1.
Shokuhin Eiseigaku Zasshi ; 63(2): 51-61, 2022.
Artigo em Japonês | MEDLINE | ID: mdl-35650029

RESUMO

Migration test of food utensils, containers, and packaging is an important test method for confirming the safety and their compliance to the standards. However, there is little report on inter-laboratory study which was performed to evaluate the entire migration test, including migration operations and quantification. An interlaboratory study was performed participating 22 laboratories using 8 types of model synthetic resin samples containing 10 substances with a wide range of Log Pow values to evaluate the accuracy of the entire migration test. As a result, most of HorRat (r) values met the target criteria (0.3

Assuntos
Contaminação de Alimentos , Plásticos , Contaminação de Alimentos/análise , Embalagem de Alimentos , Laboratórios
2.
Shokuhin Eiseigaku Zasshi ; 59(1): 55-63, 2018.
Artigo em Japonês | MEDLINE | ID: mdl-29743469

RESUMO

An interlaboratory study was performed to evaluate the equivalence between an official method and a modified method of evaporation residue test using three food-simulating solvents (water, 4% acetic acid and 20% ethanol), based on the Japanese Food Sanitation Law for food contact products. Twenty-three laboratories participated, and tested the evaporation residues of nine test solutions as blind duplicates. For evaporation, a water bath was used in the official method, and a hot plate in the modified method. In most laboratories, the test solutions were heated until just prior to evaporation to dryness, and then allowed to dry under residual heat. Statistical analysis revealed that there was no significant difference between the two methods, regardless of the heating equipment used. Accordingly, the modified method provides performance equal to the official method, and is available as an alternative method.


Assuntos
Utensílios de Alimentação e Culinária , Contaminação de Alimentos/análise , Embalagem de Alimentos , Ácido Acético , Etanol , Contaminação de Alimentos/prevenção & controle , Japão , Laboratórios , Soluções , Solventes , Volatilização , Água
3.
Shokuhin Eiseigaku Zasshi ; 59(1): 64-71, 2018.
Artigo em Japonês | MEDLINE | ID: mdl-29743470

RESUMO

An interlaboratory study was performed to evaluate the equivalence between an official method and a modified method of evaporation residue test using heptane as a food-simulating solvent for oily or fatty foods, based on the Japanese Food Sanitation Law for food contact products. Twenty-three laboratories participated, and tested the evaporation residues of nine test solutions as blind duplicates. In the official method, heating for evaporation was done with a water bath. In the modified method, a hot plate was used for evaporation, and/or a vacuum concentration procedure was skipped. In most laboratories, the test solutions were heated until just prior to dryness, and then allowed to dry under residual heat. Statistical analysis revealed that there was no significant difference between the two methods. Accordingly, the modified method provides performance equal to the official method, and is available as an alternative method. Furthermore, an interlaboratory study was performed to evaluate and compare two leaching solutions (95% ethanol and isooctane) used as food-simulating solvents for oily or fatty foods in the EU. The results demonstrated that there was no significant difference between heptane and these two leaching solutions.


Assuntos
Utensílios de Alimentação e Culinária , Contaminação de Alimentos/análise , Embalagem de Alimentos , Etanol , Álcoois Graxos , Contaminação de Alimentos/prevenção & controle , Japão , Laboratórios , Legislação sobre Alimentos , Octanos , Soluções , Volatilização
4.
Shokuhin Eiseigaku Zasshi ; 57(6): 222-229, 2016.
Artigo em Japonês | MEDLINE | ID: mdl-28025457

RESUMO

The Japanese Food Sanitation Law sets a limit on the migration level of caprolactam for food-contacting nylon products. Here, we carried out an interlaboratory study in twenty laboratories to evaluate the performance of the official GC-FID test method and a GC-MS method as an alternative test method to the official method. Each laboratory quantified caprolactam in three test solutions in 20% ethanol as blind duplicates using GC-FID or GC-MS. The official method (GC-FID with absolute calibration) gave trueness, repeatability (RSDr) and reproducibility (RSDr) values of 96-97%, 3.3-5.4% and 4.0-6.7%, respectively. These values met the target criteria (trueness: 80-110%, RSDr: 10%, RSDr: 25%). The performance of the method was further improved by the introduction of heptalactam as an internal standard. As for GC-MS method, some values of the RSDr exceeded 10% when absolute calibration was used. However, when an internal standard was introduced, the trueness, RSDr and RSDr of GC-MS method were all acceptable at 94-96%, 2.0-4.4% and 7.0-9.4%, respectively. Therefore, GC-MS with an internal standard is available as an alternative test method to the official method.


Assuntos
Caprolactama/análise , Utensílios de Alimentação e Culinária , Análise de Alimentos/métodos , Embalagem de Alimentos , Laboratórios , Nylons/química , Cromatografia Gasosa , Inocuidade dos Alimentos , Cromatografia Gasosa-Espectrometria de Massas , Legislação sobre Alimentos/normas , Espectrometria de Fluorescência
5.
Shokuhin Eiseigaku Zasshi ; 57(5): 169-178, 2016.
Artigo em Japonês | MEDLINE | ID: mdl-27784869

RESUMO

Using polystyrene, acrylonitrile-styrene resin and acrylonitrile-butadiene-styrene resin pellets as samples, an interlaboratory study was performed to evaluate the volatiles test method, based on the specifications described in the Japanese Food Sanitation Law for food-contacting polystyrene products. The study was conducted with the participation of twenty-one laboratories. Each laboratory quantified the contents of styrene, toluene, ethylbenzene, isopropylbenzene and propylbenzene in three test pellets using GC-FID, GC-MS or headspace-GC-FID. Statistical analysis revealed that the repeatability (RSDr) and reproducibility (RSDr) were 1.0-2.6 and 2.5-5.5% for the GC-FID method. The values of the performance parameters fulfilled the requirements (RSDr: 10%, RSDr: 25%), and the performance is sufficient for specifications testing. The RSDr and RSDr of results obtained using the GC-MS and HS-GC methods were 1.4-7.8 and 4.9-13%(GC-MS), and 2.0-2.6 and 3.3-6.9%(HS-GC-FID), respectively. The quantified levels were similar to those obtained with GC-FID. The study suggests that the GC-MS and HS-GC methods can be employed as alternative methods to the GC-FID method.


Assuntos
Resinas Acrílicas/química , Butadienos/química , Utensílios de Alimentação e Culinária , Embalagem de Alimentos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Poliestirenos/química , Compostos Orgânicos Voláteis/análise , Derivados de Benzeno/análise , Japão , Laboratórios , Legislação sobre Alimentos , Reprodutibilidade dos Testes , Espectrometria de Fluorescência/métodos , Estireno/análise , Tolueno/análise
6.
Shokuhin Eiseigaku Zasshi ; 56(3): 123-31, 2015.
Artigo em Japonês | MEDLINE | ID: mdl-26156169

RESUMO

Using six kinds of zinc solution in water and 4% acetic acid as samples, an interlaboratory study was performed to evaluate a zinc (Zn) test method for food-contact rubber products, based on the Japanese Food Sanitation Law. Eighteen laboratories participated, and quantified Zn in six test solutions as blind duplicates using flame atomic absorption spectrometry, induced coupled plasma-optical emission spectrometry or induced coupled plasma-mass spectrometry. Statistical analysis revealed that the trueness, repeatability (RSDr) and reproducibility (RSDr) were 97-103%, 0.7-4.9% and 1.7-8.9% by all measuring methods. The values of the performance parameter fulfilled the target value (trueness: 80-110%, RSDr: 10%, RSDr: 25%). The performance of these methods is sufficient for testing the adherence of samples to the specifications.


Assuntos
Utensílios de Alimentação e Culinária , Análise de Alimentos/métodos , Contaminação de Alimentos/análise , Embalagem de Alimentos , Análise de Perigos e Pontos Críticos de Controle/métodos , Espectrometria de Massas/métodos , Borracha/química , Espectrofotometria Atômica/métodos , Zinco/análise , Estudos de Viabilidade , Inocuidade dos Alimentos , Reprodutibilidade dos Testes , Soluções
7.
Shokuhin Eiseigaku Zasshi ; 56(2): 57-67, 2015.
Artigo em Japonês | MEDLINE | ID: mdl-25925077

RESUMO

An interlaboratory study was performed to evaluate a migration test method of antimony (Sb) and germanium (Ge), based on the Japanese Food Sanitation Law for food- contact polyethylene terephthalate. Eighteen laboratories participated, and quantified Sb and Ge in three test solutions as blind duplicates using graphite furnace atomic absorption spectrometry (GF-AAS), inductively coupled plasma-optical emission spectrometry (ICP-OES) or induced coupled plasma-mass spectrometry (ICP-MS). Statistical analysis revealed that the trueness, repeatability and reproducibility were 98-107%, 1.7-7.5% and 2.0-18.8% by using GF-AAS and ICP-OES. The performance of these methods is sufficient for testing the specifications. The performance parameters of ICP-MS were 99-106%, 0.7-2.2% and 2.2-10.5%, respectively. ICP-MS is available as an alternative measuring method. However, in some laboratories, the quantitative values of Sb were higher than the addition levels. We found that Sb in working solutions is absorbed on glass vessels. Careful control of concentration in working solutions is required for Sb analysis.


Assuntos
Antimônio/análise , Utensílios de Alimentação e Culinária , Embalagem de Alimentos , Germânio/análise , Análise de Perigos e Pontos Críticos de Controle/métodos , Laboratórios/normas , Polietilenotereftalatos/química , Inocuidade dos Alimentos , Japão , Legislação sobre Alimentos , Espectrometria de Massas , Reprodutibilidade dos Testes , Soluções , Espectrofotometria Atômica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA