Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Orthop Sci ; 24(1): 128-135, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30322622

RESUMO

PURPOSE: Several navigation-based kinematic studies of the knee have been published recently, but little information is available about reproducibility and reliability of the acquired data. The aim of the present study first is to determine reproducibility and reliability of kinematical measurements of healthy knees and knees after TKA (total knee arthroplasty) with regards to rotational and translational measurement parameters. Second the mathematical background, applicability, and limitations of investigating navigation-based kinematics should be compiled. METHODS: Using cadavers fixed by the Thiel method, in ten knees reproducibility of obtained angular and translational kinematic parameters were investigated before and after total knee arthroplasty. For this reason agreement of obtained data of a first and a second movement cycle and the same after a surgical intervention was assessed using a commercially available navigational device. RESULTS: For both angular and translational parameters in healthy knees and knees after total knee arthroplasty mean differences between measured parameters of the first and second movement cycle and after surgical intervention of less than 0.5° or millimeters (standard deviation 1.3 or less) or a inter class correlation of 0.92 and more, respectively, was found. DISCUSSION: Use of a commercial navigation system allows highly accurate investigations of knee kinematics in cadavers before and after TKA. This technique, which does not require any specific technical knowledge of the investigator, is in accordance with current accepted biomechanical methods.


Assuntos
Articulação do Joelho/fisiopatologia , Osteoartrite do Joelho/diagnóstico por imagem , Amplitude de Movimento Articular/fisiologia , Idoso , Artroplastia do Joelho , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Masculino , Osteoartrite do Joelho/fisiopatologia , Reprodutibilidade dos Testes
2.
Int Orthop ; 41(10): 2037-2044, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28550426

RESUMO

PURPOSE: Our aim was to compare the long-term outcome between navigated and conventional total knee arthroplasty (TKA), which is currently not known. METHODS: Long-term survivorship, clinical scores and radiographic results of a matched-pair group of 350 patients (350 knees) treated with navigated (n = 157) or conventional (n = 188) TKA for osteoarthritis over a period of 11 years were reviewed retrospectively. RESULTS: The mean clinical follow-up was ten years. There were no clinically relevant differences with respect to any clinical outcome, patient satisfaction or pain between the two groups. Coronal leg alignment was closer (1.7-3.1°) to the neutral mechanical axis in the navigated group compared with the conventional group (2.6-4.7°). A total of 12 knees (6.4%) in the conventional group and three (1.9%) in the navigated group underwent revision surgery (p = 0.04), resulting in an absolute risk reduction of 4.5% for revision surgery by using navigation. Using any revision as an end point, the ten-year Kaplan-Meier survivorship was 98.1% in the navigated and 92.5% in the conventional group. CONCLUSIONS: Navigated TKA improves implant survivorship compared with conventional TKA.


Assuntos
Artroplastia do Joelho/métodos , Osteoartrite do Joelho/cirurgia , Cirurgia Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Masculino , Análise por Pareamento , Pessoa de Meia-Idade , Osteoartrite do Joelho/mortalidade , Satisfação do Paciente/estatística & dados numéricos , Falha de Prótese , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Análise de Sobrevida , Sobrevivência , Resultado do Tratamento
3.
Knee Surg Sports Traumatol Arthrosc ; 24(8): 2407-14, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25399346

RESUMO

PURPOSE: Component malrotation has a major impact on patellar kinematics in total knee arthroplasty. The influence of natural rotational limb alignment on patellar kinematics is unclear so far. Based on recent clinical investigations, we hypothesized that rotational limb alignment significantly influences patellar kinematics. METHODS: Patellar kinematics of ten cadaveric knees was measured using computer navigation during passive motion. Data were correlated with different rotational limb alignment parameters of preoperative CT scans. RESULTS: Femoral antetorsion showed a significant influence on patellar rotation, while tibial tubercle-posterior cruciate ligament distance additionally displayed a significant influence on patellar mediolateral shift (p < 0.05). Femoral posterior condylar angle was sensitive to patellar epicondylar distance, rotation and tilt (p < 0.05). Patellar rotation was influenced by five out of eight rotational limb alignment parameters (p < 0.05). CONCLUSIONS: Rotational limb alignment should be paid more attention in terms of clinical evaluation of patellar tracking and future biomechanical and clinical investigations.


Assuntos
Artroplastia do Joelho , Mau Alinhamento Ósseo , Patela/fisiologia , Rotação , Idoso , Fenômenos Biomecânicos , Feminino , Fêmur/cirurgia , Humanos , Técnicas In Vitro , Joelho/cirurgia , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia , Patela/cirurgia , Ligamento Cruzado Posterior/cirurgia , Amplitude de Movimento Articular , Tíbia/cirurgia , Tomografia Computadorizada por Raios X
4.
Knee Surg Sports Traumatol Arthrosc ; 24(3): 823-9, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26820967

RESUMO

PURPOSE: Patellar maltracking due to incorrect component alignment is considered as a main reason for anterior knee pain after total knee arthroplasty (TKA). In contrast to coronal and axial component placement, the influence of sagittal component alignment on patellar kinematics has not been investigated so far. METHODS: In ten lower cadaveric limbs, TKAs were implanted using a commercial computer navigation system. In six knees, the femoral component was aligned in 5° and in four knees in 0° of flexion, respectively. Patellar kinematics were registered by means of a computer navigation system using an additional patella tracking array and correlated with femoral and tibial sagittal component alignment. RESULTS: Sagittal component alignment significantly altered patellar mediolateral shift (p < 0.05). In contrast, patellar epicondylar distance, rotation and tilt were not significantly influenced. CONCLUSIONS: Sagittal component alignment in TKA has a major impact on patellar kinematics and should therefore be considered while addressing tibiofemoral kinematics intraoperatively.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Patela/fisiologia , Ajuste de Prótese , Fenômenos Biomecânicos/fisiologia , Cadáver , Humanos , Modelos Lineares , Cirurgia Assistida por Computador
5.
Knee Surg Sports Traumatol Arthrosc ; 24(8): 2453-60, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25682166

RESUMO

PURPOSE: The intraoperative sagittal cutting block alignment when intramedullary alignment rods are used was investigated. Its absolute orthogonal orientation in relation to the mechanical femoral axis should be analysed. It was hypothesized that (1) alignment rods do not ensure a desired deviation within a range between 0° and 3° flexion as it has been shown to be favourable for clinical and functional outcome. Further, the degree of flexion cannot be (2) foreseen by the surgeon or (3) estimated by clinical or radiological parameters. METHODS: Forty knees allocated to total knee arthroplasty were included. The distal femoral cutting block was aligned using an intramedullary rod. By means of a navigation device, the sagittal alignment of the cutting block in degrees of flexion was measured. RESULTS: The mean measured flexion of the cutting block was 4.4° (3.6 SD). Twenty-five per cent (10/40) of the values were within a corridor between 0° and 3° of flexion. The mean difference between expected and measured flexion was -1.5° (-7.6 to 4.7 95 % limits of agreement). The dorsoventral diameter of the distal femur showed a significant influence on measured flexion (R (2) = 0.112, p = 0.035). CONCLUSION: Intramedullary alignment rods used in the present study do not ensure a distal cutting block alignment between 0° and 3° of flexion in relation to the femoral mechanical axis. The extent of flexion could not be foreseen either by the surgeon. The dorsoventral diameter of the distal femur correlated with measured flexion. However, only limited data is available on influence of femoral component flexion on implant failure or clinical and functional outcome. LEVEL OF EVIDENCE: Diagnostic study, Level II.


Assuntos
Artroplastia do Joelho/métodos , Mau Alinhamento Ósseo , Fêmur/cirurgia , Fixadores Internos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Amplitude de Movimento Articular
6.
Int Orthop ; 40(12): 2495-2504, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27106215

RESUMO

PURPOSE: In this prospective study of 135 patients undergoing cementless total hip arthroplasty (THA) we asked whether six current definitions of combined anteversion prevent impingement and increase postoperative patient individual impingement-free range-of-motion (ROM). METHODS: Implant position was measured by an independent, external institute on 3D-CT performed six weeks post-operatively. Post-operative ROM was calculated using a CT-based algorithm detecting osseous and/or prosthetic impingement by virtual hip movement. Additionally, clinical ROM was evaluated pre-operatively and one-year post-operatively by a blinded observer. RESULTS: Combined component position of cup and stem according to the definitions of Ranawat, Widmer, Dorr, Hisatome and Yoshimine inhibited prosthetic impingement in over 90 %, while combined osseous and prosthetic impingement still occurred in over 40 % of the cases. The recommendations by Jolles, Widmer, Dorr, Yoshimine and Hisatome enabled higher flexion (p ≤ 0.001) and internal rotation (p ≤ 0.006). Clinically, anteversion rules of Widmer and Yoshimine provided one-year post-operatively statistically but not clinically relevant higher internal rotation (p ≤0.034). CONCLUSION: Standard rules of combined anteversion detect prosthetic but fail to prevent combined osseous and prosthetic impingement in THA. Future models will have to account for the patient-individual anatomic situation to ensure impingement-free ROM.


Assuntos
Artroplastia de Quadril/normas , Articulação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Idoso , Artroplastia de Quadril/efeitos adversos , Feminino , Articulação do Quadril/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Artropatias/diagnóstico por imagem , Artropatias/etiologia , Artropatias/prevenção & controle , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Amplitude de Movimento Articular , Rotação , Técnicas Estereotáxicas , Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X
7.
Int Orthop ; 40(4): 673-80, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26728611

RESUMO

PURPOSE: This study investigated whether etoricoxib (COX-II blocker) has a superior efficacy of preventing heterotopic ossification (HO) after total hip arthroplasty (THA) compared to diclofenac (non-selective NSAID). METHODS: One hundred patients were included (50 in each group) in this single centre, prospective, double-blinded, randomized, controlled trial. Etoricoxib (90 mg) was administered once and diclofenac (75 mg) twice per day for a perioperative period of nine days. The incidence of HO was evaluated on radiographs of the pelvis six months after surgery. RESULTS: Eighty nine of 100 (89 %) patients could be analysed. The overall HO incidence was 37.8 %. There was no significant difference between both study groups. Twelve patients (27.3 %) of the DIC group and 13 patients (28.9 %) of the ETO group showed Brooker grade I ossifications. Five patients (11.4 %) of the DIC and four patients of the ETO (8.9 %) group showed grade II HO formations. No class III or IV HO formations occured in both groups. Ad hoc analysis detected a negative correlation between HO incidence and limited abduction and internal rotation of the hip. CONCLUSIONS: Etoricoxib and diclofenac are equally effective for oral HO prophylaxis after primary cementless THA when given for nine peri-operative days to ensure a full recovery and high patient satisfaction.


Assuntos
Anti-Inflamatórios não Esteroides/uso terapêutico , Artroplastia de Quadril/efeitos adversos , Inibidores de Ciclo-Oxigenase 2/uso terapêutico , Diclofenaco/uso terapêutico , Ossificação Heterotópica/prevenção & controle , Piridinas/uso terapêutico , Sulfonas/uso terapêutico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Anti-Inflamatórios não Esteroides/efeitos adversos , Inibidores de Ciclo-Oxigenase 2/efeitos adversos , Diclofenaco/efeitos adversos , Método Duplo-Cego , Etoricoxib , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Ossificação Heterotópica/etiologia , Pelve/diagnóstico por imagem , Pelve/patologia , Período Perioperatório , Estudos Prospectivos , Piridinas/efeitos adversos , Sulfonas/efeitos adversos
8.
Arch Orthop Trauma Surg ; 136(5): 709-13, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26891850

RESUMO

INTRODUCTION: Trabecular properties in osteonecrosis of the femoral head (ONFH) are altered for bone volume and structure in the femoral head and proximal femoral canal. We analysed the periprosthetic bone mineral density (BMD) as a correlate to bony ingrowth in patients with ONFH who received a cementless THA. MATERIALS AND METHODS: We performed a matched-pair analysis of 100 patients with ONFH (n = 50) and primary osteoarthritis (n = 50) who received the same, unilateral cementless THA. We compared the periprosthetic BMD 5 years after surgery by means of dual energy X-ray absorptiometry (DXA) analysing the seven femoral regions of interest (ROIs) according to Gruen. RESULTS: Within the ONFH group, significantly lower BMD values were found in the ROI 1 and 7 (p < 0.05). No statistically significant difference was found for ROIs 2-6. CONCLUSIONS: An altered periprosthetic bone stock in the proximal femur in patients with prior ONFH might be a possible risk factor for premature loosening of the femoral stem in THA. Surgeons need to consider coating and fixation philosophy of cementless implants when choosing the right stem for patients with ONFH.


Assuntos
Artroplastia de Quadril/métodos , Densidade Óssea , Necrose da Cabeça do Fêmur/cirurgia , Fêmur/fisiopatologia , Fêmur/cirurgia , Osteoartrite do Quadril/cirurgia , Absorciometria de Fóton , Idoso , Artroplastia de Quadril/efeitos adversos , Doenças Ósseas Metabólicas , Feminino , Fêmur/diagnóstico por imagem , Cabeça do Fêmur/cirurgia , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Necrose da Cabeça do Fêmur/fisiopatologia , Seguimentos , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/fisiopatologia , Complicações Pós-Operatórias
9.
Brain Behav Immun ; 46: 180-91, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25736064

RESUMO

OBJECTIVE: Density of sympathetic nerve fibers decreases in inflamed arthritic tissue tested by immunoreactivity towards tyrosine-hydroxylase (TH, catecholaminergic key enzyme). Since sympathetic nerve fibers may change phenotype from catecholaminergic to cholinergic (example: sweat glands), loss of nerve fibers may relate to undetectable TH. We aimed to investigate possible catecholaminergic-to-cholinergic transition of sympathetic nerve fibers in synovial tissue of animals with arthritis, and patients with rheumatoid arthritis (RA) and osteoarthritis (OA), and we wanted to find a possible transition factor. METHODS: Nerve fibers were detected by immunofluorescence towards TH (catecholaminergic) and vesicular acetylcholine transporter (cholinergic). Co-culture experiments with sympathetic ganglia and lymphocytes or osteoclast progenitors were designed to find stimulators of catecholaminergic-to-cholinergic transition (including gene expression profiling). RESULTS: In mouse joints, an increased density of cholinergic relative to catecholaminergic nerve fibers appeared towards day 35 after immunization, but most nerve fibers were located in healthy joint-adjacent skin or muscle and almost none in inflamed synovial tissue. In humans, cholinergic fibers are more prevalent in OA synovial tissue than in RA. Co-culture of sympathetic ganglia with osteoclast progenitors obtained from healthy but not from arthritic animals induced catecholaminergic-to-cholinergic transition. Osteoclast mRNA microarray data indicated that leukemia inhibitory factor (LIF) is a candidate transition factor, which was confirmed in ganglia experiments, particularly, in the presence of progesterone. CONCLUSION: In humans and mice, catecholaminergic-to-cholinergic sympathetic transition happens in less inflamed tissue but not in inflamed arthritic tissue. Under healthy conditions, presence of cholinergic sympathetic nerve fibers may support the cholinergic anti-inflammatory influence recently described.


Assuntos
Acetilcolina/metabolismo , Fibras Adrenérgicas/metabolismo , Artrite Reumatoide/metabolismo , Catecolaminas/metabolismo , Osteoartrite/metabolismo , Animais , Humanos , Masculino , Camundongos , Sistema Nervoso Simpático/metabolismo , Membrana Sinovial
10.
BMC Musculoskelet Disord ; 16: 313, 2015 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-26494270

RESUMO

BACKGROUND: Heterotopic ossification (HO) is a complication after tissue trauma, fracture and surgery (i.e. total hip arthroplasty). Prophylaxis is the most effective therapy. If HO formations become symptomatic and limit patients' quality of life, revision surgery is indicated and is usually combined with a perioperative oral prophylaxis (NSAIDs) and/or irradiation. However, a long-term use of NSAIDs can induce gastro-intestinal or cardiac side-effects and possible bony non-unions during fracture healing. Subject of this study was to assess the current status of HO prophylaxis after injuries or fractures and to evaluate current indications and strategies for excision of symptomatic HO. METHODS: Between 2013 and 2014, a questionnaire was sent to 119 orthopaedic and trauma surgery departments in Germany. Participation was voluntary and all acquired data was given anonymously. RESULTS: The cumulative feedback rate was 71 %. Trauma and orthopaedic surgery departments in Germany recommend oral HO prophylaxis after acetabulum and femoral neck fractures, elbow dislocation, and fracture or dislocation of the radial head. Pain upon movement and an increasing loss of range of motion in the affected joint are considered to be clear indications for HO surgery. A partial removal of ROM-limiting HO formations was also considered important. The vast majority of all departments include perioperative oral HO prophylaxis and/or irradiation if surgical HO removal is planned. The choice and duration of NSAIDs is highly variable. CONCLUSION: HO is of clinical significance in current traumatology and orthopaedics. Certain fractures and injuries are prone to HO, and prophylactic measures should be taken. The respondents in this survey assessed current therapeutic strategies for HO formations similarly. These concepts are in line with the literature. However, the duration of perioperative oral HO prophylaxis varied greatly among the specialist centres. This is significant as a long-term use of NSAIDs fosters a potential risk for the patients' safety and could influence the clinical outcome. National and international guidelines need to be developed to further reduce HO rates and improve patients' safety in trauma and orthopaedic surgery.


Assuntos
Ossificação Heterotópica/prevenção & controle , Humanos , Ortopedia/estatística & dados numéricos , Inquéritos e Questionários , Centros de Traumatologia/estatística & dados numéricos
11.
Knee Surg Sports Traumatol Arthrosc ; 23(6): 1591-7, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24888221

RESUMO

PURPOSE: The purpose of this prospective, randomised, double-blind study was to test the hypotheses that patients with high-flexion total knee arthroplasty (TKA) have (1) a wider/greater range of motion (ROM) post-operatively and (2) higher levels of knee society score (KSS) and WOMAC score post-operatively compared to standard TKA. METHODS: In this study, 28 high flexion with 31 standard TKAs were compared. We measured ROM, pre-operatively, on day 3, 7, 28, and after 6 and 36 months post-operatively as well as KSS and WOMAC score pre-operatively, on day 28 and after 6 and 36 months post-operatively. RESULTS: No statistically significant differences were found between both groups with regard to the target parameters. The mean ROM was 113° (range 80°-140°, SD 13.4°) in the control group (standard TKA) and 117° (range 90°-140°, SD 12.3) in the study group (high-flexion TKA) at 36 months follow-up [p = not significant (n.s.)]. The KSS pre-operatively was 38.2 (range 8-64, SD 15.8) in the control group and 45.9 (range 8-74, SD 16.0) in the study group (n.s.) increasing to 157.6 in the control group and 156.7 in the study group (p = n.s) at 36 months follow-up. CONCLUSION: This study could not confirm significant benefits of high-flexion TKA compared to standard TKA with regard to ROM and higher levels of KSS and WOMAC score. LEVEL OF EVIDENCE: I.


Assuntos
Artroplastia do Joelho/métodos , Prótese do Joelho , Avaliação de Resultados da Assistência ao Paciente , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/instrumentação , Método Duplo-Cego , Feminino , Humanos , Articulação do Joelho/fisiopatologia , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Amplitude de Movimento Articular/fisiologia
12.
Int Orthop ; 39(3): 455-60, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25242460

RESUMO

PURPOSE: Restoring a neutral mechanical axis in total knee arthroplasty (TKA) (within ±3° of varus/valgus) is associated with superior functional outcome and reduced early implant failure. Using conventional alignment jigs results in malalignment in >20 % of cases. In this study, we investigated the reduction of outliers within the threshold of ±3° of leg alignment using a "pinless" navigation system in comparison with conventional alignment jigs investigated. METHODS: In this randomised prospective study, 80 patients were randomly assigned/allocated to the pinless or conventional control group. After surgery, the two groups were compared regarding outliers > ±3° by means of hip-knee-ankle angle (HKA), mechanical medial proximal tibia angle (mMPTA), mechanical lateral distal femoral angle (mLDFA) and duration of surgery. Student's unpaired t test was used for quantitative variables, Fisher's exact test compared groups (pinless vs. control) and a two-sided p value of ≤0.05 was considered statistically significant. RESULTS: In the pinless group, outliers regarding HKA and mLDFA > ±3° was significantly reduced (p = 0.025 and p = 0.002 respectively). In the pinless group, the surgery duration was significantly longer (75.6 vs. 64.5 minutes, p < 0.001). CONCLUSION: Pinless navigation is effective in reducing outliers > ±3° regarding HKA without risking pin-related complications, such as fractures, infections or breaking screws. However, not all tools for conventional navigation in TKA, such as real-time measurements of the tibiofemoral axis and gap balancing, are available.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Cirurgia Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Fêmur/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tíbia/cirurgia
13.
Knee Surg Sports Traumatol Arthrosc ; 22(12): 2982-8, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25253236

RESUMO

PURPOSE: Rotation of the lower limbs in long-leg radiographs has a significant impact on imaging the mechanical femorotibial angle, the femoral anatomic mechanical angle, the mechanical lateral distal femoral angle (mLDFA) and the mechanical medial proximal tibial angle (mMPTA). In this study, we assessed the rotation of the lower limbs in conventional radiographs and hypothesized that the relative position of the proximal fibula to the proximal tibia on long-leg radiographs is related to the rotation of the knee joint. METHODS: Radiological examinations in different rotational positions of the knee joint (incremental 40° internal to 40° external rotation) were imitated by 50 computed tomography scans (50 patients, 25 men and 25 women). The extent of the projection overlaps of the fibula, the fibular tip and the distance from the fibular tip to the lateral cortex were determined for every rotational position. RESULTS: Multiple regression analysis showed a very strong correlation between the measured fibular parameters and knee rotation between 20° of internal rotation and 40° of external rotation (R (2) ~ 0.94, p < 0.001). By means of these results, we created a formula for predicting knee rotation: [Formula: see text]This strong correlation could not be found between 20° and 40° of internal rotation. DISCUSSION: Because incorrect internal and external rotation negatively influence the correct measurement of angles (mechanical femorotibial angle, femoral anatomic mechanical angle, the mLDFA and the mMPTA), long-leg radiographs should be assessed for proper rotation angles before measurement. Using the provided formula rotation of the lower limb in weight-bearing, long-leg radiographs can be reliably predicted. LEVEL OF EVIDENCE: Diagnostic study, Level II.


Assuntos
Fíbula/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/diagnóstico por imagem , Tíbia/diagnóstico por imagem , Idoso , Feminino , Fêmur/diagnóstico por imagem , Humanos , Extremidade Inferior/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Rotação
14.
J Arthroplasty ; 29(8): 1661-5, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24857334

RESUMO

Successful biomechanical reconstruction is a major goal in total hip arthroplasty (THA). We measured leg length (LL), global (GO) and femoral offset (FO) change on anteroposterior pelvis radiographs and on three-dimensional computed-tomography (3D-CT) with fiducial landmarks after cementless THA on 18 hips of cadaveric specimens. Measurements on radiographs were performed twice by four examiners and showed high interobserver (mean CCC ≥0.79) and intraobserver agreements (mean ICC ≥0.88). Mean differences between radiographic and 3D-CT measurements were 1.0 (SD 2.0) mm for LL, 0.6 (SD 3.6) mm for GO and 1.4 (SD 5.2) mm for FO. 1% of radiographic LL-, 15% of GO- and 35% of FO measurements were outside a tolerance limit of 5mm. Radiographs seem acceptable for measuring LL/GO change but fail to reflect FO change in THA.


Assuntos
Artrografia/normas , Artroplastia de Quadril/métodos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Tomografia Computadorizada por Raios X/normas , Artrografia/métodos , Artrografia/estatística & dados numéricos , Cadáver , Marcadores Fiduciais , Humanos , Imageamento Tridimensional/métodos , Imageamento Tridimensional/normas , Imageamento Tridimensional/estatística & dados numéricos , Variações Dependentes do Observador , Pelve/diagnóstico por imagem , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/estatística & dados numéricos
15.
J Arthroplasty ; 29(11): 2197-201, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25108734

RESUMO

Despite different surgical patellar interventions, the decision how to treat the patella during TKA remains controversial. The purpose of this study was to quantify the effect of different reconstructive patellar interventions on patellar kinematics during TKA using optical computer navigation. We implanted ten navigated TKAs in full body specimens. During passive motion, the effect of different surgical patellar interventions on patellar kinematics was analysed. A contrarily tilt behaviour was observed in the TKA group without patellar intervention compared to the natural knee. Lateral release led to similar tilt values (P < 0.05). All surgical interventions led to a 3 to 5mm medial shift of the patella (P < 0.05). None of the analysed surgical patellar interventions could restore natural patellar kinematics after TKA.


Assuntos
Artroplastia do Joelho/métodos , Patela/cirurgia , Idoso , Fenômenos Biomecânicos , Cadáver , Humanos , Articulação do Joelho/fisiopatologia , Articulação do Joelho/cirurgia , Prótese do Joelho , Masculino , Patela/fisiopatologia , Amplitude de Movimento Articular , Cirurgia Assistida por Computador
16.
Int Orthop ; 38(6): 1173-81, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24570152

RESUMO

PURPOSE: Restoring the joint line (JL) improves clinical and functional outcome in total knee arthroplasty (TKA). Therefore, anatomical landmarks to approximate the JL have been published. So far, the natural deviation of the JL 90° to the mechanical tibial axis has not been considered. Thus, we designed this study to: (1) determine the natural JL of knees in healthy persons in respect to the mechanical tibial axis, (2) validate and double-check intra-operative bony landmarks already been published in respect to the natural JL and (3) find possible correlations between distances from bony landmarks to the JL and femoral and tibial width. METHODS: Eighty MRI scans of knees of healthy persons were examined by two independent observers. Distances from the tip of the fibular head (FH), the medial (ME) and lateral (LE) epicondyles and the adductor tubercle (AT) to the JL within the medial and lateral compartment were measured. Further, we determined the orientation of the JL in respect to the mechanical axis of the tibia. Interobserver correlations were calculated. Differences were analyzed using Student's t test. Linear regression models were calculated to analyze correlations. RESULTS: Interobserver correlation was excellent. Mean JL deviation was 4.2° varus. Distance between the FH, ME, LE and AT to the JL within the medial compartment was 12.2, 33.9, 33.4 and 45.4 mm, respectively. Within in the lateral compartment, distances were 15.3, 31.0, 30.6 and 42.3 mm to the JL. Strong correlation was found between femoral width and distances from the AT, ME and LE to the JL. CONCLUSION: In TKA, the JL is usually altered due to the classic resection technique, which does not respect the natural deviation of the JL. Estimating the natural JL by adding absolute values to bony landmarks, as proposed in the literature, is not recommended. According to our data, the JL can be best estimated by adding the calculated value: 6.40 + (width femur [mm] × 0.49) to the AT.


Assuntos
Traumatismos do Joelho/diagnóstico , Articulação do Joelho , Ligamentos Articulares/lesões , Imageamento por Ressonância Magnética , Lesões do Menisco Tibial , Adulto , Feminino , Fêmur , Humanos , Traumatismos do Joelho/cirurgia , Ligamentos Articulares/cirurgia , Masculino , Meniscos Tibiais/cirurgia , Tíbia
17.
J Clin Med ; 13(13)2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38999284

RESUMO

Background: Periprosthetic joint infection (PJI) following total knee arthroplasty is a serious complication lacking evidence-based diagnostic and treatment protocols, particularly in ruling out persisting infection before reimplantation. Methods: This retrospective analysis assessed the mid-term outcomes of 66 patients undergoing septic two-stage knee revision surgeries from 2007 to 2013, diagnosed as per the Musculoskeletal Infection Society criteria. After implant removal and antibiotic treatment, reimplantation decisions were based on either joint aspiration, blood counts, and clinical examination (group A) or an open biopsy (group B). Both groups underwent meticulous debridement and spacer exchange during the interim period. Results: Late re-infection occurred in 12.1% of all patients. In group A, 13.8% experienced late re-infection, with 14.3% in subgroup A1 and 13.3% in subgroup A2. In group B, 10% had a late re-infection. No significant difference in re-infection or complication rates was found between the groups. Conclusions: The study did not demonstrate the superiority of group B's approach of open biopsy over group A's joint aspiration, clinical examination, and blood counts in preventing re-infection or reducing complications.

18.
J Orthop Sci ; 18(6): 955-61, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24077758

RESUMO

BACKGROUND: Revision total knee arthroplasties (TKA) have been performed with increasing frequency over the last 25 years. METHODS: In this study, we retrospectively analyzed 78 patients who underwent 78 revision TKAs during the years 2003­2007 with an average follow-up of 81 months (range 60­108 months). All patients were treated with a standard rotating hinge prosthesis (TC3, DePuy, Warsaw, IN, USA) due to significant instability. We evaluated the postoperative results using the Knee Society clinical rating system and the WOMAC rating system. RESULTS: Clinical results revealed significant improvements in both scores. Complications occurred in almost one-third of the cases, with a reoperation rate of 26 %. CONCLUSION: Our mid-term findings show that revision TKAs lead to an improvement in patient-perceived outcomes of physical variables. While revision TKA is a useful option for patients, procedure-associated complications should not be neglected. During the course of the procedure, it is important to collect patient-oriented data and focus on responsive and valid scores.


Assuntos
Artroplastia do Joelho/efeitos adversos , Osteoartrite do Joelho/cirurgia , Dor Pós-Operatória/fisiopatologia , Falha de Prótese , Autoavaliação (Psicologia) , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/métodos , Estudos de Coortes , Feminino , Seguimentos , Alemanha , Humanos , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico , Medição da Dor , Satisfação do Paciente/estatística & dados numéricos , Amplitude de Movimento Articular/fisiologia , Reoperação/métodos , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
19.
Int Orthop ; 37(3): 407-14, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23361937

RESUMO

PURPOSE: Individual physiological knee kinematics are highly variable in normal knees and are altered following cruciate-substituting (PS) and cruciate-retaining (CR) total knee arthroplasty (TKA). We wanted to know whether knee kinematics are different choosing two different knee designs, CR and PS TKA, during surgery using computer navigation. METHODS: For this purpose, 60 consecutive TKA were randomised, receiving either CR (37 patients) or PS TKA (23 patients). All patients underwent computer navigation, and kinematics were assessed prior to making any cuts or releases and after implantation. Outcome measures were relative rotation between femur and tibia, measured medial and lateral gaps and medial and lateral condylar lift-off. RESULTS: We were not able to demonstrate a significant difference in femoral external rotation between either group prior to implantation (7.9° CR vs. 7.4° PS) or after implantation (9.0° CR vs. 11.3° PS), both groups showed femoral roll-back. It significantly increased pre- to postoperatively in PS TKA. In the CR group both gaps increased, the change of the medial gap was significantly attributable to medial release. In the PS group both gaps increased and the change of the medial and of the lateral gap was significant. Condylar lift-off was observed in the CR group during 20° and 60° of flexion. CONCLUSION: This study did not reveal significant differences in navigation-based knee kinematics between CR and PS implants. Femoral roll-back was observed in both implant designs, but significantly increased pre- to postoperatively in PS TKA. A slight midflexion instability was observed in CR TKA. Intra-operative computer navigation can measure knee kinematics during surgery before and after TKR implantation and may assist surgeons to optimise knee kinematics or identify abnormal knee kinematics that could be corrected with ligament releases to improve the functional result of a TKR, whether it is a CR or PS design. Our intra-operative finding needs to be confirmed using fluoroscopic or radiographic 3D matching after complete recovery from surgery.


Assuntos
Articulação do Joelho/fisiopatologia , Osteoartrite do Joelho/cirurgia , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho , Fenômenos Biomecânicos , Feminino , Fêmur/cirurgia , Humanos , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/fisiopatologia , Estudos Prospectivos , Rotação , Técnicas Estereotáxicas , Cirurgia Assistida por Computador , Tíbia/cirurgia
20.
Rheumatol Int ; 32(10): 3113-7, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21927902

RESUMO

The aim of this study was to assess the efficacy and safety of intra-articular sodium morrhuate injections in the treatment of recurrent knee joint effusions. Ninety-eight knees of 92 patients (f = 59, m = 33) with knee arthritis of heterogeneous etiology were treated with chemical synovectomy (CSO). Of those, 39 patients suffered from rheumatoid arthritis (RA). The mean follow-up was 29.8 months. Clinical outcome was evaluated by analyzing subjective patient satisfaction, activity level, pain severity on the basis of the Visual Analogue Pain Scale (VAS), Lysholm and Gillquist score, and the Knee Injury and Osteoarthritis Outcome Score (KOOS). Fifty-seven percent of all patients and 67% of patients diagnosed with RA were satisfied with CSO. No significant effects on patient satisfaction by CSO were noted in patients older than 40 years. Overall, VAS, Lysholm and Gillquist score, and KOOS improved significantly at final review. The intra-articular application of sodium morrhuate is an effective and safe measure in the treatment of recurrent symptomatic knee joint effusions in young patients suffering from recurrent knee joint effusions.


Assuntos
Artrite/tratamento farmacológico , Articulação do Joelho/efeitos dos fármacos , Morruato de Sódio/uso terapêutico , Membrana Sinovial/efeitos dos fármacos , Sinovite/tratamento farmacológico , Adolescente , Adulto , Idoso , Artralgia/etiologia , Artralgia/prevenção & controle , Artrite/diagnóstico , Artrite/fisiopatologia , Artrite Reumatoide/tratamento farmacológico , Artrite Reumatoide/patologia , Feminino , Humanos , Injeções Intra-Articulares , Articulação do Joelho/patologia , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Medição da Dor , Satisfação do Paciente , Recuperação de Função Fisiológica , Recidiva , Estudos Retrospectivos , Morruato de Sódio/administração & dosagem , Morruato de Sódio/efeitos adversos , Inquéritos e Questionários , Membrana Sinovial/patologia , Sinovite/diagnóstico , Sinovite/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA