Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Circulation ; 141(19): 1527-1537, 2020 05 12.
Artigo em Inglês | MEDLINE | ID: mdl-32272848

RESUMO

BACKGROUND: This study aimed to compare echocardiographic findings in low-risk patients with severe aortic stenosis after surgical aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR). METHODS: The PARTNER 3 trial (Placement of Aortic Transcatheter Valves) randomized 1000 patients with severe aortic stenosis and low surgical risk to undergo either transfemoral TAVR with the balloon-expandable SAPIEN 3 valve or SAVR. Transthoracic echocardiograms obtained at baseline and at 30 days and 1 year after the procedure were analyzed by a consortium of 2 echocardiography core laboratories. RESULTS: The percentage of moderate or severe aortic regurgitation (AR) was low and not statistically different between the TAVR and SAVR groups at 30 days (0.8% versus 0.2%; P=0.38). Mild AR was more frequent after TAVR than SAVR at 30 days (28.8% versus 4.2%; P<0.001). At 1 year, mean transvalvular gradient (13.7±5.6 versus 11.6±5.0 mm Hg; P=0.12) and aortic valve area (1.72±0.37 versus 1.76±0.42 cm2; P=0.12) were similar in TAVR and SAVR. The percentage of severe prosthesis-patient mismatch at 30 days was low and similar between TAVR and SAVR (4.6 versus 6.3%; P=0.30). Valvulo-arterial impedance (Zva), which reflects total left ventricular hemodynamic burden, was lower with TAVR than SAVR at 1 year (3.7±0.8 versus 3.9±0.9 mm Hg/mL/m2; P<0.001). Tricuspid annulus plane systolic excursion decreased and the percentage of moderate or severe tricuspid regurgitation increased from baseline to 1 year in SAVR but remained unchanged in TAVR. Irrespective of treatment arm, high Zva and low tricuspid annulus plane systolic excursion, but not moderate to severe AR or severe prosthesis-patient mismatch, were associated with increased risk of the composite end point of mortality, stroke, and rehospitalization at 1 year. CONCLUSIONS: In patients with severe aortic stenosis and low surgical risk, TAVR with the SAPIEN 3 valve was associated with similar percentage of moderate or severe AR compared with SAVR but higher percentage of mild AR. Transprosthetic gradients, valve areas, percentage of severe prosthesis-patient mismatch, and left ventricular mass regression were similar in TAVR and SAVR. SAVR was associated with significant deterioration of right ventricular systolic function and greater tricuspid regurgitation, which persisted at 1 year. High Zva and low tricuspid annulus plane systolic excursion were associated with worse outcome at 1 year whereas AR and severe prosthesis-patient mismatch were not. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02675114.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Ecocardiografia , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Masculino , América do Norte , Valor Preditivo dos Testes , Desenho de Prótese , Falha de Prótese , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
2.
Circ Res ; 125(4): 449-466, 2019 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-31154939

RESUMO

RATIONALE: Pulmonary hypertension (PH) due to left heart disease (LHD), or group 2 PH, is the most prevalent form of PH worldwide. PH due to LHD is often associated with metabolic syndrome (MetS). In 12% to 13% of cases, patients with PH due to LHD display vascular remodeling of pulmonary arteries (PAs) associated with poor prognosis. Unfortunately, the underlying mechanisms remain unknown; PH-targeted therapies for this group are nonexistent, and the development of a new preclinical model is crucial. Among the numerous pathways dysregulated in MetS, inflammation plays also a critical role in both PH and vascular remodeling. OBJECTIVE: We hypothesized that MetS and inflammation may trigger the development of vascular remodeling in group 2 PH. METHODS AND RESULTS: Using supracoronary aortic banding, we induced diastolic dysfunction in rats. Then we induced MetS by a combination of high-fat diet and olanzapine treatment. We used metformin treatment and anti-IL-6 (interleukin-6) antibodies to inhibit the IL-6 pathway. Compared with sham conditions, only supracoronary aortic banding+MetS rats developed precapillary PH, as measured by both echocardiography and right/left heart catheterization. PH in supracoronary aortic banding+MetS was associated with macrophage accumulation and increased IL-6 production in lung. PH was also associated with STAT3 (signal transducer and activator of transcription 3) activation and increased proliferation of PA smooth muscle cells, which contributes to remodeling of distal PA. We reported macrophage accumulation, increased IL-6 levels, and STAT3 activation in the lung of group 2 PH patients. In vitro, IL-6 activates STAT3 and induces human PA smooth muscle cell proliferation. Metformin treatment decreased inflammation, IL-6 levels, STAT3 activation, and human PA smooth muscle cell proliferation. In vivo, in the supracoronary aortic banding+MetS animals, reducing IL-6, either by anti-IL-6 antibody or metformin treatment, reversed pulmonary vascular remodeling and improve PH due to LHD. CONCLUSIONS: We developed a new preclinical model of group 2 PH by combining MetS with LHD. We showed that MetS exacerbates group 2 PH. We provided evidence for the importance of the IL-6-STAT3 pathway in our experimental model of group 2 PH and human patients.


Assuntos
Modelos Animais de Doenças , Hipertensão Pulmonar/patologia , Síndrome Metabólica/complicações , Disfunção Ventricular/complicações , Animais , Células Cultivadas , Dieta Hiperlipídica/efeitos adversos , Humanos , Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/metabolismo , Interleucina-6/genética , Interleucina-6/metabolismo , Macrófagos/metabolismo , Masculino , Síndrome Metabólica/etiologia , Olanzapina/toxicidade , Artéria Pulmonar/metabolismo , Artéria Pulmonar/patologia , Ratos , Ratos Wistar , Remodelação Vascular
3.
Lancet ; 394(10213): 2002-2011, 2019 11 30.
Artigo em Inglês | MEDLINE | ID: mdl-31708188

RESUMO

BACKGROUND: Tricuspid regurgitation is a prevalent disease associated with high morbidity and mortality, with few treatment options. The aim of the TRILUMINATE trial is to evaluate the safety and effectiveness of TriClip, a minimally invasive transcatheter tricuspid valve repair system, for reducing tricuspid regurgitation. METHODS: The TRILUMINATE trial is a prospective, multicentre, single-arm study in 21 sites in Europe and the USA. Patients with moderate or greater triscuspid regurgitation, New York Heart Association class II or higher, and who were adequately treated per applicable standards were eligible for enrolment. Patients were excluded if they had systolic pulmonary artery pressure of more than 60 mm Hg, a previous tricuspid valve procedure, or a cardiovascular implantable electronic device that would inhibit TriClip placement. Participants were treated using a clip-based edge-to-edge repair technique with the TriClip tricuspid valve repair system. Tricuspid regurgitation was graded using a five-class grading scheme (mild, moderate, severe, massive, and torrential) that expanded on the standard American Society of Echocardiography grading scheme. The primary efficacy endpoint was a reduction in tricuspid regurgitation severity by at least one grade at 30 days post procedure, with a performance goal of 35%, analysed in all patients who had an attempted tricuspid valve repair procedure upon femoral vein puncture. The primary safety endpoint was a composite of major adverse events at 6 months, with a performance goal of 39%. Patients were excluded from the primary safety analysis if they did not reach 6-month follow-up and did not have a major adverse event during previous follow-ups. The trial has completed enrolment and follow-up is ongoing; it is registered with ClinicalTrials.gov, number NCT03227757. FINDINGS: Between Aug 1, 2017, and Nov 29, 2018, 85 patients (mean age 77·8 years [SD 7·9]; 56 [66%] women) were enrolled and underwent successful TriClip implantation. Tricuspid regurgitation severity was reduced by at least one grade at 30 days in 71 (86%) of 83 patients who had available echocardiogram data and imaging. The one-sided lower 97·5% confidence limit was 76%, which was greater than the prespecified performance goal of 35% (p<0·0001). One patient withdrew before 6-month follow-up without having had a major adverse event and was excluded from analysis of the primary safety endpoint. At 6 months, three (4%) of 84 patients experienced a major adverse event, which was less than the prespecified performance goal of 39% (p<0·0001). Single leaflet attachment occurred in five (7%) of 72 patients. No periprocedural deaths, conversions to surgery, device embolisations, myocardial infarctions, or strokes occurred. At 6 months, all-cause mortality had occurred in four (5%) of 84 patients. INTERPRETATION: The TriClip system appears to be safe and effective at reducing tricuspid regurgitation by at least one grade. This reduction could translate to significant clinical improvement at 6 months post procedure. FUNDING: Abbott.


Assuntos
Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Tricúspide/cirurgia , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Feminino , Seguimentos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Masculino , Complicações Pós-Operatórias , Estudos Prospectivos , Índice de Gravidade de Doença , Instrumentos Cirúrgicos , Resultado do Tratamento
4.
Eur Heart J ; 40(17): 1362-1373, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-30395215

RESUMO

AIMS: Calcific aortic valve stenosis (CAVS) is characterized by a fibrocalcific process. Studies have shown an association between CAVS and the activation of platelets. It is believed that shear stress associated with CAVS promotes the activation of platelets. However, whether platelets actively participate to the mineralization of the aortic valve (AV) and the progression of CAVS is presently unknown. To identify the role of platelets into the pathobiology of CAVS. METHODS AND RESULTS: Explanted control non-mineralized and mineralized AVs were examined by scanning electron microscope (SEM) for the presence of activated platelets. In-depth functional assays were carried out with isolated human valve interstitial cells (VICs) and platelets as well as in LDLR-/- apoB100/100 IGFII (IGFII) mice. Scanning electron microscope and immunogold markings for glycoprotein IIb/IIIa (GPIIb/IIIa) revealed the presence of platelet aggregates with fibrin in endothelium-denuded areas of CAVS. In isolated VICs, collagen-activated platelets induced an osteogenic programme. Platelet-derived adenosine diphosphate induced the release of autotaxin (ATX) by VICs. The binding of ATX to GPIIb/IIIa of platelets generated lysophosphatidic acid (LysoPA) with pro-osteogenic properties. In IGFII mice with CAVS, platelet aggregates were found at the surface of AVs. Administration of activated platelets to IGFII mice accelerated the development of CAVS by 2.1-fold, whereas a treatment with Ki16425, an antagonist of LysoPA receptors, prevented platelet-induced mineralization of the AV and the progression of CAVS. CONCLUSIONS: These findings suggest a novel role for platelets in the progression of CAVS.


Assuntos
Estenose da Valva Aórtica/metabolismo , Valva Aórtica/patologia , Plaquetas/metabolismo , Calcinose/metabolismo , Osteogênese , Animais , Valva Aórtica/metabolismo , Valva Aórtica/ultraestrutura , Apolipoproteína B-100/metabolismo , Progressão da Doença , Humanos , Integrina beta3/metabolismo , Lisofosfolipídeos/metabolismo , Camundongos , Microscopia Eletrônica de Varredura/métodos , Diester Fosfórico Hidrolases/metabolismo , Glicoproteína IIb da Membrana de Plaquetas/metabolismo
5.
Circulation ; 132(10): 932-43, 2015 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-26162916

RESUMO

BACKGROUND: Right ventricular (RV) failure is the most important factor of both morbidity and mortality in pulmonary arterial hypertension (PAH). However, the underlying mechanisms resulting in the failed RV in PAH remain unknown. There is growing evidence that angiogenesis and microRNAs are involved in PAH-associated RV failure. We hypothesized that microRNA-126 (miR-126) downregulation decreases microvessel density and promotes the transition from a compensated to a decompensated RV in PAH. METHODS AND RESULTS: We studied RV free wall tissues from humans with normal RV (n=17), those with compensated RV hypertrophy (n=8), and patients with PAH with decompensated RV failure (n=14). Compared with RV tissues from patients with compensated RV hypertrophy, patients with decompensated RV failure had decreased miR-126 expression (quantitative reverse transcription-polymerase chain reaction; P<0.01) and capillary density (CD31(+) immunofluorescence; P<0.001), whereas left ventricular tissues were not affected. miR-126 downregulation was associated with increased Sprouty-related EVH1 domain-containing protein 1 (SPRED-1), leading to decreased activation of RAF (phosphorylated RAF/RAF) and mitogen-activated protein kinase (MAPK); (phosphorylated MAPK/MAPK), thus inhibiting the vascular endothelial growth factor pathway. In vitro, Matrigel assay showed that miR-126 upregulation increased angiogenesis of primary cultured endothelial cells from patients with decompensated RV failure. Furthermore, in vivo miR-126 upregulation (mimic intravenous injection) improved cardiac vascular density and function of monocrotaline-induced PAH animals. CONCLUSIONS: RV failure in PAH is associated with a specific molecular signature within the RV, contributing to a decrease in RV vascular density and promoting the progression to RV failure. More importantly, miR-126 upregulation in the RV improves microvessel density and RV function in experimental PAH.


Assuntos
Regulação para Baixo/fisiologia , Insuficiência Cardíaca/metabolismo , Hipertensão Pulmonar/metabolismo , MicroRNAs/metabolismo , Disfunção Ventricular Direita/metabolismo , Adulto , Idoso , Animais , Células Cultivadas , Feminino , Insuficiência Cardíaca/diagnóstico , Humanos , Hipertensão Pulmonar/diagnóstico , Masculino , Pessoa de Meia-Idade , Ratos , Ratos Sprague-Dawley , Disfunção Ventricular Direita/diagnóstico
6.
Circulation ; 132(8): 677-90, 2015 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-26224810

RESUMO

BACKGROUND: Mendelian randomization studies have highlighted that lipoprotein(a) [Lp(a)] was associated with calcific aortic valve disease (CAVD). Lp(a) transports oxidized phospholipids with a high content in lysophosphatidylcholine. Autotaxin (ATX) transforms lysophosphatidylcholine into lysophosphatidic acid. We hypothesized that ATX-lysophosphatidic acid could promote inflammation/mineralization of the aortic valve. METHODS AND RESULTS: We have documented the expression of ATX in control and mineralized aortic valves. By using different approaches, we have also investigated the role of ATX-lysophosphatidic acid in the mineralization of isolated valve interstitial cells and in a mouse model of CAVD. Enzyme-specific ATX activity was elevated by 60% in mineralized aortic valves in comparison with control valves. Immunohistochemistry studies showed a high level of ATX in mineralized aortic valves, which colocalized with oxidized phospholipids and apolipoprotein(a). We detected a high level of ATX activity in the Lp(a) fraction in circulation. Interaction between ATX and Lp(a) was confirmed by in situ proximity ligation assay. Moreover, we documented that valve interstitial cells also expressed ATX in CAVD. We showed that ATX-lysophosphatidic acid promotes the mineralization of the aortic valve through a nuclear factor κB/interleukin 6/bone morphogenetic protein pathway. In LDLR(-/-)/ApoB(100/100)/IGFII mice, ATX is overexpressed and lysophosphatidic acid promotes a strong deposition of hydroxyapatite of calcium in aortic valve leaflets and accelerates the development of CAVD. CONCLUSIONS: ATX is transported in the aortic valve by Lp(a) and is also secreted by valve interstitial cells. ATX-lysophosphatidic acid promotes inflammation and mineralization of the aortic valve and thus could represent a novel therapeutic target in CAVD.


Assuntos
Estenose da Valva Aórtica/metabolismo , Valva Aórtica/metabolismo , Lipoproteína(a)/biossíntese , Diester Fosfórico Hidrolases/biossíntese , Idoso , Animais , Valva Aórtica/patologia , Estenose da Valva Aórtica/patologia , Feminino , Humanos , Inflamação/metabolismo , Inflamação/patologia , Lipoproteína(a)/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Pessoa de Meia-Idade
7.
Artigo em Inglês | MEDLINE | ID: mdl-38693866

RESUMO

AIMS: Evaluation of left and right ventricular longitudinal systolic function may enhance risk stratification following aortic valve replacement (AVR). The study objective was to evaluate the changes in left and right ventricular longitudinal systolic function and RV-pulmonary artery (RV-PA) coupling from baseline to 30-days and 1-year after aortic valve replacement (AVR). METHODS AND RESULTS: LV longitudinal strain (LS), tricuspid annulus plane systolic excursion (TAPSE), and RV-PA coupling were evaluated in patients from the PARTNER-2A surgical AVR (SAVR) arm (n=985) and from the PARTNER-2 SAPIEN-3 registry (n=719). TAPSE and RV-PA coupling decreased significantly following SAVR, but remained stable following TAVR. Lower LV LS, TAPSE, or RV-PA coupling at baseline were associated with increased risk of the composite of death, hospitalization, and stroke at 5-years (Adjusted-HRs for LV LS<15%: 1.24 95%CI 1.05-1.45, p=0.001; TAPSE<14mm: 1.44 95%CI 1.21-1.73, p<0.001; RV/PA coupling<0.55mm/mmHg: 1.32 95% CI 1.07-1.63, p=0.011). Reduced TAPSE at baseline was the most powerful predictor of the composite endpoint at 5-years. Patients with LV ejection fraction <50% at baseline had increased risk of the primary endpoint with SAVR (HR: 1.34, 95%CI 1.08-1.68, p=0.009) but not with TAVR (HR: 1.12, 95%CI 0.88-1.42). Lower RV-PA coupling at 30-days showed the strongest association with cardiac mortality. CONCLUSION: SAVR but not TAVR was associated with a marked deterioration in RV longitudinal systolic function and RV-PA coupling. Lower TAPSE and RV-PA coupling at 30-days were associated with inferior clinical outcomes at 5-years. In patients with LVEF<50%, TAVR was associated with superior 5-year outcomes.

8.
Ann Thorac Surg ; 117(6): 1164-1171, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38316377

RESUMO

BACKGROUND: Our objective was to compare the impact of patient-prosthesis mismatch (PPM) for 2 years after surgical aortic valve replacement within the prospective, randomized Placement of Aortic Transcatheter Valves (PARTNER) trials. METHODS: Surgical aortic valve replacement patients from the PARTNER 1, 2, and 3 trials were included. PPM was classified as moderate (indexed effective orifice area ≤0.85 cm2/m2) or severe (indexed effective orifice area ≤0.65 cm2/m2). The primary endpoint was the composite of all-cause death and heart failure rehospitalization at 2 years. RESULTS: By the predicted PPM method (PPMP), 59.1% had no PPM, 38.8% moderate PPM, and 2.1% severe PPM; whereas by the measured PPM method (PPMM), 42.4% had no PPM, 36.0% moderate, and 21.6% severe. Patients with no PPMP (23.6%) had a lower rate of the primary endpoint compared with patients with moderate (28.2%, P = .03) or severe PPMP (38.8%, P = .02). Using the PPMM method, there was no difference between the no (17.7%) and moderate PPMM groups (21.1%) in the primary outcome (P = .16). However, those with no PPMM or moderate PPMM were improved compared with severe PPMM (27.4%, P < .001 and P = .02, respectively). CONCLUSIONS: Severe PPM analyzed by PPMP was only 2.1% for surgical aortic valve replacement patients. The PPMM method overestimated the incidence of severe PPM relative to PPMP, but was also associated with worse outcome. There was higher all-cause mortality in patients with severe PPM, thus surgical techniques to minimize PPM remain critical.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Humanos , Feminino , Masculino , Idoso , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Desenho de Prótese , Idoso de 80 Anos ou mais , Resultado do Tratamento , Ajuste de Prótese
9.
J Am Coll Cardiol ; 81(18): 1766-1776, 2023 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-37137586

RESUMO

BACKGROUND: Surgical management of isolated tricuspid regurgitation (TR) is associated with high morbidity and mortality, thereby creating a significant need for a lower-risk transcatheter solution. OBJECTIVES: The single-arm, multicenter, prospective CLASP TR (Edwards PASCAL TrAnScatheter Valve RePair System in Tricuspid Regurgitation [CLASP TR] Early Feasibility Study) evaluated 1-year outcomes of the PASCAL transcatheter valve repair system (Edwards Lifesciences) to treat TR. METHODS: Study inclusion required a previous diagnosis of severe or greater TR and persistent symptoms despite medical treatment. An independent core laboratory evaluated echocardiographic results, and a clinical events committee adjudicated major adverse events. The study evaluated primary safety and performance outcomes, with echocardiographic, clinical, and functional endpoints. Study investigators report 1-year all-cause mortality and heart failure hospitalization rates. RESULTS: Sixty-five patients were enrolled: mean age of 77.4 years; 55.4% female; and 97.0% with severe to torrential TR. At 30 days, cardiovascular mortality was 3.1%, the stroke rate was 1.5%, and no device-related reinterventions were reported. Between 30 days and 1 year, there were an additional 3 cardiovascular deaths (4.8%), 2 strokes (3.2%), and 1 unplanned or emergency reintervention (1.6%). One-year postprocedure, TR severity significantly reduced (P < 0.001), with 31 of 36 (86.0%) patients achieving moderate or less TR; 100% had at least 1 TR grade reduction. Freedom from all-cause mortality and heart failure hospitalization by Kaplan-Meier analyses were 87.9% and 78.5%, respectively. Their New York Heart Association functional class significantly improved (P < 0.001) with 92% in class I or II, 6-minute walk distance increased by 94 m (P = 0.014), and overall Kansas City Cardiomyopathy Questionnaire scores improved by 18 points (P < 0.001). CONCLUSIONS: The PASCAL system demonstrated low complication and high survival rates, with significant and sustained improvements in TR, functional status, and quality of life at 1 year. (Edwards PASCAL TrAnScatheter Valve RePair System in Tricuspid Regurgitation [CLASP TR] Early Feasibility Study [CLASP TR EFS]; NCT03745313).


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Idoso , Masculino , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Índice de Gravidade de Doença
10.
Eur Heart J Cardiovasc Imaging ; 24(1): 46-58, 2022 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-35613021

RESUMO

AIMS: This study sought to compare cardiac magnetic resonance (CMR) characteristics according to different flow/gradient patterns of aortic stenosis (AS) and to evaluate their prognostic value in patients with low-gradient AS. METHODS AND RESULTS: This international prospective multicentric study included 147 patients with low-gradient moderate to severe AS who underwent comprehensive CMR evaluation of left ventricular global longitudinal strain (LVGLS), extracellular volume fraction (ECV), and late gadolinium enhancement (LGE). All patients were classified as followings: classical low-flow low-gradient (LFLG) [mean gradient (MG) < 40 mmHg and left ventricular ejection fraction (LVEF) < 50%]; paradoxical LFLG [MG < 40 mmHg, LVEF ≥ 50%, and stroke volume index (SVi) < 35 ml/m2]; and normal-flow low-gradient (MG < 40 mmHg, LVEF ≥ 50%, and SVi ≥ 35 ml/m2). Patients with classical LFLG (n = 90) had more LV adverse remodelling including higher ECV, and higher LGE and volume, and worst LVGLS. Over a median follow-up of 2 years, 43 deaths and 48 composite outcomes of death or heart failure hospitalizations occurred. Risks of adverse events increased per tertile of LVGLS: hazard ratio (HR) = 1.50 [95% CI, 1.02-2.20]; P = 0.04 for mortality; HR = 1.45 [1.01-2.09]; P < 0.05 for composite outcome; per tertile of ECV, HR = 1.63 [1.07-2.49]; P = 0.02 for mortality; HR = 1.54 [1.02-2.33]; P = 0.04 for composite outcome. LGE presence also associated with higher mortality, HR = 2.27 [1.01-5.11]; P < 0.05 and composite outcome, HR = 3.00 [1.16-7.73]; P = 0.02. The risk of mortality and the composite outcome increased in proportion to the number of impaired components (i.e. LVGLS, ECV, and LGE) with multivariate adjustment. CONCLUSIONS: In this international prospective multicentric study of low-gradient AS, comprehensive CMR assessment provides independent prognostic value that is cumulative and incremental to clinical and echocardiographic characteristics.


Assuntos
Estenose da Valva Aórtica , Função Ventricular Esquerda , Humanos , Volume Sistólico , Estudos Prospectivos , Meios de Contraste , Imagem Cinética por Ressonância Magnética/métodos , Gadolínio , Prognóstico , Espectroscopia de Ressonância Magnética
11.
JACC Cardiovasc Interv ; 15(19): 1921-1932, 2022 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-36202561

RESUMO

BACKGROUND: Tricuspid regurgitation (TR) is prevalent and undertreated, with mortality and morbidity increasing with TR severity. Given poor outcomes with medical therapy and high in-hospital mortality for isolated tricuspid valve surgery, emerging transcatheter repair devices offer a promising alternative. OBJECTIVES: The Edwards Cardioband Tricuspid Valve Reconstruction System Early Feasibility study (NCT03382457) evaluates the treatment of functional TR via annular reduction with the Cardioband Tricuspid Valve Reconstruction System (Edwards Lifesciences). METHODS: Patients with ≥ moderate functional TR were eligible for this prospective, single-arm multicenter study. At 1 year, patients were evaluated for echocardiographic parameters, clinical and quality-of-life measures, and major adverse events. RESULTS: The 37 patients enrolled had a mean age of 78 years; 76% were female; and they had ≥ severe functional (97.3%) or mixed (2.7%) TR, atrial flutter/fibrillation (97%), and New York Heart Association functional class III/IV (65%). At 1 year, 73.0% achieved ≤ moderate TR (P < 0.0001), and 73.1% had ≥2 grade reductions. Echocardiography showed significant reductions in the tricuspid annulus diameter (P < 0.0001), mean vena contracta (P < 0.0001), proximal isovelocity surface area effective regurgitant orifice area (P < 0.0001), right ventricular end-diastolic diameter (P < 0.0001), and inferior vena contracta (P = 0.0006). New York Heart Association functional class improved significantly (P < 0.0001), with 92.3% achieving class I/II, and Kansas City Cardiomyopathy Questionnaire scores improved by 19.0 points (P < 0.0001). One-year cardiovascular mortality was 8.1%, reinterventions were necessary in 5.4%, major access site complications occurred in 8.1%, and severe bleeding was noted in 35.1% of patients. Kaplan-Meier estimates of survival and freedom from heart failure rehospitalization were 85.9% and 88.7%, respectively. CONCLUSIONS: One-year experience using the Cardioband system for tricuspid valve repair shows high survival and low rehospitalization rates with durable outcomes in TR reduction and echocardiographic, clinical, and quality-of-life outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Idoso , Cateterismo Cardíaco , Estudos de Viabilidade , Feminino , Humanos , Masculino , Estudos Prospectivos , Índice de Gravidade de Doença , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
12.
J Am Coll Cardiol ; 77(3): 229-239, 2021 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-33478646

RESUMO

BACKGROUND: Tricuspid regurgitation (TR) is a frequent disease with a progressive increase in mortality as disease severity increases. Transcatheter therapies for treatment of TR may offer a safe and effective alternative to surgery in this high-risk population. OBJECTIVES: The purpose of this report was to study the 1-year outcomes with the TriClip transcatheter tricuspid valve repair system, including repair durability, clinical benefit and safety. METHODS: The TRILUMINATE trial (n = 85) is an international, prospective, single arm, multicenter study investigating safety and performance of the TriClip Tricuspid Valve Repair System in patients with moderate or greater TR. Echocardiographic assessment was performed by a core laboratory. RESULTS: At 1 year, TR was reduced to moderate or less in 71% of subjects compared with 8% at baseline (p < 0.0001). Patients experienced significant clinical improvements in New York Heart Association (NYHA) functional class I/II (31% to 83%, p < 0.0001), 6-minute walk test (272.3 ± 15.6 to 303.2 ± 15.6 meters, p = 0.0023) and Kansas City Cardiomyopathy Questionnaire (KCCQ) score (improvement of 20 ± 2.61 points, p < 0.0001). Significant reverse right ventricular remodeling was observed in terms of size and function. The overall major adverse event rate and all-cause mortality were both 7.1% at 1 year. CONCLUSION: Transcatheter tricuspid valve repair using the TriClip device was found to be safe and effective in patients with moderate or greater TR. The repair itself was durable at reducing TR at 1 year and was associated with a sustained and marked clinical benefit with low mortality after 1 year in a fragile population that was at high surgical risk. (TRILUMINATE Study With Abbott Transcatheter Clip Repair System in Patients With Moderate or Greater TR; NCT03227757).


Assuntos
Procedimentos Endovasculares/instrumentação , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Humanos , Masculino , Estudos Prospectivos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Remodelação Ventricular
14.
J Am Coll Cardiol ; 77(4): 345-356, 2021 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-33509390

RESUMO

BACKGROUND: Tricuspid regurgitation (TR) is a prevalent disease with limited treatment options. OBJECTIVES: This is the first 30-day report of the U.S. single-arm, multicenter, prospective CLASP TR early feasibility study of the PASCAL transcatheter valve repair system in the treatment of TR. METHODS: Patients with symptomatic TR despite optimal medical therapy, reviewed by the local heart team and central screening committee, were eligible for the study. Data were collected at baseline, discharge, and the 30-day follow-up and were reviewed by an independent clinical events committee and echocardiographic core laboratory. Feasibility endpoints included safety (composite major adverse event [MAE] rate), echocardiographic, clinical, and functional endpoints. RESULTS: Of the 34 patients enrolled in the study, the mean age was 76 years, 53% were women, the mean Society of Thoracic Surgeons score was 7.3%, 88% had atrial fibrillation/flutter, 97% had severe or greater TR, and 79% had New York Heart Association (NYHA) functional class III/IV symptoms. Twenty-nine patients (85%) received implants; at 30 days, 85% of them achieved a TR severity reduction of at least 1 grade, with 52% with moderate or less TR (p < 0.001). The MAE rate was 5.9%, and none of the patients experienced cardiovascular mortality, stroke, myocardial infarction, renal complication, or reintervention. Eighty-nine percent of the patients improved to NYHA functional class I/II (p < 0.001), the mean 6-min walk distance improved by 71 m (p < 0.001), and the mean Kansas City Cardiomyopathy Questionnaire score improved by 15 points (p < 0.001). CONCLUSIONS: In this early experience, the repair system performed as intended, with substantial TR reduction, favorable safety results with a low MAE rate, no mortality or reintervention, and significant improvements in functional status, exercise capacity, and quality of life. (Edwards CLASP TR EFS [CLASP TR EFS]; NCT03745313).


Assuntos
Anuloplastia da Valva Cardíaca/instrumentação , Procedimentos Endovasculares/instrumentação , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Idoso , Idoso de 80 Anos ou mais , Anuloplastia da Valva Cardíaca/estatística & dados numéricos , Ecocardiografia , Procedimentos Endovasculares/estatística & dados numéricos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Estudos Prospectivos , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico por imagem
15.
JACC Cardiovasc Interv ; 14(1): 41-50, 2021 01 11.
Artigo em Inglês | MEDLINE | ID: mdl-33413863

RESUMO

OBJECTIVES: The study reports for the first time the 30-day outcomes of the first U.S. study with the Cardioband tricuspid valve reconstruction system for the treatment of functional tricuspid regurgitation (TR). BACKGROUND: Increasing severity of TR is associated with progressively higher morbidity and mortality; however, treatment options for isolated significant disease are limited. METHODS: In this single-arm, multicenter, prospective Food and Drug Administration-approved early feasibility study (EFS), 30 patients with severe or greater symptomatic functional TR were enrolled who were deemed candidates for transcatheter tricuspid repair with the Cardioband tricuspid system by the local heart team and multidisciplinary screening committee. RESULTS: The mean patient age was 77 years, 80% were women, 97% had atrial fibrillation, 70% were in New York Heart Association functional class III to IV with mean left ventricular ejection fraction of 58%, and 27% had severe, 20% massive, and 53% torrential TR. Device success was 93% and all patients were alive at 30 days. Between baseline and 30 days, septolateral tricuspid annular diameter was reduced by 13% (p < 0.001), 85% of patients had ≥1 grade TR reduction and 44% had ≤moderate TR, 75% were in New York Heart Association functional class I to II (p < 0.001), and overall Kansas City Cardiomyopathy Questionnaire score improved by 16 points (p < 0.001). CONCLUSIONS: In patients with severe symptomatic functional TR, this is the first study in the United States with the Cardioband tricuspid system for direct transcatheter annular reduction. This early feasibility study demonstrates high procedural feasibility with no 30-day mortality. There is significant reduction of functional TR with clinically significant improvements in functional status and quality of life. (Edwards Cardioband Tricuspid Valve Reconstruction System Early Feasibility Study; NCT03382457).


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Idoso , Cateterismo Cardíaco , Estudos de Viabilidade , Feminino , Humanos , Masculino , Estudos Prospectivos , Qualidade de Vida , Índice de Gravidade de Doença , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Insuficiência da Valva Tricúspide/cirurgia , Função Ventricular Esquerda
16.
JACC Cardiovasc Interv ; 14(13): 1466-1477, 2021 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-34238557

RESUMO

OBJECTIVES: This study aimed to compare incidence and impact of measured prosthesis-patient mismatch (PPMM) versus predicted PPM (PPMP) after surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR). BACKGROUND: TAVR studies have used measured effective orifice area indexed (EOAi) to body surface area (BSA) to define PPM, but most SAVR series have used predicted EOAi. This difference may contribute to discrepancies in incidence and outcomes of PPM between series. METHODS: The study analyzed SAVR patients from the PARTNER (Placement of Aortic Transcatheter Valves) 2A trial and TAVR patients from the PARTNER 2 SAPIEN 3 Intermediate Risk registry. PPM was classified as moderate if EOAi ≤0.85 cm2/m2 (≤0.70 if obese: body mass index ≥30 kg/m2) and severe if EOAi ≤0.65 cm2/m2 (≤0.55 if obese). PPMM was determined by the core lab-measured EOAi on 30-day echocardiogram. PPMP was determined by 2 methods: 1) using normal EOA reference values previously reported for each valve model and size (PPMP1; n = 929 SAVR, 1,069 TAVR) indexed to BSA; and 2) using normal reference EOA predicted from aortic annulus size measured by computed tomography (PPMP2; n = 864 TAVR only) indexed to BSA. Primary endpoint was the composite of 5-year all-cause death and rehospitalization. RESULTS: The incidence of moderate and severe PPMP was much lower than PPMM in both SAVR (PPMP1: 28.4% and 1.2% vs. PPMM: 31.0% and 23.6%) and TAVR (PPMP1: 21.0% and 0.1% and PPMP2: 17.0% and 0% vs. PPMM: 27.9% and 5.7%). The incidence of severe PPMM and severe PPMP1 was lower in TAVR versus SAVR (P < 0.001). The presence of PPM by any method was associated with higher transprosthetic gradient. Severe PPMP1 was independently associated with events in SAVR after adjustment for sex and Society of Thoracic Surgeons score (hazard ratio: 3.18;95% CI: 1.69-5.96; P < 0.001), whereas no association was observed between PPM by any method and outcomes in TAVR. CONCLUSIONS: EOAi measured by echocardiography results in a higher incidence of PPM following SAVR or TAVR than PPM based on predicted EOAi. Severe PPMP is rare (<1.5%), but is associated with increased all-cause death and rehospitalization after SAVR, whereas it is absent following TAVR.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
17.
Circ Cardiovasc Imaging ; 14(11): e012809, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34743529

RESUMO

BACKGROUND: Low rest transaortic flow rate (FR) has been shown previously to predict mortality in low-gradient aortic stenosis. However limited prognostic data exists on stress FR during low-dose dobutamine stress echocardiography. We aimed to assess the value of stress FR for the detection of aortic valve stenosis (AS) severity and the prediction of mortality. METHODS: This is a multicenter cohort study of patients with reduced left ventricular ejection fraction and low-gradient aortic stenosis (aortic valve area <1 cm2 and mean gradient <40 mm Hg) who underwent low-dose dobutamine stress echocardiography to identify the AS severity and presence of flow reserve. The outcome assessed was all-cause mortality. RESULTS: Of the 287 patients (mean age, 75±10 years; males, 71%; left ventricular ejection fraction, 31±10%) over a mean follow-up of 24±30 months there were 127 (44.3%) deaths and 147 (51.2%) patients underwent aortic valve intervention. Higher stress FR was independently associated with reduced risk of mortality (hazard ratio, 0.97 [95% CI, 0.94-0.99]; P=0.01) after adjusting for age, chronic kidney disease, heart failure symptoms, aortic valve intervention, and rest left ventricular ejection fraction. The minimum cutoff for prediction of mortality was stress FR 210 mL/s. Following adjustment to the same important clinical and echocardiographic parameters, among the three criteria of AS severity during stress, ie, the guideline definition of aortic valve area <1cm2 and aortic valve mean gradient ≥40 mm Hg, or aortic valve mean gradient ≥40 mm Hg, or the novel definition of aortic valve area <1 cm2 at stress FR ≥210 mL/s, only the latter was independently associated with mortality (hazard ratio, 1.72 [95% CI, 1.05-2.82]; P=0.03). Furthermore aortic valve area <1cm2 at stress FR ≥210 mL/s was the only severe aortic stenosis criterion that was associated with improved outcome following aortic valve intervention (P<0.001). Guideline-defined stroke volume flow reserve did not predict mortality. CONCLUSIONS: Stress FR during low-dose dobutamine stress echocardiography was useful for the detection of both AS severity and flow reserve and was associated with improved prediction of outcome following aortic valve intervention.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo/fisiologia , Dobutamina/farmacologia , Ecocardiografia sob Estresse/métodos , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Idoso , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Cardiotônicos/farmacologia , Feminino , Seguimentos , Humanos , Masculino , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença
18.
EuroIntervention ; 17(10): 809-817, 2021 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-34031021

RESUMO

BACKGROUND: Severe tricuspid regurgitation (TR) has limited treatment options and is associated with high morbidity and mortality. AIMS: We evaluated the safety and effectiveness of the Cardioband tricuspid valve reconstruction system from the ongoing European single-arm, multicentre, prospective TriBAND post-market clinical follow-up study. METHODS: Eligible patients had chronic symptomatic functional TR despite diuretic therapy and were deemed candidates for transcatheter tricuspid repair by the local Heart Team. RESULTS: Sixty-one patients had ≥severe functional TR. At baseline, 85% of patients were in NYHA Class III-IV, 94% had ≥severe TR (core laboratory-assessed) with 6.8% EuroSCORE II and 53% LVEF. Device success was 96.7%. At discharge, 59% (p<0.001) of patients achieved ≤moderate TR and 78% had at least one grade TR reduction. At 30 days, all-cause mortality and composite MAE rates were 1.6% and 19.7%, respectively; septolateral annular diameter was reduced by 20%, where 69% of patients achieved ≤moderate TR and 85% of patients had at least one grade TR reduction (all p<0.001). Mid-RVEDD, RA volume, and IVC diameter decreased by 10% (p=0.005), 21% (p<0.001), and 11% (p=0.022), respectively; 74% were in NYHA Class I-II (p<0.001) with improvements in overall KCCQ score by 17 points (p<0.001). CONCLUSIONS: In the TriBAND study, the Cardioband tricuspid system demonstrated favourable outcomes at discharge and 30 days in a challenging patient population with symptomatic ≥severe functional TR. Results showed significant reductions in annular diameter and TR severity, accompanied by early evidence of right heart remodelling and improvements in functional status and quality of life.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Cateterismo Cardíaco , Seguimentos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Estudos Prospectivos , Qualidade de Vida , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
19.
J Am Coll Cardiol ; 76(15): 1737-1748, 2020 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-33032735

RESUMO

BACKGROUND: The prognostic value of aortic valve calcification (AVC) measured by using multidetector computed tomography imaging has been well validated in native aortic stenosis, and sex-specific thresholds have been proposed. However, few data are available regarding the impact of leaflet calcification on outcomes after biological aortic valve replacement (AVR). OBJECTIVES: The goal of this study was to analyze the association of quantitative bioprosthetic leaflet AVC with hemodynamic and clinical outcomes, as well as its possible interaction with sex. METHODS: From 2008 to 2010, a total of 204 patients were prospectively enrolled with a median of 7.0 years (interquartile range: 5.1 to 9.2 years) after biological surgical AVR. AVC measured by using the Agatston method was indexed to the cross-sectional area of aortic annulus measured by echocardiography to calculate the AVC density (AVCd). Presence of hemodynamic valve deterioration (HVD; increase in mean gradient [MG] ≥10 mm Hg and/or increase in transprosthetic regurgitation ≥1) was assessed by echocardiography in 137 patients at the 3-year follow-up. The primary clinical endpoint was mortality or aortic valve re-intervention. RESULTS: There was no significant sex-related difference in the relationship between bioprosthetic AVCd and the progression of MG. Baseline AVCd showed an independent association with HVD at 3 years. During follow-up, there were 134 (65.7%) deaths (n = 100) or valve re-interventions (n = 47). AVCd ≥58 AU/cm2 was independently associated with an increased risk of mortality or aortic valve re-intervention (adjusted hazard ratio: 2.23; 95% confidence interval: 1.44 to 3.35; p < 0.001). The AVCd threshold combined with an MG progression threshold of 10 mm Hg amplified the stratification of patients at risk (log-rank, p < 0.001). The addition of AVCd threshold into the prediction model including traditional risk factors improved outcome prediction (net classification improvement: 0.25, p = 0.04; likelihood ratio test, p < 0.001). CONCLUSIONS: Aortic bioprosthetic leaflet calcification is strongly and independently associated with HVD and the risk of death or aortic valve re-intervention. As opposed to native aortic stenosis, there is no sex-related differences in the relationship between AVCd and hemodynamic or clinical outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Calcinose/fisiopatologia , Próteses Valvulares Cardíacas/efeitos adversos , Hemodinâmica/fisiologia , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Calcinose/diagnóstico , Ecocardiografia Doppler , Feminino , Seguimentos , Humanos , Masculino , Tomografia Computadorizada Multidetectores/métodos , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo
20.
J Am Heart Assoc ; 9(24): e017870, 2020 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-33289422

RESUMO

Background No randomized comparison of early (ie, ≤3 months) aortic valve replacement (AVR) versus conservative management or of transcatheter AVR (TAVR) versus surgical AVR has been conducted in patients with low-flow, low-gradient (LFLG) aortic stenosis (AS). Methods and Results A total of 481 consecutive patients (75±10 years; 71% men) with LFLG AS (aortic valve area ≤0.6 cm2/m2 and mean gradient <40 mm Hg), 72% with classic LFLG and 28% with paradoxical LFLG, were prospectively recruited in the multicenter TOPAS (True or Pseudo Severe Aortic Stenosis) study. True-severe AS or pseudo-severe AS was adjudicated by flow-independent criteria. During follow-up (median [IQR] 36 [11-60] months), 220 patients died. Using inverse probability of treatment weighting to address the bias of nonrandom treatment assignment, early AVR (n=272) was associated with a major overall survival benefit (hazard ratio [HR], 0.34 [95% CI, 0.24-0.50]; P<0.001). This benefit was observed in patients with true-severe AS but also with pseudo-severe AS (HR, 0.38 [95% CI, 0.18-0.81]; P=0.01), and in classic (HR, 0.33 [95% CI, 0.22-0.49]; P<0.001) and paradoxical LFLG AS (HR, 0.42 [95% CI, 0.20-0.92]; P=0.03). Compared with conservative management in the conventional multivariate model, trans femoral TAVR was associated with the best survival (HR, 0.23 [95% CI, 0.12-0.43]; P<0.001), followed by surgical AVR (HR, 0.36 [95% CI, 0.23-0.56]; P<0.001) and alternative-access TAVR (HR, 0.51 [95% CI, 0.31-0.82]; P=0.007). In the inverse probability of treatment weighting model, trans femoral TAVR appeared to be superior to surgical AVR (HR [95% CI] 0.28 [0.11-0.72]; P=0.008) with regard to survival. Conclusions In this large prospective observational study of LFLG AS, early AVR appeared to confer a major survival benefit in both classic and paradoxical LFLG AS. This benefit seems to extend to the subgroup with pseudo-severe AS. Our findings suggest that TAVR using femoral access might be the best strategy in these patients. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT01835028.


Assuntos
Estenose da Valva Aórtica/terapia , Tratamento Conservador/métodos , Artéria Femoral/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Viés , Cateterismo Cardíaco/métodos , Estudos de Coortes , Tratamento Conservador/mortalidade , Feminino , Humanos , Masculino , Probabilidade , Modelos de Riscos Proporcionais , Estudos Prospectivos , Análise de Sobrevida , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA