Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Retina ; 42(7): 1311-1318, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35213528

RESUMO

PURPOSE: Soft drusen and subretinal drusenoid deposits (SDDs) characterize two pathways to advanced age-related macular degeneration (AMD), with distinct genetic risks, serum risks, and associated systemic diseases. METHODS: One hundred and twenty-six subjects with AMD were classified as SDD (with or without soft drusen) or non-SDD (drusen only) by retinal imaging, with serum risks, genetic testing, and histories of cardiovascular disease (CVD) and stroke. RESULTS: There were 62 subjects with SDD and 64 non-SDD subjects, of whom 51 had CVD or stroke. SDD correlated significantly with lower mean serum high-density lipoprotein (61 ± 18 vs. 69 ± 22 mg/dL, P = 0.038, t-test), CVD and stroke (34 of 51 SDD, P = 0.001, chi square), ARMS2 risk allele (P = 0.019, chi square), but not with CFH risk allele (P = 0.66). Non-SDD (drusen only) correlated/trended with APOE2 (P = 0.032) and CETP (P = 0.072) risk alleles (chi square). Multivariate independent risks for SDD were CVD and stroke (P = 0.008) and ARMS2 homozygous risk (P = 0.038). CONCLUSION: Subjects with subretinal drusenoid deposits and non-SDD subjects have distinct systemic associations and serum and genetic risks. Subretinal drusenoid deposits are associated with CVD and stroke, ARMS2 risk, and lower high-density lipoprotein; non-SDDs are associated with higher high-density lipoprotein, CFH risk, and two lipid risk genes. These and other distinct associations suggest that these lesions are markers for distinct diseases.


Assuntos
Doenças Cardiovasculares , Degeneração Macular , Drusas Retinianas , Acidente Vascular Cerebral , Humanos , Lipoproteínas HDL , Degeneração Macular/complicações , Drusas Retinianas/patologia , Acidente Vascular Cerebral/complicações , Tomografia de Coerência Óptica/métodos
2.
Ophthalmologica ; 240(1): 45-54, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29694963

RESUMO

OBJECTIVE: To evaluate PDE5/6 inhibition with sildenafil to reduce choroidal ischemia and treat age-related macular degeneration. METHODS: Sildenafil was prescribed to treat participants with macular degenerations or macular dystrophies measured by spectral-domain optical coherence tomography, color fundus photography, enhanced depth imaging, and best-corrected visual acuity. RESULTS: No change in calcified drusen was noted. Vitelliform-type soft drusen were not substantially changed. A participant with Best vitelliform macular dystrophy had a significant improvement in vision as well as in photoreceptor and ellipsoid layers. CONCLUSIONS: Our research supports sildenafil as a safe treatment for age-related and vitelliform macular degenerations. Thickened Bruch's membrane reduces the beneficial effect of perfusion increase, but all eyes appear to benefit from PDE6. Notably, maintenance or improvement in the photoreceptor layer may be the most significant result of sildenafil and is consistent with PDE6 inhibition. Thus, sil-denafil treatment of macular degeneration offers significant potential for vision retention and recovery.


Assuntos
Atrofia Geográfica/tratamento farmacológico , Inibidores da Fosfodiesterase 5/uso terapêutico , Citrato de Sildenafila/uso terapêutico , Distrofia Macular Viteliforme/tratamento farmacológico , Adulto , Idoso , Idoso de 80 Anos ou mais , Nucleotídeo Cíclico Fosfodiesterase do Tipo 6/antagonistas & inibidores , Feminino , Atrofia Geográfica/diagnóstico por imagem , Atrofia Geográfica/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Inibidores da Fosfodiesterase 5/administração & dosagem , Projetos Piloto , Drusas Retinianas/patologia , Citrato de Sildenafila/administração & dosagem , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia , Distrofia Macular Viteliforme/diagnóstico por imagem , Distrofia Macular Viteliforme/fisiopatologia
3.
Ultrason Imaging ; 39(5): 313-325, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28675987

RESUMO

Quantitative assessment of the material properties of ocular tissues can provide valuable information for investigating several ophthalmic diseases. Quantitative acoustic microscopy (QAM) offers a means of obtaining such information, but few QAM investigations have been conducted on human ocular tissue. We imaged the optic nerve (ON) and iridocorneal angle in 12-µm deparaffinized sections of the human eye using a custom-built acoustic microscope with a 250-MHz transducer (7-µm lateral resolution). The two-dimensional QAM maps of ultrasound attenuation (α), speed of sound ( c), acoustic impedance ( Z), bulk modulus ( K), and mass density (ρ) were generated. Scanned samples were then stained and imaged by light microscopy for comparison with QAM maps. The spatial resolution and contrast of scanning acoustic microscopy (SAM) maps were sufficient to resolve anatomic layers of the retina (Re); anatomic features in SAM maps corresponded to those seen by light microscopy. Significant variations of the acoustic parameters were found. For example, the sclera was 220 MPa stiffer than Re, choroid, and ON tissue. To the authors' knowledge, this is the first systematic study to assess c, Z, K, ρ, and α of human ocular tissue at the high ultrasound frequencies used in this study.


Assuntos
Olho/diagnóstico por imagem , Microscopia Acústica/métodos , Humanos
4.
J Acoust Soc Am ; 137(5): EL381-7, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25994737

RESUMO

Ex vivo assessment of microscale tissue biomechanical properties of the mammalian retina could offer insights into diseases such as keratoconus, and macular degeneration. A 250-MHz scanning acoustic microscope (7-µm resolution) has been constructed to derive two-dimensional quantitative maps of attenuation (α), speed of sound (c), acoustic impedance (Z), bulk modulus (B), and mass density ( ρ). The two-dimensional maps were compared to coregistered hematoxylin-and-eosin stained sections. This study is the first to quantitatively assess α, c, Z, B, and ρ of individual retinal layers of mammalian animals at high ultrasound frequencies. Significant differences in these parameters between the layers were demonstrated.


Assuntos
Microscopia Acústica , Retina/diagnóstico por imagem , Oxirredutases do Álcool/deficiência , Oxirredutases do Álcool/genética , Animais , Fenômenos Biomecânicos , Módulo de Elasticidade , Genótipo , Processamento de Imagem Assistida por Computador , Camundongos Knockout , Fenótipo , Retina/enzimologia
5.
J Ultrasound Med ; 33(8): 1417-26, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25063407

RESUMO

OBJECTIVES: To noninvasively measure changes in corneal biomechanical properties induced by ultraviolet-activated riboflavin cross-linking therapy using acoustic radiation force (ARF). METHODS: Cross-linking was performed on the right eyes of 6 rabbits, with the left eyes serving as controls. Acoustic radiation force was used to assess corneal stiffness before treatment and weekly for 4 weeks after treatment. Acoustic power levels were within US Food and Drug Administration guidelines for ophthalmic safety. Strain, determined from ARF-induced displacement of the front and back surfaces of the cornea, was fit to the Kelvin-Voigt model to determine the elastic modulus (E) and coefficient of viscosity (η). The stiffness factor, the ratio of E after treatment to E before treatment, was calculated for treated and control eyes. At the end of 4 weeks, ex vivo thermal shrinkage temperature analysis was performed for comparison with in vivo stiffness measurements. One-way analysis of variance and Student t tests were performed to test for differences in E, η, the stiffness factor, and corneal thickness. RESULTS: Biomechanical stiffening was immediately evident in cross-linking-treated corneas. At 4 weeks after treatment, treated corneas were 1.3 times stiffer and showed significant changes in E (P= .006) and η (P= .007), with no significant effect in controls. Corneal thickness increased immediately after treatment but did not differ significantly from the pretreatment value at 4 weeks. CONCLUSIONS: Our findings demonstrate a statistically significant increase in stiffness in cross-linking-treated rabbit corneas based on in vivo axial stress/strain measurements obtained using ARF. The capacity to noninvasively monitor corneal stiffness offers the potential for clinical monitoring of cross-linking therapy.


Assuntos
Córnea/diagnóstico por imagem , Reagentes de Ligações Cruzadas/farmacologia , Técnicas de Imagem por Elasticidade/métodos , Fármacos Fotossensibilizantes/farmacologia , Riboflavina/farmacologia , Terapia Ultravioleta/métodos , Análise de Variância , Animais , Fenômenos Biomecânicos/efeitos dos fármacos , Fenômenos Biomecânicos/fisiologia , Córnea/efeitos dos fármacos , Paquimetria Corneana/métodos , Elasticidade/efeitos dos fármacos , Seguimentos , Coelhos , Viscosidade/efeitos dos fármacos
6.
Exp Brain Res ; 209(3): 465-71, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21318347

RESUMO

It has been argued that both modality-specific and supramodal mechanisms dedicated to time perception underlie the estimation of interval durations. While it is generally assumed that early sensory areas are dedicated to modality-specific time estimation, we hypothesized that early sensory areas such as the primary visual cortex or the auditory cortex might be involved in time perception independently of the sensory modality of the input. To test this possibility, we examined whether disruption of the primary visual cortex or the auditory cortex would disrupt time estimation of auditory stimuli and visual stimuli using transcranial magnetic stimulation (TMS). We found that disruption of the auditory cortex impaired not only time estimation of auditory stimuli but also impaired that of visual stimuli to the same degree. This finding suggests a supramodal role of the auditory cortex in time perception. On the other hand, TMS over the primary visual cortex impaired performance only in visual time discrimination. These asymmetric contributions of the auditory and visual cortices in time perception may be explained by a superiority of the auditory cortex in temporal processing. Here, we propose that time is primarily encoded in the auditory system and that visual inputs are automatically encoded into an auditory representation in time discrimination tasks.


Assuntos
Córtex Auditivo/fisiologia , Discriminação Psicológica/fisiologia , Percepção do Tempo/fisiologia , Estimulação Acústica/métodos , Adulto , Análise de Variância , Feminino , Humanos , Masculino , Estimulação Luminosa/métodos , Tempo de Reação/fisiologia , Limiar Sensorial/fisiologia , Estimulação Magnética Transcraniana/métodos , Córtex Visual/fisiologia , Adulto Jovem
7.
J Cataract Refract Surg ; 34(11): 1906-12, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19006737

RESUMO

PURPOSE: To compare central corneal thickness (CCT) measurements by the Orbscan II device, contact ultrasound (US) pachymetry, and the noncontact Artemis 2 scanning US system. SETTING: Department of Ophthalmology, Weill Cornell Medical College, New York, New York, USA. METHODS: The CCT in 40 eyes (20 normal subjects) was measured by the Orbscan II followed by contact US pachymetry and then the Artemis 2. Results were compared using analysis of variance (ANOVA), paired t tests, and Bland-Altman plots. RESULTS: There was a significant difference in CCT measurements between the 3 modes (F = 32.84, P = .0001, 1-way ANOVA). Artemis 2 and US pachymetry measurements were highly correlated (r2 = 0.963, P < .0001), although Artemis 2 values were a mean of 11.2 microm +/- 6.6 (SD) thinner than pachymetry values. Artemis 2 and Orbscan II measurements were less well correlated (r2 = 0.851, P < .001); Orbscan II values were a mean of 7.5 +/- 15.7 microm thinner than Artemis 2 values. Orbscan II values showed a trend toward increasing underestimation of CCT in thinner corneas. CONCLUSIONS: Ultrasound pachymetry and Artemis 2 CCT measurements were highly correlated; the 11 microm mean difference in measurements may be attributed to decentration, oblique incidence of the probe to the cornea, or possibly the effect of topical anesthesia with contact pachymetry. Although the mean difference between Orbscan II and Artemis 2 values was 7.5 microm, Orbscan values were less correlated than Artemis 2 values with contact US pachymetry and were prone to underestimation of the CCT in thinner corneas.


Assuntos
Córnea/anatomia & histologia , Técnicas de Diagnóstico Oftalmológico , Adulto , Pesos e Medidas Corporais , Córnea/diagnóstico por imagem , Topografia da Córnea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Ultrassonografia
8.
J Biophotonics ; 11(6): e201700278, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29314709

RESUMO

A frequency-domain, non-contact approach to photoacoustic microscopy (PAM) that employs amplitude-modulated (0.1-1 MHz) laser for excitation (638-nm pump) in conjunction with a 2-wave mixing interferometer (532-nm probe) for non-contact detection of photoacoustic waves at the specimen surface is presented. A lock-in amplifier is employed to detect the photoacoustic signal. Illustrative images of tissue-mimicking phantoms, red-blood cells and retinal vasculature are presented. Single-frequency modulation of the pump beam directly provides an image that is equivalent to the 2-dimensional projection of the image volume. Targets located superficially produce phase modulations in the surface-reflected probe beam due to surface vibrations as well as direct intensity modulation in the backscattered probe light due to local changes in pressure and/or temperature. In comparison, the observed modulations in the probe beam due to targets located deeper in the specimen, for example, beyond the ballistic photon regime, predominantly consist of phase modulation.


Assuntos
Interferometria/instrumentação , Microscopia/instrumentação , Técnicas Fotoacústicas/instrumentação , Eritrócitos/citologia , Humanos , Microvasos/diagnóstico por imagem , Imagens de Fantasmas , Retina/fisiologia
9.
Transl Vis Sci Technol ; 7(5): 5, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30197837

RESUMO

PURPOSE: The choroid is a vascular network providing the bulk of the oxygen and nutrient supply to the retina and may play a pivotal role in retinal disease pathogenesis. While optical coherence tomography angiography provides an en face depiction of the choroidal vasculature, it does not reveal flow dynamics. In this report, we describe the use of plane-wave ultrasound to image and characterize choroidal blood flow. METHODS: We scanned both eyes of 12 healthy subjects in a horizontal plane superior to the optic nerve head using an 18-MHz linear array. Plane-wave data were acquired over 10 transmission angles that were coherently compounded to produce 1000 images/sec for 3 seconds. These data were processed to produce a time series of power Doppler images and spectrograms depicting choroidal flow velocity. Analysis of variance was used to characterize peak systolic, and end diastolic velocities and resistive index, and their variability between scans, eyes, and subjects. RESULTS: Power Doppler images showed distinct arterioles within a more diffuse background. Choroidal flow was moderately pulsatile, with peak systolic velocity averaging approximately 10 mm/sec and resistive index of 0.55. There was no significant difference between left and right eyes, but significant variation among subjects. CONCLUSIONS: Plane-wave ultrasound visualized individual arterioles and allowed measurement of flow over the cardiac cycle. Characterization of choroidal flow dynamics offers a novel means for assessment of the choroid's role in ocular disease. TRANSLATIONAL RELEVANCE: Characterization of choroidal flow dynamics offers a novel means for assessment of the choroid's role in ocular disease.

10.
Transl Vis Sci Technol ; 7(2): 21, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29670830

RESUMO

PURPOSE: Mapping of epithelial thickness (ET) is useful for detection of keratoconus, a disease characterized by corneal thinning and bulging in which epithelial thinning occurs over the apex. In prior clinical studies, optical coherence tomography (OCT) measurements of ET were systematically thinner than those obtained by 40-MHz high-frequency ultrasound (HFU) where a constant speed of sound (c) of 1636 m/s was used for all corneal layers. The purpose of this work was to study the acoustic properties, that is, c, acoustic impedance (Z), and attenuation (α) of the corneal epithelium and stroma independently using a scanning acoustic microscope (SAM) to investigate the discrepancy between OCT and HFU estimates of ET. METHODS: Twelve unfixed pig corneas were snap-frozen and 6-µm sections were scanned using a custom-built SAM with an F-1.08, 500-MHz transducer and a 264-MHz bandwidth. Two-dimensional maps of c, Z, and α with a spatial resolution of 4 µm were derived. RESULTS: SAM showed that the value of c in the epithelium (i.e., 1548 ± 18 m/s) is substantially lower than the value of c in the stroma (i.e., 1686 ± 33 m/s). CONCLUSION: SAM results demonstrated that the assumption of a constant value of c for all corneal layers is incorrect and explains the prior discrepancy between OCT and HFU ET determinations. TRANSLATIONAL RELEVANCE: The findings of this study have important implications for HFU-based ET measurements and will improve future keratoconus diagnosis by providing more-accurate ET estimates.

11.
IEEE Trans Biomed Eng ; 64(3): 715-724, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27249824

RESUMO

OBJECTIVE: This paper describes development of a novel 500-MHz scanning acoustic microscope (SAM) for assessing the mechanical properties of ocular tissues at fine resolution. The mechanical properties of some ocular tissues, such as lamina cribrosa (LC) in the optic nerve head, are believed to play a pivotal role in eye pathogenesis. METHODS: A novel etching technology was used to fabricate silicon-based lens for a 500-MHz transducer. The transducer was tested in a custom-designed scanning system on human eyes. Two-dimensional (2-D) maps of bulk modulus (K) and mass density (ρ) were derived using improved versions of current state-of-the-art signal processing approaches. RESULTS: The transducer employed a lens radius of 125 µm and had a center frequency of 479 MHz with a -6-dB bandwidth of 264 MHz and a lateral resolution of 4 µm. The LC, Bruch's membrane (BM) at the interface of the retina and choroid, and Bowman's layer (BL) at the interface of the corneal epithelium and stroma, were successfully imaged and resolved. Analysis of the 2-D parameter maps revealed average values of LC, BM, and BL with KLC = 2.81 ±0.17; GPa, KBM = 2.89 ±0.18; GPa, KBL = 2.6 ±0.09 ; GPa, ρ LC = 0.96 ±0.03 g/cm3; ρ BM = 0.97 ±0.04 g/cm3; ρ BL = 0.98 ±0.04 g/cm3. SIGNIFICANCE: This novel SAM was shown to be capable of measuring mechanical properties of soft biological tissues at microscopic resolution; it is currently the only system that allows simultaneous measurement of K, ρ, and attenuation in large lateral scales (field area >9 mm2) and at fine resolutions.


Assuntos
Aumento da Imagem/instrumentação , Lentes , Microscopia Acústica/instrumentação , Oftalmoscópios , Retina/citologia , Retina/diagnóstico por imagem , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Transdutores
12.
J Cataract Refract Surg ; 42(1): 95-101, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26948783

RESUMO

PURPOSE: To compare corneal thickness and epithelial thickness measurements in maps obtained using the RTVue spectral domain optical coherence tomography (SD-OCT) system and the Artemis 2 immersion arc-scanning very-high-frequency ultrasound (VHF-US) system. SETTING: Department of Ophthalmology, Columbia University Medical Center, New York, New York, USA. DESIGN: Comparative study. METHODS: Eyes of normal volunteers were scanned with the SD-OCT system followed by the VHF-US system and then again by the SD-OCT system. On each map, the minimum corneal thickness and mean values of corneal thickness and epithelial thickness in the 3.0 mm radius zone and in 0.5 mm wide concentric annuli of up to a 3.0 mm radius around the corneal vertex were determined. RESULTS: Both eyes of 12 normal volunteers were scanned. The corneal thickness values from both devices were highly correlated (R > 0.96); in the 3.0 mm radius zone, they were not statistically significantly different. There was no statistically significant change in epithelial thickness or corneal thickness in SD-OCT measurements taken before versus after immersion US. Although highly correlated (R > 0.76), the SD-OCT epithelial thickness values were systematically thinner (1.7 ± 2.1 µm) than the VHF-US measurements in the 3.0 mm radius zone (P < .01). CONCLUSIONS: The corneal thickness measurements in the 3.0 mm radius zone in normal eyes were equivalent between the 2 systems. Although correlated, the VHF-US epithelial thickness measurements were systemically thicker than the SD-OCT values. FINANCIAL DISCLOSURES: Drs. Silverman and Reinstein have a commercial interest in Arcscan, Inc. Dr. Reinstein is a consultant to Carl Zeiss Meditec. None of the other authors has a financial or proprietary interest in any material or method presented.


Assuntos
Biometria/instrumentação , Córnea/anatomia & histologia , Paquimetria Corneana , Epitélio Corneano/anatomia & histologia , Ondas de Choque de Alta Energia , Tomografia de Coerência Óptica/instrumentação , Ultrassom/instrumentação , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino
14.
Ultrasound Med Biol ; 29(7): 951-9, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12878240

RESUMO

Specific extracellular matrix patterns in uveal melanoma are associated with metastatic risk. The laminin-rich composition and dimensions (on the order of a wavelength or less) of these structures suggest that acoustic backscatter might be affected by their presence. In this study, 10-MHz radiofrequency (RF) ultrasound (US) data were acquired before surgical removal of 117 eyes with uveal malignant melanoma. Histologic sections were evaluated for the presence of matrix patterns and acoustic backscatter was characterized using calibrated spectrum analysis. Statistical correlations between acoustic and histologic patterns were determined and linear discriminant analysis (LDA) and radial basis networks (RBN) were used to develop classification models for histologically based risk groups. Statistically significant correlations were found between acoustic parameters and the presence of histologic matrix-rich patterns. Retrospective classification accuracies of 74.4% and 78.6% were obtained with LDA and RBN, respectively. Leave-one-out analyses indicated estimated predictive accuracies of 71.8% and 75.0% for LDA and RBN, respectively.


Assuntos
Matriz Extracelular/ultraestrutura , Melanoma/ultraestrutura , Processamento de Sinais Assistido por Computador , Neoplasias Uveais/ultraestrutura , Humanos , Melanoma/secundário , Prognóstico , Curva ROC , Sensibilidade e Especificidade , Neoplasias Uveais/secundário
15.
J Pediatr Ophthalmol Strabismus ; 41(6): 345-50, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15609519

RESUMO

PURPOSE: Screening for detection of retinopathy of prematurity (ROP) currently is limited to indirect ophthalmoscopy, which requires considerable examiner skill and experience. We investigated whether conventional 10 MHz B-scan ultrasonography could document the clinical stages of ROP as accurately as indirect ophthalmoscopy. METHODS: Thirty-four eyes of 18 neonates were examined by masked, independent observers with indirect ophthalmoscopy and digitally recorded 10-MHz B-scan ultrasonography. After pupil dilation and lid speculum placement, the retinologist recorded the stage of retinopathy with a retinal drawing. The ultrasonographer, without use of papillary mydriatics or lid speculum, determined the presence or absence of a ridge or tractional elements, if present on the ridge. RESULTS: Ultrasound grade correlated with clinical grade (R = .79, P < .001). However, nine eyes were overdiagnosed by one stage, and one eye, in which a peripheral detachment was mistaken for an artifact, was underdiagnosed. CONCLUSIONS: Ten-megahertz ultrasonography offers the potential of imaging and detecting the clinical stages of ROP; the use of higher ultrasound frequencies, now becoming commercially available, is likely to enhance diagnostic accuracy. Care must be taken to distinguish between artifact and true anatomical structures in noncontact ultrasound examinations. Neonates with suspected ROP could be screened with B-scan ultrasonography by neonatal personnel without pupillary dilatation or lid speculum, thus eliminating potential morbidity, and clinically significant cases of ROP then could be referred to the retinologist.


Assuntos
Oftalmoscopia/métodos , Retina/diagnóstico por imagem , Retinopatia da Prematuridade/diagnóstico por imagem , Fundo de Olho , Idade Gestacional , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Retina/patologia , Retinopatia da Prematuridade/classificação , Retinopatia da Prematuridade/terapia , Ultrassonografia
16.
Invest Ophthalmol Vis Sci ; 54(1): 103-9, 2013 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-23211817

RESUMO

PURPOSE: While visualization of the retina and choroid has made great progress, functional imaging techniques have been lacking. Our aim was to utilize acoustic radiation force impulse (ARFI) response to probe functional properties of these tissues. METHODS: A single element 18-MHz ultrasound transducer was focused upon the retina of the rabbit eye. The procedure was performed with the eye proptosed and with the eye seated normally in the orbit. The transducer was excited to emit ARFI over a 10-ms period with a 25% duty cycle. Phase resolved pulse/echo data were acquired before, during, and following ARFI. RESULTS: In the proptosed eye, ARFI exposure produced tissue displacements ranging from 0 to 10 µm, and an immediate increase in choroidal echo amplitude to over 6 dB, decaying to baseline after about 1 second. In the normally seated eye, ultrasound phase shifts consistent with flow were observed in the choroid, but enhanced backscatter following ARFI rarely occurred. ARFI-induced displacements of about 10 µm were observed at the choroidal margins. Larger displacements occurred within the choroid and in orbital tissues. CONCLUSIONS: We hypothesize that elevated intraocular pressure occurring during proptosis induced choroidal ischemia and that acoustic radiation force produced a transient local decompression and reperfusion. With the eye normally seated, choroidal flow was observed and little alteration in backscatter resulted from exposure. Clinical application of this technique may provide new insights into diseases characterized by altered choroidal hemodynamics, including maculopathies, diabetic retinopathy, and glaucoma.


Assuntos
Corioide/diagnóstico por imagem , Técnicas de Imagem por Elasticidade , Animais , Velocidade do Fluxo Sanguíneo/fisiologia , Corioide/irrigação sanguínea , Elasticidade/fisiologia , Exoftalmia/fisiopatologia , Pressão Intraocular/fisiologia , Isquemia/diagnóstico por imagem , Isquemia/fisiopatologia , Artéria Oftálmica/fisiologia , Fluxo Pulsátil , Coelhos , Tonometria Ocular , Transdutores
17.
Acta Ophthalmol ; 91(2): 183-8, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22974308

RESUMO

PURPOSE: To demonstrate anatomic and physiologic changes in the human choroid following systemic sildenafil citrate (Viagra®) using enhanced depth imaging spectral domain-optical coherence tomography (EDI-OCT) and swept-scan high-frequency digital ultrasound. METHODS: Seven healthy male subjects (mean age 32.7 years) were evaluated at baseline and 2 hr after ingesting 50 mg of sildenafil. Swept-scan high-frequency digital ultrasound and EDI-OCT were utilized to measure choroidal perfusion and thickness, respectively. Results were read by masked observers. The Wilcoxon signed-rank test and t-test were used to analyse differences in choroidal flow and thickness at baseline and 2 hr after ingestion of sildenafil. RESULTS: Two hours following sildenafil, increased choroidal perfusion was observed in 11 of 12 eyes measured by swept-scan high-frequency digital ultrasound. The mean increase was 3.46 (±2.00) times baseline with a range of 0.47-7.80 times baseline (p = 0.004). Increased choroidal thickness was observed in 12 of 12 eyes measured with EDI-OCT. The average choroidal thickness increased by 11.6% temporal to the fovea, 9.3% nasal to the fovea and 10.7% underneath the fovea (p < 0.001 for all values). CONCLUSIONS: Choroidal perfusion and thickness both increase in response to systemic sildenafil. These changes could secondarily affect retinal function, explain previously reported clinical symptoms and potentially be a useful adjunct for treatment of ocular diseases that would benefit from increased choroidal blood flow.


Assuntos
Corioide/anatomia & histologia , Corioide/irrigação sanguínea , Piperazinas/administração & dosagem , Sulfonas/administração & dosagem , Vasodilatadores/administração & dosagem , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Humanos , Masculino , Purinas/administração & dosagem , Fluxo Sanguíneo Regional/fisiologia , Citrato de Sildenafila , Tomografia de Coerência Óptica
18.
Br J Ophthalmol ; 97(8): 1020-3, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23740965

RESUMO

AIM: Our aim is to use ultrasound to non-invasively detect differences in choroidal microarchitecture possibly related to ischaemia among normal eyes and those with wet and dry age-related macular degeneration (AMD). DESIGN: Prospective case series of subjects with dry AMD, wet AMD and age-matched controls. METHODS: Digitised 20 MHz B-scan radiofrequency ultrasound data of the region of the macula were segmented to extract the signal from the retina and choroid. This signal was processed by a wavelet transform, and statistical modelling was applied to the wavelet coefficients to examine differences among dry, wet and non-AMD eyes. Receiver operating characteristic (ROC) analysis was used to evaluate a multivariate classifier. RESULTS: In the 69 eyes of 52 patients, 18 did not have AMD, 23 had dry AMD and 28 had wet AMD. Multivariate models showed statistically significant differences between groups. Multiclass ROC analysis of the best model showed an excellent volume-under-curve of 0.892±0.17. The classifier is consistent with ischaemia in dry AMD. CONCLUSIONS: Wavelet augmented ultrasound is sensitive to the organisational elements of choroidal microarchitecture relating to scatter and fluid tissue boundaries such as seen in ischaemia and inflammation, allowing statistically significant differentiation of dry, wet and non-AMD eyes. This study further supports the association of ischaemia with dry AMD and provides a rationale for treating dry AMD with pharmacological agents to increase choroidal perfusion. ClinicalTrials.gov registration: NCT00277784.


Assuntos
Corioide/irrigação sanguínea , Atrofia Geográfica/diagnóstico por imagem , Isquemia/diagnóstico por imagem , Degeneração Macular Exsudativa/diagnóstico por imagem , Corantes , Angiofluoresceinografia , Atrofia Geográfica/classificação , Humanos , Verde de Indocianina , Estudos Prospectivos , Curva ROC , Tomografia de Coerência Óptica , Ultrassonografia , Degeneração Macular Exsudativa/classificação
19.
Artigo em Inglês | MEDLINE | ID: mdl-21902166

RESUMO

The vitreous body is nearly transparent both optically and ultrasonically. Conventional 10- to 12-MHz diagnostic ultrasound can detect vitreous inhomogeneities at high gain settings, but has limited resolution and sensitivity, especially outside the fixed focal zone near the retina. To improve visualization of faint intravitreal fluid/gel interfaces, the authors fabricated a spherically curved 20-MHz five-element annular array ultrasound transducer, implemented a synthetic-focusing algorithm to extend the depth-of-field, and used a pulse-encoding strategy to increase sensitivity. The authors evaluated a human subject with a recent posterior vitreous detachment and compared the annular array with conventional 10-MHz ultrasound and spectral-domain optical coherence tomography. With synthetic focusing and chirp pulse-encoding, the array allowed visualization of the formed and fluid components of the vitreous with improved sensitivity and resolution compared with the conventional B-scan. Although optical coherence tomography allowed assessment of the posterior vitreoretinal interface, the ultrasound array allowed evaluation of the entire vitreous body.


Assuntos
Técnicas de Diagnóstico Oftalmológico/instrumentação , Ultrassonografia/instrumentação , Corpo Vítreo/diagnóstico por imagem , Descolamento do Vítreo/diagnóstico por imagem , Algoritmos , Desenho de Equipamento , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia de Coerência Óptica , Transdutores
20.
Ultrasound Med Biol ; 36(5): 733-42, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20420969

RESUMO

Optical coherence tomography (OCT) and ultrasound (US) are methods widely used for diagnostic imaging of the eye. These techniques detect discontinuities in optical refractive index and acoustic impedance, respectively. Because these both relate to variations in tissue density or composition, OCT and US images share a qualitatively similar appearance. In photoacoustic imaging (PAI), short light pulses are directed at tissues, pressure is generated due to a rapid energy deposition in the tissue volume and thermoelastic expansion results in generation of broadband US. PAI thus depicts optical absorption, which is independent of the tissue characteristics imaged by OCT or US. Our aim was to demonstrate the application of PAI in ocular tissues and to do so with lateral resolution comparable to OCT. We developed two PAI assemblies, both of which used single-element US transducers and lasers sharing a common focus. The first assembly had optical and 35-MHz US axes offset by a 30 degrees angle. The second assembly consisted of a 20-MHz ring transducer with a coaxial optics. The laser emitted 5-ns pulses at either 532 nm or 1064 nm, with spot sizes at the focus of 35 microm for the angled probe and 20 microm for the coaxial probe. We compared lateral resolution by scanning 12.5 microm diameter wire targets with pulse/echo US and PAI at each wavelength. We then imaged the anterior segment in whole ex vivo pig eyes and the choroid and ciliary body region in sectioned eyes. PAI data obtained at 1064 nm in the near infrared had higher penetration but reduced signal amplitude compared to that obtained using the 532 nm green wavelength. Images were obtained of the iris, choroid and ciliary processes. The zonules and anterior cornea and lens surfaces were seen at 532 nm. Because the laser spot size was significantly smaller than the US beamwidth at the focus, PAI images had superior resolution than those obtained using conventional US.


Assuntos
Técnicas de Imagem por Elasticidade/instrumentação , Olho/diagnóstico por imagem , Oftalmoscópios , Transdutores , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Técnicas In Vitro , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA