Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 26(Pt 5): 1554-1557, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31490143

RESUMO

The manufacturing steps and first tests of a refractive lens made of polycrystalline diamond are described. A fabrication process based on electron-beam lithography and deep reactive ion etching is introduced. Experimental tests on beamline ID13 at the ESRF have been performed. A spot size of 360 nm (FWHM) at an energy E = 24.3 keV is observed.

2.
J Synchrotron Radiat ; 24(Pt 2): 413-421, 2017 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28244434

RESUMO

Point focusing measurements using pairs of directly bonded crossed multilayer Laue lenses (MLLs) are reported. Several flat and wedged MLLs have been fabricated out of a single deposition and assembled to realise point focusing devices. The wedged lenses have been manufactured by adding a stress layer onto flat lenses. Subsequent bending of the structure changes the relative orientation of the layer interfaces towards the stress-wedged geometry. The characterization at ESRF beamline ID13 at a photon energy of 10.5 keV demonstrated a nearly diffraction-limited focusing to a clean spot of 43 nm × 44 nm without significant side lobes with two wedged crossed MLLs using an illuminated aperture of approximately 17 µm × 17 µm to eliminate aberrations originating from layer placement errors in the full 52.7 µm × 52.7 µm aperture. These MLLs have an average individual diffraction efficiency of 44.5%. Scanning transmission X-ray microscopy measurements with convenient working distances were performed to demonstrate that the lenses are suitable for user experiments. Also discussed are the diffraction and focusing properties of crossed flat lenses made from the same deposition, which have been used as a reference. Here a focal spot size of 28 nm × 33 nm was achieved and significant side lobes were noticed at an illuminated aperture of approximately 23 µm × 23 µm.

3.
J Synchrotron Radiat ; 21(Pt 5): 1122-7, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25178001

RESUMO

Two different multilayer Laue lens designs were made with total deposition thicknesses of 48 µm and 53 µm, and focal lengths of 20.0 mm and 12.5 mm at 20.0 keV, respectively. From these two multilayer systems, several lenses were manufactured for one- and two-dimensional focusing. The latter is realised with a directly bonded assembly of two crossed lenses, that reduces the distance between the lenses in the beam direction to 30 µm and eliminates the necessity of producing different multilayer systems. Characterization of lens fabrication was performed using a laboratory X-ray microscope. Focusing properties have been investigated using ptychography.

4.
Opt Express ; 22(17): 20008-13, 2014 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-25321210

RESUMO

We demonstrate full-field X-ray microscopy using crossed multilayer Laue lenses (MLL). Two partial MLLs are prepared out of a 48 µm high multilayer stack consisting of 2451 alternating zones of WSi2 and Si. They are assembled perpendicularly in series to obtain two-dimensional imaging. Experiments are done in a laboratory X-ray microscope using Cu-Kα radiation (E = 8.05 keV, focal length f = 8.0 mm). Sub-100 nm resolution is demonstrated without mixed-order imaging at an appropriate position of the image plane. Although existing deviations from design parameters still cause aberrations, MLLs are a promising approach to realize hard X-ray microscopy at high efficiencies with resolutions down to the sub-10 nm range in future.

5.
Opt Express ; 22(14): 16676-85, 2014 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-25090486

RESUMO

A nano-focusing module based on two linear Fresnel zone plates is presented. The zone plates are designed to generate a kinoform phase profile in tilted geometry, thus overcoming the efficiency limitations of binary diffractive structures. Adjustment of the tilt angle enables tuning of the setup for optimal efficiency over a wide range of photon energies, ranging from 5 to 20 keV. Diffraction efficiency of more than 50% was measured for the full module at 8 keV photon energy. A diffraction limited spot size of 100 nm was verified by ptychographic reconstruction for a lens module with a large entrance aperture of 440 µm × 400 µm.

6.
Opt Express ; 21(7): 8051-61, 2013 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-23571895

RESUMO

Focusing hard x-ray free-electron laser radiation with extremely high fluence sets stringent demands on the x-ray optics. Any material placed in an intense x-ray beam is at risk of being damaged. Therefore, it is crucial to find the damage thresholds for focusing optics. In this paper we report experimental results of exposing tungsten and diamond diffractive optics to a prefocused 8.2 keV free-electron laser beam in order to find damage threshold fluence levels. Tungsten nanostructures were damaged at fluence levels above 500 mJ/cm(2). The damage was of mechanical character, caused by thermal stress variations. Diamond nanostructures were affected at a fluence of 59 000 mJ/cm(2). For fluence levels above this, a significant graphitization process was initiated. Scanning Electron Microscopy (SEM) and µ-Raman analysis were used to analyze exposed nanostructures.


Assuntos
Diamante/química , Diamante/efeitos da radiação , Lasers , Lentes , Refratometria/instrumentação , Tungstênio/química , Tungstênio/efeitos da radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Raios X
7.
Opt Lett ; 37(24): 5046-8, 2012 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-23258000

RESUMO

We demonstrate the use of the classical Ronchi test to characterize aberrations in focusing optics at a hard x-ray free-electron laser. A grating is placed close to the focus and the interference between the different orders after the grating is observed in the far field. Any aberrations in the beam or the optics will distort the interference fringes. The method is simple to implement and can provide single-shot information about the focusing quality. We used the Ronchi test to measure the aberrations in a nanofocusing Fresnel zone plate at the Linac Coherent Light Source at 8.194 keV.


Assuntos
Algoritmos , Análise de Falha de Equipamento/instrumentação , Lasers , Lentes , Nanotecnologia/instrumentação , Refratometria/instrumentação , Elétrons , Análise de Falha de Equipamento/métodos , Luz , Nanotecnologia/métodos , Refratometria/métodos , Espalhamento de Radiação , Raios X
8.
Opt Express ; 19(17): 16324-9, 2011 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-21934996

RESUMO

Scanning coherent diffraction microscopy (ptychography) is an emerging hard x-ray microscopy technique that yields spatial resolutions well below the lateral size of the probing nanobeam. Besides a high resolution image of the object, the complex wave field of the probe can be reconstructed at the position of the object. By verifying the consistency of several independent wave field measurements along the optical axis, we address the question of how well the reconstruction represents the nanobeam. With a single ptychogram the wave field can be properly determined over a large range along the optical axis, also at positions inaccessible otherwise.

9.
Ultramicroscopy ; 173: 52-57, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27912167

RESUMO

In recent years, X-ray ptychography has been established as a valuable tool for high-resolution imaging. Nevertheless, the spatial resolution and sensitivity in coherent diffraction imaging are limited by the signal that is detected over noise and over background scattering. Especially, coherent imaging of weakly scattering specimens suffers from incoherent background that is generated by the interaction of the central beam with matter along its propagation path in particular close to and inside of the detector. Common countermeasures entail evacuated flight tubes or detector-side beamstops, which improve the experimental setup in terms of background reduction or better coverage of high dynamic range in the diffraction patterns. Here, we discuss an alternative approach: we combine two ptychographic scans with and without beamstop and reconstruct them simultaneously taking advantage of the complementary information contained in the two scans. We experimentally demonstrate the potential of this scheme for hard X-ray ptychography by imaging a weakly scattering object composed of catalytic nanoparticles and provide the analysis of the signal-to-background ratio in the diffraction patterns.

10.
ACS Nano ; 10(3): 3553-61, 2016 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-26905642

RESUMO

In recent years, X-ray imaging of biological cells has emerged as a complementary alternative to fluorescence and electron microscopy. Different techniques were established and successfully applied to macromolecular assemblies and structures in cells. However, while the resolution is reaching the nanometer scale, the dose is increasing. It is essential to develop strategies to overcome or reduce radiation damage. Here we approach this intrinsic problem by combing two different X-ray techniques, namely ptychography and nanodiffraction, in one experiment and on the same sample. We acquire low dose ptychography overview images of whole cells at a resolution of 65 nm. We subsequently record high-resolution nanodiffraction data from regions of interest. By comparing images from the two modalities, we can exclude strong effects of radiation damage on the specimen. From the diffraction data we retrieve quantitative structural information from intracellular bundles of keratin intermediate filaments such as a filament radius of 5 nm, hexagonal geometric arrangement with an interfilament distance of 14 nm and bundle diameters on the order of 70 nm. Thus, we present an appealing combined approach to answer a broad range of questions in soft-matter physics, biophysics and biology.


Assuntos
Queratinas/ultraestrutura , Linhagem Celular , Humanos , Filamentos Intermediários/ultraestrutura , Queratinas/análise , Nanoestruturas/química , Difração de Raios X/métodos , Raios X
11.
Sci Rep ; 5: 11089, 2015 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-26086176

RESUMO

The advent of hard x-ray free-electron lasers (XFELs) has opened up a variety of scientific opportunities in areas as diverse as atomic physics, plasma physics, nonlinear optics in the x-ray range, and protein crystallography. In this article, we access a new field of science by measuring quantitatively the local bulk properties and dynamics of matter under extreme conditions, in this case by using the short XFEL pulse to image an elastic compression wave in diamond. The elastic wave was initiated by an intense optical laser pulse and was imaged at different delay times after the optical pump pulse using magnified x-ray phase-contrast imaging. The temporal evolution of the shock wave can be monitored, yielding detailed information on shock dynamics, such as the shock velocity, the shock front width, and the local compression of the material. The method provides a quantitative perspective on the state of matter in extreme conditions.

12.
Sci Rep ; 3: 1633, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23567281

RESUMO

The emergence of hard X-ray free electron lasers (XFELs) enables new insights into many fields of science. These new sources provide short, highly intense, and coherent X-ray pulses. In a variety of scientific applications these pulses need to be strongly focused. In this article, we demonstrate focusing of hard X-ray FEL pulses to 125 nm using refractive x-ray optics. For a quantitative analysis of most experiments, the wave field or at least the intensity distribution illuminating the sample is needed. We report on the full characterization of a nanofocused XFEL beam by ptychographic imaging, giving access to the complex wave field in the nanofocus. From these data, we obtain the full caustic of the beam, identify the aberrations of the optic, and determine the wave field for individual pulses. This information is for example crucial for high-resolution imaging, creating matter in extreme conditions, and nonlinear x-ray optics.

13.
Nanoscale Res Lett ; 7(1): 553, 2012 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-23039065

RESUMO

: An enhancement on the method of X-ray diffraction simulations for applications using nanofocused hard X-ray beams is presented. We combine finite element method, kinematical scattering calculations, and a spot profile of the X-ray beam to simulate the diffraction of definite parts of semiconductor nanostructures. The spot profile could be acquired experimentally by X-ray ptychography. Simulation results are discussed and compared with corresponding X-ray nanodiffraction experiments on single SiGe dots and dot molecules.

14.
Langmuir ; 25(13): 7241-3, 2009 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-19499917

RESUMO

We combine grazing-incidence small-angle X-ray scattering (GISAXS) with scanning X-ray microtomography to investigate the nanostructure in a dried gold/polystyrene nanocomposite drop. Local GISAXS structure factors are reconstructed at each position on the surface of this two-dimensionally heterogeneous sample with 30 microm pixel size. Evidence for four types of self-assembled colloidal crystalline structures is provided by the reconstructed data of the drop demonstrating the feasibility of the method.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA