic resolution compared to conventional LGE imaging acquired in multiple breath-holds. Material & Methods: This was a retrospective, single-center study including 105 examinations of 101 patients (48.2 ± 16.8 years, 47 females). All patients underwent conventional breath-hold and 3D single-breath-hold (0.96 × 0.96 × 1.1 mm3 reconstructed voxel size, Compressed SENSE factor 6.5) LGE sequences at 1.5 T in clinical routine for the evaluation of ischemic or non-ischemic cardiomyopathies. Two radiologists independently evaluated the left ventricle (LV) for the presence of hyperenhancing lesions in each sequence, including localization and transmural extent, while assessing their scar edge sharpness (SES). Confidence of LGE assessment, image quality (IQ), and artifacts were also rated. The impact of LV ejection fraction (LVEF), heart rate, body mass index (BMI), and gender as possible confounders on IQ, artifacts, and confidence of LGE assessment was evaluated employing ordinal logistic regression analysis. Results: Using 3D single-breath-hold LGE readers detected more hyperenhancing lesions compared to conventional breath-hold LGE (n = 246 vs. n = 216 of 1,785 analyzed segments, 13.8% vs. 12.1%; p < 0.0001), pronounced at subendocardial, midmyocardial, and subepicardial localizations and for 1%-50% of transmural extent. SES was rated superior in 3D single-breath-hold LGE (4.1 ± 0.8 vs. 3.3 ± 0.8; p < 0.001). 3D single-breath-hold LGE yielded more artifacts (3.8 ± 1.0 vs. 4.0 ± 3.8; p = 0.002) whereas IQ (4.1 ± 1.0 vs. 4.2 ± 0.9; p = 0.122) and confidence of LGE assessment (4.3 ± 0.9 vs. 4.3 ± 0.8; p = 0.374) were comparable between both techniques. Female gender negatively influenced artifacts in 3D single-breath-hold LGE (p = 0.0028) while increased heart rate led to decreased IQ in conventional breath-hold LGE (p = 0.0029). Conclusions: In clinical routine, Compressed SENSE accelerated 3D single-breath-hold LGE yields image quality and confidence of LGE assessment comparable to conventional breath-hold LGE while providing improved delineation of smaller LGE lesions with superior scar edge sharpness. Given the fast acquisition of 3D single-breath-hold LGE, the technique holds potential to drastically reduce the examination time of CMR.

12.
J Biomed Opt ; 24(8): 1-5, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31385482

RESUMEN

We demonstrate a propagating-path uniformly scanned light sheet excitation (PULSE) microscopy based on the oscillation of voice coil motor that can rapidly drive a thin light sheet along its propagation direction. By synchronizing the rolling shutter of a camera with the motion of laser sheet, we can obtain a uniform plane-illuminated image far beyond the confocal range of Gaussian beam. A stable 1.7-µm optical sectioning under a 3.3 mm × 3.3 mm wide field of view (FOV) has been achieved for up to 20 Hz volumetric imaging of large biological specimens. PULSE method transforms the extent of plane illumination from one intrinsically limited by the short confocal range (µm scale) to one defined by the motor oscillation range (mm scale). Compared to the conventional Gaussian light sheet imaging, our method greatly mitigates the compromise of axial resolution and successfully extends the FOV over 100 times. We demonstrate the applications of PULSE method by rapidly imaging cleared mouse spinal cord and live zebrafish larva at isotropic subcellular resolution.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Microscopía Fluorescente/métodos , Médula Espinal/diagnóstico por imagen , Algoritmos , Animales , Imagenología Tridimensional , Luz , Ratones , Distribución Normal , Óptica y Fotónica , Oscilometría , Pez Cebra
13.
Ultramicroscopy ; 160: 230-238, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26555323

RESUMEN

Electron tomography is an invaluable method for 3D cellular imaging. The technique is, however, limited by the specimen geometry, with a loss of resolution due to a restricted tilt range, an increase in specimen thickness with tilt, and a resultant need for subjective and time-consuming manual segmentation. Here we show that 3D reconstructions of needle-shaped biological samples exhibit isotropic resolution, facilitating improved automated segmentation and feature detection. By using scanning transmission electron tomography, with small probe convergence angles, high spatial resolution is maintained over large depths of field and across the tilt range. Moreover, the application of compressed sensing methods to the needle data demonstrates how high fidelity reconstructions may be achieved with far fewer images (and thus greatly reduced dose) than needed by conventional methods. These findings open the door to high fidelity electron tomography over critically relevant length-scales, filling an important gap between existing 3D cellular imaging techniques.


Asunto(s)
Microscopía Electrónica de Transmisión de Rastreo/métodos , Algoritmos , Animales , Encéfalo/ultraestructura , Compresión de Datos/métodos , Compresión de Datos/estadística & datos numéricos , Análisis de Fourier , Técnicas de Preparación Histocitológica , Procesamiento de Imagen Asistido por Computador/métodos , Procesamiento de Imagen Asistido por Computador/estadística & datos numéricos , Imagenología Tridimensional/métodos , Imagenología Tridimensional/estadística & datos numéricos , Masculino , Microscopía Electrónica de Transmisión de Rastreo/estadística & datos numéricos , Ratas , Ratas Sprague-Dawley